Search NASA⌕ Search

SEARCH · Search NASA

Results for “visual tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Autonomous Rover Traverse and Precise Arm Placement on Remotely Designated Targets

This software controls a rover platform to traverse rocky terrain autonomously, plan paths, and avoid obstacles using its stereo hazard and navigation cameras. It does so while continuously tracking a target of interest selected from 10 20 m away. The rover drives and tracks the target until it reaches the vicinity of the target. The rover then positions itself to approach the target, deploys its robotic arm, and places the end effector instrument on the designated target to within 2-3-cm accuracy of the originally selected target. This software features continuous navigation in a fairly rocky field in an outdoor environment and the ability to enable the rover to avoid large rocks and traverse over smaller ones. Using point-and-click mouse commands, a scientist designates targets in the initial imagery acquired from the rover s mast cameras. The navigation software uses stereo imaging, traversability analysis, path planning, trajectory generation, and trajectory execution. It also includes visual target tracking of a designated target selected from 10 m away while continuously navigating the rocky terrain. Improvements in this design include steering while driving, which uses continuous curvature paths. There are also several improvements to the traversability analyzer, including improved data fusion of traversability maps that result from pose estimation uncertainties, dealing with boundary effects to enable tighter maneuvers, and handling a wider range of obstacles. This work advances what has been previously developed and integrated on the Mars Exploration Rovers by using algorithms that are capable of traversing more rock-dense terrains, enabling tight, thread-the-needle maneuvers. These algorithms were integrated on the newly refurbished Athena Mars research rover, and were fielded in the JPL Mars Yard. Forty-three runs were conducted with targets at distances ranging from 5 to 15 m, and a success rate of 93% was achieved for placement of the instrument within 2-3 cm of the target.

Nesnas, Issa A.↗

Mobile C-arm cone-beam CT for guidance of spine surgery: Image quality, radiation dose, and integration with interventional guidance

Purpose: A flat-panel detector based mobile isocentric C-arm for cone-beam CT (CBCT) has been developed to allow intraoperative 3D imaging with sub-millimeter spatial resolution and soft-tissue visibility. Image quality and radiation dose were evaluated in spinal surgery, commonly relying on lower-performance image intensifier based mobile C-arms. Scan protocols were developed for task-specific imaging at minimum dose, in-room exposure was evaluated, and integration of the imaging system with a surgical guidance system was demonstrated in preclinical studies of minimally invasive spine surgery. Methods: Radiation dose was assessed as a function of kilovolt (peak) (80-120 kVp) and milliampere second using thoracic and lumbar spine dosimetry phantoms. In-room radiation exposure was measured throughout the operating room for various CBCT scan protocols. Image quality was assessed using tissue-equivalent inserts in chest and abdomen phantoms to evaluate bone and soft-tissue contrast-to-noise ratio as a function of dose, and task-specific protocols (i.e., visualization of bone or soft-tissues) were defined. Results were applied in preclinical studies using a cadaveric torso simulating minimally invasive, transpedicular surgery. Results: Task-specific CBCT protocols identified include: thoracic bone visualization (100 kVp; 60 mAs; 1.8 mGy); lumbar bone visualization (100 kVp; 130 mAs; 3.2 mGy); thoracic soft-tissue visualization (100 kVp; 230 mAs; 4.3 mGy); and lumbar soft-tissue visualization (120 kVp; 460 mAs; 10.6 mGy) - each at (0.3 x 0.3 x 0.9 mm{sup 3}) voxel size. Alternative lower-dose, lower-resolution soft-tissue visualization protocols were identified (100 kVp; 230 mAs; 5.1 mGy) for the lumbar region at (0.3 x 0.3 x 1.5 mm{sup 3}) voxel size. Half-scan orbit of the C-arm (x-ray tube traversing under the table) was dosimetrically advantageous (prepatient attenuation) with a nonuniform dose distribution ({approx}2 x higher at the entrance side than at isocenter, and {approx}3-4 lower at the exit side). The in-room dose (microsievert) per unit scan dose (milligray) ranged from {approx}21 {mu}Sv/mGy on average at tableside to {approx}0.1 {mu}Sv/mGy at 2.0 m distance to isocenter. All protocols involve surgical staff stepping behind a shield wall for each CBCT scan, therefore imparting {approx}zero dose to staff. Protocol implementation in preclinical cadaveric studies demonstrate integration of the C-arm with a navigation system for spine surgery guidance-specifically, minimally invasive vertebroplasty in which the system provided accurate guidance and visualization of needle placement and bone cement distribution. Cumulative dose including multiple intraoperative scans was {approx}11.5 mGy for CBCT-guided thoracic vertebroplasty and {approx}23.2 mGy for lumbar vertebroplasty, with dose to staff at tableside reduced to {approx}1 min of fluoroscopy time ({approx}40-60 {mu}Sv), compared to 5-11 min for the conventional approach. Conclusions: Intraoperative CBCT using a high-performance mobile C-arm prototype demonstrates image quality suitable to guidance of spine surgery, with task-specific protocols providing an important basis for minimizing radiation dose, while maintaining image quality sufficient for surgical guidance. Images demonstrate a significant advance in spatial resolution and soft-tissue visibility, and CBCT guidance offers the potential to reduce fluoroscopy reliance, reducing cumulative dose to patient and staff. Integration with a surgical guidance system demonstrates precise tracking and visualization in up-to-date images (alleviating reliance on preoperative images only), including detection of errors or suboptimal surgical outcomes in the operating room.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using Eye Tracking to Elucidate the Mechanisms Underlying Stimulation-Enhanced Visual Target Detection

Transcranial direct current stimulation (tDCS) is a noninvasive form of brain stimulation that involves passing a weak electrical current between electrodes on the scalp to modulate underlying neural tissue. TDCS has been shown to modulate cognition in a variety of domains, including memory, attention, and visual processing. Prior work from our laboratory has shown positive effects of tDCS on learning to detect target objects hidden in complex naturalistic visual scenes and learn rules for categorizing images, though the mechanism for these benefits remains unknown. One possibility is that tDCS optimizes visual search by modulating visual attention or via the reduction in search errors. One method of quantifying visual attention is to use eye tracking to record search patterns to determine if and how visual search is adjusted under verum stimulation conditions. Eye tracking data allows classification of errors into error types, including sampling errors (failing to look in the relevant region), recognition errors (looking at the critical portion of a scene, but failing to recognize it as such as evidenced by visual fixation), and decision-making errors (fixating on the relevant portion of a scene, but making the wrong determination). Our results indicate that the benefit tDCS confers on visual search for targets stems from the reduction in decision-making errors when targets are present (Cohen’s d = 0.86). Also reported is a replication of previous findings showing a tDCS-dependent improvement in learning this task, learning score (Cohen’s d = 0.88); d’ (Cohen’s d = 1.00). This provides support for moving tDCS into the application space by pairing it with analysts who are concerned with the type of search error that is corrected via stimulation.

attention↗

Molecular homing and retention of muscle membrane stabilizing copolymers by non-invasive optical imaging in vivo

First-in-class membrane stabilizer Poloxamer 188 (P188) has been shown to confer membrane protection in an extensive range of clinical conditions; however, elements of the systemic distribution and localization of P188 at the organ, tissue, and muscle fiber levels in vivo have not yet been elucidated. Here we used non-invasive fluorescence imaging to directly visualize and track the distribution and localization of P188 in vivo. The results demonstrated that the Alx647 probe did not alter the fundamental properties of P188 to protect biological membranes. Distribution kinetics in mdx mice demonstrated that Alx647 did not interface with muscle membranes and had fast clearance kinetics. In contrast, the distribution kinetics for P188-Alx647 was significantly slower, indicating a dramatic depot and retention effect of P188. Results further demonstrated the significant retention of P188-Alx647 in the skeletal muscle of mdx mice, showing a significant genotype effect with a higher fluorescence signal in the mdx muscles over BL10 mice. High-resolution optical imaging provided direct evidence of P188 surrounding the sarcolemma of skeletal and cardiac muscle cells. Taken together, these findings provide direct evidence of muscle-disease-dependent molecular homing and retention of synthetic copolymers in striated muscles thereby facilitating advanced studies of copolymer-membrane association in health and disease.

60 APPLIED LIFE SCIENCES↗

Anomalous nanoparticle surface diffusion in LCTEM is revealed by deep learning-assisted analysis

Significance Liquid cell transmission electron microscopy (LCTEM) is an emerging technique, which enables nanoscale visualization and tracking of single nanoparticles near interfaces with unprecedented spatial resolution. Here, we studied the diffusion of nanoparticles in LCTEM experiments using techniques powered by deep neural networks and statistical tests. We observed two underlying regimes of diffusive behavior which are governed by the interaction of the electron beam, the nanoparticle, the nearby substrate, and the liquid environment. This understanding forms the foundation to use LCTEM for single-nanoparticle tracking for a broad range of nanoparticles, interfaces, and liquids.

Jamali, Vida↗

Tracking propagation of ultrashort intense laser pulses in gases via probing of ionization

We use optical interferometry to study the propagation of femtosecond laser pulses in gases. We show the measurements of propagation in a nitrogen gas jet and we compare the results with propagation in He under the same irradiation conditions. We find that in the case of nitrogen, the detailed temporal structure of the laser pulse can be tracked and visualized by measuring the phase and the resulting electron-density map. A dramatically different behavior occurs in He gas jets, where no details of the temporal structure of the laser pulse are visible. These observations are explained in terms of the ionization dynamics of nitrogen compared to helium. These circumstances make N{sub 2} gas sensitive to variations in the electric field and, therefore, allow the laser-pulse temporal and spatial structures to be visualized in detail.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Eagle Take Minimization System

Laufer Wind (LW) has developed a prototype Eagle Take Minimization System that shows capabilities for autonomously detecting, tracking, and visually identifying eagles and other protected avians out to approximately 1 km range with no human-in-the-loop. This type of detection system is important for animals that fly too close to facilities that can harm them, such as large wind turbine farms. The Eagle Take Minimization System consists of networked and sensor-fused commercial-off-the-shelf (COTS) X-band radars, PZT visible cameras and a Central Controller computer that can be interfaced with a wind facility SCADA. The intended design of the Eagle Take System is to detect and reliably identify eagles at far enough range so that proximate turbines can be stopped to greatly reduce the risk of eagle injury or death. These curtailed turbines would be released when eagles have moved away. Other wind turbines that are not in close proximity to eagles would continue producing electricity as usual throughout the process.

17 WIND ENERGY↗

Metaoptics Enabled Multifunctional Imaging

Despite the fact that most microorganisms occupy two- and three-dimensional space in heterogeneous arrangements and in proximity to other microorganisms of different species, much of our current knowledge about their metabolic processes is derived from homogenizing, then analyzing, the chemical content of cultures containing a single microbial species. This project addressed this fundamental dichotomy by developing a set of optical imaging principles combining multiple new technologies. The imaging strategies developed in this project combine metaoptics structures with active in situ nanoscale control of the chemical environment and applied them to a microbial system, Myxococcus xanthus, with particular relevance to the DoE mission. The combination of metaoptical architectures and nanoscale control over the molecular environment enables: (a) precise control over the electromagnetic (EM) field at length scales smaller than the wavelength of light; (b) control of the interaction of the EM field with critical molecular systems in DOE relevant microbes; (c) control over the chemical environment – especially the presence and quantity of reactive oxygen species (ROS) that can affect redox homeostasis; and (d) the ability to ask new kinds of questions not accessible to ‘omics’ approaches or standard methods of biological imaging. These capabilities are applicable to detailed studies of metabolic pathways in microbes and to lignocellulosic biomass deconstruction. To accomplish these objectives, we pursued two over-arching technical goals: (1) the development of new metaoptics-enabled approaches to imaging and spectroscopic characterization; and (2) the development of tools to control the chemical environment of a microbial sample with nanometer-scale precision. Goal 1 was addressed through the design, fabrication, and characterization of new metasurfaces capable of super-resolution imaging through extreme confinement of the optical field. Goal 2 was addressed by controlling the redox potential on the nanoscale in microbial communities and characterizing their effect on intrinsic bacterial fluorophores which act as molecular sentinels and through characterization of soluble factors secreted by Myxococcus xanthus by confocal Raman imaging. The optical imaging/sensing approaches developed here make it possible to use these powerful new imaging and sensing modalities in metabolic studies by making it possible to visualize and track the spatial and temporal expression patterns of natural or engineered pathways in microorganisms.

09 BIOMASS FUELS↗

The 13 November 1984 occultation of BD +08 deg 0471 by (1) Ceres

The 13 November 1984 occultation of BD +08 deg 0471 was discovered during a photographic search carried out with the 0.5 meter Carnegie Double Astrograph at Lick Observatory and the Lowell Observatory PDS microdensitometer. Such a search was stimulated by the curious fact that few favorably located occultations of AGK3 or SAO catalog starts by Ceres will occur during the 1980s. The occultation on 13 November, however, is a particularly good event. The star is 1000 cubic M in V, yielding a predicted drop at occultation of about 10%. Such a drop can be detected by small telescopes equipped with photoelectric photometers, but is too small to be seen visually. The track was predicted to cross the Caribbean, Florida, southern Texas, and Mexico. Based on this prediction, preparations were made to observe the event in Mexico using four portable occultation data systems.

Wasserman, L. H.↗

The 13 November 1984 occultation of BD +08 deg 0471 by (1) Ceres

The November 13, 1984 occultation of BD +08 deg 0471 was discovered during a photographic search carried out with the 0.5 meter Carnegie Double Astrograph at Lick Observatory and the Lowell Observatory PDS microdensitometer. Such a search was stimulated by the curious fact that few favorably located occultations of AGK3 or SAO catalog starts by Ceres will occur during the 1980s. The occultation on November 13, however, is a particularly good event. The star is 1000 cubic M in V, yielding a predicted drop at occultation of about 10 percent. Such a drop can be detected by small telescopes equipped with photoelectric photometers, but is too small to be seen visually. The track was predicted to cross the Caribbean, Florida, southern Texas, and Mexico. Based on this prediction, preparations were made to observe the event in Mexico using four portable occultation data systems.

Wasserman, L. H.↗

Vaporizing particle velocimeter

A velocimeter measures flow characteristics of a flow traveling through a chamber in a given direction. Tracer particles are entrained in the flow and a source of radiant energy produces an output stream directed transversely to the chamber, having a sufficient intensity to vaporize the particles as they pass through the output stream. Each of the vaporized particles explodes to produce a shock wave and a hot core, and a flow visualization system tracks the motion of the hot cores and shock waves to measure the velocity of each tracer particle and the temperature of the flow around the tracer.

Weinstein, Leonard M.↗

Precise Image-Based Motion Estimation for Autonomous Small Body Exploration

We have developed and tested a software algorithm that enables onboard autonomous motion estimation near small bodies using descent camera imagery and laser altimetry. Through simulation and testing, we have shown that visual feature tracking can decrease uncertainty in spacecraft motion to a level that makes landing on small, irregularly shaped, bodies feasible. Possible future work will include qualification of the algorithm as a flight experiment for the Deep Space 4/Champollion comet lander mission currently under study at the Jet Propulsion Laboratory.

Johnson, Andrew Edie↗

Heart Research

James Antaki and a group of researchers from the University of Pittsburgh School of Medicine used many elements of the Technology Utilization Program while looking for a way to visualize and track material points within the heart muscle. What they needed were tiny artificial "eggs" containing copper sulfate solution, small enough (about 2 mm in diameter) that they would not injure the heart, and large enough to be seen in Magnetic Resonance Imaging (MRI) images; they also had to be biocompatible and tough enough to withstand the beating of the muscle. The group could not make nor buy sufficient containers. After reading an article on microspheres in NASA Tech Briefs, and a complete set of reports on microencapsulation from the Jet Propulsion Laboratory (JPL), JPL put Antaki in touch with Dr.Taylor Wang of Vanderbilt University who helped construct the myocardial markers. The research is expected to lead to improved understanding of how the heart works and what takes place when it fails.

Source record↗

Machine Vision for Autonomous Small Body Navigation

This paper describes machine vision algorithms that enable precision guidance and hazard avoidance during small body exploration through onboard visual feature tracking and landmark recognition.

Estimation Landmark Recognition↗

Autonomous Vision-Based Manipulation from a Rover Platform

Current rover designs use on-board manipulators to enhance their capabilities for planetary exploration and in-situ science. In this paper, we describe how these manipulators can be used to perform two types of operations: rock sample aquisition for return to earth and instrument placement for in-situ science meausrements.

autonomous manipulation rock acquisition instrumen↗