Search NASA⌕ Search

SEARCH · Search NASA

Results for “x-ray ct”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Advanced Instrumentation for Metal Additive Manufacturing

Laser powder bed fusion (LPBF) is the most widely used process for metal additive manufacturing (AM), particularly where complex geometries provide performance advantages unattainable with traditional manufacturing techniques. However, LPBF is highly sensitive to innate variability in both the powder spreading and fusion steps, often leading to defects such as pores that are difficult to detect yet significantly impair component mechanical properties and fatigue life. This thesis presents a range of novel instruments enabling both precise assessment of powder layer characteristics and in-situ thermal metrology of metal AM to advance the quality control of LPBF. First, leveraging a custom X-ray microscope and a radiation-transport model developed through this work, transmission X-ray imaging is used to study spreading of thin metal powder layers. Effective layer depth is directly mapped at a process-relevant size scale, surpassing optical techniques that can only estimate local deposition from layer surface topography. Layer packing density and quality are shown to be influenced by powder flowability and particle size relative to nominal powder layer thickness. Layer quality is additionally connected to the geometry of the spreading implement and its velocity. This technique and its presented findings enable pairing feedstocks with spreading strategies that create layers with consistent packing density and uniformity. Second, a twofold approach is employed to optically interrogate the laser fusion step of LPBF for observing signatures of defect formation. Aperture division multiplexing is conceptualized, providing for simultaneous laser delivery and high-fidelity infrared (IR) process monitoring through a common optic. In-situ microscopy at 50 μm spatial resolution and at mid-wave IR wavelengths is proven readily achievable with the first purpose-built optic of this type. Next, a bespoke imaging spectrometer, along with a temperature-emissivity separation technique, is used to retrieve accurate process temperatures over a 1000 K range. Data from these instruments are correlated to porosity as fine as 4.3 μm in two LPBF test artifacts, as verified using computed tomography (CT), establishing the viability of robust optically-based component qualification.

Penny, Ryan↗

Determining anisotropic slip system rate sensitivities of Ti-6Al-4V using high-energy X-ray diffraction microscopy

Variation of strain rate sensitivity among different families of slip systems in the hexagonal close-packed (α) phase of titanium (Ti) alloys has the potential to alter microscale load redistribution during both creep and dwell fatigue loading. However, existing literature contains conflicting reports regarding the degree of anisotropy present in the strain rate sensitives between α slip system families across Ti alloys. Here, we quantify the strain rate sensitivity of α slip system families in Ti-6Al-4V using high-energy X-ray diffraction microscopy (HEDM). We present a novel procedure in which we utilize the HEDM-measured grain-scale stress states during stress relaxation to determine the strain rate sensitivities of the basal $\langle a \rangle$ , prismatic $\langle a \rangle$, and first-order pyramidal $\langle c + a \rangle$ slip system families. In addition, we measure the strain rate sensitivity exponent of the macroscopic response and the α phase for comparison. We find rate sensitivities for the different slip system families to range from 0.02 to 0.04, which—while varied—are relatively isotropic in comparison with some values presented in the literature. We also demonstrate the effects of the measured anisotropic rate sensitivities using crystal plasticity finite element simulations.

Peterson, Kenneth M. [Pennsylvania State Univ., Un↗

Degradation of Fuel Cell Membrane Electrode Assemblies from Buses Operated More than 25,000 h

This study investigates the performance losses and degradation of proton-exchange-membrane fuel-cell stacks taken from the Alameda Contra Costa Transit District (AC Transit) bus system (Alameda and Contra Costa counties, California, United States) that were operated for over 25,000 h. Here, we focus on the origin of differences in electrochemical performance between beginning-of-life (BOL) and end-of-life states as well as diagnostic data acquired during the lifetime of the buses. In doing so, we employ in- and ex- situ characterization methods such as polarization curves, electrochemical impedance spectroscopy, electron microscopy, and X-ray characterization. Uniform degradation of the catalyst layer including Pt agglomeration/migration and electrode thinning was observed in all of the post-teardown measurements compared to BOL materials resulting from years of field operation. Despite these changes, the measured post-teardown performance suggests a sufficient output for the expected load, which indicate factors other than degradation of the membrane-electrode assemblies (MEAs) are likely responsible for the decommissioning of the stacks. The findings indicate that these MEA materials can enable long lifetime in fuel-cell vehicles, if the MEAs are not subjected to adverse operating conditions. The results also highlight the need for more in-vehicle diagnostics to maximize the lifetime of fuel cell vehicle (FCV) powerplants.

25 ENERGY STORAGE↗

Pre- and post-launch operation of the Resolve soft X-ray spectrometer onboard the XRISM satellite

Resolve is a high-resolution X-ray spectrometer onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), launched on September 6 (UT), 2023. The Resolve has performed better than its required spectral resolution (7 eV at full width at half maximum at 6 keV), both on the ground and in orbit, and has been confirmed to have comparable performance to the soft X-ray spectrometer onboard the ASTRO-H (Hitomi) satellite. The focal plane is composed of an array of microcalorimeter detectors operated at 50 mK to achieve the required energy resolution, and the cooling system is designed to satisfy the lifetime requirement of over 3 years. The focal plane and cooling system are contained in a vacuum-insulated dewar. The cooling system is equipped with a two-stage adiabatic demagnetization refrigerator (ADR) that uses superfluid liquid helium (LHe) as its heat sink. The system includes a third ADR stage that can be used to provide the heat sink when the helium is exhausted. A Joule–Thomson cooler and several two-stage Stirling coolers are used to reduce the heat load on the LHe. During pre-launch operations, we carried out a superfluid LHe top-off operation. The resultant amount of LHe onboard Resolve was over 35 L before launch, which is sufficient to meet the lifetime requirement. During post-launch operation, the LHe vent valve was opened 5 min after launch during rocket acceleration, and the cryocoolers were turned on after several orbits, as planned, which established stable cooling within the dewar. Pre- and post-launch operations for the Resolve instrument were planned around multiple constraints from launch vehicle operations; all were successfully completed, and the launch requirements were fully met.

X-Ray Imaging and Spectroscopy Mission↗

Segmentation of RDX and TNT in X‐Ray Computed Tomography Reconstructions of Melt‐Cast Explosives

ABSTRACT Three‐dimensional mesoscale characterization of heterogeneous melt‐cast high explosives is challenging because of the difficulty differentiating binder from explosive crystals: two functionally different materials which are typically similar in density by design. Here, we report an algorithm which can differentiate hexahydro‐1,3,5‐trinitro‐1,3,5‐triazine (RDX) from 2,4,6‐trinitrotoluene (TNT) in x‐ray computed tomography (CT) volumes with tens of microns resolution. This method allows us to quantify RDX/TNT content, porosity, and RDX domain size. We calibrated the segmentation algorithm using simulated x‐ray CT volumes containing object models of RDX crystals within a TNT matrix. We then segmented and analyzed CT data for Composition B (Comp B), a 60/40 RDX/TNT mixture, and Cyclotol, a 75/25 RDX/TNT mixture. We examined melt‐cast samples fabricated with 100% theoretical maximum density (TMD) and 85% TMD. For the 100% TMD Comp B and Cyclotol samples, the RDX content values calculated by segmentation were 3% and 9% lower, respectively, than the values measured by high‐performance liquid chromatography on material from the same synthesis lots. This result is consistent with the expected underreporting of RDX content resulting from x‐ray CT resolution limits on RDX particles with diameters smaller than 25 µm. The 85% TMD samples were less accurately segmented with our algorithm due to the confounding presence of voids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A new frame-based registration algorithm

This paper presents a new algorithm for frame registration. Our algorithm requires only that the frame be comprised of straight rods, as opposed to the N structures or an accurate frame model required by existing algorithms. The algorithm utilizes the full 3D information in the frame as well as a least squares weighting scheme to achieve highly accurate registration. We use simulated CT data to assess the accuracy of our algorithm. We compare the performance of the proposed algorithm to two commonly used algorithms. Simulation results show that the proposed algorithm is comparable to the best existing techniques with knowledge of the exact mathematical frame model. For CT data corrupted with an unknown in-plane rotation or translation, the proposed technique is also comparable to the best existing techniques. However, in situations where there is a discrepancy of more than 2 mm (0.7% of the frame dimension) between the frame and the mathematical model, the proposed technique is significantly better (p < or = 0.05) than the existing techniques. The proposed algorithm can be applied to any existing frame without modification. It provides better registration accuracy and is robust against model mis-match. It allows greater flexibility on the frame structure. Lastly, it reduces the frame construction cost as adherence to a concise model is not required.

NASA Center ARC↗

Weak phonon coupling to nematic quantum critical mode in BaFe 2 ⁢(As 1−𝑥 ⁢P 𝑥 ) 2

Here, in this work, we investigate the softening of the in-plane transverse acoustic phonon driven by electronic nematicity in BaFe 2 ⁢(As 1−𝑥 ⁢P 𝑥 ) 2 using inelastic x-ray scattering, with a focus on the optimally doped sample (𝑥 = 0.31) sample—a system exhibiting signatures of a putative nematic quantum critical point and minimal disorder among iron pnictides. We observe only a modest softening of the phonon frequency and no evidence of critical damping, suggesting that the nematic quantum critical fluctuations couple only weakly to the lattice from our quantum critical model. Given the close proximity of the structural and magnetic transition temperatures in the underdoped sample—which implies that spin-nematic fluctuations couple strongly to the lattice—we conjecture that the quantum critical nematic fluctuations are predominantly orbital in origin.

Wu, S. [University of California, Berkeley, CA (Un↗

Synthesis, Properties, and Electrochemical Proton Reduction of a Homoleptic Tetrathiolato Ni-Site Model of [NiFe]-Hydrogenase

[NiFe]-hydrogenase enzymes process H 2 at a nonplanar tetracysteinato-Ni site, the sole participator in proton binding/redox chemistry during turnover. With the objective of assessing whether a simple tetrahedral/ tetrathiolato-Ni 2+ core could promote H 2 evolution reaction (HER), we synthesized (Et 4 N) 2 [Ni(S-p-CF 3 −Ph) 4 ] (1) employing para-trifluoromethylbenzenethiolate ( − S-p-CF 3 −Ph) as a Ni-site analog of [NiFe]-hydrogenase. Spectroscopic measurements and X-ray crystallography confirm the distorted tetrahedral geometry of 1. Dissolution of 1 results in partial thiolate dissociation and formation of S,S-bridged complexes such as (Et 4 N) 2 [Ni 2 (S-p-CF 3 −Ph) 6 ] (3) among other ill-defined species. Dissociation is further accelerated in the presence of Brønsted acids, complicating the assessment of 1 for proton reduction. However, this dissociation/proton instability is suppressed in the presence of additional thiolate ligand to ensure tetrahedral/tetrathiolato 1 persists in solution. Electrochemical HER activity was evaluated by monitoring the current response of an MeCN solution of 1/ excess thiolate after sequential titration with a weak Brønsted acid (acetic acid). The results suggest that 1 is a modest electrocatalyst for the HER with a turnover frequency of 14.5 ± 3.6 s −1 and an overpotential of 0.72 ± 0.02 V. Control experiments and supplementary DFT computations indicate that 1, or a species derived from 1, is responsible for the HER and suggest an ECCE-type mechanism.

Evolution reactions↗

Goal-directed ultrasound in the detection of long-bone fractures

BACKGROUND: New portable ultrasound (US) systems are capable of detecting fractures in the remote setting. However, the accuracy of ultrasound by physicians with minimal ultrasound training is unknown. METHODS: After one hour of standardized training, physicians with minimal US experience clinically evaluated patients presenting with pain and trauma to the upper arm or leg. The investigators then performed a long-bone US evaluation, recording their impression of fracture presence or absence. Results of the examination were compared with routine plain or computer aided radiography (CT). RESULTS: 58 patients were examined. The sensitivity and specificity of US were 92.9% and 83.3%, and of the physical examination were 78.6% and 90.0%, respectively. US provided improved sensitivity with less specificity compared with physical examination in the detection of fractures in long bones. CONCLUSION: Ultrasound scans by minimally trained clinicians may be used to rule out a long-bone fracture in patients with a medium to low probability of fracture.

Validation Studies↗

New approaches to virtual environment surgery

This research focused on two main problems: 1) low cost, high fidelity stereoscopic imaging of complex tissues and organs; and 2) virtual cutting of tissue. A further objective was to develop these images and virtual tissue cutting methods for use in a telemedicine project that would connect remote sites using the Next Generation Internet. For goal one we used a CT scan of a human heart, a desktop PC with an OpenGL graphics accelerator card, and LCD stereoscopic glasses. Use of multiresolution meshes ranging from approximately 1,000,000 to 20,000 polygons speeded interactive rendering rates enormously while retaining general topography of the dataset. For goal two, we used a CT scan of an infant skull with premature closure of the right coronal suture, a Silicon Graphics Onyx workstation, a Fakespace Immersive WorkBench and CrystalEyes LCD glasses. The high fidelity mesh of the skull was reduced from one million to 50,000 polygons. The cut path was automatically calculated as the shortest distance along the mesh between a small number of hand selected vertices. The region outlined by the cut path was then separated from the skull and translated/rotated to assume a new position. The results indicate that widespread high fidelity imaging in virtual environment is possible using ordinary PC capabilities if appropriate mesh reduction methods are employed. The software cutting tool is applicable to heart and other organs for surgery planning, for training surgeons in a virtual environment, and for telemedicine purposes.

NASA Discipline Neuroscience↗

Hubble Space Telescope Observations within the Sphere of Influence of the Powerful Supermassive Black Hole in PKS 0745-191

We present Space Telescope Imaging Spectrograph observations from the Hubble Space Telescope of the supermassive black hole (SMBH) at the center of PKS 0745-191, a brightest cluster galaxy (BCG) undergoing powerful radio-mode active galactic nucleus (AGN) feedback (P cav ~ 5 × 10 45 erg s -1 ). These high-resolution data offer the first spatially resolved map of gas dynamics within an SMBH's sphere of influence under such powerful feedback. Our results reveal the presence of highly chaotic, nondrotational ionized gas flows on subkiloparsec scales, in contrast to the more coherent flows observed on larger scales. While radio-mode feedback effectively thermalizes hot gas in galaxy clusters on kiloparsec scales, within the core, the hot gas flow may decouple, leading to a reduction in angular momentum and supplying ionized gas through cooling, which could enhance accretion onto the SMBH. This process could, in turn, lead to a self-regulating feedback loop. Compared to other BCGs with weaker radio-mode feedback, where rotation is more stable, intense feedback may lead to more chaotic flows, indicating a stronger coupling between jet activity and gas dynamics. Additionally, we observe a sharp increase in velocity dispersion near the nucleus, consistent with a very massive M BH ~ 1.5 × 10 10 M ⊙ SMBH. The density profile of the ionized gas is also notably flat, paralleling the profiles observed in X-ray gas around galaxies where the Bondi radius is resolved. These results provide valuable insights into the complex mechanisms driving galaxy evolution, highlighting the intricate relationship between SMBH fueling and AGN feedback within the host galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

Mechanism of Tyrosine-Driven Deprotonation in Photosystem II Revealed by Multiscale Simulations

Photosystem II (PSII) drives light-induced water oxidation via stepwise redox transitions of its oxygen-evolving complex (OEC), a Mn 4 Ca cluster advancing through five intermediate S-states (S 0 –S 4 ). The S 2 → S 3 transition involves a redox event in which a Mn ion donates an electron to the redox-active tyrosine YZ, coupled to deprotonation of an OEC-bound water ligand─yet the underlying coupling mechanism remains unresolved. Time-resolved serial femtosecond crystallography (TR-SFX) has revealed transient electron density shifts near the redox-active tyrosine Y Z , interpreted as sequential oxidation and reduction, with reduction initiating ∼1 μs after excitation and substantially progressed by 30 μs. However, this interpretation conflicts with kinetics from photothermal beam deflection (PBD), time-resolved X-ray absorption spectroscopy (TR-XAS), and electron paramagnetic resonance (EPR), which place electron transfer at 190–400 μs and proton transfer around 30 μs. Here, we reconcile these discrepancies using quantum mechanics/molecular mechanics (QM/MM) and molecular dynamics (MD) simulations. We show that oxidation of P680 and Y Z breaks the symmetry of the nearby hydrogen bonds involving water molecule W4, displacing Y Z and replicating the TR-SFX features of Y Z and Q165 observed at 1 μs. This local perturbation propagates through a hydrogen-bond network, transmitting the electrostatic signal from Y Z to the E65-E312 dyad and triggering redox-coupled deprotonation via the Cl1 channel. By 30 μs, the hydrogen-bond symmetry is restored through deprotonation of W2 (or alternatively W1), reproducing the disappearance of TR-SFX density differences around Y Z and Q165 without requiring Y Z reduction. Our proposed mechanism also gives molecular insights into the O6* density, assigning it to water reorganization rather than a discrete Ca-bound hydroxide species. Here, our results reveal a detailed atomistic mechanism linking Y Z oxidation to long-range proton release and suggest a functional role for the nearby Cl – ion in proton transfer. More broadly, this study underscores the importance of hydrogen-bond dynamics in mediating redox-driven proton transport and demonstrates how integrative simulations can resolve mechanistic ambiguities.

Deprotonation↗

Cysteine Rich Intestinal Protein 2 is a copper-responsive regulator of skeletal muscle differentiation and metal homeostasis

Copper (Cu) is essential for respiration, neurotransmitter synthesis, oxidative stress response, and transcription regulation, with imbalances leading to neurological, cognitive, and muscular disorders. Here we show the role of a novel Cu-binding protein (Cu-BP) in mammalian transcriptional regulation, specifically on skeletal muscle differentiation using murine primary myoblasts. Utilizing synchrotron X-ray fluorescence-mass spectrometry, we identified murine cysteine-rich intestinal protein 2 (mCrip2) as a key Cu-BP abundant in both nuclear and cytosolic fractions. mCrip2 binds two to four Cu + ions with high affinity and presents limited redox potential. CRISPR/Cas9-mediated deletion of mCrip2 impaired myogenesis, likely due to Cu accumulation in cells. CUT&RUN and transcriptome analyses revealed its association with gene promoters, including MyoD1 and metallothioneins, suggesting a novel Cu-responsive regulatory role for mCrip2. Our work describes the significance of mCrip2 in skeletal muscle differentiation and metal homeostasis, expanding understanding of the Cu-network in myoblasts. Copper (Cu) is essential for various cellular processes, including respiration and stress response, but imbalances can cause serious health issues. This study reveals a new Cu-binding protein (Cu-BP) involved in muscle development in primary myoblasts. Using unbiased metalloproteomic techniques and high throughput sequencing, we identified mCrip2 as a key Cu-BP found in cell nuclei and cytoplasm. mCrip2 binds up to four Cu + ions and has a limited redox potential. Deleting mCrip2 using CRISPR/Cas9 disrupted muscle formation due to Cu accumulation. Further analyses showed that mCrip2 regulates the expression of genes like MyoD1, essential for muscle differentiation, and metallothioneins in response to copper supplementation. This research highlights the importance of mCrip2 in muscle development and metal homeostasis, providing new insights into the Cu-network in cells.

59 BASIC BIOLOGICAL SCIENCES↗

Pt Nanoparticle Disintegration at Oxide Interfaces Enhances CO Oxidation Catalysis

Understanding how supported metal nanoparticles dynamically evolve under reaction conditions is critical for controlling their catalytic function. Here, the mechanism behind the dynamic disintegration of Pt nanoparticles (NPs) supported on CeOx-TiO2 (CT) during CO oxidation is elucidated, leading to the formation of single atoms (SAs) and/or sub-nanometer clusters. Density functional theory (DFT) calculations reveal that strong Pt-CO interactions weaken Pt─Pt cohesion, while electronic coupling between Pt and Ce ions stabilizes Pt-CO* intermediates at the oxide interface. Surface oxygen vacancies kinetically trap Pt-CO*, but the vacancies are replenished under oxygen-rich conditions, enabling Pt-CO* surface diffusion and subsequent structural reorganization. In situ spectroscopic analyses confirm the oxygen-driven transformation of Pt NPs, correlating with a threefold increase in mass-specific activity at 150 °C. These findings demonstrate that interfacial oxygen dynamics and metal-support interactions can be leveraged to induce nanoparticle disintegration and optimize catalytic performance, highlighting the catalytic potential of interface-engineered Pt nanostructures.

CO oxidation↗

State-of-Charge Investigation of Lithium Manganese Dioxide Primary Batteries Utilizing X-ray Computed Tomography

Lithium primary batteries (LPBs) represent a class of energy storage devices, uniquely suited for mission-critical applications including emergency backup power, aerospace and defense electronics, implantable medical devices, and remote sensing. Despite their technological maturity and distinct advantages over rechargeable lithium-ion batteries (i.e., superior shelf life and operational simplicity), state-of-charge (SoC) estimation in these batteries remains a persistent challenge due to the lack of a reliable, quantifiable diagnostic technique. In this work, we investigate X-ray computed tomography (X-CT) as a transformative and accurate SoC estimation technique for LPBs. Results gained through X-CT measurements reveal systematic, quantifiable structural changes in cathode morphology and geometry during discharge, establishing a direct structural basis for SoC estimation, with a maximum relative standard deviation of 2.3%. This work establishes a pathway toward operando, imaging-driven SoC diagnostics that can significantly enhance the reliability of SoC estimation in LPBs.

25 ENERGY STORAGE↗

Development of fiber orientation in injection molding: Comparison of glass fiber, carbon fiber and their hybrid composites

Fiber orientation distribution (FOD) in injection-molded panels with respect to distance from the gate was analyzed using X-ray computed tomography (X-CT) for glass fiber (GF), carbon fiber (CF), and hybrid CF/GF (CGF) reinforced nylon 66. To understand the reason behind the FOD with different fiber types, computational fluid dynamics (CFD) and rheology were performed. Samples were extracted at three locations: near the gate, center, and opposite end. Thickness of the layers of typical skin-shell-core type FOD varied with fiber type and location. GF achieved flow direction alignment (in shell) earlier than viscous CF and CGF near the gate, whereas CF showed the highest flow-direction alignment at the center due to shear induced orientation. At the opposite end, GF experienced more backflow than others indicating faster mold filling owing to its lower viscosity. Hybrid CGF exhibited GF-dominated center and CF-dominated end region. The numerical model used to obtain FOD and rheological predictions for the CF and GF composites served to corroborate the trends observed in the experimental trials. The FOD responses across fiber types and location were reflected in their longitudinal and transverse properties. Only GF showed higher longitudinal modulus over transverse modulus near the gate attributed to rapid alignment, whereas CF and CGF exhibited opposite trend. However, fountain flow enhanced the longitudinal modulus over transverse modulus with the distance for all, particularly for CF. This study offers insights into mold filling behavior of different fibers which are critical in optimizing injection molding conditions for tailored final properties.

36 MATERIALS SCIENCE↗

Design and Production for Maximum Structural Efficiency With Respect to Fiber Orientation With Increased Understanding of Hybrid Fiber Flow Behavior

Discontinuous fiber-reinforced thermoplastic composites have gained considerable attention in automotive, aerospace, and other industries, due to their high-rate of production combined with their ability to attain complex and intricate shapes. Among other high-rate thermoplastic manufacturing processes, injection-molding is one of the most common manufacturing methods due to fast production and high surface finishing of complex geometries. Fiber orientation in discontinuous fiber composites plays a pivotal role in determining the mechanical, electrical, and thermomechanical properties, underscoring the necessity to comprehend fiber orientation in injection molded parts. Among different fiber types, glass and carbon fibers are most common in the composite industries. The recent trend of hybrid composites comprising both glass fiber (GF) and carbon fiber (CF) is also gaining importance in the automotive industry. Hybrid fiber options allow designers to optimize the balance between glass and carbon fibers by leveraging the high durability and low cost of GF while the strength and lightweight properties of CF. Consequently, comparing the fiber oriented distribution (FOD) of injection molded composites containing GF, CF, and a hybrid of GF/CF is critical to investigating the local mechanical properties of intricate structures for high-end applications. In Phase I of this project, FOD in injection-molded panels with respect to distance from the gate was analyzed using X-ray computed tomography (X-CT) for GF, CF, and hybrid CF/GF (CGF) reinforced nylon 66. To understand the reason behind the FOD with different fiber types, computational fluid dynamics (CFD) and rheology were performed. Samples were extracted at three locations: near the gate, center, and opposite end. Thickness of the layers of typical skin-shell-core type FOD varies with fiber type and location. GF achieved flow direction alignment (in shell) earlier than viscous CF and CGF near the gate, whereas CF showed the highest flow-direction alignment at the center due to shear induced orientation. At the opposite end, GF experienced more backflow than others indicating faster mold filling owing to its lower viscosity. Hybrid CGF exhibited GF-dominated center and CF-dominated end region. The numerical model used to obtain FOD and rheological predictions for the CF and GF composites served to corroborate the trends observed in the experimental trials. The FOD responses across fiber types and location were reflected in their longitudinal and transverse properties. Only GF showed higher longitudinal modulus over transverse modulus near the gate attributed to rapid alignment, whereas CF and CGF exhibited opposite trend. However, fountain flow enhanced the longitudinal modulus over transverse modulus with the distance for all, particularly for CF. This study offers insights into mold filling behavior of different fibers which are critical in optimizing injection molding conditions for tailored final properties.

36 MATERIALS SCIENCE↗

Cross-calibration of liquid and solid QCT calibration standards: corrections to the UCSF normative data

Quantitative computed tomography (QCT) has been shown to be a precise and sensitive method for evaluating spinal bone mineral density (BMD) and skeletal response to aging and therapy. Precise and accurate determination of BMD using QCT requires a calibration standard to compensate for and reduce the effects of beam-hardening artifacts and scanner drift. The first standards were based on dipotassium hydrogen phosphate (K2HPO4) solutions. Recently, several manufacturers have developed stable solid calibration standards based on calcium hydroxyapatite (CHA) in water-equivalent plastic. Due to differences in attenuating properties of the liquid and solid standards, the calibrated BMD values obtained with each system do not agree. In order to compare and interpret the results obtained on both systems, cross-calibration measurements were performed in phantoms and patients using the University of California San Francisco (UCSF) liquid standard and the Image Analysis (IA) solid standard on the UCSF GE 9800 CT scanner. From the phantom measurements, a highly linear relationship was found between the liquid- and solid-calibrated BMD values. No influence on the cross-calibration due to simulated variations in body size or vertebral fat content was seen, though a significant difference in the cross-calibration was observed between scans acquired at 80 and 140 kVp. From the patient measurements, a linear relationship between the liquid (UCSF) and solid (IA) calibrated values was derived for GE 9800 CT scanners at 80 kVp (IA = [1.15 x UCSF] - 7.32).(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Program Space Physiology and Countermeasures↗