Search NASA⌕ Search

SEARCH · Search NASA

Results for “IRRADIATION DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

RIR-MAPLE deposition of conjugated polymers and hybrid nanocomposites for application to optoelectronic devices

Resonant infrared matrix-assisted pulsed laser evaporation (RIR-MAPLE) is a variation of pulsed laser deposition that is useful for organic-based thin films because it reduces material degradation by selective absorption of infrared radiation in the host matrix. A unique emulsion-based RIR-MAPLE approach has been developed that reduces substrate exposure to solvents and provides controlled and repeatable organic thin film deposition. In order to establish emulsion-based RIR-MAPLE as a preferred deposition technique for conjugated polymer or hybrid nanocomposite optoelectronic devices, studies have been conducted to demonstrate the value added by the approach in comparison to traditional solution-based deposition techniques, and this work will be reviewed. The control of hybrid nanocomposite thin film deposition, and the photoconductivity in such materials deposited using emulsion-based RIR-MAPLE, will also be reviewed. The overall result of these studies is the demonstration of emulsion-based RIR-MAPLE as a viable option for the fabrication of conjugated polymer and hybrid nanocomposite optoelectronic devices that could yield improved device performance.

36 MATERIALS SCIENCE↗

Development of Technology for Detachment of Calandria Tube Rolled Joint of Pressurised Heavy Water Reactors

Coolant channel assembly of PHWRs consisting mainly of pressure tube and calandria tube undergoes sag due to irradiation enhanced creep during its life time. Typical service life of the pressure tube is limited to about 15 full power years due to such ageing related degradation. On account of the degradation the pressure tube needs replacement more than twice during the licensed period of reactor operation. As the sag in the calandria tube is also excessive, it has to be replaced to facilitate installation of new and straight pressure tube during retubing and to avoid interference of sagged calandria tube with horizontal reactivity devices. The calandria tube and the tube sheet are joined by sandwich type rolled joints. For detaching the joint an improved technique has been developed that helps to detach the joint without affecting the groove geometry and integrity of the tube sheet. The system works on the principle of fast thermal cycle of heating and cooling of the insert and calandria tube in the rolled joint region while applying axial load to the calandria tube. Though rolled joint detachment by induction heating technique has been in use in CANDU reactors for removal of pressure tubes and calandria tubes, the present design incorporates a liquid nitrogen for faster cooling and simultaneous application of load with a gripping module for detachment and removal of calandria tube and the insert from the tube sheet of end shield in shorter time. This paper describes the methodology of rolled joint detachment, challenges involved in the design, features of the detachment system, findings of experimental trials and observations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effect of He seeding on hydrogen isotope permeation in tungsten by H-D mixed plasma exposure

Hydrogen (H) and deuterium (D) permeation fluxes for tungsten (W) by H-D mixed plasma were studied to clarify the hydrogen isotope effect on permeation by a newly designed plasma driven permeation (PDP) device at Shizuoka University. A mixed H-D plasma was produced by introducing H and D gasses with various ratios. The atomic ratio and permeation flux in the plasma were measured during the experiments. It was found that the H:D atomic ratio in the plasma was almost proportional to the introduced H:D gas ratio. When single species of H or D was irradiated, the H permeation rate showed approximately 1.6 times as high as that of D. Under H-D mixed plasma irradiation, the highest HD permeation rate was observed when the atomic ratio of H:D in the plasma was 50:50. In addition, the effect of He seeding on H-D mixed plasma driven permeation behavior was also evaluated. The recycling of hydrogen isotopes on the upstream side was enhanced due to the formation of He bubbles near the surface, which would prevent the dissolution of hydrogen isotopes into bulk W and enhance the reflection process during plasma exposure. H and D permeation fluxes were clearly reduced by seeding He in H-D mixed plasma. At lower temperature (~723 K), the ratio of steady permeation fluxes of H and D was about 75 : 25, confirming the high permeation flux of H . These results have demonstrated a significant hydrogen isotope effect, even if He was seeded or not. As the temperature increased, H and D permeation fluxes approached unity at 923 K. Therefore,this indicates that the hydrogen isotope effect was determined by the combination of recycling / reflection at or beneath the surface, which will be controlled by the temperature during plasma exposure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quality assurance of asymmetric jaw alignment using 2D diode array

Purpose: A method using a 2D diode array is proposed to measure the junction gap (or overlap) and dose with high precision for routine quality assurance of the asymmetric jaw alignment.Methods: The central axis (CAX) of the radiation field was determined with a 15 × 15 cm{sup 2} photon field at four cardinal collimator angles so that the junction gap (or overlap) can be measured with respect to the CAX. Two abutting fields having a field size of 15 cm (length along the axis parallel to the junction) × 7.5 cm (width along the axis perpendicular to the junction) were used to irradiate the 2D diode array (MapCHECK2) with 100 MU delivered at the photon energy of 6 MV. The collimator was slightly rotated at 15° with respect to the beam central axis to increase the number of diodes effective on the measurement of junction gap. The junction gap and dose measured in high spatial resolution were compared to the conventional methods using an electronic portal imaging device (EPID) and radiochromic film, respectively. In addition, the reproducibility and sensitivity of the proposed method to the measurements of junction gap and dose were investigated.Results: The junction gap (or overlap) and dose measured by MapCHECK2 agreed well to those measured by the conventional methods of EPID and film (the differences ranged from −0.01 to 0 cm and from −1.34% to 0.6% for the gap and dose, respectively). No variation in the repeat measurements of the junction gap was found whereas the measurements of junction dose were found to vary in quite a small range over the days of measurement (0.21%–0.35%). While the sensitivity of the measured junction gap to the actual junction gap applied was the ideal value of 1 cm/cm as expected, the sensitivity of the junction dose to the actual junction gap increased as the junction gap (or overlap) decreased (maximum sensitivity: 201.7%/cm).Conclusions: The initial results suggest that the method is applicable for a comprehensive quality assurance of the asymmetric jaw alignment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correlation of Radiation Dosage With Mechanical Properties of Thin Films

The objective of this investigation was to examine the relationship between irradiation level (proton dose), microstructure, and stress levels in chemical vapor deposited diamond and polysilicon film using crosssectioned specimens. However, the emphasis was placed on the diamond specimen because diamond holds much promise for use in advanced technologies. The use of protons allows not only the study of the charged particle that may cause the most microstructural damage in Earth-orbit microelectromechanical systems (MEMS) devices, but also allows the study of relatively deeply buried damage inside the diamond material. Using protons allows these studies without having to resort to megaelectronvolt implant energies that may create extensive damage due to the high energy that is needed for the implantation process. Since 1 MEMS devices operating in space will not have an opportunity to reverse radiation damage via annealing, only nonannealed specimens were investigated. The following three high spatial resolution techniques were used to examine these relationships: (I) Scanning electron microscopy, (2) micro-Raman spectroscopy, and (3) micro x-ray diffraction.

Newton, R. L.↗

Texas Instruments' virtual phase charge-coupled device (CCD) imager operated in the frontside electron-bombarded mode

The present investigation is concerned with the suitability of the virtual phase CCD imager for frontside detection of electrons up to 25 keV. The investigation has the objective to determine if the imager can be used in the frontside mode with a photocathode to detect very low light levels in astronomical applications, the ultimate goal being individual photon detection. It is found that the standard virtual phase imager will function properly over an extended period at low levels of 20 kV electron irradiation consistent with photon counting applications. The imager can detect individual primary electrons with nearly 100 percent efficiency. However, further studies are needed to determine the mechanisms for the flat band shifts so that the imager design may be modified to eliminate or at least reduce them.

Everett, P.↗

Beyond Epitaxy: Ion Implantation as a Tool for Orbital Engineering

Manipulating electronic orbital states in quantum materials provides a powerful means of controlling their physical properties and technological functionality. Here, we demonstrate that orbital populations in strongly correlated oxide thin films can be continuously and reversibly tuned through postsynthesis He ion implantation. Using LaNiO 3 as a model system, we show that the orbital preference can be systematically adjusted from favoring in-plane d x 2 –y 2 occupation toward out-of-plane d z 2 states through precise control of ion fluence. Unlike conventional heteroepitaxial approaches that lock in orbital configurations during growth, this strain-doping technique enables continuous orbital tuning and the selective modification of specific film regions after device fabrication. We demonstrate the practical impact of this control by achieving a 7-fold enhancement in oxygen reduction reaction catalysis. This work establishes ion implantation as a powerful approach for orbital engineering that complements existing synthesis-based strategies while offering unique advantages for both basic research and device development.

Doping↗

Total-Ionizing-Dose Effects on Read Noise of MLC 3-D NAND Memories T

This paper analyzes the total ionizing dose (TID) effects on noise characteristics of commercial multi-level-cell (MLC) 3-D NAND memory technology during the read operation. Additionally, the chips were exposed to a Co-60 gamma-ray source for up to 100 krad(Si) of TID. We find that the number of noisy cells in the irradiated chip increases with TID. Bit-flip noise was more dominant for cells in an erased state during irradiation compared to programmed cells.

3-D NAND Flash↗

Upgrade and benchmarking of a 4D treatment planning system for scanned ion beam therapy

Purpose: Upgrade and benchmarking of a research 4D treatment planning system (4DTPS) suitable for realistic patient treatment planning and treatment simulations taking into account specific requirements for scanned ion beam therapy, i.e., modeling of dose heterogeneities due to interplay effects and range changes caused by patient motion and dynamic beam delivery. Methods: The 4DTPS integrates data interfaces to 4D computed tomography (4DCT), deformable image registration and clinically used motion monitoring devices. The authors implemented a novel data model for 4D image segmentation using Boolean mask volume datasets and developed an algorithm propagating a manually contoured reference contour dataset to all 4DCT phases. They further included detailed treatment simulation and dose reconstruction functionality, based on the irregular patient motion and the temporal structure of the beam delivery. The treatment simulation functionality was validated against experimental data from irradiation of moving radiographic films in air, 3D moving ionization chambers in a water phantom, and moving cells in a biological phantom with a scanned carbon ion beam. The performance of the program was compared to results obtained with predecessor programs. Results: The measured optical density distributions of the radiographic films were reproduced by the simulations to (-2 {+-} 12)%. Compared to earlier versions of the 4DTPS, the mean agreement improved by 2%, standard deviations were reduced by 7%. The simulated dose to the moving ionization chambers in water showed an agreement with the measured dose of (-1 {+-} 4)% for the typical beam configuration. The mean deviation of the simulated from the measured biologically effective dose determined via cell survival was (617 {+-} 538) mGy relative biological effectiveness corresponding to (10 {+-} 9)%. Conclusions: The authors developed a research 4DTPS suitable for realistic treatment planning on patient data and capable of simulating dose delivery to a moving patient geometry for scanned ion beams. The accuracy and reliability of treatment simulations improved considerably with respect to earlier versions of the 4DTPS.

60 APPLIED LIFE SCIENCES↗

Technical Note: Response measurement for select radiation detectors in magnetic fields

Purpose: Dose response to applied magnetic fields for ion chambers and solid state detectors has been investigated previously for the anticipated use in linear accelerator–magnetic resonance devices. In this investigation, the authors present the measured response of selected radiation detectors when the magnetic field is applied in the same direction as the radiation beam, i.e., a longitudinal magnetic field, to verify previous simulation only data. Methods: The dose response of a PR06C ion chamber, PTW60003 diamond detector, and IBA PFD diode detector is measured in a longitudinal magnetic field. The detectors are irradiated with buildup caps and their long axes either parallel or perpendicular to the incident photon beam. In each case, the magnetic field dose response is reported as the ratio of detector signals with to that without an applied longitudinal magnetic field. The magnetic field dose response for each unique orientation as a function of magnetic field strength was then compared to the previous simulation only studies. Results: The measured dose response of each detector in longitudinal magnetic fields shows no discernable response up to near 0.21 T. This result was expected and matches the previously published simulation only results, showing no appreciable dose response with magnetic field. Conclusions: Low field longitudinal magnetic fields have been shown to have little or no effect on the dose response of the detectors investigated and further lend credibility to previous simulation only studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron-Induced Displacement Damage Effects in CCDs

We compare differences in parametric degradation for CCDs irradiated to the same displacement damage dose with 10-MeV and 50-MeV electrons. Charge transfer efficiency degradation was observed to not scale with NIEL for small signals.

Juno Mission↗

Irradiation with molecular hydrogen as an accelerated total dose hardness assurance test method for bipolar linear circuits

High dose rate irradiation with hydrogen stress is proposed as an accelerated total dose test method for bipolar linear circuits. The method is validated across process and circuit technologies with five parts that are commonly used in space: a comparator (LM193 from National Semi-conductor), a voltage regulator (HSYE-117 RH from Intersil), a voltage reference (LT1019 from Linear Technology), a JFET input op amp (OP42 from Analog Devices) and a temperature transducer (AD590 from Analog Devices). The testing technique could rapidly establish an upper bound to the low dose rate response of parts in space and help with the part selection process in the design phase of a mission. The technology dependence and the viability of this technique are qualitatively explored using a physical model describing the dose rate response and the effect of hydrogen in bipolar technologies. The model uses four core processes: 1) space charge effects, 2) free electron/hole pair recombination, hole-hydrogen defect reactions in the oxides and 4) proton depassivation of dangling bonds at the Si/SiO2 interface. Radiation hardness assurance implications are discussed.

Pease, Ron↗

Heat flux solarimeter

The solarimeter presented in this work is easy to assemble. It is calibrated and its performance is validated by means of Hottel's method. Finally, the curves obtained with this solarimeter are compared to the ones obtained with a commercial solarimeter. This device is based on the evaluation of the heat flow in a metal rod. In consequence, measurements are not affected by ambient temperature variations. On the other hand, there is a linear relationship between the temperatures measured at the rod ends and the incident radiation, as can be concluded both from the theory of its operation and the calibration lines obtained. The results obtained from the global irradiance measurements in the area of Los Polvorines (Buenos Aires Province), together with a preliminary evaluation of the solarimeter's response time, are presented in this work. (author)

14 SOLAR ENERGY↗

Neutron detection using boron gallium nitride semiconductor material

In this study, we developed a new neutron-detection device using a boron gallium nitride (BGaN) semiconductor in which the B atom acts as a neutron converter. BGaN and gallium nitride (GaN) samples were grown by metal organic vapor phase epitaxy, and their radiation detection properties were evaluated. GaN exhibited good sensitivity to α-rays but poor sensitivity to γ-rays. Moreover, we confirmed that electrons were generated in the depletion layer under neutron irradiation. This resulted in a neutron-detection signal after α-rays were generated by the capture of neutrons by the B atoms. These results prove that BGaN is useful as a neutron-detecting semiconductor material.

36 MATERIALS SCIENCE↗

High-resolution magnetic field fingerprinting of integrated circuit activity with a quantum diamond microscope

Devices for determining a state of a magnetic field-generating article are provided. In various embodiments, a device comprises: a single crystal diamond having a plurality of NV centers, the single crystal diamond configured to be disposed adjacent to a magnetic field-generating article, and configured to generate a fluorescent signal in response to being illuminated by a light source; a coherent light source configured to generate a light beam directed at the single crystal diamond; a microwave (MW) radiation source configured to irradiate the single crystal diamond with a MW signal; a magnetic field source configured to apply a bias magnetic field to the single crystal diamond; a photosensor configured to collect the fluorescent signal generated by the single crystal diamond; and a computing node operatively coupled to each of the coherent light source, the MW radiation source, the magnetic field source, and the photosensor.

Turner, Matthew James↗

Optical, ferroelectric, and piezoresponse force microscopy studies of pulsed laser deposited Aurivillius Bi₅FeTi₃O₁₅ thin films

Bi₅FeTi₃O₁₅ (BFTO) based Aurivillius ferroelectric thin films were fabricated on strontium ruthanate coated amorphous fused silica substrates using pulsed laser deposition technique. Optical, ferroelectric, and piezoresponse properties of these thin films were investigated. The estimated refractive index (n) and extinction coefficient (k) for these films were in the range from 2.40 to 2.59 and 0.012 to 0.19, respectively. The bandgap of the BFTO thin layers was estimated to be 2.88 eV. Domain switching and hysteresis loops of BFTO films were studied utilizing piezoresponse force microscopy (PFM). The measured apparent polarization (P{sub r}) and coercive field (E{sub c}) for the samples were 20 μC/cm² and 250 kV/cm, respectively. The amplitude and phase hysteresis curves obtained from PFM characterization reveal that these films can be switched below 5 V. These results suggest that BFTO in thin film form is a promising material for photo ferroelectric and optoelectronic devices applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

MEXIICO: a new equipment to study the pressure impact on the irradiated fuel behavior

The new MEXIICO experimental loop has recently been started in the LECA-STAR hot-cell facility of the CEA Cadarache. It is dedicated to the understanding of the basic mechanisms occurring in nuclear fuels during nuclear reactor power transients and accidental situations. Under such conditions the nuclear fuels are submitted to thermo-mechanical stresses. These stresses play a major role on fission product release and fuel fragmentation. Evaluating such fuel behavior represents a key issue for reactor safety analyses. In the first part of the paper, we describe the complete MEXIICO device, which main component is a hot isostatic press allowing to perform analytical experiments in the [20 -1600 C. degrees / 10 MPa - 160 MPa] region. As shown by simulations (ALCYONE fuel performance code), the upper value of the pressure (160 MPa) is consistent with the one experienced by fuels under nuclear power transients. We also present the experimental loop starting from the argon pressurized feed-line, the furnace and its associated instrumentation and the exhaust line equipped with specific valves and flowmeters controlling the pressure and flowrate. We then focus on the gamma spectrometry measurement which allows recording the fission gas release kinetics. In the second part of the paper, we detail the capability of the MEXIICO device to provide new experimental data regarding the influence of pressure on the fission gas release and fuel fragmentation, and to determine a pressure threshold above which fission gas release and fuel fragmentation may be inhibited. This device also allows investigating the impact of pressure on the microstructure evolution, coupling it with post-test microanalysis examinations: this procedure will allow characterizing the effect of temperature and pressure on the bubble evolution and interconnection. Evolutions of the fuel modeling, needed to simulate correctly these new experimental data, will be also presented. In the last section of the paper, we present the commissioning tests of the MEXIICO device showing the good reproducibility of the tests performed first in conventional laboratory and then in hot-cell laboratory. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

FISSION NEUTRON IRRADIATION EFFECT ON INTERLAMINAR SHEAR STRENGTH OF CYANATE ESTER RESIN GFRP AT RT AND 77 K

A glass fiber reinforced plastic (GFRP) with cyanate ester resin was fabricated and neutron irradiation tests up to 1x10{sup 22} n/m{sup 2} of fast neutron with over 0.1 MeV energy were carried out in fission reactor. The fabrication process of cyanate ester GFRP was established and a collaboration network to perform investigations on irradiation effect of superconducting magnet materials was constructed. Three kinds of samples were fabricated. The first was CTD403 GFRP made by NIFS, the second was (cyanate ester+epoxy) GFRP provided by Toshiba, and the last was CTD403 GFRP made by Toshiba. The irradiation was carried out at JRR-3 in Japan Atomic Energy Agency using Rabbit capsules.After the irradiation, short beam tests were conducted at room temperature and 77 K and interlaminar shear strength (ILSS) was evaluated. The irradiation of 1x10{sup 21} n/m{sup 2} increased ILSS a little but 1x10{sup 22} n/m{sup 2} irradiation decreased ILSS to around 50 MPa. These tendencies were observed in all three kinds of GFRPs.

36 MATERIALS SCIENCE↗