Search NASA⌕ Search

SEARCH · Search NASA

Results for “Instrument Development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,261 records · Page 70

Cable aging and condition monitoring of radiation resistant nano-dielectrics in advanced reactor applications

Cross-linked polyethylene (XLPE) nanocomposites have been developed in an effort to improve cable insulation lifetime to serve in both instrument cables and auxiliary power systems in advanced reactor applications as well as to provide an alternative for new or retro-fit cable insulation installations. Nano-dielectrics composed of different weight percentages of MgO & SiO 2 have been subjected to radiation at accumulated doses approaching 20 MRad and thermal aging temperatures exceeding 100 C. Depending on the composition, the performance of the nanodielectric insulation was influenced, both positively and negatively, when quantified with respect to its electrical and mechanical properties. For virgin unradiated or thermally aged samples, XLPE nanocomposites with 1wt.% SiO 2 showed improvement in breakdown strength and reduction in its dissipation factor when compared to pure undoped XLPE, while XLPE 3wt.% SiO 2 resulted in lower breakdown strength. When aged in air at 120 C, retention of electrical breakdown strength and dissipation factor was observed for XLPE 3wt.% MgO nanocomposites. Irrespective of the nanoparticle species, XLPE nanocomposites that were gamma irradiated up to the accumulated dose of 18 MRad showed a significant drop in breakdown strength especially for particle concentrations greater than 3 wt.%. Additional attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy measurements suggest changes in the structure of the XLPE SiO 2 nanocomposites associated with the interaction of silicon and oxygen. Discussion on the relevance of property changes with respect to cable aging and condition monitoring is presented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Method for Hot Real-Time Sampling of Gasification Products

The Thermochemical Process Development Unit (TCPDU) at the National Renewable Energy Laboratory (NREL) is a highly instrumented half-ton/day pilot scale plant capable of demonstrating industrially relevant thermochemical technologies from lignocellulosic biomass conversion, including gasification. Gasification creates primarily Syngas (a mixture of Hydrogen and Carbon Monoxide) that can be utilized with synthesis catalysts to form transportation fuels and other valuable chemicals. Biomass derived gasification products are a very complex mixture of chemical components that typically contain Sulfur and Nitrogen species that can act as catalysis poisons for tar reforming and synthesis catalysts. Real-time hot online sampling techniques, such as Molecular Beam Mass Spectrometry (MBMS), and Gas Chromatographs with Sulfur and Nitrogen specific detectors can provide real-time analysis providing operational indicators for performance. Sampling typically requires coated sampling lines to minimize trace sulfur interactions with steel surfaces. Other materials used inline have also shown conversion of sulfur species into new components and must be minimized. Sample line Residence time within the sampling lines must also be kept to a minimum to reduce further reaction chemistries. Solids from ash and char contribute to plugging and must be filtered at temperature. Experience at NREL has shown several key factors to consider when designing and installing an analytical sampling system for biomass gasification products. They include minimizing sampling distance, effective filtering as close to source as possible, proper line sizing, proper line materials or coatings, even heating of all components, minimizing pressure drops, and additional filtering or traps after pressure drops.

09 BIOMASS FUELS↗

Implementation of a System of Gamma Imagers for Measuring Plutonium Holdup

The Surplus Plutonium Disposition (SPD) project is an effort to dilute and dispose of many tonsof weapons grade plutonium. This work will take place in a shielded glovebox to protect workers fromradiological dose. Accurate measurements of the holdup, or material left behind, in the gloveboxes is im-portant for Nuclear Material Control and Accountancy, worker dose minimization, criticality safety, andprocess monitoring. Shielding around the gloveboxes presents an obstacle for the traditional GeneralizedGamma Holdup (GGH) method. The uncertainties associated with that method, at around 28%, arealso detrimental since the amount of holdup must be kept below an established limit with a high level ofconfidence.Passive gamma-ray imaging provides a more complete depiction of the distribution of radioactivematerials. Recent refinement of the method has demonstrated that quantitative information can beextracted from the images with a well-characterized system. A permanently installed system of gamma-ray imagers is currently being developed to measure plutonium holdup in the SPD gloveboxes. Thispaper will report on progress with the development of this system.This application requires that the features of current commercially available instruments from H3Dand PHDS, optimized for measurement performance in a mobile application, be translated into theconstraints of the operational environment with fixed installations. The interaction between facilityconstraints and measurement capabilities will be addressed.A series of measurements with plutonium sources in a mocked-up glovebox geometry with imagersmounted above the ceiling of the glovebox have been taken. Imager performance with respect to angularresolution, minimum measurement time for quantification, and signal-to-noise ratio with a multitudeof sources will be evaluated for those measurements. A series of prototypes of user interfaces will bepresented for display of the data to its various consumers for the purposes of Nuclear Material Controland Accountancy, worker dose minimization, criticality safety, and process monitoring.

Schmitt, Kyle↗

Security-informed safety: integrating security within the safety demonstration of a smart device - 157

Safety and security engineering have, over the years, developed their own regulations, standards, cultures, and practices. However, there's a growing realisation that security is closely connected to safety. Safety must be security-informed: if a safety-critical system isn't secure, it isn't safe. A safety demonstration is incomplete and unconvincing unless it considers security. In our work for government and industry, we have used the Claims, Arguments, Evidence (CAE) framework to analyse the impact of security on a safety justification or safety case and identified the significant changes needed to address security explicitly. This will impact the design and implementation process as well as the assurance and V and V approach. In this paper we discuss the impact of integrating security when developing a safety demonstration of a smart device. A smart device is an instrument, device or component that contains a microprocessor (and therefore contains both hardware and software) and is programmed to provide specialised capabilities, often measuring or controlling a process variable. Examples of smart devices include radiation monitors, relays, turbine governors, uninterruptible power supplies and heating ventilation, and air conditioning controllers. (authors)

42 ENGINEERING↗

BatteryPro: A Python Toolkit for Battery Data Analysis and Machine Learning Predictions

Analyzing battery test data for research & development can be time-consuming since battery tests often run on the order of months to years, generating large volumes of data. BatteryPro is a comprehensive Python package and software designed to facilitate advanced analysis and performance predictions for battery test data. Developed for battery researchers, it supports data types from widely used battery testing instruments, including MACCOR and Biologic cycling systems. The software provides a variety of tools for extracting and plotting key battery parameters such as time, voltage, capacity, current, and pressure. In addition to its extensive data analysis capabilities, BatteryPro features a dedicated machine learning module that employs a Bayesian Gaussian Mixture Model (GMM) to predict battery performance and degradation. Users can generate synthetic capacity fade data, calculate fade metrics, and leverage predictive models to forecast long-term battery behavior. The software's graphical user interface (GUI) enhances usability, allowing researchers to upload, merge, and analyze multiple data files with full customizability. The GUI also supports machine learning predictions, enabling users to fit models and make predictions based on selected data and parameters. BatteryPro is built using QtDesigner, scikit-learn, matplotlib, and pandas, ensuring a high level of customization, flexibility, and accuracy in battery data analysis. This tool aims to empower researchers with the ability to perform detailed battery analysis and make informed predictions, ultimately advancing the field of battery research.

25 - ENERGY STORAGE↗

The Mount Wilson Observatory S-index of the sun

The most commonly used index of stellar magnetic activity is the instrumental flux scale of singly ionized calcium H and K line core emission, S, developed by the Mount Wilson Observatory (MWO) HK Project, or the derivative index R{sub HK}{sup ′}. Accurately placing the Sun on the S scale is important for comparing solar activity to that of the Sun-like stars. We present previously unpublished measurements of the reflected sunlight from the Moon using the second-generation MWO HK photometer during solar cycle 23 and determine cycle minimum S{sub 23,min}=0.1634±0.0008, amplitude ΔS{sub 23}=0.0143±0.0012, and mean 〈S{sub 23}〉=0.1701±0.0005. By establishing a proxy relationship with the closely related National Solar Observatory Sacramento Peak calcium K emission index, itself well correlated with the Kodaikanal Observatory plage index, we extend the MWO S time series to cover cycles 15–24 and find on average 〈S{sub min}〉=0.1621±0.0008, 〈ΔS{sub cyc}〉=0.0145±0.0012, 〈S{sub cyc}〉=0.1694±0.0005. Our measurements represent an improvement over previous estimates that relied on stellar measurements or solar proxies with non-overlapping time series. We find good agreement from these results with measurements by the Solar-Stellar Spectrograph at Lowell Observatory, an independently calibrated instrument, which gives us additional confidence that we have accurately placed the Sun on the S-index flux scale.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of a bayesian belief network model for the software reliability assessment of nuclear digital I and C safety systems - 206

Since the digital instrumentation and control systems are expected to play an important role for the safety systems in nuclear power plants (NPPs), the need has emerged to not only establish a basis for incorporating software behavior into digital I and C system reliability models, but also to quantify the failure probability of the software used in NPP digital protection systems. In this study, a Bayesian belief network (BBN) model is developed to quantitatively assess software reliability by estimating the number of faults in a software program considering its software development life cycle (SDLC). The model structure and parameters are established based on the information applicable to NPP safety-related systems and the evidence used to construct and quantify the BBN model was collected from three stages of expert elicitation. The software failure probability is estimated from the number of residual defects in a software program at the end of SDLC phase. As a case study, the BBN model was applied to quantify the software reliability of a typical digital protection software having the size of 50 function points and having the Medium development and validation and verification (V and V) qualities. The developed model can be applied to estimate the failure probability for both developing and deployed safety-related NPP software, and such results can be used to evaluate the quality of the digital I and C systems in addition to estimating potential reactor risk due to software failure. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Integration of Local Knowledge is a Key for the Remediation Success of Legacy Uranium Mine Sites - 19564

A key to success, during all aspects of the remediation process on legacy uranium sites, and easily transferable between countries and projects, is the integration of local knowledge. However, before this knowledge can be integrated, local trust and project understanding must be developed. Local trust and project understanding can only be developed through a principle-centred approach to a shared project vision, two-way communication of knowledge, alignment of project goals, and understanding the local needs early in the remediation process. Once public confidence is obtained, local trust and project understanding must be maintained throughout the entirety of the remediation process. Project understanding is an ongoing endeavor that needs continuous communication and varied methods to succeed. During the management of assessment, remediation, and post remediation monitoring on the Saskatchewan Research Council's CLEANS project (remediation of 37 legacy uranium mine sites in Northern Saskatchewan, Canada), integration of local knowledge has been an instrumental tool attributing to success. During site assessment, integration of local knowledge has included the development and implementation of land use surveys to determine realistic travel and occupancy on and adjacent to these legacy sites, and site specific traditional knowledge and land use studies that have contributed to the development of a detailed knowledge of local land use, resource utilization, country food intake, and human history of the sites. The local knowledge gained during the assessment process is invaluable as it provides information required to support remediation planning, such as: valued ecosystem components, human trophic utilization, length of site occupancy, cultural value assessment, and future land use considerations. During remediation planning, local and traditional knowledge can also be incorporated through determination of plant species suitability for revegetation, development and selection of remediation options, and setting realistic sustainable development targets for local project inclusion. During site remediation operations, local involvement can be utilized through direct labour and equipment, cultural resource monitoring (i.e. archaeological and heritage protection), local logistics and historic information transfer, and stakeholder communications and engagement support. Post remediation, local involvement is an efficient mechanism for long-term monitoring, and care and maintenance activities. Although there may be differences between countries, regions and sites, the remediation process on legacy uranium mines can universally be more successful through the integration of local knowledge; while developing rights/stakeholder engagement and capacity building. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of Surrogate Molten Salt Reactor Aerosol Streams

Measuring the aerosol evolution from MSRs is important for monitoring the off-gas system of the reactor and is particularly important for detecting off-normal conditions. In a molten salt reactor (MSR) accident scenario, an aerosol release would be a major factor in the source term. This aerosol stream would likely be generated from a breach in the cover gas system, which causes particles produced from fission itself to escape, or from a salt spill that produces aerosols through splashing and secondary reactions. The particle size of the produced aerosols is anticipated to vary greatly and range from 0.01 to 10 µm. The transport of these aerosols would be dependent on the particle size. A better understanding of aerosol generation, size, and monitoring methods are needed to inform estimation and mitigation of potential aerosolized source terms from MSRs. While salt spill experiments are being performed at Argonne National Laboratory, the development of aerosol characterization and monitoring methods are being developed at Oak Ridge National Laboratory. To generate prototypic aerosols for use in testing monitoring instruments and mitigation methods, a surrogate aerosol stream was produced with a Collison nebulizer, and the particle size distributions were measured with a cascade impactor. The results demonstrated that by changing the nebulizer pressure, the aerosol particle size distribution can be adjusted to best match the region of interest for experiments with higher pressures, driving the particle size down. However, nearly all aerosols formed exceeded 1 µm in diameter, providing a lower bound for the surrogate aerosol stream. In addition to verifying the applicability of this surrogate aerosol stream, this work has shown that a laser induced breakdown spectroscopy monitoring system that is under development is resilient to changes in particle sizes, increasing its robustness for off-gas monitoring.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Compact, Broad-Band Hyperspectral SpectroRadiometer (Final Report)

The Phase I effort has laid the foundation for developing a complete, high-performance hyperspectral imaging system based on a patented approach. Detailed optical modeling has been performed to identify an optimal design that promises excellent imaging, low stray-light, and large signal-to-noise ratios across the full spectral range of 350-2500 nm. Vibration analysis indicates the instrument’s primary optics will be stable when deployed in high-vibration environments such as onboard a UAV, and a mechanical design has been developed. A two-step development plan has been formulated to minimize risk. In the first step, a deployable prototype instrument will be built that provides full performance but will utilize a somewhat heavy, but proven, data acquisition system. This will leave sufficient time and resources to address problems that may arise and incorporate a more advanced data acquisition system during the second step, plus leave time and resources to make other improvements identified during testing done during the first step. In summary, the effort will lead to an advanced instrument for vegetation monitoring, which may find applications in agriculture, pipeline monitoring, and it will find applications for a broad range of research including work devoted to understanding of the carbon cycle.

54 ENVIRONMENTAL SCIENCES↗

Safety-Related Instrumentation and Control Pilot Upgrade (Initial Scoping Phase Implementation Report)

This research report (1) describes the process followed and products developed during the SR I&C Pilot Project Initial Scoping Phase, and (2) captures lessons learned. Exelon Generation and LWRS collaborated to develop a Digital Transformation Strategy as part of a larger Advanced Concept of Operations. The proposed SR I&C Pilot Upgrade provides a foundation stone for this Digital Transformation that will improve plant safety, reliability, and operational performance while lowering plant Total Cost of Ownership (TCO). Initial Scoping Phase activities for this Pilot Project have been performed in accordance with industry processes that have been adapted to better support digital upgrades. These processes include IP-ENG-001, Standard Design Process (SDP), NISP-EN-04, Standard Digital Engineering Process (SDEP), and Electric Power Research Institute (EPRI) Report 3002011816, Digital Engineering Guide (DEG). Completing Initial Scoping Phase Engineering and Operations, Licensing, and Project Management Activities was necessary to sufficiently bound the scope, schedule, and estimated cost of the Project to enable utility management to authorize moving into the Conceptual Design Phase. A significant finding of the Business Case Analysis (BCA) methodology developed and applied as part of this effort was that the growth rate of material costs for sustaining the operation of obsolete SR I&C equipment is accelerating. This directly contributed to the Project Economic Analysis created to justify continuing the Project. Project Initial Scoping Phase lessons learned have also been captured to assist the larger industry in understanding the Digital Transformation Strategy and SR I&C Pilot Project Initial Scoping Phase efforts. This is in keeping with the public/private partnership that has been established between the Department of Energy (DOE) and Exelon for this effort with engagement from the NRC. By addressing first-of-a-kind (FOAK) risks and capturing lessons learned, the SR I&C Pilot Upgrade Project addresses technical, regulatory, and business risks to enable subsequent implementers of similar upgrade.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development and Operation of PIP-II Injector Test, SSR1 Cryomodule, 325 MHz Amplifiers

The PIP-II Injector Test (PIP2IT) has successfully accelerated ionized hydrogen up to 17MeV through a superconducting, single spoke resonator (SSR1) cryomodule at Fermi National Accelerator Laboratory (FNAL). Each of the SSR1 cavities is tuned to 325MHz and requires up to 6 kW of RF power to accelerate 2mA of ionized hydrogen at the design gradients. RF power amplifiers, specialized for SRF cavity beam operations, were designed by Bhabha Atomic Research Center (BARC) and constructed in a collaboration between the BARC in Mumbai, India and the Electronics Corporation of India Limited (ECIL) in Hyderabad, India. The RF amplifiers meet the specifications and requirements mutually approved between BARC and FNAL. They operate at 325 MHz with a linear power output of 7 kW in both CW and pulse mode. The amplifiers are compatible with the FNAL accelerator personnel safety system and the cavity protection interlocks. Access to controls and internal diagnostic instrumentation are compatible with EPICS control standards. This paper gives details about RF power amplifier development within the Department of Atomic Energy (DAE), India and the operational details with PIP2IT at FNAL.

43 PARTICLE ACCELERATORS↗

Versailles Project on Advanced Materials and Standards interlaboratory study on intensity calibration for x-ray photoelectron spectroscopy instruments using low-density polyethylene

We report the results of a Versailles Project on Advanced Materials and Standards interlaboratory study on the intensity scale calibration of x-ray photoelectron spectrometers using low-density polyethylene (LDPE) as an alternative material to gold, silver, and copper. An improved set of LDPE reference spectra, corrected for different instrument geometries using a quartz-monochromated Al Kα x-ray source, was developed using data provided by participants in this study. Using these new reference spectra, a transmission function was calculated for each dataset that participants provided. When compared to a similar calibration procedure using the NPL reference spectra for gold, the LDPE intensity calibration method achieves an absolute offset of ~3.0% and a systematic deviation of ±6.5% on average across all participants. For spectra recorded at high pass energies (≥90 eV), values of absolute offset and systematic deviation are ~5.8% and ±5.7%, respectively, whereas for spectra collected at lower pass energies (<90 eV), values of absolute offset and systematic deviation are ~4.9% and ±8.8%, respectively; low pass energy spectra perform worse than the global average, in terms of systematic deviations, due to diminished count rates and signal-to-noise ratio. Differences in absolute offset are attributed to the surface roughness of the LDPE induced by sample preparation. We further assess the usability of LDPE as a secondary reference material and comment on its performance in the presence of issues such as variable dark noise, x-ray warm up times, inaccuracy at low count rates, and underlying spectrometer problems. In response to participant feedback and the results of the study, we provide an updated LDPE intensity calibration protocol to address the issues highlighted in the interlaboratory study. Finally, we also comment on the lack of implementation of a consistent and traceable intensity calibration method across the community of x-ray photoelectron spectroscopy (XPS) users and, therefore, propose a route to achieving this with the assistance of instrument manufacturers, metrology laboratories, and experts leading to an international standard for XPS intensity scale calibration.

36 MATERIALS SCIENCE↗

Enabling in-situ LIBS measurements of liquids and slurries

The aim of this work was to explore the use of, and further develop, a in-situ and near-real time LIBS (Laser Induced Breakdown Spectroscopy) instrument to measure liquids relevant to the Hanford site. Specifically, we investigated the feasibility of using LIBS to measure the cation composition of HLW (High Level Waste) streams. In addition, we focused on enabling continuous interrogation of those liquids using the LIBS system. For the first part, we investigated simple (sodium nitrate) solutions as well as various Hanford tank waste surrogate slurries. We showed that relevant cations (such as sodium, aluminum, magnesium, potassium) can be measured via LIBS under good conditions but the results – both quantitative and qualitative (aka reproducibility) – strongly depend on the kind and concentration of the material used. The dependence of signal intensity on concentration was also confirmed by other measurements conducted (sodium chloride and sodium nitrate in water). For the second part, we investigated the influence of varying depth and concentration of a liquid sample. We observed that for the concentrations and fill depths investigated, the liquid fill depth did not impact the emission intensity of the analyte, while concentration is confirmed to have significant effects. The results of the sample depth experiments influenced testing of waste surrogates. In addition, we focused on further developing and adapting data fitting tools in order to efficiently, accurately, and reproducibly identify the elements and materials present in a LIBS spectrum.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TRANSENSOR: Transformer Real-time Assessment INtelligent System with Embedded Network of Sensors and Optical Readout. Final Report

Utilities across the world are wrestling with evolving market dynamics, population growth and climate change. Distributed Energy Resources (DERs) such as solar photovoltaics, distributed generators and energy storage systems are becoming important parts of the U.S. energy mix. These factors are driving an increasing need for low-cost grid asset monitoring. Aside from being costly, traditional utility monitoring systems are not sufficiently robust and do not provide real-time visibility into the condition of grid assets such as transformers. Lack of accurate real-time measurements on performance has resulted in the use of lagging indicators, such as oil sample analysis. To address this need, an innovative embedded optical sensing technology, Transformer Real-time Assessment Intelligent System (TRANSENSOR) was developed, validated and demonstrated in this project. To date, TRANSENSOR has focused on transformers but is extendable to other grid assets. In addition to the technology being embedded into new transformers during manufacturing, a retrofit configuration that can be installed on existing transformers in the field was also developed. It is anticipated that the ability to retrofit existing transformers will help accelerate adoption of the underlying TRANSENSOR technology. Phase 1 of the project focused on laboratory development and qualification of the technology. Following iterations and exploration of relevant optical sensing modalities and multiplexed configurations of interest for the transformer environment, an effective candidate configuration was agreed upon, down-selected and custom-designed for embedding into General Electric (GE) network transformers. Two new GE 500 kilovolt ampere (kVA), 27 kilovolt (kV) distribution network transformers were built with embedded fiber-optic (FO) sensors and successfully qualified per industry standards at GE’s Shreveport, Louisiana facility during Phase 1 of the project. Following the successful completion of Phase 1, the team proceeded to Phase 2, which focused on a field demonstration of the technology. Over Phase 2, the first new GE transformer built with embedded fiber-optic sensors was installed in an above-ground cage and connected to the grid at Con Edison’s Astoria facility. A second transformer equipped with TRANSENSOR was installed in an underground vault. Additionally, an older (1982 year model) GE transformer in an above-ground cage was retrofitted with fiber- optic sensors and reconnected to the grid at ConEd’s facility. Analysis of data acquired from the sensors showed interesting correlations with transformer loading. Additionally, key events such as transformer low-voltage network connection, primary-side energizing, and a pressure loss event from an oil sampling were detected by the TRANSENSOR system. Online data processing/feature extraction algorithms for the second transformer in the underground vault detected key features and event alerts that were transmitted through a wireless 4G connection. The remote deployment concept showed promising results with data collection running for a total of 8 months across the three (3) GE transformers instrumented for the Phase 2 field demonstration. This sets the stage well for further development and commercialization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DRiFT - Release 2.1.0: Organic Scintillators and Gas Detectors

DRiFT (a Detector Response Function Toolkit) is LANL-developed software that post-processes output from the extensively validated radiation transport code, MCNP, and generates realistic nuclear instrumentation response. DRiFT is designed to be flexible, enabling users to specify detector type and many experimental settings, as well as accommodating the addition of their own desired features. The focus of this release is on organic scintillator, gas detector, and associated capabilities, while semiconductor features are still under development. Organic scintillators are widely used in the areas of nuclear safeguards and nuclear non-proliferation efforts. DRiFT has several diagnostic and detector physics features relevant to detailed scintillator simulations including: tracking source particle information, scintillation light production, the effects of PMT quantum efficiency and gain, and digitizer settings. Users can select responses from many scintillator and PMT types supported natively by DRiFT, or add their own by following the instructions in this document. DRiFT also has several diagnostic and detector physics features relevant to neutron gas detector simulations including: gas detector wall effects, inactive areas at the end of detector tubes, and effects of a preamplifier. We acknowledge that DRiFT is under active development, bug reports and general questions and comments should be directed to Madison Andrews, madison@lanl.gov. This manual is divided into four parts: I) An overview of DRiFT, including how to obtain and install the executable, II) A description of the detector physics related to scintillators available, III) a description of more general DRiFT features the user may find useful, and IV) a description of the test suite and examples made available with the code release.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗