Search NASASearch

SEARCH · Search NASA

Results for “220600 -- Nuclear Reactor Technology-- Research, Test & Experimental Reactors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,981 records · Page 71

Deriving the Landauer Principle From the Quantum Shannon Entropy

We derive an expression to determine the equilibrium probability distribution of a quantum state in contact with a noisy thermal environment that formally separates contributions from quantum and classical forms of probabilistic uncertainty. A statistical mechanical interpretation of this probability distribution enables us to derive an expression for the minimum free energy costs for arbitrary (reversible or irreversible) quantum state changes. In conclusion, based on this derivation, we demonstrate that–in contrast to classical systems–the free energy required to erase or reset a qubit depends sensitively on both the fidelity of the target state and on the physical properties of the environment, such as the number of quantum bath states, due primarily to the entropic effects of system-bath entanglement.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Predicting Band-Gap of Inorganic Materials Using Neuromorphic Graph Learning

Predicting properties of inorganic materials is a heavily researched topic, with several new prediction approaches emerging as competitors. One such competitor is graph neural networks, which leverage the structure of the graph to aid in the prediction process. In this work, we propose integration of neuromorphic computation into the graph neural network pipeline. We call this approach Neuromorphic Graph Learning (NGL). We utilize the NGL approach to leverage evolutionary algorithms and a novel Spike Pipeline for Raster Analysis (SPIRE) for the prediction of band gap in inorganic materials.

Mulet, Ian [University of Tennessee (UT)]

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Aerospace Battery Activities at NASA/Goddard Space Flight Center

Goddard Space Flight Center has "pioneered" rechargeable secondary battery design, test, infusion and in-orbit battery management among NASA installations. Nickel cadmium batteries of various designs and sizes have been infused for LEO, GEO and Libration Point spacecraft. Nickel-Hydrogen batteries have currently been baselined for the majority of our missions. Li-Ion batteries from ABSL, JSB, SaFT and Lithion have been designed and tested for aerospace application.

Rao, Gopalakrishna M.

Boundary Layer Analysis of Shock Tube Flows

Shock tubes offer a controlled environment to reproduce kinetic and radiative phenomena characteristic of atmospheric entry flows under ground-test conditions. The boundary layer developing behind the incident shock wave determines the available test time, influences particle residence times important for similarity scaling, and can affect radiative energy transport. In this study, we couple a quasi-1D space marcher with the compressible boundary-layer equations to numerically compute the post-shock flow in a shock frame of reference for various test gas mixtures representative of different planetary atmospheres. The solvers are individually verified against CFD simulations and analytical correlations available in the literature. Coupled solutions are computed for a finite-rate chemistry in the boundary layer and a non-catalytic isothermal wall. Results yield refined estimates of the maximum separation distance, as well as insights into concentration profiles of relevant species within the boundary layer.

Andrea Fagnani

Nonintrusive Diagnostic Strategies for Arcjet Stream Characterization

In the previous lecture, the issues related to arcjet flow modeling were introduced, and the limitations of conventional instrumentation in addressing these issues were discussed. The general level of understanding of the arcjet flows was seen to preclude the use of arcjets as aerothermodynamic test facilities beyond the current role in aerothermal material testing, despite their long test duration capability. In this section, the focus will be on new developments in spectroscopic instrumentation and techniques that can be brought to bear on the fundamental problem of arcjet stream characterization. Although a wide selection of arcjet facilities were introduced in the previous section, the discussion of nonintrusive diagnostic instrumentation will be restricted to the large-scale, segmented, constricted-arc heater facilities that are most widely used in thermal protection material testing for aerospace applications. After a brief review of the important features of arcjet flows, the topic of nonintrusive, optical diagnostics is introduced with a discussion of some of the basic aspects of radiative transitions. The lecture is then organized into two sections covering emission measurements and laser-induced fluorescence measurements. Emission measurements are presented next for different regions of arcjet flows, while the fluorescence measurements are presented for the free stream region only. Summaries are given for each of the two main sections, and observations on arcjet characterization by optical diagnostics in general are given at the end.

Douglas G Fletcher

Dark energy survey year 3 results: likelihood-free, simulation-based w CDM inference with neural compression of weak-lensing map statistics

We present simulation-based cosmological wcold dark matter (wCDM) inference using dark energy survey year 3 weak-lensing maps, via neural data compression of weak-lensing map summary statistics: power spectra, peak counts, and direct map-level compression/inference with convolutional neural networks (CNN). Using simulation-based inference, also known as likelihood-free or implicit inference, we use forward-modelled mock data to estimate posterior probability distributions of unknown parameters. This approach allows all statistical assumptions and uncertainties to be propagated through the forward-modelled mock data; these include sky masks, non-Gaussian shape noise, shape measurement bias, source galaxy clustering, photometric redshift uncertainty, intrinsic galaxy alignments, non-Gaussian density fields, neutrinos, and non-linear summary statistics. We include a series of tests to validate our inference results. This paper also describes the Gower Street simulation suite: 791 full-sky pkdgrav3 dark matter simulations, with cosmological model parameters sampled with a mixed active-learning strategy, from which we construct over 3000 mock dark energy survey lensing data sets. For wCDM inference, for which we allow –1 < w < –$\frac{1}{3}$⁠, our most constraining result uses power spectra combined with map-level (CNN) inference. Using gravitational lensing data only, this map-level combination gives Ω m = 0.283$^{+0.020}_{–0.027}$⁠, S 8 = 0.804$^{+0.025}_{–0.017⁠}$, and w < –0.80 (with a 68 per cent credible interval); compared to the power spectrum inference, this is more than a factor of two improvement in dark energy parameter (Ω⁠ DE , w⁠) precision.

79 ASTRONOMY AND ASTROPHYSICS

Performance of AEA 80 Ah Battery Under GEO Profile

To date completed three Solar Dynamic Observatory SDO real-time eclipse seasons. Sony 18650HC has a low rate of capacity fade under GEO cycling regime. Real time test results correlate with accelerated GEO lifetest data and AEA capacity fade prediction tool. This data, together with other AEA test data, justify the SDO Project decision to baseline Lithium-Ion chemistry for the spacecraft battery.

Russel, N.

Factors Influencing Gas Evolution from High‐Nickel Layered Oxide Cathodes in Lithium‐Based Batteries

Abstract Gas evolution from high‐nickel layered oxide cathodes (>90% Ni) remains a major issue for their practical application. Gaseous species, such as CO 2 , O 2 , and CO, that are evolved at high states of charge (SOC) worsen the overall safety of batteries, as pressure build‐up within the cell may lead to cell rupture. Since these gasses are produced during cathode degradation, tracking the formation of gasses is also important in diagnosing cathode failure. Online electrochemical mass spectrometry (OEMS) is a powerful in situ technique to study gas evolution from the cathode during high‐voltage charge. However, the differences in the OEMS experimental setups between different groups make it challenging to compare results between groups. In this perspective, the various factors that influence gas evolution based on the OEMS results collected in this group are presented. The focus is on the conditions that lead to gas release, with a particular emphasis on reactive oxygen formation and subsequent chemical reactions with the electrolyte. Promising strategies, such as electrolytes, compositional tuning, and surface coatings that are effective at suppressing gas evolution from the cathode are highlighted. Critical insights into mitigating cathode degradation and gas evolution are provided to guide the development of safer, high‐energy batteries.

Chemistry

Nasa’S Development of Merino - A New Family of Advanced, Low-Cost, Non-Woven Ablative Tps Materials

The Mars Exploration Program (MEP) and NASAs Space Technology Mission Directorate (STMD) are investing in approaches to reduce the cost and increase the frequency of future Mars missions while also seeking to help emerging commercial space companies which have an immediate need to demonstrate their capability to return samples from space - at a fraction of the cost of a conventional NASA mission. Of particular interest and relevance to commercial space and low-cost Mars, is the work developing and advancing MERINO-LD, an ablative carbon/phenolic blanket that is ~75% faster to produce with an estimated ~75% reduction in cost when compared to rigid PICA or Conformal-PICA TPS.

Matthew Gasch

Strain and Defect-Tailored Magnetotransport in NiCo 2 O 4 Thin Films and Freestanding Membranes

Magnetic spinel NiCo 2 O 4 is promising for developing spintronic applications due to its high magnetic Curie temperature, high spin polarization, fast spin dynamics, and strain-tunable magnetic anisotropy, while its electronic and magnetic properties depend sensitively on epitaxial strain and disorder. Here, in this study, we use epitaxial NiCo 2 O 4 thin films and freestanding NiCo 2 O 4 membranes as model systems to reveal the complex interplay of strain and defects in determining the metallicity and magnetotransport properties of the ferrimagnetic spinel. NiCo 2 O 4 on perovskite substrates and NiCo 2 O 4 membranes exhibit insulating behaviors and spin canting, in sharp contrast to the metallic NiCo 2 O 4 films on spinel substrates that possess strong perpendicular magnetic anisotropy. Anisotropic magnetoresistance studies provide critical information about disorder-induced spin scattering and strain-induced tetragonal magnetocrystalline anisotropy, which is corroborated by comprehensive electron microscopy characterizations. Our study presents a promising venue for designing flexible magnetic memory, sensor, and spintronic applications.

36 MATERIALS SCIENCE

3D Woven Mid-Density Carbon Phenolic (3MDCP) Full-Scale Heatshield Development for Mars Sample Return (MSR) Earth Entry System (EES)

The Mars Sample Return (MSR) mission will be returning samples of Martian soil to Earth. The samples will be returned in the Earth Entry System (EES). The EES capsule is protected by a new thermal protection system; the 3-Dimensionally Woven, Mid-Density, Carbon Phenolic (3MDCP) material which is derived from the Heatshield for Extreme Entry Environment Technology (HEEET). The baseline 3MDCP design is a single piece thermal protection system that avoids the manufacturing and certification challenges associated with a tiled configuration. A 3MDCP heatshield begins as a flat woven preform that is formed to the final heatshield shape and then infused with phenolic resin. A NASA Ames lead team, in collaboration with Spirit Textiles (formerly TEAM Inc.), Fiber Materials Inc. (FMI, a Spirit AeroSystems Company), and Kratos SRE, has been developing and demonstrating the processes to fabricate the 3MDCP heatshield and characterize the resulting properties. The process of forming the flat woven preform into the final heatshield shape, a sphere-cone geometry with a 52.5° cone angle, involves local but substantial movement of the yarns in the weave. This results in continuous fibers across the single piece heatshield, albeit with property variations between different regions of the heatshield. This presentation will provide a high-level status of 3MDCP development for the MSR EES heatshield. This will include an overview of the manufacturing processes with an emphasis on the impact of forming on fiber orientation, material properties, and performance. Results comparing preliminary formed and flat materials will be shown. Additionally, the presentation will layout the broader plan for property testing and tie-in to aerothermal performance.

Peter Edward Marshall

Propane Activation on Pt Electrodes at Room Temperature: Quantification of Adsorbate Identity and Coverage

Abstract C−H bond activation is the first step in manufacturing chemical products from readily available light alkane feedstock and typically proceeds via carbon‐intensive thermal processes. The ongoing emphasis on decarbonization via electrification motivates low‐temperature electrochemical alternatives that could lead to sustainable chemicals production. Platinum (Pt) electrocatalysts have shown activity towards reacting alkanes; however, little is known about propane electrocatalytic activation and conditions suitable for enabling selective oxidation to valuable products. Herein, we utilize a combination of electrochemical mass spectrometry (ECMS) and density functional theory (DFT) calculations to elucidate the potential dependence of propane activation on Pt electrocatalysts. Results show a strong dependence of adsorption on the applied potential in room‐temperature aqueous acidic electrolyte, with a maximum coverage of propane‐derived adsorbates at 0.30 V vs RHE. Using charge deconvolution and deuterated experiments, the mechanism of adsorption was elucidated, and C 3 H 2 * was determined as the average dehydrogenated propane‐derived adsorbate species. DFT calculations further corroborate these results, showing that the formation of deeply dehydrogenated species is energetically accessible at room temperature. The combined theoretical and experimental findings yield insights for selective activation of paraffinic C−H bonds at room temperature, aqueous conditions—a critical step towards decarbonized chemical manufacturing.

Chemistry

Final Report Document: Microgravity Medical Eyewash B

Senior Capstone Design Team 15 has been commissioned by the National Aeronautics and Space Administration (NASA) to redesign the current microgravity eye wash station. The current design exhibits four primary limitations: single-use operation, excessive mass and volume, operational complexity requiring coordination with external systems, and dependence on frequent Earth resupply missions. Our updated eyewash design will be deployed on long-range space missions that could last multiple years. Based on these and other requirements from our customer, we have developed our updated eyewash design. Our compact, single-eye system uses capillary-driven flow and a free-floating water ball. This design allows us to eliminate pumps and bulky tubing, decreasing the mass and volume of the overall system. The containment eyecup is held to the astronaut's face with a strap, and a silicone seal prevents leakage while improving user comfort. Contaminated water is contained within a disposal bag containing wicking material to pull it back out of the eyecup after washing the eye. This system is reusable, efficient, and easy to activate quickly. We evaluated our design through calculations, microfluidic testing, and user try-on testing to verify our requirements. Our work demonstrated that steady-state flow was capable with our capillary framework, achieving 1.31 L/min. The prototype construction confirmed mass and volume reductions, and try-on-testing evaluated the ability to put on the system quickly. Almost all major design requirements were achieved, and water loss could be validated by testing in microgravity. Our design went through a number of iterations to reach the final solution presented in this report. These changes were driven by our testing and collaboration from each member of the team. Updated models optimized tube placement and geometry of the eyecup to better direct flow as it pools across the eye. Changes to our tubing bends improved capillary efficiency and increased the flow rate we were capable of achieving. And improved bracket placements adjusted the fit, comfort, and seal of the eyecup to the astronaut's face. Our capillary-based eyewash system is technically feasible and has been theoretically validated to operate effectively in microgravity conditions. Testing and analysis indicate that it can meet or exceed the required performance metrics, including flow rate and safety constraints. Overall, the design represents a viable alternative to current ISS-dependent eyewash systems for future space missions.

Jeffrey Allen

Risk Reduction Project in Pad Abort-1 Launch Vehicle Loads & Dynamics

The Pad Abort (PA-1) system includes the Launch Abort System (LAS) and the Command Module (CM). The PA-1 abort flight test will launch from the White Sands Missile Range. Prior to the ignition, the vehicle will be resting, without restraints, on a short support structure. The Launch Abort Motor will ignite and burn for less than 5 seconds before a 20 second coast. Then the LAS will separate from the CM and the CM will descend via parachute to a soil landing. The static firing of the Abort Motor (ST-1) for PA-1 Launch Vehicle resulted in unexpected higher levels that superseded the environment predictions and all the design and test loads of all subassemblies and components. A rapid project was put in place to develop the flight environments, loads and associated uncertainties for the Verification Load Cycle (VLC) of PA-1. An acoustic test and shaker test of the CM were planned and executed in support of the developments of damping and transfer functions. Instead of using the traditional structure-borne envelops, the actual ST-1 pressures and forces were used to develop the internal accelerations. The PA-1 motor was cooled to 60 Deg F using thermal conditioning to reduce the thrust profile. The plumes of the abort motor were studied to determine if the airborne environments would be reduced. The combination of all items, noted above, allowed a reduction in loads for VLC.

Sasan C Armand

Strong anharmonicity dictates ultralow thermal conductivities of type-I clathrates

Type-I clathrate solids have attracted significant interest due to their ultralow thermal conductivities and sub- sequent promise for thermoelectric applications, yet the mechanisms underlying these properties are not well understood. Here, we extend the framework of vibrational dynamical mean-field theory (VDMFT) to calculate temperature-dependent thermal transport properties of solids using a many-body Green’s function approach. When applied to a coarse-grained description of 𝑋 8 Ga 16 Ge 30 , where 𝑋= Ba, Sr, we find that nonresonant scattering between cage acoustic modes and rattling modes leads to a reduction of acoustic phonon lifetimes and thus thermal conductivities. Moreover, we find that the moderate temperature dependence of conductivities above 300 K, which is consistent with experimental measurements, cannot be reproduced by textbook perturbation theory calculations, which predict a 𝑇 −1 dependence. Therefore, we suggest that nonperturbative anharmonic effects, including four- and higher-phonon scattering processes, are responsible for the ultralow thermal conductivities of type-I clathrates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

The critical role of intrinsic defects and many-body interactions on the stability of MnBi2Te4

Intrinsic antisite defects pose a major challenge to understanding and predicting the exotic properties of the layered topological magnetic insulator MnBi2Te4 (MBT). In this work, we study the origin of the abundance of intrinsic defects in MBT, including many-body defect–defect interactions and many-body electronic correlations. Until now, ab initio methods have struggled to explain thermodynamic stability and properties influenced by defect behavior in MBT. We model native Mn–Bi antisite defects in MBT at finite temperatures using a cluster expansion that includes defect–defect interactions. To overcome the limitations of conventional density functional theory (DFT), we introduce a hybrid approach that incorporates high-accuracy quantum Monte Carlo (QMC) calculations, introducing missing correlations. This strategy allows for accurate estimation of defect energetics and finite-temperature properties. We compute the configurational free energy, defect concentration, and configurational heat capacity, revealing a second-order order–disorder phase transition near the experimental synthesis temperature. Our study provides the first theoretical insight into the thermodynamics of intrinsic defects in MBT. The negative free energy relative to pristine MBT at synthesis temperatures indicates that Mn–Bi antisite formation is thermodynamically spontaneous. We also present a broadly applicable general framework for correcting low-level theoretical theories using highly accurate many-body corrections from QMC.

Ghaffar, Abdul [ORNL] (ORCID:0000000241190168)