Lattice Element Error Solver for Modeling of Accelerators, Storage Ring, Transport Systems, and Insertion Devices
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
The construction industry faces a growing need for automation to reduce costs, improve accuracy and productivity, and address labor shortages. One area that stands to benefit significantly from automation is panelized prefabricated building envelope retrofits, which can improve a building’s energy efficiency in heating and cooling interior spaces. In this paper, we propose using cable-driven parallel robots (CDPRs), which can effectively lift and handle large objects, to install these panels. However, implementing CDPRs presents significant challenges because of their nonlinear dynamics, complex trajectory planning, and precise control requirements. To tackle these challenges, this work focuses on a new application of established control and trajectory optimization theories in a CDPR simulation of a building envelope retrofit under real-world conditions. We first model the dynamics of CDPRs, highlighting the critical role of damping in system behavior. Building on this dynamic model, we formulate a trajectory optimization problem to generate feasible and efficient motion plans for the robot under operational and environmental constraints. Given the high precision required in the construction industry, accurately tracking the optimized trajectory is essential. However, challenges such as partial observability and external vibrations complicate this task. To address these issues, a Linear Quadratic Gaussian control framework is applied, enabling the robot to track the optimized trajectories with precision. Simulation results show that the proposed controller enables precise end effector positioning with errors under 4 mm, even in the presence of external wind disturbances. Through comprehensive simulations, our approach allows for an in-depth exploration of the system’s nonlinear dynamics, trajectory optimization, and control strategies under controlled yet highly realistic conditions. The results demonstrate the feasibility of CDPRs for automating panel installation and provide insights into their practical deployment.
The “advanced tokamak” reactor concept is a leading candidate for a steady state fusion pilot plant. An advanced tokamak (AT) sustains a majority of the required plasma current with effects resulting from maintenance of the peaked pressure at the device center. This current is augmented by auxiliary current drive sources. These auxiliary actuators may consist of neutral particle beams and/or radio frequency (RF) systems such as lower hybrid current drive (LHCD) and high harmonic fast wave (HHFW) current drive using radio and microwaves from antennas. The primary focus of this work is to develop models of RF current profile control suitable for use in integrated modeling frameworks and for real-time control in experiments. Direct physics models of RF current drive can be computationally intensive. In order to achieve predictive times appropriate for the thousands of calls needed in real-time control of experiments and for use in integrated models, we will apply modern machine learning (ML) techniques to accelerate these models and interpolate their results. To generate the fast and accurate models for use in control level algorithms and integrated modeling we need to replace present models with high dimensional interpolation of their results. We will perform additional simulations across a broader parameter range for EAST and other tokamaks in different physics regimes (Alcator C-Mod, DIII-D, WEST, CFETR, ARC, ITER) and combine them into a larger database for training and testing of the ML models. Further testing of the control level models with experimental current profile data from EAST and C-Mod tokamaks will provide additional confirmation of the control level model before integration in a tokamak control system or integrated modeling suite. ML will be used to optimize the selection of training data consisting of RF current driven at different values of density profile, temperature profile, plasma current, and wavenumber. ML will also be used to facilitate classification of current drive from these input data. The output of this effort will be a validated classifier capable of determining the current drive profiles for HHFW CD and LHCD on a mille-second timescale. This will provide a breakthrough capability enabling real-time control of RF driven current profiles in experiments including ITER ICRF and use integrated modeling frameworks requiring thousands of current profile calculations in discharge simulations.
The initial federal funding for the Colorado State University Smart Grid Integration Laboratory is through a Congressionally Directed Project (CDP), DE-OE0000070 Smart Grid Integration Laboratory. The original program requested in three one-year increments for staff acquisition, curriculum development, and instrumentation all which will benefit the Laboratory. This report focuses on the initial phase of staff acquisition which was directed and administered by DOE NETL/ West Virginia under Project Officer Tom George. Using this CDP funding, we have developed the leadership and intellectual capacity for the SGIC. This was accomplished by investing (hiring) a core team of Smart Grid Systems engineering faculty focused on education, research, and innovation of a secure and smart grid infrastructure. The Smart Grid Integration Laboratory will be housed with the separately funded Integrid Laboratory as part of CSU's overall Smart Grid Integration Center (SGIC). The period of performance of this grant was 10/1/2009 to 9/30/2011 which included one no cost extension due to time delays in faculty hiring. The Smart Grid Integration Laboratory's focus is to build foundations to help graduate and undergraduates acquire systems engineering knowledge; conduct innovative research; and team externally with grid smart organizations. Using the results of the separately funded Smart Grid Workforce Education Workshop (May 2009) sponsored by the City of Fort Collins, Northern Colorado Clean Energy Cluster, Colorado State University Continuing Education, Spirae, and Siemens has been used to guide the hiring of faculty, program curriculum and education plan. This project develops faculty leaders with the intellectual capacity to inspire its students to become leaders that substantially contribute to the development and maintenance of Smart Grid infrastructure through topics such as: (1) Distributed energy systems modeling and control; (2) Energy and power conversion; (3) Simulation of electrical power distribution system that integrates significant quantities of renewable and distributed energy resources; (4) System dynamic modeling that considers end-user behavior, economics, security and regulatory frameworks; (5) Best practices for energy management IT control solutions for effective distributed energy integration (including security with the underlying physical power systems); (6) Experimental verification of effects of various arrangements of renewable generation, distributed generation and user load types along with conventional generation and transmission. Understanding the core technologies for enabling them to be used in an integrated fashion within a distribution network remains is a benefit to the future energy paradigm and future and present energy engineers.
Increasing integration of distributed solar photovoltaic (PV) into distribution networks could result in adverse effects on grid operation. Traditional model-based control algorithms require accurate model information that is difficult to acquire and thus are challenging to implement in practice. Here, this paper proposes a surrogate model-enabled grid visibility scheme to empower deep reinforcement learning (DRL) approach for distribution network voltage regulation using PV inverters with minimal system knowledge. In contrast to existing DRL methods, this paper presents and corroborates the adverse impact of missing load information on DRL performance and, based on this finding, proposes a surrogate model methodology to impute load information utilizing observable data. Additionally, a multi-fidelity neural network is utilized to construct the DRL training environment, chosen for its efficient data utilization and enhanced robustness to data uncertainty. The feasibility and effectiveness of the proposed algorithm are assessed by considering DRL testing across varying degrees of observable load information and diverse training environments on a realistic power system.
This paper presents foresee, a user-centric home energy management system that can help optimize how a home operates to concurrently meet users' needs, achieve energy efficiency and commensurate utility cost savings, and reliably deliver grid services based on utility signals. Foresee is built on a multiobjective model predictive control framework, wherein the objectives consist of energy cost, thermal comfort, user convenience, and carbon emission. Foresee learns user preferences on different objectives and acts on their behalf to operate building equipment, such as home appliances, photovoltaic systems, and battery storage. In this work, machine-learning algorithms were used to derive data-driven appliance models and usage patterns to predict the home's future energy consumption. This approach enables highly accurate predictions of comfort needs, energy costs, environmental impacts, and grid service availability. Simulation studies were performed on field data from a residential building stock data set collected in the Pacific Northwest. Results indicated that foresee generated up to 7.6% whole-home energy savings without requiring substantial behavioral changes. When responding to demand response events, foresee was able to provide load forecasts upon receipt of event notifications and delivered the committed demand response services with 10% or fewer errors. Foresee fully utilized the potential of the battery storage and controllable building loads and delivered up to 7.0-kW load reduction and 13.5-kW load increase. As a result, these benefits are provided while maintaining the occupants' thermal comfort or convenience in using their appliances.
This paper provides a comparative assessment of three economic optimal control strategies, aimed at minimizing the fuel consumption of heavy-duty trucks in a highway environment, under a representative lead vehicle model informed by traffic data. These strategies fuse a global, offline dynamic programming (DP) optimization with online model predictive control (MPC). We then show how two of the three strategies can be adapted to accommodate the presence of traffic and optimally navigate signalized intersections using infrastructure-to-vehicular (I2V) communication. The MPC optimization, which is local in nature, makes refinements to a coarsely (but globally, subject to grid resolution) optimized target velocity profile from the DP optimization. The three candidate economic MPC formulations that are evaluated include: a nonlinear time-based formulation that directly penalizes predicted fuel consumption, a nonlinear time-based formulation that penalizes braking effort as a surrogate for fuel consumption, and a linear distance-based convex formulation that maintains a tradeoff between energy expenditure and tracking of the coarsely optimized velocity profile obtained from DP. Using a medium-fidelity Simulink model, based on a Volvo truck's longitudinal and engine dynamics, we analyze the optimization's performance on four highway routes under various traffic scenarios. Results demonstrate 3.7-8.3% fuel economy improvement on highway routes without traffic and 6.5-10% on the same routes with traffic included. Furthermore, we present a detailed analysis of energy usage by "type" (aerodynamic losses, braking losses, and comparison of brake-specific fuel consumption), under each candidate control strategy.
Over the last several years, the United States (U.S.) Department of Energy (DOE) has sponsored human factors research and development (R&D) and human factors engineering (HFE) activities through its Light Water Reactor Sustainability (LWRS) program to modernize the main control rooms (MCR) of commercial nuclear power plants (NPP). Idaho National Laboratory (INL), in partnership with numerous commercial nuclear utilities, has conducted some of this R&D to enable the life extension of NPPs (i.e., provide the technical basis for the long-term reliability, productivity, safety, and security of U.S. NPPs). From these activities performed to date, a human factors meta model for U.S. NPP control room modernization can now be formulated. This paper discusses this emergent HFE meta model for NPP control room modernization, with the goal of providing an integrated high level roadmap and guidance on how to perform human factors R&D and HFE for those in the U.S. nuclear industry that are engaging in the process of upgrading their MCRs.
Heme compound II models bearing electron-deficient and -rich porphyrins, [Fe IV (O)(TPFPP)(Cl)] – (1a) and [Fe IV (O)(TMP)(Cl)] – (2a), respectively, are synthesized, spectroscopically characterized, and investigated in chemoselectivity and disproportionation reactions using cyclohexene as a mechanistic probe. Interestingly, cyclohexene oxidation by 1a occurs at the allylic C–H bonds with a high kinetic isotope effect (KIE) of 41, yielding 2-cyclohexen-1-ol product; this chemoselectivity is the same as that of nonheme iron(IV)-oxo intermediates. In contrast, as observed in heme compound I models, 2a yields cyclohexene oxide product with a KIE of 1, demonstrating a preference for C=C epoxidation. The latter result is interpreted as 2a disproportionating to form [Fe IV (O)(TMP+˙)] + (2b) and Fe III (OH)(TMP), and 2b becoming the active oxidant to conduct the cyclohexene epoxidation. In contrast to 2a, 1a does not disproportionate under the present reaction conditions. DFT calculations confirm that compound II models prefer C–H bond hydroxylation and that disproportionation of compound II models is controlled thermodynamically by the porphyrin ligands. Other aspects, such as acid and base effects on the disproportionation of compound II models, have been discussed as well.
With grid modernization efforts, future distribution networks, which consist of various distributed generators and flexible loads, will be more flexible and active. All new network components of distributed energy resources (DERs) drive and enable the transition towards a market-based distribution net-work that seeks the optimal allocation of all DERs. To address challenges associated with DERs, one promising solution is to utilize demand-side flexibility of building loads facilitated by demand response (DR) programs and provide ancillary grid services through distribution-level markets. Under this new paradigm, this paper proposes an efficient DR management strategy incorporating emerging price signals of distribution markets, i.e., distribution locational marginal price (DLMP), based on a hierarchical transactive control approach. The proposed approach establishes a two-layer decision-making framework; the upper layer formulates a bilevel model to obtain an optimal demand response (ODR) under DLMP, and the lower layer employs model-free control to dispatch the (aggregated) ODR to individual end users. Numerical case studies using a modified IEEE 33 test network are performed to verify the effectiveness of the proposed approach; load shifting and peak shaving for the distribution system operator and payments’ reduction for end users while maintaining their comfort.
This article proposes a fast predictive control method and a small DC-link inductor to minimize the DC-link current in current-source converter (CSC)-based solid-state transformer. The DC-link current minimization can significantly reduce power loss and improve efficiency. The challenge of this problem is on improving both steady-state and dynamic performance. PI control methods and large DC-link inductors are conventionally used in the CSC but have limited dynamic performance. A model predictive control (MPC) method is proposed to achieve switching-cycle-level settling time, and the DC-link inductor is sized for 40% ripple to enable fast current change. Importantly, this article also proposes to minimize the DC-link current by varying the current even within a line cycle under single-phase load to improve the steady-state performance, in contrast with the reduction to a constant value in the literature. The proposed MPC features a constant switching frequency without weighting factors. The MPC does not have a high computational burden and is implemented in a regular digital controller for a prototype of soft-switching solid-state transformer (S4T) with reduced conduction loss. The effectiveness of the proposed method has been experimentally verified on the SiC S4T prototype during steady-state and dynamics under different multiport power flow conditions up to 2 kV peak. Here, the DC-link current in the experiments is close to the minimum current with a short zero-vector duration, which further verifies the performance of the proposed method.
The primary objective of the proposed project is to evaluate the capabilities of Advanced Metering Infrastructure (AMI) based controls for grid operations. This includes monitoring and control at the secondary transformer level using existing AMI infrastructure. In addition, some of the challenges of using a model-less control will also be identified. The lessons learned will be disseminated to other utilities around the country through peer-reviewed publications with the consent of SDG&E. The scope of the work includes using data from SDG&E's existing AMI infrastructure and working with third party vendors selected by SDG&E. The grid edge monitoring systems and controls provided by the selected vendors will perform grid operations using AMI data. The National Renewable Energy Laboratory (NREL) will perform a software and controller-based evaluation of the grid edge controller, intelligent devices and sensors, at the Energy System Integration Facility (ESIF) laboratory.
Over the last several years, the United States (U.S.) Department of Energy (DOE) has sponsored human factors research and development (R and D) and human factors engineering (HFE) activities through its Light Water Reactor Sustainability (LWRS) program to modernize the main control rooms (MCR) of commercial nuclear power plants (NPP). Idaho National Laboratory (INL), in partnership with numerous commercial nuclear utilities, has conducted some of this R and D to enable the life extension of NPPs (i.e., provide the technical basis for the long-term reliability, productivity, safety, and security of U.S. NPPs). From these activities performed to date, a human factors meta model for U.S. NPP control room modernization can now be formulated. This paper discusses this emergent HFE meta model for NPP control room modernization, with the goal of providing an integrated high-level road map and guidance on how to perform human factors R and D and HFE for those in the U.S. nuclear industry engaged in the process of upgrading their MCRs. (authors)
Renewables and especially photovoltaics (PV) have benefitted significantly from a host of incentives and policies targeted toward enhanced integration and adoption of specific energy technologies. However, with the push to move forward into a subsidy-free market framework, behind-the-meter residential PV applications have generally struggled to retain their value (unlike utility scale and commercial projects) [1]. This project focused on developing control-theoretic solutions aimed at improving the integration and interaction of behind-the-meter residential PV with other distribution system assets (controllable and non-controllable) to enhance the integrated value of residential PV. To this end, a suite of decentralized control methodologies have been developed to enable effective coordination and control of behind-the-meter residential load customers’ PV, battery storage systems (BSS), controllable loads and other similar assets within a distribution feeder. This interaction aims at procuring energy savings and, thus, energy bill savings. The main source of savings is drawn from reducing the effect of demand charge pricing and is realized at the feeder level, assuming community level interaction and management among the aforementioned assets. Optimal control of the assets is implemented with a distributed optimization methodology, leveraging consensus-based algorithms. The results gathered from the optimal control simulations demonstrates that the savings can be duly achieved and the algorithm decision times (to dynamically control asset set points, for example) are fast. As for the overall efficiency of PV+BSS systems, to procure energy savings from curtailment of the demand charge pricing effects, the optimal control is set up so as to minimize the variance of the load for all customers, throughout a feeder and throughout time in a rolling horizon scheduling with model predictive control. The control takes into account inter-temporal electrochemical storage (battery) degradation costs: specifically, we have developed a long-term lifetime model for the BSS that weighs in the effect of the degradation factor in the dispatch formulations, thus, a considerable operating cost that affects energy decision making. The levelized cost of energy (LCOE – redefined for the purpose of quantifying asset integration effectiveness through the customers’ energy cost) is shown to be below the threshold set for the combined PV+BSS topology of $ 0.14/kWh for multiple cases of PV penetration all the way up to 50%, provided that a policy of shared ownership of and savings is in place. Further, the LCOE calculated for the case before the deployment PV+BSS systems is also achievable, i.e. the deployment of PV+BSS, if planned and scheduled optimally. will have no effect on customers’ energy costs. From the control methodology viewpoint, the developed consensus-based algorithms are shown to converge for a wide range of problem cases (spanning normal operating scenarios and contingencies), guaranteeing dispatch solutions under forecasting errors, communication break-downs and cyber-security attacks. The proposed control solutions are scalable and real-time implementable, with dispatch computations and device set-point updates converging in less than 2s in most practical instances of the above events.
Systems and methods for modeling and forecasting cyclical demand systems in the presence of dynamic control or dynamic incentives. A method for modeling a cyclical demand system comprises obtaining historical data on one or more demand measurements over a plurality of demand cycles, obtaining historical data on incentive signals over the plurality of demand cycles, constructing a model using the obtained historical data on the one or more demand measurements and the incentive signals, wherein constructing the model comprises specifying a state-space model, specifying variance parameters in the model, and estimating unknown variance parameters.
Connected intelligent vehicle following can improve safety and efficiency compared to today's road transport, but real traffic in the near future will not provide an ideal setting for its deployment. Unconnected human-driven vehicles will follow variable behavior patterns that combine with differences in dynamic capability to create heterogeneous scenarios. In this paper, connected automated vehicles employ model predictive control for following in traffic that may include both heavy and passenger vehicles at quasi-random positions. Adding further realism, some quasi-randomly mixed vehicles are completely unconnected and equipped with the reactive intelligent driver model using pseudorandom parameters. A mixed-integer quadratic programming formulation adapts the predictive algorithm to diverse powertrain operating point constraints. The preceding vehicle's control input is estimated from velocity and brake light observations and used to probabilistically generate a preview for the ego vehicle. Here, a terminal constraint designed using particle kinematics prevents collisions due to shortsightedness. Results are simulated at various heavy and predictive vehicle concentrations in the presence of packet loss. Linear fuel economy improvements between 1.4% and 1.9% per 10% increase in predictive vehicle penetration rate are shown.
Cooperative adaptive cruise control (CACC) can effectively reduce energy consumption, alleviate traffic congestion, and enhance safety. However, communication-related constraints and uncooperative vehicle users can disrupt CACC during real-world operations, significantly undermining the putative benefits of CACC. To alleviate the negative impacts of disrupted CACC, this study develops the trajectory shaper (TS) methods as backup solutions for two scenarios: (i) communication between vehicles is infeasible, and vehicles execute adaptive cruise control (ACC) using local sensor measurements; (ii) follower vehicles reject forming a cooperative platoon and execute their local distributed controllers using the information attained via communication. When communication is infeasible, a distributed TS is devised on each vehicle to modify the sensor measurements, enabling safe and efficient ACC operations. When communication is available but uncooperative agents are involved, the lead vehicle of the platoon executes a centralized TS to modify the information shared with uncooperative agents, achieving optimal platoon-level performance. The centralized and distributed TSs are implemented based on the model predictive control algorithms to yield optimal modifications on input information. Robustness is also factored to tackle model uncertainties during TS operations to ensure safety and efficiency. Numerical experiments validate the control performance of the proposed TSs.
The development of models that accurately relate the properties of a glass melt to its temperature and composition is important for glass formulation, melter control, and modeling the melt flow, refractory corrosion, and production rate. Using a database consisting of more than 4,000 data points measured between 900 °C and 1250 °C for over 600 unique low-activity waste glass compositions, we developed models for the melt viscosity and electrical conductivity. Models based on the Gaussian process regression approach outperformed models based on the Vogel–Fulcher–Tammann equation according to four standard metrics and yielded reliable prediction intervals. The models found primarily linear effects between properties and individual components, except for the effect of the Na 2 O mass fraction on the electrical conductivity. The effects were found to be consistent with current theories on physical processes involved with those properties.