Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Performance Storage Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Storage Futures Study - Distributed Solar and Storage Outlook: Methodology and Scenarios

This presentation discusses the fourth report in NREL’s Storage Futures Study (SFS) publications. The SFS is a multiyear research project that explores the role and impact of energy storage in the evolution and operation of the U.S. power sector. The SFS is designed to examine the potential impact of energy storage technology advancement on the deployment of utility-scale storage and the adoption of distributed storage, and the implications for future power system infrastructure investment and operations. This report describes the expanded capabilities of the Distributed Generation Market Demand (dGen) model to analyze the economics of distributed (behind-the-meter) PV paired with battery storage systems and presents projections of adoption for the contiguous United States out to 2050 under a range of scenarios. These scenarios use technology cost and performance assumptions consistent with the National Renewable Energy Laboratory’s 2020 Standard Scenarios paired with updated battery cost projections and existing policies. Additional scenarios evaluate sensitivities to the value of backup power and DER compensation mechanisms, collectively characterizing the future potential for behind-the-meter storage and identifying key drivers of adoption. Adoption projections of DER and battery storage at high spatial and temporal resolution, as presented in this report, can enable informed planning of technical infrastructure that can help planners capture the benefits and mitigate challenges to support the ongoing trend toward distributed electricity generation.

backup power↗

Storage-Intensive Supercomputing Benchmark Study

Critical data science applications requiring frequent access to storage perform poorly on today's computing architectures. This project addresses efficient computation of data-intensive problems in national security and basic science by exploring, advancing, and applying a new form of computing called storage-intensive supercomputing (SISC). Our goal is to enable applications that simply cannot run on current systems, and, for a broad range of data-intensive problems, to deliver an order of magnitude improvement in price/performance over today's data-intensive architectures. This technical report documents much of the work done under LDRD 07-ERD-063 Storage Intensive Supercomputing during the period 05/07-09/07. The following chapters describe: (1) a new file I/O monitoring tool iotrace developed to capture the dynamic I/O profiles of Linux processes; (2) an out-of-core graph benchmark for level-set expansion of scale-free graphs; (3) an entity extraction benchmark consisting of a pipeline of eight components; and (4) an image resampling benchmark drawn from the SWarp program in the LSST data processing pipeline. The performance of the graph and entity extraction benchmarks was measured in three different scenarios: data sets residing on the NFS file server and accessed over the network; data sets stored on local disk; and data sets stored on the Fusion I/O parallel NAND Flash array. The image resampling benchmark compared performance of software-only to GPU-accelerated. In addition to the work reported here, an additional text processing application was developed that used an FPGA to accelerate n-gram profiling for language classification. The n-gram application will be presented at SC07 at the High Performance Reconfigurable Computing Technologies and Applications Workshop. The graph and entity extraction benchmarks were run on a Supermicro server housing the NAND Flash 40GB parallel disk array, the Fusion-io. The Fusion system specs are as follows: SuperMicro X7DBE Xeon Dual Socket Blackford Server Motherboard; 2 Intel Xeon Dual-Core 2.66 GHz processors; 1 GB DDR2 PC2-5300 RAM (2 x 512); 80GB Hard Drive (Seagate SATA II Barracuda). The Fusion board is presently capable of 4X in a PCIe slot. The image resampling benchmark was run on a dual Xeon workstation with NVIDIA graphics card (see Chapter 5 for full specification). An XtremeData Opteron+FPGA was used for the language classification application. We observed that these benchmarks are not uniformly I/O intensive. The only benchmark that showed greater that 50% of the time in I/O was the graph algorithm when it accessed data files over NFS. When local disk was used, the graph benchmark spent at most 40% of its time in I/O. The other benchmarks were CPU dominated. The image resampling benchmark and language classification showed order of magnitude speedup over software by using co-processor technology to offload the CPU-intensive kernels. Our experiments to date suggest that emerging hardware technologies offer significant benefit to boosting the performance of data-intensive algorithms. Using GPU and FPGA co-processors, we were able to improve performance by more than an order of magnitude on the benchmark algorithms, eliminating the processor bottleneck of CPU-bound tasks. Experiments with a prototype solid state nonvolative memory available today show 10X better throughput on random reads than disk, with a 2X speedup on a graph processing benchmark when compared to the use of local SATA disk.

99 GENERAL AND MISCELLANEOUS↗

Techno-Economic Analysis of a Cryogenic Flux Capacitor for Grid Storage

Abstract The Cryogenic Flux Capacitor (CFC) is a cold, dense fluid storage core with integrated design features that afford the designer flexibility and provide new possibilities for the storage and discharge of energy. The stored energy, in this case, is represented by hydrogen physically bonded within the nanoscale pores within the aerogel composite blanket material, and the process of bonding or debonding is governed by principles of physical adsorption (physisorption) and thermodynamics. The large surface area afforded by the nanoporous aerogel (∼1,000 m2/g) allows for storage densities close to, or in some cases exceeding, that of normal boiling point liquids. Its performance easily exceeds what can be achieved via ambient temperature, high-pressure gas storage for an equivalent volume. CFC storage is predicted to be easily scalable, is constructed from readily available commercial materials, lends itself to a range of pressure applications, and is geometry insensitive. The high energy density of CFC-stored hydrogen allows long durations of storage, such as daily to monthly cycling, which corresponds to approximately 10 to 100 hours of duration, respectively. The techno-economic analysis examines different types of hydrogen storage for commercial viability. The assessment includes the use of hydrogen blended with natural gas in a combined cycle gas turbine. The study provides results for a range of blends from 100% natural gas to 100% hydrogen. The required fuel usages are estimated for the intended application in a grid scenario that features large amounts of renewable penetration, 10 hours, and as a baseload, 100 hours. The study presents preliminary estimates of the capital cost of storage and operating cost of storage. In addition, the cost of firing natural gas and capturing the carbon dioxide (CO2) in a carbon capture and sequestration (CCS) system is assessed. Based on the study, it is shown that CFC can competitively meet performance and cost needs for grid-based energy storage.

08 HYDROGEN↗

FARM supervisory capabilities for thermal energy storage

The FARM (Feasible Actuator Range Modifier) module is a component of the RAVEN-based FORCE framework for the analysis of Integrated Energy Systems (IES). FARM aids HERON in the solution of the power dispatch problem by evaluating feasible set-point signals to be issued to the control systems of the different IES unit components. Set-points need to satisfy limits on both production variables (i.e., the variables to be optimized such as the electrical power, etc.) and process variables tied to the service life of equipment (e.g., steam flowrate, vessel pressure, turbine firing temperature, etc.). To enforce all these limits, a two-stage approach is adopted. First, the power dispatcher algorithm in HERON module estimates set-points that meet the constraints on the production variables, e.g., power levels and power ramp rate limits. These constraints are called explicit constraints. Then, if necessary, FARM adjusts these set-points to ensure the respect of the limits on the process variables of interest, given the knowledge of the system dynamics acquired through machine learning algorithms. These constraints are called implicit constraints. From this standpoint, FARM constitutes a bridge between the HERON power dispatcher that adopts a simplified description of the IES unit (low-resolution physics) and the HYBRID high-fidelity models (high-resolution physics). In this report, an overview of the major capabilities of the latest release of FARM is provided, along with a summary of the tool demonstration campaign conducted at the Dynamic Energy Technology and Integration Laboratory (DETAIL) facility. These results assess the performance of the control system architecture embedding FARM both as a Validator of the HERON power dispatcher and as a real time Supervisory control scheme. Additionally, the report outlines the areas that FARM might benefit from, along with proposed solutions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An implementation analysis of the linear discontinuous finite element method

This paper provides an implementation analysis of the linear discontinuous finite element method (LD-FEM) that spans the space of (l, x, y, z). A practical implementation of LD includes 1) selecting a computationally efficient algorithm to solve the 4 x 4 matrix system Ax = b that describes the angular flux in a mesh element, and 2) choosing how to store the data used to construct the matrix A and the vector b to either reduce memory consumption or increase computational speed. To analyze the first of these, three algorithms were selected to solve the 4 x 4 matrix equation: Cramer's rule, a streamlined implementation of Gaussian elimination, and LAPACK's Gaussian elimination subroutine dgesv. The results indicate that Cramer's rule and the streamlined Gaussian elimination algorithm perform nearly equivalently and outperform LAPACK's implementation of Gaussian elimination by a factor of 2. To analyze the second implementation detail, three formulations of the discretized LD-FEM equations were provided for implementation in a transport solver: 1) a low-memory formulation, which relies heavily on 'on-the-fly' calculations and less on the storage of pre-computed data, 2) a high-memory formulation, which pre-computes much of the data used to construct A and b, and 3) a reduced-memory formulation, which lies between the low - and high-memory formulations. These three formulations were assessed in the Jaguar transport solver based on relative memory footprint and computational speed for increasing mesh size and quadrature order. The results indicated that the memory savings of the low-memory formulation were not sufficient to warrant its implementation. The high-memory formulation resulted in a significant speed advantage over the reduced-memory option (10-50%), but also resulted in a proportional increase in memory consumption (5-45%) for increasing quadrature order and mesh count; therefore, the practitioner should weigh the system memory constraints against any required runtime constraints to determine which option is more suitable for his or her specific applications. (authors)

97 MATHEMATICS AND COMPUTING↗

Symmetric Active/Active Metadata Service for High Availability Parallel File Systems

High availability data storage systems are critical for many applications as research and business become more data-driven. Since metadata management is essential to system availability, multiple metadata services are used to improve the availability of distributed storage systems. Past research focused on the active/standby model, where each active service has at least one redundant idle backup. However, interruption of service and even some loss of service state may occur during a fail-over depending on the used replication technique. In addition, the replication overhead for multiple metadata services can be very high. The research in this paper targets the symmetric active/active replication model, which uses multiple redundant service nodes running in virtual synchrony. In this model, service node failures do not cause a fail-over to a backup and there is no disruption of service or loss of service state. We further discuss a fast delivery protocol to reduce the latency of the needed total order broadcast. Our prototype implementation shows that metadata service high availability can be achieved with an acceptable performance trade-off using our symmetric active/active metadata service solution.

99 GENERAL AND MISCELLANEOUS↗

Bi-Level Arbitrage Potential Evaluation for Grid-Scale Energy Storage Considering Wind Power and LMP Smoothing Effect

Our paper deals with extended-term energy storage (ES) arbitrage problems to maximize the annual revenue in deregulated power systems with high penetration wind power. The conventional ES arbitrage model takes the locational marginal prices (LMP) as an input and is unable to account for the impacts of ES operations on system LMPs. This paper proposes a bi-level ES arbitrage model, where the upper level maximizes the ES arbitrage revenue and the lower level simulates the market clearing process considering wind power and ES. The bi-level model is formulated as a mathematical program with equilibrium constraints (MPEC) and then recast into a mixed-integer linear programming (MILP) using strong duality theory. Wind power fluctuations are characterized by the GARCH forecast model and the forecast error is modeled by forecast-bin based Beta distributions. Case studies are performed on a modified PJM 5-bus system and an IEEE 118-bus system with a weekly time horizon over an annual term to show the validity of the proposed bi-level model. The results from the conventional model and the bi-level model are compared under different ES power and energy ratings, and also various load and wind penetration levels.

17 WIND ENERGY↗

Performance of U 3 Si 2 in an LWR following a cladding breach during normal operation

High-density fuels have been proposed as a possible replacement for uranium-dioxide as a fuel for light water reactors (LWRs) due to their increased loading of fissionable material. The objectives of this proposal are (1) to increase reactor cycle length and reactor power, and (2) to offset any neutronic penalty associated with advanced cladding systems. Of the high-density fuels under consideration, there is particular interest in triuranium disilicide (U 3 Si 2 ) due to its increased metal density and favorable thermal properties as compared to UO 2 . However, there are concerns regarding the chemical compatibility of U 3 Si 2 with water and steam as used for LWR coolant.This paper summarizes research on fuel-coolant chemical compatibility for UO 2 LWR fuel during a cladding breach and highlights that generally, because of its chemical inertness, UO 2 -coolant reactions are of little consequence to reactor operation. However, the volumetric expansion associated with the reaction of UO 2 and oxygen is a concern for possible conditions encountered during air ingress of dry storage. These same concerns arise for U 3 Si 2 , which exhibits greater volumetric expansion than UO 2 when exposed to water or steam. These reactions ultimately result in increased fuel volume that the cladding must accommodate, as well as additional heat generated as the fuel reacts.The BISON fuel performance code was used to perform a comparative analysis on the behavior of UO 2 and U 3 Si 2 under normal operation. Silicide fuel simulations were then extended to demonstrate how varying thermodynamic and chemical kinetics influence fuel expansion and subsequent cladding performance during a cladding breach. These simulations were further extended to a 3D subsection of a fuel rod to demonstrate the characteristics of the resulting cladding crack.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ultrafast processing of pixel detector data with machine learning frameworks

Modern photon science performed at high repetition rate free-electron laser (FEL) facilities and beyond relies on 2D pixel detectors operating at increasing frequencies (towards 100 kHz at LCLS-II) and producing rapidly increasing amounts of data (towards TB/s). This data must be rapidly stored for offline analysis and summarized in real time for online feedback to the scientists. While at LCLS all raw data has been stored, at LCLS-II this would lead to a prohibitive cost; instead, enabling real time processing of pixel detector data (dark, gain, common mode, background, charge summing, subpixel position, photon counting, data summarization) allows reducing the size and cost of online processing, offline processing and storage by orders of magnitude while preserving full photon information. This could be achieved by taking advantage of the compressibility of sparse data typical for LCLS-II applications. Faced with a similar big data challenge a decade ago, computer vision stimulated revolutionary advances in machine learning hardware and software. We investigated if these developments are useful in the field of data processing for high speed pixel detectors and found that typical deep learning models and autoencoder architectures failed to yield useful noise reduction while preserving full photon information, presumably because of the very different statistics and feature sets in computer vision and radiation imaging. However, the raw performance of modern frameworks like Tensorflow inspired us to redesign in Tensorflow mathematically equivalent versions of the state-of-the-art, “classical” algorithms used at LCLS. The novel Tensorflow models resulted in elegant, compact and hardware agnostic code, gaining 1 to 2 orders of magnitude faster processing on an inexpensive consumer GPU, reducing by 3 orders of magnitude the projected cost of online analysis and compression without photon loss at LCLS-II. The novel Tensorflow models also enabled ongoing development of a pipelined hardware system expected to yield an additional 3 to 4 orders of magnitude speedup, necessary for meeting the data acquisition and storage requirements at LCLS-II, potentially enabling acquiring every single FEL pulse at full speed. Computer vision a decade ago was dominated by hand-crafted filters; their structure inspired the deep learning revolution resulting in modern deep convolutional networks; similarly, our novel Tensorflow filters provide inspiration for designing future deep learning models for ultrafast and efficient processing and classification of pixel detector images at FEL facilities.

47 OTHER INSTRUMENTATION↗

Case Study: NREL Campus Chilled Water Storage Potential: Benchmark Datasets Development and Applications, Task 4 - Use Case Demonstration

The Benchmark Datasets Development and Applications project is a three-year collaboration between the National Renewable Energy Laboratory (NREL), Oak Ridge National Laboratory, Pacific Northwest National Laboratory, and Lawrence Berkeley National Laboratory. The project seeks to collect and curate high-resolution, well-calibrated time series of building operational and indoor/outdoor environmental data, which are crucial to understanding and optimizing building energy efficiency performance and demand flexibility capabilities as well as benchmarking energy algorithms. Project outcomes include approximately twelve high-fidelity building datasets, enhanced data representation tools, and four case studies to illustrate example applications. The goal of these case studies is to define and execute analyses that demonstrate how one or more datasets collected through this project can address a data gap or challenge historically faced by building stakeholders. This technical paper summarizes the findings of one of these case studies, in which we studied the operational efficiencies of the central cooling system at NREL. We looked at three years of data from the three chillers in the Field Test Laboratory Building (FTLB), from 2019 to 2021, to compare equipment operation and demand throughout the time period. Our analysis indicates that all three chillers are operating at or below the optimal loading conditions for most of the operation time, and thus there was no efficiency drop due to loading of the chillers at full capacity. Our recommendation is that no chiller capacity increase is needed; instead, the central plant could benefit from adopting advanced control logics for optimal sequencing of chillers during part load operations. Analysis of adding chilled water thermal storage to the central plant indicated 34% savings in demand cost and 24.5% savings in total cost (energy consumption and demand charge cost). The payback period is estimated to be 11-22 years with an assumed TES cost of $\$$100-$200 per ton. This case study shows how a selected dataset is used to solve a practical building problem - learning the operational status of its components, analyzing the effectiveness of a proposed new technique, and aiding decision-making for the building operations and maintenance team.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Polyanion-type iron-based sulfate cathode materials: From fundamental research to industrialization

Sodium-ion batteries (SIBs) with the merits of abundant sodium resources and low cost are considered significant supplements to lithium-ion batteries in large-scale energy storage systems. Among the discovered cathode materials for SIBs, iron-based sulfate materials have attracted widespread attention due to their high operating voltage, superior structural stability, and high safety. Here, in this review, we summarize the research achievements of iron-based sulfate cathode materials in fundamental research, as well as provide a comprehensive overview of its industrialization progress for the first time. Meanwhile, effective modification strategies (including morphology design, hybridization with carbon materials, and construction of heterostructure) and further research directions to boost the sodium storage performance of iron-based sulfate cathode materials are also proposed. This review can provide valuable guidance for developing high-performance iron-based sulfate cathode materials for practical application.

cathode materials↗

Demonstration of a modeling toolkit for the design of building electrical distribution systems

The deployment of building equipment (e.g., lighting, security) and miscellaneous electrical loads that fundamentally require DC power for operation is increasing. Powering these DC loads has traditionally required an AC/DC converter, but the installation of photovoltaic (PV) and battery energy storage systems that primarily produce DC power eliminates the need for AC/DC converters at each end-device. However, analyzing system energy efficiency and cost for different electrical distribution architectures can be challenging as software tools that support this are not readily available. This paper presents preliminary results from a laboratory verification of the Building Electrical Efficiency Analysis Model (BEEAM) toolkit that was developed to address this gap. Three different eight-luminaire lighting systems comprised of market-available products were designed and modeled: one that used traditional AC distribution, a second that used a hybrid AC -to- centralized DC electrical distribution architecture, and a third that used a hybrid AC -to- distributed DC architecture. Notably, AC/DC conversions are required in all three systems. BEEAM models for LED drivers as well as Power-over-Ethernet (PoE) switches were created using laboratory characterization data. The lighting systems were simulated in Modelica, and the results were compared with each other and physics-based expectations. Simulation results show that PoE system energy efficiency is highly dependent on both device specification (e.g., LED driver and PoE switch efficiency) and system architecture (e.g., PoE switch loading) choices, as expected. For the products and system architectures selected for this study, the two DC systems were found to be less efficient than the AC system over the course of typical operation. In future work, simulation results will be compared with laboratory measurements to validate the usefulness of this software for design, and lighting systems with integrated PV and battery energy storage will be simulated to quantify the energy performance improvements that result from the elimination of some AC/DC converters.

Waghale, Anay S.↗

Needs and Opportunities for Testing of Hydropower Technology Innovations

Despite hydropower’s status as a well-established technology, changes in the global energy sector have prompted a variety of necessary hydropower technological innovations. Examples include efficient lowhead turbines, more flexible and dispatchable hydropower and pumped storage systems to complement variable and intermittent renewable resources, and technologies providing higher environmental performance. However, while innovative technologies are currently being proposed to meet these development challenges, small hydropower facility owners do not have sufficient risk-bearing capacity to adopt new, unvalidated technologies. This discourages manufacturers from bringing nascent technologies to market and stalls the technological growth of the sector. To reduce the risks associated with new technologies and promote further innovation, systemic (and sometimes unconventional) validation activities and new testing capabilities for hydropower are highly desired. These testing capabilities must demonstrate the safety, environmental acceptability, reliability, and performance of innovative technologies to quantify their value compared with existing technologies. Establishing these capabilities through dedicated testing facilities will be key to promoting hydropower growth in the United States. Following direction from the House Energy and Water Development Committee, the US Department of Energy’s Water Power Technologies Office (WPTO) has been tasked with understanding the state of hydropower testing in the United States. This scoping report discusses the needs and opportunities of hydropower testing in the United States, with a specific focus on small hydropower. Future developments will likely mostly target low-head sites with less than 30 ft (9.1 m) from new stream-reach developments, non-powered dam retrofits, and rehabilitation/upgrade of existing plants.

13 HYDRO ENERGY↗

Insights into Methodologies and Stochastic Optimization of Thermal Energy Storage-Coupled Advanced Reactor Systems: A Comparison of Methods for Accessing Long-Term Sub-System Sizing Adequacy

This paper investigates the potential of coupling Thermal Energy Storage (TES) with Advanced Reactors (ARs) to address uncertainties posed by climate change in deep decarbonized power systems. The TES Use-case Team at Idaho National Laboratory (INL) has examined the potential of storing thermal energy from ARs during low demand periods and optimizing discharge during peak-priced hours, in both steady-state and transient conditions. Building on this groundwork, this study bridges the gaps in optimal sizing of the sub-system of TES-coupled AR systems using Risk Analysis Virtual Environment (RAVEN) and Holistic Energy Resource Optimization Network (HERON), INL?s framework for grid optimization. By applying this framework, we present statistically-robust optimal charge, discharge including balance of plant (BOP), and storage sizing for the High-Temperature Gas-Cooled Reactor (HTGR) with 203 MWth output. To this end, we generated synthetic price samples for 30 years using 2018 ? 2021 real-time market data from ERCOT, PJM and MISO. Our results reveals that the TES-coupled HTGR system is highly effective in maximizing revenue from electricity sales. We observed a substantial increase of 40 % in ERCOT and a noteworthy 15 % increase in PJM and MISO when compared to the conventional BOP without TES. This improvement is achieved through regionally-tailored sub-system sizing, which ranges from 398 to 416 MWth for the discharge system and 610 to 1029 MWth for the TES. We find that the average electricity price directly impacts the overall economics, while price volatility influences storage size. Additional sensitivity analyses were performed to access the impact of key assumptions on system economics and sizing, differentiating the optimization window (i.e., 24 ? 219 hours of chronological observations) and by imposing storage continuity condition in tracking TES cycles. We observed that at the 120-hour of the optimization window, a reasonable balance between computation time and accuracy was achieved. Our analysis also highlights the significance of conducting multi-day cycle analysis (> 120-hour) for TES to capture interaction between electricity prices and storage dynamics, providing a comprehensive understanding of TES behavior that AR developers should integrate into their plant designs.

25 ENERGY STORAGE↗

Safer Batteries through Coupled Multiscale Modeling (ICCS 2015)

Batteries are highly complex electrochemical systems, with performance and safety governed by coupled nonlinear electrochemical-electrical-thermal-mechanical processes over a range of spatiotemporal scales. We describe a new, open source computational environment for battery simulation known as VIBE - the Virtual Integrated Battery Environment. VIBE includes homogenized and pseudo-2D electrochemistry models such as those by Newman-Tiedemann-Gu (NTG) and Doyle- Fuller-Newman (DFN, a.k.a. DualFoil) as well as a new advanced capability known as AMPERES (Advanced MultiPhysics for Electrochemical and Renewable Energy Storage). AMPERES provides a 3D model for electrochemistry and full coupling with 3D electrical and thermal models on the same grid. VIBE/AMPERES has been used to create three-dimensional battery cell and pack models that explicitly simulate all the battery components (current collectors, electrodes, and separator). The models are used to predict battery performance under normal operations and to study thermal and mechanical response under adverse conditions.

battery safety↗

PCM Selection for Heat Pump Integrated with Thermal Energy Storage for Demand Response in Residential Buildings

Phase Change Materials (PCM) based Thermal energy storage (TES) is a widespread solution to shift buildings’ peak energy demand and add stability to the grid. PCMs can be used for space heating and cooling applications in residential buildings by integrating into the heat pump equipment or building envelope via several possible configurations. The heat pump integrated active PCM storage can provide significant energy savings and reduce peak demand, but the benefits vary substantially depending on the system configuration, storage capacity, and the temperature range of the PCM used. It is critical to provide a review of the materials and their suitability in heat pump integrated PCM systems. This paper will present an analysis of the PCM material selection for heat pump integrated TES in various configurations. The comprehensive review will compare the phase change materials with different melting temperatures, and configurations, corresponding to the energy savings and demand impact reported in the literature. This work is significant to guide the design of high-performance heat pump integrated PCM systems.

Sultan, Sara↗

Energy Storage Data Reporting in Perspective—Guidelines for Interpreting the Performance of Electrochemical Energy Storage Systems

Due to the tremendous importance of electrochemical energy storage, numerous new materials and electrode architectures for batteries and supercapacitors have emerged in recent years. Correctly characterizing these systems requires considerable time, effort, and experience to ensure proper metrics are reported. Many new nanomaterials show electrochemical behavior somewhere in between conventional double-layer capacitor and battery electrode materials, making their characterization a non-straightforward task. It is understandable that some researchers may be misinformed about how to rigorously characterize their materials and devices, which can result in inflation of their reported data. Additionally, this is not uncommon considering the current state of the field nearly requires record breaking performance for publication in high-impact journals. Incorrect characterization and data reporting misleads both the materials and device development communities, and it is the shared responsibility of the community to follow rigorous reporting methodologies to ensure published results are reliable to ensure constructive progress. This tutorial aims to clarify the main causes of inaccurate data reporting and to give examples of how researchers should proceed. The best practices for measuring and reporting metrics such as capacitance, capacity, coulombic and energy efficiencies, electrochemical impedance, and the energy and power densities of capacitive and pseudocapacitive materials are discussed.

25 ENERGY STORAGE↗

Containment Analysis Capability of UNF-ST&DARDS

The Used Nuclear Fuel-Storage, Transportation & Disposal Analysis Resource and Data System (UNF-ST&DARDS) methodology to perform automated containment analyses for potential transportation packages based on canister loading map information is described in this paper, and its capability is illustrated with example results. The allowable leakage rate is calculated with the procedures provided in ANSI N14.5-2014 and NUREG/CR-6487, which were adapted for containment analysis of a transportation package containing fuel assemblies with different nuclear characteristics (e.g., initial enrichment, burnup, and cooling time) and clad integrity (intact or damaged). UNF-ST&DARDS applies different source term calculation methodologies for low-burnup fuel (LBF) (i.e., <45 GWd/tonne U) assemblies and high-burnup fuel (HBF) (i.e., ≥45 GWd/tonne U) assemblies. The LBF radionuclide activities are based on actual fuel assembly burnup, initial enrichment, and cooling time. Bounding radionuclide activities based on a fuel pellet burnup value of 65 GWd/tonne U and actual fuel assembly cooling time are used for HBF assemblies. The fraction of failed fuel rods and the release fractions for the contributors to releasable source terms recommended in NUREG-1617 are used in the containment analysis regardless of fuel assembly burnup. However, UNF-ST&DARDS supports different parameter values for LBF and HBF assemblies. Finally, the containment analysis methodology for as-loaded transportation packages is presented in detail, and the UNF-ST&DARDS containment analysis capability is illustrated with results for simulated transportation packages containing spent nuclear fuel canisters in dry storage at selected sites.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗