Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Kodak AMSD Mirror Development Program

The Advanced Mirror System Demonstration Program is developing minor technology for the next generation optical systems. Many of these systems will require extremely lightweight and stable optics due to the overall size of the primary mirror. These segmented, deployable systems require new technology that AMSD is developing. The on-going AMSD program is a critical enabler for Next Generation Space Telescope (NGST) which will start in 2002. The status of Kodak's AMSD mirror and future plans will be discussed with respect to the NGST program.

Matthews, Gary↗

Application of Bacteriorhodopsin Films in an Adaptive-Focusing Schlieren System

The photochromic property of bacteriorhodopsin films is exploited in the application of a focusing schlieren optical system for the visualization of optical phase information. By encoding an image on the film with light of one wavelength and reading out with a different wavelength, the readout beam can effectively see the photographic negative of the original image. The potential advantage of this system over previous focusing schlieren systems is that the updatable nature of the bacteriorhodopsin film allows system adaptation. I discuss two image encoding and readout techniques for the bacteriorhodopsin and use film transmission characteristics to choose the more appropriate method. I demonstrate the system principle with experimental results using argon-ion and He-Cd lasers as the two light sources of different wavelengths, and I discuss current limitations to implementation with a white-light source.

Downie, John D.↗

Application of Bacteriorhodopsin Films in an Adaptive-Focusing Schlieren System

The photochromic property of bacteriorhodopsin films is exploited in the application of a focusing schlieren optical system for the visualization of optical phase information. By encoding an image on the film with light of one wavelength and reading out with a different wavelength, the readout beam can effectively see the photographic negative of the original image. The potential advantage of this system over previous focusing schlieren systems is that the updatable nature of the bacteriorhodopsin film allows system adaptation. I discuss two image encoding and readout techniques for the bacteriorhodopsin and use film transmission characteristics to choose the more appropriate method. I demonstrate the system principle with experimental results using argon-ion and He-Cd lasers as the two light sources of different wavelengths, and I discuss current limitations to implementation with a white-light source.

Downie, John D.↗

A frequency tunable, eight-channel correlation ECE system for electron temperature turbulence measurements on the DIII-D tokamak

A new eight-channel correlation electron cyclotron emission diagnostic has recently been installed on the DIII-D tokamak to study both turbulent and coherent electron temperature fluctuations under various plasma conditions and locations. This unique system is designed to cover a broad range of operation space on DIII-D (1.6-2.1 T, detection frequency: 72-108 GHz) via four remotely selected local oscillators (80, 88, 96, and 104 GHz). Eight radial locations are measured simultaneously in a single discharge covering as much as half the minor radius. In this paper, we present design details of the quasi-optical system, the receiver, as well as representative data illustrating operation of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser Calibration Experiment for Small Objects in Space

The Air Force Research Laboratory/Directed Energy Directorate (AFRL/DE) and NASA/Marshall Space Flight Center (MSFC) are looking at a series of joint laser space calibration experiments using the 12J 15Hz CO2 High Performance CO2 Ladar Surveillance Sensor (FU-CLASS) system on the 3.67 meter aperture Advanced Electro-Optics System (AEOS). The objectives of these experiments are to provide accurate range and signature measurements of calibration spheres, demonstrate high resolution tracking capability of small objects, and support NASA in technology development and tracking projects. Ancillary benefits include calibrating radar and optical sites, completing satellite conjunction analyses, supporting orbital perturbations analyses, and comparing radar and optical signatures. In the first experiment, a Global Positioning System (GPS)/laser beacon instrumented microsatellite about 25 cm in diameter will be deployed from a Space Shuttle Hitchhiker canister or other suitable launch means. Orbiting in low earth orbit, the microsatellite will pass over AEOS on the average of two times per 24-hour period. An onboard orbit propagator will activate the GPS unit and a visible laser beacon at the appropriate times. The HI-CLASS/AEOS system will detect the microsatellite as it rises above the horizon, using GPS-generated acquisition vectors. The visible laser beacon will be used to fine-tune the tracking parameters for continuous ladar data measurements throughout the pass. This operational approach should maximize visibility to the ground-based laser while allowing battery life to be conserved, thus extending the lifetime of the satellite. GPS data will be transmitted to the ground providing independent location information for the microsatellite down to sub-meter accuracies.

Campbell, Jonathan↗

Upgrade of the Resonance Ionization Mass Spectrometer for Precise Identification of Failed Fuel in a Fast Reactor

Isotopic analysis of krypton (Kr) and xenon (Xe) by resonance ionization mass spectrometry (RIMS) is an effective tool for identification of failed fuel in fast reactors to achieve their safety operation and high plant availability. Reliability of the failed fuel detection and location (FFDL) system depends on the precise determination of {sup 78}Kr/{sup 80}Kr, {sup 82}Kr/{sup 80}Kr and {sup 126}Xe/{sup 129}Xe isotopic ratios, which is mainly hampered by statistical errors for detection of the corresponding isotopes except {sup 82}Kr generated in large amounts during operation of fast reactors. In this paper, we report on improvements of the laser optical system of our spectrometer to increase the resonance ionization efficiency of Kr and Xe atoms, focusing on (i) utilization of the uniform YAG laser beam to improve the wavelength conversion efficiency of sum frequency generation and (ii) reflection of the ultraviolet light by a concave mirror to increase the photon density. The results indicate that our upgraded resonance ionization mass spectrometer has enough performance for isotopic analysis of Kr and Xe required in the Monju FFDL system.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Dynamic power and chirp measurements of amplified 19 ps pulses in traveling-wave and reflective semiconductor optical amplifiers using a linear pulse characterization technique

The dynamic chirp and power of amplified pulses in semiconductor optical amplifiers is of importance in the application of these devices as conventional amplifiers and in optical signal processing. Non-linear measurement techniques are appropriate for pulsewidths less than 5 ps but have low sensitivity for wider pulsewidths commonly present in moderate bit rate optical systems. Typical measurements of chirp and power of 20 GHz repetition rate amplified 19 ps pulsewidth pulses in traveling-wave and reflective SOAs are obtained using a linear characterization technique based on small-signal sinusoidal modulation at half the pulse stream repetition rate and post-processing of the resulting optical spectrums. The results show that the amplified pulse dynamic power and chirp can have a complex structure and thereby pulse spectrum, which in turn can influence pulse propagation in optical fiber.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Acoustic superradiance from optical vortices in self-defocusing cavities

In a self-defocusing optical cavity, optical-field perturbations on a vortex background behave as sound waves in a (2+1) rotating acoustic black-hole spacetime. Numerical integration of the associated Klein-Gordon equation using typical experimental parameters shows that optical perturbations in the appropriate frequency range are amplified through the mechanism of superradiance. These results suggest the possibility to observe this phenomenon in a common nonlinear optical system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-Performance Computer Modeling of the Cosmos-Iridium Collision

This paper describes the application of a new, integrated modeling and simulation framework, encompassing the space situational awareness (SSA) enterprise, to the recent Cosmos-Iridium collision. This framework is based on a flexible, scalable architecture to enable efficient simulation of the current SSA enterprise, and to accommodate future advancements in SSA systems. In particular, the code is designed to take advantage of massively parallel, high-performance computer systems available, for example, at Lawrence Livermore National Laboratory. We will describe the application of this framework to the recent collision of the Cosmos and Iridium satellites, including (1) detailed hydrodynamic modeling of the satellite collision and resulting debris generation, (2) orbital propagation of the simulated debris and analysis of the increased risk to other satellites (3) calculation of the radar and optical signatures of the simulated debris and modeling of debris detection with space surveillance radar and optical systems (4) determination of simulated debris orbits from modeled space surveillance observations and analysis of the resulting orbital accuracy, (5) comparison of these modeling and simulation results with Space Surveillance Network observations. We will also discuss the use of this integrated modeling and simulation framework to analyze the risks and consequences of future satellite collisions and to assess strategies for mitigating or avoiding future incidents, including the addition of new sensor systems, used in conjunction with the Space Surveillance Network, for improving space situational awareness.

42 ENGINEERING↗

The 25 mA continuous-wave surface-plasma source of H{sup −} ions

The ion source with the Penning geometry of electrodes producing continuous-wave beam of H{sup −} ions with current up to 25 mA was developed. Several improvements were introduced to increase source intensity, reliability, and lifetime. The collar around the emission aperture increases the electrons filtering. The apertures’ diameters of the ion-optical system electrodes were increased to generate the beam with higher intensity. An optimization of electrodes’ temperature was performed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gemini frontier fields: wide-field adaptive optics K{sub s}-band imaging of the galaxy clusters MACS J0416.1-2403 and ABELL 2744

We have observed two of the six Frontier Fields galaxy clusters, MACS J0416.1-2403 and Abell 2744, using the Gemini Multi-Conjugate Adaptive Optics System (GeMS) and the Gemini South Adaptive Optics Imager (GSAOI). With 0.″ 08–0.″ 10 FWHM our data are nearly diffraction-limited over a 100{sup ′′}×100{sup ′′} wide area. GeMS/GSAOI complements the Hubble Space Telescope (HST) redwards of 1.6 μm with twice the angular resolution. We reach a 5σ depth of K{sub s}∼25.6 mag (AB) for compact sources. In this paper, we describe the observations, data processing, and initial public data release. We provide fully calibrated, co-added images matching the native GSAOI pixel scale as well as the larger plate scales of the HST release, adding to the legacy value of the Frontier Fields. Our work demonstrates that even for fields at high galactic latitude where natural guide stars are rare, current multi-conjugated adaptive optics technology at 8 m telescopes has opened a new window on the distant universe. Observations of a third Frontier Field, Abell 370, are planned.

79 ASTRONOMY AND ASTROPHYSICS↗

Tunable intense Airy beams and tailored femtosecond laser filaments

Optical aberrations are usually considered a drawback in optical systems. Here we show that through them a net cubic phase modulation can be imprinted on the wave front of a light beam, which after spatial Fourier transformation creates Airy beams. Experiments and supporting simulations demonstrate that appropriately adjusted cylindrical lenses can produce both one- and two-dimensional tunable Airy beams. The use of simple optical elements makes the approach attractive and convenient for generating intense femtosecond Airy beams and filaments. Moreover, we show that the Airy tunability is an excellent means of obtaining tailored filaments in both size and intensity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

GeMS/GSAOI photometric and astrometric performance in dense stellar fields

Ground-based imagers at 8 m class telescopes assisted by multi-conjugate adaptive optics are primary facilities with which to obtain accurate photometry and proper motions in dense stellar fields. We observed the central region of the globular clusters Liller 1 and NGC 6624 with the Gemini Multi-conjugate Adaptive Optics System (GeMS) feeding the Gemini South Adaptive Optics Imager (GSAOI) currently available at the Gemini South telescope, under different observing conditions. We characterized the stellar point-spread function (PSF) in terms of FWHM, Strehl ratio (SR), and encircled energy (EE), over the field of view (FOV). We found that, for sub-arcsecond seeing at the observed airmass, we can obtain the diffraction-limited PSF (FWHM ≈80 mas), SR ∼ 40%, and EE ≥ 50% with a dispersion around 10% over the FOV of 85″ × 85″, in the K {sub s} band. In the J band the best images provide FWHMs between 60 and 80 mas, SR >10%, and EE>40%. For seeing at the observed airmass exceeding 1″, the performance worsens but it is still possible to perform PSF fitting photometry with 25% EE in J and 40% in K {sub s}. We also computed the geometric distortions of GeMS/GSAOI and we obtained corrected images with an astrometric accuracy of ∼1 mas in a stellar field with high crowding.

79 ASTRONOMY AND ASTROPHYSICS↗

High resolution imagery with the large space telescope.

A number of general characteristics of a diffraction limited telescope are examined, giving attention to the optical system of the Stratoscope II instrument. The optical resolution of a telescope can be described in at least three different ways, involving the wavefront error, the optical transfer function, and the point spread function. The Stratoscope II tolerance budget and the performance of the instrument are discussed together with a goal for the resolution of the large space telescope (LST) which is to be designed. The very high resolving power of the LST will be utilized in many ways. The imagery of extended objects with low surface contrast is considered along with the photometry of very faint stars.

Danielson, R. E.↗

Thrust vectoring systems

The design, fabrication, and testing of thrust vectorable ion optical systems capable of controlling the thrust direction from both 5- and 30-cm diameter ion thrusters is described. Both systems are capable of greater than 10 deg thrust deflection in any azimuthal direction. The 5-cm system is electrostatic and hence has a short response time and minimal power consumption. It has recently been tested for more than 7500 hours on an operational thruster. The 30-cm system is mechanical, has a response time of the order of 1 min, and consumes less than 0.3% of the total system input power at full deflection angle.

King, H. J.↗

Holographic optical elements: Fabrication and testing

The basic properties and use of holographic optical elements were investigated to design and construct wide-angle, Fourier-transform holographic optical systems for use in a Bragg-effect optical memory. The performance characteristics are described along with the construction of the holographic system.

Zech, R. G.↗

Electrophoresis experiment, experiment MA-014

A continuous, free flow electrophoresis study was conducted during the Apollo Soyuz Test Project mission to investigate and evaluate the increase in sample flow rate and sample resolution achievable in space. The electrophoresis equipment was designed for the separation of four mixtures of biological cells with variable sample flow rates, buffer flow rates, and electric field gradients. Separation quality was assessed by measuring the light from a quartz lamp through the electrophoresis channel and on to a photodiode system. The preliminary results indicate that all monitored systems operated correctly during the experiment. The optical system produced a light that was too bright to discern true cell distributions, but data were received that show a distribution of separated cells.

Hannig, K.↗