Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solar Integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

In situ recombination junction between p-Si and TiO 2 enables high-efficiency monolithic perovskite/Si tandem cells

Increasing the power conversion efficiency of silicon (Si) photovoltaics is a key enabler for continued reductions in the cost of solar electricity. Here, we describe a two-terminal perovskite/Si tandem design that increases the Si cell’s output in the simplest possible manner: by placing a perovskite cell directly on top of the Si bottom cell. The advantageous omission of a conventional interlayer eliminates both optical losses and processing steps and is enabled by the low contact resistivity attainable between n-type TiO 2 and Si, established here using atomic layer deposition. We fabricated proof-of-concept perovskite/Si tandems on both homojunction and passivating contact heterojunction Si cells to demonstrate the broad applicability of the interlayer-free concept. Stabilized efficiencies of 22.9 and 24.1% were obtained for the homojunction and passivating contact heterojunction tandems, respectively, which could be readily improved by reducing optical losses elsewhere in the device. This work highlights the potential of emerging perovskite photovoltaics to enable low-cost, high-efficiency tandem devices through straightforward integration with commercially relevant Si solar cells.

59 BASIC BIOLOGICAL SCIENCES↗

Walmart Experimental Store Performance Stories: Preprint

Walmart opened two experimental stores--one in Colorado and one in Texas--in 2005 to serve as test beds for several advanced building systems. Each embodied more than 50 experiments covering materials, water systems, energy systems, and renewable energy production. Walmart worked for three years with the National Renewable Energy Laboratory for the Colorado Store and Oak Ridge National Laboratoryfor the Texas store to monitor, analyze, and report on their performance. HVAC experiments included waste oil boilers, a microturbine/absorption chiller combined heat and power system, evaporative cooling, and a transpired solar collector. The refrigeration systems integrated a medium-temperature secondary loop, evaporatively cooled condenser, doors on medium-temperature cases, andlight-emitting diodes on cases. Experiments in the lighting systems included a redesigned roof for clerestory daylighting and T-5 fluorescent lamps. Three photovoltaic systems for a total of 135 kW and a 50-kW wind turbine are also included. The energy system performance was compared to the measured performance of a prototypical Walmart store and to other benchmarks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Adaptive Protection and Control for High Penetration PV and Grid Resilience (Final Technical Report)

The report summarizes the work and accomplishments of DOE SETO funded project 36533 “Adaptive Protection and Control for High Penetration PV and Grid Resilience”. In order to increase the amount of distributed solar power that can be integrated into the distribution system, new methods for optimal adaptive protection, artificial intelligence or machine learning based protection, and time domain traveling wave protection are developed and demonstrated in hardware-in-the-loop and a field demonstration.

14 SOLAR ENERGY↗

All-AC, building integrated photovoltaic system for mass deployment of residential photovoltaic systems

Solar Red is developing novel PV installation methods and system designs that lower costs dramatically and allow seamless integration into the structure of any sloped roof using existing construction tools and processes. The overall objective of this project is to address the greatest barriers to massive adoption of residential and small commercial rooftop solar – scalability of installation and total cost of ownership - by moving Solar Red’s snap-in/snap-out PV installation method from the pre-prototype design phase to the development and construction of a deployed prototype system.

14 SOLAR ENERGY↗

Solar mechanics thermal response capabilities.

In many applications, the thermal response of structures exposed to solar heat loads is of interest. Solar mechanics governing equations were developed and integrated with the Calore thermal response code via user subroutines to provide this computational simulation capability. Solar heat loads are estimated based on the latitude and day of the year. Vector algebra is used to determine the solar loading on each face of a finite element model based on its orientation relative to the sun as the earth rotates. Atmospheric attenuation is accounted for as the optical path length varies from sunrise to sunset. Both direct and diffuse components of solar flux are calculated. In addition, shadowing of structures by other structures can be accounted for. User subroutines were also developed to provide convective and radiative boundary conditions for the diurnal variations in air temperature and effective sky temperature. These temperature boundary conditions are based on available local weather data and depend on latitude and day of the year, consistent with the solar mechanics formulation. These user subroutines, coupled with the Calore three-dimensional thermal response code, provide a complete package for addressing complex thermal problems involving solar heating. The governing equations are documented in sufficient detail to facilitate implementation into other heat transfer codes. Suggestions for improvements to the approach are offered.

14 SOLAR ENERGY↗

PERFORMANCE EVALUATION OF A SUSTAINABLE AND ENERGY EFFICIENT RE-ROOFING TECHNOLOGY USING FIELD-TEST DATA

Three test attics were constructed to evaluate a new sustainable method of re-roofing utilizing photo-voltaic (PV) laminates, metal roofing panels, and PCM heat sink in the Envelope Systems Research Apparatus (ESRA) facility in the ORNL campus. Figure 1 is a picture of the three attic roofs located adjacent to each other. The leftmost roof is the conventional shingle roof, followed by the metal panel roof incorporating the cool-roof coating, and third from left is the roof with the PCM. On the PCM roof, the PV panels are seen as well; they're labelled from left-to-right as panels 5, 6 and 7. The metal panel roof consists of three metal panels with the cool-roof coating; in further discussion this is referred to as the infrared reflective (IRR) metal roof. The IRR metal panels reflect the incoming solar radiation and then quickly re-emit the remaining absorbed portion, thereby reducing the solar heat gain of the attic. Surface reflectance of the panels were measured using a Solar Spectrum Reflectometer. In the 0.35-2.0 {mu}m wavelength interval, which accounts for more than 94% of the solar energy, the IRR panels have an average reflectance of 0.303. In the infrared portion of the spectrum, the IRR panel reflectance is 0.633. The PCM roof consists of a layer of macro-encapsulated bio-based PCM at the bottom, followed by a 2-cm thick layer of dense fiberglass insulation with a reflective surface on top, and metal panels with pre-installed PV laminates on top. The PCM has a melting point of 29 C (84.2 F) and total enthalpy between 180 and 190 J/g. The PCM was macro-packaged in between two layers of heavy-duty plastic foil forming arrays of PCM cells. Two air cavities, between PCM cells and above the fiberglass insulation, helped the over-the-deck natural air ventilation. It is anticipated that during summer, this extra ventilation will help in reducing the attic-generated cooling loads. The extra ventilation, in conjunction with the PCM heat sink, are used to minimize thermal stresses due to the PV laminates on sunny days. In PV laminates sunlight is converted into electricity and heat simultaneous. In case of building integrated applications, a relatively high solar absorption of amorphous silicon laminates can be utilized during the winter for solar heating purposes with PCM providing necessary heat storage capacity. However, PV laminates may also generate increased building cooling loads during the summer months. Therefore, in this project, the PCM heat sink was to minimize summer heat gains as well. The PCM-fibreglass-PV assembly and the IRR metal panels are capable of being installed directly on top of existing shingle roofs during re-roofing, precluding the need for recycling or disposal of waste materials. The PV laminates installed on the PCM attic are PVL-144 models from Uni-Solar. Each laminate contains 22 triple junction amorphous silicon solar cells connected in series. The silicon cells are of dimensions 356 mm x 239 mm (14-in. x 9.4-in.). The PVL-144 laminate is encapsulated in durable ETFE (poly-ethylene-co-tetrafluoroethylene) high light-transmissive polymer. Table 1 lists the power, voltage and current ratings of the PVL-144 panel.

14 SOLAR ENERGY↗

Proceedings of the 21st Project Integration Meeting

Progress made by the Flat Plate Solar Array Project during the period April 1982 to January 1983 is described. Reports on polysilicon refining, thin film solar cell and module technology development, central station electric utility activities, silicon sheet growth and characteristics, advanced photovoltaic materials, cell and processes research, module technology, environmental isolation, engineering sciences, module performance and failure analysis and project analysis and integration are included.

Source record↗

Module-Integrated Power Converters Based on Universal Dock

Solar power installations using alternating current photovoltaic (ACPV) modules have significant cost and performance advantages over systems using conventional solar modules and string inverters. ACPV modules have improved energy harvest due to module-level power point tracking and redundancy. More importantly, ACPV modules are easier and cheaper to install, lowering the total installed cost, indirect costs, and barriers to market entry. Furthermore, ACPV modules have communications and data logging capability, yielding module-level telemetry data that is useful in site diagnostics and other data applications. The products of these efforts were threefold. First, an advanced microinverter power topology was developed, modeled, simulated, and tested. Second, new microinverter enclosure concepts were developed and tested. Third, a new ACPV module prototype was constructed, combining the power topology and the enclosure concepts. SolarBridge filed for patents in each of these areas and is transitioning the project from a concept phase to full development.

14 SOLAR ENERGY↗

Best Practices Case Study: CDC Realty, Inc. - Centennial Terrace, Tucson, AZ

Case study on CDC Realty who achieved HERS 70 by putting ducts in a conditioned attic insulated along the roofline with netted cellulose, R-5 rigid insulated sheathing over R-19 wall cavity insulation, and deep overhangs and low-e windows to minimize solar heat gain. The 17 homes are solar-ready for solar water heating and five have integral collector storage hot water systems on the roof.

Building America↗

Effect of Inlet Air Humidity on Performance of Solar Hybrid Combined Cycle Power Plant

The hybridization of conventional power plants by integrating renewable energy technologies is gaining attention in the recent past. These hybrid power plants perform better than conventional power plants and also have less detrimental effects on environment. In the presented research work a solar central receiver is integrated with a conventional gas turbine power plant with a bottoming steam Rankine cycle. The effect of specific humidity of air entering the compressor is on the performance of the power plant is studied. The humidification of air can be done in two ways viz. heating-humidification and cooling-humidification. The performance of the power plant for the afore mentioned processes are compared and it is found that the efficiency of the plant improved by 1% through heating-humidification of air.

14 SOLAR ENERGY↗

A general circulation model study of the effects of faster rotation rate, enhanced CO2 concentration, and reduced solar forcing: Implications for the faint young sun paradox

Solar energy at the top of the atmosphere (solar constant), rotation rate, and carbon dioxide (CO2) may have varied significantly over Earth's history, especially during the earliest times. The sensitivity of a general circulation model to faster rotation, enhanced CO2 concentration, and reduced solar constant is presented. The control simulation of this study has a solar constant reduced by 10% the present amount, zero land fraction using a swamp ocean surface, CO2 concentrations of 330 ppmv, present-day rotation rate, and is integrated under mean diurnal and seasonal solar forcing. Four sensitivity test are performed under zero land fraction and reduced solar constant conditions by varying the earth's rotation rate atmospheric CO2 concentration and solar constant. The global mean sea surface temperatures (SSTs) compared to the control simulation: were 6.6 K to 12 K higher than the control's global mean temperature of 264.7 K. Sea ice is confined to higher latitudes in each experiment compared to the control, with ice-free areas equatorward of the subtropics. The warm SSTs are associated with a 20% reduction in clouds for the rotation rate experiments and higher CO2 concentrations in the other experiments. These results are in contrast to previous studies that have used energy balance and radiative convective models. Previous studies required a much larger atmospheric CO2 increase to prevent an ice-covered Earth. The results of the study, suggest that because of its possible feedback with clouds, the general circulation of the atmosphere should be taken into account in understanding the climate of early Earth. While higher CO2 concentrations are likely in view of the results, very large atmospheric CO2 concentrations may not be necessary to counterbalance the lower solar constant that existed early in Earth's history.

Jenkins, Gregory S.↗

LOCALIZED STARBURSTS IN DWARF GALAXIES PRODUCED BY THE IMPACT OF LOW-METALLICITY COSMIC GAS CLOUDS

Models of galaxy formation predict that gas accretion from the cosmic web is a primary driver of star formation over cosmic history. Except in very dense environments where galaxy mergers are also important, model galaxies feed from cold streams of gas from the web that penetrate their dark matter halos. Although these predictions are unambiguous, the observational support has been indirect so far. Here, we report spectroscopic evidence for this process in extremely metal-poor galaxies (XMPs) of the local universe, taking the form of localized starbursts associated with gas having low metallicity. Detailed abundance analyses based on Gran Telescopio Canarias optical spectra of 10 XMPs show that the galaxy hosts have metallicities around 60% solar, on average, while the large star-forming regions that dominate their integrated light have low metallicities of some 6% solar. Because gas mixes azimuthally in a rotation timescale (a few hundred Myr), the observed metallicity inhomogeneities are only possible if the metal-poor gas fell onto the disk recently. We analyze several possibilities for the origin of the metal-poor gas, favoring the metal-poor gas infall predicted by numerical models. If this interpretation is correct, XMPs trace the cosmic web gas in their surroundings, making them probes to examine its properties.

79 ASTRONOMY AND ASTROPHYSICS↗

The mean magnetic field of the sun - Observations at Stanford

A solar telescope has been built to study the organization and evolution of large-scale solar magnetic fields and velocities. The observations are made using a Babcock-type magnetograph connected to a 22.9-m vertical Littrow spectrograph. Sun-as-a-star integrated-light measurements of the mean solar magnetic field have been made daily since May 1975. The typical mean-field magnitude has been about 0.15 G, with a typical measurement error of less than 0.05 G. The mean-field polarity pattern is essentially identical to the interplanetary-magnetic-field sector structure (seen near earth with a four-day lag). The differences in the observed structures can be understood in terms of a 'warped current sheet' model.

Scherrer, P. H.↗

Mapping the Solar Wind from its Source Region into the Outer Corona

The solar wind not only forms the space environment of Earth and other planets, but is also the cause of many phenomena observed in the Earth's atmosphere, such as aurorae. The expansion of the coronal plasma of the Sun is characteristic to many main sequence stars, and thus provides an example for understanding stellar winds as well. In spite of its importance for both space science and stellar physics, basic solar wind properties remain essentially unresolved. Since its discovery about 50 years ago, the complexity of the Sun corona - solar wind system has complicated the interpretation of observations. Recent progress in remote sensing observations as provided for example by YOHKOH, SOHO, SPARTAN and ULYSSES as well as some ground based techniques such as Interplanetary Scintillation observations, offer a compelling opportunity to unravel the 50 year old puzzle regarding the heat source or sources that cause the expansion of the solar corona. The new era of solar wind observations initiated by SOHO and ULYSSES, have also led to a wealth of new theoretical approaches. The goal of the proposed research was to carry out an integrated study of the coronal and solar wind plasma making use of the opportunities provided by the above spacecraft, as well as plasma emission calculations and new ideas on solar wind expansion theory.

Esser, Ruth↗

High temporal resolution generation expansion planning for the clean energy transition

As power systems integrate increasing quantities of wind, solar and energy storage resources, it is important to revisit power system capacity expansion modeling methods and assumptions that have been utilized in thermal- dominated systems. We conduct a series of case study analyses using a simplified representation of the Electric Reliability Council of Texas (ERCOT) system to demonstrate how least-cost capacity expansion outcomes are impacted by changes in model resolution across two temporal dimensions: 1) the number of considered representative periods, and 2) the system dispatch interval. First, we find that the least-cost generation portfolio can differ significantly for small changes in the number of representative days, but largely converges to the 365-day result once 104 representative days are considered. Furthermore, systems with wind, solar and storage resources were more sensitive to changes in the number of representative days than a thermal-dominated system. Second, we find that considering five-minute dispatch resolution consistently results in least-cost generation portfolios with less solar capacity and more energy storage capacity than corresponding scenarios with hourly dispatch intervals. This suggests that hourly dispatch representation fails to capture the intra-hour volatility of solar generation, and therefore also overlooks opportunities for storage resources to provide system value by balancing this volatility. Collectively these results indicate that capacity expansion modelers should revisit conventional approaches to temporal representation when conducting analyses of deeply decarbonized power systems to ensure that such analyses are robust and actionable. To our knowledge, this is the first study to analyze capacity expansion outcomes with five-minute dispatch resolution in this manner.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A High-Rate Lithium Manganese Oxide-Hydrogen Battery

Rechargeable hydrogen gas batteries show promises for the integration of renewable yet intermittent solar and wind electricity into the grid energy storage. Here, we describe a rechargeable, high-rate, and long-life hydrogen gas battery that exploits a nanostructured lithium manganese oxide cathode and a hydrogen gas anode in an aqueous electrolyte. The proposed lithium manganese oxide-hydrogen battery shows a discharge potential of ~1.3 V, a remarkable rate of 50 C with Coulombic efficiency of ~99.8%, and a robust cycle life. A systematic electrochemical study demonstrates the significance of the electrocatalytic hydrogen gas anode and reveals the charge storage mechanism of the lithium manganese oxide-hydrogen battery. This work provides opportunities for the development of new rechargeable hydrogen batteries for the future grid-scale energy storage.

25 ENERGY STORAGE↗

A hybrid encapsulation method for organic electronics

We report a thin-film encapsulation method for organic electronics that combines the deposition of a layer of SiO{sub x} or SiN{sub x} (100 nm) by plasma enhanced chemical vapor deposition followed by a layer of Al{sub 2}O{sub 3} (10-50 nm) by atomic layer deposition and a 1-{mu}m-thick layer of parylene by chemical vapor deposition. The effective water vapor transmission rates of the encapsulation was (2{+-}1)x10{sup -5} g/m{sup 2} day at 20 deg. C and 50% relative humidity (RH). The encapsulation was integrated with pentacene/C{sub 60} solar cells, which showed no decrease in conversion efficiency after 5800 h of exposure to air demonstrating the effectiveness of the encapsulation methodology.

36 MATERIALS SCIENCE↗