Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Development of a Testing Protocol for C7 Carbon Fiber Core Conductors

To avoid the high costs and environmental and regulatory challenges of building new lines to meet the power demand, utilities are searching for ways to increase power transmission capacity on existing lines and thereby. This could involve upgrading the network lines with conductors capable of transmitting greater capacity. In recent years, conductor manufacturers have begun producing new conductors that can operate at higher temperatures without violating present electrical clearances to ground and other objects. One new conductor technology is a carbon composite core with PPS polymer matrix and PEEK capping layer composite conductor, manufactured by Southwire Inc. The conductor uses new materials, which have not previously been used for overhead lines. The project made an initial characterization of the composite core to define the material used in the manufacture of the composite. Several analytical procedures were then conducted to evaluate the physical-chemical impacts on the composite as a result of thermal exposure. These procedures included thermogravimetry, dynamic mechanical analysis, thermal mechanical analyses, and optical microscopy. Mechanical three-point flexural tests, tensile tests, creep tests, and dynamic vibration tests were then performed to estimate the potential degradation after thermal aging. The report provides the basis to develop a qualification testing protocol for the carbon composite core at targeted service environments. The work covers the design of the qualification testing protocol and the follow-on validation testing to support the proposed methods. The research includes the following approaches: initial characterization, performance of thermal aging, characterization of the aged material, comparison of aged properties or characteristics to the original, and concluding by the findings through the developed qualification procedures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Interlaboratory Study of Digital Volume Correlation Error Due to X-Ray Computed Tomography Equipment and Scan Parameters: an Update from the DVC Challenge

Background: The quality of Digital Volume Correlation (DVC) full-field displacement measurements depends directly on the characteristics of the X-ray Computed Tomography (XCT) equipment, and scan procedures used to acquire the tomographic images. Objective: In this work, we seek to experimentally study the effects of XCT equipment and tomographic scan procedures on the quality of these images for DVC analysis, and to survey the level of DVC error that may be achieved using standard XCT operating procedures. Methods: Six participants in an interlaboratory study acquired high-quality XCT scans of a syntactic foam before and after rigid body motion. The resulting images were correlated using commercial DVC software to quantify error sources due to random image noise, reconstruction artifacts, as well as systematic spatial or temporal distortion. Results: In the absence of rigid body motion, the standard deviation of the displacement measurements ranged from 0.012 to 0.043 voxels using a moderate subvolume size, indicating that subvoxel measurement resolution could readily be achieved with a variety of XCT equipment and scan recipes. Comparison of consecutive scans without rigid body motion showed transient dilatational displacement gradients due to self-heating of the X-ray source and/or thermal expansion of the foam. Evaluation of the scans after rigid body motion showed significant, machine-specific spatial distortion in the displacement fields of up to 0.5 voxels; new approaches to remove this error need to be developed. Conclusions: Analysis of the scan protocols used in the interlaboratory study, as well as a complementary parametric sensitivity study, showed that the DVC error was strongly influenced by the XCT equipment, but could be mitigated by adjusting the total scan duration.

47 OTHER INSTRUMENTATION↗

Polybenzimidazole-derived carbon molecular sieve hollow fiber membranes with tailored oxygen selective transport

Polymer membrane carbonization is a promising strategy to obtain carbon molecular sieve (CMS) membrane materials with tailorable cavity size distributions for high gas selectivities beyond that attained from traditional polymer membrane materials. Despite their already demonstrated exceptional separation performance characteristics for several gas separation applications (e.g. CO 2 /CH 4 and H 2 /CO 2 ), further development of CMS membranes having high O 2 /N 2 perm-selectivity for energy-efficient high-purity O 2 production has proven challenging. Herein, we explore CMS hollow fiber membranes (HFMs) derived from highly rigid and tightly-packed polybenzimidazole (PBI) materials. Nearly defect-free PBI-derived CMS HFMs were fabricated and evaluated for O 2 /N 2 separation performance for the first time. The micro-structural and O 2 selective gas separation characteristics of PBI-CMS HFMs pyrolyzed at different pyrolysis conditions were intensively studied. With rigorous carbonization protocol optimization, we obtained highly O 2 permselective PBI-CMS HFMs having O 2 /N 2 selectivities approaching 14, enabling high purity O 2 production. The PBI-CMS HFM O 2 /N 2 separation performance dependence on operating conditions (e.g. temperature and feed pressure) are reported.

36 MATERIALS SCIENCE↗

Center for Alternate Synchronization and Timing (CAST) PTP Network Monitoring Report

The Oak Ridge National Laboratory Center for Alternative Synchronization and Timing (CAST) performs research, development, testing, and evaluation of alternative terrestrial-based timing and synchronization infrastructure for the US power grid and other critical infrastructures. Alternative timing options reduce reliance on GPS and enhance the overall resilience of critical infrastructures. CAST infrastructure uses Precision Time Protocol (PTP) as the primary conduit for delivery of synchronization packets. CAST deploys PTP over long terrestrial links to synchronize a multitude of remote boundary clocks and downstream power grid components with the authoritative grand master clocks. Network traffic issues can severely degrade PTP accuracy. This report focuses on examining network traffic anomalies and their effects on PTP operation as well as the potential implications to CAST’s high-precision remote synchronization operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Strategies for Enhancing Battery Life Under Fast Charging: Insights from NMC-Based Cell Cycling

Fast charging improves the usability of consumer electronics and electric vehicles (EVs) by reducing range anxiety and downtime but accelerates battery degradation and raises safety concerns. Optimizing operational conditions during fast-charging is critical to mitigating aging and ensuring safety. This study evaluated multilayer Gr/NMC811 cells under various conditions, including depths of discharge (DODs of 68%, 84%, and 100%), upper charge cutoff voltages (4.1–4.2 V), and post-charge rest periods (2–30 min), using a 20 min fast charging protocol for up to 500 cycles (up to 150,000 miles of EV use assuming 3.3 mi/kWh vehicle level energy efficiency). Surprisingly, higher DODs under fast charging improved battery life and performance compared to lower DODs. Reducing the upper charge cut-off voltage helped mitigate degradation. A brief 2 min rest period after charging further reduced aging effects. The primary aging modes were loss of lithium inventory and cathode active material. Although minor lithium plating was observed within 500 cycles, it did not affect performance significantly. These findings suggest that, with optimized conditions, cells can sustain hundreds of fast charge cycles—equivalent to over 100,000 miles of EV use—without significant adverse effects on performance or longevity.

25 - ENERGY STORAGE↗

Shuttle Orbiter medical system equipment/supplies evaluation

The effectivity was evaluated in zero gravity of several medical equipment and supply items flown in the Shuttle Orbiter Medical System (SOMS). Several procedures listed in Medical Operations Medical Checklist, JSC 1732 were also evaluated. Several items were drawn out of the kits and tested on the KC-135. In two different flights, the following elements were examined: (1) measuring IV flow (drip chamber, one way flow valve, and air/fluid separator); (2) chemstrip protocol for urine analysis in zero-gravity; and (3) tamper resistant seals for injectable medications.

Maidlow, Kristin↗

Acceptance Testing of a Satellite SCADA Photovoltaic-Diesel Hybrid System

Savannah State University (SSU) and the Florida Solar Energy Center (FSEC) have been participating in the NASA Advanced Communications Technology Satellite (ACTS) program for the last five years. This program was designed by NASA to help maintain U.S. leadership in commercial space communications by funding high-risk research, and to flight-test next-generation digital satellite components. Launched in 1993, ACTS is an U.S. government funded technology test-bed that incorporates high power Ka-band transponders, small spot beams, and on-board digital storage and switching technology. Associated with the spacecraft, is a prototype satellite control center that supports various application experiments. The SSU/FSEC application experiment is to developing a Photovoltaic-Diesel Hybrid Power system complete with satellite Supervisory Control and Data Acquisition (SCADA). The hybrid system was design to demonstrate the feasibility of using SCADA to maintain and operate remote village power systems. This configuration would enable experts at a central location to provide technical assistance to local technicians while they acquire a measure of proficiency with the hybrid system operation and maintenance. Upon full mastery of the technology, similar SCADA arrangement are planned to remotely monitor and control constellation of hybrid systems scattered overlarge rural areas. Two Orion Energy APEX-1000 hybrid systems were delivered in 1998, one was installed at SSU in eastern Georgia and the other was installed at FSEC in Central Florida. The project was designed to: (1) evaluate the performance of ACTS in a SCADA arrangement, (2) monitor the health and performance of all major hybrid subsystems, (3) investigate load control and battery charging strategies to maximize battery capacity and lifetime, and (4) develop satellite communication protocol. Preliminary results indicate that the hybrid design is suitable for satellite Supervisory Control and Data Acquisition. A modification to the controller software has produced a robust communication link capable of real time control and long term data collection.

Kalu, Alex↗

Real-Sim Interface: Enabling Multi-resolution Simulation and X-in-the-Loop Development for Connected and Automated Vehicles

We report connected and automated vehicles (CAVs) can bring safety, mobility, and energy benefits to transportation systems. Ideally, CAV applications would be fully evaluated and validated prior to real-world implementation. However, many technical challenges in both software and hardware hinder the process. To comprehensively evaluate all aspects of CAV applications, an integrated evaluation environment is needed with various simulation tools from different domains. In the current literature, there lacks a well-developed interface to enable multi-resolution simulation of vehicle, traffic, virtual environment, and hardware-in-the-loop (HIL) simulation. In this work, a modular and flexible interface is developed to enable multi-resolution vehicle and traffic co-simulation for CAV applications. This interface is built upon Oak Ridge National Laboratory’s (ORNL’s) Real-Sim approach, can support various simulation tools and real-time X-in-the-loop (XIL) simulations, and is based on network communication protocols. The network communication delays are analyzed for simultaneous connection of up to 20 simulators. Then, two example applications are studied to demonstrate the potential usage of the Real-Sim interface: (1) a centralized merging scenario where the dynamics of two ego vehicles are emulated with detailed vehicle and powertrain dynamics models and (2) a signal-controller-in-the-loop (SCIL) evaluation where one intersection of the simulated traffic scenario is controlled by a physical signal controller. This Real-Sim interface is a tool that allows researchers to bring real, tangible hardware and software into simulated environments to comprehensively evaluate and support a wide variety of CAV applications.

33 ADVANCED PROPULSION SYSTEMS↗

SU-F-J-181: An Alternative Patient Alignment Tool On TomoTherapy: The First In- Human Megavoltage-Topogram Acquisition

Purpose: To show the first in-human Megavoltage (MV)-Topogram acquisition for the evaluation of the potential for MV-Topogram-based alignment as an alternative to MVCT for reducing dose and imaging time. Methods: A lung cancer patient was enrolled in an ongoing IRB-approved clinical trial at our institute. The patient was set up using the clinical protocol employing positioning lasers. 3.2mm diameter tungsten spheres were placed on the patient’s skin at their alignment tattoos to check surface-based marker concordance between topograms and MVCT. Anterior-Posterior (AP) and lateral (LAT) MV-Topograms were acquired using gantry angles of 0°/90° with a 1mm collimator opening, all MLC leafs open, 4cm/s couch speed, and 12.5s scanning time. The topogram acquisition was immediately followed by the normal MVCT scan acquisition. MV-Topograms were reconstructed from the detector exit-data using in-house developed software. The topograms were also enhanced using contrast-limited adaptive histogram equalization (CLAHE). The MV-Topograms were registered to reference kV-based digitally reconstructed topograms. The localization results were compared against results obtained comparing the clinical MVCT to the kVCT simulation. Results: The shifts using the unenhanced Topograms, enhanced Topograms, and MVCT were (LAT, LONG, VERT, ROLL) (5.8mm, 2.6mm, −5.6mm, 0.34°), (3.9mm, 2.5mm, −2.2mm, 0.65°) and (2.4mm, 1.5mm, −3.0mm, 0.5°), respectively. The magnitude alignment differences between the enhanced Topograms and MVCT were within 1.5 mm and 0.15°. The average MVCT and total Topogram acquisition times were 272.9s ± 31.5s and 46s, respectively. Conclusion: MV-Topograms have the potential for providing equivalent performance with less dose and acquisition time than the traditional MVCT technique. We are evaluating other sites as well as adding patients to develop statistically significant analyses regarding the alignment quality differences. MV-Topograms are likely to be most clinically useful for bony anatomy and radiopaque marker-based alignments. The study was supported by an Accuray Grant.

60 APPLIED LIFE SCIENCES↗

Optimization of electroporation method and promoter evaluation for type-1 methanotroph, Methylotuvimicrobium alcaliphilum

Methanotrophic bacteria are promising hosts for methane bioconversion to biochemicals or bioproducts. However, due to limitations associated with long genetic manipulation timelines and, lack of choice in genetic tools required for strain engineering, methanotrophs are currently not employed for bioconversion technologies. In this study, a rapid and reproducible electroporation protocol is developed for type 1 methanotroph, Methylotuvimicrobium alcaliphilum using common laboratory solutions, analyzing optimal electroshock voltages and post-shock cell recovery time. Successful reproducibility of the developed method was achieved when different replicative plasmids were assessed on lab adapted vs. wild-type M. alcaliphilum strains (DASS vs. DSM19304). Overall, a ∼ 3-fold decrease in time is reported with use of electroporation protocol developed here, compared to conjugation, which is the traditionally employed approach. Additionally, an inducible (3-methyl benzoate) and a constitutive (sucrose phosphate synthase) promoter is characterized for their strength in driving gene expression.

59 BASIC BIOLOGICAL SCIENCES↗

Commissioning and dosimetric characteristics of TrueBeam system: Composite data of three TrueBeam machines

Purpose: A TrueBeam linear accelerator (TB-LINAC) is designed to deliver traditionally flattened and flattening-filter-free (FFF) beams. Although it has been widely adopted in many clinics for patient treatment, limited information is available related to commissioning of this type of machine. In this work, commissioning data of three units were measured, and multiunit comparison was presented to provide valuable insights and reliable evaluations on the characteristics of the new treatment system. Methods: The TB-LINAC is equipped with newly designed waveguide, carousel assembly, monitoring control, and integrated imaging systems. Each machine in this study has 4, 6, 8, 10, 15 MV flattened photon beams, and 6 MV and 10 MV FFF photon beams as well as 6, 9, 12, 16, 20, and 22 MeV electron beams. Dosimetric characteristics of the three new TB-LINAC treatment units are systematically measured for commissioning. High-resolution diode detectors and ion chambers were used to measure dosimetric data for a range of field sizes from 10 Multiplication-Sign 10 to 400 Multiplication-Sign 400 mm{sup 2}. The composite dosimetric data of the three units are presented in this work. The commissioning of intensity modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT), image-guided radiation therapy, and gating systems are also illustrated. Critical considerations of P{sub ion} of FFF photon beams and small field dosimetric measurements were investigated. Results: The authors found all PDDs and profiles matched well among the three machines. Beam data were quantitatively compared and combined through average to yield composite beam data. The discrepancies among the machines were quantified using standard deviation (SD). The mean SD of the PDDs among the three units is 0.12%, and the mean SD of the profiles is 0.40% for 10 MV FFF open fields. The variations of P{sub ion} of the chamber CC13 is 1.2 {+-} 0.1% under 6 MV FFF and 2.0 {+-} 0.5% under 10 MV FFF from dmax to the 18 cm-off-axis point at 35 cm depth under 40 Multiplication-Sign 40 cm{sup 2}. The mean penumbra of crossplane flattened photon beams at collimator angle of 0 Degree-Sign is measured from 5.88 {+-} 0.09 to 5.99 {+-} 0.13 mm from 4 to 15 MV at 10 cm depth of 100 Multiplication-Sign 100 mm{sup 2}. The mean penumbra of crossplane beams at collimator angle of 0 Degree-Sign is measured as 3.70 {+-} 0.21 and 4.83 {+-} 0.04 mm for 6 MV FFF and 10 MV FFF, respectively, at 10 cm depth with a field size of 5 Multiplication-Sign 5 cm{sup 2}. The end-to-end test procedures of both IMRT and VMAT were performed for various energy modes. The mean ion chamber measurements of three units showed less than 2% between measurement and calculation; the mean MultiCube ICA measurements demonstrated over 90% pixels passing gamma analysis (3%, 3 mm, 5% threshold). The imaging dosimetric data of KV planar imaging and CBCT demonstrated improved consistency with vendor specifications and dose reduction for certain imaging protocols. The gated output verification showed a discrepancy of 0.05% or less between gating radiation delivery and nongating radiation delivery. Conclusions: The commissioning data indicated good consistency among the three TB-LINAC units. The commissioning data provided us valuable insights and reliable evaluations on the characteristics of the new treatment system. The systematically measured data might be useful for future reference.

07 ISOTOPE AND RADIATION SOURCES↗

Phase 1/2 Trials of Temozolomide, Motexafin Gadolinium, and 60-Gy Fractionated Radiation for Newly Diagnosed Supratentorial Glioblastoma Multiforme: Final Results of RTOG 0513

Purpose: The purpose of phase 1 was to determine the maximum tolerated dose (MTD) of motexafin gadolinium (MGd) given concurrently with temozolomide (TMZ) and radiation therapy (RT) in patients with newly diagnosed supratentorial glioblastoma multiforme (GBM). Phase 2 determined whether this combination improved overall survival (OS) and progression-free survival (PFS) in GBM recursive partitioning analysis class III to V patients compared to therapies for recently published historical controls. Methods and Materials: Dose escalation in phase 1 progressed through 3 cohorts until 2 of 6 patients experienced dose-limiting toxicity or a dose of 5 mg/kg was reached. Once MTD was established, a 1-sided 1-sample log-rank test at significance level of .1 had 85% power to detect a median survival difference (13.69 vs 18.48 months) with 60 deaths over a 12-month accrual period and an additional 18 months of follow-up. OS and PFS were estimated using the Kaplan-Meier method. Results: In phase 1, 24 patients were enrolled. The MTD established was 5 mg/kg, given intravenously 5 days a week for the first 10 RT fractions, then 3 times a week for the duration of RT. The 7 patients enrolled in the third dose level and the 94 enrolled in phase 2 received this dose. Of these 101 patients, 87 were eligible and evaluable. Median survival time was 15.6 months (95% confidence interval [CI]: 12.9-17.6 months), not significantly different from that of the historical control (P=.36). Median PFS was 7.6 months (95% CI: 5.7-9.6 months). One patient (1%) experienced a grade 5 adverse event possibly related to therapy during the concurrent phase, and none experience toxicity during adjuvant TMZ therapy. Conclusions: Treatment was well tolerated, but median OS did not reach improvement specified by protocol compared to historical control, indicating that the combination of standard RT with TMZ and MGd did not achieve a significant survival advantage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ultrasonic Studies of Composites Undergoing Thermal and Fatigue Loading

New composite materials possess attractive properties for use in advanced aircraft. A necessary requirement for their introduction into aeronautic use is an accurate understanding of their long term aging processes so that proper design criteria can be established. In order to understand those properties, these composites must be exposed to thermal and load cycles that are characteristic of flight conditions. Additionally, airline companies will require nondestructive evaluation (NDE) methods that can be used in the field to assess the condition of these new materials as they age. As part of an effort to obtain the required information about new composites for aviation use, we are performing ultrasonic measurements both in the NDE laboratory and in the materials testing laboratory at NASA. The materials testing laboratory is equipped with environmental chambers mounted on load frames so that composite samples can be exposed to thermal and loading cycles representative of flight protocols. Applying both temperature and load simultaneously will help to highlight temperature and load interactions during the aging of these composite materials. This study reports on our initial ultrasonic attenuation results from thermoset and thermoplastic composite samples. Ultrasonic attenuation measurements have been used reliably to assess the effects of material degradation. For example, recently, researchers have shown that by using frequencies of ultrasound on the order of 24 MHz, they could obtain adequate contrast in the evaluation of thermal degradation in these composites. This paper will present data that shows results at a lower frequency range. In addition, we report results on the frequency dependence of attenuation as the slope of attenuation with respect to frequency, beta = delta alpha (f) / delta f. The slope of attenuation is an attractive parameter since it is quantitative, yet does not require interface corrections like conventional quantitative attenuation measurements. This is a consequence of the assumption that interface correction terms are frequently independent. Uncertainty in those corrections terms compromises the value of conventional quantitative attenuation data.

Madaras, Eric I.↗

The Applications of Intumescent Technologies in Support of D and D Activities across the DOE Complex - 19599

The development of intumescent technologies to be used as both an excellent means of fire protection and resiliency and as a radioactive fixative, would most definitely benefit the safety of the general public and also the environment. The remediation and safe disposal of radioactive waste is of great important to both national security and the public health, as we carry the responsibility to not develop new ways of mitigating these hazards but also to lay the groundwork for future generations. The overall goal of this research is to enhance the fire resiliency and protection of fixatives and nuclear facilities in support of D and D activities. Specific objectives include: 1) identify and evaluate commercial-off-the-shelf (COTS) intumescent technologies, 2) conduct baseline fire testing of intumescent technologies, 3) develop a set of international standards to meet operational and safety requirements for D and D Technologies. In order to evaluate the above proposed research objectives, the following hypotheses have been postulated. - Select, test, and evaluate the suitability of certain 'near fit' ASTM flammability standards. - Baseline and down-select a set of existing COTS intumescent technologies (coatings and foams) to support D and D problem sets. - Determine feasibility of application methods for use inside a radioactive glovebox and hot cells for D and D purposes. - Develop international testing protocols for adapting the use of intumescent technologies to address needs of the D and D process. The proposed research will primarily take place at FIU-ARC. ARC and SRNL have conducted extensive coordination with the Savannah River Site's (SRS) 235-F PuFF facility personnel to facilitate planning in order to expedite the research and development (R and D) related to this effort. An initial set of documents associated with the specific facility hot cells, including schematics, assessment of the manipulator arms, anticipated particulate sizes of the Pu-238 contamination, an approved tooling list, etc., were formally reviewed and approved for release by the site to ARC. Utilizing these as a foundation, pre-planning for further adaptation of the intumescent technologies and the application during a full-scale cold demo at a hot cell testbed at ARC. One of the primary objectives is the testing and evaluation of the resistance of radiological shielding foams to thermal stressors. This objective was accomplished by conducting a flammability test and incremental temperature test. The goal of the flammability test is to conduct analytical tests to provide a classification for the foams as outlined below in accordance with IEC 60695-11-10. This test method is uniformly accepted throughout the industry as being critical indicators that quantifiably establish the flammability characteristics of plastics. It should be noted that polyurethane is not classified as a plastic, however, they do share similar properties deeming this a near fit test. IEC 60695-11-10:2013 specifies small-scale laboratory test procedures intended to compare the burning behavior of different materials when vertically or horizontally oriented test bar specimens are exposed to a small flame ignition source. Two test methods are described. Method A is a horizontal burning test and is intended to determine the linear burning rate of materials under specific test conditions. Method B is a vertical burning test and is intended to determine whether materials self-extinguish under specific test conditions. The purpose of the incremental temperature testing is to evaluate mass loss and dimensional changes that occurs to the radiological shielding foams when exposed to high temperatures in a muffle furnace. High temperatures often cause materials to undergo physical changes such as swelling or expanding. This is caused by the increase in kinetic energy and atomic and molecular movement.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Generation and functional evaluation of designer monoterpene synthases

Monoterpene synthases are highly versatile enzymes that catalyze the first committed step in the pathways toward terpenoids, the structurally most diverse class of plant natural products. Current advancements in our understanding of the reaction mechanism have enabled engineering approaches to develop mutant monoterpene synthases that produce specific monoterpenes. Here, we are describing protocols to introduce targeted mutations, express mutant enzyme catalysts in heterologous hosts, and assess their catalytic properties. Mutant monoterpene synthases have the potential to contribute significantly to synthetic biology efforts aimed at producing larger amounts of commercially attractive monoterpenes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-F-BRE-06: Evaluation of Patient CT Dose Reconstruction From 3D Diode Array Measurements Using Anthropomorphic Phantoms

Purpose: To compare 3D reconstructed dose of IMRT plans from 3D diode array measurements with measurements in anthropomorphic phantoms. Methods: Six IMRT plans were created for the IROC Houston (RPC) head and neck (H and N) and lung phantoms following IROC Houston planning protocols. The plans included flattened and unflattened beam energies ranging from 6 MV to 15 MV and both static and dynamic MLC tecH and Niques. Each plan was delivered three times to the respective anthropomorphic phantom, each of which contained thermoluminescent dosimeters (TLDs) and radiochromic films (RCFs). The plans were also delivered to a Delta4 diode array (Scandidos, Uppsala, Sweden). Irradiations were done using a TrueBeam STx (Varian Medical Systems, Palo Alto, CA). The dose in the patient was calculated by the Delta4 software, which used the diode measurements to estimate incident energy fluence and a kernel-based pencil beam algorithm to calculate dose. The 3D dose results were compared with the TLD and RCF measurements. Results: In the lung, the average difference between TLDs and Delta4 calculations was 5% (range 2%–7%). For the H and N, the average differences were 2.4% (range 0%–4.5%) and 1.1% (range 0%–2%) for the high- and low-dose targets, respectively, and 12% (range 10%-13%) for the organ-at-risk simulating the spinal cord. For the RCF and criteria of 7%/4mm, 5%/3mm, and 3%/3mm, the average gamma-index pass rates were 95.4%, 85.7%, and 76.1%, respectively for the H and N and 76.2%, 57.8%, and 49.5% for the lung. The pass-rate in the lung decreased with increasing beam energy, as expected for a pencil beam algorithm. Conclusion: The H and N phantom dose reconstruction met the IROC Houston acceptance criteria for clinical trials; however, the lung phantom dose did not, most likely due to the inaccuracy of the pencil beam algorithm in the presence of low-density inhomogeneities. Work supported by PHS grant CA10953 and CA81647 (NCI, DHHS)

60 APPLIED LIFE SCIENCES↗

Localization properties and high-fidelity state transfer in hopping models with correlated disorder

We investigate a tight-binding chain featuring diagonal and off-diagonal disorder, these being modeled through the long-range-correlated fractional Brownian motion. Particularly, by employing exact diagonalization methods, we evaluate how the eigenstate spectrum of the system and how its related single-particle dynamics respond to both competing sources of disorder. Moreover, we report the possibility of carrying out efficient end-to-end quantum-state transfer protocols even in the presence of such generalized disorder due to the appearance of extended states around the middle of the band in the limit of strong correlations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Seamless integration of commercial Clouds with ATLAS Distributed Computing

The CERN ATLAS Experiment successfully uses a worldwide dis-tributed computing Grid infrastructure to support its physics programme at the Large Hadron Collider (LHC). The Grid workflow system PanDA routinely manages up to 700,000 concurrently running production and analysis jobs to process simulation and detector data. In total more than 500 PB of data are distributed over more than 150 sites in the WLCG and handled by the ATLAS data management system Rucio. To prepare for the ever growing data rate in future LHC runs new developments are underway to embrace industry accepted protocols and technologies, and utilize opportunistic resources in a standard way. This paper reviews how the Google and Amazon Cloud computing ser-vices have been seamlessly integrated as a Grid site within PanDA and Rucio. Performance and brief cost evaluations will be discussed. Such setups could offer advanced Cloud tool-sets and provide added value for analysis facilities that are under discussions for LHC Run-4.

97 MATHEMATICS AND COMPUTING↗