Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Redox-Dependent Conformational Changes in Cytochrome c Oxidase Suggest a Gating Mechanism for Proton Uptake

A role for conformational change in the coupling mechanism of cytochrome c oxidase is the subject of controversy. Relatively small conformational changes have been reported in comparisons of reduced and oxidized crystal structures of bovine oxidase but none in bacterial oxidases. Comparing the X-ray crystal structures of the reduced (at 2.15 {angstrom} resolution) and oxidized forms of cytochrome c oxidase from Rhodobacter sphaeroides, we observe a displacement of heme a3 involving both the porphyrin ring and the hydroxyl farnesyl tail, accompanied by protein movements in nearby regions, including the mid part of helix VIII of subunit I which harbors key residues of the K proton uptake path, K362 and T359. The conformational changes in the reduced form are reversible upon reoxidation. They result in an opening of the top of the K pathway and more ordered waters being resolved in that region, suggesting an access path for protons into the active site. In all high-resolution structures of oxidized R. sphaeroides cytochrome c oxidase, a water molecule is observed in the hydrophobic region above the top of the D path, strategically positioned to facilitate the connection of residue E286 of subunit I to the active site or to the proton pumping exit path. In the reduced and reduced plus cyanide structures, this water molecule disappears, implying disruption of proton conduction from the D path under conditions when the K path is open, thus providing a mechanism for alternating access to the active site.

36 MATERIALS SCIENCE↗

Chemical Characterization of Crude Petroleum Using Nanospray Desorption Electrospray Ionization Coupled with High-Resolution Mass Spectrometry

Nanospray desorption electrospray ionization (nano-DESI) combined with high-resolution mass spectrometry was used for the first time for the analysis of liquid petroleum crude oil samples. The analysis was performed in both positive and negative ionization modes using three solvents one of which (acetonitrile/toluene mixture) is commonly used in petroleomics studies while two other polar solvents (acetonitrile/water and methanol/water mixtures) are generally not compatible with petroleum characterization using mass spectrometry. The results demonstrate that nano-DESI analysis efficiently ionizes petroleum constituents soluble in a particular solvent. When acetonitrile/toluene is used as a solvent, nano-DESI generates electrospray-like spectra. In contrast, strikingly different spectra were obtained using acetonitrile/water and methanol/water. Comparison with the literature data indicates that these solvents selectively extract water-soluble constituents of the crude oil. Water-soluble compounds are predominantly observed as sodium adducts in nano-DESI spectra indicating that addition of sodium to the solvent may be a viable approach for efficient ionization of water-soluble crude oil constituents. Nano-DESI enables rapid screening of different classes of compounds in crude oil samples using solvents that are rarely used for petroleum characterization.

02 PETROLEUM↗

A photoelectron-photoion coincidence imaging apparatus for femtosecond time-resolved molecular dynamics with electron time-of-flight resolution of {sigma}=18 ps and energy resolution {delta}E/E=3.5%

We report on the construction and performance of a novel photoelectron-photoion coincidence machine in our laboratory in Amsterdam to measure the full three-dimensional momentum distribution of correlated electrons and ions in femtosecond time-resolved molecular beam experiments. We implemented sets of open electron and ion lenses to time stretch and velocity map the charged particles. Time switched voltages are operated on the particle lenses to enable optimal electric field strengths for velocity map focusing conditions of electrons and ions separately. The position and time sensitive detectors employ microchannel plates (MCPs) in front of delay line detectors. A special effort was made to obtain the time-of-flight (TOF) of the electrons at high temporal resolution using small pore (5 {mu}m) MCPs and implementing fast timing electronics. We measured the TOF distribution of the electrons under our typical coincidence field strengths with a temporal resolution down to {sigma}=18 ps. We observed that our electron coincidence detector has a timing resolution better than {sigma}=16 ps, which is mainly determined by the residual transit time spread of the MCPs. The typical electron energy resolution appears to be nearly laser bandwidth limited with a relative resolution of {delta}E{sub FWHM}/E=3.5% for electrons with kinetic energy near 2 eV. The mass resolution of the ion detector for ions measured in coincidence with electrons is about {delta}m{sub FWHM}/m=1/4150. The velocity map focusing of our extended source volume of particles, due to the overlap of the molecular beam with the laser beams, results in a parent ion spot on our detector focused down to {sigma}=115 {mu}m.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE CATALOG OF POSITIONS OF OPTICALLY BRIGHT EXTRAGALACTIC RADIO SOURCES OBRS-2

Future space-borne astrometry missions, such as Gaia, will be able to determine the optical positions of hundreds of quasars with submilliarcsecond accuracies comparable to those achieved in radio by very long baseline interferometry (VLBI). Comparisons of coordinate systems from space-borne missions and VLBI will be very important, first for investigations of possible systematic errors and second for investigations of possible shifts between centroids of radio and optical emissions in active galactic nuclei. In order to make such a comparison more robust, a program for densification of the grid of radio sources detectable with both VLBI and Gaia was launched in 2006. Program sources are 398 quasars with declinations > - 10 Degree-Sign that are brighter than 18 mag at the V band. The first two observing campaigns were run in 2007-2008. In the third campaign, a set of 291 objects from that list was observed with the VLBA+EVN in 2010-2011 with the primary goal of producing their images with milliarcsecond resolution. In this paper, following the method of absolute astrometry, coordinates of observed sources have been derived with milliarcsecond accuracies from analysis of these observations. The catalog of positions of 295 target sources, estimates of their correlated flux densities at 2.2 and 8.4 GHz, and their images are presented. The accuracies of source coordinates are in a range of 2-200 mas, with a median of 3.2 mas.

79 ASTRONOMY AND ASTROPHYSICS↗

Large Time Projection Chambers for Rare Event Detection

The Time Projection Chamber (TPC) concept [add ref to TPC section] has been applied to many projects outside of particle physics and the accelerator based experiments where it was initially developed. TPCs in non-accelerator particle physics experiments are principally focused on rare event detection (e.g. neutrino and darkmater experiments) and the physics of these experiments can place dramatically different constraints on the TPC design (only extensions to the traditional TPCs are discussed here). The drift gas, or liquid, is usually the target or matter under observation and due to very low signal rates a TPC with the largest active mass is desired. The large mass complicates particle tracking of short and sometimes very low energy particles. Other special design issues include, efficient light collection, background rejection, internal triggering and optimal energy resolution. Backgrounds from gamma-rays and neutrons are significant design issues in the construction of these TPCs. They are generally placed deep underground to shield from cosmogenic particles and surrounded with shielding to reduce radiation from the local surroundings. The construction materials have to be carefully screened for radiopurity as they are in close contact with the active mass and can be a signification source of background events. The TPC excels in reducing this internal background because the mass inside the fieldcage forms one monolithic volume from which fiducial cuts can be made ex post facto to isolate quiet drift mass, and can be circulated and purified to a very high level. Self shielding in these large mass systems can be significant and the effect improves with density. The liquid phase TPC can obtain a high density at low pressure which results in very good self-shielding and compact installation with a lightweight containment. The down sides are the need for cryogenics, slower charge drift, tracks shorter than the typical electron diffusion, lower energy resolution (e.g. xenon) and limited charge readout options. Slower charge drift requires long electron lifetimes placing strict limits on the oxygen and other impurities with high electron affinity. A significant variation of the liquid phase TPC, that improves the charge readout, is the dual-phase TPC where a gas phase layer is formed above the liquid into which the drifting electrons are extracted and amplified, typically with electroluminescence. The successful transfer of electrons through the phase boundary requires careful control of its position and setting up an appropriate electric field. A high pressure gas phase TPC has no cryogenics and density is easily optimized for the signal, but a large heavy pressure vessel is required. Although shelf shielding is reduced, it can in some cases approach that of the liquid phase; in xenon at 50atm the density is about half that of water or about 1/6 of liquid xenon. A significant feature of high pressure xenon gas is the energy resolution. Below a density of about 0.5g/cc the intrinsic resolution is only a few times that of high purity germanium. A neutrino-less double beta decay (0{nu}2{beta}) TPC operated below this density limit could enjoy excellent energy resolution and maintain particle tracking for background rejection. An observable interaction with the TPC results in a charged particle that travels in the drift matter exciting and ionizing the atoms until the initial energy is converted into ionization, scintillation, or heat with relatively large fluctuations around a mean distribution. Rare event TPCs can be designed to detect scintillation light as well as charge to exploit the anti-correlation to improve energy resolution and/or signal to noise. An electric drift field separates the electrons and positive ions from the ionization although the separation is not complete and some electrons are captured, exciting atoms and releasing more light than the primary excitation alone. The average partition between the scintillation and ionization can be manipulated to increase the ionization (at a loss of scintillation) by a number of methods such as, increasing the strength of the electric field up to a saturation of the ionization yield, increasing the temperature to enhance the diffusion of the ionized electrons, and adding dopants such as triethylamine that can be photoionized by the scintillation photons releasing more ionization. Scintillation light is typically collected with photomultiplier tubes (PMTs) and avalanche photo diodes (APDs) although any fast (compared to the ionization drift speed) light collector capable of detecting the typically UV photons, maintaining high radiopurity and perhaps withstanding pressure would work. CCDs are slow and therefore only record 2 dimensions integrating over the time direction, some of which can be recovered with a few PMTs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-energy x-ray imaging and sensing for diagnostic and control of the burning plasma

New diagnostic and sensor designs are needed for future burning plasma (BP) fusion experiments, having good space and time resolution and capable of prolonged operation in the harsh BP environment. We evaluate the potential of multi-energy x-ray imaging with filtered detector arrays for BP diagnostic and control. Experimental studies show that this simple and robust technique enables measuring with good accuracy, speed, and spatial resolution the T{sub e} profile, impurity content, and MHD activity in a tokamak. Applied to the BP this diagnostic could also serve for non-magnetic sensing of the plasma position, centroid, ELM, and RWM instability. BP compatible x-ray sensors are proposed using 'optical array' or 'bi-cell' detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photodissociation resonances of jet-cooled NO{sub 2} at the dissociation threshold by CW-CRDS

Around 398 nm, the jet-cooled-spectrum of NO{sub 2} exhibits a well identified dissociation threshold (D{sub 0}). Combining the continuous-wave absorption-based cavity ringdown spectroscopy technique and laser induced fluorescence detection, an energy range of ∼25 cm{sup −1} is analyzed at high resolution around D{sub 0}. In addition to the usual molecular transitions to long-lived energy levels, ∼115 wider resonances are observed. The position, amplitude, and width of these resonances are determined. The resonance width spreads from ∼0.006 cm{sup −1} (i.e., ∼450 ps) to ∼0.7 cm{sup −1} (∼4 ps) with large fluctuations. The identification of at least two ranges of resonance width versus the excess energy can be associated with the opening of the dissociation channels NO{sub 2}→NO(X {sup 2}Π{sub 1/2}, v=0, J=1/2)+O({sup 3}P{sub 2}) and NO{sub 2}→NO(X {sup 2}Π{sub 1/2}, v=0, J=3/2)+O({sup 3}P{sub 2}). This analysis corroborates the existence of loose transition states close to the dissociation threshold as reported previously and in agreement with the phase space theory predictions as shown by Tsuchiya’s group [Miyawaki et al., J. Chem. Phys. 99, 254–264 (1993)]. The data are analyzed in the light of previously reported frequency- and time-resolved data to provide a robust determination of averaged unimolecular dissociation rate coefficients. The density of reactant levels deduced (ρ{sub reac} ∼ 11 levels/cm{sup −1}) is discussed versus the density of transitions, the density of resonances, and the density of vibronic levels.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

THE DETECTION AND STATISTICS OF GIANT ARCS BEHIND CLASH CLUSTERS

We developed an algorithm to find and characterize gravitationally lensed galaxies (arcs) to perform a comparison of the observed and simulated arc abundance. Observations are from the Cluster Lensing And Supernova survey with Hubble (CLASH). Simulated CLASH images are created using the MOKA package and also clusters selected from the high-resolution, hydrodynamical simulations, MUSIC, over the same mass and redshift range as the CLASH sample. The algorithm's arc elongation accuracy, completeness, and false positive rate are determined and used to compute an estimate of the true arc abundance. We derive a lensing efficiency of 4 ± 1 arcs (with length ≥6″ and length-to-width ratio ≥7) per cluster for the X-ray-selected CLASH sample, 4 ± 1 arcs per cluster for the MOKA-simulated sample, and 3 ± 1 arcs per cluster for the MUSIC-simulated sample. The observed and simulated arc statistics are in full agreement. We measure the photometric redshifts of all detected arcs and find a median redshift z{sub s} = 1.9 with 33% of the detected arcs having z{sub s} > 3. We find that the arc abundance does not depend strongly on the source redshift distribution but is sensitive to the mass distribution of the dark matter halos (e.g., the c–M relation). Our results show that consistency between the observed and simulated distributions of lensed arc sizes and axial ratios can be achieved by using cluster-lensing simulations that are carefully matched to the selection criteria used in the observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Direct Imaging of the Spatial and Energy Distribution of Nucleation Centers in Ferroelectric Materials

Macroscopic ferroelectric polarization switching, similar to other first order phase transitions, is controlled by nucleation centers. Despite 50 years of extensive theoretical and experimental effort, the microstructural origins of the Landauer paradox, i.e. the experimentally observed low values of coercive fields in ferroelectrics corresponding to implausibly large nucleation activation energies, are still a mystery. In this letter, we develop an approach to visualize the nucleation centers controlling polarization switching processes with nanometer resolution, determine their spatial and energy distribution, and correlate them to local microstructure. The random bond and random field components of the disorder potential are extracted from positive and negative nucleation biases. Observation of enhanced nucleation activity at the 90 domain wall boundaries and intersections combined with phase-field modeling identifies them as a class of nucleation centers that control switching in structural-defect free materials.

36 MATERIALS SCIENCE↗

TOPOS: A new topometric patient positioning and tracking system for radiation therapy based on structured white light

Purpose: A patient positioning system for radiation therapy based on structured white light and using off-the-shelf hardware components for flexibility and cost-effectiveness has been developed in house. Increased accuracy, patient comfort, abandonment of any skin marks, accelerated workflow, objective reading/recording, better usability and robust sensor design, compared to other positioning approaches, were the main goals of this work. Another aim was the application of a 6 degrees of freedom tracking system working without dose deposition. Methods: Two optical sensors are the main parts of the TOPOS Registered-Sign system (Topometrical Positioning, cyberTECHNOLOGIES, Germany). The components: cameras, projectors, and computers are commercial off-the-shelf products, allowing for low production costs. The black/white cameras of the prototype are capable of taking up to 240 frames per second (resolution: 640 Multiplication-Sign 488 pixels). The projector has a resolution of 1024 Multiplication-Sign 768 and a refresh rate of 120 Hz. The patient's body surface is measured continuously and registered to a reference surface, providing a transformation to superimpose the patient's surface to the reference (planning CT) surface as best as possible. The execution of the calculated transformation provides the correct patient position before the treatment starts. Due to the high-speed acquisition of the surfaces, a surveillance of the patient's (respiration) motion during treatment is also accomplished. The accuracy of the system was determined using a male mannequin. Two treatment sites were evaluated: one simulating a head and neck treatment and the other simulating a thoracic wall treatment. The mannequin was moved to predefined positions, and shift vectors given by the surface registration were evaluated. Additionally manual positioning using a color-coding system was evaluated. Results: Two prototypes have been developed, each allowing a continuous high density scan of a 500 Multiplication-Sign 500 Multiplication-Sign 400 mm{sup 3} (L Multiplication-Sign W Multiplication-Sign D) large volume with a refresh rate of 10 Hz (extendible to 20 Hz for a single sensor system). Surface and position correction display, as well as respiratory motion, is shown in real-time (delay < 200 ms) using present graphical hardware acceleration. For an intuitive view of the patient's misalignment, a fast surface registration algorithm has been developed and tested and a real-time color-coding technique is proposed and verified that allows the user to easily verify the position of the patient. Using first the surface registration and then the color coding the best results were obtained: for the head and neck case, the mean difference between the actual zero position and the final match was 0.1 {+-} 0.4, -0.2 {+-} 0.7, and -0.1 {+-} 0.3 mm in vertical, longitudinal, and lateral direction. For the thoracic case, the mean differences were 0.3 {+-} 0.5, -0.6 {+-} 1.9, 0.0 {+-} 0.4 mm. Conclusions: The presented system copes with the increasing demand for more accurate patient positioning due to more precise irradiation technologies and minimizes the preparation times for correct patient alignment, therefore optimizing the treatment workflow. Moreover, TOPOS is a versatile and cost effective image guided radiation therapy device. It allows an objective rating of the patient's position before and during the irradiation and could also be used for respiratory gating or tracking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved Localization Precision and Angular Resolution of a Cylindrical, Time-Encoded Imaging System From Adaptive Detector Movements

To the first order, the localization precision and angular resolution of a cylindrical, time-encoded imaging (c-TEI) system is governed by the geometry of the system. Improving either measure requires increasing the mask radius or decreasing the detector diameter, both of which are undesirable. Here, we propose an alternative option of repositioning the detector within the mask to increase the detector-to-mask distance in the direction of a source, thereby improving the localization precision and angular resolution in that direction. Since the detector-to-mask distance only increases for a small portion of the field of view (FOV), we propose implementing adaptive imaging where one leverages data collected during the measurement to optimize the system configuration. This article utilizes both simulations and experiments to set upper bounds on the potential gain from adaptive detector movements for one and two sources in the FOV. When only one source is present, adaptive detector movements can improve the localization precision and angular resolution by 20% for a source at 90 cm and by 32% for a far-field source. When two sources are present, adaptive detector movements can improve localization precision and angular resolution by up to 50% for sources that are ~10° apart (90 cm from the system). We experimentally verify these results through maximum likelihood estimation of the source position(s) and image reconstruction of point sources that are close together. As a demonstration of an adaptive imaging algorithm, we image a complex arrangement of special nuclear material at the Zero Power Physics Reactor facility at Idaho National Laboratory.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Determining the Effectiveness of Incorporating Geographic Information Into Vehicle Performance Algorithms

This thesis presents a research study using one year of driving data obtained from plug-in hybrid electric vehicles (PHEV) located in Sacramento and San Francisco, California to determine the effectiveness of incorporating geographic information into vehicle performance algorithms. Sacramento and San Francisco were chosen because of the availability of high resolution (1/9 arc second) digital elevation data. First, I present a method for obtaining instantaneous road slope, given a latitude and longitude, and introduce its use into common driving intensity algorithms. I show that for trips characterized by >40m of net elevation change (from key on to key off), the use of instantaneous road slope significantly changes the results of driving intensity calculations. For trips exhibiting elevation loss, algorithms ignoring road slope overestimated driving intensity by as much as 211 Wh/mile, while for trips exhibiting elevation gain these algorithms underestimated driving intensity by as much as 333 Wh/mile. Second, I describe and test an algorithm that incorporates vehicle route type into computations of city and highway fuel economy. Route type was determined by intersecting trip GPS points with ESRI StreetMap road types and assigning each trip as either city or highway route type according to whichever road type comprised the largest distance traveled. The fuel economy results produced by the geographic classification were compared to the fuel economy results produced by algorithms that assign route type based on average speed or driving style. Most results were within 1 mile per gallon ({approx}3%) of one another; the largest difference was 1.4 miles per gallon for charge depleting highway trips. The methods for acquiring and using geographic data introduced in this thesis will enable other vehicle technology researchers to incorporate geographic data into their research problems.

58 GEOSCIENCES↗

Development of X-ray Beam Position Monitors for Superconducting Wiggler

For the development of an X-ray beam position monitor (XBPM) for the superconducting wiggler (SW) at the NSRRC, two XBPM are installed in the SW front end. The blades of the XBPM were manufactured with material of three types; tungsten, Glidcop and aluminium, to test the effect of the material on the performance of the XBPM. These three materials are compared with blades of molybdenum that were previously installed. The vibration and thermal expansion of the pillar of a XBPM affects the position reading of the XBPM. For pillars of XBPM of various designs, each type has a distinct thermal isolating material and is filled with a separate damping material for comparison. The design requirements of these XBPM include high spatial resolution of the monitor and mechanical stability of the structure with a large thermal load. The design, fabrication and measurement results are presented here.

43 PARTICLE ACCELERATORS↗

Crystal structure of yeast Sco1

The Sco family of proteins are involved in the assembly of the dinuclear CuA site in cytochrome c oxidase (COX), the terminal enzyme in aerobic respiration. These proteins, which are found in both eukaryotes and prokaryotes, are characterized by a conserved CXXXC sequence motif that binds copper ions and that has also been proposed to perform a thiol:disulfide oxidoreductase function. The crystal structures of Saccharomyces cerevisiae apo Sco1 (apo-ySco1) and Sco1 in the presence of copper ions (Cu-ySco1) were determined to 1.8- and 2.3-{angstrom} resolutions, respectively. Yeast Sco1 exhibits a thioredoxin-like fold, similar to that observed for human Sco1 and a homolog from Bacillus subtilis. The Cu-ySco1 structure, obtained by soaking apo-ySco1 crystals in copper ions, reveals an unexpected copper-binding site involving Cys181 and Cys216, cysteine residues present in ySco1 but not in other homologs. The conserved CXXXC cysteines, Cys148 and Cys152, can undergo redox chemistry in the crystal. An essential histidine residue, His239, is located on a highly flexible loop, denoted the Sco loop, and can adopt positions proximal to both pairs of cysteines. Interactions between ySco1 and its partner proteins yeast Cox17 and yeast COX2 are likely to occur via complementary electrostatic surfaces. This high-resolution model of a eukaryotic Sco protein provides new insight into Sco copper binding and function.

36 MATERIALS SCIENCE↗

Investigation of Energy Selective Neutron Imaging at the PULSTAR Reactor

Neutron imaging is complementary to X-ray imaging where both are used to investigate the internal features of objects nondestructively. Historically, it only began three years after discovery of the neutron in 1932, however, neutron radiographs with reasonable quality were first made in the mid-fifties. Conventionally, the image is produced by placing the object between the neutron source and a two-dimensional position sensitive detector. The source commonly has a full energy spectrum (white beam) of thermal or cold neutrons to obtain high intensity in the sample and short exposure time. As a result, all neutron energies contribute to the obtained radiograph. Since the interaction of the neutron with matter is energy dependent, different energies produce different contrast on the radiographic image, hence, additional information about the object can be obtained. Neutron imaging that utilizes a narrow spectrum of energy instead of white beam is called energy selective neutron imaging. Many techniques have been explored to select a narrow band of neutron energy for the use in imaging such as the use velocity selectors, double crystal Monochromators, and time of flight techniques (at pulsed neutron sources). The PULSTAR reactor of North Carolina State University (1 MWth) currently has an operational neutron powder diffractometer (NPD) installed on beam tube no. 4, which was designed for neutron scattering experiments and can provide a monoenergetic beam of neutrons. The neutron energy could be selected by diffraction means using a Si bent perfect crystal as a Monochromator. In this work, an investigation of energy selective neutron imaging at the NPD is discussed in terms of the system performance and the ability of material discrimination on a test sample by observing the contrast variations of the neutron radiographs obtained using different neutron energies. Energy selective neutron imaging experiment was successfully tested at the PULSTAR reactor's NPD. Although, the uniform region is small and the exposure time is long in comparison with the NIF, both facilities exhibit similar spatial resolution which is a very important characteristic for any imaging facility. The contrast variation of neuron radiographs for the test sample obtained at different energies indicated a potential advantage for using energy selective neutron imaging over the white beam. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analysis of HLA-DP association with beryllium disease susceptibility in pooled exposed populations

Berylliosis or Chronic Beryllium Disease is a chronic granulomatous disorder primarily involving the lung associated with the exposition to low doses of Beryllium (Be) in the workplace. Berylliosis risk has been associated with the presence of a glutamate at position 69 of the HLA-DP beta chain (HLA-DPbetaGlu69) that is expressed in about 97% of disease cases and in 27% of the unaffected Be-exposed controls (p<0.0001) (Richeldi et al. Science 1993; 262: 242-244.12). Since this first observation of an immunogenetic association between berylliosis and HLA-DPbetaGlu69 a number of studies have confirmed the role of this marker as the primary gene of susceptibility of berylliosis (Richeldi et al Am J Ind Med. 1997; 32:337-40; Wang et al J. Immunol. 1999; 163: 1647-53; Saltini et al Eur Respir J. 2001 18:677-84; Rossman et al Am J Respir Crit Care Med. 2002 165:788-94). Moreover, a structure/function interaction between HLA-DP molecules carrying Glu69 and beryllium in driving and developing the immune response against beryllium itself has been observed as: (1) Be-specific T-cells clones obtained from berylliosis patients recognize beryllium as antigen only when presented in the context of the HLA-DP{beta}Glu69 molecules but not in the context of HLA-DP allelic variants carrying Lys69 (Lombardi G et al. J Immunol 2001; 166: 3549-3555), and (2) beryllium presents an affinity for the HLA-DP2, carrying the berylliosis marker of susceptibility HLA-DPGlu69, from 40 to 100 times higher that the HLA-DP molecule carrying Lys69 (Amicosante M. et al Hum. Immunol. 2001; 62: 686-93). However, although the immunogenetic studies performed have been addressed a number of different questions about the genetic association between berylliosis and/or beryllium sensitization, exposure levels to beryllium and HLA markers, a number of questions are still open in the field mainly due to the limitation imposed by the low number of subjects carrying berylliosis or beryllium sensitization enrolled in each immunogenetic study. In this context, the populations of the study already performed in this field by the University of Modena and Rome (by Prof. C. Saltini) and the University of Pennsylvania (by Prof. M. Rossman) have been evaluated by using similar HLA molecular typing methodologies and that both populations have now been followed up for a period of 4 to 7 years. The general objective of this study has to generate a larger data base comprising the two population with which analyze gene disease association with greater statistical power and ascertain the effect of lesser common gener variants which may be missed when analyzing associations on small populations. In particular addressing the role suggested in previous study such as: (1) the role of HLA-DP rare alleles and polymorphisms, and (2) the role of the HLA markers in disease progression from sensitization. The two populations from the already published studies (Saltini et al Eur Respir J. 2001 18:677-84; Rossman et al Am J Respir Crit Care Med. 2002 165:788-94) present similar aspects about: ethnicity, type and length of exposure to Be dust, a broadly similar association between beryllium related abnormalities and HLA. The two population have been pooled and evaluated using common criteria of diagnosis (Sensitized subject: at least 2 positive BeLPT tests each with 2 positive wells; CBD-affected subject: identification of well formed non-caseating granulomas on biopsy), follow up and HLA typing technique (complete HLA-DRB, DQB, DPB high resolution typing using amplification with sequence specific primers or sequence based typing). The two populations included 137 subjects with Beryllium hypersensitized (BH) and 155 Be-exposed controls. Inclusion criteria were met by one hundred and six subjects with Be-hypersensitivity of whom 55 were affected by CBD (age 52 {+-} 11 years; 50 caucasians, 2 African-Americans 2 Hispanics and 1 Asian; 46 males and 9 females; mean duration of Be-exposure 15 {+-} 9 years) and 51 showed Be-sensitization without lung granulomas detected by trans-bronchial biopsy (age 54 {+-} 14 years; 47 Caucasians, 3 Hispanics and 1 Afro-American; 45 males and 6 females; mean age of Be-exposure 17 {+-} 10 years) and 129 Be-exposed controls (age 53 {+-} 14 years; 120 Caucasians, 4 African-American, 4 Hispanics, 1 Asian; 104 males and 25 females; mean duration of Be-exposure 16 {+-} 10 years). Mean follow-up of BH affected subjects was 7.0 {+-} 3.7 years from the first positive Be-LPT test.

60 APPLIED LIFE SCIENCES↗

Crystallographic structure of wild-type SARS-CoV-2 main protease acyl-enzyme intermediate with physiological C-terminal autoprocessing site

Abstract Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2), the pathogen that causes the disease COVID-19, produces replicase polyproteins 1a and 1ab that contain, respectively, 11 or 16 nonstructural proteins (nsp). Nsp5 is the main protease (M pro ) responsible for cleavage at eleven positions along these polyproteins, including at its own N- and C-terminal boundaries, representing essential processing events for subsequent viral assembly and maturation. We have determined X-ray crystallographic structures of this cysteine protease in its wild-type free active site state at 1.8 Å resolution, in its acyl-enzyme intermediate state with the native C-terminal autocleavage sequence at 1.95 Å resolution and in its product bound state at 2.0 Å resolution by employing an active site mutation (C145A). We characterize the stereochemical features of the acyl-enzyme intermediate including critical hydrogen bonding distances underlying catalysis in the Cys/His dyad and oxyanion hole. We also identify a highly ordered water molecule in a position compatible for a role as the deacylating nucleophile in the catalytic mechanism and characterize the binding groove conformational changes and dimerization interface that occur upon formation of the acyl-enzyme. Collectively, these crystallographic snapshots provide valuable mechanistic and structural insights for future antiviral therapeutic development including revised molecular docking strategies based on M pro inhibition.

59 BASIC BIOLOGICAL SCIENCES↗

THE RED MSX SOURCE SURVEY: THE MASSIVE YOUNG STELLAR POPULATION OF OUR GALAXY

We present the Red MSX Source survey, the largest statistically selected catalog of young massive protostars and H II regions to date. We outline the construction of the catalog using mid- and near-infrared color selection. We also discuss the detailed follow up work at other wavelengths, including higher spatial resolution data in the infrared. We show that within the adopted selection bounds we are more than 90% complete for the massive protostellar population, with a positional accuracy of the exciting source of better than 2 arcsec. We briefly summarize some of the results that can be obtained from studying the properties of the objects in the catalog as a whole; we find evidence that the most massive stars form: (1) preferentially nearer the Galactic center than the anti-center; (2) in the most heavily reddened environments, suggestive of high accretion rates; and (3) from the most massive cloud cores.

79 ASTRONOMY AND ASTROPHYSICS↗