Search NASA⌕ Search

SEARCH · Search NASA

Results for “READOUT SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

The Simons Observatory: Magnetic Shielding Measurements for the Universal Multiplexing Module

The Simons Observatory (SO) includes four telescopes that will measure the temperature and polarization of the cosmic microwave background using over 60,000 highly sensitive transition-edge bolometers (TES). These multichroic TES bolometers are read out by a microwave RF SQUID multiplexing system with a multiplexing factor of 910. Given that both TESes and SQUIDs are susceptible to magnetic field pickup and that it is hard to predict how they will respond to such fields, it is important to characterize the magnetic response of these systems empirically. This information can then be used to limit spurious signals by informing magnetic shielding designs for the detectors and readout. This paper focuses on measurements of magnetic pickup with different magnetic shielding configurations for the SO universal multiplexing module (UMM), which contains the SQUIDs, associated resonators, and TES bias circuit. The magnetic pickup of a prototype UMM was tested under three shielding configurations: no shielding (copper packaging), aluminum packaging for the UMM, and a tin/lead-plated shield surrounding the entire dilution refrigerator 100 mK cold stage. We also present measurements of the pickup in the UMM when aluminum feedhorns are installed. The measurements show that the aluminum packaging outperforms the copper packaging by a shielding factor of 8-10, and adding the tin/lead-plated 1K shield further increases the relative shielding factor in the aluminum configuration by 1-2 orders of magnitude. Furthermore, the addition of feedhorns provides a factor of 30 improvement when the tin/lead shield is not installed and a factor of 5 improvement when it is.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Prolonging All-Optical Molecular Electron Spin Coherence in the Tissue Transparency Window

Coherent electron spin states within paramagnetic molecules hold significant potential for microscopic quantum sensing. However, all-optical coherence measurements amenable to high spatial and temporal resolution under ambient conditions remain a significant challenge. Here we conduct room-temperature, picosecond time-resolved Faraday ellipticity/rotation (TRFE/R) measurements of the electron spin decoherence time T 2 * in [IrBr 6 ] 2- . Decoherence is strongly sensitive to solution phase viscosity, pointing to molecular tumbling as an important decoherence mechanism. Accordingly, immobilization of [IrBr 6 ] 2- molecules in thin polymer films results in an order-of-magnitude increase in coherence lifetime and significantly greater magnetic field sensitivity. Here, by tuning energies of ligand-to-metal charge transfer (LMCT) states, TRFE/R enables spin initialization and readout in the tissue transparency window, paving the way toward all-optical, ultrafast molecular electron spin coherence imaging in biological systems.

Electron paramagnetic resonance spectroscopy↗

Standardisation of radiation portal monitor controls and readouts

There is an urgent need to standardise the numbering configuration of radiation portal monitor sensing panels. Currently, manufacturers use conflicting numbering schemes that may confuse operators of these varied systems. There is a similar problem encountered with the varied choices of colored indicator lights and colored print lines designated for gamma and neutron alarms. In addition, second-party software that changes the alarm color scheme may also have been installed. Furthermore, no provision exists for the color blind or to provide work stations with only black ink on alarm printouts. These inconsistencies and confusing setups could inadvertently cause a misinterpretation of the alarm, resulting in the potential release of a radiological hazard into a sovereign country. These issues are discussed, and a proposed solution is offered.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High speed, multi-channel, user programmable digital data acquisition system.

As applications for radiation detection become more demanding, and in turn improvements are made in the technology of radiation detection, there is a need for high speed digital detector readout electronics matching these improvements. Specifically, full control over the on-line processing resources of modern digital electronics is desirable so that researchers can develop custom algorithms for special applications.In the proposed effort, the 500 MHz digital readout electronics previously developed by our company will be redesigned to allow user access to the on-line processing resources. In Phase I, the division of online processing into vendor and user firmware sections has been studied on existing hardware. In Phase II, the hardware will be upgraded to better facilitate the division, and the firmware will be restructured into a robust vendor logic block (providing standard functions such as host I/O, on-board memory I/O, energy computation, MCA spectra, timestamps, waveform capture, run statistics, and triggering and timing) and a user logic block for custom algorithms (with templates and examples for frequently used functions). Investigating several options to divide online processing, it was determined that the most promising approach is to “partition” a single FPGA integrated circuit into a vendor and user section, which is supported in newer devices. The analog front end of the existing electronics proved suitable for most applications, in particular high rate measurements with germanium detectors. The design architecture for new electronics was developed, combining one of the new FPGA device with the analog front end.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of quantum dot materials for infrared cameras (Final CRADA Report)

The aim of this project was to develop scalable methods to produce infrared (IR) mercury telluride (HgTe) colloidal quantum dot (CQD) thin films and demonstrate their utility in a proof-of-concept monolithic SWIR focal plane array (FPA). These objectives were accomplished by scaling up the HgTe CQD synthesis, characterizing physical and electrical properties of HgTe CQDs, evaluating solution-processed coating methods for quality and efficiency, and developing a process flow to integrate HgTe CQDs with commercial-off-the-shelf silicon CMOS readout circuits by solution-processed coating to produce monolithic FPAs. The FPA is the image sensor in an infrared imaging system responsible for detecting and processing reflected or emitted light into an infrared image of the scene under observation. The quality of the image is determined by the sensitivity and resolution of the image sensor in the system. Higher resolution IR FPAs enable higher throughput in manufacturing quality assurance, wider field of view for autonomous navigation, and longer range surveillance for defense.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Search for WW and WZ production in lepton, neutrino plus jets final states at CDF Run II and Silicon module production and detector control system for the ATLAS SemiConductor Tracker

In the first part of this work, we present a search for WW and WZ production in charged lepton, neutrino plus jets final states produced in p$\bar{p}$ collisions with √s = 1.96 TeV at the Fermilab Tevatron, using 1.2 fb -1 of data accumulated with the CDF II detector. This channel is yet to be observed in hadron colliders due to the large singleWplus jets background. However, this decay mode has a much larger branching fraction than the cleaner fully leptonic mode making it more sensitive to anomalous triple gauge couplings that manifest themselves at higher transverse W momentum. Because the final state is topologically similar to associated production of a Higgs boson with a W, the techniques developed in this analysis are also applicable in that search. An Artificial Neural Network has been used for the event selection optimization. The theoretical prediction for the cross section is σ WW/WZ theory x Br(W → ℓv; W/Z → jj) = 2.09 ± 0.14 pb. They measured N Signal = 410 ± 212(stat) ± 102(sys) signal events that correspond to a cross section σ WW/WZ x Br(W → ℓv; W/Z → jj) = 1.47 ± 0.77(stat) ± 0.38(sys) pb. The 95% CL upper limit to the cross section is estimated to be σ x Br(W → ℓv; W/Z → jj) < 2.88 pb. The second part of the present work is technical and concerns the ATLAS SemiConductor Tracker (SCT) assembly phase. Although technical, the work in the SCT assembly phase is of prime importance for the good performance of the detector during data taking. The production at the University of Geneva of approximately one third of the silicon microstrip end-cap modules is presented. This collaborative effort of the university of Geneva group that lasted two years, resulted in 655 produced modules, 97% of which were good modules, constructed within the mechanical and electrical specifications and delivered in the SCT collaboration for assembly on the end-cap disks. The SCT end-caps and barrels consist of 4088 silicon modules, with a total of 6.3 million readout channels. The coherent and safe operation of the SCT during commissioning and subsequent operation is the essential task of the Detector Control System (DCS). The main building blocks of the DCS are the cooling system, the power supplies and the environmental system. The DCS has been initially developed for the SCT assembly phase and this system is described in the present work. Particular emphasis is given in the environmental hardware and software components, that were my major contributions. Results from the DCS testing during the assembly phase are also reported.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Automated drug identification system

System speeds up analysis of blood and urine and is capable of identifying 100 commonly abused drugs. System includes computer that controls entire analytical process by ordering various steps in specific sequences. Computer processes data output and has readout of identified drugs.

Campen, C. F., Jr.↗

Hybrid temperature-monitoring circuit

Hybrid circuit developed for use in hand-held vital signs monitor converts resistance of thermistor probe to 3 1/2 digit BCD (binary-coded-decimal) temperature readout. If used alone circuit can form 'stand alone' temperature monitor or can transmit temperature data via telemetry to data acquisition systems.

Rinard, G. A.↗

Micro-X Sounding Rocket: Transitioning from First Flight to a Dark Matter Configuration

The Micro-X sounding rocket flew for the first time on July 22, 2018, becoming the first program to fly Transition-Edge Sensors and multiplexing SQUID readout electronics in space. While a rocket pointing failure led to no time on-target, the success of the flight systems was demonstrated. The successful flight operation of the instrument puts the program in a position to modify the payload for indirect galactic dark matter searches. The payload modifications are motivated by the science requirements of this observation. Micro-X can achieve world-leading sensitivity in the keV regime with a single flight. Dark matter sensitivity projections have been updated to include recent observations and the expected sensitivity of Micro-X to these observed fluxes. If a signal is seen (as seen in the X-ray satellites), Micro-X can differentiate an atomic line from a dark matter signature.

J. S. Adams↗

The Upgrade Path from Legacy VME to VXS Dual Star Connectivity for Large Scale Data Acquisition and Trigger Systems

New instrumentation modules have been designed by Jefferson Lab and to take advantage of the higher performance and elegant backplane connectivity of the VITA 41 VXS standard. These new modules are required to meet the 200KHz trigger rates envisioned for the 12GeV experimental program. Upgrading legacy VME designs to the high speed gigabit serial extensions that VXS offers, comes with significant challenges, including electronic engineering design, plus firmware and software development issues. This paper will detail our system design approach including the critical system requirement stages, and explain the pipeline design techniques and selection criteria for the FPGA that require embedded Gigabit serial transceivers. The entire trigger system is synchronous and operates at 250MHz clock with synchronization signals, and the global trigger signals distributed to each front end readout crate via the second switch slot in the 21 slot, dual star VXS backplane. The readout of the buffered detector signals relies on 2eSST over the standard VME64x path at >200MB/s. We have achieved 20Gb/s transfer rate of trigger information within one VXS crate and will present results using production modules in a two crate test configuration with both VXS crates fully populated. The VXS trigger modules that reside in the front end crates, will be ready for production orders by the end of the 2011 fiscal year. VXS Global trigger modules are in the design stage now, and will be complete to meet the installation schedule for the 12GeV Physics program.

99 GENERAL AND MISCELLANEOUS↗

Operationally induced preferred basis in unitary quantum mechanics

The preferred-basis problem and the definite-outcome aspect of the measurement problem persist even if the detector is modeled unitarily, because experimental data are necessarily represented in a Boolean event algebra of mutually exclusive records whereas the theoretical description is naturally formulated in a noncommutative operator algebra with continuous unitary symmetry. This change of mathematical type constitutes the core of the 'cut': a structurally necessary interface from group-based kinematics to set-based counting. In the presented view the basis relevant for recorded outcomes is not determined by the system Hamiltonian alone; it is induced by the measurement mapping, i.e., by the detector channel together with the coarse-grained readout that defines an instrument. The probabilistic mapping is anchored in symmetry and measure theory: by Gleason-type uniqueness (Gleason for projections in $d>2$ and Busch's extension for Positive Operator-Valued Measures (POVMs) including $d=2$), the trace rule is the unique probability measure consistent with additivity over exclusive events and basis-independence of the unitary sector. A compact qubit--pointer model yields an induced unsharp POVM $E_\pm=\tfrac12(\id\pm η\,σ_z)$ with $η$ fixed by pointer resolution, displaying explicitly how the detector induces the relevant basis. Finally, nested-observer paradoxes are tightened into a non-composability lemma: joint assignment of outcome propositions is obstructed unless a joint instrument exists. This relocates the origin of randomness to the stochasticity of the transition rules.

Pronskikh, Vitaly [Fermilab] (ORCID:00000002518174↗

A luminescent nanocrystal stress gauge

Microscale mechanical forces can determine important outcomes ranging from the site of material fracture to stem cell fate. However, local stresses in a vast majority of systems cannot be measured due to the limitations of current techniques. In this work, we present the design and implementation of the CdSe/CdS core/shell tetrapod nanocrystal, a local stress sensor with bright luminescence readout. We calibrate the tetrapod luminescence response to stress, and use the luminescence signal to report the spatial distribution of local stresses in single polyester fibers under uniaxial strain. The bright stress-dependent emission of the tetrapod, its nanoscale size, and its colloidal nature provide a unique tool that may be incorporated into a variety of micromechanical systems including materials and biological samples to quantify local stresses with high spatial resolution.

36 MATERIALS SCIENCE↗

WE-G-17A-03: MRIgRT: Quantification of Organ Motion

Purpose: To develop an MRI-based methodology and tools required for the quantification of organ motion on a dedicated MRI-guided radiotherapy system. A three-room facility, consisting of a TrueBeam 6X linac vault, a 1.5T MR suite and a brachytherapy interventional room, is currently under commissioning at our institution. The MR scanner can move and image in either room for diagnostic and treatment guidance purposes. Methods: A multi-imaging modality (MR, kV) phantom, featuring programmable 3D simple and complex motion trajectories, was used for the validation of several image sorting algorithms. The testing was performed on MRI (e.g. TrueFISP, TurboFLASH), 4D CT and 4D CBCT. The image sorting techniques were based on a) direct image pixel manipulation into columns or rows, b) single and aggregated pixel data tracking and c) using computer vision techniques for global pixel analysis. Subsequently, the motion phantom and sorting algorithms were utilized for commissioning of MR fast imaging techniques for 2D-cine and 4D data rendering. MR imaging protocols were optimized (e.g. readout gradient strength vs. SNR) to minimize the presence of susceptibility-induced distortions, which were reported through phantom experiments and numerical simulations. The system-related distortions were also quantified (dedicated field phantom) and treated as systematic shifts where relevant. Results: Image sorting algorithms were validated for specific MR-based applications such as quantification of organ motion, local data sampling, and 4D MRI for pre-RT delivery with accuracy better than the raw image pixel size (e.g. 1 mm). MR fast imaging sequences were commissioning and imaging strategies were developed to mitigate spatial artifacts with minimal penalty on the image spatial and temporal sampling. Workflows (e.g. liver) were optimized to include the new motion quantification tools for RT planning and daily patient setup verification. Conclusion: Comprehensive methods were developed and validated for the quantification of organ motion with applications in MRI-guided RT.

60 APPLIED LIFE SCIENCES↗

High Speed, Multi-Channel, Thermal Instrument Development in Support of HyspIRI-TIR

The Jet Propulsion Laboratory is currently developing an end-to-end instrument which will provide a proof of concept prototype vehicle for a high data rate, multi-channel, thermal instrument in support of the Hyperspectral Infrared Imager (HyspIRI)-Thermal Infrared (TIR) space mission. HyspIRI mission was recommended by the National Research Council Decadal Survey (DS). The HyspIRI mission includes a visible shortwave infrared (SWIR) pushboom spectrometer and a multispectral whiskbroom thermal infrared (TIR) imager. The prototype testbed instrument addressed in this effort will only support the TIR. Data from the HyspIRI mission will be used to address key science questions related to the Solid Earth and Carbon Cycle and Ecosystems focus areas of the NASA Science Mission Directorate. Current designs for the HyspIRI-TIR space borne imager utilize eight spectral bands delineated with filters. The system will have 60m ground resolution, 200mK NEDT, 0.5C absolute temperature resolution with a 5-day repeat from LEO orbit. The prototype instrument will use mercury cadmium telluride (MCT) technology at the focal plane array in time delay integration mode. A custom read out integrated circuit (ROIC) will provide the high speed readout hence high data rates needed for the 5 day repeat. The current HyspIRI requirements dictate a ground knowledge measurement of 30m, so the prototype instrument will tackle this problem with a newly developed interferometeric metrology system. This will provide an absolute measurement of the scanning mirror to an order of magnitude better than conventional optical encoders. This will minimize the reliance on ground control points hence minimizing postprocessing (e.g. geo-rectification computations).

Multi-spectral↗

A land-surface testbed for EOSDIS

We propose to develop an on-line data distribution and interactive display system for the collection, archival, distribution and analysis of operational weather satellite data for applications in land surface studies. A 1,000 sq km scene of the western U.S. (centered on the Colorado Rockies) will be extracted from Advanced Very High Resolution Radiometer (AVHRR) imagery collected from morning and afternoon passes of the NOAA polar-orbiters at the direct readout stations operated by CU/CCAR. All five channels of these AVHRR data will be navigated and map registered at CU/CCAR and then be transferred to NCAR for storage in an on-line data system. Software will also be available at NCAR to process and navigate the raw AVHRR data as needed. A display workstation software, based on a Macintosh II computer, will be developed that will display and further process the AVHRR data for studies of vegetation monitoring and snowpack assessment. Various options of presently used techniques for both vegetation and snowpack monitoring will be implemented in the workstation software to provide the individual investigator with the freedom to interact with the satellite image data. The display software will be freely distributed online to interested investigators and the AVHRR data will be made available on-line to anyone interested. In addition, potential users will be sought out and connected to the on-line data archive. This experiment with an active on-line archive and interactive analysis systems will provide experience with a small scale EOSDIS.

Emery, William↗

A land-surface testbed for EOSDIS

We propose to develop an on-line data distribution and interactive display system for the collection, archival, distribution and analysis of operational weather satellite data for applications in land surface studies. A 1,000 square km scene of the western U.S. (centered on the Colorado Rockies) will be extracted from Advanced Very High Resolution Radiometer (AVHRR) imagery collected from morning and afternoon passes of the NOAA polar-orbiters at the direct readout stations operated by CU/CCAR. All five channels of these AVHRR data will be navigated and map registered at CU/CCAR and then be transferred to NCAR for storage in an on-line data system. Software will also be available at NCAR to process and navigate the raw AVHRR data as needed. A display workstation software, based on a Macintosh II computer, will be developed that will display and further process the AVHRR data for studies of vegetation monitoring and snowpack assessment. Various options of presently used techniques for both vegetation and snowpack monitoring will be implemented in the workstation software to provide the individual investigator with the freedom to interact with the satellite image data. The display software will be freely distrributed online to interested investigators, and the AVHRR data will be made available on-line to anyone interested. In addition, potential users will be sought out and connected to the on-line data archive. This experiment with an active on-line archive and interactive analysis systems will provide experience with a small scale EOSDIS.

Emery, William↗

The electronics and data acquisition system for the DarkSide-50 veto detectors

DarkSide-50 is a detector for dark matter candidates in the form of weakly interacting massive particles. It utilizes a liquid argon time projection chamber for the inner main detector, surrounded by a liquid scintillator veto (LSV) and a water Cherenkov veto detector (WCV). The LSV and WCV act as the neutron and cosmogenic muon veto detectors for DarkSide-50. This paper describes the electronics and data acquisition system used for these two detectors. The system is made of a custom built front end electronics and commercial National Instruments high speed digitizers. The front end electronics, the DAQ, and the trigger system have been used to acquire data in the form of zero-suppressed waveform samples from the 110 PMTs of the LSV and the 80 PMTs of the WCV. The veto DAQ system has proven its performance and reliability. This electronics and DAQ system can be scaled and used as it is for the veto of the next generation DarkSide-20k detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗