Search NASA⌕ Search

SEARCH · Search NASA

Results for “software performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

OSiRIS: a distributed Ceph deployment using software defined networking for multi-institutional research

We report on the first year of the OSiRIS project (NSF Award #1541335, UM, IU, MSU and WSU) which is targeting the creation of a distributed Ceph storage infrastructure coupled together with software-defined networking to provide high-performance access for wellconnected locations on any participating campus. The projects goal is to provide a single scalable, distributed storage infrastructure that allows researchers at each campus to read, write, manage and share data directly from their own computing locations. The NSF CC*DNI DIBBS program which funded OSiRIS is seeking solutions to the challenges of multi-institutional collaborations involving large amounts of data and we are exploring the creative use of Ceph and networking to address those challenges. While OSiRIS will eventually be serving a broad range of science domains, its first adopter will be the LHC ATLAS detector project via the ATLAS Great Lakes Tier-2 (AGLT2) jointly located at the University of Michigan and Michigan State University. Part of our presentation will cover how ATLAS is using the OSiRIS infrastructure and our experiences integrating our first user community. The presentation will also review the motivations for and goals of the project, the technical details of the OSiRIS infrastructure, the challenges in providing such an infrastructure, and the technical choices made to address those challenges. We will conclude with our plans for the remaining 4 years of the project and our vision for what we hope to deliver by the projects end.

97 MATHEMATICS AND COMPUTING↗

Scintillation Light Detection System in LArIAT

The LArIAT experiment is currently taking data at Fermilab using a Liquid Argon TPC, with the aim of studying particle interactions and characterizing detector response for neutrino detectors using argon. In parallel, it serves as a test-bench to develop and evaluate the performance of the simulation, reconstruction, and analysis software used in LAr neutrino experiments. LArIAT also takes advantage of the scintillating capabilities of liquid argon and will evaluate the feasibility of using the light signal to determine calorimetric information and particle identification. To test this possibility, a scintillation light detection system consisting of high Quantum Efficiency (QE) PMT and Silicon Photomultiplier (SiPM) devices is installed in the cryostat, viewing the interior of the TPC. Light collection efficiency is maximized by means of lining the walls with reflector foils covered by a wavelength shifter layer. Collecting the light reflected at the boundaries of the active volume greatly improves also the uniformity of the light yield. Presented here are initial results of the LArIAT light detection system calibration together with the preliminary results of the dedicated simulation and its application in future LAr TPC experiments

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fundamental limit of jet tagging

Identifying the origin of high-energy hadronic jets (jet tagging) has been a critical benchmark problem for machine learning in particle physics. Jets are ubiquitous at colliders and are complex objects that serve as prototypical examples of collections of particles to be categorized. Over the last decade, machine learning-based classifiers have replaced classical observables as the state of the art in jet tagging. Increasingly complex machine learning models are leading to increasingly more effective tagger performance. Our goal is to address the question of convergence—are we getting close to the fundamental limit on jet tagging or is there still potential for computational, statistical, and physical insights for further improvements? We address this question using state-of-the-art generative models to create a realistic, synthetic dataset with a known jet tagging optimum. Various state-of-the-art taggers are deployed on this dataset, showing that there is a significant gap between their performance and the optimum. Our dataset and software are made public to provide a benchmark task for future developments in jet tagging and other areas of particle physics.

Artificial intelligence↗

Time-dependent wave front propagation simulation of a hard x-ray split-and-delay unit: Towards a measurement of the temporal coherence properties of x-ray free electron lasers

For the European x-ray free electron laser (XFEL) a split-and-delay unit based on geometrical wavefront beam splitting and multilayer mirrors is built which covers the range of photon energies from 5 keV up to 20 keV. Maximum delays between Δτ = ±2.5 ps at hν=20 keV and up to Δτ = ±23 ps at hν = 5 keV will be possible. Time-dependent wave-optics simulations have been performed by means of Synchrotron Radiation Workshop software for XFEL pulses at hν = 5 keV. The XFEL radiation was simulated using results of time-dependent simulations applying the self-amplified spontaneous emission code FAST. Main features of the optical layout, including diffraction on the beam splitter edge and optics imperfections measured with a nanometer optic component measuring machine slope measuring profiler, were taken into account. The impact of these effects on the characterization of the temporal properties of XFEL pulses is analyzed. An approach based on fast Fourier transformation allows for the evaluation of the temporal coherence despite large wavefront distortions caused by the optics imperfections. In this manner, the fringes resulting from time-dependent two-beam interference can be filtered and evaluated yielding a coherence time of τ c = 0.187 fs (HWHM) for real, nonperfect mirrors, while for ideal mirrors a coherence time of τ c = 0.191 fs (HWHM) is expected.

36 MATERIALS SCIENCE↗

Fast-scanning high-flux microprobe for biological X-ray fluorescence microscopy and microXAS

There is a growing interest in the biomedical community in obtaining information concerning the distribution and local chemical environment of metals in tissues and cells. Recently, biological X-ray fluorescence microscopy (XFM) has emerged as the tool of choice to address these questions. A fast-scanning high-flux X-ray microprobe, built around a recently commissioned pair of 200 mm-long Rh-coated silicon Kirkpatrick-Baez mirrors, has been constructed at BioCAT beamline 18ID at the Advanced Photon Source. The new optical system delivers a flux of 1.3 x 10{sup 12} photons s{sup -1} into a minimum focal spot size of {approx}3-5 {micro}m FWHM. A set of Si drift detectors and bent Laue crystal analyzers may be used in combination with standard ionization chambers for X-ray fluorescence measurements. BioCAT's scanning software allows fast continuous scans to be performed while acquiring and storing full multichannel analyzer spectra per pixel on-the-fly with minimal overhead time (<20 ms per pixel). Together, the high-flux X-ray microbeam and the rapid-scanning capabilities of the BioCAT beamline allow the collection of XFM and micro X-ray absorption spectroscopy (microXAS) measurements from as many as 48 tissue sections per day. This paper reports the commissioning results of the new instrument with representative XFM and microXAS results from tissue samples.

43 PARTICLE ACCELERATORS↗

A Framework for Integrating Quantum Simulation and High Performance Computing

Scientific applications are starting to explore the viability of quantum computing. This exploration typically begins with quantum simulations that can run on existing classical platforms, albeit without the performance advantages of real quantum resources. In the context of high-performance computing (HPC), the incorporation of simulation software can often take advantage of the powerful resources to help scale-up the simulation size. The configuration, installation and operation of these quantum simulation packages on HPC resources can often be rather daunting and increases friction for experimentation by scientific application developers. We describe a framework to help streamline access to quantum simulation software running on HPC resources. This includes an interface for circuit-based quantum computing tasks, as well as the necessary resource management infrastructure to make effective use of the underlying HPC resources. The primary contributions of this work include a classification of different usage models for quantum simulation in an HPC context, a review of the software architecture for our approach and a detailed description of the prototype implementation to experiment with these ideas using two different simulators (TNQVM & NWQ-Sim). We include initial experimental results running on the Frontier supercomputer at the Oak Ridge Leadership Computing Facility (OLCF) using a synthetic workload generated via the SupermarQ quantum benchmarking framework.

Shehata, Amir [ORNL] (ORCID:0000000224531426)↗

Physical characteristics of GE Senographe Essential and DS digital mammography detectors

The purpose of this study was to investigate physical characteristics of two full field digital mammography (FFDM) systems (GE Senographe Essential and DS). Both are indirect conversion (x ray to light) a-Si flat panels coupled with a CsI(Tl) scintillator. The examined systems have the same pixel size (100 {mu}m) but a different field of view: a conventional size 23x19.2 cm{sup 2} and a large field 24x30.7 cm{sup 2}, specifically designed to image large breasts. In the GE Senographe Essential model relevant improvements in flat panel design were implemented and new deposition tools for metal, a-Si, and CsI(Tl) were introduced by GE. These changes in detector design are expected to be beneficial for advanced applications such as breast tomosynthesis. The presampling modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE) were measured for a wide range of exposure (25-240 {mu}Gy) with a RQA-M2 technique (28 kVp with a Mo/Mo target/filter combination and 2 mm of additional aluminum filtration). At 1, 2, and at 4 lp/mm MTF is equal to 0.9, 0.76, and 0.46 for the conventional field detector and to 0.85, 0.59, and 0.24 for the large field detector. The latter detector exhibits an improved NNPS due to a lower electronic noise and a better DQE that reaches 60%. In addition a contrast-detail analysis was performed with CDMAM 3.4 phantom and CDCOM software: GE Senographe DS showed statistically significant poorer detection ability in comparison with the GE Senographe Essential. These results could have been expected, at least qualitatively, considering the relative DQE of the two systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three dosimetry models of lipoma arborescens treated by {sup 90}Y synovectomy

Purpose: Lipoma arborescens (LA) is a benign intra-articular lipomatous proliferation of the synovial membrane. This extremely rare condition has previously been treated by intra-articular{sup 90}Y radiosynoviorthesis but dosimetry literature on this form of radionuclide therapy is nonexistent. The authors detail methodology for successful treatment of LA and provide for the first time estimates of radiation dosimetry. The authors also analyze the biodistribution of the radiopharmaceutical over the course of the patient's treatment through sequential imaging. Methods: A patient with bilateral LA underwent intracavity injection of{sup 90}Y citrate colloid to the right and left knee joint spaces (181 and 198 MBq, respectively). SPECT/CT datasets were acquired over 9 days to quantify the biodistribution and kinetics of the radiopharmaceutical. Radiation dosimetry was performed using the MIRD schema (through OLINDA software), a custom voxel-based method, and a direct Monte Carlo calculation (OEDIPE). Results: Follow-up MRI showed marked reduction in LA size in both knees. Mean absorbed doses to the LA were 21.2 ± 0.8 and 42.9 ± 2.3 Gy using OLINDA, 8.1 ± 0.3 and 16.7 ± 0.5 Gy using voxel based methodology, and 8.2 ± 0.3 and 15.7 ± 0.5 Gy for OEDIPE in the right and left LA, respectively. Distribution of the radiopharmaceutical within the joint space alters over the imaging period, with less than 1% of the remaining activity having moved posteriorly in the knee cavity. No uptake was detected outside of the joint space after assessment with whole-body scintigraphy. Conclusions: An activity of approximately 185 MBq successfully relieved clinical symptoms of LA. There was good correlation between direct Monte Carlo and voxel based techniques, but OLINDA was shown to overestimate the absorbed dose to the tumor. Accurate dosimetry may help select an activity more tailored to the specific size and location of the LA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-303-06: Treatment Planning Study for Non-Invasive Cardiac Arrhythmia Ablation with Scanned Carbon Ions in An Animal Model

Purpose: Scanned carbon ion beams might offer a non-invasive alternative treatment for cardiac arrhythmia, which are a major health-burden. We studied the feasibility of this procedure in an animal model. The underlying treatment planning and motion mitigation strategies will be presented. Methods: The study was carried out in 15 pigs, randomly distributed to 3 target groups: atrioventricular node (AVN, 8 animals with 25, 40, and 55 Gy target dose), left ventricular free-wall (LV, 4 animals with 40 Gy) and superior pulmonary vein (SPV, 3 animals with 40 Gy). Breathing motion was suppressed by repeated enforced breathholds at end exhale. Cardiac motion was mitigated by an inhomogeneous rescanning scheme with up to 15 rescans. The treatment planning was performed using the GSI in-house software TRiP4D on cardiac-gated 4DCTs, applying a range-considering ITV based on an extended CTV. For AVN and SPV isotropic 5 mm margins were applied to the CTV, while for the LV 2mm+2% range margins were used. The opposing fields for AVN and LV targets were optimized independently (SFUD), while SPV treatments were optimized as IMPT deliveries, including dose restrictions to the radiosensitive AVN. Results: Median value of D{sub 95} over all rescanning simulations was 99.1% (AVN), 98.0% (SPV) and 98.3% (LV) for the CTV and 94.7% (AVN) and 92.7% (SPV) for the PTV, respectively. The median D{sub 5}-D{sub 95} was improved with rescanning compared to unmitigated delivery from 13.3 to 6.5% (CTV) and from 23.4 to 11.6% (PTV). ICRP dose limits for aorta, trachea, esophagus and skin were respected. The maximal dose in the coronary arteries was limited to 30 Gy. Conclusion: We demonstrated the feasibility of a homogeneous dose delivery to different cardiac structures in a porcine model using a time-optimized inhomogeneous rescanning scheme. The presented treatment planning strategies were applied in a pig study with the analysis ongoing. Funding: This work was supported in part by the Helmholtz Association, the American Heart Association Midwest Affiliate Postdoctoral Fellowship Grant, the Mayo Clinic Foundation, and the Goldsmith Foundation.

60 APPLIED LIFE SCIENCES↗

SU-E-T-164: Characterization of Breast Deformation During Accuboost TM Treatment

Purpose: During treatment using AccuboostTM (Advanced Radiation Therapy, Tyngsboro, MA) applicators the breast is compressed between two paddles in order to immobilize it. This causes the breast tissue to expand. The purpose of this study was to analyze the nature of this deformation. Methods: CT scans of a breast phantom (Computerized Imaging Reference Systems, Norfolk, VA) were acquired at different compressions in the cranial-caudal (CC) direction. These were performed by placing the phantom between two plates whose position is controlled by a manual crank. The phantom masses were contoured in order to simulate the clips placed after surgery. For all scans the mean distance between the masses was computed. Additionally, deformable registration was performed between two scans using the Velocity software (Varian Medical Systems, Palo Alto, CA) to assess the shifts of each of these masses. Results: As the compression increases so does the average distance between the masses. The relationship between deformation and compression is not linear. Additionally, the largest displacements are in the direction of compression. The mean shift is 1.8mm. The shifts in the RT-LT direction and ANT-POST direction are 1.1 mm and 0.7 mm respectively Conclusion: When treating patients the clips shift their position as a Result of the plate compression. For CC compressions this is not a problem if they shift their position primarily in the superior-inferior direction. The problem of not being able to cover all clips (target area) can arise when they shift position on a plane perpendicular to the patient. For clips which are already near the chest wall, care should be exercised not to compress the breast in such a way as to move those clips out of the treatable area.These preliminary results show a larger shift in the RT-LT direction than the ANT-POST one. Further research will seek to either confirm or infirm this.

60 APPLIED LIFE SCIENCES↗

TU-H-BRA-04: A Novel Superconducting Magnet Design for Optimized Patient Access and Minimal SSD for Use in a Linac-MR Hybrid

Purpose: A prototype rotating hybrid MR imaging system and linac has been developed to allow for simultaneous imaging and radiation delivery parallel to B{sub 0}. However, the design of a compact magnet capable of rotation in a small vault with sufficient patient access and a typical clinical source-to-surface distance (SSD) is challenging. This work presents a novel superconducting magnet design that allows for a reduced SSD and ample patient access by moving the superconducting coils to the side of the yoke. The yoke and pole-plate structures are shaped to direct the magnetic flux appropriately. Methods: The surface of the pole plate for the magnet assembly is optimized. The magnetic field calculations required in this work are performed with the 3D finite element method software package Opera-3D. Each tentative design strategy is virtually modeled in this software package and externally controlled by MATLAB, with its key geometries defined as variables. The particle swarm optimization algorithm is used to optimize the variables subject to the minimization of a cost function. At each iteration, Opera-3D will solve the magnetic field solution over a field-of-view suitable for MR imaging and the degree of field uniformity will be assessed to calculate the value of the cost function associated with that iteration. Results: An optimized magnet assembly that generates a homogenous 0.2T magnetic field over an ellipsoid with large axis of 30 cm and small axes of 20 cm is obtained. Conclusion: The distinct features of this model are the minimal distance between the yoke’s top and the isocentre and the improved patient access. On the other hand, having homogeneity over an ellipsoid give us a larger field-of-view, essential for geometric accuracy of the MRI system. The increase of B{sub 0} from 0.2T in the present model to 0.5T is the subject of future work. Funding Sources: Alberta Innovates - Health Solutions (AIHS)| Disclosure and Conflict of Interest: B. Gino Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta biplanar linac MR for commercialization).

60 APPLIED LIFE SCIENCES↗

Full event interpretation with machine-learning-based particle-flow reconstruction in the CMS detector

The particle-flow (PF) algorithm constructs a global description of each particle collision by producing a comprehensive list of final-state particles, and is central to event reconstruction in the CMS experiment at the CERN LHC. The existing PF implementation relies on physics-motivated heuristics and assumptions that can be replaced by machine-learning (ML) models trained directly on simulated data and naturally suited to modern graphics processing units (GPUs). A state-of-the-art ML-based PF (MLPF) reconstruction algorithm, implemented within the CMS software framework, is presented. The MLPF algorithm performs a learnable full-event reconstruction on GPUs, generalizes across detector conditions and collision energies, and replaces multiple modular reconstruction steps with a single unified model. Physics performance comparable to standard PF reconstruction is achieved in both simulation and data, with improved jet energy resolution and inference time. In simulated top quark-antiquark events under LHC Run-3 (2023-2024) conditions, the jet energy resolution improves by 10-20% for jets with transverse momentum between 30-100 GeV. Inference time is evaluated using simulated multijet events, with a median of $20\,\hbox {ms}$ per event on an Nvidia L4 GPU, compared to approximately $110\,\hbox {ms}$ for the standard CMS PF reconstruction.

Hayrapetyan, Aram [Yerevan Phys. Inst.]↗

lalibe v1.0

This is top-level lattice QCD code developed by employees at LBNL and LLNL. It currently compiles on top of the USQCD Chroma software stack. This code contains high-performance routines that are used in our research, and we intend to release this code publicly to ensure reproducibility and to meet our obligations for complying with the DOE Digital Data rules.

Walker-Loud, Andre↗

MEUMAPPS (Microstructure Evolution Using Massively Parallel Phase-field Simulations)

The software “MEUMAPPS” is a h high-performance computing code used to simulate microstructure evolution associated with diffusional solid-state transformations in structural alloys. Understanding microstructure evolution during thermo-mechanical processing of structural alloys is the first step towards designing and processing alloys for specific applications by meeting property requirements demanded by the application. In this instance, the code is an important component in predicting processing-structure linkages during additive manufacturing of structural alloys as a function of processing parameters and alloy composition used in an additive manufacturing process. The code provides a detailed three-dimensional distribution of different types of phases / constituents and their morphologies, as well as the compositions of these phases that make up the microstructure. The microstructure is simulated by solving the governing partial differential equations using a Fourier Spectral Method.

Radhakrishnan, Balasubram↗

Tool Gear Version 2.3

Tool Gear Version 2 is an expanded collection of programs and software libraries that form the infrastructure on which software tools may be built. The software tools help application developers understand the performance of the programs or help them find programming errors. Tool Gear includes components for gathering data from target programs, either through direct instrumentations or by parsing the output of third-party tools, transmitting the data to a database, organizing and storing the data, presenting it through a variety of graphical interfaces. Tool Gear is designed to be an extensible system, so users can manage a variety of data and create new ways to present it. Tool Gear is designed to work with both sequential and parallel programs on multiple computer platforms

Gyllenhaal, J.↗

NLR Data Processing Pipeline for MADIS [SWR-26-050]

The NLR Data Processing Pipeline for MADIS software package is for downloading, processing, and performing QA/QC on MADIS data. Designed to handle the following steps: 1) Download all MADIS data as compressed netcdf files for a given time period. 2) Unpack netcdf files into timeseries csvs for each coordinate within the given bounding box. 3) Process the csvs to filter according to quality control checks and convert variables to correct units. 4) Write processed csvs to a single nc file.

Benton, Brandon [National Laboratory of the Rockie↗

CBP Toolbox Version 2.0: Code Integration Enhancements

This report describes enhancements made to code integration aspects of the Cementitious Barriers Project (CBP) Toolbox as a result of development work performed at the Savannah River National Laboratory (SRNL) in collaboration with Vanderbilt University (VU) in the first half of fiscal year 2013. Code integration refers to the interfacing to standalone CBP partner codes, used to analyze the performance of cementitious materials, with the CBP Software Toolbox. The most significant enhancements are: 1) Improved graphical display of model results. 2) Improved error analysis and reporting. 3) Increase in the default maximum model mesh size from 301 to 501 nodes. 4) The ability to set the LeachXS/Orchestra simulation times through the GoldSim interface. These code interface enhancements have been included in a new release (Version 2.0) of the CBP Toolbox.

36 MATERIALS SCIENCE↗