Search NASA⌕ Search

SEARCH · Search NASA

Results for “Environmental Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Fuel economy and emissions testing of an RCCI series hybrid vehicle

In the current work, a series hybrid vehicle has been constructed that utilises a dual-fuel, reactivity controlled compression ignition (RCCI) engine. Full vehicle testing was conducted on chassis dynamometers over the US Environmental Protection Agency Federal Test Procedure, Highway Fuel Economy Test and US06 using RCCI combustion with commercially available gasoline and ultra-low sulphur diesel. Fuel economy and emissions data were recorded over the specified test cycles. Testing revealed that engine-out emissions were similar to steady-state dynamometer engine testing. However, tailpipe-out emissions saw a reduction of HC and CO during the HWFET of 98.5%. Fuel economy was lower than expected due to the higher drivetrain losses of the series hybrid drivetrain. Finally, simulated changes to the drivetrain showed that it may be possible to increase fuel economy significantly, while meeting EPA emissions standards.

33 ADVANCED PROPULSION SYSTEMS↗

Visual Sample Plan Version 7.0 User's Guide

User's guide for VSP 7.0 This user's guide describes Visual Sample Plan (VSP) Version 7.0 and provides instructions for using the software. VSP selects the appropriate number and location of environmental samples to ensure that the results of statistical tests performed to provide input to risk decisions have the required confidence and performance. VSP Version 7.0 provides sample-size equations or algorithms needed by specific statistical tests appropriate for specific environmental sampling objectives. It also provides data quality assessment and statistical analysis functions to support evaluation of the data and determine whether the data support decisions regarding sites suspected of contamination. The easy-to-use program is highly visual and graphic. VSP runs on personal computers with Microsoft Windows operating systems (XP, Vista, Windows 7, and Windows 8). Designed primarily for project managers and users without expertise in statistics, VSP is applicable to two- and three-dimensional populations to be sampled (e.g., rooms and buildings, surface soil, a defined layer of subsurface soil, water bodies, and other similar applications) for studies of environmental quality. VSP is also applicable for designing sampling plans for assessing chem/rad/bio threat and hazard identification within rooms and buildings, and for designing geophysical surveys for unexploded ordnance (UXO) identification.

97 MATHEMATICS AND COMPUTING↗

Condensation Particle Counter (CPC) Instrument Handbook

The Model 3772 CPC is a compact, rugged, and full-featured instrument that detects airborne particles down to 10 nm in diameter, at an aerosol flow rate of 1.0 lpm, over a concentration range from 0 to 1x104 #/cc. This CPC is ideally suited for applications without high concentration measurements, such as basic aerosol research, filter and air-cleaner testing, particle counter calibrations, environmental monitoring, mobile aerosol studies, particle shedding and component testing, and atmospheric and climate studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Outer planet Grand Tour missions photometry/polarimetry experiment critical components study

Work performed during this effort was limited to two primary areas of technical concern: optical design optimization, and sensor selection. An optical system concept was established, and various system components were evaluated through experimental test sequences. Photodetectors were investigated for the applicability in meeting OPGT requirements as constrained by the photometry/polarimetry team directives. The most promising (gallium arsenide PMT) was further experimentally tested to ascertain its behavior with respect to anticipated environmental conditions. Results of testing and summary of the preceding tradeoff study effort are presented.

Pellicori, S. F.↗

Measuring changes in environmental radiological background from construction of an advanced nuclear reactor testing facility

We present a method to survey and track changes in the environmental radiological background during the construction and operation of advanced nuclear reactor facilities. We discuss the results of two surveys of the environmental gamma-radiation background at NEXT Lab, an advanced nuclear reactor research facility on the campus of Abilene Christian University, prior to the introduction of radioactive material. In both surveys, the observed radiation dosage rates are low, with the highest rates at 15% of the average total radiation dosage rate for the United States. We observe ≈20% changes in the radiological background of the property in locations where the environment was changed by construction and ≈20% variations within the facilities correlated with variations in building materials.

Environment↗

Stratigraphic and structural controls on groundwater flow in an outcropping fossil fan delta: the case of Sant Llorenç del Munt range (NE Spain)

Hydrogeological models of mountain regions present the opportunity to understand the role of geological factors on groundwater resources. The effects of sedimentary facies and fracture distribution on groundwater flow and resource exploitation studied in the ancient fan delta of Sant Llorenç de Munt (central Catalonia, Spain) by integrating geological field observations (using sequence stratigraphy methods) and hydrogeological data (pumping tests, hydrochemistry and environmental isotopes). A comprehensive analysis of data portrays the massif as a single unit, constituted by different compartments determined by specific layers and sets of fractures. Two distinct flow systems—local and regional—are identified based on pumping test analysis as well as hydrochemical and isotopic data. Drawdown curves derived from pumping tests indicate that the behavior of the saturated layers, whose main porosity is given by the fracture network, corresponds to a confined aquifer. Pumping tests also reflect a double porosity within the system and the occurrence of impervious boundaries that support a compartmentalized model for the whole aquifer system. Hydrochemical data and associated spatial evolution show the result of water–rock interaction along the flow lines. Concentration of magnesium, derived from dolomite dissolution, is a tracer of the flow-path along distinct stratigraphic units. Water stable isotopes indicate that evaporation (near a 5% loss) occurs in a thick unsaturated zone within the massif before infiltration reaches the water table. The hydrogeological analysis of this outcropping system provides a methodology for the conceptualization of groundwater flow in similar buried systems where logging and hydrogeological information are scarce.

58 GEOSCIENCES↗

Submicron Sodium Banding in Cultured Planktic Foraminifera Shells

The calcite shells, or tests, of foraminifera provide a window into Earth history because they are well preserved in marine sediments and contain useful geochemical proxies for paleoceanography. Previous observations of diurnal heterogeneity in proxies like Mg/Ca demonstrate a complex relationship between environmental conditions and test composition. The definitive causes for this diurnal banding and the potential impact for proxy interpretation in systems other than Mg/Ca have yet to be determined. Here we use time-of-flight secondary ion mass spectrometry (ToF-SIMS), a chemical and isotope mapping technique with a spatial resolution of 300 nm, to show that Na banding is a consistent feature in the tests of cultured Orbulina universa, a species of planktic foraminifer. This banding occurs in two distinct forms: (1) sharp Na bands associated with embedded organic sheets and (2) regular, thicker, but lower-amplitude Na bands that are found throughout the test. In Orbulina bilobata, a morphotype of O. universa that develops a second partial spherical chamber attached to the primary sphere, we use the first type of banding to show that a second organic sheet is used as a template to form this second chamber. Thus, sodium banding links test geochemistry with foraminiferal growth models, allowing us to explain the pattern and timing of chamber formation as well as a specific type of geochemical banding in foraminifera. Furthermore, the magnitude, timing, and coherency between Na and Mg bands can help constrain mechanistic explanations for geochemical banding in foraminifera in general.

paleoclimate, Foraminifera, biomineralization, pal↗

A novel ozone sensor for various environmental applications

A small, lightweight, and fast-response ozone sensor for various environmental applications is described. At a flow rate of 100 l/min(-1) the ozone sensor has a response time of significantly better than 0.1 s with a detection limit lower than 100 pptv. The ozone sensor was successfully tested in various environmental applications, i.e. in measuring directly the vertical ozone flux onto agricultural land utilizing the eddy correlation or covariance technique and in monitoring horizontal and vertical ozone profiles in the troposphere and stratosphere.

Guesten, H.↗

Analysis of Monolith Cores from an Engineering Scale Demonstration of a Prospective Cast Stone Process

The primary disposition path of Low Activity Waste (LAW) at the DOE Hanford Site is vitrification. A cementitious waste form is one of the alternatives being considered for the supplemental immobilization of the LAW that will not be treated by the primary vitrification facility. Washington River Protection Solutions (WRPS) has been directed to generate and collect data on cementitious or pozzolanic waste forms such as Cast Stone. This report documents the coring and leach testing of monolithic samples cored from an engineering-scale demonstration (ES Demo) with non-radioactive simulants. The ES Demo was performed at SRNL in October of 2013 using the Scaled Continuous Processing Facility (SCPF) to fill an 8.5 ft. diameter x 3.25 ft. high container with simulated Cast Stone grout. The Cast Stone formulation was chosen from the previous screening tests. Legacy salt solution from previous Hanford salt waste testing was adjusted to correspond to the average LAW composition generated from the Hanford Tank Waste Operation Simulator (HTWOS). The dry blend materials, ordinary portland cement (OPC), Class F fly ash, and ground granulated blast furnace slag (GGBFS or BFS), were obtained from Lafarge North America in Pasco, WA. In 2014 core samples originally obtained approximately six months after filling the ES Demo were tested along with bench scale molded samples that were collected during the original pour. A latter set of core samples were obtained in late March of 2015, eighteen months after completion of the original ES Demo. Core samples were obtained using a 2” diameter x 11” long coring bit. The ES Demo was sampled in three different regions consisting of an outer ring, a middle ring and an inner core zone. Cores from these three lateral zones were further segregated into upper, middle and lower vertical segments. Monolithic core samples were tested using the Environmental Protection Agency (EPA) Method 1315, which is designed to provide mass transfer rates (release rates) of inorganic analytes contained in monolithic material under diffusion controlled release conditions as a function of leaching time. Compressive strength measurements and drying tests were also performed on the 2015 samples. Leachability indices reported are based on analyte concentrations determined from dissolution of the dried samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mercury Speciation via Diffusive Gradients Thin-Films Technology

Objectives: Develop and test various diffusive gradient in thin films (DGT) samplers for mercury - SRNL is developing reactive DGTS (rDGTs). Test chemistry to differentiate methylmercury from total and/or inorganic mercury in environmental samples. Fabricate and test rDGT samplers for deployment. Deploy the rDGTs in variable settings. Mercury is a persistent-bioaccumulative-toxic environmental pollutant. Mercury exists in different species such as elemental, inorganic, and methyl. Mercury speciation determine mercury behavior and toxicity. For example, methylmercury strongly accumulates in biota such as fish resulting in potential human health impacts. DGTs are innovative samplers to measure water concentration by diffusion and capture. Types of Hg DGTs used: Total Hg, Inorganic Hg, and Methyl Hg. Deployment Sites: Upper Three Runs, Lower Three Runs, Steele Creek, East Fork Poplar Creek (SRNL Sites), Horizons Creek, NOA Creek, Bruners Creek (ORNL Sites). DGT concentration estimates closely matched alternative measurements for soluble mercury at each Oak Ridge site - DGTs did not respond to particulate mercury. DGTs provide a representative measure for biota uptake since they are left out longer which allows for an average exposure concentration. DMA-80 provided an efficient and quick analysis. Variability in site location made a difference in Hg species. DGT preparations and sampling wasn't as quick and simple as microcolumn technology. Copper reagent degraded agarose gel - more work and cleaner data are needed to assess speciation in rDGTs. Future Work: Use cross-linked polyacrylamide for the collection layer for a stronger plastic. Make a copper diffusion layer without agarose. Test copper separation in lab using realistic stream conditions such as high organic carbon.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermal Cycle Reliability of PBGA/CCGA 717 I/Os

Status of thermal cycle test results for a nonfunctional daisy-chained peripheral ceramic column grid array (CCGA) and its plastic ball grid array (PBGA) version. both having 560 I/Os. were presented in last year's conference. Test results included environmental data for three different thermal cycle regimes (-55 C/125 C, -55 C/100 C, and -50 C /75 C). Update information on these - especially failure type for assemblies with high and low solder volumes-were presented. The thermal cycle test procedure followed those recommended IPC-9701 for tin-lead solder joint assemblies. Revision A of this specification covers guideline thermal cycle requirements for Pb-free solder joints. Some background information discussed during release of this specification with its current guideline recommendations were also presented. In a recent reliability investigation a fully populated CCGA with 717 I/Os was also considered for assembly reliability. evaluation. The functional package is a field-programmable gate array that has much higher processing power than its previous version. This new package is smaller in dimension, has no interposer, and has a thinner column wrapped with copper for reliability improvement. This paper will also present thermal cycle test results for this package assembly and its plastic version with 728 I/Os. both of which were exposed to three different cycle regimes. Two cycle profiles were those specified by IPC- 9701A for tin-lead, i.e. -55 to 100 C and -55 to 125 C and one was a cycle profile specified by Mil-Std-883, i.e.. -65 C/150 C which is generally used for ceramic hybrid packages. Per IPC-9701 A, test vehicles were built using daisy chain packages and were continuously monitored. The effects of many process and assembly variables-including corner staking commonly used for improving resistance to mechanical loading such as drop and vibration loads--were also considered as part of the test matrix. Optical photomicrographs were taken at various thermal cycle intervals to document damage progress and behavior. Representative samples of these along with cross-sectional photomicrographs at higher magnification taken by scanning electron microscopy (SEM) to determine crack propagation and failure analyses for packages are also presented.

staking↗

A Quantitative Evaluation of Dissolved Oxygen Instrumentation

The implications of the presence of dissolved oxygen in water are discussed in terms of its deleterious or beneficial effects, depending on the functional consequences to those affected, e.g., the industrialist, the oceanographer, and the ecologist. The paper is devoted primarily to an examination of the performance of five commercially available dissolved oxygen meters. The design of each is briefly reviewed and ease or difficulty of use in the field described. Specifically, the evaluation program treated a number of parameters and user considerations including an initial check and trial calibration for each instrument and a discussion of the measurement methodology employed. Detailed test results are given relating to the effects of primary power variation, water-flow sensitivity, response time, relative accuracy of dissolved-oxygen readout, temperature accuracy (for those instruments which included this feature), error and repeatability, stability, pressure and other environmental effects, and test results obtained in the field. Overall instrument performance is summarized comparatively by chart.

Pijanowski, Barbara S.↗

A Microphone Phased Array for Launch Acoustics Application

A new, portable, phased array of microphones is built at NASA Ames Research Center specifically for the harsh environment encountered in launch pads of rocket vehicles. It uses 70 rugged, piezo-electric, dynamic pressure sensors optimally distributed on a 10.5ft diameter open frame dome structure. The open frame is light yet robust to sustain the high wind load of typical seaside launch pads, and the blast and acoustic loads from the launch. A 200-ft long cable bundle carries the microphone signals to a weather-protected electronic cabinet containing the data acquisition system, computers, and other equipment. The array is equipped with an infra-red camera and a visible wavelength camera for imaging the launch site. The beamformed noise maps will be superimposed on the video footages collected by the cameras for correct identification of the noise sources. The array is tested with very loud noise sources to determine the beamforming ability. Multiple mathematical models, such as the conventional beamforming, orthogonal-functional beamforming, spectral element method etc. are used to determine the minimum spatial resolution of the sound sources that can be measured at different frequencies. Additionally, the array hardware is being tested for different environmental conditions and electro-magnetic compliance. The goal is to use the array for NASA’s Artemis/SLS vehicle that will be launched from a newly built Mobile Launch platform and a modified launch pad. Data from a couple of validation tests will be presented in this paper. The first test involves an outdoor setup where the array was placed on a crane at several different heights and distances from a pair of very loud noise sources. The second test from the static firing of the RS25 engines in an outdoor test stand.

Acoustics↗

X-43A Fluid and Environmental Systems: Ground and Flight Operation and Lessons Learned

The X-43A Hyper-X program demonstrated the first successful flights of an airframe integrated scramjet powered hypersonic vehicle. The X-43A vehicles established successive world records for jet-powered vehicles at speeds of Mach 7 and Mach 10. The X-43A vehicle is a subscale version of proposed hypersonic reconnaissance strike aircraft. Scaled down to a length of 12 ft (3.66 m), the lifting body design with high fineness ratio resulted in very small internal space available for fluid systems and their corresponding environmental conditioning systems. Safe testing and operation of the X-43A fluid and environmental systems was critical for mission success, not only for the safety of the flight crew in the NASA B-52B carrier aircraft, but also to maintain the reliability of vehicle systems while exposed to dynamics and hostile conditions encountered during the boost trajectory. The X-43A fluid and environmental systems successfully managed explosive, pyrophoric, inert, and very high pressure gases without incident. This report presents a summary of the checkout and flight validation of the X-43A fluid systems. The testing used for mission assurance is summarized. System performance during captive carry and launch flights is presented. The lessons learned are also discussed.

Vachon, Michael Jacob↗

Environmental Impact Analysis on the Hydraulic Fracture Test Site (HFTS)

Objective The Hydraulic Fracture Test Site (HFTS) provided a platform to test new extraction and production techniques and technologies to understand fracture geometry and increase the efficiency of shale hydrocarbon production. Eleven test wells were drilled in the Upper and Middle Wolfcamp formations, hydraulically fractured, and produced. Air quality, groundwater quality, and produced water chemistry and microbiology were monitored through the duration of the field experiment and one year into production. Methods BTEX, methane, VOCs, SOx, NOx, and PM 10 were measured 1,000 ft up-wind and 1,000 ft down-wind of the HFTS experiment before operations began, during hydraulic fracturing, flowback, and several months into production to evaluate operational impact on local air quality. The underlying Edward-Trinity Plateau aquifer was monitored using 5 groundwater wells within 2 miles of the HFTS pad; BTEX, methane, petroleum hydrocarbons, and a comprehensive suite of anions and metals were analyzed from samples taken before operations began, during hydraulic fracturing, flowback, and one year after production. Water produced from 3 of the 11 HFTS wells was analyzed for chemical and microbiological properties 1.5 years into production. Observations There was no significant impact to air quality from HFTS operations, although elevated BTEX concentrations were measured 1,000 ft. away from the well-pads during the flowback period. We detected no migration of hydrocarbon or fracture fluid chemical migration into the Edward-Trinity Plateau aquifer. Source waters used for hydraulic fracturing contained naturally occurring high concentrations (~500ppm) of sulfate. Rapid microbially induced corrosion was detected in several wells, leading to biocide dosing. Microbiological populations were significantly altered by biocide treatment, but still continued to increase in population size six months after application. Significance After hydraulic fracturing, detailed chemical and microbiological analysis provides evidence for microbiologicallymediated sub-surface transformations of supplied sulfate and organic carbon into sulfides. This report discusses air quality, water quality, and produced water analytical results for the HFTS experiment and further implications for the unconventional oil and gas industry.

Eisenlord, Sarah↗

Qualification tests and electrical measurements: Practice and problems

As part of the Flat-Plate Solar Array Project, 138 different module designs were subjected to qualification tests. Electrical measurements were subjected on well over a thousand modules representing more than 150 designs. From this experience, conclusions are drawn regarding results and problems, with discussion of the need for change or improvement. The qualification test sequence incuded application of environmental and electrical stresses to the module. With few exceptions, the tests have revealed defects necessitation of environmental and electrical stresses to the module. With few exceptions, the tests have revealed defects necessitating module design or process changes. However, the continued need for these tests may be questioned on the basis of technical and logistical factors. Technically, the current test sequence does not cover all design characteristics, does not include all field conditions and is not known to represent the desired 30-year module life. Logistically, the tests are time-consuming and costly, and there is a lack of, fully qualified independent test organizations. Alternatives to the current test program include simplification based on design specification and site environment, and/or the use of warranties or other commercial practices.

Smokler, M. I.↗

Energy Efficiency Package for Tenant Fit-Out: Laboratory Testing and Validation of Energy Savings and Indoor Environmental Quality

Approximately 40% of the total U.S. office floor space of 1.5 billion sq.m (16 billion sq.ft.) is leased space occupied by tenants. Tenant fit-out presents a key opportunity to incorporate energy efficiency within the real estate business cycle. We designed a package of energy efficiency measures tailored to the scope of a tenant fit-out. This tenant fit-out package (TFP) includes advanced lighting and heating, ventilating and air-conditioning (HVAC) controls as core measures, with ceiling fans, automated shading, and plug load controls as additional optional measures. We conducted laboratory testing of six configurations of the package to evaluate energy savings, indoor environmental quality, and identify installation, commissioning, and operational issues. Combined savings for HVAC, lighting, and plug loads ranged from 33–40%. Lighting savings ranged from 69–83%, and HVAC savings from 20–40%. The laboratory testing also revealed some minor but tractable challenges with installation and commissioning of HVAC controls. Overall, the results demonstrate that significant savings can be realized in existing office buildings by incorporating relatively low-risk, proven measures at the time of a tenant fit-out.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Qualification testing of secondary sterilizable silver-zinc cells for use in the Jupiter atmospheric entry probe

A series of qualification tests were run on the secondary, sterilizable silver oxide - zinc cell developed at the NASA Lewis Research Center to determine if the cell was capable of providing mission power requirements for the Jupiter atmospheric entry probe. The cells were tested for their ability to survive radiation at the levels predicted for the Jovian atmosphere with no loss of performance. Cell performance was evaluated under various temperature and loading conditions, and the cells were tested under various environmental conditions related to launch and to deceleration into the Jovian atmosphere. The cell performed acceptably except under the required loading at low temperatures. The cell was redesigned to improve low-temperature performance and energy density. The modified cells improved performance at all temperatures. Results of testing cells of both the original and modified designs are discussed.

Manzo, M. A.↗