Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION IMPLANTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

X-ray Diffuse Scattering near Bragg Relections for the Study of Clustered Defects in Crystalline Materials

The fundamental aspects of diffuse scattering from lattice defects within the coherent wave theory are reviewed, and the use of Huang and asymptotic diffuse scattering for the determination of the size, type, and internal structure of clustered defects is discussed. The scattering amplitude for diffuse scattering from lattice defects is presented within the single defect approximation, and the physical interpretation of the asymptotic diffuse scattering from dislocation loops and precipitates is discussed in terms of local Bragg scattering. The importance of using detailed and accurate displacement fields for calculating diffuse scattering cross sections for dislocation loops and coherent precipitates is emphasized, and examples of the measurement of size distributions for vacancy and interstitial loops and for coherent precipitates in Cu are revisited. In addition, the use of submicrometer-diameter X-ray microbeams to perform depth-resolved diffuse scattering measurements of vacancy and interstitial loop distributions in 10 MeV self-ion-implanted silicon single crystals is discussed.

36 MATERIALS SCIENCE↗

Carbon nanotube collimator fabrication and application

Apparatus, methods, systems and devices for fabricating individual CNT collimators. Micron size fiber coated CNT samples are synthesized with chemical vapor deposition method and then the individual CNT collimators are fabricated with focused ion beam technique. Unfocused electron beams are successfully propagated through the CNT collimators. The CNT nano-collimators are used for applications including single ion implantation and in high-energy physics, and allow rapid, reliable testing of the transmission of CNT arrays for transport of molecules.

Chow, Lee↗

Propagation of misfit dislocations from buffer/Si interface into Si

Misfit dislocations are redirected from the buffer/Si interface and propagated to the Si substrate due to the formation of bubbles in the substrate. The buffer layer growth process is generally a thermal process that also accomplishes annealing of the Si substrate so that bubbles of the implanted ion species are formed in the Si at an appropriate distance from the buffer/Si interface so that the bubbles will not migrate to the Si surface during annealing, but are close enough to the interface so that a strain field around the bubbles will be sensed by dislocations at the buffer/Si interface and dislocations are attracted by the strain field caused by the bubbles and move into the Si substrate instead of into the buffer epi-layer. Fabrication of improved integrated devices based on GaN and Si, such as continuous wave (CW) lasers and light emitting diodes, at reduced cost is thereby enabled.

36 MATERIALS SCIENCE↗

Polarization induced doped transistor

A nitride-based field effect transistor (FET) comprises a compositionally graded and polarization induced doped p-layer underlying at least one gate contact and a compositionally graded and doped n-channel underlying a source contact. The n-channel is converted from the p-layer to the n-channel by ion implantation, a buffer underlies the doped p-layer and the n-channel, and a drain underlies the buffer.

36 MATERIALS SCIENCE↗

Spiral biasing adaptor for use in Si drift detectors and Si drift detector arrays

A drift detector array, preferably a silicon drift detector (SDD) array, that uses a low current biasing adaptor is disclosed. The biasing adaptor is customizable for any desired geometry of the drift detector single cell with minimum drift time of carriers. The biasing adaptor has spiral shaped ion-implants that generate the desired voltage profile. The biasing adaptor can be processed on the same wafer as the drift detector array and only one biasing adaptor chip/side is needed for one drift detector array to generate the voltage profiles on the front side and back side of the detector array.

36 MATERIALS SCIENCE↗

Investigation of radiation damage tolerance in interface-containing metallic nano structures

The proposed work seeks to conduct a basic study by applying experimental and computational methods to obtain quantitative influence of helium sink strength and proximity on He bubble nucleation and growth in He-irradiated nano-scale metallic structures, and the ensuing deformation mechanisms and mechanical properties. We utilized a combination of nano-scale in-situ tension and compression experiments on low-energy He-irradiated samples combined with site-specific microstructural characterization and modeling efforts. We also investigated the mechanical deformation of nano-architected materials, i.e. nanolattices which are comprised of 3-dimensional interwoven networks of hollow tubes, with the wall thickness in the nanometer range. This systematic approach will provide us with critical information for identifying key factors that govern He bubble nucleation and growth upon irradiation as a function of both sink strength and sink proximity through an experimentally-confirmed physical understanding. As an outgrowth of these efforts, we performed irradiations with self-ions (Ni 2+ ) on Ni-Al-Zr metallic glass nanolattices to assess their resilience against radiation damage rather than He-ion implantation. We focused our attention on studying individual bcc/fcc interfaces within a single nano structure (nano-pillar or a hollow tube): a single Fe (bcc)-Cu (fcc) boundary per pillar oriented perpendicular to the pillar axes, as well as pure bcc and fcc nano structures. Additional interfaces of interest include bcc/bcc and metal/metallic glass all within a single nano-structure volume. The model material systems are: (1) pure single crystalline Fe and Cu, (2) a single Fe (bcc)-Cu (fcc) boundary per nano structure (3) a single metal–metallic glass, all oriented non-parallel to the loading direction so that their fracture strength can be tested. A nano-fabrication approach, which involves e-beam lithography and templated electroplating, as well as two-photon lithography, was utilized, which enabled precise control of the initial microstructure control. Experimentally determined stress-strain relationships were enhanced by in-situ SEM observations coupled with TEM microstructural characterization of the same samples before and after deformation (irradiated and as-fabricated) and atomistic (MD) modeling. A comprehensive suite of experiments was conducted to quantitatively assess the key parameters for He bubble nucleation and growth by independently varying the sink strength, sink proximity, and He implantation temperature and dose. The implantations were conducted at Sandia and Los Alamos National Labs (CINT). Nano structuress containing He-enriched interfaces and irradiation-damaged microstructure were tested under uniaxial tension to assess embrittlement, resulting boundary strength, and deformation mechanisms. Results of this work helped identify which types of interfaces are particularly resilient against radiation damage.

36 MATERIALS SCIENCE↗

PROGRESS IN THE STUDY OF ION IRRADIATION IN TUNGSTEN

The experimental study intends to generate data to validate the theoretical predictions on defect accumulation and recovery, as well as to investigate microstructural evolution and transmutant precipitation in mono- and poly-crystalline tungsten using ion implantation.

Environmental Molecular Sciences Laboratory↗

Towards Cryogen-Free SRF Particle Accelerators

Particle accelerators have been essential tools of particle physics since initial development in the early twentieth century, with commercial applications soon following each successive advancement. Furthermore, particle accelerators today are found in diverse use, ranging from ion-implantation of consumer electronics to both imaging and treatment of cancers.

43 PARTICLE ACCELERATORS↗

Reliable electrical contacts for high power photoconductive switches

A photoconductive switch consisting of an optically actuated photoconductive material, e.g. a wide bandgap semiconductor such as SiC, situated between opposing electrodes. The electrodes are created using various methods in order to maximize reliability by reducing resistive heating, current concentrations and filamentation, and heating and ablation due to the light source. This is primarily accomplished by the configuration of the electrical contact geometry, choice of contacts metals, annealing, ion implantation, creation of recesses within the SiC, and the use of coatings to act as encapsulants and anti-reflective layers.

42 ENGINEERING↗

Ion beam modification of noble metals for electrical contacts

Ion beam modification of noble metal electrical contact coatings can achieve suitable friction and wear behavior with inherently stable low ECR. For example, this method of producing Au electrical contact coatings can produce wear properties similar to electroplated hard Au, but without the environmental concerns due to stringent OSHA regulations on the use and disposal of toxic chemicals associated with Au electroplating baths. Integration of physical vapor deposition techniques with ion implantation can produce noble metal coatings with surfaces modified to achieve the desired balance between adhesion/friction/wear and electrical contact resistance on a commercial scale.

36 MATERIALS SCIENCE↗

Method of authenticating integrated circuits using optical characteristics of physically unclonable functions

A method and apparatus for reading unique identifiers of an integrated circuit. The unique identifiers may be physically unclonable functions (PUFs), formed by high energy ions implanted into semiconductor material of the integrated circuit. The method may include electrically or optically stimulating each of the PUFs and sensing with an optical sensor optical characteristics of resulting light emitted from the PUFs. Then the method may include comparing values associated with the optical characteristics of the PUFs with groups of stored values in a circuit database. Each of the groups of stored values may be associated with optical characteristics of PUFs of a known authentic circuit. The method may then include the controller providing verification of authenticity of the integrated circuit when each of the values associated with the optical characteristics of the PUFs match the stored values of at least one of the groups in the circuit database.

42 ENGINEERING↗

Doped passivated contacts

PolySi:Ga/SiO2 passivated contacts were prepared using ion implantation and dopant inks to introduce Ga into a-Si. Following crystallization anneals these p-type contacts exhibited improved passivation (iVoc of about 730 mV) over B-doped passivated contacts for solar cells.

Young, David Levi↗

Measurement of the neutrino-spin correlation parameter B neutron decay using ultracold neutrons

We present a new approach to measuring the neutrino-spin correlation parameter B in neutron decay. The approach combines the technology of large-area ion-implanted silicon detectors being developed for the abBA experiment, with an ultracold neutron source to provide more precise neutron polarimetry. The technique detects both proton and electron from the neutron decay in coincidence. B is determined from an electron-energy-dependent measurement of the proton spin asymmetry. This approach will provide a statistical precision of 1 x 10-4 . The systematic precision is still being evaluated, but is expected to be below 1 x 10-3 , and could approach 1 x 10-4 . A measurement of B with this precision would place constraints on supersymmetric extensions to the Standard Model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Device fabrication and transport measurements of FinFETs built with 28Si SOI wafers towards donor qubits in silicon

We report fabrication of transistors in a FinFET geometry using isotopically purified silicon-28 -on-insulator (28-SOI) substrates. Donor electron spin coherence in natural silicon is limited by spectral diffusion due to the residual 29Si nuclear spin bath, making isotopically enriched nuclear spin-free 28Si substrates a promising candidate for forming spin quantum bit devices. The FinFET architecture is fully compatible with single-ion implant detection for donor-based qubits, and the donor spin-state readout through electrical detection of spin resonance. We describe device processing steps and discuss results on electrical transport measurements at 0.3 K.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Note: An ion source for alkali metal implantation beneath graphene and hexagonal boron nitride monolayers on transition metals

The construction of an alkali-metal ion source is presented. It allows the acceleration of rubidium ions to an energy that enables the penetration through monolayers of graphene and hexagonal boron nitride. Rb atoms are sublimated from an alkali-metal dispenser. The ionization is obtained by surface ionization and desorption from a hot high work function surface. The ion current is easily controlled by the temperature of ionizer. Scanning Tunneling Microscopy measurements confirm ion implantation.

36 MATERIALS SCIENCE↗

Friction wear and auger analysis of iron implanted with 1.5-MeV nitrogen ions

The effect of implantation of 1.5-MeV nitrogen ions on the friction and wear characteristics of pure iron sliding against steel was studied in a pin-on disk apparatus. An implantation dose of 5 x 10 to the 17th power ions/sq cm was used. Small reductions in initial and steady-state wear rates were observed for nitrogen-implanted iron riders as compared with unimplanted controls. Auger electron spectroscopy revealed a subsurface Gaussian nitrogen distribution with a maximum concentration of 15 at. % at a depth of 8 x 10 to the -7th m. A similar analysis within the wear scar of an implanted rider after 20 microns of wear yielded only background nitrogen concentration, thus giving no evidence for diffusion of nitrogen beyond the implanted range.

Ferrante, J.↗