Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Intensity modulated neutron radiotherapy optimization by photon proxy

Purpose: Introducing intensity modulation into neutron radiotherapy (IMNRT) planning has the potential to mitigate some normal tissue complications seen in past neutron trials. While the hardware to deliver IMNRT plans has been in use for several years, until recently the IMNRT planning process has been cumbersome and of lower fidelity than conventional photon plans. Our in-house planning system used to calculate neutron therapy plans allows beam weight optimization of forward planned segments, but does not provide inverse optimization capabilities. Commercial treatment planning systems provide inverse optimization capabilities, but currently cannot model our neutron beam. Methods: We have developed a methodology and software suite to make use of the robust optimization in our commercial planning system while still using our in-house planning system to calculate final neutron dose distributions. Optimized multileaf collimator (MLC) leaf positions for segments designed in the commercial system using a 4 MV photon proxy beam are translated into static neutron ports that can be represented within our in-house treatment planning system. The true neutron dose distribution is calculated in the in-house system and then exported back through the MATLAB software into the commercial treatment planning system for evaluation. Results: The planning process produces optimized IMNRT plans that reduce dose to normal tissue structures as compared to 3D conformal plans using static MLC apertures. The process involves standard planning techniques using a commercially available treatment planning system, and is not significantly more complex than conventional IMRT planning. Using a photon proxy in a commercial optimization algorithm produces IMNRT plans that are more conformal than those previously designed at our center and take much less time to create. Conclusions: The planning process presented here allows for the optimization of IMNRT plans by a commercial treatment planning optimization algorithm, potentially allowing IMNRT to achieve similar conformality in treatment as photon IMRT. The only remaining requirements for the delivery of very highly modulated neutron treatments are incremental improvements upon already implemented hardware systems that should be readily achievable.

60 APPLIED LIFE SCIENCES↗

Spatial Resolution of a microCT Scanner

We have measured the spatial resolution of the 450 kV test-bed microCT scanner. We have also modeled the resolution analytically. The model and measurement show correspondence within 5%. Our measurement method was to use a thin tungsten wire to act as an impulse function. Therefore, the image is the impulse response, also called the point spread function (PSF) of the system. The Fourier transform (FT) of the impulse response is the modulation transfer function (MTF) of the system. We report the MTF here. By moving the wire at different positions in the scan field of view (FOV), we can measure MTF at different positions in the FOV. Since our imaging system is radially symmetric, we report MTF in two directions, radial and tangential as shown in Figure 1. The radial direction is along the line from isocenter to the wire, and the tangential is perpendicular to it.

42 ENGINEERING↗

Problems Found Using a Radon Stripping Algorithm for Retrospective Assessment of Air Filter Samples

An evaluation of a large number of air sample filters was undertaken using a commercial alpha and beta spectroscopy system employing a passive implanted planar silicon (PIPS) detector. Samples were only measured after air flow through the filters had ceased. Use of a commercial radon stripping algorithm was implemented to discriminate anthropogenic alpha activity on the filters from the radon progeny. When uncontaminated air filters were evaluated, the results showed that there was a time-dependent bias in both average estimates and measurement dispersion of anthropogenic activity estimates with the relative bias being small compared to the dispersion, indicating that the system would not give false positive indications for an appropriately set decision level. By also measuring environmental air sample filters simultaneously with electroplated alpha filters, use of the radon stripping algorithm demonstrated a number of substantial unexpected deviations from calibrated values indicating that the system would give false negative indications. Use of the current algorithm is, therefore, not recommended for general assay applications. Use of the PIPS detector should only be utilized for gross counting without appropriate modifications to the curve-fitting algorithm. As a screening method, the radon stripping algorithm might be expected to see elevated alpha activities on air sample filters (not due to radon progeny) around the 200 disintegrations per minute level.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hyperchromatic lens for recording time-resolved phenomena

A method and apparatus for the capture of a high number of quasi-continuous effective frames of 2-D data from an event at very short time scales (from less than 10.sup.-12 to more than 10.sup.-8 seconds) is disclosed which allows for short recording windows and effective number of frames. Active illumination, from a chirped laser pulse directed to the event creates a reflection where wavelength is dependent upon time and spatial position is utilized to encode temporal phenomena onto wavelength. A hyperchromatic lens system receives the reflection and maps wavelength onto axial position. An image capture device, such as holography or plenoptic imaging device, captures the resultant focal stack from the hyperchromatic lens system in both spatial (imaging) and longitudinal (temporal) axes. The hyperchromatic lens system incorporates a combination of diffractive and refractive components to maximally separate focal position as a function of wavelength.

47 OTHER INSTRUMENTATION↗

Benchmarking thermal energy storage cost for industrial process heat

Process heat accounts for roughly half of industrial energy demand, and currently 95% of process heat is derived from the combustion of natural gas, oil, and coal. Electrification of industrial heating could be an alternative, potentially expanding locations suitable for manufacturing; however, industrial facility owners may desire energy storage to stabilize energy costs. In this work, the economic benefits of pairing thermal storage with electrified process heat to reduce the average price paid for energy are analyzed. Cost savings focus on energy arbitrage, or leveraging flexible energy pricing schemes, alone. The cost of natural gas combustion across decades (2019-2060) is compared to the costs of electricity and thermal energy storage in four United States Independent System Operator (ISO) regions. Systems installed today may not yield positive net present value (NPV) compared to the use of natural gas. However, using estimated electricity prices, systems installed in 2030 using arbitrage alone could be profitable when compared to natural gas in some regions of the U.S. Furthermore, if capital expenditures could be reduced by 50% for sensible thermal storage systems by 2030, profitable systems are found across all regions. This implies that electrification of industrial process heat, when paired with inexpensive thermal energy storage systems, could be less expensive than brownfield natural gas systems, using arbitrage as the only source of revenue and without a dependency on any future policy drivers such as pricing externalities that could further incentivize the electrification of industrial process heat.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Engineering topologically protected superconducting states

Efforts to develop systems which support non-Abelian excitations are motivated by both scientific curiosity and a practical desire to built a fault tolerant quantum computer to solve problems fundamentally intractable for classical computations. Experimentally, signatures of simplest non-Abelian excitations have been seen in spectroscopic measurements, yet current experiments fall shot of demonstrating non-Abelian exchange statistics. With DOE support we explore several systems where non-Abelian excitations are expected to appear, with special attention paid to the ability to demonstrate braiding. In nanowire semiconductor/superconductor hybrid system we are developing devices where position of Majorana particles, the simplest non-Abelian excitations, can be varied by magnetic field. The system will allow braiding of Majorana fermions and study non-Abelian statistics. In another system we focus on the development of a new platform where higher order non-Abelian excitations - parafermions - can be realized. Recently we demonstrated formation of heliacal channels in the fractional quantum Hall regime, precursors of topological superconductors that support parafermion excitations. Investigation of these channels and induced superconductivity will be an important part of the proposed research. Finally, investigation of induced superconductivity in topological insulators and discovery of highly unharmonic current-phase relation in Josephson junctions is the basis for the proposed realization of a topologically protected qubits with abelian anions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Rankine cycle system and method

A Rankine cycle waste heat recovery system uses a receiver with a maximum liquid working fluid level lower than the minimum liquid working fluid level of a sub-cooler of the waste heat recovery system. The receiver may have a position that is physically lower than the sub-cooler's position. A valve controls transfer of fluid between several of the components in the waste heat recovery system, especially from the receiver to the sub-cooler. The system may also have an associated control module.

42 ENGINEERING↗

Subsets of Women With Close or Positive Margins After Breast-Conserving Surgery With High Local Recurrence Risk Despite Breast Plus Boost Radiotherapy

Purpose: (1) To examine the effect of surgical margin status on local recurrence (LR) and survival following breast-conserving therapy; (2) To identify subsets with close or positive margins with high LR risk despite whole breast radiotherapy (RT) plus boost. Methods and Materials: Subjects were 2,264 women with pT1-3, any N, M0 invasive breast cancer, treated with breast-conserving surgery and whole breast {+-} boost RT. Five-year Kaplan-Meier (KM) LR, breast cancer-specific and overall survival (BCSS and OS) were compared between cohorts with negative (n = 1,980), close (n = 222), and positive (n = 62) margins. LR rates were analyzed according to clinicopathologic characteristics. Multivariable Cox regression modeling and matched analysis of close/positive margin cases and negative margin controls were performed. Results: Median follow-up was 5.2 years. Boost RT was used in 92% of patients with close or positive margins. Five-year KM LR rates in the negative, close and positive margin cohorts were 1.3%, 4.0%, and 5.2%, respectively (p = 0.001). BCSS and OS were similar in the three margin subgroups. In the close/positive margin cohort, LR rates were 10.2% with age <45 years, 11.8% with Grade III, 11.3% with lymphovascular invasion (LVI), and 26.3% with {>=}4 positive nodes. Corresponding rates in the negative margin cohort were 2.3%, 2.4%, 1.0%, and 2.4%, respectively. On Cox regression analysis of the entire cohort, close or positive margin, Grade III histology, {>=}4 positive nodes, and lack of systemic therapy were significantly associated with higher LR risk. When close/positive margin cases were matched to negative margin controls, the difference in 5-year LR remained significant (4.25% vs. 0.7%, p < 0.001). Conclusions: On univariable analysis, subsets with close or positive margins, in combination with age <45 years, Grade III, LVI, and {>=}4 positive nodes, have 5-year LR >10% despite whole breast plus boost RT. These patients should be considered for more definitive surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Demonstration Report: Handheld UXO Discriminator, SERDP No. MR-1667

In 2003, the Defense Science Board observed: 'The problem is that instruments that can detect the buried UXOs also detect numerous scrap metal objects and other artifacts, which leads to an enormous amount of expensive digging. Typically 100 holes may be dug before a real UXO is unearthed! The Task Force assessment is that much of this wasteful digging can be eliminated by the use of more advanced technology instruments that exploit modern digital processing and advanced multi-mode sensors to achieve an improved level of discrimination of scrap from UXOs.' In keeping with these remarks and with prior funding (UX-1225, MM-0437, and MM-0838), the LBNL group has successfully designed and built the cart-mounted Berkeley UXO Discriminator (BUD) and demonstrated its performance at various test sites (cf. Gasperikova et al., 2007, 2008, and 2009). Because hand-held systems have the advantage of being lightweight, compact, portable, and deployable under most site conditions, they are particularly useful in areas of dense vegetation or challenging terrain. In heavily wooded areas or areas with steep or uneven terrain, hand-held sensors may be the only suitable device for UXO detection and discrimination because it can be carried through spaces that the operator could walk through or at least approach. Furthermore, it is desirable to find and characterize a metallic object without the need to accurately locate the sensors at multiple positions around the target. The ideal system would thus locate and characterize the target from a single position of the sensor and indicate to the operator where to flag the target for subsequent study. Based on these considerations, we designed and built a sensor package in a shape of a 14-in (0.35 m) cube. This hand-held prototype incorporates the key features of the cart-mounted system - (a) three orthogonal transmitters and ten pairs of receivers, and (b) difference or gradient measurements that significantly reduce the ambient and motion noise, and greatly enhance the sensitivity to the gradients of the target. The system characterizes the target from a single position. Results from a local test site were in a good agreement with theoretical performance calculations of such a device. This survey was designed to demonstrate performance of the system under realistic survey conditions at the Aberdeen Proving Ground (APG) in Aberdeen, MD. The survey was preformed in an area with known items ('Calibration Grid'), and in a seeded blind test area (the 'Blind Test Grid'). The ground truth for the surveys conducted on the Blind Test Grid was withheld from the testers. Only the graded test scores based on target detection and target classification were provided. For more information, see http://aec.army.mil/usaec/technology/uxo01c03.html.

54 ENVIRONMENTAL SCIENCES↗

RED GIANTS IN ECLIPSING BINARY AND MULTIPLE-STAR SYSTEMS: MODELING AND ASTEROSEISMIC ANALYSIS OF 70 CANDIDATES FROM KEPLER DATA

Red giant stars are proving to be an incredible source of information for testing models of stellar evolution, as asteroseismology has opened up a window into their interiors. Such insights are a direct result of the unprecedented data from space missions CoRoT and Kepler as well as recent theoretical advances. Eclipsing binaries are also fundamental astrophysical objects, and when coupled with asteroseismology, binaries provide two independent methods to obtain masses and radii and exciting opportunities to develop highly constrained stellar models. The possibility of discovering pulsating red giants in eclipsing binary systems is therefore an important goal that could potentially offer very robust characterization of these systems. Until recently, only one case has been discovered with Kepler. We cross-correlate the detected red giant and eclipsing-binary catalogs from Kepler data to find possible candidate systems. Light-curve modeling and mean properties measured from asteroseismology are combined to yield specific measurements of periods, masses, radii, temperatures, eclipse timing variations, core rotation rates, and red giant evolutionary state. After using three different techniques to eliminate false positives, out of the 70 systems common to the red giant and eclipsing-binary catalogs we find 13 strong candidates (12 previously unknown) to be eclipsing binaries, one to be a non-eclipsing binary with tidally induced oscillations, and 10 more to be hierarchical triple systems, all of which include a pulsating red giant. The systems span a range of orbital eccentricities, periods, and spectral types F, G, K, and M for the companion of the red giant. One case even suggests an eclipsing binary composed of two red giant stars and another of a red giant with a {delta}-Scuti star. The discovery of multiple pulsating red giants in eclipsing binaries provides an exciting test bed for precise astrophysical modeling, and follow-up spectroscopic observations of many of the candidate systems are encouraged. The resulting highly constrained stellar parameters will allow, for example, the exploration of how binary tidal interactions affect pulsations when compared to the single-star case.

79 ASTRONOMY AND ASTROPHYSICS↗

AutoFocus: AI-driven alignment of nanofocusing X-ray mirror systems

We describe the application of an AI-driven system to autonomously align complex x-ray-focusing mirror systems, including mirrors systems with variable focus spot sizes. The system has been developed and studied on a digital twin of nanofocusing X-ray beamlines, built using advanced optical simulation tools calibrated with wavefront sensing data collected at the beamline. We experimentally demonstrated that the system is reliably capable of positioning a focused beam on the sample, both by simulating the variation of a beamline with random perturbations due to typical changes in the light source and optical elements over time, and by conducting similar tests on an actual focusing mirror system.

47 OTHER INSTRUMENTATION↗

Mathematical Models for Optimization of Grid-Integrated Energy Storage Systems

Energy storage has been proven to yield positive effects on planning, operation and control of electric grids. It has become a crucial task to properly model the energy storage systems (ESS) under the framework of grid optimization on transmission and distribution networks including microgrids. This paper presents a review on mathematical models and test cases of ESSs used for grid optimization studies, where the network constraints of power systems are included. The existing ESS models are mainly classified into two categories – linear and nonlinear models. The two main categories are further divided into several subcategories respectively; such as mixed-integer linear and convex nonlinear sub-categories. Based on the review and discussions, this paper aims at providing suggestions for choosing proper ESS models for specific grid optimization studies considering the chosen power network model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Problem of Package Guidance with Incomplete Information for a Linear Control System with a Delay

The control-package method is applied to solve the problem of constructing guaranteed positional guidance for a linear control dynamical system with a delay under incomplete information about the initial state. The problem is solved for the case when the initial state is contained in a compact functional set. A solvability criterion and a method for the construction of a guidance program package are proposed. The proposed procedure is applied to a particular linear control system of delayed differential equations.

97 MATHEMATICS AND COMPUTING↗

A multicenter study to quantify systematic variations and associated uncertainties in source positioning with commonly used HDR afterloaders and ring applicators for the treatment of cervical carcinomas

Purpose: The reconstruction of radiation source position in the treatment planning system is a key part of the applicator reconstruction process in high dose rate (HDR) brachytherapy treatment of cervical carcinomas. The steep dose gradients, of as much as 12%/mm, associated with typical cervix treatments emphasize the importance of accurate and precise determination of source positions. However, a variety of methodologies with a range in associated measurement uncertainties, of up to ±2.5 mm, are currently employed by various centers to do this. In addition, a recent pilot study by Awunor et al. [“Direct reconstruction and associated uncertainties of {sup 192}Ir source dwell positions in ring applicators using gafchromic film in the treatment planning of HDR brachytherapy cervix patients,” Phys. Med. Biol. 58, 3207–3225 (2013)] reported source positional differences of up to 2.6 mm between ring sets of the same type and geometry. This suggests a need for a comprehensive study to assess and quantify systematic source position variations between commonly used ring applicators and HDR afterloaders across multiple centers. Methods: Eighty-six rings from 20 European brachytherapy centers were audited in the form of a postal audit with each center collecting the data independently. The data were collected by setting up the rings using a bespoke jig and irradiating gafchromic films at predetermined dwell positions using four afterloader types, MicroSelectron, Flexitron, GammaMed, and MultiSource, from three manufacturers, Nucletron, Varian, and Eckert & Ziegler BEBIG. Five different ring types in six sizes (Ø25–Ø35 mm) and two angles (45° and 60°) were used. Coordinates of irradiated positions relative to the ring center were determined and collated, and source position differences quantified by ring type, size, and angle. Results: The mean expanded measurement uncertainty (k = 2) along the direction of source travel was ±1.4 mm. The standard deviation associated with the source position reproducibility was within ±1.0 mm for all afterloaders. Maximum source positional variations of 2.1 and 3.9, 1.8 and 5.4, and 2.3 and 3.4 mm were observed at standard treatment positions for the Ø26, Ø30, and Ø32 mm sized 45° and 60° rings, respectively. Mean positional differences between a majority of the rings were within ±1.0 mm. Mean positional differences between a majority of the intracenter ring sets were within the expanded measurement uncertainty. When comparing the 45°–60° source paths, mean differences of 1.6, 0.9, and 0.9 mm were observed across the Ø26, Ø30 (MicroSelectron), and Ø32 mm (GammaMed) rings, respectively. When comparing to manufacturer source path models, maximum offsets of 1.9 and 2.1, 2.6 and 2.3, and 0.8 and 1.6 mm were observed for the Ø26, Ø30 (MicroSelectron), and Ø30 mm (Flexitron) sized 45° and 60° rings, respectively. When comparing the audit to ring commissioning data of participating centers, mean differences of up to 2.4 mm were observed. Conclusions: A majority of the audited rings showed a good degree of manufacturer consistency; however, substantial positional variation observed between some rings emphasizes the importance of commissioning each ring before clinical use. Differences observed between audit and commissioning data also indicate some variation in source treatment positions across centers.

60 APPLIED LIFE SCIENCES↗

Method and system for assembling miniaturized devices

An apparatus for assembling a miniaturized device includes a manipulator system including six manipulators operable to position and orient components of the miniaturized device with submicron precision and micron-level accuracy. The manipulator system includes a first plurality of motorized axes, a second plurality of manual axes, and force and torque and sensors. Each of the six manipulators includes at least one translation stage, at least one rotation stage, tooling attached to the at least one translation stage or the at least one rotation stage, and an attachment mechanism disposed at a distal end of the tooling and operable to attach at least a portion of the miniaturized device to the tooling. The apparatus also includes an optical coordinate-measuring machine (OCMM) including a machine-vision system, a laser-based distance-measuring probe, and a touch probe. The apparatus also includes an operator control system coupled to the manipulator system and the OCMM.

47 OTHER INSTRUMENTATION↗

Controlling a power output of a nuclear reaction without control rods

A nuclear power system includes a reactor vessel that includes a reactor core mounted therein. The reactor core includes nuclear fuel assemblies configured to generate a nuclear fission reaction. The reaction vessel does not include any control rod assemblies therein. The nuclear power system further includes a riser positioned above the reactor core, a primary coolant flow path, a primary coolant that circulates through the primary coolant flow path to receive heat from the nuclear fission reaction and release the received heat to generate electric power in a power generation, and a control system communicably coupled to the power generation system and configured to control a power output of the nuclear fission reaction independent of any control rod assemblies.

Callaway, Allyson↗

Accuracy of electromagnetic tracking with a prototype field generator in an interventional OR setting

Purpose: The authors have studied the accuracy and robustness of a prototype electromagnetic window field generator (WFG) in an interventional radiology suite with a robotic C-arm. The overall purpose is the development of guidance systems combining real-time imaging with tracking of flexible instruments for bronchoscopy, laparoscopic ultrasound, endoluminal surgery, endovascular therapy, and spinal surgery. Methods: The WFG has a torus shape, which facilitates x-ray imaging through its centre. The authors compared the performance of the WFG to that of a standard field generator (SFG) under the influence of the C-arm. Both accuracy and robustness measurements were performed with the C-arm in different positions and poses. Results: The system was deemed robust for both field generators, but the accuracy was notably influenced as the C-arm was moved into the electromagnetic field. The SFG provided a smaller root-mean-square position error but was more influenced by the C-arm than the WFG. The WFG also produced smaller maximum and variance of the error. Conclusions: Electromagnetic (EM) tracking with the new WFG during C-arm based fluoroscopy guidance seems to be a step forward, and with a correction scheme implemented it should be feasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement of positive direct current corona pulse in coaxial wire-cylinder gap

In this paper, a system is designed and developed to measure the positive corona current in coaxial wire-cylinder gaps. The characteristic parameters of corona current pulses, such as the amplitude, rise time, half-wave time, and repetition frequency, are statistically analyzed and a new set of empirical formulas are derived by numerical fitting. The influence of space charges on corona currents is tested by using three corona cages with different radii. A numerical method is used to solve a simplified ion-flow model to explain the influence of space charges. Based on the statistical results, a stochastic model is developed to simulate the corona pulse trains. And this model is verified by comparing the simulated frequency-domain responses with the measured ones.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗