Search NASA⌕ Search

SEARCH · Search NASA

Results for “Temperature Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

A terahertz plasmon cavity detector

Sensitivity of a plasmonic detector is enhanced by integrating a broadband log-periodic antenna with a two-dimensional plasma cavity that is defined by source, drain, and multiple gates of a GaAs/AlGaAs high electron mobility transistor. Both narrow-band terahertz detection and a rich harmonic spectrum are evident. With a bolometric sensor in the channel, we report responsivity, on resonance at 235-240 GHz and at 20 K, of up to 7 kV/W and a noise equivalent power of 5x10{sup -10} W/Hz{sup 1/2}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

New Products

In order to supplement manufacturers' information this Department will welcome the submission by our readers of brief communications reporting measurements on the physical properties of materials which supersede earlier data or suggest new research applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Expanded beam deflection method for simultaneous measurement of displacement and vibrations of multiple microcantilevers

Here we present an extension of optical beam deflection (OBD) method for measuring displacement and vibrations of an array of microcantilevers. Instead of focusing on the cantilever, the optical beam is either focused above or below the cantilever array, or focused only in the axis parallel to the cantilevers length, allowing a wide optical line to span multiple cantilevers in the array. Each cantilever reflects a part of the incident beam, which is then directed onto a photodiode array detector in a manner allowing distinguishing between individual beams. Each part of reflected beam behaves like a single beam of roughly the same divergence angle in the bending sensing axis as the incident beam. Since sensitivity of the OBD method depends on the divergence angle of deflected beam, high sensitivity is preserved in proposed expanded beam deflection (EBD) method. At the detector, each spot's position is measured at the same time, without time multiplexing of light sources. This provides real simultaneous readout of entire array, unavailable in most of competitive methods, and thus increases time resolution of the measurement. Expanded beam can also span another line of cantilevers allowing monitoring of specially designed two-dimensional arrays. In this paper, we present first results of application of EBD method to cantilever sensors. We show how thermal noise resolution can be easily achieved and combined with thermal noise based resonance frequency measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A vacuum gauge based on an ultracold gas

We report the design and application of a primary vacuum gauge based on an ultracold gas of atoms in an optical dipole trap. The pressure is calculated from the confinement time for atoms in the trap. The relationship between pressure and confinement time is established from the first principles owing to elimination of all channels introducing losses, except for knocking out an atom from the trap due to collisions with a residual gas particle. The method requires the knowledge of the gas chemical composition in the vacuum chamber, and, in the absence of this information, the systematic error is less than that of the ionisation sensor. (paper)

74 ATOMIC AND MOLECULAR PHYSICS↗

Thermomechanical Degradation of Sintered Copper Under High-Temperature Thermal Shock

The need for reliable bonded interface materials is critical to realize the performance benefits of wide-bandgap devices in power electronics modules, especially in operating temperatures greater than 150 degrees C. In this paper, we investigate the thermomechanical performance of sintered copper (Cu) as a large-area attachment, bonded between Cu baseplates and active-metal-bonded substrates, under accelerated thermal shock (-40 degrees C to 200 degrees C) conditions. In the fabrication phase of the samples, we used different stencil patterns and found that the grid and stripe patterns resulted in a better outgassing of the residual organics during the sintering process, thereby ensuring a substantially improved bond quality compared to a full-area print. The paste consisted of Cu microflakes, and we performed sintering using a Budatec SP300 sintering press at 275 degrees C with 15 MPa of bonding pressure for 5 minutes in a nitrogen atmosphere. Under accelerated experiments, we monitored the degradation of the sintered Cu bond in the samples through C-mode scanning acoustic microscope (C-SAM) images. To quantify the defect percentage in C-SAM images, we investigated image denoising techniques to exclude the pattern prints. Finally, we cross-sectioned a sample and obtained scanning electron microscope images, which revealed adhesive fracture as the dominant failure mechanism.

ADVANCED PROPULSION SYSTEMS,INORGANIC, ORGANIC, PH↗

Measurements and Modeling of III-V Solar Cells at High Temperatures up to 400 °C

Here in this paper, we study the performance of 2.0 eV Al 0.12 Ga 0.39 In 0.49 P and 1.4 eV GaAs solar cells over a temperature range of 25-400 degrees °C. The temperature-dependent J 01 and J 02 dark currents are extracted by fitting current-voltage measurements to a two-diode model. We find that the intrinsic carrier concentration ni dominates the temperature dependence of the dark currents, open-circuit voltage, and cell efficiency. To study the impact of temperature on the photocurrent and bandgap of the solar cells, we measure the quantum efficiency and illuminated current-voltage characteristics of the devices up to 400 °C. As the temperature is increased, we observe no degradation to the internal quantum efficiency and a decrease in the bandgap. These two factors drive an increase in the short-circuit current density at high temperatures. Finally, we measure the devices at concentrations ranging from ~30 to 1500 suns and observe n = 1 recombination characteristics across the entire temperature range. These findings should be a valuable guide to the design of any system that requires high-temperature solar cell operation.

14 SOLAR ENERGY↗

Construction of a New MgB 2 Coating System for 1.3-GHz Superconducting RF Cavities at LANL

After many years of evaluating MgB 2 films prepared with various techniques for the application to superconducting radio-frequency (SRF) cavities, we have decided to build a system to coat full-size 1.3-GHz elliptical cavities. This paper describes the design and construction of the system. Additionally, we briefly describe experimental results with a small system and first tests with the new large system. In conclusion, we were able to obtain superconducting samples with a T c of up to 38 K with the small system, but we have not been able to get any superconducting samples with the new system yet.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sensalert: A Real-time Group and Individual Health Tracking Application

Sensalert is a wearable health tracking application that enables monitoring of a target population’s health status in real-time. The application integrates health monitoring parameters from wearable sensors, e.g., temperature and heart rate, with relevant environmental parameters, e.g., weather and topography, and calculates the corresponding physiological strain index for each point in time. The objective of this application is to provide early warning, support decision making, and increase situational awareness by displaying comprehensive information and providing alerts at the right time and place. This application is the first of its kind being developed for integration into the Defense Threat Reduction Agencies Bio Surveillance Ecosystem (BSVE). We present the user requirements and design principles for developing this type of application. We hope this work helps and inspires future research in the area of wearable technologies for surveillance.

Huang, Zhuanyi↗

Mechanical Stability Study for Integrable Optics Test Accelerator at Fermilab

The Integrable Optics Test Accelerator (IOTA) is proposed for operation at Fermilab. The goal of IOTA is to create practical nonlinear accelerator focusing systems with a large frequency spread and stable particle motion. The IOTA is a 40 m circumference, 150 MeV (e-), 2.5 MeV (p⁺) diagnostic test ring. A heavy low frequency steel floor girder is proposed as the primary tier for IOTA device component support. Two design lengths; (8) 4 m and (2) 2.8 m long girders with identical cross section completely encompass the ring. This study focuses on the 4 m length girder and the development of a working prototype. Hydrostatic Level Sensor (HLS), temperature, metrology and fast motion measurements characterize the anticipated mechanical stability of the IOTA ring.

43 PARTICLE ACCELERATORS↗

Recovery of Silicon Carbide monitor irradiation temperature via continuous resistance measurement during annealing (Pt. II)

Silicon carbide (SiC) monitors provide a means of measuring peak irradiation temperature of experiment capsules in nuclear irradiation experiments. Neutron irradiation of a SiC monitor causes permanent lattice changes that are removed by annealing via heating to a temperature that exceeds the peak irradiation temperature. The annealing process results in changes to SiC physical characteristics that can be observed during the annealing process. This paper presents results of a method aimed at using electrical resistance, measured during a two-pass heating – cooling cycle as a means of recovering the irradiation temperature of a SiC monitor. Results indicate that the relationship between resistance and temperature of a SiC monitor shows a significant change in slope when the peak irradiation temperature is reached. This demonstrates the potential for this method to replace the current manual, and lengthy, process of post irradiation examination used to extract the peak irradiation temperature from irradiated SiC monitors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Report on ISR-1 High-Altitude Balloon Flight

To test small technologies at lower cost for space science applications, LANL has developed a small high altitude balloon payload that could, in the future, be regularly and inexpensively launched from LANL. A neutron detector, NEMO, was integrated to evaluate its performance in a space-like mixed-radiation environment and collect neutron data in the atmosphere. In collaboration with EES-14, a high-altitude balloon payload was launched from LANL Technical Area 51 on February 27, 2023 and April 17, 2023. For real-time geolocation, a SAM-M8Q M8 GNSS module was used to get position and time, and an Iridium RockBLOCK 9603 was used to communicate with the ground using the Iridium satellite fleet. These modules were all controlled using an Iteaduino Mega microcontroller board. Finally, a High Altitude Science Eagle Flight Computer with a temperature pressure sensor ran independently, writing data to an SD card. All of these modules were powered by a 5 mAh lithium polymer battery. The battery was attached to the bottom of the payload while the remaining electronics were embedded in the underside of the top of the payload. These modules were wired as seen in Figure 1-2. The Iteaduino Mega microcontroller board was programmed to use the RockBLOCK to send a message once every 10 minutes containing neutron and GPS data read off the NEMO and SAM M8Q, respectively. Once the message send attempt finished, the RockBLOCK would be slept for the rest of the 10 minute interval. The Eagle Flight Computer ran continuously throughout the flight, taking data every 6 seconds. The RockBLOCK message data was set up to be delivered from the Iridium satellite fleet to a website, where it was stored and parsed to create live maps and plots for analysis and balloon retrieval. The RockBLOCK message data was additionally configured to be sent to an email as a fail-safe. The payload was ground-tested successfully for over 50 hours, with multiple revisions occurring to best prepare for conditions at altitude and improve the software and firmware to fix any issues that cropped up with the data pipeline. Additional to the balloon payload, the flight had an attached iMet-4 radiosonde and Garmin T5 GPS Dog Collar. The radiosonde provided GPS and meteorological data. The T5 dog collar is used along with a Garmin Astro 430 to track the balloon at a range of up to 9 miles for retrieval. The balloon itself was initially a 1600 g meteorological balloon with an attached High Altitude Science parachute, both of which can be seen in Figure 1-3. After the first flight, the EES team swapped to a Rocketman parachute.

42 ENGINEERING↗

Radiation-Hardened GaN HEMT and Cell Design, Modeling, and Fabrication for Nuclear Instrumentation Applications

Recent advances in nuclear power generation technologies show great promise for efficient, safe generation of carbon-free power in the near future. Consequently, many new generation reactor designs are being pursued by government and industry groups, including both fission- and fusion-based technologies. Radiation- and temperature-tolerant sensor technology continues to advance, yet development of the electronics/instrumentation technologies suitable for these environments have fallen behind. Industry has adequately addressed harsh environment electronics needs for low earth orbit satellites, but the much more extreme conditions associated with electronics placed near or in a reactor core remain unaddressed. This project investigates the use of gallium nitride (GaN) circuit technology to address the unique needs for sensor interface electronics and communications in reactor environments. This report provides a summary of the first year’s project activities related to developing and optimizing devices and circuits for this GaN high electronic mobility transistor (HEMT) process. Activities reported include multiple analog and digital circuit designs simulated using custom Verilog-A models generated from measured GaN devices fabricated in the target process. Digital circuit designs included fundamental logic circuits such as an inverter, NAND, NOR, AND and OR gates, as well as a 5-stage ring oscillator. Each design was simulated using an open-source SPICE simulator, and an integrated circuit layout was produced of each design for use in future fabrication. Analog circuit designs focused on the fundamental building blocks to be used to construct sensor interface and communications circuits. These included current mirrors, matched differential pairs, and a Gilbert cell mixer design, each with an associated integrated circuit layout. Layout tools used for these designs included two open-source packages—KLayout and Magic—which were customized for specific use with the OSU GaN process layers. Design rules and preliminary device extraction capabilities were built for the Magic tool to enable device extraction and subsequent netlist generation for SPICE simulation. Finally, future research directions for year two are summarized. When the year-two directions are implemented, the project will be in position to advance the state of the art in electronics for near- or in-reactor sensor interfacing and communications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Smokeless Chimney using Smoke Opacity as a Combustion Control Parameter (CRADA Final Report)

If operated poorly, wood burning heaters can produce large amounts of particulate matter (PM). Although several instruments are available to monitor PM, most require dilution air and are unable to sample directly from a flue due to the high PM concentrations and temperatures. Opacity sensors can measure color, opacity and smoke density from wood heater stacks. They operate by transmitting a light beam through the emission source and measuring the amount of light intensity lost (opacity) and light not reflected (color). Although opacity sensors are used in several areas, none have been thoroughly evaluated or optimized for measuring smoke from wood heaters.

47 OTHER INSTRUMENTATION↗

Implementation of Johnson Noise Thermometry into Radiation Hardened Electronics

The random motion of charge carriers in an electrical conductor is a function of its temperature. This phenomenon generates an electrical signal, referred to as Johnson noise, that is present in all analog signals. Conversely, the temperature dependence of the Johnson noise spectrum also enables a direct measurement of absolute temperature, which can provide a secondary measurement of temperature when quantified using sensors such as resistive temperature devices (RTDs) in a process called Johnson noise thermometry (JNT). For nuclear environments, this is of particular interest in correcting for RTDs signal drift caused by accumulation, transmutation, and displacement damage caused by neutron and gamma irradiation.

42 ENGINEERING↗

Development of An On-Line, Core Power Distribution Monitoring System

The objective of the proposed work was to develop a software package that can construct in three-dimensional core power distributions using the signals from constant temperature power sensors distributed in the reactor core. The software developed uses a mode-based state/parameter estmation technique that is particularly attractive when there are model uncertainties and/or large signal noise. The software yields the expected value of local power at the detector locations and points in between, as well as the probability distribution of the local power density

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Long Duration Testing of Type C Thermocouples at 1500 °C

Experience with Type C thermocouples operating for long periods in the 1400 to 1600 °C temperature range indicate that significant decalibration occurs, often leading to expensive downtime and material waste. As part of an effort to understand the mechanisms causing drift in these thermocouples, the Idaho National Laboratory conducted a long duration test at 1500 °C containing eight Type C thermocouples. As report in this document, results from this long duration test were adversely affected due to oxygen ingress. Nevertheless, results provide key insights about the impact of precipitate formation on thermoelectric response. Post-test examinations indicate that thermocouple signal was not adversely impacted by the precipitates detected after 1,000 hours of heating at 1,500 °C and suggest that the signal would not have been adversely impacted by these precipitates for longer durations (if oxygen ingress had not occurred in this test).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗