Search NASA⌕ Search

SEARCH · Search NASA

Results for “device packaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

RF MEMS Switches with SiC Microbridges for Improved Reliability

Radio frequency (RF) microelectromechanical (MEMS) switches offer superior performance when compared to the traditional semiconductor devices such as PIN diodes or GaAs transistors. MEMS switches have a return loss (RL) better than -25 dB, negligible insertion loss (IL), isolation better than -30 dB, and near zero power consumption. However, RF MEMS switches have several drawbacks the most serious being long-term reliability. The ability for the switch to operate for millions or even billions of cycles is a major concern and must be addressed. MEMS switches are basically grouped in two categories, capacitive and metal-to-metal contact. The capacitive type switch consists of a movable metal bridge spanning a fixed electrode and separated by a narrow air gap and thin insulating material. The metal-to-metal contact type utilizes the same basic design but without the insulating material. After prolonged operation the metal bridges, in most of these switches, begin to sag and eventually fail to actuate. For the metal-to-metal type, the two metal layers may actually fuse together. Also if the switches are not packaged properly or protected from the environment moisture may build up and cause stiction between the top and bottom electrodes rendering them useless. Many MEMS switch designs have been developed and most illustrate fairly good RF characteristics. Nevertheless very few have demonstrated both great RF performance and ability to perform millions/billions of switching cycles. Of these, nearly all are of metal-to-metal type so as the frequency increases RF performance decreases.

Scardelletti, Maximilian C.↗

Criticality Scoping Calculations for a Multi-Function Dissolver Insert

As one of its missions, the Savannah River Site seeks to be a leader in the safe and productive disposition of special nuclear materials. One of the premier programs is the disposition of used nuclear fuel, primarily from research reactors, through dissolution, purification, and down blend into low enriched uranium for commercial power reactors. Prior to use, this fuel contained highly enriched uranium (HEU). In an effort to advance this expertise, this study has been performed to demonstrate the feasibility to disposition a number of special geometry HEU fuels. These fuels come from a number of different domestic and foreign research reactors which had geometries considerably different from round or square bundles of plates or rods. As such, they cannot be dispositioned in current H-Canyon dissolver inserts so a new, multi-function dissolver insert may be considered. While this is not a current mission, it is believed that this study's scoping calculations demonstrate the feasibility of the site taking such a mission. At the H-Canyon facility, a dissolver is a large stainless steel pot, loaded with a nitric acid solution into which uranium-alloy fuel is dissolved. The dissolver uses a device called an insert to feed the fuels to the acid solution in a controlled manner. Most fuel forms fit into one of the existing inserts which include one with ten {approx}5-inch diameter circular wells, one with four {approx}4.5 inch by {approx}15 inch slab wells, and one specifically designed for the Oak Ridge National Laboratory High Flux Isotope Reactor (HFIR). This study considered five bounding fuel candidates for scoping the potential new insert. The fuels include a generic annular plate fuel (APF), the Tower Shield Reactor (TSR) fuel elements, the Reactor A Haute Flux (RHF) core, Knolls Atomic Power Laboratory (KAPL) reactor fuel, and SLOWPOKE cores. These are expected to bound a range of proposed fuel candidates. Scoping studies were made to establish geometric restrictions for the new dissolver insert and to determine if these fuels could safely be dissolved. Homogenous models were used for the scoping study due to time constraints. Computational modeling was performed using KENOVI in the SCALE 6.1 code package.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Single cell swimming dynamics of Listeria monocytogenes using a nanoporous microfluidic platform

Listeria monocytogenes remains a significant foodborne pathogen due to its virulence and ability to become established in food processing facilities. The pathogen is characterized by its ability to grow over a wide temperature range and withstand a broad range of stresses. The following reports on the chemotaxis and motility of the L. monocytogenes when exposed to relatively small concentrations of acetic acid. Using the developed nanoporous microfluidic device to precisely modulate the cellular environment, we exposed the individual Listeria cells to acetic acid and, in real time and with high resolution, observed how the cells reacted to the change in their surroundings. Our results showed that concentrations of acetic acid below 10 mM had very little, if any, effect on the motility. However, when exposed to 100 mM acetic acid, the cells exhibited a sharp drop in velocity and displayed a more random pattern of motion. These results indicate that at appropriate concentrations, acetic acid has the ability to disable the flagellum of the cells, thus impairing their motility. This drop in motility has numerous effects on the cell; its main effects being the obstruction of the cell's ability to properly form biofilms and a reduction in the overall infectivity of the cells. Since these characteristics are especially useful in controlling the proliferation of L. monocytogenes, acetic acid shows potential for application in the food industry as an active compound in designing a food packaging environment and as an antimicrobial agent.

Wright, Evan↗

Designing an autonomous environment for mission critical operation of the EUVE satellite

Since the launch of NASA's Extreme Ultraviolet Explorer (EUVE) satellite in 1992, there has only been a handful of occurrences that have warranted manual intervention in the EUVE Science Operations Center (ESOC). So, in an effort to reduce costs, the current environment is being redesigned to utilize a combination of off-the-shelf packages and recently developed artificial intelligence (AI) software to automate the monitoring of the science payload and ground systems. The successful implementation of systemic automation would allow the ESOC to evolve from a seven day/week, three shift operation, to a seven day/week one shift operation. First, it was necessary to identify all areas considered mission critical. These were defined as follows: (1) The telemetry stream must be monitored autonomously and anomalies identified. (2) Duty personnel must be automatically paged and informed of the occurrence of an anomaly. (3) The 'basic' state of the ground system must be assessed. (4) Monitors should check that the systems and processes needed to continue in a 'healthy' operational mode are working at all times. (5) Network loads should be monitored to ensure that they stay within established limits. (6) Connectivity to Goddard Space Flight Center (GSFC) systems should be monitored as well, not just for connectivity of the network itself but also for the ability to transfer files. (7) All necessary peripheral devices should be monitored. This would include the disks, routers, tape drives, printers, tape carousel, and power supplies. (8) System daemons such as the archival daemon, the Sybase server, the payload monitoring software, and any other necessary processes should be monitored to ensure that they are operational. (9) The monitoring system needs to be redundant so that the failure of a single machine will not paralyze the monitors. (10) Notification should be done by means of looking though a table of the pager numbers for current 'on call' personnel. The software should be capable of dialing out to notify, sending email, and producing error logs. (11) The system should have knowledge of when real-time passes and tape recorder dumps will occur and should know that these passes and data transmissions are successful. Once the design criteria were established, the design team split into two groups: one that addressed the tracking, commanding, and health and safety of the science payload and another group that addressed the ground systems and communications aspects of the overall system.

Abedini, Annadiana↗

Implementing Computer-Based Procedures: Thinking Outside the Paper Margins

In the past year there has been increased interest from the nuclear industry in adopting the use of electronic work packages and computer-based procedures (CBPs) in the field. The goal is to incorporate the use of technology in order to meet the Nuclear Promise requirements of reducing costs and improve efficiency and decrease human error rates of plant operations. Researchers, together with the nuclear industry, have been investigating the benefits an electronic work package system and specifically CBPs would have over current paper-based procedure practices. There are several classifications of CBPs ranging from a straight copy of the paper-based procedure in PDF format to a more intelligent dynamic CBP. A CBP system offers a vast variety of improvements, such as context driven job aids, integrated human performance tools (e.g., placekeeping and correct component verification), and dynamic step presentation. The latter means that the CBP system could only display relevant steps based on operating mode, plant status, and the task at hand. The improvements can lead to reduction of the worker’s workload and human error by allowing the work to focus on the task at hand more. A team of human factors researchers at the Idaho National Laboratory studied and developed design concepts for CBPs for field workers between 2012 and 2016. The focus of the research was to present information in a procedure in a manner that leveraged the dynamic and computational capabilities of a handheld device allowing the worker to focus more on the task at hand than on the administrative processes currently applied when conducting work in the plant. As a part of the research the team identified type of work, instructions, and scenarios where the transition to a dynamic CBP system might not be as beneficial as it would for other types of work in the plant. In most cases the decision to use a dynamic CBP system and utilize the dynamic capabilities gained will be beneficial to the worker. However, tasks that are reliant on the skill of the craft or have a short set of instructions may not provide a way or even need to utilize all the advanced capabilities in a dynamic CBP system. Therefore, a hybrid CBP system that could handle all the classifications of a CBP would be the best solution to take advantage of all that a CBP system offers. The implementation of a CBP system does not automatically improve the quality of procedures. Utilities should look into why each procedure is written the way it currently is on paper. Utilities should take the time before implementation to review, standardize format and update current procedures. Implementation of a CBP system can be a time to break out of traditional procedure writing processes and create new processes and procedures that take advantage of the capabilities a CBP system. This paper will summarize the research on CBPs and provide suggestions to take into consideration when implementing a CBP system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Developments in Performance and Portability for MadGraph5_aMC@NLO

Event generators simulate particle interactions using Monte Carlo techniques, providing the primary connection between experiment and theory in experimental high energy physics. These software packages, which are the first step in the simulation worflow of collider experiments, represent approximately 5 to 20% of the annual WLCG usage for the ATLAS and CMS experiments. With computing architectures becoming more heterogeneous, it is important to ensure that these key software frameworks can be run on future systems, large and small. In this contribution, recent progress on porting and speeding up the Madgraph5_aMC@NLO event generator on hybrid architectures, i.e. CPU with GPU accelerators, is discussed. The main focus of this work has been in the calculation of scattering amplitudes and "matrix elements", which is the computational bottleneck of an event generation application. For physics processes limited to QCD leading order, the code generation toolkit has been expanded to produce matrix element calculations using C++ vector instructions on CPUs and using CUDA for NVidia GPUs, as well as using Alpaka, Kokkos and SYCL for multiple CPU and GPU architectures. Performance is reported in terms of matrix element calculations per time on NVidia, Intel, and AMD devices. The status and outlook for the integration of this work into a production release usable by the LHC experiments, with the same functionalities and very similar user interfaces as the current Fortran version, is also described.

Valassi, Andrea↗

Macromolecular crystallography with a large format CMOS detector

Recent advances in CMOS technology have allowed the production of large surface area detectors suitable for macromolecular crystallography experiments [1]. The Molecular Biology Consortium (MBC) Beamline 4.2.2 at the Advanced Light Source in Berkeley, CA, has installed a 2952 x 2820 mm RDI CMOS-8M detector with funds from NIH grant S10OD012073. The detector has a 20nsec dead pixel time and performs well with shutterless data collection strategies. The sensor obtains sharp point response and minimal optical distortion by use of a thin fiber-optic plate between the phosphor and sensor module. Shutterless data collections produce high-quality redundant datasets that can be obtained in minutes. The fine-sliced data are suitable for processing in standard crystallographic software packages (XDS, HKL2000, D*TREK, MOSFLM). Faster collection times relative to the previous CCD detector have resulted in a record number of datasets collected in a calendar year and de novo phasing experiments have resulted in publications in both Science and Nature [2,3]. The faster collections are due to a combination of the decreased overhead requirements of shutterless collections combined with exposure times that have decreased by over a factor of 2 for images with comparable signal to noise of the NOIR-1 detector. The overall increased productivity has allowed the development of new beamline capabilities and data collection strategies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Imaging spectrophotometry of the nuclear outflow of NGC 1068

This observational program (in conjunction with R. B. Tully (IfA, Honolulu), and J. Bland (Rice U., Houston)) aims to constrain the kinematic organization and dominant excitation mechanisms of ionized gas in active galaxies. More generally, researchers are interested in the dynamics of radiative, supersonic flows in the Interstellar Medium (ISM). Imaging Fabry-Perot interferometers and low-noise Charge Coupled Devices (CCDs) are used for complete spatial coverage of the complex gas distribution in circumnuclear narrow-line regions (NLRs). Extranuclear emission line widths in NLRs can exceed 3000 km s(-1), so to avoid inter-order confusion researchers use an etalon of 4000 km s(-1) free spectral range to map (N II) lambda lambda 6548, 6583 and H alpha. To maximize spatial resolution, researchers select nearby active systems independent of luminosity but known to possess interesting morphologies and/or high-velocity extranuclear ionized gas. Monochromatic images Full Width Half Maximum (FWHM) approx. 65 km s(-1) have thus far been obtained in 1 second or better seeing at the U. Hawaii 2.2m, CFH 3.6m, and CTIO 4.0m telescopes. These are stacked into grids of line profiles, of spectrophotometric quality, at sub-arcsecond increments across a 3 second field. To handle the approx. 20,000 to 300,000 useful spectra that arise from a typical night's work, researchers have developed a complete analysis and reduction package for VAX and Sun image workstations. Reduction involves parametrization of approx. 10 to the 8th raw data points to a few maps (e.g., velocities of each kinematic subsystem, continuum-free line fluxes) containing approx. 10 to the 5th pixels. Researchers identify kinematic and structural symmetries by examining these maps and the point to point variations of the synthesized line profiles. The combination of monochromatic images and full spatial sampling of line profiles has allowed them to isolate such symmetries and has led to reliable kinematic deprojections.

Cecil, Gerald↗

THRIVE : a data reduction program for three-phase PDV/PDI and VISAR measurements.

THRIVE (THRee Interferometer VElocimetry) is an analysis package for reducing three-phase interferometry measurements. Three-phase displacement interferometry measurements are the primary application of this program, although velocity interferometry is also supported. THRIVE uses a push-pull approach to transform measured signals to a pair of quadrature signals, from which fringe shift, target position, and target velocity are inferred. The program can analyze the signals in an ideal sense or compensate for non-ideal measurement conditions using ellipse characterization. The program can be run in any current version of MATLAB (release 2007a or later) or as a Windows XP executable.

47 OTHER INSTRUMENTATION↗

Experimental evidence of colloids and nanoparticles presence from 25 waste leachates

Highlights: • This work is the first assessment of colloids in waste leachates. • Analytical methods are proposed and discussed. • All the waste have at least one element in colloidal form, and some elements are always colloidal. • Man-made nanoparticles are observed. • It can change the interpretation of leachate elemental concentration. - Abstract: The potential colloids release from a large panel of 25 solid industrial and municipal waste leachates, contaminated soil, contaminated sediments and landfill leachates was studied. Standardized leaching, cascade filtrations and measurement of element concentrations in the microfiltrate (MF) and ultrafiltrate (UF) fraction were used to easily detect colloids potentially released by waste. Precautions against CO{sub 2} capture by alkaline leachates, or bacterial re-growth in leachates from wastes containing organic matter should be taken. Most of the colloidal particles were visible by transmission electron microscopy with energy dispersion spectrometry (TEM–EDS) if their elemental MF concentration is greater than 200 μg l{sup −1}. If the samples are dried during the preparation for microscopy, neoformation of particles can occur from the soluble part of the element. Size distribution analysis measured by photon correlation spectroscopy (PCS) were frequently unvalid, particularly due to polydispersity and/or too low concentrations in the leachates. A low sensitivity device is required, and further improvement is desirable in that field. For some waste leachates, particles had a zeta potential strong enough to remain in suspension. Mn, As, Co, Pb, Sn, Zn had always a colloidal form (MF concentration/UF concentration > 1.5) and total organic carbon (TOC), Fe, P, Ba, Cr, Cu, Ni are partly colloidal for more than half of the samples). Nearly all the micro-pollutants (As, Ba, Co, Cr, Cu, Mo, Ni, Pb, Sb, Sn, V and Zn) were found at least once in colloidal form greater than 100 μg l{sup −1}. In particular, the colloidal forms of Zn were always by far more concentrated than its dissolved form. The TEM–EDS method showed various particles, including manufactured nanoparticles (organic polymer, TiO{sub 2}, particles with Sr, La, Ce, Nd). All the waste had at least one element detected as colloidal. The solid waste leachates contained significant amount of colloids different in elemental composition from natural ones. The majority of the elements were in colloidal form for wastes of packaging (3), a steel slag, a sludge from hydrometallurgy, composts (2), a dredged sediment (#18), an As contaminated soil and two active landfill leachates. These results showed that cascade filtration and ICP elemental analysis seems valid methods in this field, and that electronic microscopy with elemental detection allows to identify particles. Particles can be formed from dissolved elements during TEM sample preparation and cross-checking with MF and UF composition by ICP is useful. The colloidal fraction of leachate of waste seems to be a significant source term, and should be taken into account in studies of emission and transfer of contaminants in the environment. Standardized cross-filtration method could be amended for the presence of colloids in waste leachates.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of intermixing at CdS/CdTe interface on defect properties

We investigated the stability and electronic properties of defects in CdTe{sub 1−x}S{sub x} that can be formed at the CdS/CdTe interface. As the anions mix at the interface, the defect properties are significantly affected, especially those defects centered at cation sites like Cd vacancy, V{sub Cd}, and Te on Cd antisite, Te{sub Cd}, because the environment surrounding the defect sites can have different configurations. We show that at a given composition, the transition energy levels of V{sub Cd} and Te{sub Cd} become close to the valence band maximum when the defect has more S atoms in their local environment, thus improving the device performance. Such beneficial role is also found at the grain boundaries when the Te atom is replaced by S in the Te-Te wrong bonds, reducing the energy of the grain boundary level. On the other hand, the transition levels with respect to the valence band edge of CdTe{sub 1−x}S{sub x} increases with the S concentration as the valence band edge decreases with the S concentration, resulting in the reduced p-type doping efficiency.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modular 5-kW Power-Processing Unit Being Developed for the Next-Generation Ion Engine

The NASA Glenn Research Center is developing a 5- to 10-kW ion engine for a broad range of mission applications. Simultaneously, a 5-kW breadboard power-processing unit (PPU) is being designed and fabricated by Boeing Electron Dynamic Devices, Torrance, California, under contract with Glenn. The beam supply, which processes up to 90 percent of the power into this unit, consists of four 1.1-kW power modules connected in parallel, equally sharing the output current. The modular design allows scalability to higher powers as well as the possibility of implementing an N + 1 redundant beam supply. A novel phaseshifted/pulse-width-modulated, dual full-bridge topology was chosen for this module design for its efficient switching characteristics. A breadboard version of the beam power supply module was assembled. Efficiencies ranging between 91.6 and 96.9 percent were measured for an input voltage range of 80 to 160 V, an output voltage range of 800 to 1500 V, and output powers from 0.3 to 1.0 kW. This beam supply could result in a PPU with a total efficiency between 93 and 95 percent at a nominal input voltage of 100 V. This is up to a 4-percent improvement over the state-of-the-art PPU used for the Deep Space 1 mission. A flight-packaged PPU is expected to weigh no more than 15 kg, which represents a 50-percent reduction in specific mass from the Deep Space 1 design. This will make 5-kW ion propulsion very attractive for many planetary missions.

Pinero, Luis R.↗

Sandia Advanced MEMS Design Tools, Version 2.2.5

The Sandia National Laboratories Advanced MEMS Design Tools, Version 2.2.5, is a collection of menus, prototype drawings, and executables that provide significant productivity enhancements when using AutoCAD to design MEMS components. This release is designed for AutoCAD 2000i, 2002, or 2004 and is supported under Windows NT 4.0, Windows 2000, or XP. SUMMiT V (Sandia Ultra planar Multi level MEMS Technology) is a 5 level surface micromachine fabrication technology, which customers internal and external to Sandia can access to fabricate prototype MEMS devices. This CD contains an integrated set of electronic files that: a) Describe the SUMMiT V fabrication process b) Facilitate the process of designing MEMS with the SUMMiT process (prototype file, Design Rule Checker, Standard Parts Library) New features in this version: AutoCAD 2004 support has been added. SafeExplode ? a new feature that explodes blocks without affecting polylines (avoids exploding polylines into objects that are ignored by the DRC and Visualization tools). Layer control menu ? a pull-down menu for selecting layers to isolate, freeze, or thaw. Updated tools: A check has been added to catch invalid block names. DRC features: Added username/password validation, added a method to update the user?s password. SNL_DRC_WIDTH ? a value to control the width of the DRC error lines. SNL_BIAS_VALUE ? a value use to offset selected geometry SNL_PROCESS_NAME ? a value to specify the process name Documentation changes: The documentation has been updated to include the new features. While there exist some files on the CD that are used in conjunction with software package AutoCAD, these files are not intended for use independent of the CD. Note that the customer must purchase his/her own copy of AutoCAD to use with these files.

Yarberry, Victor↗

Comparison of different fractal dimension measuring algorithms for RE-TM M-O films

Noise in magneto-optical recording devices is discussed. In general, it appears that either the divider technique or amplitude spectrum technique may be used interchangeably to measure the fractal dimension (D) in the domain wall structure of ideal images. However, some caveats must be observed for best results. The divider technique is attractive for its simplicity and relatively modest computation requirements. However, it is sensitive to noise, in that noise pixels that touch the domain boundary are interpreted as being part of the boundary, skewing the measurement. Also, it is not useful in measuring nucleation-dominated films or domains that have significant amounts of structure within the interior of the domain wall. The amplitude spectrum method is more complex, and less intuitive than the divider method, and somewhat more expensive to implement computationally. However, since the camera noise tends to be white, the noise can be avoided in the measurement of D by avoiding that portion of the curve that is flat (due to the white noise) when the least squares line is fit to the plot. Also, many image processing software packages include a Fast Fourier Transformation (FFT) facility, while the user will most likely have to write his own edge extraction routine for the divider method. The amplitude spectrum method is a true two dimensional technique that probes the interior of the domain wall, and in fact, can measure arbitrary clusters of domains. It can also be used to measure grey-level images, further reducing processing steps needed to threshold the image.

Bernacki, Bruce E.↗

Modeling of particle transport, neutrals and radiation in magnetically-confined plasmas with Aurora

In this work, we present Aurora, an open-source package for particle transport, neutrals and radiation modeling in magnetic confinement fusion plasmas. Aurora's modern multi-language interface enables simulations of 1.5D impurity transport within high-performance computing frameworks, particularly for the inference of particle transport coefficients. A user-friendly Python library allows simple interaction with atomic rates from the Atomic Data and Atomic Structure database as well as other sources. This enables a range of radiation predictions, both for power balance and spectroscopic analysis. We discuss here the superstaging approximation for complex ions, as a way to group charge states and reduce computational cost, demonstrating its wide applicability within the Aurora forward model and beyond. Aurora also facilitates neutral particle analysis, both from experimental spectroscopic data and other simulation codes. Leveraging Aurora's capabilities to interface SOLPS-ITER results, we demonstrate that charge exchange is unlikely to affect the total radiated power from the ITER core during high performance operation. Finally, we describe the ImpRad module in the one modeling framework for integrated task framework, developed to enable experimental analysis and transport inferences on multiple devices using Aurora.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Novel Noise-Aware Classical Optimizer for Variational Quantum Algorithms

A key component of variational quantum algorithms (VQAs) is the choice of classical optimizer employed to update the parameterization of an ansatz. It is well recognized that quantum algorithms will, for the foreseeable future, necessarily be run on noisy devices with limited fidelities. Thus, the evaluation of an objective function (e.g., the guiding function in the quantum approximate optimization algorithm (QAOA) or the expectation of the electronic Hamiltonian in variational quantum eigensolver (VQE)) required by a classical optimizer is subject not only to stochastic error from estimating an expected value but also to error resulting from intermittent hardware noise. Model-based derivative-free optimization methods have emerged as popular choices of a classical optimizer in the noisy VQA setting, based on empirical studies. However, these optimization methods were not explicitly designed with the consideration of noise. In this work we adapt recent developments from the “noise-aware numerical optimization” literature to these commonly used derivative-free model-based methods. We introduce the key defining characteristics of these novel noise-aware derivative-free model-based methods that separate them from standard model-based methods. In conclusion, we study an implementation of such noise-aware derivative-free model-based methods and compare its performance on demonstrative VQA simulations to classical solvers packaged in scikit-quant.

classical optimizers↗

Hamilton: Flexible, Open Source $10 Wireless Sensor System for Energy Efficient Building Operation

Sensors for improving building performance are rapidly populating the market, driven in part by the drive to reduce greenhouse gas emissions resulting from energy production as well as improve the interior environment for healthy and more productive spaces. UC Berkeley has led wireless sensor development over the past 25 years (e.g., Telos mote), with the Hamilton (named after Alexander Hamilton on the US $10 bill) as the most recent. The Hamilton sensor was designed as a low-cost high-performance sensor that is modular and interoperable. The objective of the Hamilton project was to create, evaluate and establish the technological foundations for secure and easy to deploy building energy efficiency applications utilizing pervasive, low-cost wireless sensors integrated with traditional Building Management Systems (BMS), consumer-sector building components, and powerful data analytics. The project included iterative hardware design, incorporating a high-performance database (BTrDb, http://btrdb.io/), creating and iterating the development of secure data middleware (BOSSwave, WAVE/WAVEMQ), working with and pushing the development of an open-source tiny operating system RiotOS, and implementing and improving protocols such as Thread/OpenThread and TCP/IP. The hardware benefited from careful design to drive down the cost; the design included a System-on-a-Chip (SoC), chip antenna, single crystal and five passive components. Careful design of the operating system created a low-power design to enable a long life with small batteries. The hardware included several sensors: temperature, radiant temperature, relative humidity, magnetometer, accelerometer, and light, with an optional occupancy (Passive InfraRed) sensor. The project was the basis of several applications, both internal to the research team and other researchers and professionals at other institutions. Several applications used the sensor hardware as the basis for other complex devices. Other applications used the sensors to improve building performance through interoperating with the building Heating Ventilation and Air-Conditioning (HVAC) system, such as using occupancy and/or distributed temperature sensing to reduce HVAC zone energy while still providing thermal comfort and to reduce peak loads in small commercial buildings. We demonstrated cloud-based energy analytics, implemented a schedule and a Model Predictive Controller in a small commercial building to optimize HVAC energy, occupancy and electricity price. Initial integration of these technological innovations was performed through the creation of execution containers containing the WAVE agent and various driver, proxy, or building system function logic. The research added to the understanding of efficient sensor hardware, secure middleware, time-series data management (high performance database), efficient communication protocols, and interoperating with applications and building systems. The project showed the technical effectiveness and economic feasibility of creating a low-cost, modular, and easy-to-deploy sensor. Through conversations with multiple end users, the research team discovered that many customers wanted data management and services in addition to the sensors. HamiltonIOT developed packages of sensors, border router, and data services to provide a seamless “plug-and-play” sensor deployment. Some customers were willing to pay for higher quality sensors (such as light); some customers wanted a robust enclosure (waterproof).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

In-situ packaging ultra-uniform 3D hematite nanotubes by polyaniline and their improved gas sensing properties

Highlights: • Ultra-uniform 3D α-Fe{sub 2}O{sub 3} nanotubes were packaged by PANI through the two-stage solution processes. • PANI/α-Fe{sub 2}O{sub 3}-based sensor could detect low concentration of acetone (1 ppm) at lower temperature of 180 °C. • The unique structure of α-Fe{sub 2}O{sub 3} support and its synergetic effect with PANI layers improved the sensor performances. - Abstract: This paper reports the PANI (polyaniline)-packaged three-dimensional (3D) α-Fe{sub 2}O{sub 3} nanotubes P/N heterojunction, which was constructed successfully though a facile hydrothermal reaction without adding any surfactant followed by in-situ chemical polymerization in the liquid phase. The structure and morphology of the products were characterized by means of FESEM, XRD, TEM & HRTEM, TGA and FT-IR. Gas sensing test results found that, the PANI/α-Fe{sub 2}O{sub 3} nanocomposite sensor exhibited obviously higher response, lower working temperature (180 °C), fast response and recovery speeds, good selectivity and excellent stability to acetone gas, indicating its promising application for high-performance acetone sensors. The enhanced gas sensing performances can be attributed to the factors like ultra-uniform 3D nanotube-like structure for α-Fe{sub 2}O{sub 3}, the noticeable advantages of PANI, as well as the construction of heterojunction barrier at their interface. The as-prepared PANI/α-Fe{sub 2}O{sub 3} nanocomposite may be also applied in other areas like photocatalysis, water purification, ion batteries, optical devices, and so on.

77 NANOSCIENCE AND NANOTECHNOLOGY↗