Search NASA⌕ Search

SEARCH · Search NASA

Results for “group testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

OMS FDIR: Initial prototyping

The Space Station Freedom Program (SSFP) Operations Management System (OMS) will automate major management functions which coordinate the operations of onboard systems, elements and payloads. The objectives of OMS are to improve safety, reliability and productivity while reducing maintenance and operations cost. This will be accomplished by using advanced automation techniques to automate much of the activity currently performed by the flight crew and ground personnel. OMS requirements have been organized into five task groups: (1) Planning, Execution and Replanning; (2) Data Gathering, Preprocessing and Storage; (3) Testing and Training; (4) Resource Management; and (5) Caution and Warning and Fault Management for onboard subsystems. The scope of this prototyping effort falls within the Fault Management requirements group. The prototyping will be performed in two phases. Phase 1 is the development of an onboard communications network fault detection, isolation, and reconfiguration (FDIR) system. Phase 2 will incorporate global FDIR for onboard systems. Research into the applicability of expert systems, object-oriented programming, fuzzy sets, neural networks and other advanced techniques will be conducted. The goals and technical approach for this new SSFP research project are discussed here.

Taylor, Eric W.↗

WISE-2005 Protective Effect of Exercise within LBNP Countermeasure Detected by Heart Rate Response to Low Levels of LBNP

Sixteen women were studied before, during and after a 60 day, continu ous 6" head-down bed-rest (HDBR). Subjects were randomly assigned to two groups: Control (no countermeasures) and Exercise+LBNP (supine ru nning within an LBNP chamber for 40-min followed by 10-min passive L BNP for 3-4 days/week, plus flywheel resistive training of the legs e very third day). Cardiovascular responses were observed before bed re st, on day 50 of HDBR and R+8 after bed rest. Subjects were supine in the LBNP device with suction applied at 0, -10, -20 and -30 mmHg LBN P for 2-min per stage. In the pre-bed rest testing, there was no diff erence in HR between the groups at rest or at -30 mmHg. On HDBR day 50, HR was elevated at supine rest for the Con not the Ex group, whil e at -30 mmHg HR was elevated above pre-HDBR for both groups, but the magnitude of increase from Pre- to HDBR day 50 was less for the Ex g roup than for the Con group. The change in HR on HDBR day 50 is an im portant indicator as it was less than 24-hours after the Exercise+LBN P countermeasure on day 49. After bed rest, no specific countermeasu res were provided in the first week, so HR responses on day R+8 refle cted the effects of bed rest with or without countermeasure plus any recovery from simply returning to the upright posture. Relative to th e Pre-bed rest responses, HR on day R+8 had recovered in the Ex group but was still elevated in the Con group. These results indicate that the cardiovascular response to LBNP is preserved to a greater degre e during bed rest by the countermeasures, and further that the cardio vascular response returned to pre-bed rest much more rapidly in the E xercise+LBNP group than hi the group that received no cardiovascular countermeasures.

Hughson, R. L.↗

Space Flight LiDARs, Navigation & Science Instrument Implementations: Lasers, Optoelectronics, Integrated Photonics, Fiber Optic Subsystems and Components

For the past 25 years, the National Aeronautics and Space Administration (NASA) Goddard Space Flight Center's Photonics Group in the Engineering Directorate has been substantially contributing to the flight design, development, production, testing and integration of many science and navigational instruments. The Moon to Mars initiative will rely heavily upon utilizing commercial technologies for instrumentation with aggressive schedule deadlines. The group has an extensive background in screening, qualifying, development and integration of commercial components for spaceflight applications. By remaining adaptable and employing a rigorous approach to component and instrument development, they have forged and fostered relationships with industry partners. They have been willing to communicate lessons learned in packaging, part construction, materials selection, testing, and other facets of the design and production process critical to implementation for high-reliability systems. As a result, this successful collaboration with industry vendors and component suppliers has enabled a history of mission success from the Moon to Mars (and beyond) while balancing cost, schedule, and risk postures. In cases where no commercial components exist, the group works closely with other teams at Goddard Space Flight Center and other NASA field centers to fabricate and produce flight hardware for science, remote sensing, and navigation applications. Summarized here is the last ten years of instrumentation development lessons learned and data collected from the subsystems down to the optoelectronic component level.

Detectors↗

Fibre Channel Development Final Report CRADA No. TC-0340-92-D

The Fibre Channel (FC) Development project was designed to enhance U.S. industrial competitiveness by accelerating the standardization and subsequent industrial acceptance of the American National Standards Institute’s (AIW) Fibre Channel Standard (now X3T1 1). It was also intended to give the principal U.S. participants a one- to two-year lead in developing heterogeneous high-speed computer networks, dktibuted computing through clustering, scientific visualization techniques, and high speed channels. The project was proposed to benefit U.S. industry as these high performance computing methods became generally available. In 1992-93, during the initial project phases, Fibre Channel PC) was emerging as a new ANSI standard. It was envisioned as becoming the mechanism for data transfer between the next generation of computers, and between these computers and their peripherals. Using this channel standard, U.S. computer vendors were expecting to be able to provide high-speed interoperability between heterogeneous computers and their storage devices, with data transfer rates greater than a GBit/sec. Our project was composed of key principal players in the FC standardization effort from both U.S. industry and the Department of Energy’s (DOES) Lawrence Liverrnore National Laboratory (LLNL). The industial participants were developing individual FC interfaces to operate with their platform products. LLNL’s role was to be a neutral testing site and a facilitator for helping to resolve conflicting interpretations of the embryonic Fibre Channel specification. LLNL anticipated that conflicts in the interpretation of such a standard would arise and require neutral resolution and that such resolutions would best be achieved in cooperation with the ANSI FC Working Group. Project plans included transferring to U.S. industry any resilient FC testing capabilities at the project conclusion.

42 ENGINEERING↗

Fibre Channel Development Final Report CRADA No. TC-0340-92-C

The Fibre Channel (FC) Development project was designed to enhance U.S. industrial competitiveness by accelerating the standardization and subsequent industrial acceptance of the American National Standards Institute’s (ANSI) Fibre Channel Standard (now X3T1 1). It was also intended to give the principal U.S. participants a one-to two-year lead in developing heterogeneous high-speed computer networks, distributed computing through clustering, scientific visualization techniques, and high speed channels. The project was proposed to benefit U.S. industry as these high performance computing methods became generally available. In 1992-93, during the initial project phases, Fibre Channel (FC) was emerging as a new ANSI standard. It was envisioned as becoming the mechanism for data transfer between the next generation of computers, and between these computers and their peripherals. Using this channel standard, U.S. computer vendors were expecting to be able to provide high-speed interoperatillity between heterogeneous computers and their storage devices, with data transfer rates greater than a GBit/sec. Our project was composed of key principal players in the FC standardization effort from both U.S. industry and the Department of Energy’s@OEs) Lawrence Liverrnore National Laboratory (LLNL). The industrial participants were developing individual FC interfaces to operate with their platform products. LLNL’s.role was to be a neutral testing site and a facilitator for helping to resolve conflicting interpretations of the embryonic Fibre Channel specification. LLNL anticipated that conflicts in the interpretation of such a standard would arise and require neutral resolution and that such resolutions would best be achieved in cooperation with the ANSI FC Working Group. Project plans included transferring to U.S. industry any resilient FC testing capabilities at the project conclusion.

42 ENGINEERING↗

Comparative Soot Diagnostics: Preliminary Results

The motivation for the Comparative Soot Diagnostics (CSD) experiment lies in the broad practical importance of understanding combustion generated particulate. Depending upon the circumstances, particulate matter can affect the durability and performance of combustion equipment, can be a pollutant, can be used to detect fires and, in the form of soot, can be the dominant source of radiant energy from flames. The nonbuoyant structure of most flames of practical interest makes understanding of soot processes in low gravity flames important to our ability to predict fire behavior on earth. These studies also have direct applications to fire safety in human-crew spacecraft, since smoke is the indicator used for automated detection in current spacecraft. In the earliest missions (Mercury, Gemini and Apollo), the crew quarters were so cramped that it was considered reasonable that the astronauts would rapidly detect any fire. The Skylab module, however, included approximately 20 UV-sensing fire detectors. The Space Shuttle has 9 particle-ionization smoke detectors in the mid-deck and flight deck and Spacelab has six additional particle-ionization smoke detectors. The designated detectors for the ISS are laser-diode, forward-scattering, smoke or particulate detectors. Current plans for the ISS call for two detectors in the open area of the module, and detectors in racks that have both cooling air flow and electrical power. Due to the complete absence of data concerning the nature of particulate and radiant emission from incipient and fully developed low-g fires, all three of these detector systems were designed based upon l-g test data and experience. As planned mission durations and complexity increase and the volume of spacecraft increases, the need for and importance of effective, crew-independent, fire detection grows significantly. To provide this level of protection, more knowledge is needed concerning low-gravity fire phenomena and, in particular, how they might be detected and suppressed. Prior to CSD, no combustion-generated particulate samples had been collected near the flame zone for well-developed microgravity flames. All of the extant data either came from drop tower tests and therefore only corresponded to the early stages of a fire or were collected far from the flame zone. The fuel sources in the drop tower tests were restricted to laminar gas-jet diffusion flames and very rapidly overheated wire insulation. The gas-jet tests indicated, through thermophoretic sampling, (2) that soot primaries and aggregates (groups of primary particles) in low-gravity may be significantly larger than those in normal gravity (1-g). This raises new scientific questions about soot processes as well as practical issues for particulate size sensitivity and detection alarm threshold levels used in on-orbit smoke detectors. Preliminary tests in the 2.2 second drop tower suggest that particulate generated by overheated wire insulation may be larger in low-g than in 1-g. Transmission Electron Microscope (TEM) grids downstream of the fire region in the Wire Insulation Flammability experiment as well as visual observation of long string-like aggregates, further confirm this suggestion. The combined impact of these limited results and theoretical predictions is that, as opposed to extrapolation from l-g data, direct knowledge of low-g combustion particulate is needed for more confident design of smoke detectors for spacecraft. This paper describes the operation and preliminary results of the CSD, a project conceived and developed at NASA Lewis Research Center. The CSD flight experiment was conducted in the Middeck Glovebox Facility (MGBX) on USMP-3. The project is support by NASA Headquarters Microgravity Science and Applications Division and Code Q. The results presented here are from the microgravity portion of the experiment, including the temporal response of the detectors and average sizes of the primary and aggregate particles captured on the thermophoretic probes.

Urban, David L.↗

Alkyl Substitution Effect on Oxidation Stability of Sulfone-Based Electrolytes

Organic sulfone compounds have been widely used as high-voltage electrolytes for lithium-ion batteries for decades. However, owing to the complexity of the synthesis of new sulfones, only a few commercially available sulfones have been studied. In this paper, we report the synthesis of new sulfone compounds with various substituent groups and the impact of the substituent group on the oxidation stability of sulfones. Electrochemical floating tests using a 5 V LiNi0.5Mn1.5O4 spinel cathode and density functional theory calculations showed that the cyclopentyl-substituted sulfone McPS suffered from oxidation instability, starting from 4.9 V versus Li+/Li, as observed by the large leakage currents. On the other hand, the isopropyl-substituted sulfone MiPS and tetramethylene substituted sulfone TMS showed much improved oxidation stability under identical testing conditions. The substitution structure of the sulfone plays a significant role in the determination of its oxidative stability and should first be considered for the development of new sulfone-based electrolytes for high-voltage, high-energy lithium-ion batteries.

alkyl substitution↗

Effect of Specimen Thickness on Fracture Toughness and Plane Stress to Plane Strain Transition in Medium-Density Polyethylene

This study investigates the effect of specimen thickness on fracture toughness and the transition from plane stress to plane strain conditions in Medium-Density Polyethylene (MDPE) using Single Edge Notched Bend (SENB) specimens. Three thickness groups (7.5 mm, 9.0 mm, and 12.1 mm) were tested following ASTM D5045 protocol. Conditional stress intensity factors (KQ) increased from 2.2 MPavm to 2.8 MPavm with increasing thickness, demonstrating significant size dependency. Confocal microscopy revealed a 34% reduction in maximum crack tip opening displacement (CTOD) from 0.478 mm to 0.314 mm as thickness increased, with plastic zone lateral extent decreasing by 32%. This quantitative evidence validates Irwin's theoretical prediction of plastic zone size transition from plane stress r_y˜ (1/2p) (K_I/s_y )^2 to plane strain conditions r_y˜ (1/6p) (K_I/s_y )^2.Scanning electron microscopy confirmed progressive suppression of shear lips and evolution from ductile tearing with extensive polymer chain drawing in thin specimens to localized crazing in thick specimens. Despite all specimens satisfying the ASTM D5045 criterion (B = 2.5(KQ/s_y )^2 ) ,residual shear lips persisted even in the thickest specimens, demonstrating that nominal size requirements alone are insufficient for achieving complete plane strain conditions in highly ductile polymers. The findings emphasize the necessity of integrated analytical and morphological assessment for valid fracture toughness characterization, with critical implications for life assessment and integrity prediction in thick-section polymer components such as natural gas distribution pipelines.

Medium-Density Polyethylene↗

The Dose-Volume Relationship of Small Bowel Irradiation and Acute Grade 3 Diarrhea During Chemoradiotherapy for Rectal Cancer

Purpose: Previous work has found a highly significant relationship between the irradiated small-bowel volume and development of Grade 3 small-bowel toxicity in patients with rectal cancer. This study tested the previously defined parameters in a much larger group of patients. Methods and Materials: A total of 96 consecutive patients receiving pelvic radiation therapy for rectal cancer had treatment planning computed tomographic scans with small-bowel contrast that allowed the small bowel to be outlined with calculation of a small-bowel dose-volume histogram for the initial intended pelvic treatment to 45 Gy. Patients with at least one parameter above the previously determined dose-volume parameters were considered high risk, whereas those with all parameters below these levels were low risk. The grade of diarrhea and presence of liquid stool was determined prospectively. Results: There was a highly significant association with small-bowel dose-volume and Grade 3 diarrhea (p {<=} 0.008). The high-risk and low-risk parameters were predictive with Grade 3 diarrhea in 16 of 51 high-risk patients and in 4 of 45 low-risk patients (p = 0.01). Patients who had undergone irradiation preoperatively had a lower incidence of Grade 3 diarrhea than those treated postoperatively (18% vs. 28%; p = 0.31); however, the predictive ability of the high-risk/low-risk parameters was better for preoperatively (p = 0.03) than for postoperatively treated patients (p = 0.15). Revised risk parameters were derived that improved the overall predictive ability (p = 0.004). Conclusions: The highly significant dose-volume relationship and validity of the high-risk and low-risk parameters were confirmed in a large group of patients. The risk parameters provided better modeling for the preoperative patients than for the postoperative patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Outcome With Neck Dissection After Chemoradiation for N3 Head-and-Neck Squamous Cell Carcinoma

Purpose: To evaluate the role of neck dissection (ND) after chemoradiation therapy (CRT) for head and neck squamous cell carcinoma (HNSCC) with N3 disease. Methods and Materials: From March 1998 to September 2006, 70 patients with HNSCC and N3 neck disease were treated with concomitant CRT as primary therapy. Response to treatment was assessed using clinical examination and computed tomography 6 to 8 weeks posttreatment. Neck dissection was not routinely performed and considered for those with less than complete response. Of the patients, 26 (37.1%) achieved clinical complete response (cCR) after CRT. A total of 31 (44.3%) underwent ND after partial response (cPR-ND). Thirteen patients (29.5%) did not achieve cCR and did not undergo ND for the following reasons: incomplete response/progression at primary site, refusal/contraindication to surgery, metastatic progression, or death. These patients were excluded from the analysis. Outcomes were computed using Kaplan-Meier curves and were compared with log rank tests. Results: Comparing the cCR and cPR-ND groups at 2 years, the disease-free survival was respectively 62.7% and 84.9% (p = 0.048); overall survival was 63.0% and 79.4% (p = 0.26), regional relapse-free survival was 87.8% and 96.0% (p = 0.21); and distant disease-free survival was 67.1% and 92.6% (p = 0.059). In the cPR-ND group, 71.0% had no pathologic evidence of disease (PPV of 29.0%). Conclusions: Patients with N3 disease achieving regional cPR and primary cCR who underwent ND seemed to have better outcomes than patients achieving global cCR without ND. Clinical assessment with computed tomography is not adequate for evaluating response to treatment. Because of the inherent limitations of our study, further confirmatory studies are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetization distribution in Cu 0.6 Mn 2.4 Ge 2 ferromagnet from polarized and non-polarized neutron powder diffraction aided by density-functional theory calculations

The crystal structure and magnetic properties of Cu 0.6 Mn 2.4 Ge 2 have been re-investigated by a combination of extensive magnetic measurements and neutron scattering experiments, aided by electronic structure calculations. The material is found to be a soft ferromagnet with the ordering temperature T C = 316 K. The magnetocaloric effect evaluated from field-dependent magnetization isotherms is equal to 1.2 J/(kg·K) and 2.5 J/(kg·K) under the maximum applied magnetic field of 2 T and 5 T, respectively. The compound crystallizes in the hexagonal space group P6 3 /mmc. A complex structural disorder necessitated testing of several disorder models against the results of non-polarized and polarized neutron scattering experiments and magnetization measurements. Simulations at the density-functional theory level were also performed to identify the most robust solution that properly described the data observed. The final magnetic structure model reveals non-equal magnetic moments on the Mn1 and Mn2 atoms (2.29(9) µ B and 2.7(1) µ B , respectively) and the presence of vacancies and minor Cu substitution defects in both Mn sites. The work demonstrates how the non-polarized and polarized neutron scattering methods can be combined with electronic structure calculations to establish the microscopic structure of magnetic materials with complex crystallographic disorder.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of 3D pixel silicon sensors for the CMS Phase-2 Inner Tracker

The high-luminosity upgrade of the CERN LHC requires the replacement of the CMS tracking detector to cope with the increased radiation fluence while maintaining its excellent performance. An extensive R&D program, aiming at using 3D pixel silicon sensors in the innermost barrel layer of the detector, has been carried out by CMS in collaboration with the FBK (Trento, Italy) and CNM (Barcelona, Spain) foundries. The sensors will feature a pixel cell size of 25 × 100 µm 2 , with a centrally located electrode connected to the readout chip. The sensors are read out by the RD53A and CROCv1 chips, developed in 65 nm CMOS technology by the RD53 Collaboration, a joint effort between the ATLAS and CMS groups. This paper reports the results achieved in beam test experiments before and after irradiation, up to a fluence of approximately 2 . 6 × 1 0 16 n eq /cm 2 . Measurements of assemblies irradiated to a fluence of 1 × 10 16 n˙eq/cm 2 show a hit detection efficiency higher than 96% at normal incidence, with fewer than 2% of channels masked, across a bias voltage range greater than 50 V . Even after irradiation to a higher fluence of 1.6 × 10 16 n˙eq/cm 2 , similar performance is maintained over a bias voltage range of 30 V , remaining well within CMS requirements.

3D pixel↗

Dinitrogen Binding and Functionalization from a Low-Coordinate Alkynyliron Complex

Alkynyl complexes of low-coordinate transition metals offer a sterically open environment and interesting bonding opportunities. Here, in this work, we explore the capacity of iron(I) alkynyl complexes to bind N 2 and isolate a N 2 complex including its X-ray crystal structure. Silylation of the N 2 complex gives an isolable, formally iron(IV) complex with a disilylhydrazido(2−) ligand, but natural bond orbital analysis indicates that an iron(II) formulation is preferable. The structure of this compound is similar to an earlier reported phenyl complex in which phenyl migration forms a new N–C bond, but the alkynyl group does not migrate. DFT calculations are used to test the possible reasons why the alkynyl is resistant to migration, and these show that the large Fe–C bond energy in the alkynyl complex is a factor that could contribute to the lack of migration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low-Dimensional Magnetic Semimetal Cr 0.65 Al 1.35 Se 3

While exploring novel magnetic semiconductors, the new phase Cr 0.65 Al 1.35 Se 3 was discovered and characterized by both structural and physical properties. Cr 0.65 Al 1.35 Se 3 was found to crystallize into orthorhombic CrGeTe 3 -type structure with space group Pnma (no. 62). Vacancies and mixed occupancies were tested, and the results show that one of the 4 c sites accommodates a mixture of Cr and Al atoms, while the other 4 c site is fully occupied by Al atoms. Unique structural features include a T-shaped channel network created from the edge-sharing Cr/Al@Se 6 and Al@Se 4 polyhedra and a zipper effect of the puckered Se atoms inside the columnar channels. The round peak observed in the temperature-dependent magnetic susceptibility (χ g ) plot at ~8(1) K corresponds to the antiferromagnetic-type transition in Cr 0.65 Al 1.35 Se 3 . Yet, the positive θ CW indicates an additional ferromagnetic interaction, which is highly likely due to the complex magnetic structure arising from the mixed Cr/Al occupancies on the 4 c site. Electrical resistivity measurements confirm that Cr 0.65 Al 1.35 Se 3 is a semimetal with a positive magnetoresistance. In this work, we present the characterization and determination of the crystal structure and physical properties for this new material.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

VARIATIONS IN THE MASS FUNCTIONS OF CLUSTERED AND ISOLATED YOUNG STELLAR OBJECTS

We analyze high-quality, complete stellar catalogs for four young (roughly 1 Myr) and nearby (within {approx}300 pc) star-forming regions: Taurus, Lupus3, ChaI, and IC348, which have been previously shown to have stellar groups whose properties are similar to those of larger clusters such as the Orion Nebula Cluster (ONC). We find that stars at higher stellar surface densities within a region or belonging to groups tend to have a relative excess of more massive stars, over a wide range of masses. We find statistically significant evidence for this result in Taurus and IC348 as well as in the ONC. These differences correspond to having typically a {approx}10%-20% higher mean mass in the more clustered environment. Stars in ChaI show no evidence for a trend with either surface density or grouped status, and there are too few stars in Lupus3 to make any definitive interpretation. Models of clustered star formation do not typically extend to sufficiently low masses or small group sizes in order for their predictions to be tested, but our results suggest that this regime is important to consider.

79 ASTRONOMY AND ASTROPHYSICS↗

Asymmetry of the dimension-two gluon condensate: The zero temperature case

We provide an algebraic study of the local composite operators A{sub {mu}}A{sub {nu}}-({delta}{sub {mu}}{sub {nu}}/d)A{sub {kappa}}{sup 2} and A{sub {mu}}{sup 2}, with d=4 the spacetime dimension. We prove that these are separately renormalizable to all orders in the Landau gauge. This corresponds to a renormalizable decomposition of the operator A{sub {mu}}A{sub {nu}} into its trace and traceless parts. We present explicit results for the relevant renormalization group functions to three loop order, accompanied by various tests of these results. We then develop a formalism to determine the zero temperature effective potential for the corresponding condensates, and recover the already known result for <A{sub {mu}}{sup 2}>{ne}0, together with <A{sub {mu}}A{sub {nu}}-({delta}{sub {mu}}{sub {nu}}/d)A{sub {kappa}}{sup 2}>=0, a nontrivial check that the approach is consistent with Lorentz symmetry. The formalism is such that it is readily generalizable to the finite temperature case, which shall allow a future analytical study of the electric-magnetic symmetry of the <A{sub {mu}}{sup 2}> condensate, which received strong evidence from recent lattice simulations by Chernodub and Ilgenfritz, who related their results to three regions in the Yang-Mills phase diagram.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Towards the minimal spectrum of excited baryons

In the light baryon sector the resonances can be broad and overlapping and are in most cases not directly visible in the cross section data. Automatized model selection techniques that introduce penalties for choosing particular resonance sets can be used to determine the minimally needed set of resonances to describe the data. Several possible penalization schemes for the occurrence of resonances are compared. As an application we perform a blindfold identification of hyperon resonances in the $\bar{K}$ N → K $\Xi$ reaction based on the Least Absolute Shrinkage and Selection Operator (LASSO) in combination with the Bayesian Information Criterion (BIC). Here, we find ten resonances - out of the 21 above-threshold hyperon resonances with spin J ≤ 7/2 listed by the Particle Data Group. In traditional analyses, it is practically impossible to test the relevance of all resonances and their combinations that may potentially contribute to the reaction. By contrast, the present method proves capable of determining the relevant resonances among a relatively large pool of candidates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-T-474: IMRT Verification Using the On-Board EPID

Purpose: To verify IMRT and Rapid Arc (RA) plan's agreement with treatment delivery for radiation therapy using an on-board EPID compared to MapCHECK2 and ArcCHECK. Methods: On-board EPID (Exact arm) is commissioned using manufacturer's Preconfigured Data Input Package (PDIP). Portal dose calculation engine for comparison with measurement was commissioned with PDIP. The absolute dosimetric calibration of the EPID is performed using 10×10cm field size at 105cm source to image detector distance with 90.7 CU in the integrated mode. The dark and flood field of EPID were also calibrated in the integrated mode for all energies and dose rates. The output dose-response data from the manufacturer was verified. The improved gamma test method was used for EPID data analysis. Gamma test were used for MapCHECK2 (or ArcCHECK). The sensitivity of the method was tested using collimator rotation at 3 degree and 5 degree. Student T-test was used to distinguish the difference among the groups. Results: IMRT: The average of Gamma passing rate using EPID and MapCHECK2 is 98.9±1.6% and 98.7±2.0% (p = 0.342). There is no statistical difference between two groups.RA: The average of Gamma passing rate using EPID and ArcCHECK is 97.2±2.3% and 93.2±4.1%. (p = 0.002). EPID significantly improved the RapidARC plan passing rate compared to the ArcCHECK. 5% dose change typically causes between 3 – 55% change in Gamma. Conclusion: Using the EPID, we were able to perform QA verification on IMRT plans comparable to MapCHECK2 (p=0.342) and superior to that of ArcCHECK (p=0.002) using Gamma 3%, 3mm criteria. The sensitivity of EPID was found to be comparable to that of the MapCHECK2 and ArcCHECK. EPID dosimetry is faster (4.3 mins vs. 10 mins) due to easier setup and integrated data processing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗