Search NASA⌕ Search

SEARCH · Search NASA

Results for “scan pattern”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Structural and transport properties of CdSe nanorods

The nanorods of cadmium selenide (CdSe) have been synthesized by soft chemical route. The selected area electron diffraction pattern, high resolution TEM and X-ray diffraction pattern indicate the cubic structure of the sample. The band gap of the sample is obtained using Tauc relation to UV-visible spectrum and found to be 1.92 eV. 1{sup st} order and 2{sup nd} order Raman bands are followed to investigate the behaviour of the phonon modes of the materials which is considered to be important to predict the potential of the material to microwave applications. Thermal behaviour of the sample is investigated using differential scanning calorimeter. Kissinger equation is used to calculate the activation energy of the sample, which is found to be 1.67 eV.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Diffractive Multiplexing for High-Throughput Roll-to-Roll Laser Patterning of Flexible Organic Photovoltaic Modules (Final Report)

The purpose of this project is to demonstrate a cost-effective, high-throughput roll-to-roll (R2R) process for patterning of flexible, semitransparent organic photovoltaic (OPV) modules by developing diffractive optics-based laser multiplexing (DOL Multiplexing). DOL Multiplexing allows a single, high-powered laser source to perform parallel scribing across the R2R web width in a manner compatible with high process speeds. Such a process could have enormous benefits in terms of increased process speeds and reduced costs, both up-front capital costs, and long-term operational costs, over galvanometer-based step and scan methods or many-laser systems.

14 SOLAR ENERGY↗

A limited-angle intrafraction verification (LIVE) system for radiation therapy

Purpose: Currently, no 3D or 4D volumetric x-ray imaging techniques are available for intrafraction verification of target position during actual treatment delivery or in-between treatment beams, which is critical for stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) treatments. This study aims to develop a limited-angle intrafraction verification (LIVE) system to use prior information, deformation models, and limited angle kV-MV projections to verify target position intrafractionally. Methods: The LIVE system acquires limited-angle kV projections simultaneously during arc treatment delivery or in-between static 3D/IMRT treatment beams as the gantry moves from one beam to the next. Orthogonal limited-angle MV projections are acquired from the beam's eye view (BEV) exit fluence of arc treatment beam or in-between static beams to provide additional anatomical information. MV projections are converted to kV projections using a linear conversion function. Patient prior planning CT at one phase is used as the prior information, and the on-board patient volume is considered as a deformation of the prior images. The deformation field is solved using the data fidelity constraint, a breathing motion model extracted from the planning 4D-CT based on principal component analysis (PCA) and a free-form deformation (FD) model. LIVE was evaluated using a 4D digital extended cardiac torso phantom (XCAT) and a CIRS 008A dynamic thoracic phantom. In the XCAT study, patient breathing pattern and tumor size changes were simulated from CT to treatment position. In the CIRS phantom study, the artificial target in the lung region experienced both size change and position shift from CT to treatment position. Varian Truebeam research mode was used to acquire kV and MV projections simultaneously during the delivery of a dynamic conformal arc plan. The reconstruction accuracy was evaluated by calculating the 3D volume percentage difference (VPD) and the center of mass (COM) difference of the tumor in the true on-board images and reconstructed images. Results: In both simulation and phantom studies, LIVE achieved substantially better reconstruction accuracy than reconstruction using PCA or FD deformation model alone. In the XCAT study, the average VPD and COM differences among different patient scenarios for LIVE system using orthogonal 30° scan angles were 4.3% and 0.3 mm when using kV+BEV MV. Reducing scan angle to 15° increased the average VPD and COM differences to 15.1% and 1.7 mm. In the CIRS phantom study, the VPD and COM differences for the LIVE system using orthogonal 30° scan angles were 6.4% and 1.4 mm. Reducing scan angle to 15° increased the VPD and COM differences to 51.9% and 3.8 mm. Conclusions: The LIVE system has the potential to substantially improve intrafraction target localization accuracy by providing volumetric verification of tumor position simultaneously during arc treatment delivery or in-between static treatment beams. With this improvement, LIVE opens up a new avenue for margin reduction and dose escalation in both fractionated treatments and SRS and SBRT treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Melanin Concentration Gradients in Modern and Fossil Feathers

In birds and feathered non-avian dinosaurs, within-feather pigmentation patterns range from discrete spots and stripes to more subtle patterns, but the latter remain largely unstudied. A ,55 million year old fossil contour feather with a dark distal tip grading into a lighter base was recovered from the Fur Formation in Denmark. SEM and synchrotron-based trace metal mapping confirmed that this gradient was caused by differential concentration of melanin. To assess the potential ecological and phylogenetic prevalence of this pattern, we evaluated 321 modern samples from 18 orders within Aves. We observed that the pattern was found most frequently in distantly related groups that share aquatic ecologies (e.g. waterfowl Anseriformes, penguins Sphenisciformes), suggesting a potential adaptive function with ancient origins.

59 BASIC BIOLOGICAL SCIENCES↗

Artificial Intelligence for Accelerating Nuclear Applications, Science, and Technology

Artificial intelligence (AI) and machine learning (ML) methods have had significant impacts in science and technology in recent years. These methods for generating models from datasets or logic-based algorithms that emulate aspects of human performance can similarly accelerate the fields of nuclear applications, science, and technology toward the IAEA goals of contributing to peace, health, and prosperity. In order to accomplish advances with AI in general and ML in particular across these fields, IAEA can play a significant role by establishing, hosting and curating centralised resources, including databases, adhering to FAIR (findable, accessible, interoperable and reusable) principles and Open Science best practices, providing stewardship of data sharing, supporting training efforts and development of relevant workforces, as well as enabling connections among the scientific, technology, mathematics, AI and ethics communities. Many areas can benefit from the use of AI in the realm of nuclear applications. In human health, these areas include clinical research, epidemiology, nutrition, medical imaging, radiotherapy and education of health professionals. AI-based tools are also being used to facilitate different clinical tasks in imaging, computer-assisted diagnosis in mammography and lung cancer screening programmes, and dose prediction in nuclear medicine procedures. ML methods in particular may also increase the efficiency and accuracy of the analysis of computerised tomography and dual-energy absorptiometry scans for body composition and bone analysis. The application of AI methods to nuclear and related technologies in food and agriculture can lead to significant advances and improved efficiency in the optimisation of agricultural production, food product development, management of supply chains, food safety and food authenticity control. In the water and environmental sector, AI can help inform policies to mitigate the world’s water problems. The application of AI techniques to hydrology and environmental sciences is expected to improve patterns identification and enable model predictions under a changing climate.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization and Integrated Fabrication of Al Components with Thick TiC{sub p}/Al Composite Coatings via Self-Propagating Reaction

A novel and quick process combining self-propagating reaction with vacuum-expendable pattern casting is presented to accomplish integrated preparation of millimeter-thick TiC{sub p}/Al composite coatings on the Al substrate. Titanium and graphite powders were mixed with the polytetrafluoroethylene (PTFE) additive and pasted on the expendable polystyrene (EPS) followed by compaction. Al components with in situ TiC{sub p}/Al composite coating were simultaneously synthesized at a relatively low temperature of molten Al, which was poured into the assembly of EPS and powder compact inside the silica sands. Differential scanning calorimetry, x-ray diffraction, scanning electron microscopy with energy-dispersive spectroscopy and transmission electron microscopy were used to systematically investigate the thermodynamic characteristics of the reaction, the phase constituents, microstructure and tribological properties of the coatings. The infiltration model describing the densification of the reaction coatings was also developed for the critical wetting condition. The wear characteristics were assessed using a pin-on-disk tribometer with various loads. Results showed that uniform TiC particles stimulated by the PTFE-activated self-propagating reaction afforded superior mechanical properties and wear resistance.

36 MATERIALS SCIENCE↗

Four-Dimensional Dose Reconstruction for Scanned Proton Therapy Using Liver 4DCT-MRI

Purpose: Four-dimensional computed tomography-magnetic resonance imaging (4DCT-MRI) is an image-processing technique for simulating many 4DCT data sets from a static reference CT and motions extracted from 4DMRI studies performed using either volunteers or patients. In this work, different motion extraction approaches were tested using 6 liver cases, and a detailed comparison between 4DCT-MRI and 4DCT was performed. Methods and Materials: 4DCT-MRI has been generated using 2 approaches. The first approach used motion extracted from 4DMRI as being “most similar” to that of 4DCT from the same patient (subject-specific), and the second approach used the most similar motion obtained from a motion library derived from 4DMRI liver studies of 13 healthy volunteers (population-based). The resulting 4DCT-MRI and 4DCTs were compared using scanned proton 4D dose calculations (4DDC). Results: Dosimetric analysis showed that 93% ± 8% of points inside the clinical target volume (CTV) agreed between 4DCT and subject-specific 4DCT-MRI (gamma analysis: 3%/3 mm). The population-based approach however showed lower dosimetric agreement with only 79% ± 14% points in the CTV reaching the 3%/3 mm criteria. Conclusions: 4D CT-MRI extends the capabilities of motion modeling for dose calculations by accounting for realistic and variable motion patterns, which can be directly employed in clinical research studies. We have found that the subject-specific liver modeling appears more accurate than the population-based approach. The former is particularly interesting for clinical applications, such as improved target delineation and 4D dose reconstruction for patient-specific QA to allow for inter- and/or intra-fractional plan corrections.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Crystal structure and dielectric properties of xCa(Mg{sub 1/3}Nb{sub 2/3})O{sub 3}–(1 − x)(Ca{sub 0.61}Nd{sub 0.26})TiO{sub 3} at the microwave frequency

Highlights: • The 0.6Ca(Mg{sub 1/3}Nb{sub 2/3})O{sub 3}–0.4Ca{sub 0.61}Nd{sub 0.26}TiO{sub 3} system is thus proposed for use in microwave devices. • The XRD patterns indicate that the xCMN–(1 − x)CNT ceramic system had a complex perovskite structure. • The τ{sub f} value could be adjusted to near zero. - Abstract: The microwave dielectric properties of the xCa(Mg{sub 1/3}Nb{sub 2/3})O{sub 3}–(1 − x)Ca{sub 0.61}Nd{sub 0.26}TiO{sub 3} ceramic system (x = 0.2, 0.4, 0.6, and 0.8) were investigated. The crystal structures and the microstructures of the ceramics were characterized using X-ray diffraction and scanning electron microscopy analyses, respectively. A near-zero temperature coefficient of resonant frequency was achieved by adjusting the x value of the system. When the x value was increased from 0.2 to 0.8, the dielectric constant ϵ{sub r} decreased from 83 to 34, the quality factor value (Q × f) increased from 13,000 to 45,000 GHz, and the temperature coefficient of resonant frequency (τ{sub r}) decreased from 85 to −21 ppm/°C. The 0.6Ca(Mg{sub 1/3}Nb{sub 2/3})O{sub 3}–0.4Ca{sub 0.61}Nd{sub 0.26}TiO{sub 3} ceramic system is suitable for microwave dielectric resonator applications, as it has an ϵ{sub r} value of ∼47, a Q × f value of ∼37,000 GHz, and a τ{sub r} value of ∼5 ppm/°C.

36 MATERIALS SCIENCE↗

Nanofabrication of silicon surfaces for reduced virus adhesion

Nanofabrication is a remarkably effective technique to create desirable nanoscale patterns. Here, the effect of surface nanofabrication on altering virus adhesion to the substrates was examined. Arrays of nanoholes, 50 nm in diameter, 22 nm deep, and 100 nm in pitch distance, were created on silicon (Si) wafers by electron-beam lithography and reactive ion etching. MS2 coliphage, which is 26 ± 2 nm in diameter and is frequently used as a surrogate for human viruses, was applied to investigate the interaction between the virions and smooth or nanostructured Si surfaces. Scanning electron microscopy and atomic force microscopy along with surface wettability analyses revealed that the nanofabrication had the effect of reducing not only the number of viruses attached but also the strength of virus adhesion. These effects were ascribed to the presence of nanoholes, which were inaccessible to the virions due to the unique surface topographical parameters and the surface chemistry, resulting in the decrease of the overall solid contact area for MS2 attachment. The periodic spacing of the nanoholes also limited the unit landing area for MS2 particles, restricting the formation of MS2 aggregates and leading to the reduced amount of MS2 attachment. We anticipate that smart design of a surface’s chemical composition and nanostructure will offer a feasible solution to improve mitigations for controlling viral adhesion and transmission to and from food contact surfaces.

36 MATERIALS SCIENCE↗

SU-C-9A-06: The Impact of CT Image Used for Attenuation Correction in 4D-PET

Purpose: To evaluate the appropriateness of using 3D non-gated CT image for attenuation correction (AC) in a 4D-PET (gated PET) imaging protocol used in radiotherapy treatment planning simulation. Methods: The 4D-PET imaging protocol in a Siemens PET/CT simulator (Biograph mCT, Siemens Medical Solutions, Hoffman Estates, IL) was evaluated. CIRS Dynamic Thorax Phantom (CIRS Inc., Norfolk, VA) with a moving glass sphere (8 mL) in the middle of its thorax portion was used in the experiments. The glass was filled with {sup 18}F-FDG and was in a longitudinal motion derived from a real patient breathing pattern. Varian RPM system (Varian Medical Systems, Palo Alto, CA) was used for respiratory gating. Both phase-gating and amplitude-gating methods were tested. The clinical imaging protocol was modified to use three different CT images for AC in 4D-PET reconstruction: first is to use a single-phase CT image to mimic actual clinical protocol (single-CT-PET); second is to use the average intensity projection CT (AveIP-CT) derived from 4D-CT scanning (AveIP-CT-PET); third is to use 4D-CT image to do the phase-matched AC (phase-matching- PET). Maximum SUV (SUVmax) and volume of the moving target (glass sphere) with threshold of 40% SUVmax were calculated for comparison between 4D-PET images derived with different AC methods. Results: The SUVmax varied 7.3%±6.9% over the breathing cycle in single-CT-PET, compared to 2.5%±2.8% in AveIP-CT-PET and 1.3%±1.2% in phasematching PET. The SUVmax in single-CT-PET differed by up to 15% from those in phase-matching-PET. The target volumes measured from single- CT-PET images also presented variations up to 10% among different phases of 4D PET in both phase-gating and amplitude-gating experiments. Conclusion: Attenuation correction using non-gated CT in 4D-PET imaging is not optimal process for quantitative analysis. Clinical 4D-PET imaging protocols should consider phase-matched 4D-CT image if available to achieve better accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Charge ordering, ferroelectric, and magnetic domains in LuFe{sub 2}O{sub 4} observed by scanning probe microscopy

LuFe{sub 2}O{sub 4} is a multiferroic system which exhibits charge order, ferroelectricity, and ferrimagnetism simultaneously below ∼230 K. The ferroelectric/charge order domains of LuFe{sub 2}O{sub 4} are imaged with both piezoresponse force microscopy (PFM) and electrostatic force microscopy (EFM), while the magnetic domains are characterized by magnetic force microscopy (MFM). Comparison of PFM and EFM results suggests that the proposed ferroelectricity in LuFe{sub 2}O{sub 4} is not of usual displacive type but of electronic origin. Simultaneous characterization of ferroelectric/charge order and magnetic domains by EFM and MFM, respectively, on the same surface of LuFe{sub 2}O{sub 4} reveals that both domains have irregular patterns of similar shape, but the length scales are quite different. The domain size is approximately 100 nm for the ferroelectric domains, while the magnetic domain size is much larger and gets as large as 1 μm. We also demonstrate that the origin of the formation of irregular domains in LuFe{sub 2}O{sub 4} is not extrinsic but intrinsic.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Detection of nanoscale embedded layers using laboratory specular X-ray diffraction

Unusual specular X-ray diffraction patterns have been observed from certain thin film intergrowths of metal monochalcogenide (MX) and transition metal dichalcogenide (TX{sub 2}) structures. These patterns exhibit selective “splitting” or broadening of selected (00l) diffraction peaks, while other (00l) reflections remain relatively unaffected [Atkins et al., Chem. Mater. 24, 4594 (2012)]. Using a simplified optical model in the kinematic approximation, we illustrate that these peculiar and somewhat counterintuitive diffraction features can be understood in terms of additional layers of one of the intergrowth components, MX or TX{sub 2}, interleaved between otherwise “ideal” regions of MX-TX{sub 2} intergrowth. The interpretation is in agreement with scanning transmission electron microscope imaging, which reveals the presence of such stacking “defects” in films prepared from non-ideal precursors. In principle, the effect can be employed as a simple, non-destructive laboratory probe to detect and characterize ultrathin layers of one material, e.g., 2-dimensional crystals, embedded between two slabs of a second material, effectively using the two slabs as a highly sensitive interferometer of their separation distance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-G-TeP4-03: A Multileaf Collimator Calibration and Quality Assurance Technique Using An Electronic Portal Imaging Device

Purpose: To develop an accurate and quick multileaf collimator (MLC) calibration and quality assurance technique using an electronic portal imaging device (EPID) Methods: The MLC models used include the MLCi and Agility (Elekta Ltd). This technique consists of two 22(L)x10(W) cm{sup 2} fields with 0{sup 0} and 180{sup 0} collimator angles centered to an offset EPID. The MLC opening is estimated by calculating the profile at the image’s center in the image’s horizontal direction. Scans in the image’s vertical direction were calculated every 20 pixels in the inner 70% of estimated MLC opening. The profiles’ edges were fitted with linear equations to determine the image’s rotation angle. Then, crossline profiles were scanned at the center of each leaf taking into account the leaf’s width at isocenter and the rotation angle. The profiles’ edges determine the location of the leaves’ edges and these were subtracted from the reference leaf’s position in order to determine the relative leaf offsets. The edge location of all profiles was determined by using the parameterized gradient of the penumbra region. The technique was tested against an established diode array-based method, and for different MLC systems, patterns, gantry angles, days, energies, beam modalities and MLC openings. Results: The differences between the proposed and established methods were 0.26±0.19mm. The leaf offsets’ deviation was <0.3mm (5 months period). For pattern fields, the differences between predetermined and calculated offsets were 0.18±0.18mm. The leaf offset deviation of measurements with different energies and MLC openings were <0.1mm and <0.3mm, respectively. The differences between offsets of FF and FFF beams were 0.01±0.02mm (<0.07mm). The differences between the offsets at different gantry angles were 0.08±0.15mm. Conclusion: The proposed method proved to be accurate and efficient in calculating the relative leaf offsets. Parameterized field edge is essential to obtain accurate result by eliminating the noise from EPID.

60 APPLIED LIFE SCIENCES↗

Soft X-ray reflection ptychography

Scanning transmission X-ray microscopy and ptychography have become mature tools for high-resolution, element-specific imaging of nanoscale structures. However, transmission geometries impose stringent constraints on sample thickness and preparation, thereby limiting investigations of extended or bulk specimens, especially in the soft X-ray region. Here, we demonstrate reflection-geometry soft X-ray ptychography as a robust imaging mode. Instrumental feasibility and spatial resolution are established using a lithographically defined Siemens star and barcode test pattern on a multilayer substrate. We empirically demonstrate a full-pitch spatial resolution of ca. 45 nm from Fourier ring correlation analysis of the reconstructed object. The results highlight the potential of the reflection geometry for nondestructive X-ray studies of materials without the need for transmissive samples.

Guenzing, Damian [Lawrence Berkeley National Labor↗

Study of ZnO and Mg doped ZnO nanoparticles by sol-gel process

Nano-crystalline undoped and Mg doped ZnO (Mg-ZnO) nanoparticles with compositional formula Mg{sub x}Zn{sub 1-x}O (x=0,1,3,5,7,10 and 12 %) were synthesized using sol-gel process. The XRD diffraction peaks match with the pattern of the standard hexagonal structure of ZnO that reveals the formation of hexagonal wurtzite structure in all samples. SEM images demonstrates clearly the formation of spherical ZnO nanoparticles, and change of the morphology of the nanoparticles with the concentration of the magnesium, which is in close agreement with that estimated by Scherer formula based on the XRD pattern. To investigate the doping effect on optical properties, the UV–VIS absorption spectra was obtained and the band gap of the samples calculated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Efficient modeling of Bragg coherent x-ray nanobeam diffraction

X-ray Bragg diffraction experiments that utilize tightly focused coherent beams produce complicated Bragg diffraction patterns that depend on scattering geometry, characteristics of the sample, and properties of the x-ray focusing optic. In this paper, we use a Fourier-transform-based method of modeling the 2D intensity distribution of a Bragg peak and apply it to the case of thin films illuminated with a Fresnel zone plate in three different Bragg scattering geometries. Finally, the calculations agree well with experimental coherent diffraction patterns, demonstrating that nanodiffraction patterns can be modeled at nonsymmetric Bragg conditions with this approach—a capability critical for advancing nanofocused x-ray diffraction microscopy.

36 MATERIALS SCIENCE↗

Synthesis, Characterization, and Reactivity of Ethynyl- and Propynyl-Terminated Si(111) Surfaces

Ethynyl- and propynyl-terminated Si(111) surfaces synthesized with a two-step halogenation/alkylation method have been characterized by transmission infrared spectroscopy (TIRS), high-resolution electron energy-loss spectroscopy (HREELS), X-ray photoelectron spectroscopy (XPS), low-energy electron diffraction (LEED), atomic-force microscopy (AFM), electrochemical scanning–tunneling microscopy (EC-STM) and measurements of surface recombination velocities ( S ). For the ethynyl-terminated Si(111) surface, TIRS revealed signals corresponding to ethynyl ≡C–H and C≡C stretching oriented perpendicular to the surface, HREELS revealed a Si–C stretching signal, and XPS data showed the presence of C bound to Si with a fractional monolayer (ML) coverage (Φ) of Φ Si–CCH = 0.63 ± 0.08 ML. The ethynyl-terminated surfaces were also partially terminated by Si–OH groups (Φ Si–OH = 0.35 ± 0.03 ML) with limited formation of Si 3+ and Si 4+ oxides. For the propynyl-terminated Si(111) surface, TIRS revealed the presence of a (C–H) CH 3 symmetric bending, or “umbrella,” peak oriented perpendicular to the surface, while HREELS revealed signals corresponding to Si–C and C≡C stretching, and XPS showed C bound to Si with Φ Si–CCCH 3 = 1.05 ± 0.06 ML. The LEED patterns were consistent with a (1 × 1) surface unit cell for both surfaces, but room-temperature EC-STM indicated that the surfaces did not exhibit long-range ordering. HCC–Si(111) and CH 3 CC–Si(111) surfaces yielded S values of (3.5 ± 0.1) × 10 3 and (5 ± 1) × 10 2 cm s –1 , respectively, after 581 h exposure to air. These determinations are consistent with the covalent binding of ethynyl and propynyl groups, respectively, to the Si(111) surface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Prospective Study of Hippocampal-Sparing Prophylactic Cranial Irradiation in Limited-Stage Small Cell Lung Cancer

Purpose: To prospectively evaluate cognitive function and intracranial failure patterns after hippocampal-sparing prophylactic cranial irradiation (PCI) for limited-stage small cell lung cancer (SCLC). Methods and Materials: Adults with limited-stage SCLC, achieving a complete response to chemoradiotherapy and no brain metastases, were eligible. Patients received PCI 25 Gy/10 fractions, with a mean hippocampal dose limited to <8 Gy and ≥90% of the brain receiving 90% of the prescription. A diverse battery of neuropsychological testing was performed at baseline and 6 and 12 months after PCI. Brain MRI scans were performed at baseline and 6, 12, 18, and 24 months. The primary endpoint was memory measured by the Hopkins Verbal Learning Test-Revised Delayed Recall at 6 months after PCI. The 25-Gy arm of Radiation Therapy Oncology Group protocol 0212 was used as a reference of potential efficacy. Development of intracranial metastases was recorded. Overall survival and progression-free survival were estimated using the Kaplan-Meier method. Results: Eight men and 12 women with a median age of 61 years enrolled. Two-year overall survival was 88% (95% confidence interval 68%-100%). There was no significant decline in performance between baseline and 6 or 12 months for any of the tests. The association between baseline intelligence quotient and change in performance on testing was not significant. Magnetic resonance imaging revealed asymptomatic brain metastases at a cumulative rate of 20%, with no concurrent extracranial progression. Two patients developed a metastasis in the under-dosed region. Neither involved the dentate gyrus, but 1 involved the avoidance region. Both patients concurrently developed additional metastasis in fully treated brain regions. There were 2 neurologic deaths. Conclusions: This prospective study suggests a potential benefit of hippocampal sparing in limiting the neuropsychological sequelae of brain radiation, but with a risk of failures in the spared region. These data strongly support continued enrollment on ongoing cooperative group randomized trials. Clinical Trials registration number: (NCT01797159).

62 RADIOLOGY AND NUCLEAR MEDICINE↗