Search NASA⌕ Search

SEARCH · Search NASA

Results for “simulator study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,315 records · Page 73

Physics-based shape matching for intraoperative image guidance

Purpose: Soft-tissue deformations can severely degrade the validity of preoperative planning data during computer assisted interventions. Intraoperative imaging such as stereo endoscopic, time-of-flight or, laser range scanner data can be used to compensate these movements. In this context, the intraoperative surface has to be matched to the preoperative model. The shape matching is especially challenging in the intraoperative setting due to noisy sensor data, only partially visible surfaces, ambiguous shape descriptors, and real-time requirements. Methods: A novel physics-based shape matching (PBSM) approach to register intraoperatively acquired surface meshes to preoperative planning data is proposed. The key idea of the method is to describe the nonrigid registration process as an electrostatic–elastic problem, where an elastic body (preoperative model) that is electrically charged slides into an oppositely charged rigid shape (intraoperative surface). It is shown that the corresponding energy functional can be efficiently solved using the finite element (FE) method. It is also demonstrated how PBSM can be combined with rigid registration schemes for robust nonrigid registration of arbitrarily aligned surfaces. Furthermore, it is shown how the approach can be combined with landmark based methods and outline its application to image guidance in laparoscopic interventions. Results: A profound analysis of the PBSM scheme based on in silico and phantom data is presented. Simulation studies on several liver models show that the approach is robust to the initial rigid registration and to parameter variations. The studies also reveal that the method achieves submillimeter registration accuracy (mean error between 0.32 and 0.46 mm). An unoptimized, single core implementation of the approach achieves near real-time performance (2 TPS, 7–19 s total registration time). It outperforms established methods in terms of speed and accuracy. Furthermore, it is shown that the method is able to accurately match partial surfaces. Finally, a phantom experiment demonstrates how the method can be combined with stereo endoscopic imaging to provide nonrigid registration during laparoscopic interventions. Conclusions: The PBSM approach for surface matching is fast, robust, and accurate. As the technique is based on a preoperative volumetric FE model, it naturally recovers the position of volumetric structures (e.g., tumors and vessels). It cannot only be used to recover soft-tissue deformations from intraoperative surface models but can also be combined with landmark data from volumetric imaging. In addition to applications in laparoscopic surgery, the method might prove useful in other areas that require soft-tissue registration from sparse intraoperative sensor data (e.g., radiation therapy)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the Chlorination Products of Zirconium Alloys used for Nuclear Fuel Cladding

The United States produces over 2000 metric tons of used nuclear fuel material per year, of which 25% is irradiated fuel cladding, and it is expected to increase for the next 50 years. Previous simulation studies have shown that in the irradiated cladding, the major activation products found are {sup 125}Sb, {sup 60}Co, and {sup 99m}Nb, and the major fission product found is {sup 137}Cs. These radioisotopes make it impossible to treat the cladding as low level waste. A chlorination process has been proposed for zirconium reprocessing as it has been proven more efficient than previous mechanical processes, redox processes, and other chemical methods (e.g. iodination). In the chlorination process, zirconium alloy cladding reacts with Cl{sub 2} at 350- 380 deg. C to produce mainly ZrCl{sub 4}. The zirconium tetrachloride has a relatively low sublimation point (331 deg. C) that allows its separation from other products, and so it can be treated as low level waste for disposal or recycling. However, previous work has observed element impurities (iron, tin, chromium, cesium, antimony, and niobium) in the recovered ZrCl{sub 4}, meaning that additional steps are necessary in a chlorination process previous to the reduction of ZrCl, to metallic Zr. The emphasis of this research summary is on the progress that has been made to isolate and characterize the impurities produced after chlorination of three previously characterized non-irradiated zirconium alloys (Zircaloy-2, Zircaloy-4, and a commercial Zr-Nb alloy) widely used as cladding materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Particle simulation of femtosecond laser stimulation of electrical discharges in small gaps

A particle-in-cell/Monte Carlo collision simulation study of femtosecond laser stimulation of electrical discharges in submicron gaps between platinum scanning tunneling microscope cathode tips and gold film anodes in atmospheric pressure argon gas is described. The breakdown potential of gaps containing either preloaded electrons or preloaded neutral and ionized platinum atoms and electrons at various densities were compared to the breakdown potential of gaps with background argon gas alone. It was found that gaps preloaded with sufficient densities of either electrons or partially ionized electrode materials broke down at cathode potential of -80 V while gaps with background argon gas alone required applied cathode potentials between -200 to -250 V to cause a breakdown. Also, partially ionized material was much more effective at stimulating breakdown than electrons alone. The density of preloaded partially ionized platinum required to lower breakdown cathode potential to -80 V was approximately 12.5 times smaller than that required for the preloaded electrons alone in the same size gap. Analysis of the mechanism by which the preloaded partially ionized material promoted breakdown showed that laser ablated ions located near the cathode tip increased the local field at the cathode surface and the field-emitted electron flux from the cathode. This higher electron flux ionized background argon gas and preloaded platinum which resulted in gap breakdown. The threshold density of partially ionized platinum for gap breakdown varied approximately linearly with applied cathode potential.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An iterative method for tomographic x-ray perfusion estimation in a decomposition model-based approach

Purpose: X-ray based tomographic blood perfusion imaging requires recovery of contrast time-attenuation-curves from dynamic projection data. When using slowly rotating imaging systems, this task is challenging due to nonsimultaneous projection acquisition. A dynamic reconstruction method is proposed that aims at compensating the lack of simultaneously acquired information by incorporating prior knowledge about the expected temporal contrast dynamics. Methods: A decomposition model using temporal basis functions to approximate time-attenuation-curves is integrated into an iterative tomographic reconstruction method. The computationally efficient implementation of the proposed approach makes use of standard forward-projections and backprojections, as well as scalar products in image space. The critical issue of projection noise propagation is tackled by the application of regularization which is realized by the early stopping of iteration cycles and by the proper selection of smooth temporal basis functions. The performance of the proposed dynamic reconstruction approach is evaluated in a simulation study concerning various aspects: Noise propagation and regularization, specification of the temporal model, and type of acquisition mode. Results: The evaluation based on dynamic phantom data indicates that tomographic recovery of contrast time-attenuation-curves in tissue can be achieved with an average range of accuracy of {approx}2% (with respect to dynamic peak attenuation) under ideal noise-free conditions. The relative estimation error for arterial time-attenuation-curves is in the range of 8%, which is due to faster contrast dynamics in the artery. In general, performance depends on the level of acquired information contained in the projection data, which is mainly influenced by the type of rotational acquisition mode; restrictions in angular range and speed can lead to limited accuracy. The analysis of propagated projection noise in a statistical bias-variance framework reveals relative noise levels in estimated time-attenuation-curves of 3%-4% in tissue regions and below 1% in vessels when using optimized settings for regularization. Here, the effect of noise suppression depends on the interrelation between the number of iteration cycles and the constraints imposed by the temporal decomposition model. Conclusions: For usage with slowly rotating imaging systems, the presented model-based iterative dynamic reconstruction method is capable of recovering contrast time-attenuation-curves related to tissue perfusion. The proposed regularization framework is an effective means to limit the impact of projection noise, which is a factor dominating estimation accuracy in tissue regions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phantom study to evaluate contrast-medium-enhanced digital subtraction mammography with a full-field indirect-detection system

This phantom study simulates contrast-medium-enhanced digital subtraction mammography (CEDM) and compares subtracted image quality and total mean glandular dose for two alternative spectral combinations available in a GE Senographe DS mammography unit. The first choice takes advantage of large iodine attenuation at low photon energies and uses traditionally available spectra (anode/filter combinations Mo/Mo at 25 kV and Rh/Rh at 40 kV, ''Mo25-Rh40''). The second choice, selected from a previous analytical optimization, includes harder spectra obtained by adding external filtration to traditional beams (Rh/Rh at 34 kV and Rh/Rh+5 mm of Al at 45 kV, ''Rh34-Rh45H''). Individual images of a custom-made phantom containing tubes of various diameters filled with water- or iodine-based contrast agent were acquired with both spectral combinations. The total breast entrance air kerma, considering subtraction of two images, was limited to 8.76 mGy (1 R). The results were compared to predictions obtained through an analytical formalism that assumes noise of stochastic origin. Individual images were evaluated and subtracted under five combinations of temporal and dual-energy modalities. Signal variance analysis in individual raw images showed important contributions of nonstochastic origin, associated with the software applied to raw images, the curved geometry, and strong attenuation of the phantom cylindrical iodine-filled tubes, causing experimental SNR to vary from 2.2 to 0.8 times the predictions from low to high values of SNR. Iodine contrast in the subtracted images was found to be mainly defined by the spectra, independent of exposure, and linearly dependent on the iodine mass thickness. The highest contrast was obtained with the combined dual-energy temporal subtraction with Rh34-Rh45H, its value was 7% larger than the highest value measured with Mo25-Rh40. As expected, temporal modalities (single and dual energy, any spectral choice) led to higher contrast-over-noise ratio (CNR) than nontemporal dual-energy subtraction, the latter being negligibly small with Mo25-Rh40. CNR for 4 mg iodine/cm{sup 2} imaged temporally in a dual-energy fashion with Rh34-Rh45H (iodine imaged at high energy) is about 1.7 times the optimum for Mo25-Rh40 (iodine imaged at low energy). Iodine thicknesses needed to fulfill Rose's criterion were 0.78{+-}0.02 mg iodine/cm{sup 2} for Mo25-Rh40 and 0.54{+-}0.17 mg iodine/cm{sup 2} for Rh34-Rh45H, both lower than the proposed biological concentration of iodine in breast tumors after contrast medium administration. Although similar dose levels were obtained with both spectral choices under dual-energy (temporal and nontemporal) subtraction, the dose obtained in single-energy temporal subtraction with the Mo25 spectrum was 1.2 mGy lower than the dose from the modality offering the highest CNR. In all results considered, the spectral choice Mo25-Rh40 was found to represent an interesting alternative to the use of high-energy hardened spectra for CEDM, particularly when performing dynamic studies of the contrast-agent uptake in breast lesions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Ultra-Short Electron Bunch and X-Ray Temporal Diagnostics with an X-Band Transverse Deflector

The measurement of ultra-short electron bunches on the femtosecond time scale constitutes a very challenging problem. In X-ray free-electron laser facilities such as the Linac Coherent Light Source (LCLS), generation of sub-ten femtosecond X-ray pulses is possible, and some efforts have been put into both ultra-short electron and X-ray beam diagnostics. Here we propose a single-shot method using a transverse rf deflector (X-band) after the undulator to reconstruct both the electron bunch and X-ray temporal profiles. Simulation studies show that about 1 fs (rms) time resolution may be achievable in the LCLS and is applicable to a wide range of FEL wavelengths and pulse lengths. The jitter, resolution and other related issues will be discussed. The successful operation of the Linac Coherent Light Source (LCLS), with its capability of generating free-electron laser (FEL) X-ray pulses from a few femtoseconds (fs) up to a few hundred fs, opens up vast opportunities for studying atoms and molecules on this unprecedented ultrashort time scale. However, tremendous challenges remain in the measurement and control of these ultrashort pulses with femtosecond precision, for both the electron beam (e-beam) and the X-ray pulses. For ultrashort e-beam bunch length measurements, a standard method has been established at LCLS using an S-band radio-frequency (rf) deflector, which works like a streak camera for electrons and is capable of resolving bunch lengths as short as {approx} 10 fs rms. However, the e-beam with low charges of 20 pC at LCLS, which is expected to be less than 10 fs in duration, is too short to be measured using this transverse deflector. The measurement of the electron bunch length is helpful in estimating the FEL X-ray pulse duration. However, for a realistic beam, such as that with a Gaussian shape or even a spiky profile, the FEL amplification varies along the bunch due to peak current or emittance variation. This will cause differences between the temporal shape or duration of the electron bunch and the X-ray pulse. Initial experiments at LCLS have revealed that characterization of the X-ray pulse duration on a shot-by-shot basis is critical for the interpretation of the data. However, a reliable x-ray pulse temporal diagnostic tool is not available so far at the LCLS. We propose a novel method in this paper to characterize the FEL X-ray pulse duration and shape. A transverse rf deflector is used in conjunction with an e-beam energy spectrometer, located after the FEL undulator. By measuring the difference in the e-beam longitudinal phase space between FEL-on and FEL-off, we can obtain the time-resolved energy loss and energy spread induced from the FEL radiation, allowing the FEL X-ray temporal shape to be reconstructed.

43 PARTICLE ACCELERATORS↗

National Security Science and Technology Initiative: Air Cargo Screening

The non-intrusive inspection (NII) of consolidated air cargo carried on commercial passenger aircraft continues to be a technically challenging, high-priority requirement of the Department of Homeland Security's Science and Technology Directorate (DHS S&T), the Transportation Security Agency and the Federal Aviation Administration. The goal of deploying a screening system that can reliably and cost-effectively detect explosive threats in consolidated cargo without adversely affecting the flow of commerce will require significant technical advances that will take years to develop. To address this critical National Security need, the Battelle Memorial Institute (Battelle), under a Cooperative Research and Development Agreement (CRADA) with four of its associated US Department of Energy (DOE) National Laboratories (Oak Ridge, Pacific Northwest, Idaho, and Brookhaven), conducted a research and development initiative focused on identifying, evaluating, and integrating technologies for screening consolidated air cargo for the presence of explosive threats. Battelle invested $8.5M of internal research and development funds during fiscal years 2007 through 2009. The primary results of this effort are described in this document and can be summarized as follows: (1) Completed a gap analysis that identified threat signatures and observables, candidate technologies for detection, their current state of development, and provided recommendations for improvements to meet air cargo screening requirements. (2) Defined a Commodity/Threat/Detection matrix that focuses modeling and experimental efforts, identifies technology gaps and game-changing opportunities, and provides a means of summarizing current and emerging capabilities. (3) Defined key properties (e.g., elemental composition, average density, effective atomic weight) for basic commodity and explosive benchmarks, developed virtual models of the physical distributions (pallets) of three commodity types and three explosive benchmarks combinations, and conducted modeling and simulation studies to begin populating the matrix of commodities, threats, and detection technologies. (4) Designed and fabricated basic (homogeneous) commodity test pallets and fabricated inert stimulants to support experiments and to validate modeling/simulation results. (5) Developed/expanded the team's capabilities to conduct full-scale imaging (neutron and x-ray) experiments of air cargo commodities and explosive benchmarks. (6) Conducted experiments to improve the collection of trace particles of explosives from a variety of surfaces representative of air cargo materials by means of mechanical (air/vibration/pressure), thermal, and electrostatic methods. Air cargo screening is a difficult challenge that will require significant investment in both research and development to find a suitable solution to ensure the safety of passengers without significantly hindering the flow of commodities. The initiative funded by Battelle has positioned this group to make major contributions in meeting the air cargo challenge by developing collaborations, developing laboratory test systems, improving knowledge of the challenges (both technical and business) for air cargo screening, and increasing the understanding of the capabilities for current inspection methods (x-ray radiography, x-ray backscatter, etc.) and potential future inspection methods (neutron radiography, fusion of detector modalities, advanced trace detection, etc.). Lastly, air cargo screening is still an issue that will benefit from collaboration between Department of Energy Laboratories and Battelle. On January 7, 2010, DHS Secretary Napolitano joined White House Press Secretary Robert Gibbs and Assistant to the President for Counterterrorism and Homeland Security John Brennan to announce several recommendations DHS has made to the President for improving the technology and procedures used to protect air travel from acts of terrorism. (This announcement followed the 25 Dec'09 Delta/Northwest Airlines Flight 253 terror attack.) Secretary Napolitano outlined five recommendations DHS will pursue to enhance the safety of the traveling public. One of the five recommendations, read as follows: 'Establish a partnership on aviation security between DHS and the Department of Energy and its National Laboratories in order to develop new and more effective technologies to deter and disrupt known threats and proactively anticipate and protect against new ways by which terrorists could seek to board an aircraft.' In conclusion, it appears very timely that Battelle and its DOE lab partners initiated a serious collaboration on the air cargo topic, and that we should continue to work toward future collaboration in response to the government's needs.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Extremum seeking for optimal control problems with unknown time-varying systems and unknown objective functions

We consider the problem of optimal feedback control of an unknown, noisy, time-varying, dynamic system that is initialized repeatedly. Examples include a robotic manipulator which must perform the same motion, such as assisting a human, repeatedly and accelerating cavities in particle accelerators which are turned on for a fraction of a second with given initial conditions and vary slowly due to temperature fluctuations. In this paper, we present an approach that applies to systems of practical interest. The method presented here is model independent; does not require knowledge of the objective function; is robust to measurement noise; is applicable for any set of initial conditions; is applicable to simultaneously controlling an arbitrary number of parameters; and may be implemented with a broad range of continuous or discontinuous functions such as sine or square waves. For systems with convex cost functions we prove that our algorithm will produce controllers that approach the minimal cost. For linear systems we reproduce the cost minimizing linear quadratic regulator optimal controller that could have been designed analytically had the system and cost function been known. We demonstrate the effectiveness of the algorithm with simulation studies of noisy and time-varying systems.

42 ENGINEERING↗

Epitaxially Self-Assembled Alkane Layers for Graphene Electronics

The epitaxially grown alkane layers on graphene are prepared by a simple drop-casting method and greatly reduce the environmentally driven doping and charge impurities in graphene. Here, multiscale simulation studies exhibit that this enhancement of charge homogeneity in graphene originates from the lifting of graphene from the SiO 2 surface toward the well-ordered and rigid alkane self-assembled layers.

36 MATERIALS SCIENCE↗

Ultrafine Pt Nanoparticle-Decorated Pyrite-Type CoS 2 Nanosheet Arrays Coated on Carbon Cloth as a Bifunctional Electrode for Overall Water Splitting

To improve the utilization efficiency of precious metals, metal-supported materials provide a direction for fabricating highly active and stable heterogeneous catalysts. Here, carbon cloth (CC)-supported Earth-abundant CoS 2 nanosheet arrays (CoS 2 /CC) are presented as ideal substrates for ultrafine Pt deposition (Pt-CoS 2 /CC) to achieve remarkable performance toward the hydrogen and oxygen evolution reactions (HER/OER) in alkaline solutions. Notably, the Pt-CoS 2 /CC hybrid delivers an overpotential of 24 mV at 10 mA cm –2 and a mass activity of 3.89 A Ptmg –1 , which is 4.7 times higher than that of commercial Pt/C, at an overpotential of 130 mV for catalyzing the HER. An alkali-electrolyzer using Pt-CoS 2 /CC as a bifunctional electrode enables a water-splitting current density of 10 mA cm –2 at a low voltage of 1.55 V and can sustain for more than 20 h, which is superior to that of the state-of-the-art Pt/C+RuO 2 catalyst. Further experimental and theoretical simulation studies demonstrate that strong electronic interaction between Pt and CoS 2 synergistically optimize hydrogen adsorption/desorption behaviors and facilitate the in situ generation of OER active species, enhancing the overall water-splitting performance. This research highlights the regulation of interfacial and electronic synergy in pursuit of highly efficient and durable supported catalysts for hydrogen and oxygen electrocatalytic applications.

36 MATERIALS SCIENCE↗

Ensemble survival trees for identifying subpopulations in personalized medicine

Recently, personalized medicine has received great attention to improve safety and effectiveness in drug development. Personalized medicine aims to provide medical treatment that is tailored to the patient's characteristics such as genomic biomarkers, disease history, etc., so that the benefit of treatment can be optimized. Subpopulations identification is to divide patients into several different subgroups where each subgroup corresponds to an optimal treatment. For two subgroups, traditionally the multivariate Cox proportional hazards model is fitted and used to calculate the risk score when outcome is survival time endpoint. Median is commonly chosen as the cutoff value to separate patients. However, using median as the cutoff value is quite subjective and sometimes may be inappropriate in situations where data are imbalanced. Here, we propose a novel tree‐based method that adopts the algorithm of relative risk trees to identify subgroup patients. After growing a relative risk tree, we apply k‐means clustering to group the terminal nodes based on the averaged covariates. We adopt an ensemble Bagging method to improve the performance of a single tree since it is well known that the performance of a single tree is quite unstable. A simulation study is conducted to compare the performance between our proposed method and the multivariate Cox model. The applications of our proposed method to two public cancer data sets are also conducted for illustration.

Chen, Yu‐Chuan↗

Estimation of conditional cumulative incidence functions under generalized semiparametric regression models with missing covariates, with application to analysis of biomarker correlates in vaccine trials

Herein, this article presents generalized semiparametric regression models for conditional cumulative incidence functions with competing risks data when covariates are missing by sampling design or happenstance. A doubly robust augmented inverse probability weighted (AIPW) complete-case approach to estimation and inference is investigated. This approach modifies IPW complete-case estimating equations by exploiting the key features in the relationship between the missing covariates and the phase-one data to improve efficiency. An iterative numerical procedure is derived to solve the nonlinear estimating equations. The asymptotic properties of the proposed estimators are established. A simulation study examining the finite-sample performances of the proposed estimators shows that the AIPW estimators are more efficient than the IPW estimators. The developed method is applied to the RV144 HIV-1 vaccine efficacy trial to investigate vaccine-induced IgG binding antibodies to HIV-1 as correlates of acquisition of HIV-1 infection while taking account of whether the HIV-1 sequences are near or far from the HIV-1 sequences represented in the vaccine construct.

97 MATHEMATICS AND COMPUTING↗

Understanding the Unusual Adsorption Behavior in Hierarchical Zeolite Nanosheets

Hierarchical zeolites are advanced materials possessing the catalytic and adsorption properties of conventional zeolites while eliminating their transport limitations through the introduction of mesopores. Recent experiments comparing the adsorption in hierarchical self-pillared pentasils (SPP) and silicalite-1 (MFI) revealed an interesting crossover in sorbate loading for branched or long-chain alkanes but not for shorter linear alkanes, but an explanation for this behavior is not readily available through experimental probes due to the complications arising from the presence of multiple adsorption sites. We present a molecular simulation study on the adsorption of alkane isomers and show that a multi-step mechanism, found here for all molecules, is responsible for the observed phenomena.

36 MATERIALS SCIENCE↗

Joint Modeling of Wind Speed and Wind Direction Through a Conditional Approach

Atmospheric near surface wind speed and wind direction play an important role in many applications, ranging from air quality modeling, building design, wind turbine placement to climate change research. It is therefore crucial to accurately estimate the joint probability distribution of wind speed and direction. In this work, we develop a conditional approach to model these two variables, where the joint distribution is decomposed into the product of the marginal distribution of wind direction and the conditional distribution of wind speed given wind direction. To accommodate the circular nature of wind direction, a von Mises mixture model is used; the conditional wind speed distribution is modeled as a directional dependent Weibull distribution via a two-stage estimation procedure, consisting of a directional binned Weibull parameter estimation, followed by a harmonic regression to estimate the dependence of the Weibull parameters on wind direction. A Monte Carlo simulation study indicates that our method outperforms two other approaches in estimation efficiency: one that utilizes periodic spline quantile regression and another that generates data from the commonly used Abe-Ley distribution for cylindrical data. We illustrate our method by using the output from a regional climate model to investigate how the joint distribution of wind speed and direction may change under some future climate scenarios. Our method indicates significant changes in the variation of wind speed with respect to some directions.

17 WIND ENERGY↗

Modeling biomass gasification system using multistep kinetics under various oxygen–steam conditions

Biomass gasification is an effective method to convert low‐value lingocellulosic biomass into useful gas products. The ability to predict the gas composition is important to process design. In this study, simulations of biomass gasification were carried out for various feedstocks at different operating conditions, and the model results were validated using experimental data. A multistep kinetics model was developed to predict the syngas composition using different biomass feedstocks under various oxygen‐enriched air and steam conditions. The oxygen level in the gasifying agent ranged from 21% (air) to 45% (pure oxygen). Five different biomass materials were used, including pine, maple–oak mixture, seed corn, corn stover, and switchgrass. The fluidized bed gasifier was maintained at 800°C. The present kinetics model was able to predict the concentrations of H 2 , CO, CO 2 , H 2 O, CH 4 , and N 2 in the syngas, and the predicted compositions were in good agreement with the experimental data. The results show that the model was sensitive to the variation in the oxygen level, steam flow rate, and the composition of the biomass material. As the oxygen level increased, the model also predicted the increase in H 2 , CO, CH 4 , and the H 2 /CO ratio. The mechanism on improving the syngas quality was also explained by analyzing the reaction equations. The increase in hydrogen is believed to be due to the use of steam for gasification. The present model can further be integrated into the process simulation model for predicting the performance of a biorefinery to help utilize biomass energy. © 2015 American Institute of Chemical Engineers Environ Prog, 34: 1148–1155, 2015

Banerjee, Sudhanya↗

Modeling interval trendlines: Symbolic singular spectrum analysis for interval time series

Abstract In this article we propose an extension of singular spectrum analysis for interval‐valued time series. The proposed methods can be used to decompose and forecast the dynamics governing a set‐valued stochastic process. The resulting components on which the interval time series is decomposed can be understood as interval trendlines, cycles, or noise. Forecasting can be conducted through a linear recurrent method, and we devised generalizations of the decomposition method for the multivariate setting. The performance of the proposed methods is showcased in a simulation study. We apply the proposed methods so to track the dynamics governing the Argentina Stock Market (MERVAL) in real time, in a case study over a period of turbulence that led to discussions of the government of Argentina with the International Monetary Fund.

de Carvalho, Miguel↗

Failure time distributions for complex equipment

The exponential distribution is inadequate as a failure time model for most components; however, under certain conditions (in particular, that component failure rates are small and mutually independent, and failed components are immediately replaced or perfectly repaired), it is applicable to complex repairable systems with large numbers of components in series, regardless of component distributions, as shown by Drenick in 1960. This result implies that system behavior may become simpler as more components are added. We review necessary conditions for the result and present some simulation studies to assess how well it holds in systems with finite numbers of components. Lastly, we also note that Drenick's result is analogous to similar results in other systems disciplines, again resulting in simpler behavior as the number of entities in the system increases.

42 ENGINEERING↗

Monitoring covariance in multivariate time series: Comparing machine learning and statistical approaches

Abstract In complex systems with multiple variables monitored at high‐frequency, variables are not only temporally autocorrelated, but they may also be nonlinearly related or exhibit nonstationarity as the inputs or operation changes. One approach to handling such variables is to detrend them prior to monitoring and then apply control charts that assume independence and stationarity to the residuals. Monitoring controlled systems is even more challenging because the control strategy seeks to maintain variables at prespecified mean levels, and to compensate, correlations among variables may change, making monitoring the covariance essential. In this paper, a vector autoregressive model (VAR) is compared with a multivariate random forest (MRF) and a neural network (NN) for detrending multivariate time series prior to monitoring the covariance of the residuals using a multivariate exponentially weighted moving average (MEWMA) control chart. Machine learning models have an advantage when the data's structure is unknown or may change. We design a novel simulation study with nonlinear, nonstationary, and autocorrelated data to compare the different detrending models and subsequent covariance monitoring. The machine learning models have superior performance for nonlinear and strongly autocorrelated data and similar performance for linear data. An illustration with data from a reverse osmosis process is given.

Weix, Derek↗