Search NASA⌕ Search

SEARCH · Search NASA

Results for “RECOMMENDATIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,333 records · Page 74

Evaluating Knowledge to Support Climate Action: A Framework for Sustained Assessment. Report of an Independent Advisory Committee on Applied Climate Assessment

As states, cities, tribes, and private interests cope with climate damages and seek to increase preparedness and resilience, they will need to navigate myriad choices and options available to them. Making these choices in ways that identify pathways for climate action that support their development objectives will require constructive public dialogue, community participation, and flexible and ongoing access to science- and experience-based knowledge. In 2016, a Federal Advisory Committee (FAC) was convened to recommend how to conduct a sustained National Climate Assessment (NCA) to increase the relevance and usability of assessments for informing action. The FAC was disbanded in 2017, but members and additional experts reconvened to complete the report that is presented here. A key recommendation is establishing a new nonfederal ‘‘climate assessment consortium’’ to increase the role of state/local/tribal government and civil society in assessments. The expanded process would 1) focus on applied problems faced by practitioners, 2) organize sustained partnerships for collaborative learning across similar projects and case studies to identify effective tested practices, and 3) assess and improve knowledge-based methods for project implementation. Specific recommendations include evaluating climate models and data using user-defined metrics; improving benefit–cost assessment and supporting decision-making under uncertainty; and accelerating application of tools and methods such as citizen science, artificial intelligence, indicators, and geospatial analysis. The recommendations are the result of broad consultation and present an ambitious agenda for federal agencies, state/local/tribal jurisdictions, universities and the research sector, professional associations, nongovernmental and community-based organizations, and private-sector firms.

54 ENVIRONMENTAL SCIENCES↗

Abiotic Degradation Rates for Carbon Tetrachloride: and Chloroform: Progress in FY 2008

This is a letter report summarizing work performed in FY2008 to determine the rates of carbon tetrachloride hydrolysis at temperatures close to actual groundwater temperatures. The report describes the project, the methodology, and the results obtained since the project's inception in FY2006. Measurements of hydrolysis rates in homogeneous solution have been completed for temperaturs of 70 C through 40 C, with additional data available at 30 C and 20 C. These results show no difference between the rates in deionized H2O and in filter-sterilized Hanford-Site groundwater. Moreover, the rates measured are 2-3 times slower than predicted from the open literature. Measurements of rates involving sterile suspensions of Hanford-Site sediment in Hanford-Site groundwater, however, show faster hydrolysis at temperatures below 40 C. Extrapolation of the current data available suggests a six-fold increase in rate would be expected at groundwater temperature of 16 C due to the presence of the sediment. This result translates into a 78-year half-life, rather than the 470-680 year half-life that would be predicted from rate determinations in homogeneous solution. The hydrolysis rate data at 20 C, in contrast to those at higher temperatures, are preliminary and have low statistical power. While significant (p < 0.05) differences between the heterogeneous and homogeneous systems are seen at 30 C, the results at 20 C are not statistically significant at this level due to limited data and the very slow nature of the reaction. More time is needed to collect data at these low temperatures to improve the statistical power of our observation. Given the critical need for hydrolysis rate data at temperatures relevant to groundwater systems, we have three recommendations for future work. First, we recommend a continuation of the sampling and analysis of the remaining long-term sealed-ampule experiments described in this report. These are primarily 20 C and 30 C experiments. The data at 20°C, which are most germane to the groundwater environment, will likely take two more years before they are complete. Second, due to the importance of heterogeneous effects, we recommend the continuation of sampling and analysis for a similar set of experiments looking at hydrolysis rates of CT and CF in contact with individual minerals (montmorillonite, kaolinite, albite, and muscovite) or Hanford-Site sediment, and, for CF, in homogeneous solutions. These experiments were set up under a separate project funded by a congressional earmark (EM-22) for which funding expired at the end of FY08. Third, we strongly recommend development of a 13C/12C isotope ratio mass spectrometry (IRMS) approach for determination of hydrolysis rates at groundwater temperatures and relevant CT and CF concentrations. The technique is sensitive enough that we expect to be able to shorten the time required for a rate-constant determination by 20-fold. Thus, a 5-year experiment conducted by the sealed-ampule approach could be shortened to 3 months by the IRMS approach. This sensitivity also would allow the IRMS technique to be used to follow hydrolysis rates at concentrations found in groundwater plumes at Hanford.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SULFATE SOLUBILITY LIMIT VERIFICATION FOR DWPF SLUDGE BATCH 7A

During processing at the Defense Waste Processing Facility (DWPF), high sulfate concentrations in the feed are a concern to DWPF as it can lead to the formation of a detrimental, sulfate-rich, molten salt phase on the surface of the glass melt pool. To avoid these issues, a sulfate concentration limit was implemented into the Product Composition Control System (PCCS). Related to SB7a frit development efforts, the Savannah River National Laboratory (SRNL) assessed the viability of using the current 0.6 wt % SO{sub 4}{sup 2-} limit set for SB6 (in glass) and the possibility of increasing the SO{sub 4}{sup 2-} solubility limit in PCCS to account for anticipated sulfur concentrations, targeted waste loadings, and inclusion of secondary streams (e.g., Actinide Removal Process (ARP)) with two recommended frits (Frit 418 and Frit 702) for SB7a processing. For a nominal SB7a blend with a 63 inch SB6 heel remaining in Tank 40 (projection SB7a-63), a 0.60 wt% SO{sub 4}{sup 2-} in glass limit was determined for waste loadings of 34 wt% up to 40 wt% with Frit 418 based on crucible melts with batched chemicals. SRNL also examined the inclusion of ARP for the same blending scenario (SB7a-63-ARP) with Frit 418 and at least a 0.6 wt% SO{sub 4}{sup 2-} level, and waste loadings of 34 wt% to 40 wt% were also acceptable. When a visible yellow and/or white sulfate salt layer was visible on the surface of any cooled glass, it was assumed to have surpassed the solubility limit of SO{sub 4}{sup 2-} for that particular composition. All of the glasses fabricated at these concentrations did not exhibit a sulfate rich salt layer on the surface of the glass melt and retained the majority of the batched SO{sub 4}{sup 2-}. At higher levels of SO{sub 4}{sup 2-} 'spiked' into the projected sludge compositions over the aforementioned interval of waste loadings, with Frit 418, low viscosity sulfur layers were observed on the surface of glass melts which confirm exceeding the solubility limit. The same sludge scenarios were also tested with Frit 702 and all glasses did not exhibit sulfur layers on the surfaces of the glass melts at spiking levels up to 0.80 wt% SO{sub 4}{sup 2-}. An ultimate SO{sub 4}{sup 2-} limit was not defined with Frit 702, but if projected SO{sub 4}{sup 2-} concentrations are expected to increase with the onset of SB7a processing, a higher limit is achievable with Frit 702 than is achievable with Frit 418. Given the anticipated concentration of SO{sub 4}{sup 2-} for SB7a, a SO{sub 4}{sup 2-} limit of 0.6 wt % SO{sub 4}{sup 2-} is recommended for processing using Frit 418. Once the confirmed SB7a composition is known and should a higher limit be needed, SRNL can re-evaluate the limit based on the actual composition and provide an updated recommendation. It has been observed that higher levels of SO{sub 4}{sup 2-} in glass can be retained with compositional changes to the frit, as was demonstrated by the glasses fabricated using Frit 702. SRNL also recommends the continuation of studies to define a more 'global' sulfate concentration limit to account for future sludge batch composition uncertainties.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Determination of the impact of glycolate on arp and mcu operations

Savannah River Remediation (SRR) is evaluating an alternate flowsheet for the Defense Waste Processing Facility (DWPF) using glycolic acid as a reductant. An important aspect of the development of the glycolic acid flowsheet is determining if glycolate has any detrimental downstream impacts. Testing was performed to determine if there is any impact to the strontium and actinide sorption by monosodium titanate (MST) and modified monosodium titanate (mMST) or if there is an impact to the cesium removal at the Modular Caustic-Side Solvent Extraction Processing Unit (MCU). Sorption testing was performed using both MST and modified MST (mMST) in the presence of 5,000 and 10,000 ppm (mass basis) glycolate. 10,000 ppm is the estimated bounding concentration expected in the DWPF recycle stream based on DWPF melter flammable gas model results. The presence of glycolate was found to slow the removal of Sr and Pu by MST, while increasing the removal rate of Np. Results indicate that the impact is a kinetic effect, and the overall capacity of the material is not affected. There was no measurable effect on U removal at either glycolate concentration. The slower removal rates for Sr and Pu at 5,000 and 10,000 ppm glycolate could result in lower DF values for these sorbates in ARP based on the current (12 hours) and proposed (8 hours) contact times. For the highest glycolate concentration used in this study, the percentage of Sr removed at 6 hours of contact decreased by 1% and the percentage of Pu removed decreased by nearly 7%. The impact may prove insignificant if the concentration of glycolate that is returned to the tank farm is well below the concentrations tested in this study. The presence of glycolate also decreased the removal rates for all three sorbates (Sr, Pu, and Np) by mMST. Similarly to MST, the results for mMST indicate that the impact is a kinetic effect, and the overall capacity of the material is not affected. The presence of glycolate did not change the lack of affinity of mMST for U. Pre-contacting the MST or mMST with glycolate did not have a significant effect on the performance of the materials when compared to tests having the same concentration of glycolate present in the simulant. These findings suggest that the glycolate is likely influencing removal by sorbate complexation and not by depositing onto or forming a film on the surface of the MST solids. Since the DF values are salt batch dependent, it is not possible to a priori quantify the impacts of glycolate on future processing campaigns. However, we recommend that the impacts of glycolate be evaluated during each salt batch qualification when a final processing concentration is defined, and recommendations can then be made on how to mitigate negative impacts, if needed. Impacts to the performance of the MST or mMST could be mitigated by increasing contact time or increasing sorbent concentrations. In addition to the MST and mMST testing, testing was performed to determine if there is an impact to the cesium removal at Modular Caustic-Side Solvent Extraction Processing Unit (MCU). An Extraction-Scrub-Strip (ESS) test routine was used to simulate cesium removal at the MCU. For this, SRNL performed three ESS tests, using the same basic aqueous waste simulant and solvent. For one test, SRNL added 5,000 ppm (mass basis) of glycolate and added 10,000 ppm of glycolate to a second test. A control test contained no glycolate. The results of all three tests were virtually identical for all the extraction, scrub and strip tests. (A single data point in the 5,000 ppm test is physically impossible and SRNL is currently resolving this obvious error.) At this time, SRNL concludes that the presence of up to 10,000 ppm of glycolate does not affect cesium removal by the current solvent system used in the MCU. Although not tested, the impact of glycolate for the Next Generation Solvent - that replaces BOBCalixC6 with MaxCalix - is expected to be very similar to that for the baseline solvent. Testing is needed to confirm. Additional testing is recommended to both further examine the nature of the interaction of glycolate with MST and mMST and also to help address some postulated risks on ARP/MCU operations with implementation of the glycolate flowsheet. The additional testing includes FTIR and Raman spectroscopy to examine the surface of the MST and mMST particles, iodometric titrations to determine the peroxide content in the mMST before and after exposure to glycolate, particle size measurements of the MST and mMST from the experiments performed with glycolate, and measurements of soluble Ti in the supernate from these glycolate experiments. With regards to MCU impacts, the following tests are also recommended based on the premortem risk assessment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

From Bombs to Breast Cancer Imaging: Los Alamos National Laboratory

In the United States, one in eight women will be affected by breast cancer. According to the American Cancer Society, breast cancer is the most commonly diagnosed - as well as the second most fatal - cancer in American women. It is estimated that there will be nearly 200,000 diagnoses of breast cancer this year; more than 40,000 of these will be fatal. Although advances in medical technologies have greatly increased the odds of surviving the disease, the increase in screenings has not resulted in a significant reduction in the breast cancer mortality rate. Moreover, recent studies have even suggested that an increase in these methods might, in itself, cause cancer. A new tool for early detection and diagnosis of breast cancer, supported by an award from the Breast Cancer Research Program (BCRP) of the Congressionally Directed Medical Research Programs of Department of Defense, could give women a new advantage in the fight against breast cancer. This LANL-led project will integrate ultrasound tomography (UST) with recent discoveries in the field of cell and tissue biomechanics to improve breast cancer detection and characterization. UST uses ultrasound waves instead of X-rays to identify and characterize breast tumors. This technology reveals small mechanical-property changes within the breast. These changes are often the earliest signs of breast cancer. Additionally, UST is effective for women with dense breast tissue, who have a higher risk of developing breast cancer. Because the technology does not use radiation, UST can also be used as frequently as needed for women with a high risk of developing breast cancer. In contrast, mammography, the only routine breast-cancer screening tool currently available, is not effective for women with dense breast tissue and may come with unwanted side-effects caused by ionizing radiation. UST has great potential to become an alternative breast-cancer screening tool because of UST's advantages and benefits over mammography. Currently, there is fierce debate surrounding the age at which breast cancer screening should begin, and once begun, how often it should occur. The American Cancer Society recommends yearly mammograms starting at age 40. On the other hand, the U.S. Preventive Services Task Force recommends against routine so early. Rather, the Task Force recommends biennial mammography screening for women aged 50 to 74 years. The ten-year discrepancy in the onset of screening results from recent data suggesting that the frequent use of X-ray radiation during screenings could potentially increase the likelihood of developing cancer. This danger is increased by the low sensitivity and accuracy of mammograms, which sometimes require multiple screenings to yield results. Furthermore, mammograms are often not only inaccurate, but average appalling misdiagnoses rates: about 80% false positives and 15% false negatives. These misdiagnoses lead to unwarranted biopsies at an estimated health care cost of $2 billion per year, while at the same time, resulting in excessive cases of undetected cancer. As such, the National Cancer Institute recommends more studies on the advantages of types and frequency of screenings, as well as alternative screening options. The UST technology developed at LANL could be an alternative option to greatly improve the specificity and sensitivity of breast cancer screening without using ionizing radiation. LANL is developing high-resolution ultrasound tomography algorithms and a clinical ultrasound tomography scanner to conduct patient studies at the UNM Hospital. During UST scanning, the patient lies face-down while her breast, immersed in a tank of warm water, is scanned by phased-transducer arrays. UST uses recorded ultrasound signals to reconstruct a high-resolution three-dimensional image of the breast, showing the spatial distribution of mechanical properties within the breast. Breast cancers are detected by higher values of mechanical properties compared to surrounding tissues. Thus, high-resolution breast images obtained using LANL's novel UST algorithms have the potential to detect breast cancer at its earliest stage. The goal of this Multi-Team Award project is two-fold: (1) develop a novel, safe and cost-effective breast-imaging technique, and (2) improve the specificity and sensitivity of breast cancer imaging. The project is expected to integrate basic research with clinical studies, perform substantive cross-disciplinary training among scientists on the teams and involve participation of consumer advocates. Those involved in the project are optimistic about future developments.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Implementation and Rejection of Industrial Steam System Energy Efficiency Measures

Steam systems consume approximately one third of energy applied at U.S. industrial facilities. To reduce energy consumption, steam system energy assessments have been conducted on a wide range of industry types over the course of five years through the Energy Savings Assessment (ESA) program administered by the U.S. Department of Energy (U.S. DOE). ESA energy assessments result in energy efficiency measure recommendations that are given potential energy and energy cost savings and potential implementation cost values. Saving and cost metrics that measure the impact recommended measures will have at facilities, described as percentages of facility baseline energy and energy cost, are developed from ESA data and used in analyses. Developed savings and cost metrics are examined along with implementation and rejection rates of recommended steam system energy efficiency measures. Based on analyses, implementation of steam system energy efficiency measures is driven primarily by cost metrics: payback period and measure implementation cost as a percentage of facility baseline energy cost (implementation cost percentage). Stated reasons for rejecting recommended measures are primarily based upon economic concerns. Additionally, implementation rates of measures are not only functions of savings and cost metrics, but time as well.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Unclonable RFID-based tag-seal for storage containers

We are using the DoD MIL-STD as our guide for microelectronics aging (MIL-STD 883J, Method 1016.2: Life/Reliability Characterization Tests). In that document they recommend aging at 3 temperatures between 200-300C, separated by at least 25C, with the supply voltage at the maximum recommended voltage for the devices at 125C (3.6V in our case). If that voltage causes excessive current or power then it can be reduced and the duration of the tests extended. The MIL-STD also recommends current limiting resistors in series with the supply. Since we don’t have much time and we may not have enough ovens and other equipment, two temperatures separated by at least 50C would be an acceptable backup plan. To ensure a safe range of conditions is used, we are executing 24-hour step tests. For these, we will apply the stress for 24 hours and then measure the device to make sure it wasn’t damaged. During the stress the PUFs should be exercised, but we don’t need to measure their response. Rather, at set intervals our devices should be returned to nominal temperature (under bias), and then measured. The MIL-STD puts these intervals at 4, 8, 16, 32, 64, 128, 256, 512 and 1000 hours, although the test can be stopped early if 75% of the devices have failed. A final recommendation per the MIL-STD is that at least 40 devices should be measured under each condition. Since we only have 25 parts, we will place 10 devices in each of two stress conditions.

25 ENERGY STORAGE↗

Measure Guideline: Internal Insulation of Masonry Walls

This measure guideline provides recommendations for interior insulation assemblies that control interstitial condensation and durability risks; recommendations for acceptable thermal performance are also provided. An illustrated guide of high-risk exterior details (which concentrate bulk water), and recommended remediation details is provided. This is followed by a recommended methodology for risk assessment of a masonry interior insulation project: a series of steps are suggested to assess the risks associated with this retrofit, with greater certainty with added steps.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Task Order 22 – Engineering and Technical Support, Deep Borehole Field Test. AREVA Summary Review Report

Under Task Order 22 of the industry Advisory and Assistance Services (A&AS) Contract to the Department of Energy (DOE) DE-NE0000291, AREVA has been tasked with providing assistance with engineering, analysis, cost estimating, and design support of a system for disposal of radioactive wastes in deep boreholes (without the use of radioactive waste). As part of this task order, AREVA was requested, through a letter of technical direction, to evaluate Sandia National Laboratory’s (SNL’s) waste package borehole emplacement system concept recommendation using input from DOE and SNL. This summary review report (SRR) documents this evaluation, with its focus on the primary input document titled: “Deep Borehole Field Test Specifications/M2FT-15SN0817091” Rev. 1 [1], hereafter referred to as the “M2 report.” The M2 report focuses on the conceptual design development for the Deep Borehole Field Test (DBFT), mainly the test waste packages (WPs) and the system for demonstrating emplacement and retrieval of those packages in the Field Test Borehole (FTB). This SRR follows the same outline as the M2 report, which allows for easy correlation between AREVA’s review comments, discussion, potential proposed alternatives, and path forward with information established in the M2 report. AREVA’s assessment focused on three primary elements of the M2 report: the conceptual design of the WPs proposed for deep borehole disposal (DBD), the mode of emplacement of the WP into DBD, and the conceptual design of the DBFT. AREVA concurs with the M2 report’s selection of the wireline emplacement mode specifically over the drill-string emplacement mode and generically over alternative emplacement modes. Table 5-1 of this SRR compares the pros and cons of each emplacement mode considered viable for DBD. The primary positive characteristics of the wireline emplacement mode include: (1) considered a mature technology; (2) operations are relatively simple; (3) probability of a radiological release due to off-normal events are relatively low; (4) costs are relatively low; and (5) maintenance activities are relatively simple. The primary drawback associated with the wireline emplacement mode for DBD is the number of emplacement trips-in to the borehole, which results in a relatively higher probability for a drop event. Fortunately, the WPs can be engineered with impact limiters that will minimize the likelihood of a breach of the WP due to a drop. The WP designs presented in the M2 report appear to be focused on compatibility with the drill-string emplacement mode (e.g., the threaded connections). With the recommendation that the wireline emplacement mode be utilized for the DBFT, some changes may be warranted to these WPs. For example, the development of a WP release connection that is more reliable than the currently credited connection, which is considered to have a high failure probability, and the integration of an impact limiter into its design. The M2 report states the engineering demonstration of the DBFT will occur in the FTB over a 4-year period. AREVA recommends development and testing of the WP emplacement handling equipment occur separately (but concurrently, if not earlier) from the FTB at a mock-up facility. The separation of this activity would prevent schedule interference between the science and engineering thrusts of the project. Performing tests in a mock-up facility would allow additional control and observation compared to the FTB. The mock-up facility could also be utilized as a training facility for future operations. Terminal velocity and impact limiter testing would require the FTB for testing, since these areas would be difficult to reproduce in a limited depth mock-up. Although only at the end of the conceptual stage of design development, DBD appears to be a viable solution for some waste forms produced by the nuclear industry. However, regulatory requirements have yet to be established for pre- and post-closure performance of DBD and should be established as soon as possible. Some of the main areas of focus from a regulatory perspective include: (1) establishing acceptable performance requirements for the long-term behavior of DBD; (2) determining acceptable borehole abandonment criteria; (3) establishing retrievability requirements; (4) developing a consensus on the factor of safety (FoS) for the emplacement mode and WP; and (5) establishing safety and safeguards performance requirements for DBD. Although conservative requirements have been utilized to provide the foundation for the conceptual design of DBD, regulatory requirements and feedback are necessary to confirm recommendations made herein and to ensure the long-term performance of DBD is acceptable. The combination of the M2 report and this SRR is intended to facilitate the completion of the conceptual design for DBD for the Cs and Sr capsules and calcined waste forms. Using the conceptual design, preliminary design activities (the second stage of a three-stage process described in the M2 report) can proceed and the DBFT utilized to support, demonstrate, and confirm engineering elements of this design.

42 ENGINEERING↗

Technologies for pre-screening IAEA swipe samples

During the course of International Atomic Energy Agency (IAEA) inspections, many samples are taken for the purpose of verifying the declared facility activities and identifying any possible undeclared activities. One of these sampling techniques is the environmental swipe sample. Due to the large number of samples collected, and the amount of time that is required to analyze them, prioritizing these swipes in the field or upon receipt at the Network of Analytical Laboratories (NWAL) will allow sensitive or mission-critical analyses to be performed sooner. As a result of this study, technologies were placed into one of three categories: recommended, promising, or not recommended. Both neutron activation analysis (NAA) and X-ray fluorescence (XRF) are recommended for further study and possible field deployment. These techniques performed the best in initial trials for pre-screening and prioritizing IAEA swipes. We learned that for NAA more characterization of cold elements (such as calcium and magnesium) would need to be emphasized, and for XRF it may be appropriate to move towards a benchtop XRF versus a handheld XRF due to the increased range of elements available on benchtop equipment. Promising techniques that will require additional research and development include confocal Raman microscopy, fluorescence microscopy, and infrared (IR) microscopy. These techniques showed substantive responses to uranium compounds, but expensive instrumentation upgrades (confocal Raman) or university engagement (fluorescence microscopy) may be necessary to investigate the utility of the techniques completely. Point-and-shoot (handheld) Raman and attenuated total reflectance–infrared (ATR-IR) measurements are not recommended, as they have not shown enough promise to continue investigations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

2015 Advanced Site Investigation and Monitoring Report Riverton, Wyoming, Processing Site September 2016

The U.S. Department of Energy conducted initial groundwater characterization of the Riverton, Wyoming, Processing Site in the 1990s. The characterization culminated in a Site Observational Work Plan in 1998 that recommended a natural flushing compliance strategy. Results of verification monitoring indicated that natural flushing was generally progressing as expected until June 2010, when significant increases in contaminant concentrations were measured in several monitoring wells downgradient of the site after the area flooded. In response to the unexpected results following the flood, an enhanced characterization of the surficial aquifer was conducted in 2012, which included installation of 103 boreholes along nine transects with a Geoprobe, collection of 103 water samples and 65 soil samples, laboratory tests on the soil samples, and additional groundwater modeling. This advanced site investigation report summarizes additional investigation in 2015 through the use of backhoe trenching, sonic drilling, multilevel monitoring wells, direct-push drilling, and temporary well points to collect soil and groundwater samples. Additional surface water measurements were made included the installation of a stilling well and the measurement of stream elevation along the Wind River to approximate upgradient groundwater heads. Groundwater sampling included the addition of geochemical constituents and isotopes that have not been sampled in the past to better understand post-flood conditions and the possibility of additional or ongoing contaminant sources. This sampling was performed to (1) better define the contaminant plumes, (2) verify the occurrence of persistent secondary contaminant sources, (3) better understand the reason for the contaminant spikes after a 2010 flood, and (4) assess contaminant plume stagnation near the Little Wind River. This report provides data analyses and interpretations for the 2015 site investigation that addresses these issues and provides recommendations for future efforts. Observations from trenches and sonic drilling indicate the general lithology of the shallow, unconsolidated sediments consists of a silt zone at the surface that ranges from 2.5 to 4.8 feet below ground surface, underlain by sand and gravel, underlain by the top of the weathered bedrock (Wind River Formation). Soil data from trenches and sonic drilling indicate (1) elevated concentrations of several constituents in the silt zone, likely due to the formation of evaporites, (2) uranium is the only measured element that appears to be concentrated in the silt over the groundwater contaminant plume, (3) in the former tailings impoundment area, there may be a thin unsaturated zone with elevated uranium in the native material just below the fill, (4) in the former tailings impoundment area, slightly higher uranium concentrations occur in the underlying saturated sand and gravel, and (5) several bedrock samples have a unique geochemical signature, generally related to a higher silt content. Assessment of groundwater flow included measuring river elevations along the Wind River and installing the temporary well points adjacent to the Little Wind River that provided additional data points to refine contours for water table elevations. These data confirm past interpretations of groundwater flow to the southeast across the site toward the Little Wind River. Hydraulic head elevations between paired surficial and semiconfined aquifer wells indicate variable vertical gradients across the site with the potential for upward and downward flow. Additional direct-push drilling and groundwater sampling confirmed the contaminant plume configuration, but it also revealed a low-sulfate-concentration zone at the edge of the former tailings impoundment. Temporary well points provided better definition of plume concentrations at the bank of the Little Wind River, and data from these wells indicate plume discharge to the river. Additional sampling in an area southwest of the plume that had elevated uranium groundwater concentrations in the past did not have any uranium concentrations above the U.S. Environmental Protection Agency maximum concentration limit for uranium. Results from multilevel monitoring wells indicate some geochemical differences with depth, but overall concentrations are similar to those in nearby conventional monitoring wells in the long-term monitoring program. Geochemistry data from these multilevel monitoring wells confirm the general increase in contaminant concentrations toward the river and toward the plume centerline for chloride, sulfate, and uranium but highlight geochemical controls on calcium. Iron data indicate slightly reducing conditions, especially near water table and bedrock surfaces, with more oxidizing conditions in the middle of the sand and gravel. Uranium activity ratios (234U/238U) confirm the uranium plume in the surficial aquifer as being mill related, and the area to the southwest outside the plume as natural, non-mill related. In the semiconfined aquifer, evidence of aquifer connection and impacts from the mill is inconclusive. Values of δD and δ 18 O suggest water is derived from different sources and tritium data confirm that the semiconfined aquifer water is generally older than the surficial aquifer water. However, these data do indicate some groundwater communication from the surficial aquifer into the semiconfined aquifer, which resulted in δD and δ 18 O and tritium values in the semiconfined aquifer that are more similar to those in the surficial aquifer. Values of δ 34 S sulfate in the semiconfined aquifer combined with sulfate concentrations indicate the potential for some mill- related sulfate in the semiconfined aquifer, albeit limited to an area near and beneath the former tailings impoundment. Uranium and molybdenum concentrations in the semiconfined aquifer are below groundwater standards in all wells. However, the elevated molybdenum concentrations at one semiconfined aquifer well underneath the former tailings impoundment suggests a mill- derived source for the uranium and molybdenum in that well. It is possible that aquifer cross- communication occurred when the tailings impoundment was active and created a higher head. Current cross-communication appears unlikely given the large differences in tritium values and an upward hydraulic head at this location. Nine domestic wells are located within the institutional control boundary (eight in the confined aquifer and one in the semiconfined aquifer). Uranium and molybdenum concentrations in all samples collected from these wells were one or two orders of magnitude below the groundwater standards. Surface water flow in the Little Wind River in September 2015 was low compared to historical averages for that time of year. As a result, the uranium concentration measured in the Little Wind River was at a historical maximum at the sampling location upstream of the site. However, the impact of uranium discharge from the groundwater plume into the Little Wind River was not measureable. Elevated sulfate concentrations were observed in an outfall ditch related to an active sulfuric acid plant. Uranium concentrations in the oxbow lake remain at concentrations above the groundwater standard. Plume contaminant concentrations had returned to levels found prior to the 2010 flood by the end of 2015. However, these concentrations still exceed model predictions for natural flushing, and the current data indicate that natural flushing to achieve remediation goals within the 100-year time period is not likely, especially with the high potential for additional floods in the update to the conceptual site model (CSM), soil data indicate additional contaminant sources, specifically uranium, in evaporites within the silt layer over the uranium plume and in naturally reduced zones (NRZs). Additional zones of slightly elevated uranium concentration are in the native sediments just above the water table but below the fill layer in the former tailings impoundment area. This area also has slightly elevated uranium in the sand and gravel below the water table. Mass balance calculations indicate that small amounts of dissolution in any of these zones with increased uranium in the solid phase can produce groundwater uranium concentrations above the groundwater standard and could account for the post-flood uranium spike. The additional uranium near the former tailings impoundment provides a mechanism for a continuing source for the uranium plume that was not considered in earlier natural flushing models. In addition, uranium released from the silt layer or the NRZs seasonally and during flooding may add uranium to the groundwater plume near the Little Wind River. These mechanisms provide a possible explanation for plume persistence, along with spikes in concentrations during floods, that creates the current plume configuration. Additional updates to the CSM include (1) chloride flushes more rapidly than uranium beneath the former mill site, (2) chloride in the silt layer provides a scenario in which chloride cannot be used as a conservative tracer (especially in areas prone to flooding), (3) uranium concentrations with depth can be variable (especially below NRZs), and (4) calcite and gypsum solubility limits appear to provide important geochemical controls on groundwater geochemistry. The conclusion of this study provides several recommendations for additional work to refine the CSM and continue assessment of the natural flushing compliance strategy. Recommendations for additional work include targeted soil and groundwater sampling to assess geochemical conditions, distribution of contaminants, and groundwater/surface water interaction; additional column tests to provide data for geochemical modeling; and development of an updated groundwater flow model, which will be used in conjunction with a geochemical model to assess the viability of the natural flushing compliance strategy.

2015 Monitoring Riverton, WY↗

Consultancy on Large-Scale Submerged Aerobic Cultivation Process Design - Final Technical Report: February 1, 2016 -- June 30, 2016

NREL is developing an advanced aerobic bubble column model using Aspen Custom Modeler (ACM). The objective of this work is to integrate the new fermentor model with existing techno-economic models in Aspen Plus and Excel to establish a new methodology for guiding process design. To assist this effort, NREL has contracted Genomatica to critique and make recommendations for improving NREL's bioreactor model and large scale aerobic bioreactor design for biologically producing lipids at commercial scale. Genomatica has highlighted a few areas for improving the functionality and effectiveness of the model. Genomatica recommends using a compartment model approach with an integrated black-box kinetic model of the production microbe. We also suggest including calculations for stirred tank reactors to extend the models functionality and adaptability for future process designs. Genomatica also suggests making several modifications to NREL's large-scale lipid production process design. The recommended process modifications are based on Genomatica's internal techno-economic assessment experience and are focused primarily on minimizing capital and operating costs. These recommendations include selecting/engineering a thermotolerant yeast strain with lipid excretion; using bubble column fermentors; increasing the size of production fermentors; reducing the number of vessels; employing semi-continuous operation; and recycling cell mass.

09 BIOMASS FUELS↗

First ARM Aerosol Chemical Speciation Monitor Users’ Meeting Report

The first U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility aerosol chemical speciation monitor (ACSM) users’ meeting was held on April 11-13, 2017, at Aerodyne Research, Inc. in Billerica, Massachusetts, to discuss the Southern Great Plains (SGP) atmospheric observatory ACSM data quality and establish best practices for data collection and processing. The participants examined six years of calibration and processed data. Specific issues raised by data users were addressed and case studies from two field experiments were examined. The most recent data from the ACSM installed in the newly commissioned SGP ARM Mobile Facility 7 (AMF7) were also evaluated. The participants recommended that the SGP ACSM data be reprocessed using calibration values averaged over the history of SGP ACSM calibrations. They also recommended that the data quality be evaluated by comparing (1) observed versus predicted particulate ammonium (NH4+) mass loadings, and (2) ACSM mass loadings versus mass loadings calculated from particle size and light scattering data. The contents of the datastreams from the ACSM were defined based on ARM requirements and the necessary tasks to implement these recommendations were assigned to the mentor and the instrument manufacturer. Some of the recommendations were implemented for the SGP data and are presented in this report. Data from two ARM sites located in marine environments were also analyzed. These analyses as well as instrument intercomparisons have led to further questions about data treatment. These will be addresses in the second users’ meeting scheduled for the summer of 2018.

54 ENVIRONMENTAL SCIENCES↗

First ARM Aerosol Chemical Speciation Monitor Users’ Meeting Report

The first U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility aerosol chemical speciation monitor (ACSM) users’ meeting was held on April 11-13, 2017, at Aerodyne Research, Inc. in Billerica, Massachusetts, to discuss the Southern Great Plains (SGP) atmospheric observatory ACSM data quality and establish best practices for data collection and processing. The participants examined six years of calibration and processed data. Specific issues raised by data users were addressed and case studies from two field experiments were examined. The most recent data from the ACSM installed in the newly commissioned SGP ARM Mobile Facility 7 (AMF7) were also evaluated. The participants recommended that the SGP ACSM data be reprocessed using calibration values averaged over the history of SGP ACSM calibrations. They also recommended that the data quality be evaluated by comparing (1) observed versus predicted particulate ammonium (NH 4 + ) mass loadings, and (2) ACSM mass loadings versus mass loadings calculated from particle size and light scattering data. The contents of the datastreams from the ACSM were defined based on ARM requirements and the necessary tasks to implement these recommendations were assigned to the mentor and the instrument manufacturer. Some of the recommendations were implemented for the SGP data and are presented in this report. Data from two ARM sites located in marine environments were also analyzed. These analyses as well as instrument intercomparisons have led to further questions about data treatment. These will be addresses in the second users’ meeting scheduled for the summer of 2018.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

First ARM Aerosol Chemical Speciation Monitor Users’ Meeting Report

The first U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility aerosol chemical speciation monitor (ACSM) users’ meeting was held on April 11-13, 2017, at Aerodyne Research, Inc. in Billerica, Massachusetts, to discuss the Southern Great Plains (SGP) atmospheric observatory ACSM data quality and establish best practices for data collection and processing. The participants examined six years of calibration and processed data. Specific issues raised by data users were addressed and case studies from two field experiments were examined. The most recent data from the ACSM installed in the newly commissioned SGP ARM Mobile Facility 7 (AMF7) were also evaluated. The participants recommended that the SGP ACSM data be reprocessed using calibration values averaged over the history of SGP ACSM calibrations. They also recommended that the data quality be evaluated by comparing (1) observed versus predicted particulate ammonium (NH 4 + ) mass loadings, and (2) ACSM mass loadings versus mass loadings calculated from particle size and light scattering data. The contents of the datastreams from the ACSM were defined based on ARM requirements and the necessary tasks to implement these recommendations were assigned to the mentor and the instrument manufacturer. Some of the recommendations were implemented for the SGP data and are presented in this report. Data from two ARM sites located in marine environments were also analyzed. These analyses as well as instrument intercomparisons have led to further questions about data treatment. These will be addresses in the second users’ meeting scheduled for the summer of 2018.

54 ENVIRONMENTAL SCIENCES↗

Solvent Hold Tank Sample Results for MCU-18-301- 303 (July 2018), MCU-18-357-359-360 (August 2018), and MCU-18-402-410 (September 2018) (Quarterly Report)

A trend summary of three Solvent Hold Tank (SHT) monthly samples; MCU-18-301-302-303, MCU-18- 357-359-360 and MCU-18-402-410 are reported. Most of the conclusions are based on the September SHT sample (MCU-18-402-410). Analyses of the September SHT sample (MCU-18-402-410) indicated that the Modifier (Cs-7SB) and the extractant (MaxCalix) concentrations were below their nominal recommended concentrations (169,000 mg/L and 46,400 mg/L respectively) by 5% and 8% respectively. The suppressor (N,N’,N”–tris(3,7-dimethyloctyl)guanidine or TiDG) concentration has decreased since the April 2018 measurement (Modular Caustic-Side Solvent Extraction Unit or MCU resumed processing radioactive salt solution from May through August 2018) to 241 mg/L, well below the minimum recommended concentration (479 mg/L). The apparent “downwards” trends observed in the TiDG, MaxCalix, and Modifier measurements are consistent with the startup (or Proficiency Runs) of MCU on May 22, 2018; new levels are consistent with the concentrations observed when MCU was fully operational in 2016. This analysis confirms the Isopar™ L addition to the solvent on July 2 and August 9, 2018. This analysis also indicates the solvent did require a trim addition. Based on the current monthly sample, the concentrations of Isopar™ L, MaxCalix, and Modifier are sufficient for continuing operation but are expected to decrease with time. The TiDG concentration was below its recommended level. Periodic characterization and trimming additions to the solvent are recommended. The Semi-Volatile Organic Analysis (SVOA) did not detect any impurities. However, the Fourier Transform Hydrogen Nuclear Magnetic Resonance (FT-HNMR) analysis detected a low concentration of sec-butyl phenol (SBP) at levels of a few ppm. The impurity concentration was highest in the July sample and consistently detected in the August and September samples (but always a few ppm or less). The source of this impurity is due to the degradation of the Modifier. Another impurity observed in the samples was mercury. Based on the September SHT sample, up to 17 ± 3 micrograms of mercury per mL of solvent was detected (the average of the Direct Mercury Analysis (DMA) and X-Ray Fluorescence (XRF) methods). The higher mercury concentration in the solvent (as determined in the last three monthly samples) is possibly due to the higher mercury concentration in Salt Batches 9 and 10 (SB 10 was recently added to Tank 49H in March 2017). The gamma concentration (~2.3E5 dpm/mL) measured in the September SHT samples was consistent with previous values observed when MCU was fully operational (for example, between December 2016 and January 2017) and it was lower than the April SHT measurement. The “dip” in the gamma measurement for the May 2018 SHT sample was due to Isopar™ L addition to MCU during April and May 2018. The laboratory will continue to monitor the quality of the solvent for any new impurities or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Corrosion Evaluation for Tank 241-AP-106 Re-purposing

Tank AP-106 will be an integral part of the Direct Feed Low Activity Waste (DF-LAW) activity. This tank is an underground, carbon steel, double shell tank (DST). Before it can be utilized, the Cs-137 concentration levels in the waste must be reduced significantly. The AP-106 re-purposing process will manage normal waste tank additions procedures such that waste acceptance criteria objectives for Cs-137 removal are achieved. As this process was being developed, concerns regarding tank integrity during and after the process to Tank AP-106 and associated tanks (i.e., AP-102, AN-101, and AP-108) were addressed. The degradation mechanisms identified include: general and pitting corrosion, caustic stress corrosion cracking, galvanic corrosion, and microbiologically induced corrosion (MIC). Recommendations were provided to minimize the exposure of the tank to corrosive conditions (see Section 6.0). These recommendations included chemistry adjustments at defined steps in the process that will maintain the waste in compliance with the corrosion control program. Additionally, sampling and inspection (see Sections 6.0 and 7.0, respectively) recommendations that will assess the final condition of the tank environment and the tank were presented. The greatest risk for this process involves the handling of large quantities of Columbia River water (i.e., greater than 450,000 gallons) within the AP-106, associated tanks and supporting infrastructure (i.e., transfer line piping). As long as this water is blended into the supernate in a timely fashion, and the waste is adjusted appropriately with corrosion inhibitors, the final condition is expected to be within compliance. Recommendations were also made to address process interruptions that could result in exposure of the tank walls to aggressive conditions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

First ARM Aerosol Chemical Speciation Monitor Users’ Meeting Report

The first U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility aerosol chemical speciation monitor (ACSM) users’ meeting was held on April 11-13, 2017, at Aerodyne Research, Inc. in Billerica, Massachusetts, to discuss the Southern Great Plains (SGP) atmospheric observatory ACSM data quality and establish best practices for data collection and processing. The participants examined six years of calibration and processed data. Specific issues raised by data users were addressed and case studies from two field experiments were examined. The most recent data from the ACSM installed in the newly commissioned SGP ARM Mobile Facility 7 (AMF7) were also evaluated. The participants recommended that the SGP ACSM data be reprocessed using calibration values averaged over the history of SGP ACSM calibrations. They also recommended that the data quality be evaluated by comparing (1) observed versus predicted particulate ammonium (NH 4 + ) mass loadings, and (2) ACSM mass loadings versus mass loadings calculated from particle size and light scattering data. The contents of the datastreams from the ACSM were defined based on ARM requirements and the necessary tasks to implement these recommendations were assigned to the mentor and the instrument manufacturer. Some of the recommendations were implemented for the SGP data and are presented in this report. Data from two ARM sites located in marine environments were also analyzed. These analyses as well as instrument intercomparisons have led to further questions about data treatment. These will be addresses in the second users’ meeting scheduled for the summer of 2018.

54 ENVIRONMENTAL SCIENCES↗