Electron Cloud at Low Emittance in CesrTA

The Cornell Electron Storage Ring (CESR) has been reconfigured as a test accelerator (CesrTA) for a program of electron cloud (EC) research at ultra low emittance. The instrumentation in the ring has been upgraded with local diagnostics for measurement of cloud density and with improved beam diagnostics for the characterization of both the low emittance performance and the beam dynamics of high intensity bunch trains interacting with the cloud. A range of EC mitigation methods have been deployed and tested and their effectiveness is discussed. Measurements of the electron cloud’s effect on the beam under a range of conditions are discussed along with the simulations being used to quantitatively understand these results.

43 PARTICLE ACCELERATORS↗

Synthesis of Fe{sub 3}O{sub 4}/SiO{sub 2}/Ag nanoparticles and its application in surface-enhanced Raman scattering

To obtain a recyclable surface-enhanced Raman scattering (SERS) material, we developed a composite of Fe{sub 3}O{sub 4}/SiO{sub 2}/Ag with core/shell/particles structure. The designed particles were synthesized via an ultrasonic route. The Raman scattering signal of Fe{sub 3}O{sub 4} could be shielded by increasing the thickness of the SiO{sub 2} layer to 60 nm. Dye rhodamine B (RB) was chosen as probe molecule to test the SERS effect of the synthesized Fe{sub 3}O{sub 4}/SiO{sub 2}/Ag particles. On the synthesized Fe{sub 3}O{sub 4}/SiO{sub 2}/Ag particles, the characteristic Raman bands of RB could be observed when the RB solution was diluted to 5 ppm (1x10{sup -5} M). Furthermore, the synthesized particles could keep their efficiency till four cycles. -- Graphical Abstract: Fe{sub 3}O{sub 4}/SiO{sub 2}/Ag particles, a recyclable surface-enhanced Raman scattering (SERS) material, were designed and synthesized via a simple ultrasonic route. Display Omitted

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Oxidation Behavior of Irradiated and Unirradiated NBG-25 Graphite

This presentation discusses The xxidation behavior of irradiated and unirradiated NBG-25 Graphite results of thermogravimetric analysis of same-source specimens from the AGC-1 experiement. Minimal annealing effects, Substantial increase in OR with Irradiation using Conventional Rate Analysis, Apparent Dose Dependency, Examination of Onset (Alternate Analysis) Shows Competing Irradiation Effects, and Similar Test Matrix (without annealing) now under way with NBG-18 Graphite is reviewed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

How does drought affect residential water demand and price elasticity?

Urban water scarcity is an important social and economic concern, particularly as the intensity, duration, and frequency of droughts is increasing in many regions. We consider whether drought induces changes to water demand and the price elasticity of demand for water that may last beyond a drought’s official end date. If drought shocks prompt long-term changes in water demand behavior, and these changes occur at broad geographic scale, they could have important implications for modeling adaptive responses to water scarcity. We assemble a novel dataset on residential water demand and pricing in the western United States to test empirically for effects of drought on water demand and price elasticity. We perform our analysis with aggregate quantity, price, and drought data, accounting for endogenous prices under increasing-block water tariffs and using both average and marginal water fees in estimating water demand functions. Results are consistent with the hypothesis that households may become less price-sensitive after exposure to drought. However, we find no systematic evidence of long-run, drought-related reductions in water demand, itself.

demand hardening↗

SiC cladding corrosion and mitigation

Silicon carbide (SiC) is a leading candidate for accident tolerant fuel. Testing of SiC in autoclaves at 360 C. degrees in simulated coolant resulted in little corrosion. However, testing of SiC tubes in the Massachusetts Institute of Technology (MIT) reactor manufactured in the same way had unacceptable corrosion levels. This in-reactor SiC corrosion issue is now being addressed by Westinghouse in tests being carried out at our Churchill, PA facility and in tests in the MIT reactor. The suspected driver for the excessive corrosion is the generation of oxidative water radiolysis products in the core. The MIT reactor was identified as running at H{sub 2} levels of ∼20 to 22 cc/kg coolant (cubic centimeters standard temperature and pressure per kilogram coolant) which were below those normally specified in operating pressurized water reactors (PWRs) of 25 to 50 cc/kg. Hydrogen is used to react with the radiolysis products to reduce them to water. The current MIT reactor tests will be run at H{sub 2} concentration levels of ∼50 cc/kg. The applicability of this approach has been supported by recent papers in the literature. Parallel testing at Churchill is being carried out to verify the efficacy of this approach using autoclaves operating at 345 C.degrees with H{sub 2}O{sub 2} injection to simulate the water radiolysis products. Various concentrations of H{sub 2} are being tested to determine the effect on SiC corrosion rate. Further studies are underway to investigate the effects of different SiC fabrication and structural parameters and to optimize for improved corrosion performance. This paper compares the results of the corrosion tests in the MIT reactor and the autoclave tests with H{sub 2}O{sub 2} injection and the effect of H{sub 2} injection on the SiC corrosion rate. The results of the autoclave tests with H{sub 2}O{sub 2} addition indicate that corrosion rates for SiC can be achieved that are much higher than those achieved in a reactor. It appears that the use of H{sub 2}O{sub 2} addition in flow through loops to simulate the corrosion rate of SiC samples in reactor is feasible. The use of H{sub 2} addition to reduce the corrosion rate in-reactor of SiC appears to be feasible.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Investigating the effect of compression on solute transport through degrading municipal solid waste

Highlights: • The influence of compression on MSW flushing was evaluated using 13 tracer tests. • Compression has little effect on solute diffusion times in MSW. • Lithium tracer was conservative in non-degrading waste but not in degrading waste. • Bromide tracer was conservative, but deuterium was not. - Abstract: The effect of applied compression on the nature of liquid flow and hence the movement of contaminants within municipal solid waste was examined by means of thirteen tracer tests conducted on five separate waste samples. The conservative nature of bromide, lithium and deuterium tracers was evaluated and linked to the presence of degradation in the sample. Lithium and deuterium tracers were non-conservative in the presence of degradation, whereas the bromide remained effectively conservative under all conditions. Solute diffusion times into and out of less mobile blocks of waste were compared for each test under the assumption of dominantly dual-porosity flow. Despite the fact that hydraulic conductivity changed strongly with applied stress, the block diffusion times were found to be much less sensitive to compression. A simple conceptual model, whereby flow is dominated by sub-parallel low permeability obstructions which define predominantly horizontally aligned less mobile zones, is able to explain this result. Compression tends to narrow the gap between the obstructions, but not significantly alter the horizontal length scale. Irrespective of knowledge of the true flow pattern, these results show that simple models of solute flushing from landfill which do not include depth dependent changes in solute transport parameters are justified.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Distribution and histologic effects of intravenously administered amorphous nanosilica particles in the testes of mice

Highlights: Black-Right-Pointing-Pointer There is rising concern regarding the potential health risks of nanomaterials. Black-Right-Pointing-Pointer Few studies have investigated the effect of nanomaterials on the reproductive system. Black-Right-Pointing-Pointer Here, we evaluated the intra-testicular distribution of nanosilica particles. Black-Right-Pointing-Pointer We showed that nanosilica particles can penetrate the blood-testis barrier. Black-Right-Pointing-Pointer These data provide basic information on ways to create safer nanomaterials. -- Abstract: Amorphous nanosilica particles (nSP) are being utilized in an increasing number of applications such as medicine, cosmetics, and foods. The reduction of the particle size to the nanoscale not only provides benefits to diverse scientific fields but also poses potential risks. Several reports have described the in vivo and in vitro toxicity of nSP, but few studies have examined their effects on the male reproductive system. The aim of this study was to evaluate the testicular distribution and histologic effects of systemically administered nSP. Mice were injected intravenously with nSP with diameters of 70 nm (nSP70) or conventional microsilica particles with diameters of 300 nm (nSP300) on two consecutive days. The intratesticular distribution of these particles 24 h after the second injection was analyzed by transmission electron microscopy. nSP70 were detected within sertoli cells and spermatocytes, including in the nuclei of spermatocytes. No nSP300 were observed in the testis. Next, mice were injected intravenously with 0.4 or 0.8 mg nSP70 every other day for a total of four administrations. Testes were harvested 48 h and 1 week after the last injection and stained with hematoxylin-eosin for histologic analysis. Histologic findings in the testes of nSP70-treated mice did not differ from those of control mice. Taken together, our results suggest that nSP70 can penetrate the blood-testis barrier and the nuclear membranes of spermatocytes without producing apparent testicular injury.

60 APPLIED LIFE SCIENCES↗

Accelerated testing of metal foil tape joints and their effect of photovoltaic module reliability.

A program is underway at Sandia National Laboratories to predict long-term reliability of photovoltaic (PV) systems. The vehicle for the reliability predictions is a Reliability Block Diagram (RBD), which models system behavior. Because this model is based mainly on field failure and repair times, it can be used to predict current reliability, but it cannot currently be used to accurately predict lifetime. In order to be truly predictive, physics-informed degradation processes and failure mechanisms need to be included in the model. This paper describes accelerated life testing of metal foil tapes used in thin-film PV modules, and how tape joint degradation, a possible failure mode, can be incorporated into the model.

14 SOLAR ENERGY↗

Effect of Gasoline Properties on Exhaust Emissions from Tier 2 Light-Duty Vehicles (Final Report: Phase 3)

This report covers work the Southwest Research Institute (SwRI) Office of Automotive Engineering has conducted for the U.S. Environmental Protection Agency (EPA), the National Renewable Energy Laboratory (NREL), and the Coordinating Research Council (CRC) in support of the Energy Policy Act of 2005 (EPAct). Section 1506 of EPAct requires EPA to produce an updated fuel effects model representing the 2007 light - duty gasoline fleet, including determination of the emissions impacts of increased renewable fuel use. This report covers the exhaust emissions testing of 15 light-duty vehicles with 27 E0 through E20 test fuels, and 4 light-duty flexible fuel vehicles (FFVs) on an E85 fuel, as part of the EPAct Gasoline Light-Duty Exhaust Fuel Effects Test Program. This program will also be referred to as the EPAct/V2/E-89 Program based on the designations used for it by the EPA, NREL, and CRC, respectively. It is expected that this report will be an attachment or a chapter in the overall EPAct/V2/E-89 Program report prepared by EPA and NREL.

02 PETROLEUM↗

Analyses of SPERT-CDC test 859 by FEMAXI-7 and RANNS codes

In the current Japanese regulation concerning fuel safety of water-cooled reactors, the criterion of fuel failure due to pellet-cladding mechanical interaction (PCMI) in a burnup range of 25-40 GWd/t is determined substantially based on the result of SPERT-CDC test 859 (SPERT859). However, there is room for discussion if the result of SPERT859 test rod with a burnup of 31.8 GWd/t represents the failure behavior of the fuel rod for commercial light water reactor because it was reported in some literatures that the cladding of SPERT859 test rod corroded excessively during pre-irradiation. On the other hand, the oxide thickness on the cladding of SPERT859 test rod was not reported in the data of its post-irradiation examinations (PIEs) after pre-irradiation, and the probability of the excessive corrosion on the cladding of the test rod and the effect of such excessive corrosion on the fuel enthalpy at failure of the test rod has not yet been clarified. In this study, the oxide thickness of the cladding formed on the cladding outer surface of SPERT859 test rod and its fuel enthalpy at failure due to PCMI under this corrosion condition were analyzed by using fuel performance codes FEMAXI-7 and RANNS. From the analysis results of FEMAXI-7, it was found that the excessive corrosion of the cladding of the test rod should be assumed to reproduce the fuel outer diameter measured in PIEs after pre-irradiation. The fuel enthalpy at failure of the test rod was calculated by using RANNS, and the calculated fuel enthalpy at failure was relatively close to the value of SPERT859 test rod. These results suggested that the fuel enthalpy at failure of SPERT859 was affected by the excessive corrosion on the cladding of the test rod and was likely lower than that of the typical fuel for light water reactors. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Planning Roadmap for DER Integration in India: Industry Best Practices and Resource Guide

Ensuring safe, reliable, cost-effective DER integration at scale requires holistic planning, broad stakeholder engagement, and should address key development areas such as standards adoption, equipment testing and certification, interoperability and cybersecurity, interconnection procedures, and advanced forecasting and DER management. Each of these areas currently represent significant challenges for utilities, regulators, OEMs, developers, and even consumers worldwide. India has already seen significant growth of DERs and has announced targets for substantial growth yet to come, with the potential for DERs to make up a non-negligible portion of the country's overall generation capacity. As such, it is of critical importance that Indian stakeholders consider the potential impacts of wide-spread adoption of DERs and take preemptive action related to the five development areas listed here, among others. India should consider strategies including the adoption of key DER standards related to interconnection, testing, and cybersecurity; enabling effective and secure communication channels for DER interoperability; testing and certifying DER equipment in accredited testing laboratories; building robust, streamlined interconnection procedures; and revamping legacy system planning structures to incorporate DERs in a holistic planning framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Size Scaling of Tensile Failure Stress in a Soda-Lime-Silicate Float Glass

The (tensile) strength-size scaling of a float soda-lime silicate glass was studied using biaxial flexure and Hertzian ring crack initiation testing. The examined Weibull effective areas spanned ~ 0.4 to 48,000 mm2. Both the air- and tin-sides were tested. The air side was stronger than the tin side as others have observed; however, the differences in their characteristic strengths decreased with decreasing effective area, and their strengths converged for effective areas smaller than ~ 100 mm2. The failure stress at the smallest effective area examined for the tin-side was ~ 500% greater than that at the largest effective area while that difference was ~ 250% for the air- side. A Weibull modulus change at ~ 100 mm2 suggests different strength-limiting flaw types were dominant below and above that effective area. These results reinforce the importance to interpret and use tensile strength of glass in context to how much of its area is being tensile stressed.

36 MATERIALS SCIENCE↗

Testing eternal inflation with the kinetic Sunyaev Zel'dovich effect

Perhaps the most controversial idea in modern cosmology is that our observable universe is contained within one bubble among many, all inhabiting the eternally inflating multiverse. One of the few way to test this idea is to look for evidence of the relic inhomogeneities left by the collisions between other bubbles and our own. Such relic inhomogeneities will induce a coherent bulk flow over Gpc scales. Therefore, bubble collisions leave unique imprints in the cosmic microwave background (CMB) through the kinetic Sunyaev Zel'dovich (kSZ) effect, temperature anisotropies induced by the scattering of photons from coherently moving free electrons in the diffuse intergalactic medium. The kSZ signature produced by bubble collisions has a unique directional dependence and is tightly correlated with the galaxy distribution; it can therefore be distinguished from other contributions to the CMB anisotropies. An important advantage of the kSZ signature is that it peaks on arcminute angular scales, where the limiting factors in making a detection are instrumental noise and foreground subtraction. This is in contrast to the collision signature in the primary CMB, which peaks on angular scales much larger than one degree, and whose detection is therefore limited by cosmic variance. In this paper, we examine the prospects for probing the inhomogeneities left by bubble collisions using the kSZ effect. We provide a forecast for detection using cross-correlations between CMB and galaxy surveys, finding that the detectability using the kSZ effect can be competitive with constraints from CMB temperature and polarization data.

79 ASTRONOMY AND ASTROPHYSICS↗

STRONTIUM AND ACTINIDE SORPTION BY MST AND MMST UNDER CONDITIONS REVELANT TO THE SMALL COLUMN ION-EXCHANGE PROCESS

A series of tests were performed to examine the kinetics of Sr and actinide removal by monosodium titanate (MST) and modified monosodium titanate (mMST) under mixing conditions similar to what will be provided in the Small Column Ion Exchange (SCIX) Program. Similar removal kinetics were seen for two different mixing energies, indicating that under these conditions bulk solution transport is not the rate limiting step for Sr and actinide removal. Sr removal was found to be rapid for both MST and mMST, reaching steady-state conditions within six hours. In contrast, at least six weeks is necessary to reach steady-state conditions for Pu with MST. For mMST, steady-state conditions for Pu were achieved within two weeks. The actual contact time required for the SCIX process will depend on starting sorbate concentrations as well as the requirements for the decontaminated salt solution. During testing leaks occurred in both the MST and mMST tests and evidence of potential desorption was observed. The desorption likely occurred as a result of the change in solids to liquid phase ratio that occurred due to the loss of solution. Based on these results, Savannah River National Laboratory (SRNL) recommended additional testing to further study the effect of changing phase ratios on desorption. This testing is currently in progress and results will be documented in a separate report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Interpretation of Colloid-Homologue Tracer Test 10-03, Including Comparisons to Test 10-01

This presentation covers the interpretations of colloid-homologue tracer test 10-03 conducted at the Grimsel Test Site, Switzerland, in 2010. It also provides a comparison of the interpreted test results with those of tracer test 10-01, which was conducted in the same fracture flow system and using the same tracers than test 10-03, but at a higher extraction flow rate. A method of correcting for apparent uranine degradation in test 10-03 is presented. Conclusions are: (1) Uranine degradation occurred in test 10-03, but not in 10-01; (2) Uranine correction based on apparent degradation rate in injection loop in test 11-02 seems reasonable when applied to data from test 10-03; (3) Colloid breakthrough curves quite similar in the two tests with similar recoveries relative to uranine (after correction); and (4) Much slower apparent desorption of homologues in test 10-03 than in 10-01 (any effect of residual homologues from test 10-01 in test 10-03?).

54 ENVIRONMENTAL SCIENCES↗

In-Sodium Testing of a Prototype Thermoacoustic Power Sensor for Sodium-Cooled Fast Reactors

The ultimate goal of this project is to develop and demonstrate a thermoacoustic power sensor (TAPS) for Sodium-Cooled Fast Reactors (SFRs), with potential application also envisioned to other nuclear technologies such as Lead-Cooled Fast Reactors (LFRs), Molten Salt Reactors (MSRs), in addition to Light Water Reactors (LWRs). The project was led by Westinghouse Electric Company, LLC (Westinghouse) and carried out in collaboration with Argonne National Laboratory (ANL) and the University of Pittsburgh. A TAPS is a passive (self-powered), non-invasive (wireless) sensor envisioned for measuring key parameters, such as local temperature and neutron flux, in a nuclear reactor core. The sensor generates pressure waves (i.e., sound waves) with a frequency and amplitude dependent upon nuclear operating conditions (coolant temperature or power changes). The acoustic waves are able to travel through the core and associated structures, and reach to the sensor network placed outside and/or inside of the reactor vessel. These sensors require a very small amount of power which, during loss of power events, can be provided, for example, by harvesting gamma radiation energy, thus resulting in a monitoring system that can function both during normal operation and during loss of power events. Westinghouse and the University of Pittsburgh designed and fabricated TAPS prototypes for Argonne National Laboratory (ANL) to carry out in-sodium testing to evaluate the effects of sodium on the TAPS and the performance of the TAPS technique in sodium. Argonne received a TAPS prototype from Westinghouse, and the prototype was modified such that it can be installed into a test vessel and function in sodium at elevated temperature without potentially leaking. A water mockup test apparatus was constructed to validate proper working of the prototype. An instrumentation and control (I&C) system, running on the National Instruments (NI) LabView platform, was developed to: 1) operate both the water mockup test and the in-sodium test facility; and 2) process and analyze the received acoustic signals from an array of accelerometers and the Argonne sodium-submersible high-temperature acoustic sensor. The prototype was successfully tested in a water bath at different temperatures. Water mockup tests demonstrated that the TAPS prototype is working properly and its resonance frequency changes linearly with the coolant (water) temperature. A TAPS test apparatus was constructed and integrated with the upgraded Under-Sodium Viewing (USV) sodium test facility. The integrated USV-TAPS sodium test facility has been operational. The TAPS prototype and a high-temperature sodium-submersible acoustic sensor (SSAS) developed by Argonne were both installed inside the TAPS test vessel. Being operated within argon cover gas under ambient conditions, the TAPS prototype demonstrated that it was functioning properly with a resonance frequency at 1407.2 Hz, which was successfully detected by the accelerometers mounted on the external wall of the vessel and the high-temperature SSAS installed inside the vessel. After successfully transferring sodium into the vessel, in-sodium tests of the prototype were conducted. Tests of the TAPS prototype demonstrated that the resonance frequency of the TAPS changes linearly with respect to the temperature difference between the interior of the TAPS and bulk sodium. The early tests showed that the TAPS prototype could not establish a continuous and consistent resonance in sodium. The resonance diminished before the prototype reached its operating temperature. A signal postprocessor was added to the DAQ module latterly to isolate interferences, enhance signal conditioning, improve peak detection, and generate resonance frequency versus temperature plots. After testing in molten sodium and immersion at higher temperature for several weeks, the TAPS prototype was able to establish a continuous resonance. Performance evaluation of the TAPS prototype was then conducted in sodium. The tests included the investigation of 1) the effects of the temperature difference between the TAPS and bulk sodium, 2) the effects of sodium flowrate; and 3) the performance of the different sensor-receiver systems positioned inside or outside the vessel. Results of a test demonstrated that, with limited sodium circulation, a continuous and consistent resonance of the TAPS prototype was established occasionally. The tests also demonstrated that, because of the nature of detection principles and mounting methods, the high temperature SSAS is more affected by acoustic noise, while accelerometers are more affected by vibrations, in the test environment. It is unknown why the TAPS prototype only occasionally established a continuous and consistent resonance when the TAPS temperature reached its operating temperature in molten sodium, and why it ultimately failed to resonate at all. A failure modes assessment was conducted and a few potential causes of failure were identified. Different post in-sodium tests were conducted to obtain additional information potentially relevant to the cause of the failure. Nondestructive evaluation techniques are suggested to examine the internal integrity as well as the gas mixture of the prototype. If they prove inconclusive, the prototype should be cut open to conduct a thorough inspection of its internal integrity and determine the state of the gas mixture.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗