Search NASA⌕ Search

SEARCH · Search NASA

Results for “Inverter Controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Modular Isolated Soft-Switching Medium Voltage String Inverter for Large-Scale PV Farm

This paper presents a single-stage modular isolated soft-switching medium voltage string inverter (MVSI) with tri-port configuration to interconnect PV and storage to medium voltage (MV) grid. The modular MVSI provides advanced functionalities such as energy storage elements integration without additional converters, connection to MV grid resulting in lower distribution losses in the PV farm, high-frequency galvanic isolation, independent control of PV, storage and grid power, high modularity and scalability. The topology of the MVSI, operation principle and model-predictive priority-switching (MPPS) control to achieve fast dynamic balancing across stacked modules are discussed. The independent power control is validated in PLECS simulation and the operation of stacked MVSI with MPPS control is verified through Hardware-in-the-loop (HIL) simulation. Here, the hardware prototype of 25 kVA MVSI building block is developed. 18 kW experimental results of single building block verifying tri-ports operation and 20 kW experimental results of two modules stacked operation are presented. A clean sinusoidal waveform with negligibly low THD in both tests is obtained. A low dv/dt of <; 1kV/us and soft-switching are achieved.

30 DIRECT ENERGY CONVERSION↗

Adapting confocal Raman microscopy for in situ studies of redox transformations at electrode-electrolyte interfaces

Confocal Raman microscopy was applied to quantify redox species present within the diffusion layer adjacent to an electrode surface under potentiostatic control. A glass microscope coverslip with a thin indium tin oxide (ITO) coating served as both the working electrode and optical window for a microscope-stage mountable spectroelectrochemical cell. A high numerical aperture objective mounted in an inverted microscope frame just below the stage brought excitation radiation through the coverslip window and to a tight focus a few micrometers above the ITO film surface. Species diffusing into the confocal probe volume defined by the excitation beam focus and the collected light region were detected, identified and quantified based on their Raman scattering frequencies and intensities. Here, in measurements that interrogated the interconversion of ferrocyanide and ferricyanide ions as a function of applied voltage, least-squares regression analysis of spectral datasets predicted the formal potential and relative surface concentrations of the ions in good agreement with the expected Nernstian response. Preliminary studies of methyl viologen reduction at an ITO film/Nafion membrane interface were conducted and show the possibility for estimation of mass transport coefficients of redox species within ionic polymer materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Domain wall-magnetic tunnel junction spin–orbit torque devices and circuits for in-memory computing

There are pressing problems with traditional computing, especially for accomplishing data-intensive and real-time tasks, that motivate the development of in-memory computing devices to both store information and perform computation. Magnetic tunnel junction memory elements can be used for computation by manipulating a domain wall, a transition region between magnetic domains, but the experimental study of such devices has been limited by high current densities and low tunnel magnetoresistance. Here, we study prototypes of three-terminal domain wall-magnetic tunnel junction in-memory computing devices that can address data processing bottlenecks and resolve these challenges by using perpendicular magnetic anisotropy, spin–orbit torque switching, and an optimized lithography process to produce average device tunnel magnetoresistance TMR = 171% and average resistance-area product RA = 29 Ω μm2, close to the RA of the unpatterned film. Device initialization variation in switching voltage is shown to be curtailed to 7%–10% by controlling the domain wall initial position, which we show corresponds to 90%–96% accuracy in a domain wall-magnetic tunnel junction full adder simulation. Repeatability of writing and resetting the device is shown. A circuit shows an inverter operation between two devices, showing that a voltage window is large enough, compared to the variation noise, to repeatably operate a domain wall-magnetic tunnel junction circuit. These results make strides in using magnetic tunnel junctions and domain walls for in-memory and neuromorphic computing applications.

Alamdar, Mahshid (ORCID:0000000221732935)↗

The ANACONDA algorithm for deformable image registration in radiotherapy

Purpose: The purpose of this work was to describe a versatile algorithm for deformable image registration with applications in radiotherapy and to validate it on thoracic 4DCT data as well as CT/cone beam CT (CBCT) data. Methods: ANAtomically CONstrained Deformation Algorithm (ANACONDA) combines image information (i.e., intensities) with anatomical information as provided by contoured image sets. The registration problem is formulated as a nonlinear optimization problem and solved with an in-house developed solver, tailored to this problem. The objective function, which is minimized during optimization, is a linear combination of four nonlinear terms: 1. image similarity term; 2. grid regularization term, which aims at keeping the deformed image grid smooth and invertible; 3. a shape based regularization term which works to keep the deformation anatomically reasonable when regions of interest are present in the reference image; and 4. a penalty term which is added to the optimization problem when controlling structures are used, aimed at deforming the selected structure in the reference image to the corresponding structure in the target image. Results: To validate ANACONDA, the authors have used 16 publically available thoracic 4DCT data sets for which target registration errors from several algorithms have been reported in the literature. On average for the 16 data sets, the target registration error is 1.17 ± 0.87 mm, Dice similarity coefficient is 0.98 for the two lungs, and image similarity, measured by the correlation coefficient, is 0.95. The authors have also validated ANACONDA using two pelvic cases and one head and neck case with planning CT and daily acquired CBCT. Each image has been contoured by a physician (radiation oncologist) or experienced radiation therapist. The results are an improvement with respect to rigid registration. However, for the head and neck case, the sample set is too small to show statistical significance. Conclusions: ANACONDA performs well in comparison with other algorithms. By including CT/CBCT data in the validation, the various aspects of the algorithm such as its ability to handle different modalities, large deformations, and air pockets are shown.

60 APPLIED LIFE SCIENCES↗

Models and methods for assessing the value of HVDC adn MVDC technologies in modern power grids (Annual Report, Executive Summary)

Evolution of today’s predominantly alternating current (ac) transmission grid in to mixed ac transmission – high-voltage direct current (HVdc) systems is expected with the decreasing costs of and advancements in power electronics technologies. The recent technological advancements include the development of more efficient and compact voltage source converters (VSCs) that can provide fast response. Because of their controllability and fast response, HVdc systems provide the ability to enhance reliability of the ac transmission grid through frequency support, voltage control, and congestion relief. The HVdc systems can also provide other ancillary services to enhance the economics and reliability of the ac transmission grids, and to optimize their performance. The tools, models, and methods developed to evaluate their benefits will be key enablers to understanding the value proposition introduced by the fast-acting HVdc systems. The main motivation of this work was to develop models and methods to explore and quantify the technical and economic benefits of HVdc systems and fast response VSC technologies in the future grid of United States. The models and methods explore the benefits of HVdc systems through provision of controlled active/reactive power and fast response. The fast response can provide much-needed multiobjective services to the grid (e.g., frequency response, voltage control) while moving blocks of energy. The models and methods can be applied to study other power electronics technologies and scenarios such as those undertaken in ongoing studies led by the North American Electric Reliability Corporation (NERC) Inverter-based Resource Performance Task Force (IRPTF). The IRPTF studies identify the problems associated with power electronics-based technologies as they are integrated in to the bulk power system (or the ac transmission system).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improvements in and test results for the 2 to 15 kilowatt Brayton cycle electrical subsystem

The electrical subsystem of the 2- to 15-kW Brayton power conversion system consists of the auxiliary electrical equipment required for an integrated, self-contained system. For the last 2 years the electrical subsystem has been undergoing extensive tests. The first year of testing resulted in determining the performance characteristics of the electrical subsystem. During the second year several significant changes and improvements were investigated. An inverter designed for motor starting the alternator performed successfully. Some of the changes that have been made are a new alternator speed pickup, which is independent of the alternator output voltage; new, more efficient power supplies for the control system; and a volts-per-hertz reference for the alternator voltage regulator. Test data were taken on the temperature distribution of the electrical subsystem at startup conditions over a cold-plate temperature range of 25 to -50 C.

Vrancik, J. E.↗

Parallel processing spacecraft communication system

An uplink controlling assembly speeds data processing using a special parallel codeblock technique. A correct start sequence initiates processing of a frame. Two possible start sequences can be used; and the one which is used determines whether data polarity is inverted or non-inverted. Processing continues until uncorrectable errors are found. The frame ends by intentionally sending a block with an uncorrectable error. Each of the codeblocks in the frame has a channel ID. Each channel ID can be separately processed in parallel. This obviates the problem of waiting for error correction processing. If that channel number is zero, however, it indicates that the frame of data represents a critical command only. That data is handled in a special way, independent of the software. Otherwise, the processed data further handled using special double buffering techniques to avoid problems from overrun. When overrun does occur, the system takes action to lose only the oldest data.

Bolotin, Gary S.↗

Interference effects in the high-order harmonic amplification process in the active medium of a plasma-based X-ray laser modulated by an optical field

We study the process of propagation of high harmonics of optical radiation in an active medium of a plasma-based X-ray laser, simultaneously irradiated by an intense optical field of fundamental frequency. It is shown that for moderate plasma dispersion of the active medium at the frequency of the modulating optical field, the energy and relative amplitudes of the harmonics at the output of the medium are determined by their phases at the entrance to the medium, as well as by the time-delay of the harmonics with respect to the modulating field. These dependences are due to interference of high-order harmonics with a set of multi-frequency fields generated by each of the harmonics in the process of coherent scattering in a modulated active medium. The possibilities of using these effects to increase the efficiency of harmonic amplification, to control the harmonic spectrum, and determine the relative phases at the entrance to the medium are discussed on the example of the active medium of hydrogen-like Li{sup 2+} ions (with a 13.5 nm wavelength of an inverted transition). (paper)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Methods and apparatus for gnotobiotic plant growth

The disclosure relates to a plant growth apparatus and related system to grow and maintain plants under controlled biotic conditions, for example to grow axenic (microbe-free) plants, gnotobiotic (defined microbiota) plants, and holoxenic (complex, or undefined microbiota) plants. This system allows aseptic bottom irrigation with water, soluble nutrients, chemicals, and/or microbiota. Plants can be inverted for dipping and/or vacuum infiltration. The system also allows for passive (gravity) drainage, thereby allowing for gas exchange and preventing root anoxia. A variety of plant growth substrates can be used within the plant growth apparatus as a plant growth medium. The plant growth apparatus, containing the growth substrate medium, can be completely flushed via the drainage port to remove potential toxic byproducts of the sterilization processes. The entire system is suitably constructed using autoclavable material.

59 BASIC BIOLOGICAL SCIENCES↗

Direct Phase-Angle Detection for Three-Phase Inverters in Asymmetrical Power Grids

This paper introduces a signal reformation based direct phase-angle detection (DPD-SR) technique for three-phase inverters supporting asymmetrical grids. Asymmetries in three-phase systems may happen because of unbalanced three-phase loads, which can lead to the voltage asymmetry at the terminals of grid-tied inverters. The proposed DPD-SR technique can detect the voltage phase-angle under asymmetrical conditions. The DPD-SR technique also offers precise and rapid phase-angle detection via signal reformation and trigonometric functions. In essence, the phase-angle detection is directly derived from the trigonometric properties of the line-line voltages, while signal reformation is implemented to handle asymmetrical voltages. The proposed method measures two line-line voltages and detects the phase-angle of a three-phase system under both symmetrical and asymmetrical conditions. Unlike classical phase-locked loop (PLL) techniques, DPD-SR does not need any closed-loop PI controller, which significantly reduces the complexity and the delay in detecting the phase-angle. In this paper, the efficacy of the proposed technique is examined in comparison with the state-of-the-art PLLs under asymmetrical conditions via a set of laboratory experiments. Here, the performance of the phase-angle detection is also tested as part of an inverter feeding an asymmetrical grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Study of the Protection Improvements for a Weak Grid Area With High Inverter-Based Resources (IBRs)

This project designs enhanced protection scheme for the real-world weak grid area with a high penetration of IBRs. As the existing protection schemes are originally designed for traditional synchronous machines, we first evaluate if the protection scheme will continue to operate reliably in systems with high levels of IBRs. Hardware relays are tested using a controller-hardware-in-the-loop setup. PSCAD electromagnetic transient simulation with IBR original equipment manufacturer black-box models is used to perform fault studies and generate COMTRADE data, which are replayed by a real-time digital simulator (RTDS) to feed input to the hardware relays. Three scenarios are analyzed: normal operation, an N-1 contingency, and an IBR-only scenario. The evaluation results reveal the following: 1) the protection scheme remains reliable under normal conditions and N-1 contingencies and 2) in IBR-only scenarios, differential protection (87L) continues to operate reliably, whereas local protection elements, such as distance and directional elements, fail because of the lack of regulated negative sequence current contributed by IBRs. Enhanced protection is designed to address the challenge of lack of negative sequence current from IBRs, including increased restraining factors a2 and k2 to block 32Q or using V instead QV ORDER for ground faults, enhanced mho distance element with voltage and phase angle supervision for L-L faults. The efficacy of enhanced protection logic is validated and proven to work reliably. Additionally, IEEE Std. 2800-2022 negative sequence current compliant GFL and GFM IBRs from another vendor are tested and proven to work reliably without need for enhanced logic. Therefore, this work provides valuable decision-making for utilities facing protection system challenges due to IBRs, either designing enhanced protection scheme or requesting their IBRs being IEEE Std. 2800-2022 compliant to produce regulated negative sequence current for protection relay to make correct decision.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A designed bacterial microcompartment shell with tunable composition and precision cargo loading

Microbes often augment their metabolism by conditionally constructing proteinaceous organelles, known as bacterial microcompartments (BMCs), that encapsulate enzymes to degrade organic compounds or assimilate CO 2 . BMCs self-assemble and are spatially delimited by a semi-permeable shell made up of hexameric, trimeric, and pentameric shell proteins. Bioengineers aim to recapitulate the organization and efficiency of these complex biological architectures by redesigning the shell to incorporate non-native enzymes from biotechnologically relevant pathways. To meet this challenge, a diverse set of synthetic biology tools are required, including methods to manipulate the properties of the shell as well as target and organize cargo encapsulation. We designed and determined the crystal structure of a synthetic shell protein building block with an inverted sidedness of its N- and C-terminal residues relative to its natural counterpart; the inversion targets genetically fused protein cargo to the lumen of the shell. Moreover, the titer of fluorescent protein cargo encapsulated using this strategy is controllable using an inducible tetracycline promoter. Furthermore, these results expand the available set of building blocks for precision engineering of BMC-based nanoreactors and are compatible with orthogonal methods which will facilitate the installation and organization of multi-enzyme pathways.

59 BASIC BIOLOGICAL SCIENCES↗

High-dimensional maximum-entropy phase space tomography using normalizing flows

Particle accelerators generate charged-particle beams with tailored distributions in six-dimensional position-momentum space (phase space). Knowledge of the phase space distribution enables model-based beam optimization and control. In the absence of direct measurements, the distribution must be tomographically reconstructed from its projections. In this paper, we highlight that such problems can be severely underdetermined and that entropy maximization is the most conservative solution strategy. We leverage —invertible generative models—to extend maximum-entropy tomography to six-dimensional phase space and perform numerical experiments to validate the model's performance. Our numerical experiments demonstrate consistency with exact two-dimensional maximum-entropy solutions and the ability to fit complicated six-dimensional distributions to large measurement sets in reasonable time. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Hardware Demonstration of Weak Grid Oscillations in Grid-Following Converters

The increasing penetration of inverter-based resources (IBRs) introduces some unexpected dynamic issues, including low-frequency oscillations. In this paper, a laboratory-scale grid-following voltage-source converter (VSC) system is implemented to demonstrate weak grid oscillations. Grid-following control is applied in VSC to provide active power, reactive power or ac voltage control. The test bed is also replicated in electromagnetic transient (EMT) simulation environment (MAT-LAB/SimPowerSystems) for benchmark purpose. Case studies are carried out to demonstrate low-frequency oscillations under real power/ac voltage or real power/reactive power control. The excellent agreement between the simulation and experimental results ensures that the two test beds are exchangeable and can be used for testing oscillation mitigation strategies in future research.

Bao, Li↗