Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optimality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Global stellarator coil optimization with quadratic constraints and objectives

Most present stellarator designs are produced by costly two-stage optimization: the first for an optimized equilibrium, and the second for a coil design reproducing its magnetic configuration. Few proxies for coil complexity and forces exist at the equilibrium stage. Rapid initial state finding for both stages is a topic of active research. Most present convex coil optimization codes use the least square winding surface method by Merkel (NESCOIL), with recent improvements in conditioning, regularization, sparsity, and physics objectives. While elegant, the method is limited to modeling the norms of linear functions in coil current. We present QUADCOIL, a global coil optimization method that targets combinations of linear and quadratic functions of the current. It can directly constrain and/or minimize a wide range of physics objectives unavailable in NESCOIL and REGCOIL, including the Lorentz force, magnetic energy, curvature, field-current alignment, and the maximum density of a dipole array. QUADCOIL requires no initial guess and runs nearly $10$ 2 x faster than filament optimization. Integrating it in the equilibrium optimization stage can potentially exclude equilibria with difficult-to-design coils, without significantly increasing the computation time per iteration. QUADCOIL finds the exact, global minimum in a large parameter space when possible, and otherwise finds a well-performing approximate global minimum. It supports most regularization techniques developed for NESCOIL and REGCOIL. We demonstrate QUADCOIL’s effectiveness in coil topology control, minimizing non-convex penalties, and predicting filament coil complexity with three numerical examples.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Robust entanglement in antiferromagnetic Heisenberg chains by single-spin optimal control

We demonstrate how near-perfect entanglement (in fact arbitrarily close to maximal entanglement) can be generated between the end spins of an antiferromagnetic isotropic Heisenberg chain of length N, starting from the ground state in the N/2 excitation subspace, by applying a magnetic field along a given direction, acting on a single spin only. Temporally optimal magnetic fields to generate a singlet pair between the two end spins of the chain are calculated for chains up to length 20 using optimal control theory. The optimal fields are shown to remain effective in various nonideal situations including thermal fluctuations, magnetic field leakage, random system couplings, and decoherence. Furthermore, the quality of the entanglement generated can be substantially improved by taking these imperfections into account in the optimization. In particular, the optimal pulse of a given thermal initial state is also optimal for any other initial thermal state with lower temperature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Chopped random-basis quantum optimization

In this work, we describe in detail the chopped random basis (CRAB) optimal control technique recently introduced to optimize time-dependent density matrix renormalization group simulations [P. Doria, T. Calarco, and S. Montangero, Phys. Rev. Lett. 106, 190501 (2011)]. Here, we study the efficiency of this control technique in optimizing different quantum processes and we show that in the considered cases we obtain results equivalent to those obtained via different optimal control methods while using less resources. We propose the CRAB optimization as a general and versatile optimal control technique.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimization of Medium Frequency Transformers with Practical Considerations

A method to design and optimize a Medium Frequency Transformer (MFT) based on commercially available components and semiconductor and converter constraints is presented. The optimization algorithm is used to redesign the transformer for a scaled-down electric vehicle (EV) fast charger using a three-level resonant circuit topology. The main consideration of this paper is the uncertainty caused by modeling assumptions in optimization algorithms. To reduce this uncertainty, space mapping is used to create an optimized design point. Lastly, a comparison of the designs found using the original optimization algorithm and the space mapping technique are compared and analyzed. For simplicity, only a single objective optimization routine is employed.

42 ENGINEERING↗

Optimal Energy Dispatch of Distributed PVs for the Next Generation of Distribution Management Systems

Advanced Distribution Management Systems (ADMS) are being widely adopted by electric utilities for managing and optimizing the operations of their distribution systems. Distributed photovoltaic (DPV) systems with smart inverters can be controlled to adjust active power and reactive power outputs, and they are envisioned to become a part of (centrally or distributed) controllable assets managed by the ADMS for optimizing grid operations. This paper proposes an optimal energy dispatch strategy controlling DPV systems for regulating distribution voltages and achieving conservation voltage reduction. A convex optimization model is proposed with the use of linearized power flow, and the gradient projection algorithm is used to solve the optimal active power and reactive power outputs of smart inverters. The proposed optimal energy dispatch is implemented using an open-source ADMS platform, and simulation results have demonstrated the effectiveness of the proposed approach on improving distribution grid operations.

42 ENGINEERING↗

Dual Representations and H ∞ -Optimal Control of Partial Differential Equations

We consider H ∞ -optimal state-feedback control of the class of linear Partial Differential Equations (PDEs) which admit a Partial Integral Equation (PIE) representation. While linear matrix inequalities are commonly used for optimal control of Ordinary Differential Equations (ODEs), the absence of a universal state-space representation and suitable dual form prevents such methods from being applied to optimal control of PDEs. Specifically, for ODEs, the controller synthesis problem is defined in state-space, and duality is used to resolve the bilinearity of that synthesis problem. Recently, the PIE representation was proposed as a universal state-space representation for linear PDE systems. In this paper, we show that any PDE system represented by a PIE admits a dual PIE with identical stability and I/O properties. This result allows us to reformulate the stabilizing and optimal state-feedback control problems as convex optimization over the cone of positive Partial Integral (PI) operators. Operator inversion formulae then allow us to construct feedback gains for the original PDE system. The results are verified through application to several canonical problems in optimal control of PDEs and indicate the resulting bounds on H ∞ norm are not conservative.

42 ENGINEERING↗

Online Optimization as a Feedback Controller: Stability and Tracking

This paper develops and analyzes feedback-based online optimization methods to regulate the output of a linear time-invariant (LTI) dynamical system to the optimal solution of a time-varying convex optimization problem. The design of the algorithm is based on continuous-time primal-dual dynamics, properly modified to incorporate feedback from the LTI dynamical system, applied to a proximal augmented Lagrangian function. The resultant closed-loop algorithm tracks the solution of the time-varying optimization problem without requiring knowledge of (time-varying) disturbances in the dynamical system. The analysis leverages integral quadratic constraints to provide linear matrix inequality (LMI) conditions that guarantee global exponential stability and bounded tracking error. Analytical results show that, under a sufficient time-scale separation between the dynamics of the LTI dynamical system and the algorithm, the LMI conditions can be always satisfied. The paper further proposes a modified algorithm that can track an approximate solution trajectory of the constrained optimization problem under less restrictive assumptions. As an illustrative example, the proposed algorithms are showcased for power transmission systems, to compress the time scales between secondary and tertiary control, and allow to simultaneously power re-balancing and tracking of DC optimal power flow points.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cooperative Game Approach to Optimal Merging Sequence and On-Ramp Merging Control of Connected and Automated Vehicles

Vehicle merging is one of the main causes of reduced traffic efficiency, increased risk of collision, and fuel consumption. Connected and automated vehicles (CAVs) can improve traffic efficiency, increase safety, and reduce the negative environmental impacts through effective communication and control. Therefore, to improve the traffic efficiency and reduce the fuel consumption in on-ramp scenarios, this paper addresses the global and optimal coordination of the CAVs in a merging zone. In this work, a cooperative multi-player game-based optimization framework and an algorithm are presented to coordinate vehicles and achieve minimum values for the global pay-off conditions. Fuel consumption, passenger comfort, and travel time within the merging control zone were used as the pay-off conditions. After analyzing the characteristics of the merging control zone and selecting the appropriate control decision duration, multi-player games were decomposed into multiple two-player games. An optimal merging strategy was, thereby, derived from a pay-off matrix, and minimum payoffs were predicted for a number of different potential strategies. The optimal trajectory corresponding to the predicted minimum payoffs was then utilized as the control law to coordinate the vehicles merging. The proposed control scheme derives an optimal merging sequence and an optimal trajectory for each vehicle. The effectiveness of the proposed model is validated through simulation. Finally, the proposed controller is compared with two alternative methods to demonstrate its potential to reduce fuel consumption and travel time and to improve passenger comfort and traffic efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal Control Strategy With Efficiency and Reliability Improvement for Offshore DC Microgrids

Offshore microgrids, due to their remote location and lack of external energy support, face significant challenges in wide-range load operation and maintenance. Consequently, efficiency and reliability are critical concerns for converters in offshore dc microgrids. This article presents an optimal control strategy aimed at enhancing both efficiency and reliability. A normalized nonlinear relationship between power loss and thermal stress of a paralleled converter is first established. Based on this, a dual-objective optimization function with an active weight function as well as a system overall performance index is established. The active weight function dynamically adjusts the control priority based on converter efficiency and switching device thermal stress. Then, the optimal power-sharing strategy is derived by the Lagrange multiplier method with the proposed optimal function. Additionally, to accommodate a wide load range, an optimal selection strategy for operating converter combinations is proposed, requiring only low-bandwidth communication. Experiment verification is given to validate the effectiveness of the proposed control strategy. The experiment results demonstrate that the proposed control strategy can improve the overall performance of offshore microgrids by optimizing efficiency and reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Uncertainty propagation and sensitivity analysis for constrained optimization of nuclear waste vitrification

Abstract The vitrification of high‐level waste (HLW) by heating a mixture of glass‐forming chemicals (GFCs) with the waste can be improved using a constrained optimization problem. This study explores how different uncertainty propagation (UP) methods implemented with the optimization process can affect the glass formulation of nuclear waste glasses. UP is the effort of propagating uncertain inputs through a system to understand and quantify output distributions. Uncertainty intervals are crafted from output distributions to inform the optimization algorithm. UP is often implemented with Monte Carlo (MC) sampling for large nonlinear systems, which can be difficult to implement within a constrained optimization algorithm that requires derivative information. Other UP methods often used for optimization under uncertainty (OUU) can be designed to work within an established constrained optimization framework. Methods of UP are evaluated in this study including iterative sampling approaches, first‐order approximations, and surrogate modeling with machine learning (ML). A method of dimensional reduction based on global sensitivity analysis is introduced to support the UP methods for the large dimensionality of the problem. Analytical UP methods able to achieve similar optimums 10 times faster than the baseline MC approach, and produce 93.9% similar output distributions are reported.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimization of a Cyclone Using Multiphase Flow Computational Fluid Dynamics

The U.S. Department of Energy National Energy Technology Laboratory's (NETL) 50 kW th chemical looping reactor (CLR) has an underperforming cyclone, which was designed using empirical correlations. To improve the performance of this cyclone using computational fluid dynamics (CFD)-based modeling simulations, four critical design parameters including the vortex tube radius and length, barrel radius, and the inlet width and height were optimized. Here, NETL's open source multiphase flow with interphase exchange (MFiX) CFD code has been used to model a series of cyclones by systematically varying the geometric design parameters. To perform the optimization process, the surrogate modeling and sensitivity analysis followed by the optimization capability in nodeworks was used. The basic methodology for the process is to employ a statistical design of experiments (DOE) method to generate sampling simulations that fill the design space. Corresponding CFD models are then created, executed, and postprocessed. A response surface is created to characterize the relationship between input parameters and the quantities of interest (QoI). Finally, the CFD-surrogate is used by an optimization method to find the optimal design condition based on the objective and constraints prescribed. The resulting optimal cyclone has a larger diameter and longer vortex tube, a larger diameter barrel, and a taller and narrower solids inlet. The improved design has a predicted pressure drop 11 times lower than the original design while reducing the mass loss by a factor of 2.3.

42 ENGINEERING↗

Stepwise multi-criteria optimization for robotic radiosurgery

Achieving good conformality and a steep dose gradient around the target volume remains a key aspect of radiosurgery. Clearly, this involves a trade-off between target coverage, conformality of the dose distribution, and sparing of critical structures. Yet, image guidance and robotic beam placement have extended highly conformal dose delivery to extracranial and moving targets. Therefore, the multi-criteria nature of the optimization problem becomes even more apparent, as multiple conflicting clinical goals need to be considered coordinate to obtain an optimal treatment plan. Typically, planning for robotic radiosurgery is based on constrained optimization, namely linear programming. An extension of that approach is presented, such that each of the clinical goals can be addressed separately and in any sequential order. For a set of common clinical goals the mapping to a mathematical objective and a corresponding constraint is defined. The trade-off among the clinical goals is explored by modifying the constraints and optimizing a simple objective, while retaining feasibility of the solution. Moreover, it becomes immediately obvious whether a desired goal can be achieved and where a trade-off is possible. No importance factors or predefined prioritizations of clinical goals are necessary. The presented framework forms the basis for interactive and automated planning procedures. It is demonstrated for a sample case that the linear programming formulation is suitable to search for a clinically optimal treatment, and that the optimization steps can be performed quickly to establish that a Pareto-efficient solution has been found. Furthermore, it is demonstrated how the stepwise approach is preferable compared to modifying importance factors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimization of a dual-energy contrast-enhanced technique for a photon-counting digital breast tomosynthesis system: I. A theoretical model

Purpose: Dual-energy (DE) iodine contrast-enhanced x-ray imaging of the breast has been shown to identify cancers that would otherwise be mammographically occult. In this article, theoretical modeling was performed to obtain optimally enhanced iodine images for a photon-counting digital breast tomosynthesis (DBT) system using a DE acquisition technique. Methods: In the system examined, the breast is scanned with a multislit prepatient collimator aligned with a multidetector camera. Each detector collects a projection image at a unique angle during the scan. Low-energy (LE) and high-energy (HE) projection images are acquired simultaneously in a single scan by covering alternate collimator slits with Sn and Cu filters, respectively. Sn filters ranging from 0.08 to 0.22 mm thickness and Cu filters from 0.11 to 0.27 mm thickness were investigated. A tube voltage of 49 kV was selected. Tomographic images, hereafter referred to as DBT images, were reconstructed using a shift-and-add algorithm. Iodine-enhanced DBT images were acquired by performing a weighted logarithmic subtraction of the HE and LE DBT images. The DE technique was evaluated for 20-80 mm thick breasts. Weighting factors, w{sub t}, that optimally cancel breast tissue were computed. Signal-difference-to-noise ratios (SDNRs) between iodine-enhanced and nonenhanced breast tissue normalized to the square root of the mean glandular dose (MGD) were computed as a function of the fraction of the MGD allocated to the HE images. Peak SDNR/{radical}(MGD) and optimal dose allocations were identified. SDNR/{radical}(MGD) and dose allocations were computed for several practical feasible system configurations (i.e., determined by the number of collimator slits covered by Sn and Cu). A practical system configuration and Sn-Cu filter pair that accounts for the trade-off between SDNR, tube-output, and MGD were selected. Results: w{sub t} depends on the Sn-Cu filter combination used, as well as on the breast thickness; to optimally cancel 0% with 50% glandular breast tissue, w{sub t} values were found to range from 0.46 to 0.72 for all breast thicknesses and Sn-Cu filter pairs studied. The optimal w{sub t} values needed to cancel all possible breast tissue glandularites vary by less than 1% for 20 mm thick breasts and 18% for 80 mm breasts. The system configuration where one collimator slit covered by Sn is alternated with two collimator slits covered by Cu delivers SDNR/{radical}(MGD) nearest to the peak value. A reasonable compromise is a 0.16 mm Sn-0.23 mm Cu filter pair, resulting in SDNR values between 1.64 and 0.61 and MGD between 0.70 and 0.53 mGy for 20-80 mm thick breasts at the maximum tube current. Conclusions: A DE acquisition technique for a photon-counting DBT imaging system has been developed and optimized.

60 APPLIED LIFE SCIENCES↗

Proton beam scattering system optimization for clinical and research applications

Purpose: To develop and test a method for optimizing and constructing a dual scattering system in passively scattered proton therapy. Methods: A beam optics optimization algorithm was developed to optimize the thickness of the first scatterer (S1) and the profile (of both the high-Z material and Lexan) of the second scatterer (S2) to deliver a proton beam matching a given set of parameters, including field diameter, fluence, flatness, and symmetry. A new manufacturing process was also tested that allows the contoured second scattering foil to be created much more economically and quickly using Cerrobend casting. Two application-specific scattering systems were developed and tested using both experimental and Monte Carlo techniques to validate the optimization process described. Results: A scattering system was optimized and constructed to deliver large uniform irradiations of radiobiology samples at low dose rates. This system was successfully built and tested using film and ionization chambers. The system delivered a uniform radiation field of 50 cm diameter (to a dose of {+-}7% of the central axis) while the depth dose profile could be tuned to match the specifications of the particular investigator using modulator wheels and range shifters. A second scattering system for intermediate field size (4 cm < diameter < 10 cm) stereotactic radiosurgery and radiation therapy (SRS and SRT) treatments was also developed and tested using GEANT4. This system improved beam efficiency by over 70% compared with existing scattering systems while maintaining field flatness and depth dose profile. In both cases the proton range uniformity across the radiation field was maintained, further indicating the accuracy of the energy loss formalism in the optimization algorithm. Conclusions: The methods described allow for rapid prototyping of scattering foils to meet the demands of both research and clinical beam delivery applications in proton therapy.

60 APPLIED LIFE SCIENCES↗

Adaptation of the CVT algorithm for catheter optimization in high dose rate brachytherapy

Purpose: An innovative, simple, and fast method to optimize the number and position of catheters is presented for prostate and breast high dose rate (HDR) brachytherapy, both for arbitrary templates or template-free implants (such as robotic templates).Methods: Eight clinical cases were chosen randomly from a bank of patients, previously treated in our clinic to test our method. The 2D Centroidal Voronoi Tessellations (CVT) algorithm was adapted to distribute catheters uniformly in space, within the maximum external contour of the planning target volume. The catheters optimization procedure includes the inverse planning simulated annealing algorithm (IPSA). Complete treatment plans can then be generated from the algorithm for different number of catheters. The best plan is chosen from different dosimetry criteria and will automatically provide the number of catheters and their positions. After the CVT algorithm parameters were optimized for speed and dosimetric results, it was validated against prostate clinical cases, using clinically relevant dose parameters. The robustness to implantation error was also evaluated. Finally, the efficiency of the method was tested in breast interstitial HDR brachytherapy cases.Results: The effect of the number and locations of the catheters on prostate cancer patients was studied. Treatment plans with a better or equivalent dose distributions could be obtained with fewer catheters. A better or equal prostate V100 was obtained down to 12 catheters. Plans with nine or less catheters would not be clinically acceptable in terms of prostate V100 and D90. Implantation errors up to 3 mm were acceptable since no statistical difference was found when compared to 0 mm error (p > 0.05). No significant difference in dosimetric indices was observed for the different combination of parameters within the CVT algorithm. A linear relation was found between the number of random points and the optimization time of the CVT algorithm. Because the computation time decrease with the number of points and that no effects were observed on the dosimetric indices when varying the number of sampling points and the number of iterations, they were respectively fixed to 2500 and to 100. The computation time to obtain ten complete treatments plans ranging from 9 to 18 catheters, with the corresponding dosimetric indices, was 90 s. However, 93% of the computation time is used by a research version of IPSA. For the breast, on average, the Radiation Therapy Oncology Group recommendations would be satisfied down to 12 catheters. Plans with nine or less catheters would not be clinically acceptable in terms of V100, dose homogeneity index, and D90.Conclusions: The authors have devised a simple, fast and efficient method to optimize the number and position of catheters in interstitial HDR brachytherapy. The method was shown to be robust for both prostate and breast HDR brachytherapy. More importantly, the computation time of the algorithm is acceptable for clinical use. Ultimately, this catheter optimization algorithm could be coupled with a 3D ultrasound system to allow real-time guidance and planning in HDR brachytherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

A DVH-guided IMRT optimization algorithm for automatic treatment planning and adaptive radiotherapy replanning

Purpose: To develop a novel algorithm that incorporates prior treatment knowledge into intensity modulated radiation therapy optimization to facilitate automatic treatment planning and adaptive radiotherapy (ART) replanning. Methods: The algorithm automatically creates a treatment plan guided by the DVH curves of a reference plan that contains information on the clinician-approved dose-volume trade-offs among different targets/organs and among different portions of a DVH curve for an organ. In ART, the reference plan is the initial plan for the same patient, while for automatic treatment planning the reference plan is selected from a library of clinically approved and delivered plans of previously treated patients with similar medical conditions and geometry. The proposed algorithm employs a voxel-based optimization model and navigates the large voxel-based Pareto surface. The voxel weights are iteratively adjusted to approach a plan that is similar to the reference plan in terms of the DVHs. If the reference plan is feasible but not Pareto optimal, the algorithm generates a Pareto optimal plan with the DVHs better than the reference ones. If the reference plan is too restricting for the new geometry, the algorithm generates a Pareto plan with DVHs close to the reference ones. In both cases, the new plans have similar DVH trade-offs as the reference plans. Results: The algorithm was tested using three patient cases and found to be able to automatically adjust the voxel-weighting factors in order to generate a Pareto plan with similar DVH trade-offs as the reference plan. The algorithm has also been implemented on a GPU for high efficiency. Conclusions: A novel prior-knowledge-based optimization algorithm has been developed that automatically adjust the voxel weights and generate a clinical optimal plan at high efficiency. It is found that the new algorithm can significantly improve the plan quality and planning efficiency in ART replanning and automatic treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-23: A Novel Two-Step Optimization Scheme for Tandem and Ovoid (T and O) HDR Brachytherapy Treatment for Locally Advanced Cervical Cancer

Purpose: To present a novel method allowing fast, true volumetric optimization of T and O HDR treatments and to quantify its benefits. Materials and Methods: 27 CT planning datasets and treatment plans from six consecutive cervical cancer patients treated with 4–5 intracavitary T and O insertions were used. Initial treatment plans were created with a goal of covering high risk (HR)-CTV with D90 > 90% and minimizing D2cc to rectum, bladder and sigmoid with manual optimization, approved and delivered. For the second step, each case was re-planned adding a new structure, created from the 100% prescription isodose line of the manually optimized plan to the existent physician delineated HR-CTV, rectum, bladder and sigmoid. New, more rigorous DVH constraints for the critical OARs were used for the optimization. D90 for the HR-CTV and D2cc for OARs were evaluated in both plans. Results: Two-step optimized plans had consistently smaller D2cc's for all three OARs while preserving good D90s for HR-CTV. On plans with “excellent” CTV coverage, average D90 of 96% (range 91–102), sigmoid D2cc was reduced on average by 37% (range 16–73), bladder by 28% (range 20–47) and rectum by 27% (range 15–45). Similar reductions were obtained on plans with “good” coverage, with an average D90 of 93% (range 90–99). For plans with inferior coverage, average D90 of 81%, an increase in coverage to 87% was achieved concurrently with D2cc reductions of 31%, 18% and 11% for sigmoid, bladder and rectum. Conclusions: A two-step DVH-based optimization can be added with minimal planning time increase, but with the potential of dramatic and systematic reductions of D2cc for OARs and in some cases with concurrent increases in target dose coverage. These single-fraction modifications would be magnified over the course of 4–5 intracavitary insertions and may have real clinical implications in terms of decreasing both acute and late toxicity.

60 APPLIED LIFE SCIENCES↗

SU-E-T-367: Optimization of DLG Using TG-119 Test Cases and a Weighted Mean Approach

Purpose: Optimization of the dosimetric leaf gap (DLG) is an important step in commissioning the Eclipse treatment planning system for sliding window intensity-modulated radiation therapy (SW-IMRT) and RapidArc. Often the values needed for optimal dose delivery differ markedly from those measured at commissioning. We present a method to optimize this value using the AAPM TG-119 test cases. Methods: For SW-IMRT and RapidArc, TG-119 based test plans were created using a water-equivalent phantom. Dose distributions measured on film and ion chamber (IC) readings taken in low-gradient regions within the targets were analyzed separately. Since DLG is a single value per energy, SW-IMRT and RapidArc must be considered simultaneously. Plans were recalculated using a linear sweep from 0.02cm (the minimum DLG) to 0.3 cm. The calculated point doses were compared to the measured doses for each plan, and based on these comparisons an optimal DLG value was computed for each plan. TG-119 cases are designed to push the system in various ways, thus, a weighted mean of the DLG was computed where the relative importance of each type of plan was given a score from 0.0 to 1.0. Finally, SW-IMRT and RapidArc are assigned an overall weight based on clinical utilization. Our routine patient-QA (PQA) process was performed as independent validation. Results: For a Varian TrueBeam, the optimized DLG varied with σ = 0.044cm for SW-IMRT and σ = 0.035cm for RapidArc. The difference between the weighted mean SW-IMRT and RapidArc value was 0.038cm. We predicted utilization of 25% SW-IMRT and 75% RapidArc. The resulting DLG was ~1mm different than that found by commissioning and produced an average error of <1% for SW-IMRT and RapidArc PQA test cases separately. Conclusion: The weighted mean method presented is a useful tool for determining an optimal DLG value for commissioning Eclipse.

60 APPLIED LIFE SCIENCES↗