Search NASA⌕ Search

SEARCH · Search NASA

Results for “Grid Connection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Springboard Engineering's Smart Grid Controller for Non-Smart Household Electricity-Consuming Appliances (Final Technical Report)

The Smart Grid opens the door to the development of many companion technologies which will in turn enable the development of a variety of devices for household electricity-consuming appliances that can communicate with it; especially, many major appliance manufacturers (such as Whirlpool and General Electric) have made public commitments to design their appliances to be Smart Grid-compatible over the next several years. Yet during that same time period, customers will purchase many millions of long-lasting appliances which are not compatible with the Smart Grid. This research project's purpose is to bring significant Smart Grid compatibility to previously-installed appliances that were not specifically designed for any Smart Grid communications, in a way that is both economical and attractive for users who want to share in the energy cost savings and reduction of peak power demand opportunities provided by the evolving Smart Grid infrastructure. The focus of this effort is to identify and research smart control solutions which take advantage of the effective strategies of demand-response (DR) communications from utilities [including time-of-day (TOD) and peak-demand pricing options] and function apart from any need for operational changes to be designed into the non-smart appliances. Our Phase I concepts promote technological advancements for enabling devices that shift the available-use time of millions of different appliances which otherwise have no Smart Grid capability. We researched low-cost microcontroller-based ways of creating devices with the ability to: (1) maintain an accurate time and day (with no need for battery backup throughout a power outage); (2) perform two-way wired and wireless communications directly with the utility company's demand management signals, to identify both low-cost time periods as well as critical-reduction periods when the cost of energy use would otherwise be much higher; (3) measure the power usage of the connected non-smart appliance; and (4) remove power for a period of time from the appliance (such as a dehumidifier, portable heater, or pool pump) in response to both time-pricing schedule and critical peak-load information from the utility, or inform the user of a batch-type appliance (such as a clothes dryer or dishwasher) regarding the current cost associated with using the appliance. The new products that could be developed as a result of this research into new consumer-centric features and characteristics includes smart wall outlets, smart outlet power-monitoring adapters, smart load switches and smart remote electric rate indicators associated with the non-smart appliances. Our Phase I goal of determining the feasibility of the above technologies was successful. The objectives were also met of developing concepts for a family of microprocessor-based control/indicator devices that can provide the above capabilities while connected in series between an appliance and its electrical power source and/or while indicating cost-of-use status to the appliance user.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Service Oriented Architecture for Exploring High Performance Distributed Power Models

Power grids are increasingly incorporating high quality, high throughput sensor devices inside power distribution networks. These devices are driving an unprecedented increase in the volume and rate of available information. The real-time requirements for handling this data are beyond the capacity of conventional power models running in central utilities. Hence, we are exploring distributed power models deployed at the regional scale. The connection of these models for a larger geographic region is supported by a distributed system architecture. This architecture is built in a service oriented style, whereby distributed power models running on high performance clusters are exposed as services. Each service is semantically annotated and therefore can be discovered through a service catalog and composed into workflows. The overall architecture has been implemented as an integrated workflow environment useful for power researchers to explore newly developed distributed power models.

Service oriented architecture, high performance co↗

An Internal ALD-Based High Voltage Divider and Signal Circuit for MCP-based Photodetectors

We describe a pin-less design for the high voltage (HV) resistive divider of the all-glass LAPPD (TM) 8 in,square thin photodetector module. The divider, which distributes high voltage applied to the photocathode to the two micro-channel plates (MCPs) that constitute the amplification stage, is comprised of the two MCPs and three glass mechanical spacers, each of which is coated with a resistive layer using atomic layer deposition (ALD). The three glass grid spacers and the two MCPs form a continuous resistive path between cathode and anode, with the voltages across the MCPs and the spacers determined by the resistance of each. High voltage is applied on an external tab on the top glass window that connects to the photocathode through the metal seal. The DC ground is supplied by microstrips on the bottom glass plate that form the high-bandwidth anode. The microstrips exit the package through the glass-frit seal of the anode base-plate and the package sidewall. The divider is thus completely internal, with no HV pins penetrating the low-profile flat glass package. Measurements of the performance of the divider are presented for the 8 in.-square MCP and spacer package in a custom test fixture and for an assembled externally pumped LAPPD (TM) prototype with an aluminum photocathode. (C) 2015 Elsevier B.V. All rights reserved.

Adams, Bernhard W.↗

Setting up of a low temperature in-situ ion implantation and channeling facility at Kalpakkam

A simple low temperature ion implantation and ion channeling facility has been set up. Low temperatures upto 70 K has been obtained on a goniometer sample holder by connecting to a continuous flow Helium cryostat with a copper braid. Charge integration is carried out with a transmission Faraday cup with 10 mm diameter aperture and four Faraday cups for performing ion implantation and an electron suppressed 1.5 mm aperture with a TEM grid of 60% beam transmission for ion beam analysis. Typical low temperature ion implantation and channeling experiments have been carried out. Stabilization at intermediate temperatures by controlling the heater at the sample holder and improvement of the achievable lowest temperature by having liquid nitrogen cooled heat shield are in progress.

43 PARTICLE ACCELERATORS↗

Low-Frequency Stability Analysis of Inverter-Based Islanded Multiple-Bus AC Microgrids Based on Terminal Characteristics

For system planning of three-phase inverter-based islanded ac microgrids, the low frequency instability issue caused by interactions of inverter droop controllers is a major concern. When internal control information of procured commercial inverters is unknown, impedance-based small-signal stability criteria facilitate prediction of resonances in medium and high frequency ranges, but they usually assume the grid fundamental frequency as constant and thus they are incapable of analyzing the low-frequency oscillation of the fundamental frequency in islanded microgrids. Aiming at solving this issue, this paper proposes two stability analysis methods based on terminal characteristics of inverters and passive connection network including the dynamics of the fundamental frequency for analysis of low-frequency stability in islanded multiple-bus microgrids. Based on the Component Connection Method (CCM) to systematically separate inverters from the passive connection network, a general approach is developed to model the microgrid as a multiple-input-multiple-output (MIMO) negative feedback system in the common system d-q reference frame. By applying the generalized Nyquist stability criterion (GNC) to the return-ratio and return-difference matrices of the MIMO system model, the low-frequency stability related to the fundamental frequency can be analyzed using the measured terminal characteristics of inverters. Finally, analysis and simulation of a 37-bus microgrid verify the effectiveness of the proposed stability analysis methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Built-in Thermionic Electron Source for an SRF Linacs

The design of a thermionic electron source connected directly to a superconducting cavity, the key part of an SRF gun, is described. The results of beam dynamics optimization are presented which allow lack of beam current intercepting in the superconducting cavity. The electron source concept is presented including the cathode-grid assembly, thermal insulation of the cathode from the cavity, and the gun resonator design. The cavity thermal load caused by the gun is analyzed including the static heat load, black body radiation, backward electron heating, etc.

43 PARTICLE ACCELERATORS↗

A Unified Testing Platform to Mature Blockchain Applications for Grid Emulation Environments: Preprint

Blockchain technology is a relatively novel technology that can be used to develop more decentralized, autonomous and tamper-evident solutions. A feature that can aid Transactive Energy Systems to reach their goals by enabling individual actors to communicate and reach consensus with other participants in a more decentralized fashion. However, technical barriers to evaluate and adopt this type of technology within the electrical domain still exist. To facilitate this task, BLOSEM Unified Testing Platform (UTP), a DOE-sponsored, multi-lab effort intends to accelerate the development of solutions by offering a common set of reusable services that can be used to interconnect existent grid tools with blockchain services. UTP is intended to serve as development platform that can provide application engineers with the technical means to evaluate potential blockchain solutions, by enabling them to concentrate on the actual application functionalities while at the same time abstracting the connectivity and performance measurement tasks. The use of BLOSEM UTP is further demonstrated by implementing two potential use cases that are intended to validate both the feasibility of implementing these applications as blockchain-based solutions while also demonstrating the features provided by UTP.

blockchain↗

An Open Source Modeling Framework for Interdependent Energy-Transportation-Communication Infrastructure in Smart and Connected Communities

Infrastructure in future smart and connected communities is envisioned as an aggregate of public services, including energy, transportation, and communication systems, all intertwined with each other. The intrinsic interdependency among these systems may exert the underlying influence on both design and operation of the heterogeneous infrastructures. Yet, few prior studies have tapped into the interdependency among these systems in order to quantify their potential impacts during standard operation. In response to this, this paper proposes an open-source, flexible, integrated modeling framework suitable for designing coupled energy, transportation, and communication systems and for assessing the impact of their interdependencies. First, a novel multi-level, multi-layer, multi-agent approach is proposed to enable flexible modeling of the interconnected systems. Then, for the framework's proof of concept, preliminary component and system-level models for different systems are designed and implemented using Modelica, an equation-based object-oriented modeling language. Finally, three case studies of gradually increasing complexity are presented (energy, energy + transportation, and energy + transportation + communication) to evaluate the interdependencies among the three systems. Quantitative analyses show that the deviation of the average velocity on the road can be 10.5% and the deviation of the power drawn from the grid can be 7% with or without considering the transportation and communication system at the peak commute time, indicating the presence of notable interdependencies. The proposed modeling framework also has the potential to be further extended for various modeling purposes and use cases, such as dynamic modeling and optimization, resilience analysis, and integrated decision making in future connected communities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling the Water Systems of the Western US to Support Climate‐Resilient Electricity System Planning

Abstract Electricity and water systems in the Western US (WUS) are closely connected, with hydropower comprising 20% of total annual WUS generation, and electricity related to water comprising about 7% of total WUS electricity use. Because of these interdependencies, the threat of climate change to WUS resources will likely have compounding electricity impacts on the Western Interconnect grid. This study describes a WUS‐wide water system model with a particular emphasis on estimating climate impacts on hydropower generation and water‐related electricity use, which can be linked with a grid expansion model to support climate‐resilient electricity planning. The water system model combines climatically‐driven physical hydrology and management of both water supply and demand allocation, and is applied to an ensemble of 15 climate scenarios out to 2050. Model results show decreasing streamflow in key basins of the WUS under most scenarios. Annual water‐related electricity use increases up to 4%, and by up to 6% during the summer months, driven by growing agricultural demands met increasingly through a shift toward energy‐intensive groundwater to replace declining surface water. Total annual hydropower generation changes by +5% to −20% by mid‐century but declines in most scenarios, with decreases in summer generation by up to nearly −30%. Water‐related electricity use increases tend to coincide with hydropower generation declines, annually and seasonally, demonstrating the importance of concurrently evaluating the climate signal on both water‐for‐energy and energy‐for‐water to inform planning for grid reliability and decarbonization goals.

13 HYDRO ENERGY↗

2022 Component Innovation Awardee: Windurance

Combining battery energy storage with distributed wind energy systems can increase production, ability to meet local electricity demands, interconnection capacity, and potential sales of surplus energy back to the grid, while reducing demand charges and the overall levelized cost of energy (LCOE). Energy storage options for distributed wind energy systems can vary widely in terms of power level and energy storage capacity, and their potential benefits depend on factors including wind resource, turbine design, connection requirements, use patterns, utility rates, and regulations. Windurance received a 2022 Competitiveness Improvement Project (CIP) funding award to add battery energy storage capabilities to the company's bidirectional DC converter. The energy storage component will complete a comprehensive portfolio of power conversion and control electronics that can be seamlessly integrated with distributed wind systems. The company received earlier CIP awards to fund prototype design and construction of wind turbine pitch actuators, inverters, and controllers.

CIP↗

Improved multiline HVDC circuit breakers with asymmetric conducting branches

Here, this paper proposes two improved multiline HVDC circuit breakers (DCBs) for HVDC grid applications, including type-1 improved multiline DCB and type-2 improved multiline DCB. The two improved DCBs draw on the core idea of extended H-bridge. m adjacent DC transmission lines share a single main breaker (MB) and surge arrester. Due to the extended H-bridge design, bidirectional current flow can be achieved by a unidirectional MB. An upper conducting branch and a lower conducting branch are connected to a DC line. The upper and lower conducting branches in the two improved multiline DCBs are asymmetric. The upper conducting branch of both two improved DCBs is formed by a load commutation switch (LCS) and an ultra-fast disconnector (UFD). The lower conducting branch of the type-1 improved scheme is composed of a diode and a UFD; and of the type-2 improved scheme is made up of diode stack. Compared with other DCBs, the proposed type-1 DCB and type-2 DCB are more cost effective. Among the five DCBs, the type-2 improved scheme requires the least number of individual switching actions. The effectiveness and feasibility of the proposed schemes are verified through simulation of a bipolar three-terminal HVDC grid in PSCAD/EMTDC.

42 ENGINEERING↗

Distributing Power Grid State Estimation on HPC Clusters A System Architecture Prototype

The future power grid is expected to further expand with highly distributed energy sources and smart loads. The increased size and complexity lead to increased burden on existing computational resources in energy control centers. Thus the need to perform real-time assessment on such systems entails efficient means to distribute centralized functions such as state estimation in the power system. In this paper, we present our early prototype of a system architecture that connects distributed state estimators individually running parallel programs to solve non-linear estimation procedure. The prototype consists of a middleware and data processing toolkits that allows data exchange in the distributed state estimation. We build a test case based on the IEEE 118 bus system and partition the state estimation of the whole system model to available HPC clusters. The measurement from the testbed demonstrates the low overhead of our solution.

Distributed architecture↗

Self-Supervised T-GCN for Detection of Disturbance and Propagation in Power Grid

Urban power systems increasingly rely on dense sensing to monitor grid reliability, yet disturbance labels are scarce and events are rare. We present a self-supervised spatio-temporal method that detects, localizes, and characterizes grid frequency disturbances across urban areas using only unlabeled data. Our approach trains a tiny Temporal Graph Convolutional Network (T-GCN) to forecast per-site frequency residuals (deviation from 60 Hz). The sensor graph is constructed directly from signals using pre-event Pearson correlation with a cross-correlation lag penalty without geocoding. At inference, node-level anomalies are the model's forecast errors; region-level alarms arise from connected components of high-score nodes. We estimate disturbance propagation by computing per-node arrival times (first persistent exceedance), then fit a planar or time-of-arrival model to obtain direction, speed, and an epicenter proxy. With only three real events collected at decisecond resolution across U.S. cities, we evaluate the T-GCN and report time-to-detect, footprint size, and propagation consistency. We further show that short-window embeddings from the T-GCN's hidden states enable few-shot event-vs-background recognition via a simple prototypical classifier. Despite minimal data and no labels, our system yields fast, spatially coherent detection and interpretable propagation maps, offering a practical, lightweight pathway to city-scale grid resilience analytics.

Niu, Haoran [ORNL] (ORCID:0000000155228297)↗

Topology-Aware Reinforcement Learning for Voltage Control: Centralized and Decentralized Strategies

Volt-VAR control (VVC) methods based on deep reinforcement learning (DRL) can effectively control distribution grid voltage and minimize power loss by implementing corrective and preventive control measures on the reactive power output of inverter-based distributed energy resources (DERs). However, model-free DRL-based VVC approaches usually cannot capture the important topological feature of the power system since they use a fully-connected network (FCN) to deliver the action. Therefore, this paper proposes a graph convolutional network (GCN)-based DRL approach that can employ the topological information of the network to take better control action for regulating the voltage. Our implementation allows for both centralized and decentralized configurations, utilizing a single agent and multiple agents respectively. Although the centralized GCN-based DRL approach has its advantages of minimizing voltage fluctuation and power loss, it is not suitable for large scale power systems due to its challenges in terms of scalability, computation speed and potential single points of failure. Therefore, these problems can be resolved using the decentralized GCN-based DRL approach. Moreover, to ensure the safe operation of the model, our proposed approach incorporates an exponential barrier function while formulating the reward function for each agent. To validate performance of the proposed approaches, the proposed model is tested on modified IEEE test systems and the performances are measured in terms on voltage fluctuation reduction, minimization of power loss and computational speed. Finally, the results show that the proposed topology-aware approach outperforms the FCN-based DRL approach in terms of reducing voltage fluctuation and minimizing power loss of the network. Moreover, it is shown that the decentralized GCN-based DRL has faster computational speed than other approaches.

42 ENGINEERING↗

Department of Energy Project DE-SC0012198: Probing Electron-Molecule Scattering with HHG: Theory and Experiment (Final Report)

The study of the motion of atoms in molecules is important to understanding many areas of physical and life sciences. Such motion occurs on many different times scales, with electronic motion occurring on a sub-femtosecond time scale, and simple vibrational motion in tens to hundreds of femtoseconds. One way to follow such processes in real time is by the use of shortpulsed lasers, and in particular by studying time-resolved photoionization and the related process of high-harmonic generation (HHG). Thus there has been much effort to develop the tools necessary to probe molecular systems using short pulse lasers and understanding the sensitivity of the different possible probes to the time dependent geometric structure as well as the electronic structure of molecules. Our research has particularly focused on the connection between high-field processes and the more traditional weak field photoionization processes. Strong field and weak field processes can be connected through models that involve the same matrix elements. We have demonstrated in our study of HHG from SF 6 that the spectrum is sensitive to the interplay between the angular dependence of the ionization step and recombination step. In our study of rescattering spectroscopy, we have shown that with a combination of experiment and theory, we can use this high-field spectroscopy to determine molecular structure in molecules such as C 2 H 4 . We have also developed new computational tools based on overset grids to enable studies on larger molecular systems which use much more robust numerical approaches so that the resulting code can be a tool that non-specialists can use to study related systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Penetration Photovoltaic Planning Methodologies

The main objective of this report is to provide an overview of select U.S. utility methodologies for performing high-penetration photovoltaic (HPPV) system planning and impact studies. This report covers the Federal Energy Regulatory Commission's orders related to photovoltaic (PV) power system interconnection, particularly the interconnection processes for the Large Generation Interconnection Procedures and Small Generation Interconnection Procedures. In addition, it includes U.S. state interconnection standards and procedures. The procedures used by these regulatory bodies consider the impacts of HPPV power plants on the networks. Technical interconnection requirements for HPPV voltage regulation include aspects of power monitoring, grounding, synchronization, connection to the overall distribution system, back-feeds, disconnecting means, abnormal operating conditions, and power quality. This report provides a summary of mitigation strategies to minimize the impact of HPPV. Recommendations and revisions to the standards may take place as the penetration level of renewables on the grid increases and new technologies develop in future years.

14 SOLAR ENERGY↗

High Altitude Electromagnetic Pulse Testing of Photovoltaic Modules

This report details the test setup, process, and results for radiated susceptibility testing of multicrystalline silicon photovoltaic (PV) modules as part of the EMP-Resilient Electric Grid Grand Challenge Laboratory Directed Research and Development (LDRD) project at Sandia National Laboratories. Testing was conducted over October 10-17, 2019, where 8 photovoltaic modules were exposed to E1 transient pulses with peak field levels up to 100 kV/m. Modules were terminated in a resistive load representing connected components. State of health testing conducted via I-V curve tracing of the photovoltaic modules showed no observable loss of device function due to large electric field transients. Differential mode currents were measured on the order of 10's of amps for up to a microsecond following the radiated field pulse. Common mode currents took the form of a damped sinusoid with a maximum peak of 10's to 100's of amps with a resonance near 60 MHz.

14 SOLAR ENERGY↗