Search NASA⌕ Search

SEARCH · Search NASA

Results for “Phase 1 Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

Assessment of NDE Methods on Inspection of HDPE Butt Fusion Piping Joints for Lack of Fusion with Validation from Mechanical Testing

Studies at the Pacific Northwest National Laboratory (PNNL) in Richland, Washington, are being conducted to evaluate nondestructive examinations (NDE) coupled with mechanical testing of butt fusion joints in high-density polyethylene (HDPE) pipe for assessing lack of fusion. The work provides information to the U.S. Nuclear Regulatory Commission (NRC) on the effectiveness of volumetric inspection techniques of HDPE butt fusion joints in Section III, Division 1, Class 3, buried piping systems in nuclear power plants. This paper describes results from preliminary assessments using ultrasonic and microwave nondestructive techniques and mechanical testing with the high-speed tensile impact test and the side-bend test for determining joint integrity. A series of butt joints were fabricated in 3408, 12-in. IPS DR-11 HDPE material by varying the fusion parameters to create good joints and joints containing a range of lack-of-fusion conditions. Six of these butt joints were volumetrically examined with time-of-flight diffraction (TOFD), phased-array (PA) ultrasound, and the Evisive microwave system. The outer-diameter weld beads were removed for the microwave inspection. In two of the four pipes, both the outer and inner weld beads were removed and the pipe joints re-evaluated. The pipes were sectioned and the joints destructively evaluated with the side-bend test by cutting portions of the fusion joint into slices that were planed and bent. The last step in this limited study will be to correlate the fusion parameters, nondestructive, and destructive evaluation results to validate the effectiveness of what each NDE technology detects and what each does not detect. The results of the correlation will be used in identifying any future work that is needed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Fabrication experience of the pre-production PIP-II SSR2 cavities at Fermilab

The Proton Improvement Plan-II (PIP-II, [1]) linac will include 35 Single Spoke Resonators type 2 (SSR2). A total of eight pre-production SSR2 jacketed cavities will be procured and five installed in the first pre-production cryomodule. The mechanical design of the jacketed cavity has been finalized and it will be presented in this paper along with fabrication and processing experience. The importance of interfaces, quality controls and procurement aspects in the design phase will be remarked as well as lessons learned during the fabrication process. Furthermore, development studies will be presented together with other design validation tests.

43 PARTICLE ACCELERATORS↗

Grout Isolation and Stabilization of Structures and Materials within Nuclear Facilities at the U.S. Department of Energy, Hanford Site, Summary - 12309

Per regulatory agreement and facility closure design, U.S. Department of Energy Hanford Site nuclear fuel cycle structures and materials require in situ isolation in perpetuity and/or interim physicochemical stabilization as a part of final disposal or interim waste removal, respectively. To this end, grout materials are being used to encase facilities structures or are being incorporated within structures containing hazardous and radioactive contaminants. Facilities where grout materials have been recently used for isolation and stabilization include: (1) spent fuel separations, (2) uranium trioxide calcining, (3) reactor fuel storage basin, (4) reactor fuel cooling basin transport rail tanker cars and casks, (5) cold vacuum drying and reactor fuel load-out, and (6) plutonium fuel metal finishing. Grout components primarily include: (1) portland cement, (2) fly ash, (3) aggregate, and (4) chemical admixtures. Mix designs for these typically include aggregate and non aggregate slurries and bulk powders. Placement equipment includes: (1) concrete piston line pump or boom pump truck for grout slurry, (2) progressive cavity and shearing vortex pump systems, and (3) extendable boom fork lift for bulk powder dry grout mix. Grout slurries placed within the interior of facilities were typically conveyed utilizing large diameter slick line and the equivalent diameter flexible high pressure concrete conveyance hose. Other facilities requirements dictated use of much smaller diameter flexible grout conveyance hose. Placement required direct operator location within facilities structures in most cases, whereas due to radiological dose concerns, placement has also been completed remotely with significant standoff distances. Grout performance during placement and subsequent to placement often required unique design. For example, grout placed in fuel basin structures to serve as interim stabilization materials required sufficient bearing i.e., unconfined compressive strength, to sustain heavy equipment yet, low breakout force to permit efficient removal by track hoe bucket or equivalent construction equipment. Further, flow of slurries through small orifice geometries of moderate head pressures was another typical design requirement. Phase separation of less than 1 percent was a typical design requirement for slurries. On the order of 30,000 cubic meters of cementitious grout have recently been placed in the above noted U.S. Department of Energy Hanford Site facilities or structures. Each has presented a unique challenge in mix design, equipment, grout injection or placement, and ultimate facility or structure performance. Unconfined compressive and shear strength, flow, density, mass attenuation coefficient, phase separation, air content, wash-out, parameters and others, unique to each facility or structure, dictate the grout mix design for each. Each mix design was tested under laboratory and scaled field conditions as a precursor to field deployment. Further, after injection or placement of each grout formulation, the material was field inspected either by standard laboratory testing protocols, direct physical evaluation, or both. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TAILORING INORGANIC SORBENTS FOR SRS STRONTIUM AND ACTINIDE SEPARATIONS: MODIFIED MONOSODIUM TITANATE PHASE III FINAL REPORT

This document provides a final report of Phase III testing activities for the development of modified monosodium titanate (mMST), which exhibits improved strontium and actinide removal characteristics compared to the baseline MST material. The activities included characterization of the crystalline phases present at varying temperatures, solids settling characteristics, quantification of the peroxide content; evaluation of the post-synthesis gas release under different conditions; the extent of desorption of {sup 85}Sr, Np, and Pu under washing conditions; and the effects of age and radiation on the performance of the mMST. Key findings and conclusions include the following. The peroxide content of several mMST samples was determined using iodometric titration. The peroxide content was found to decrease with age or upon extended exposure to elevated temperature. A loss of peroxide was also measured after exposure of the material to an alkaline salt solution similar in composition to the simulated waste solution. To determine if the loss of peroxide with age affects the performance of the material, Sr and actinide removal tests were conducted with samples of varying age. The oldest sample (4 years and 8 months) did show lower Sr and Pu removal performance. When compared to the youngest sample tested (1 month), the oldest sample retained only 15% of the DF for Pu. Previous testing with this sample indicated no decrease in Pu removal performance up to an age of 30 months. No loss in Np removal performance was observed for any of the aged samples, and no uptake of uranium occurred at the typical sorbent loading of 0.2 g/L. Additional testing with a uranium only simulant and higher mMST loading (3.0 g/L) indicated a 10% increase of uranium uptake for a sample aged 3 years and 8 months when compared to the results of the same sample measured at an age of 1 year and 5 months. Performance testing with both baseline-MST and mMST that had been irradiated in a gamma source to a total dose of 3.95 x 10{sup 6} R, indicated little to no affect on the performance of the material to remove Sr and actinides. Previous testing established that mMST releases oxygen gas during the synthesis, and continues to off-gas during storage post synthesis. The post-synthesis gas release rate was measured under several conditions, including varying the pH of the wash water and at elevated temperature (49 C, typical of bounding summertime storage without air conditioning). Results indicated that a high pH (basic) wash reduced the initial gas release rate, but after 2 days the release rates from all different pH washed samples were not statistically different. The gas release rate at 49 C, a temperature at which the material may be exposed to during shipping and storage, was consistently about 2.5 times higher than the rate at room temperature. All gas release results indicated that vented containers would be necessary for shipping and storage of large quantities of material. Suspension of sorbate-loaded solids into diluted solutions representing intermediate and final stages of washing for 24-hours revealed no evidence of desorption of Sr, Pu or Np from the mMST solids. Based on the results of the Phase III testing as well as that from earlier studies (Phases I and II), SRNL researchers recommend adopting the use of the mMST material for the removal of strontium and actinides from the SRS HLW supernatant liquids in the Actinide Removal Process and Salt Waste Processing Facility. Given the decrease in Sr and Pu removal performance for the mMST having an age of 4 years and 8 months, we recommend that mMST be used within 30 months of production. Furthermore we recommend that DOE provide funding to conduct pilot-scale testing of the mixing and settling characteristics of the mMST and impact, if any, on the generation of hydrogen during processing in the Defense Waste Processing Facility (DWPF).

08 HYDROGEN↗

Python Materials Genomics (pymatgen): A robust, open-source python library for materials analysis

We present the Python Materials Genomics (pymatgen) library, a robust, open-source Python library for materials analysis. A key enabler in high-throughput computational materials science efforts is a robust set of software tools to perform initial setup for the calculations (e.g., generation of structures and necessary input files) and post-calculation analysis to derive useful material properties from raw calculated data. The pymatgen library aims to meet these needs by (1) defining core Python objects for materials data representation, (2) providing a well-tested set of structure and thermodynamic analyses relevant to many applications, and (3) establishing an open platform for researchers to collaboratively develop sophisticated analyses of materials data obtained both from first principles calculations and experiments. The pymatgen library also provides convenient tools to obtain useful materials data via the Materials Project's REpresentational State Transfer (REST) Application Programming Interface (API). As an example, using pymatgen's interface to the Materials Project's RESTful API and phasediagram package, we demonstrate how the phase and electrochemical stability of a recently synthesized material, Li 4 SnS 4 , can be analyzed using a minimum of computing resources. Here, we find that Li 4 SnS 4 is a stable phase in the Li-Sn-S phase diagram (consistent with the fact that it can be synthesized), but the narrow range of lithium chemical potentials for which it is predicted to be stable would suggest that it is not intrinsically stable against typical electrodes used in lithium-ion batteries.

36 MATERIALS SCIENCE↗

Neutron energy spectrum influence on irradiation hardening and microstructural development of tungsten

We performed a neutron irradiation to single crystal pure tungsten in the mixed spectrum High Flux Isotope Reactor (HFIR). In order to investigate the influences of neutron energy spectrum, the microstructure and irradiation hardening were compared with previous data obtained from the irradiation campaigns in the mixed spectrum Japan Material Testing Reactor (JMTR) and the sodium-cooled fast reactor Joyo. The irradiation temperatures were in the range of ~90–~800 °C and fast neutron fluences were 0.02–9.00 × 10 25 n/m 2 (E > 0.1 MeV). Post irradiation evaluation included Vickers hardness measurements and transmission electron microscopy. Moreover, the hardness and microstructure changes exhibited a clear dependence on the neutron energy spectrum. The hardness appeared to increase with increasing thermal neutron flux when fast fluence exceeds 1 × 10 25 n/m 2 (E > 0.1 MeV). Finally, irradiation induced precipitates considered to be χ- and σ-phases were observed in samples irradiated to >1 × 10 25 n/m 2 (E > 0.1 MeV), which were pronounced at high dose and due to the very high thermal neutron flux of HFIR. Although the irradiation hardening mainly caused by defects clusters in a low dose regime, the transmutation-induced precipitation appeared to impose additional significant hardening of the tungsten.

36 MATERIALS SCIENCE↗

Covariation of Slab Tracers, Volatiles, and Oxidation During Subduction Initiation

Abstract Subduction‐related lavas have higher Fe 3+ /∑Fe than midocean ridge basalts (MORB). Hypotheses for this offset include imprint from subducting slabs and differentiation in thickened crust. These ideas are readily tested through examination of the time‐dependent evolution of slab‐derived signatures, thickening crust of the overriding plate, and evolving redox during subduction initiation. Here, we present Fe 3+ /ΣFe and volatile element abundances of volcanic glasses recovered from International Ocean Discovery Program (IODP) Expedition 352 to the Izu‐Bonin‐Mariana (IBM) forearc. The samples include forearc basalts (FAB) that are stratigraphically overlain by low‐ and high‐silica boninite lavas. The FAB glasses have 0.18–0.85 wt% H 2 O, 75–233 ppm CO 2 , S contents controlled by saturation with a sulfide phase (602–1,386 ppm), Ba/La from 3.9‐10, and Fe 3+ /ΣFe ratios from 0.136 to 0.177. These compositions are similar to MORB and suggest that decompression melting of dry and reduced mantle dominates the earliest stages of subduction initiation. Low‐ and high‐silica boninite glasses have 1.51–3.19 wt% H 2 O, CO 2 below detection, S contents below those required for sulfide saturation (5–235 ppm), Ba/La from 11 to 29, and Fe 3+ /∑Fe from 0.181 to 0.225. The compositions are broadly similar to modern arc lavas in the IBM arc. These data demonstrate that the establishment of fluid‐fluxed melting of the mantle, which occurs in just 0.6–1.2 my after subduction initiation, is synchronous with the production of oxidized, mantle‐derived magmas. The coherence of high Fe 3+ /∑Fe and Ba/La ratios with high H 2 O contents in Expedition 352 glasses and the modern IBM arc rocks strongly links the production of oxidized arc magmas to signatures of slab dehydration.

Brounce, Maryjo↗

OBSERVATIONAL EVIDENCE FROM SDSS FOR A MERGER ORIGIN OF THE MILKY WAY'S THICK DISK

We test four competing models that aim to explain the nature of stars in spiral galaxies that are well away (>1 kpc) from the midplane, the so-called thick disk: the stars may have gotten there through orbital migration, through satellite mergers and accretion, or through heating of pre-existing thin disk stars. The eccentricity distribution of thick disk stars has recently been proposed as a diagnostic to differentiate between these mechanisms. Drawing on SDSS data release 7, we have assembled a sample of 31,535 G-dwarfs with six-dimensional phase-space information and metallicities and have derived the orbital eccentricities for them. Comparing the resulting eccentricity distributions, p(e|z), with these particular simulations, we find that: (1) the observed p(e|z) is inconsistent with that predicted by orbital migration only, as there are more observed stars of high and of very low eccentricity; (2) simulations in which the thick disk is made predominantly through heating a pre-existing thin disk are also inconsistent, as they predict more high-eccentricity stars than observed; (3) the observed p(e|z) fits well with a 'gas-rich merger' scenario, where most thick disk stars were born in situ. Further modeling could explore whether the data-simulation inconsistencies found here for the first three cases actually rule out the qualitative scenarios underlying these simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

One Step Hydrogen Generation Through Sorption Enhanced Reforming

One-step hydrogen generation, using Sorption Enhanced Reforming (SER) technology, is an innovative means of providing critical energy and environmental improvements to US manufacturing processes. The Gas Technology Institute (GTI) is developing a Compact Hydrogen Generator (CHG) process, based on SER technology, which successfully integrates previously independent process steps, achieves superior energy efficiency by lowering reaction temperatures, and provides pathways to doubling energy productivity with less environmental pollution. GTI’s prior CHG process development efforts have culminated in an operational pilot plant. During the initial pilot testing, GTI identified two operating risks- 1) catalyst coating with calcium aluminate compounds, 2) limited solids handling of the sorbent. Under this contract GTI evaluated alternative materials (one catalyst and two sorbents) to mitigate both risks. The alternate catalyst met performance targets and did not experience coating with calcium aluminate compounds of any kind. The alternate sorbent materials demonstrated viable operation, with one material enabling a three-fold increase in sorbent flow. The testing also demonstrated operation at 90% of its rated capacity. Lastly, a carbon dioxide co-production study was performed to assess the advantage of the solid phase separation of carbon dioxide- inherent in the CHG process. Approximately 70% lower capital cost is achievable compared to SMR-based hydrogen production with CO2 capture, as well as improved operating costs.

08 HYDROGEN↗

Novel, Low-Cost, Light-Weight High Efficiency (H*10 Capable) Neutron Detector-Dosimeter

The goal of this project was to design, develop and validate a novel, spectroscopy enabled H*(10) neutron dosimetry system based on the tensioned metastable fluid detector (TMFD) sensor technology. The project team consisted of staff from Oak Ridge National Laboratory (ORNL), Purdue University (PU) and Sagamore Adams Laboratories, LLC (SAL). PU-SAL staff were tasked with the design, development, construction and testing of the H*TMFD hardware and software, along with developing the control and data acquisition software for comparison of predictions from H*TMFD against a commonly accepted and widely used industry standard system; for this project, the Li-I detector coupled to bonner spheres (LiI-BSS) system manufactured by Ludlum, Inc. was utilized as the reference (“gold”) standard – similar in terms of neutron spectroscopy enablement to another industry recognized, albeit, significantly higher cost (est. $300K) system referred to as “ROSPEC” (from BTI, Inc., which was not available for this project). ORNL staff were tasked with providing field-relevant guidance, apparatus and facilities for acquiring data against calibrated neutron sources, and comparing results of H*TMFD against LiI-BSS system predictions in a series of blind-tests conducted at ORNL. Over the course of 12 months, the PU-SAL-ORNL staff successfully accomplished the proposed technical and administrative tasks, inclusive of engaging in outreach to potential users of this technology in the DOE-wide infrastructure. The proposed tasks were successfully accomplished in timely manner; the follow-up type tasks pertaining to SBIR type Phases 2-3 were discussed and are initiated, inclusive of filing for intellectual property (IP) disclosures and possible patent filings by PU’s Office of Technology Commercialization (OTC). Two H*TMFD system architectures (see Exhibits 1 & 2 in the report) were developed and constructed for hand-portability by health-physicists (HPs) – the HP-H*TMFD, and the H*TMFD system which consists of a side-by-side mounted array of 4 TMFDs of 3 different sizes in sensitive volume (including one with borated fluid) that now simultaneously enables neutron energy spectroscopy: single bin for < 0.1 MeV, and 152 energy bins in the 0.1-15.2 MeV range; H*(10) dosimetry from ~5 μRem/h towards 10 R/h ranges. Several experiments were conducted using neutron sources in various configurations (shielded and unshielded). In direct comparison against the LiI-BSS industry standard (acquiring data for 26h each source), the H*TMFD system (acquiring data for ~6h for each source) offered H*(10) dose predictions for the most part accurate to within +/-10% for dose rates in the 100-300 μRem/h range. The LiI-BSS was impractical to use under ultra-low (~10 μRem/h) dose rate space, as also another metering device used at ORNL (Ludlum 4241L non-spectroscopy enabled) for which the lower limit is set by the manufacturer at 100 μRem/h. The enablement for efficient use in timely manner at the 10 μRem/h levels is deemed to be a strong enabling factor for H*TMFD for use in the DOE-nuclear laboratory arena. In terms of weight, the HP-H*TMFD weighs under ~5-7 lb.; the H*TMFD system weighs ~35-lb. As such, it is ~1/4 the weight of an LiI-BSS system weighing ~120 lb (LiI detector with 6 bonner spheres) and, ~1/2 the weight of ROSPEC. As a result of this activity, two involved post-doctoral student staff have now transitioned their knowledge and experiences to DOE’s Pacific Northwest National Laboratory (PNNL). A PU graduate student has also benefited from this project work which formed a principal basis for his Ph.D. dissertation work (in progress).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Current-Activated Reactive Ultrafast Joining (CARUJ)

We have demonstrated Current Activated Reactive Ultrafast Joining (CARUJ) as a novel approach for rapid fabrication of similar and dissimilar materials, such as ceramic-ceramic and ceramic-metal joint assemblies. The CARUJ technology utilizes resistive heating of carbon-based materials to apply localized heat at, (through or around) joint zones at rates of 10 1 -10 2 ˚C/min, enabling joining at time scales considerably shorter (several minutes as opposed to hours) than conventional approaches for similar systems. Herein, we present our findings while evaluating the CARUJ concept. Three methods of heat application were evaluated: (i) using carbon joule heating elements to apply heat directly through the joint interface; (ii) using flexible joule heating elements to locally apply heat around the assembly interface; and (iii) non-contact heating of the joint assembly using inductive power. Schemes (ii) and (iii) proved to be the most effective in producing mechanically sound reliable joints. We demonstrated single-step fabrication of dense SiC-SiC joints with a Si- SiC interface using minimal pressure (1–2 MPa) in under 30 minutes. Measured average joint strengths of about 15 MPa are initially achieved for joined bodies when tested in single lap offset (SLO) compressive shear, while tuning of the interfacial composition along with a reduction in interlayer thickness, results in improved joint strengths of approximately 43 MPa. We further demonstrated SiC-SiC joining using Active Brazing Alloys (ABAs) proof of concept joining of tubular geometries. The versatility of CARUJ is demonstrated by utilizing non-contact heating via induction, to join dissimilar materials systems of SiC, SS316 and MAX phase ceramics with ABA interlayers. The localized and rapid heat application realizes a versatile material joining technique that can be extended for joining components at the plant site.

36 MATERIALS SCIENCE↗

A VIPA Spectrograph with Ultra-high Resolution and Wavelength Calibration for Astronomical Applications

A prototype spectrograph using a Virtually Imaged Phased Array (VIPA) as the main dispersion element is presented, and its performance is fully examined in our laboratory. The single-mode, fiber-fed spectrograph with simultaneous wavelength calibration possesses a spectral resolution well in excess of R≈1.12×10{sup 6} while the size of the VIPA is several orders of magnitude smaller than that of a conventional échelle with comparable resolution. In laboratory tests, the VIPA-based instrument with a homemade Yb:fiber ring laser frequency comb demonstrates a mode-to-mode tracking stability of 41 cm s{sup −1} over a period of 6 hr. The VIPA spectrograph has promising applications in various astronomical observations in which ultra-high resolution and calibration precision are imperative, such as solar physics research, exoplanet searching with the radial velocity method, and O{sub 2} detection in the atmosphere of Earth-like planets. Ultimately, feasible optimizations for night-sky observations under seeing limited conditions are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Assessment of NDE Methods to Detect Lack of Fusion in HDPE Butt Fusion Joints

Studies at the Pacific Northwest National Laboratory (PNNL) in Richland, Washington, were conducted to evaluate nondestructive examinations (NDE) coupled with mechanical testing of butt fusion joints in high-density polyethylene (HDPE) pipe for assessing lack of fusion. The work provided information to the United States Nuclear Regulatory Commission (NRC) on the effectiveness of volumetric inspection techniques of HDPE butt fusion joints in Section III, Division 1, Class 3, buried piping systems in nuclear power plants. This paper describes results from assessments using ultrasonic and microwave nondestructive techniques and mechanical testing with the high-speed tensile impact test and the side-bend test for determining joint integrity. A series of butt joints were fabricated in 3408, 12-inch (30.5-cm) IPS DR-11 HDPE material by varying the fusion parameters to create good joints and joints containing a range of lack-of-fusion conditions. Six of these butt joints were volumetrically examined with time-of-flight diffraction (TOFD), phased-array (PA) ultrasound, and the Evisive microwave system. The outer diameter (OD) weld beads were removed for microwave evaluation and the pipes ultrasonically re-evaluated. In two of the six pipes, both the outer and inner diameter (ID) weld beads were removed and the pipe joints re-evaluated. Some of the pipes were sectioned and the joints destructively evaluated with the high-speed tensile test and the side-bend test. The fusion parameters, nondestructive and destructive evaluation results have been correlated to validate the effectiveness of what each NDE technology detects and what each does not detect. There was no single NDE method that detected all of the lack-of-fusion flaws but a combination of NDE methods did detect most of the flaws.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Phase Characteristics of a U-20Pu-3Am-2Np-15Zr Metallic Alloy Containing Rare Earths

Metallic fuel alloys consisting of uranium, plutonium, and zirconium with minor additions of americium and neptunium are under evaluation for potential use to transmute long-lived transuranic actinide isotopes in fast reactors. The current irradiation test series design, designated AFC2, includes minor additions of rare earth elements to simulate expected fission product carry-over from the electrochemical molten salt reprocessing technique. The metal fuel alloys have been fabricated by an arc casting technique. The as-cast fuel alloys have been investigated for phase and thermal properties, specifically, enthalpies of transition, transition temperatures, and room temperature phase characteristics. Results and observations related to these characteristics for the “fresh” fuel alloys are provided. The alloy compositions are based on a U-20Pu-3Am-2Np-15Zr alloy, along with additions of 1 and 1.5 wt% RE (at the expense of U) where RE denotes rare earth alloy of cerium, lanthanum, praseodymium and neodymium). Phase behavior and associated transitions have been compared to available U-Pu-Zr ternary diagrams with acceptable agreement. Enthalpies of transition were deconvoluted from heating and cooling thermal traces for relatively reliable values. The rare earth additions to the base alloy have a minimal influence on the room temperature phases present, but the room temperature phases present slightly impacted the enthalpies of transition and transition temperatures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Liquid organic foams for formulation optimization : an assessment of foam linear viscoelasticity and its temporal dependence.

Liquid foams are viscoelastic liquids, exhibiting a fast relaxation attributed to local bubble motions and a slow response due to structural evolution of the intrinsically unstable system. In this work, these processes are examined in unique organic foams that differ from the typically investigated aqueous systems in two major ways: the organic foams (1) posses a much higher continuous phase viscosity and (2) exhibit a coarsening response that involves coalescence of cells. The transient and dynamic relaxation responses of the organic foams are evaluated and discussed in relation to the response of aqueous foams. The change in the foam response with increasing gas fraction, from that of a Newtonian liquid to one that is strongly viscoelastic, is also presented. In addition, the temporal dependencies of the linear viscoelastic response are assessed in the context of the foam structural evolution. These foams and characterization techniques provide a basis for testing stabilization mechanisms in epoxy-based foams for encapsulation applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MX precipitate behavior in an irradiated advanced Fe-9Cr steel: Self-ion irradiation effects on phase stability

In an effort to optimize Fe-9Cr reduced activation ferritic/martensitic (RAFM) steels and to inform the design and operation of fusion reactors, this work represents the first in a series of cohesive studies dedicated to the evolution of MX-TiC precipitates under accelerated single and dual ion irradiations. This study investigates CNA9, a simplified Fe-9Cr RAFM steel featuring initial MX-TiC precipitate densities of (2.3±0.3)×10²¹ m⁻³. This material was subjected to single self-ion irradiation at damage levels ranging from 1 to 100 displacements per atom (dpa) over a temperature range of 300 to 600°C, with a nominal dose rate of 7×10⁻⁴ dpa/s. Irradiation-induced coarsening was observed, as evidenced by statistically significant increases in mean diameter sizes, at 15 dpa at both 500°C and 600°C, whereas no coarsening was noted at 300°C or 400°C. Further, complete dissolution of precipitates occurred at damage levels of 50 and 100 dpa across the two temperatures tested (300°C and 500°C) while no significant changes were observed at any doses below 15 dpa at 500°C. Experimentally parameterized recoil resolution modeling suggests that the observed radiation stability of MX-TiC precipitates is intricately linked to diffusional changes of solutes resulting from the co-evolution of microstructural features within the experiments. The findings align with current theoretical perspectives on radiation-induced precipitate stability in complex alloys.

36 MATERIALS SCIENCE↗

Enhancing Oxygen Reduction Activity and Cr Tolerance of Solid Oxide Fuel Cell Cathodes by a Multiphase Catalyst Coating

Intermediate temperature solid oxide fuel cells (IT-SOFCs) are cost-effective and efficient energy conversion systems. Here, the sluggish oxygen reduction reaction (ORR) and the degradation of cathodes are critical challenges to the commercialization of IT-SOFCs. Here, a highly efficient multiphase (MP) catalyst coating, consisting of Ba 1–x Co 0.7 Fe 0.2 Nb 0.1 O 3–δ (BCFN) and BaCO 3 , to enhance the ORR activity and durability of the state-of-the-art lanthanum strontium cobalt ferrite (La 0.6 Sr 0.4 Co 0.2 Fe 0.8 O 3–δ , LSCF) cathode is reported. The conformal MP catalyst-coated LSCF cathode shows a polarization resistance (R p ) of 0.048 Ω cm 2 at 650 °C, about one order of magnitude smaller than that of the bare LSCF. In an accelerated Cr-poisoning test, the degradation rate of the catalyst-coated LSCF electrode is 10 –3 Ω cm 2 h –1 (0.59% h –1 ) over 200 h, only one fifth of the degradation rate of the bare LSCF electrode at 750 °C. In addition, anode-supported single cells with the MP catalyst-coated LSCF cathode show a dramatically enhanced peak power density (1.4 W cm –2 vs 0.67 W cm –2 at 750 °C) and increased durability against Cr and H 2 O. Both experimental results and density functional theory-based calculations indicate that the BCFN phase improves the ORR activity while the BaCO 3 phase enhances the stability of the LSCF cathode.

solid oxide fuel cells↗

Neurochemical Evidence of Potential Neurotoxicity After Prophylactic Cranial Irradiation

Purpose: To examine whether cerebrospinal fluid biomarkers for neuroaxonal damage, neuroglial activation, and amyloid β–related processes could characterize the neurochemical response to cranial radiation. Methods and Materials: Before prophylactic cranial irradiation (PCI) of patients with small cell lung cancer, each patient underwent magnetic resonance imaging of the brain, lumbar puncture, and Mini-Mental State Examination of cognitive function. These examinations were repeated at approximately 3 and 12 months after radiation. Results: The major findings were as follows. (1) Cerebrospinal fluid markers for neuronal and neuroglial injury were elevated during the subacute phase after PCI. Neurofilament and T-tau increased 120% and 50%, respectively, after PCI (P<.05). The same was seen for the neuroglial markers YKL-40 and glial fibrillary acidic protein, which increased 144% and 106%, respectively, after PCI (P<.05). (2) The levels of secreted amyloid precursor protein-α and -β were reduced 44% and 46%, respectively, 3 months after PCI, and the levels continued to decrease as long as 1 year after treatment (P<.05). (3) Mini-Mental State Examination did not reveal any cognitive decline, indicating that a more sensitive test should be used in future studies. Conclusion: In conclusion, we were able to detect radiation therapy–induced changes in several markers reflecting neuronal injury, inflammatory/astroglial activation, and altered amyloid precursor protein/amyloid β metabolism, despite the low number of patients and quite moderate radiation doses (20-30 Gy). These changes are hypothesis generating and could potentially be used to assess the individual risk of developing long-term symptoms of chronic encephalopathy after PCI. This has to be evaluated in large studies with extended clinical follow-up and more detailed neurocognitive assessments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗