Search NASA⌕ Search

SEARCH · Search NASA

Results for “acquisition function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,369 records · Page 76

ACE: A distributed system to manage large data archives

Competitive pressures in the oil and gas industry are requiring a much tighter integration of technical data into E and P business processes. The development of new systems to accommodate this business need must comprehend the significant numbers of large, complex data objects which the industry generates. The life cycle of the data objects is a four phase progression from data acquisition, to data processing, through data interpretation, and ending finally with data archival. In order to implement a cost effect system which provides an efficient conversion from data to information and allows effective use of this information, an organization must consider the technical data management requirements in all four phases. A set of technical issues which may differ in each phase must be addressed to insure an overall successful development strategy. The technical issues include standardized data formats and media for data acquisition, data management during processing, plus networks, applications software, and GUI's for interpretation of the processed data. Mass storage hardware and software is required to provide cost effective storage and retrieval during the latter three stages as well as long term archival. Mobil Oil Corporation's Exploration and Producing Technical Center (MEPTEC) has addressed the technical and cost issues of designing, building, and implementing an Advanced Computing Environment (ACE) to support the petroleum E and P function, which is critical to the corporation's continued success. Mobile views ACE as a cost effective solution which can give Mobile a competitive edge as well as a viable technical solution.

Daily, Mike I.↗

Pyrometer

A non-contact pyrometer and method for calibrating the same are provided. The pyrometer includes a radiation sensor configured to measure at least a portion of a radiance signal emitted from a target medium and output a voltage that is a function of an average of the absorbed radiance signal, and an optical window disposed proximate the radiation sensor and configured to control a wavelength range of the radiance signal that reaches the radiation sensor. The pyrometer may further include a reflective enclosure configured to receive the target medium therein, wherein the radiation sensor and the optical window are disposed within the reflective enclosure, an amplifier in communication with an output of the radiation sensor, and a data acquisition system in communication with an output of the amplifier.

Quince, Asia N.↗

Rapid Quantification of 237 U Specific Activity for Nuclear Forensics

In the event of an unattributed nuclear explosion, rapid assessment of the short-lived uranium isotope activity and mass can provide valuable information for subsequent forensic analysis. Rapid analysis in the field is enabled by using microfluidic chemistry and deployable instrumentation. Here, this work presents a flow chemistry system, controlled in LabVIEW, that integrates three functionalities: (1) selective extraction of uranium from the sample matrix via a 3D-printed supported liquid membrane module; (2) UV–visible absorbance spectrophotometry to measure the total uranium concentration in the strip flow; and (3) a portable CdTe γ-ray spectrometer coupled to a 3D-printed flow cell to measure 237 U activity concentration in the strip solution. The system was calibrated using standard solutions, and its functionality was demonstrated using a solution of depleted uranium spiked with 237 U. Uranium concentrations of 40–5000 μg/mL were directly quantified online using a 100 mm optical flow cell, while concentrations of 0.5–10 μg/mL were quantified online using a colorimetric reagent. The mass concentration measurement takes approximately 60 min while the activity concentration via γ-ray spectrometry varies depending on the activity of 237 U, with 1 kBq/mL requiring about 30 min of acquisition time to obtain <10% uncertainty at 1σ. This platform provides a fieldable approach for quantifying uranium mass and radioactivity relevant to postdetonation nuclear debris.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Captan+X Data Converter Integration

Fermi National Accelerator Laboratory's CAPTAN (Compact And Programmable daTa Acquisition Node) series provides a flexible hardware platform for data acquisition across a range of experiments and facilities. The latest iteration, CAPTAN+X, is built around a Kintex-7 FPGA supporting four FPGA Mezzanine Card (FMC) connections. As part of a broader laboratory effort to bring facility systems under a Model-Based Systems Engineering (MBSE) framework, CAPTAN+X is one of several systems slated to be incorporated into this modeling environment in the near term. A necessary step toward that goal is incorporating the platform's core functionality, which centers on integration with the LXD31K4 FMC, a data converter module combining dual AD9652 analog-to-digital converters and dual AD9142A digital-to-analog converters. Achieving compatibility required resolving pin-mapping conflicts between the LXD31K4's High Pin Count connector and the CAPTAN+X's available pin types, adapting a Board Support Project originally written for an UltraScale-class evaluation board to the Kintex-7 architecture, replacing incompatible primitives, restructuring clock distribution, and manually configuring chip initialization in place of an unsupported soft-processor-based approach. Functional verification of the ADC and DAC channels, followed by closed-loop testing combining both converters with real-time filtering, confirmed correct operation of the integrated system. These results establish a working hardware and firmware baseline for the CAPTAN+X platform, positioning it for future inclusion in the laboratory's growing MBSE modeling effort.

Espinoza, David [Illinois U., Urbana (main)]↗

Human factors of flight-deck checklists: The normal checklist

Although the aircraft checklist has long been regarded as the foundation of pilot standardization and cockpit safety, it has escaped the scrutiny of the human factors profession. The improper use, or the non-use, of the normal checklist by flight crews is often cited as the probable cause or at least a contributing factor to aircraft accidents. An attempt is made to analyze the normal checklist, its functions, format, design, length, usage, and the limitations of the humans who must interact with it. The development of the checklist from the certification of a new model to its delivery and use by the customer are discussed. The influence of the government, particularly the FAA Principle Operations Inspector, the manufacturer's philosophy, the airline's culture, and the end user, the pilot, influence the ultimate design and usage of this device. The effects of airline mergers and acquisitions on checklist usage and design are noted. In addition, the interaction between production pressures and checklist usage and checklist management are addressed. Finally, a list of design guidelines for normal checklists is provided.

Degani, Asaf↗

The flight performance of the Galileo orbiter USO

Results are presented in this article from an analysis of radio metric data received by the DSN stations from the Galileo spacecraft using an Ultrastable Oscillator (USO) as a signal source. These results allow the health and performance of the Galileo USO to be evaluated, and are used to calibrate this Radio Science instrument and the data acquired for Radio Science experiments such as the Redshift Observation, Solar Conjunction, and Jovian occultations. Estimates for the USO-referenced, spacecraft-transmitted frequency and frequency stability were made for 82 data acquisition passes conducted between launch (Oct. 1989) and Nov. 1991. Analyses of the spacecraft-transmitted frequencies show that the USO is behaving as expected. The USO was powered off and then back on in Aug. 1991 with no adverse effect on its performance. The frequency stabilities measured by Allan deviation are consistent with expected values due to thermal wideband noise and the USO itself at the appropriate time intervals. The Galileo USO appears to be healthy and functioning normally in a reasonable manner.

Morabito, D. D.↗

The flight performance of the Galileo orbiter USO

Results are presented from an analysis of radio metric data received by the DSN stations from the Galileo spacecraft using an Ultrastable Oscillator (USO) as a signal source. These results allow the health and performance of the Galileo USO to be evaluated, and are used to calibrate this Radio Science instrument and the data acquired for Radio Science experiments such as the Red-shift Observation, Solar Conjunction, and Jovian occultations. Estimates for the USO-referenced spacecraft-transmitted frequency and frequency stability were made for 82 data acquisition passes conducted between launch (October 1989) and November 1991. Analyses of the spacecraft-transmitted frequencies show that the USO is behaving as expected. The USO was powered off and then back on in August 1991 with no adverse effect on its performance. The frequency stabilities measured by Allan deviation are consistent with expected values due to thermal wideband noise and the USO itself at the appropriate time intervals. The Galileo USO appears to be healthy and functioning normally in a reasonable manner.

Morabito, D. D.↗

CAPTAN+X Data Converter Integration

Fermi National Accelerator Laboratory's CAPTAN (Compact And Programmable daTa Acquisition Node) series provides a flexible hardware platform for data acquisition across a range of experiments and facilities. The latest iteration, CAPTAN+X, is built around a Kintex-7 FPGA supporting four FPGA Mezzanine Card (FMC) connections. As part of a broader laboratory effort to bring facility systems under a Model-Based Systems Engineering (MBSE) framework, CAPTAN+X is one of several systems slated to be incorporated into this modeling environment in the near term. A necessary step toward that goal is incorporating the platform's core functionality, which centers on integration with the LXD31K4 FMC, a data converter module combining dual AD9652 analog-to-digital converters and dual AD9142A digital-to-analog converters. Achieving compatibility required resolving pin-mapping conflicts between the LXD31K4's High Pin Count connector and the CAPTAN+X's available pin types, adapting a Board Support Project originally written for an UltraScale-class evaluation board to the Kintex-7 architecture, replacing incompatible primitives, restructuring clock distribution, and manually configuring chip initialization in place of an unsupported soft-processor-based approach. Functional verification of the ADC and DAC channels, followed by closed-loop testing combining both converters with real-time filtering, confirmed correct operation of the integrated system. These results establish a working hardware and firmware baseline for the CAPTAN+X platform, positioning it for future inclusion in the laboratory's growing MBSE modeling effort.

Espinoza, David [Illinois U., Urbana (main)]↗

THE NEXT GENERATION VIRGO CLUSTER SURVEY (NGVS). I. INTRODUCTION TO THE SURVEY

The Next Generation Virgo Cluster Survey (NGVS) is a program that uses the 1 deg{sup 2} MegaCam instrument on the Canada-France-Hawaii Telescope to carry out a comprehensive optical imaging survey of the Virgo cluster, from its core to its virial radius-covering a total area of 104 deg{sup 2}-in the u*griz bandpasses. Thanks to a dedicated data acquisition strategy and processing pipeline, the NGVS reaches a point-source depth of g Almost-Equal-To 25.9 mag (10{sigma}) and a surface brightness limit of {mu}{sub g} {approx} 29 mag arcsec{sup -2} (2{sigma} above the mean sky level), thus superseding all previous optical studies of this benchmark galaxy cluster. In this paper, we give an overview of the technical aspects of the survey, such as areal coverage, field placement, choice of filters, limiting magnitudes, observing strategies, data processing and calibration pipelines, survey timeline, and data products. We also describe the primary scientific topics of the NGVS, which include: the galaxy luminosity and mass functions; the color-magnitude relation; galaxy scaling relations; compact stellar systems; galactic nuclei; the extragalactic distance scale; the large-scale environment of the cluster and its relationship to the Local Supercluster; diffuse light and the intracluster medium; galaxy interactions and evolutionary processes; and extragalactic star clusters. In addition, we describe a number of ancillary programs dealing with 'foreground' and 'background' science topics, including the study of high-inclination trans-Neptunian objects; the structure of the Galactic halo in the direction of the Virgo Overdensity and Sagittarius Stream; the measurement of cosmic shear, galaxy-galaxy, and cluster lensing; and the identification of distant galaxy clusters, and strong-lensing events.

79 ASTRONOMY AND ASTROPHYSICS↗

Estimation of Large-Scale Wind Field Characteristics Using Supervisory Control and Data Acquisition Measurements

As the wind energy industry continues to push for increased power production and lower cost of energy, the focus of research has expanded from individual turbines to entire wind farms. Among a host of interesting problems to be solved when considering the wind farm as a whole, we consider the challenge of scalar field estimation, based on information already collected at the individual turbine level. We aim to estimate the large-scale, low-frequency characteristics of the wind field, such as the mean wind direction and the overall decrease in wind speed across the farm, and employ a Kalman filter that models the wind field using a polynomial function. We compare the proposed method’s performance to both a simple averaging technique and filtering of individual turbine measurements. The method presented is not limited to wind turbines and is applicable in other situations where multiple remote agents are used to estimate a scalar field.

estimation↗

A novel digital pulse processing architecture for nuclear instrumentation

The field of nuclear instrumentation covers a wide range of applications, including counting, spectrometry, pulse shape discrimination and multi-channel coincidence. These applications are the topic of many researches, new algorithms and implementations are constantly proposed thanks to advances in digital signal processing. However, these improvements are not yet implemented in instrumentation devices. This is especially true for neutron-gamma discrimination applications which traditionally use charge comparison method while literature proposes other algorithms based on frequency domain or wavelet theory which show better performances. Another example is pileups which are generally rejected while pileup correction algorithms also exist. These processes are traditionally performed offline due to two issues. The first is the Poissonian characteristic of the signal, composed of random arrival pulses which requires to current architectures to work in data flow. The second is the real-time requirement, which implies losing pulses when the pulse rate is too high. Despite the possibility of treating the pulses independently from each other, current architectures paralyze the acquisition of the signal during the processing of a pulse. This loss is called dead-time. These two issues have led current architectures to use dedicated solutions based on re-configurable components like Field Programmable Gate Arrays (FPGAs) to overcome the need of performance necessary to deal with dead-time. However, dedicated hardware algorithm implementations on re-configurable technologies are complex and time-consuming. For all these reasons, a programmable Digital pulse Processing (DPP) architecture in a high level language such as Cor C++ which can reduce dead-time would be worthwhile for nuclear instrumentation. This would reduce prototyping and test duration by reducing the level of hardware expertise to implement new algorithms. However, today's programmable solutions do not meet the need of performance to operate online and not allow scaling with the increase in the number of measurement channel. That is why an innovative DPP architecture is proposed in this paper. This architecture is able to overcome dead-time while being programmable and is flexible with the number of measurement channel. Proposed architecture is based on an innovative execution model for pulse processing applications which can be summarized as follow. The signal is not composed of pulses only, consequently, pulses processing does not have to operate on the entire signal. Therefore, the first step of our proposal is pulse extraction by the use of dedicated components named pulse extractors. The triggering step can be achieved after the analog-to-digital conversion without any signal shaping or filtering stages. Pileup detection and accurate pulse time stamping are done at this stage. Any application downstream this step can work on adaptive variable-sized array of samples simplifying pulse processing methods. Then, once the data flow is broken, it is possible to distribute pulses on Functional Units (FUs) which perform processing. As the date of each pulse is known, they can be processed individually out-of-order to provide the results. To manage the pulses distribution, a scheduler and an interconnection network are used. pulses are distributed on the first FU which is not busy without congesting the interconnection network. For this reason, the process duration does not result anymore in dead-time if there are enough FUs. FUs are designed to be standalone and to comprises at least a programmable general purpose processor (ARM, Microblaze) allowing the implementation of complex algorithms without any modification of the hardware. An acquisition chain is composed of a succession of algorithms which lead to organize our FUs as a software macro-pipeline, A simple approach consists in assigning one algorithm per FU. Consequently, the global latency becomes the worst latency of algorithms execution on FU. Moreover, as algorithms are executed locally - i.e. on a FU - this approach limits shared memory requirement. To handle multichannel, we propose FUs sharing, this approach maximize the chance to find a non-busy FU to process an incoming pulse. This is possible since each channel receive random event independently, the pulse extractors associated to them do not necessarily need to access simultaneously to all Computing resources at the same time to distribute their pulses. The major contribution of this paper is the proposition of an execution model and its associated hardware programmable architecture for digital pulse processing that can handle multiple acquisition channels while maintaining the scalability thanks to the use of shared resources. This execution model and associated architecture are validated by simulation of a cycle accurate architecture SystemC model. Proposed architecture shows promising results in terms of scalability while maintaining zero dead-time. This work also permit the sizing of hardware resources requirement required for a predefined set of applications. Future work will focus on the interconnection network and a scheduling policy that can exploit the variable-length of pulses. Then, the hardware implementation of this architecture will be performed and tested for a representative set of application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Virtual Microscope Views of the Apollo 11 and 12 Lunar Samples

The Apollo virtual microscope is a means of viewing, over the Internet, polished thin sections of every rock in the Apollo lunar sample collections via software, duplicating many of the functions of a petrological microscope, is described. Images from the Apollo 11 and 12 missions may be viewed at: www.virtualmicroscope.org/content/apollo. Introduction: During the six NASA missions to the Moon from 1969-72 a total of 382 kilograms of rocks and soils, often referred to as "the legacy of Apollo", were collected and returned to Earth. A unique collection of polished thin sections (PTSs) was made from over 400 rocks by the Lunar Sample Curatorial Facility at the Johnson Spacecraft Center (JSC), Houston. These materials have been available for loan to approved PIs but of course they can't be simultaneously investigated by several researchers unless they are co-located or the sample is passed back and forward between them by mail/hand carrying which is inefficient and very risky for irreplaceable material. When The Open University (OU), the world's largest Distance Learning Higher Education Establishment found itself facing a comparable problem (how to supply thousands of undergraduate students with an interactive petrological microscope and a personal set of thin sections), it decided to develop a software tool called the Virtual Microscope (VM). As a result it is now able to make the unique and precious collection of Apollo specimens universally available as a resource for concurrent study by anybody in the world's Earth and Planetary Sciences community. Herein, we describe the first steps of a collaborative project between OU and the Johnson Space Center (JSC) Curatorial Facility to record a PTS for every lunar rock, beginning with those collected by the Apollo 11 and 12 missions. Method: Production of a virtual microscope dedicated to a particular theme divides into four main parts - photography, image processing, building and assembly of virtual microscope components, and publication on a website. Two large research quality microscopes are used to collect all the images required for a virtual microscope. The first is part of an integrated package that utilizes Leica PowerMosaic software and a motorised XYZ stage to generate large area mosaics. It includes a fast acquisition camera and depending on the PTS size normally is used to produce seamless mosaic images consisting of 100-500 individual photographs. If the sample is suitable, three mosaics of each sample are recorded - plane polarised light, between crossed polars and reflected light. In order for the VM to be a true petrological microscope it is necessary to recreate the features of a rotating stage and perform observations using filters to produce polarised light. Thus the petrological VM includes the capability of seeing changes in optical properties (pleochroism and birefringence) during rotation allowing mineral identification. The second microscope in the system provides the functions of the rotating stage. To this microscope we have added a robotically controlled motor to acquire seventy-two images (5 degree intervals) in plane polarised light and between crossed polars. To process the images acquired from the two microscopes involves a combination of proprietary software (Photoshop) and our own in-house code. The final stage involves assembling all the components in an HTML5 environment. Pathfinder investigations: We have undertaken a number of pilot studies to demonstrate the efficacy of the petrological microscope with lunar samples. The first was to make available on-line images collected from the Educational Package of Apollo samples provided by NASA to the UK STFC (Science and Technical Facilities Council) for loan as educational material e.g. for schools. The real PTSs of the samples are now no longer sent out to schools removing the risks associated with transport, accidental breakage and eliminating the possibility of loss. The availability of lunar sample VM-related material was further extended to include twenty-eight specimens from all of the Apollo missions. Some of these samples were made more generally available through an ibook entitled "Moon Rocks: an introduction to the Geology of the Moon," free from the Apple Bookstore. Research possibilities: Although the Virtual Microscope was originally conceived as a teaching aid and was later recognised as a means of public outreach and engagement, we now realize that it also has enormous potential as a high level research tool. Following discussions with the JSC Curators we have received Curation and Analysis Planning Team for Extraterrestrial Materials (CAPTEM) permission to embark on a programme of digitizing the entire lunar sample PTS collection for all three of the above purposes. By the time of the 47th Lunar and Planetary Science Conference (LPSC) we will have completed 81 rocks collected during the Apollo 11 and 12 missions and the data, with cross-links to the Lunar Sample Compendium will go live on the Web at the 47th LPSC. The VM images of the Apollo 11 (41 VM images) and 12 (40 VM images) missions can be viewed at: http:/www.virtualmicroscope.org/content/apollo. The lunar sample VM will enable large numbers of skilled/unskilled microscopists (professional and amateur researchers, educators and students, enthusiasts and the simply curious non-scientists) to share the information from a single sample. It will mean that all the PTSs already cut, even historical ones, could be available for new joint investigations or private study. The scientific return from the collection will increase exponentially as a result of further debate and discussion. Simultaneously the VM will remove the need for making unnecessary multiple samplings, avoid consignment of delicate/breakable specimens (all of which are priceless) to insecure mail/courier services and reduce direct labour and indirect costs, travel budgets and unproductive travelling time necessary for co-location of collaborating researchers. For the future we have already recognized further potential for virtual technology. There is nothing that a petrologist likes more than to see the original rock as a hand specimen. It is entirely possible to recreate virtual hand specimens with 3-D hard and software, already developed for viewing fossils, located within the Curatorial Facility, http://curator.jsc.nasa.gov/lunar/lsc/index.cfm.

Gibson, E. K.↗

GUN4 appeared early in cyanobacterial evolution

Photosynthesis relies on chlorophylls, which are synthesized via a common tetrapyrrole trunk pathway also leading to heme, vitamin B12, and other pigmented cofactors. The first committed step for chlorophyll biosynthesis is insertion of magnesium into protoporphyrin IX by magnesium chelatase. Magnesium chelatase is composed of H-, I-, and D-subunits, with the tetrapyrrole substrate binding to the H-subunit. This subunit is rapidly inactivated in the presence of substrate, light, and oxygen, so oxygenic photosynthetic organisms require mechanisms to protect magnesium chelatase from similar loss of function. An additional protein, GUN4, binds to the H-subunit and to tetrapyrroles. GUN4 has been proposed to serve this protective role via its ability to bind linear tetrapyrroles (bilins). In the current work, we probe the origins of bilin binding by GUN4 via comparative phylogenetic analysis and biochemical validation of a conserved bilin-binding motif. Based on our results, we propose that bilin-binding GUN4 proteins arose early in cyanobacterial evolution and that this early acquisition represents an ancient adaptation for maintaining chlorophyll biosynthesis in the presence of light and oxygen.

59 BASIC BIOLOGICAL SCIENCES↗

An analysis of the uncertainty and bias in DCE-MRI measurements using the spoiled gradient-recalled echo pulse sequence

Purpose: The pharmacokinetic parameters derived from dynamic contrast-enhanced (DCE) MRI have been used in more than 100 phase I trials and investigator led studies. A comparison of the absolute values of these quantities requires an estimation of their respective probability distribution function (PDF). The statistical variation of the DCE-MRI measurement is analyzed by considering the fundamental sources of error in the MR signal intensity acquired with the spoiled gradient-echo (SPGR) pulse sequence. Methods: The variance in the SPGR signal intensity arises from quadrature detection and excitation flip angle inconsistency. The noise power was measured in 11 phantoms of contrast agent concentration in the range [0–1] mM (in steps of 0.1 mM) and in onein vivo acquisition of a tumor-bearing mouse. The distribution of the flip angle was determined in a uniform 10 mM CuSO{sub 4} phantom using the spin echo double angle method. The PDF of a wide range of T1 values measured with the varying flip angle (VFA) technique was estimated through numerical simulations of the SPGR equation. The resultant uncertainty in contrast agent concentration was incorporated in the most common model of tracer exchange kinetics and the PDF of the derived pharmacokinetic parameters was studied numerically. Results: The VFA method is an unbiased technique for measuringT1 only in the absence of bias in excitation flip angle. The time-dependent concentration of the contrast agent measured in vivo is within the theoretically predicted uncertainty. The uncertainty in measuring K{sup trans} with SPGR pulse sequences is of the same order, but always higher than, the uncertainty in measuring the pre-injection longitudinal relaxation time (T1{sub 0}). The lowest achievable bias/uncertainty in estimating this parameter is approximately 20%–70% higher than the bias/uncertainty in the measurement of the pre-injection T1 map. The fractional volume parameters derived from the extended Tofts model were found to be extremely sensitive to the variance in signal intensity. The SNR of the pre-injection T1 map indicates the limiting precision with which K{sup trans} can be calculated. Conclusions: Current small-animal imaging systems and pulse sequences robust to motion artifacts have the capacity for reproducible quantitative acquisitions with DCE-MRI. In these circumstances, it is feasible to achieve a level of precision limited only by physiologic variability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-time computer data system for the 40- by 80-foot wind tunnel facility at Ames Research Center

The background material and operational concepts of a computer-based system for an operating wind tunnel are described. An on-line real-time computer system was installed in a wind tunnel facility to gather static and dynamic data. The computer system monitored aerodynamic forces and moments of periodic and quasi-periodic functions, and displayed and plotted computed results in real time. The total system is comprised of several off-the-shelf, interconnected subsystems that are linked to a large data processing center. The system includes a central processor unit with 32,000 24-bit words of core memory, a number of standard peripherals, and several special processors; namely, a dynamic analysis subsystem, a 256-channel PCM-data subsystem and ground station, a 60-channel high-speed data acquisition subsystem, a communication link, and static force and pressure subsystems. The role of the test engineer as a vital link in the system is also described.

Cambra, J. M.↗

Welding process modelling and control

The research and analysis performed, and software developed, and hardware/software recommendations made during 1992 in development of the PC-based data acquisition system for support of Welding Process Modeling and Control is reported. A need was identified by the Metals Processing Branch of NASA Marshall Space Flight Center, for a mobile data aquisition and analysis system, customized for welding measurement and calibration. Several hardware configurations were evaluated and a PC-based system was chosen. The Welding Measurement System (WMS) is a dedicated instrument, strictly for the use of data aquisition and analysis. Although the WMS supports many of the functions associated with the process control, it is not the intention for this system to be used for welding process control.

Romine, Peter L.↗

A Global End-Member Approach to Derive aCDOM(440) from Near-Surface Optical Measurements

This study establishes an optical inversion scheme for deriving the absorption coefficient of colored (or chromophoric, depending on the literature) dissolved organic material (CDOM) at the 440 nm wavelength, which can be applied to global water masses with near-equal efficacy. The approach uses a ratio of diffuse attenuation coefficient spectral end members, i.e., a short and long wavelength pair. The global perspective is established by sampling "extremely" clear water plus a generalized extent in turbidity and optical properties that each span three decades of dynamic range. A unique data set was collected in oceanic, coastal, and inland waters (as shallow as 0.6 m) from the North Pacific Ocean, the Arctic Ocean, Hawaii, Japan, Puerto Rico, and the east and west coasts of the United States. The data were partitioned using subjective categorizations to define a validation quality subset of conservative water masses, i.e., the inflow and outflow of properties constrain the range in the gradient of a constituent, plus 15 subcategories of water masses that were not evolving conservatively. The dependence on subcategories was confirmed with an objective methodology based on cluster analysis techniques. The latter defined five distinct classes with validation quality data present in all classes, but which also decreased in percent composition as a function of increasing class number and optical complexity. Four different algorithms based on different validation quality end members were validated with accuracies of 1.–6.2 %, wherein pairs with the largest spectral span were most accurate. Although algorithm accuracy decreased with the inclusion of more subcategories containing non-conservative water masses, changes to the algorithm fit were small when a preponderance of subcategories were included. The high accuracy for all end-member algorithms was the result of data acquisition and data processing improvements, e.g., increased vertical sampling resolution to less than 1mm and a boundary constraint to mitigate wave focusing effects, respectively. An independent evaluation with a historical database confirmed the consistency of the algorithmic approach and its application to quality assurance, e.g., to flag data outside expected ranges, identify suspect spectra, and objectively determine the in-water extrapolation interval by converging agreement for all applicable end-member algorithms. The legacy data exhibit degraded performance (as 44 % uncertainty) due to a lack of high-quality near-surface observations, especially for clear waters wherein wave-focusing effects are problematic. The novel optical approach allows the in situ estimation of an in-water constituent in keeping with the accuracy obtained in the laboratory.

Stanford B Hooker↗

Landsat Derived Bathymetry of Lakes on the Arctic Coastal Plan of Northern Alaska

The Pleistocene sand sea on the Arctic Coastal Plain (ACP) of northern Alaska is underlain by anancient sand dune field, a geological feature that affects regional lake characteristics. Many of these lakes, whichcover approximately 20 % of the Pleistocene sand sea, are relatively deep (up to 25 m). In addition to the nat-ural importance of ACP sand sea lakes for water storage, energy balance, and ecological habitat, the need forwinter water for industrial development and exploration activities makes lakes in this region a valuable resource.However, ACP sand sea lakes have received little prior study. Here, we collect in situ bathymetric data to test12 model variants for predicting sand sea lake depth based on analysis of Landsat-8 Operational Land Imager(OLI) images. Lake depth gradients were measured at 17 lakes in midsummer 2017 using a Humminbird 798ciHD SI Combo automatic sonar system. The field-measured data points were compared to red–green–blue (RGB)bands of a Landsat-8 OLI image acquired on 8 August 2016 to select and calibrate the most accurate spectral-depth model for each study lake and map bathymetry. Exponential functions using a simple band ratio (withbands selected based on lake turbidity and bed substrate) yielded the most successful model variants. For eachlake, the most accurate model explained 81.8 % of the variation in depth, on average. Modeled lake bathymetrieswere integrated with remotely sensed lake surface area to quantify lake water storage volumes, which rangedfrom 1.056×10−3to 57.416×10−3km3. Due to variations in depth maxima, substrate, and turbidity betweenlakes, a regional model is currently infeasible, rendering necessary the acquisition of additional in situ datawith which to develop a regional model solution. Estimating lake water volumes using remote sensing will fa-cilitate better management of expanding development activities and serve as a baseline by which to evaluatefuture responses to ongoing and rapid climate change in the Arctic. All sonar depth data and modeled lakebathymetry rasters can be freely accessed at https://doi.org/10.18739/A2SN01440 (Simpson and Arp, 2018) andhttps://doi.org/10.18739/A2HT2GC6G (Simpson, 2019), respectively.

Claire E Simpson↗