Search NASA⌕ Search

SEARCH · Search NASA

Results for “Signal generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Quantification of the internal quantum efficiency in GaN via analysis of the heat generated by non-radiative recombination processes

The internal quantum efficiency (IQE) in a GaN epilayer is quantified using transient lens (TL) spectroscopy and numerical simulations. TL spectroscopy can optically detect temperature and carrier changes induced in a photo-pumped GaN layer, and the observed temperature change is closely associated with non-radiative recombination processes that create heat. Then numerically solving diffusion equations, which represent the diffusion processes of the photo-generated heat and carriers, provide the spatiotemporal distributions. These distributions are subsequently converted into the refractive index distributions, which act as transient convex or concave lenses. Finally, ray-tracing simulations predict the TL signals. Comparing the experimentally obtained and simulated TL signals quantifies the generated heat and the IQE without the often-adopted assumption that non-radiative recombination processes are negligible at low temperatures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

System and method for high power diode based additive manufacturing

The present disclosure relates to a system for performing an Additive Manufacturing (AM) fabrication process on a powdered material, deposited as a powder bed and forming a substrate. The system makes use of a laser for generating a laser beam, and an optical subsystem. The optical subsystem is configured to receive the laser beam and to generate an optical signal comprised of electromagnetic radiation sufficient to melt or sinter the powdered material. The optical subsystem uses a digitally controlled mask configured to pattern the optical signal as needed to melt select portions of a layer of the powdered material to form a layer of a 3D part. A power supply and at least one processor are also included for generating a plurality of different power density levels selectable based on a specific material composition, absorptivity and diameter of the powder particles, and a known thickness of the powder bed. The powdered material is used to form the 3D part in a sequential layer-by-layer process.

El-Dasher, Bassem S.↗

Development of Thermal Infrared Sensor to Supplement Operational Land Imager

The thermal infrared sensor (TIRS) is a quantum well infrared photodetector (QWIP)-based instrument intended to supplement the Operational Land Imager (OLI) for the Landsat Data Continuity Mission (LDCM). The TIRS instrument is a far-infrared imager operating in the pushbroom mode with two IR channels: 10.8 and 12 m. The focal plane will contain three 640 ~512 QWIP arrays mounted onto a silicon substrate. The readout integrated circuit (ROIC) addresses each pixel on the QWIP arrays and reads out the pixel value (signal). The ROIC is controlled by the focal plane electronics (FPE) by means of clock signals and bias voltage value. The means of how the FPE is designed to control and interact with the TIRS focal plane assembly (FPA) is the basis for this work. The technology developed under the FPE is for the TIRS focal plane assembly (FPA). The FPE must interact with the FPA to command and control the FPA, extract analog signals from the FPA, and then convert the analog signals to digital format and send them via a serial link (USB) to a computer. The FPE accomplishes the described functions by converting electrical power from generic power supplies to the required bias power that is needed by the FPA. The FPE also generates digital clocking signals and shifts the typical transistor-to-transistor logic (TTL) to }5 V required by the FPA. The FPE also uses an application- specific integrated circuit (ASIC) named System Image, Digitizing, Enhancing, Controlling, And Retrieving (SIDECAR) from Teledyne Corp. to generate the clocking patterns commanded by the user. The uniqueness of the FPE for TIRS lies in that the TIRS FPA has three QWIP detector arrays, and all three detector arrays must be in synchronization while in operation. This is to avoid data skewing while observing Earth flying in space. The observing scenario may be customized by uploading new control software to the SIDECAR.

Shu, Peter↗

Alignment system for encoders

An improved encoder alignment system is disclosed which provides an indication of the extent of misalignment and a measure of the rate at which the misalignment may be changing. The invention is adapted for use with a conventional encoder which provides a digital coarse word having at least significant bit and a digital fine word having a least significant bit and a most significant bit. The invention generates the exclusive or of the least significant bit of the coarse digital signal and the least significant bit of the fine digital signal to provide a first signal. The invention then generates the exclusive or of the first signal and the complement of the most significant bit of the fine digital signal to provide an output signal which represents the misalignment of the encoder.

Villani, Daniel D.↗

D-DMTD: Digital Dual Mixer Time Difference

The digital design discussed in the following document is inspired by the digital dual mixer time difference circuit and based on the white paper, Digital femtosecond time difference circuit for CERN's timing system. DMTD is originally an analog technique that measures the time difference between two events with high precision using a commercial time interval counter. Our project applies this analog concept to a digital system programmed onto a Microsemi ProASIC3E FPGA (Field- Programmable Gate Array). D-DMTD is a digital system theoretically capable of measuring the time difference between two digital clock signals with very fine resolution (sub-picosecond) using a relatively low frequency counter. The system essentially acts as a digital phase detector with femtosecond time resolution. The main concern with this processing technique is its feasibility and accuracy when implemented on an FPGA. Another concern is the environmentally-induced, horizontal phase noise in the digital signals; this 'litter" jeopardizes the fidelity of the clocks and generates glitches in the signals. Thus, the majority of the work was focused on determining under what conditions the digital design performs optimally and generates the most accurate estimations for the phase shift.

42 ENGINEERING↗

Coherence Spectroscopy in the Condensed Phase: Insights into Molecular Structure, Environment, and Interactions

The role of coherences, or coherently excited superposition states, in complex condensed-phase systems has been the topic of intense interest and debate for a number of years. In many cases, coherences have been utilized as spectators of ultrafast dynamics or for identifying couplings between electronic states. In rare cases, they have been found to drive excited state dynamics directly. Interestingly though, the utilization of coherences as a tool for high-detail vibronic spectroscopy has largely been overlooked until recently, despite their encoding of key information regarding molecular structure, electronically sensitive vibrational modes, and intermolecular interactions. Furthermore, their detection in the time domain makes for a highly comprehensive spectroscopic technique wherein the phase and dephasing times are extracted in addition to amplitude and intensity, an element not afforded in analogous frequency domain “steady-state” measurements. However, practical limitations arise in disentangling the large number of coherent signals typically accessed in broadband nonlinear spectroscopic experiments, often complicating assignment of the origin and type of coherences generated. Two-dimensional electronic spectroscopy (2DES) affords an avenue by which to disperse and decompose the large number of coherent signals generated in nonlinear experiments, facilitating the assignment of various types of quantum coherences. 2DES takes advantage of the broad bandwidth necessary for achieving the high time resolution desired for ultrafast dynamics and coherence generation by resolving the excitation axis to detect all excitation channels independently. This feature is beneficial for following population dynamics such as electronic energy transfer, and 2DES has become the choice method for such studies. Simultaneously, coherences arise as oscillations at well-defined coordinates across the 2D map often atop those evolving population signals. By isolating the coherent contribution to the 2DES data and Fourier transforming along the population time, a 3D spectral representation of the coherent 2D data is generated, and coherences are then ordered by their oscillation frequency, ν2. Individual coherences can then be selected by their frequency and evaluated via their distinct “2D coherence” spectra, yielding a significantly more distinctive set of spectroscopic signatures over other 1D methodologies and single-point 2DES analysis. Given that coherences of different origin result in unique 2D coherence spectra, these characteristics can be catalogued and compared directly against experiment for prompt assignment, a strategy not afforded by traditional 2DES analysis. In this Account, a structure-driven time-independent spectral model is discussed and employed to compare the 2D fingerprints of various coherences to experimental 2D coherence spectra. The frequency-domain approach can easily integrate ab initio derived vibronic parameters, and its correspondence with experimental coherence spectra of a model compound is demonstrated. Several examples and applications are discussed herein, from 2D Franck–Condon analysis of a model compound, to identifying the signatures of interpigment vibronic coupling in a photosynthetic light-harvesting complex. The 3D spectral approach to 2DES provides remarkable spectroscopic detail, in turn leading to new insights in molecular structure and interactions, which complement the time-resolved dynamics simultaneously recorded. The approach presented herein has the potential to distill down the convoluted set of nonlinear signals appearing in 2D coherent spectra, making the technique more amenable to high-detail vibronic spectroscopy in inherently complex condensed phase systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exposing Key Vibrational Contributions to Properties of Organic Molecular Solids with High Signal, Low Frequency Neutron Spectroscopy and Ab Initio Simulations

Stability and response of supramolecular forms is important to many areas in materials science, and contributions from vibrations can be crucial. In this study, we have collected the first spectra of organic molecular crystals and polymorphic cocrystals using the next-generation, high-signal VISION spectrometer in the far-infrared (FIR) and mid-infrared (MIR) range. Unambiguously different spectral signatures were found for carbamazepine and two polymorphs of the carbamazepine-saccharin cocrystal, including numerous modes undetectable with optical methods. For FIR-range frequencies, in addition to correct calculation of peak positions, accurate line-shape features were reproducible by simulation using ab initio vibrational calculations. Finally, high confidence spectral assignments and thermochemical information for this region are thus expected, and a benchmark for vibrational ab initio calculations is provided, creating a significant addition to methods used in investigation and design of organic materials.

36 MATERIALS SCIENCE↗

The large enriched germanium experiment for neutrinoless double beta decay (LEGEND)

We report the observation of neutrinoless double-beta decay (0νββ) would show that lepton number is violated, reveal that neu-trinos are Majorana particles, and provide information on neutrino mass. A discovery-capable experiment covering the inverted ordering region, with effective Majorana neutrino masses of 15 - 50 meV, will require a tonne-scale experiment with excellent energy resolution and extremely low backgrounds, at the level of ~0.1 count /(FWHM·t·yr) in the region of the signal. The current generation 76 Ge experiments GERDA and the Majorana Demonstrator, utilizing high purity Germanium detectors with an intrinsic energy resolution of 0.12%, have achieved the lowest backgrounds by over an order of magnitude in the 0νββ signal region of all 0νββ experiments. Building on this success, the LEGEND collaboration has been formed to pursue a tonne-scale 76 Ge experiment. Lastly, the collaboration aims to develop a phased 0νββ experimental program with discovery potential at a half-life approaching or at 10 28 years, using existing resources as appropriate to expedite physics results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Does the vestibular system contribute to head direction cell activity in the rat?

Head direction cells (HDC) located in several regions of the brain, including the anterior dorsal nucleus of the thalamus (ADN), postsubiculum (PoS), and lateral mammillary nuclei (LMN), provide the neural substrate for the determination of head direction. Although activity of HDC is influenced by various sensory signals and internally generated cues, lesion studies and some anatomical and physiological evidence suggest that vestibular inputs are critical for the maintenance of directional sensitivity of these cells. However, vestibular inputs must be transformed considerably in order to signal head direction, and the neuronal circuitry that accomplishes this signal processing has not been fully established. Furthermore, it is unclear why the removal of vestibular inputs abolishes the directional sensitivity of HDC, as visual and other sensory inputs and motor feedback signals strongly affect the firing of these neurons and would be expected to maintain their directional-related activity. Further physiological studies will be required to establish the role of vestibular system in producing HDC responses, and anatomical studies are needed to determine the neural circuitry that mediates vestibular influences on determination of head direction.

Review, Tutorial↗

Unitary Shaft-Angle and Shaft-Speed Sensor Assemblies

The figure depicts a unit that contains a rotary-position or a rotary-speed sensor, plus electronic circuitry necessary for its operation, all enclosed in a single housing with a shaft for coupling to an external rotary machine. This rotation sensor unit is complete: when its shaft is mechanically connected to that of the rotary machine and it is supplied with electric power, it generates an output signal directly indicative of the rotary position or speed, without need for additional processing by other circuitry. The incorporation of all of the necessary excitatory and readout circuitry into the housing (in contradistinction to using externally located excitatory and/or readout circuitry) in a compact arrangement is the major difference between this unit and prior rotation-sensor units. The sensor assembly inside the housing includes excitatory and readout integrated circuits mounted on a circular printed-circuit board. In a typical case in which the angle or speed transducer(s) utilize electromagnetic induction, the assembly also includes another circular printed-circuit board on which the transducer windings are mounted. A sheet of high-magnetic permeability metal ("mu metal") is placed between the winding board and the electronic-circuit board to prevent spurious coupling of excitatory signals from the transducer windings to the readout circuits. The housing and most of the other mechanical hardware can be common to a variety of different sensor designs. Hence, the unit can be configured to generate any of variety of outputs by changing the interior sensor assembly. For example, the sensor assembly could contain an analog tachometer circuit that generates an output proportional (in both magnitude and sign or in magnitude only) to the speed of rotation.

Alhorn, Dean C.↗

Hardware Demonstration: Frequency Spectra of Transients

Radiated emissions measurements as specified by MIL-STD-461 are performed in the frequency domain, which is best suited to continuous wave (CW) types of signals. However, many platforms implement signals that are single event pulses or transients. Such signals can potentially generate momentary radiated emissions that can cause interference in the system, but they may be missed with traditional measurement techniques. This demonstration provides measurement and analysis techniques that effectively evaluate the potential emissions from such signals in order to evaluate their potential impacts to system performance.

EMI↗

Characterization of a fiber-coupled Al{sub 2}O{sub 3}:C luminescence dosimetry system for online in vivo dose verification during {sup 192}Ir brachytherapy

A prototype of a new dose-verification system has been developed to facilitate prevention and identification of dose delivery errors in remotely afterloaded brachytherapy. The system allows for automatic online in vivo dosimetry directly in the tumor region using small passive detector probes that fit into applicators such as standard needles or catheters. The system measures the absorbed dose rate (0.1 s time resolution) and total absorbed dose on the basis of radioluminescence (RL) and optically stimulated luminescence (OSL) from aluminum oxide crystals attached to optical fiber cables (1 mm outer diameter). The system was tested in the range from 0 to 4 Gy using a solid-water phantom, a Varian GammaMed Plus {sup 192}Ir PDR afterloader, and dosimetry probes inserted into stainless-steel brachytherapy needles. The calibrated system was found to be linear in the tested dose range. The reproducibility (one standard deviation) for RL and OSL measurements was 1.3%. The measured depth-dose profiles agreed well with the theoretical expectations computed with the EGSNRC Monte Carlo code, suggesting that the energy dependence for the dosimeter probes (relative to water) is less than 6% for source-to-probe distances in the range of 2-50 mm. Under certain conditions, the RL signal could be greatly disturbed by the so-called stem signal (i.e., unwanted light generated in the fiber cable upon irradiation). The OSL signal is not subject to this source of error. The tested system appears to be adequate for in vivo brachytherapy dosimetry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Method of and apparatus for double-exposure holographic interferometry

Double-exposure holographic interferometry is carried out using first and second lasers responsive to respective applied firing signals for producing respective pulsed output beams. An optical system is provided oriented such that the output beams of the lasers produce coinciding scene and reference beams. An initiator circuit generates and applies a firing signal to the first laser; and a timer/firing device responsive to the generation of a firing signal by the initiator circuit, generates and applies a firing signal to the second laser a predetermined period of time later.

Witherow, W. K.↗

Method and system for measuring sound velocity

A method and system for determining the speed of sound in a fluidic medium by determining the travel time of an acoustical signal a predetermined distance in a fluidic medium by generating a cyclical reference signal of a predetermined frequency and transmitting a portion of the reference signal through the medium. The transmitted portion of the reference signal is received after travelling a predetermined distance in the fluidic medium. The cycles of the cyclical reference signal are counted during the period of time between the transmitting and receiving of the portion of the reference signal wherein the travel time of the portion of the reference signal, is the number of cycle counts divided by the frequency. The speed of the acoustical signal through the fluidic medium is a function of the path length divided by the travel time.

Boegeman, Dwight E.↗

Multi-channel pulsed valve inlet system and method

A multichannel inlet system for a mass spectrometer includes a plurality of valve assemblies coupled to a manifold, and a pulsed valve driver. The manifold is configured to be connected in fluid connection with an ion trap of the mass spectrometer. Each valve assembly includes a valve and an injection port operably coupled to receive the reagent. The valve has an actuated state in which the valve provides fluid communication between the injection port and the manifold, and an unactuated state in which the valve substantially prevents fluid communication between the injection port and the manifold. The pulsed valve driver is operably connected to receive a pulse signal sequence from a processor, and is configured to generate pulsed valve drive signals for one or more of the valves based on the pulse signal sequence to cause a corresponding one of the valves to be in the actuated state.

Kenttamaa, Hilkka↗

Systems and methods for monitoring organisms within an aquatic environment

Systems and methods for monitoring organisms within an aquatic environment are described. According to one aspect, an injectable acoustic transmission device includes a body configured to be injected inside of an organism, a transducer within the body and configured to convert a plurality of electrical signals into a plurality of data transmissions which are transmitted externally of the body and the organism, a plurality of circuit components within the body and configured to use electrical energy from a power source to generate the electrical signals which are provided to the transducer, and wherein the transducer defines an internal volume and at least one of the circuit components is provided within the internal volume of the transducer.

Deng, Z. Daniel↗

THE FIRST VERY LONG BASELINE INTERFEROMETRIC SETI EXPERIMENT

The first Search for Extra-Terrestrial Intelligence (SETI) conducted with very long baseline interferometry (VLBI) is presented. By consideration of the basic principles of interferometry, we show that VLBI is efficient at discriminating between SETI signals and human generated radio frequency interference (RFI). The target for this study was the star Gliese 581, thought to have two planets within its habitable zone. On 2007 June 19, Gliese 581 was observed for 8 hr at 1230-1544 MHz with the Australian Long Baseline Array. The data set was searched for signals appearing on all interferometer baselines above five times the noise limit. A total of 222 potential SETI signals were detected and by using automated data analysis techniques were ruled out as originating from the Gliese 581 system. From our results we place an upper limit of 7 MW Hz{sup -1} on the power output of any isotropic emitter located in the Gliese 581 system within this frequency range. This study shows that VLBI is ideal for targeted SETI including follow-up observations. The techniques presented are equally applicable to next-generation interferometers, such as the long baselines of the Square Kilometre Array.

79 ASTRONOMY AND ASTROPHYSICS↗