Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

{sup 99}Mo Production at KIPT Neutron Source Facility

Argonne National Laboratory (ANL) and Kharkov Institute of Physics and Technology (KIPT) have cooperated on the construction of the Neutron Source Facility (NSF) at KIPT, Kharkov (Ukraine). The NSF facility consists of an electron accelerator driven system (ADS) generating 300 kW of thermal power for multiple applications, including medical isotope production. ANL performed extensive analyses including medical isotopes production, reactivity monitoring, operations and control, refueling, cold neutron source design, target design,and radiation shielding. The present study focuses on the use of the KIPT NSF for medical isotope production. Medical isotopes are radioactive isotopes with short half-lives used in diagnostic and therapeutic medical procedures. For example, brain cancer is difficult to treat by ordinary surgery and only brachytherapy with {sup 131}Cs, which has 9.7 days half-life, has shown effective results on the patients. {sup 99m}Tc is the most common medical isotope used in medical diagnoses because the wavelength of its gamma radiation (8.8 pm) is about the same as the conventional X-ray diagnostic devices. {sup 99m}Tc has 6 hours half-life, therefore it cannot be stored because it decays into {sup 99}Tc. The parent of {sup 99m}Tc is {sup 99}Mo, which has 66 hours half-life. Consequently, the delivery of {sup 99m}Tc occurs through shipping {sup 99}Mo samples to the medical facilities. The Neutron Source Facility of KIPT is the first ADS in the world operating at non-zero power and allows producing several isotopes for medical applications. The total power of the facility is about 300 kW, including ∼200 kW from fission reactions. The construction of the NSF has been already completed and operations will start during year 2016. After 20 irradiation days, {sup 82}Br, {sup 64}Cu, {sup 165}Dy, {sup 166}Ho, {sup 192}Ir, {sup 194}Ir, {sup 186}Re, {sup 188}Re and {sup 153}Sm have specific activities, larger than 100 MBq/mg without taking into account the self-shielding effect and therefore they are good candidates for production. The self-shielding effect plays an important role for all nuclide parents that have a large microscopic capture cross section. This effect reduces the reaction rate and therefore the specific activity. For instance, the analyses of molybdenum trioxide (MoO{sub 3}) irradiation samples have shown that the self-shielding effect may reduce the specific activity by a factor 1.4. The metallic form of natural molybdenum produces a higher specific activity, relative to the trioxide form. Analyses on the 6-day Ci {sup 99}Mo activity have shown that is possible to perform between 40 to 310 {sup 99m}Tc medical procedures per MoO{sub 3} irradiation week. The number of medical procedures depends on the diagnosed organ and the weight of the patient. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Thermal property characterization of phase change materials in building applications: A systematic review of fundamentals, recent progress, and future directions

Phase change materials (PCMs) can reduce building peak loads and enable demand-responsive thermal energy storage (TES), but their deployment depends on reliable measurement and interpretation of thermal properties across laboratory, intermediate, and application scales. Here, this review systematically examines characterization methods, testing protocols, and recent advances for neat PCMs and PCM composites, emphasizing thermal conductivity, enthalpy-related properties (phase change temperature, latent heat, specific heat), and cycling stability. For thermal conductivity, we compare steady-state and transient techniques and note limitations when phase transition and contact resistance affect measurements. For enthalpy–temperature characterization, we discuss differential scanning calorimetry together with intermediate- and bulk-scale methods, including T-history, heat flow meter testing, and three-layer calorimetry (3LC), to generate application-relevant enthalpy–temperature profiles. Cycling stability is organized into four experimental families: thermoelectric–air, fully thermoelectric, water-bath, and in situ chamber approaches, with attention to separating reversible supercooling from true degradation such as phase segregation. We highlight emerging noncontact diagnostics, including infrared thermography and embedded sensing, for spatially resolved validation and multiscale interpretation. Finally, we review the growing use of AI and machine learning for property prediction, inverse characterization from experimental signals, and real-time state estimation in building-integrated TES. Key needs include harmonized protocols, interlaboratory benchmarking, uncertainty reporting, and metadata-rich datasets to accelerate reproducible PCM qualification for grid-flexible buildings.

AI↗

Applications of high-speed dust injection to magnetic fusion [Slides]

It is now an established fact that a significant amount of dust is produced in magnetic fusion devices due to plasma-wall interactions. Dust inventory must be controlled, in particular for the next-generation steady-state fusion machines like ITER, as it can pose significant safety hazards and degrade performance. Safety concerns are due to tritium retention, dust radioactivity, toxicity, and flammability. Performance concerns include high-Z impurities carried by dust to the fusion core that can reduce plasma temperature and may even induce sudden termination of the plasma. We have recognized that dust transport, dust-plasma interactions in magnetic fusion devices can be effectively studied experimentally by injection of dust with known properties into fusion plasmas. Other applications of injected dust include diagnosis of fusion plasmas and edge localized mode (ELM)'s pacing. In diagnostic applications, dust can be regarded as a source of transient neutrals before complete ionization. ELM's pacing is a promising scheme to prevent disruptions and type I ELM's that can cause catastrophic damage to fusion machines. Different implementation schemes are available depending on applications of dust injection. One of the simplest dust injection schemes is through gravitational acceleration of dust in vacuum. Experiments at Los Alamos and Princeton will be described, both of which use piezoelectric shakers to deliver dust to plasma. In Princeton experiments, spherical particles (40 micron) have been dropped in a systematic and reproducible manner using a computer-controlled piezoelectric bending actuator operating at an acoustic (0,2) resonance. The circular actuator was constructed with a 2.5 mm diameter central hole. At resonance ({approx} 2 kHz) an applied sinusoidal voltage has been used to control the flux of particles exiting the hole. A simple screw throttle located {approx}1mm above the hole has been used to set the magnitude of the flux achieved for a given voltage. Particle fluxes ranging from a few tens of particle per second up to thousands of particles per second have been achieved using this simple device. To achieve higher dust injection speed, another key consideration is how to accelerate dust at controlled amount. In addition to gravity, other possible acceleration mechanisms include electrostatic, electromagnetic, gas-dragged, plasma-dragged, and laser-ablation-based acceleration. Features and limitations of the different acceleration methods will be discussed. We will also describe laboratory experiments on dust acceleration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hypervelocity Impact Test Facility: A gun for hire

An affordable technique has been developed to duplicate the types of impacts observed on spacecraft, including the Shuttle, by use of a certified Hypervelocity Impact Facility (HIF) which propels particulates using capacitor driven electric gun techniques. The fully operational facility provides a flux of particles in the 10-100 micron diameter range with a velocity distribution covering the space debris and interplanetary dust particle environment. HIF measurements of particle size, composition, impact angle and velocity distribution indicate that such parameters can be controlled in a specified, tailored test designed for or by the user. Unique diagnostics enable researchers to fully describe the impact for evaluating the 'targets' under full power or load. Users regularly evaluate space hardware, including solar cells, coatings, and materials, exposing selected portions of space-qualified items to a wide range of impact events and environmental conditions. Benefits include corroboration of data obtained from impact events, flight simulation of designs, accelerated aging of systems, and development of manufacturing techniques.

Johnson, Calvin R.↗

Surgical Clips Assist in the Visualization of the Lumpectomy Cavity in Three-Dimensional Conformal Accelerated Partial-Breast Irradiation

Purpose: To determine to what extent the placement of surgical clips helps delineate the cavity in three-dimensional conformal accelerated partial-breast irradiation. Patients and Methods: Planning CT images of 100 lumpectomy cavities were reviewed in a cohort of 100 consecutive patients. The cavities were determined and categorized by two radiation oncologists according to cavity visualization score criteria and the breast density score. The two physicians first attempted to delineate the lumpectomy cavity without clips and then with clips. Results: In the case of high-density mammary tissue, the breast remodeling done during surgery does not enable the lumpectomy cavity to be sufficiently visualized. The use of surgical clips significantly improved the ability to visualize the lumpectomy cavity, with a 69% rate of concordance between physicians regardless of the breast tissue density. Conclusion: The placement of surgical clips at lumpectomy enables visualization of the lumpectomy cavity and allows upgrading of the cavity visualization score on CT scans obtained for accelerated partial-breast irradiation treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Plasma characterization in a diode with a carbon-fiber cathode

Results of optical and spectroscopic studies of the plasma formation at the surface of two types of carbon-fiber cathodes in a diode powered by an {approx}200 kV accelerating pulse are presented. It was found that during the pulse, generation of the plasma occurs in a form of several millimeter size plasma spots. In the vicinity of the cathode surface the average plasma density and temperature were found to be {approx}3x10{sup 14} cm{sup -3} and {approx}5 eV, respectively, for an electron current density of {approx}22 A/cm{sup 2}. The plasma expansion velocity toward the anode was found to be {approx}1.5x10{sup 6} cm/s during the first 150 ns of the accelerating pulse duration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Large dynamic range beam diagnostics and beam dynamics studies for high current electron LINACs

As described in the previous reports we have been working on an apodized optical system for transverse beam profile measurements by means of imaging. The key issues of LDR imaging is properly managing diffraction effects within the optical system, which is proposed to accomplish by means of amplitude apodization. Shortly before the time of the last progress report we have finished manufacturing of several apodizing elements. We have completed mechanical design of our first apodized imaging system and have built its prototype on an optical bench. Since testing diagnostic equipment with beam is costly and is not always possible due to limited beam availability, it has been our intention to make as much preliminary testing and characterization on a test bench in the laboratory.

43 PARTICLE ACCELERATORS↗

The MTA primary beamline description and performance [Slides]

The Muon Test Area (2003) was initially constructed to develop, test, and verify muon ionization apparatus using the 400-MeV proton beam from the Fermilab Linac. Since muon facilities involve the capture, collection and cooling of ~10 13 muons at a repetition conclusive tests require ~10 13 protons/pulse (full Linac beam): the original concept/request was for a full Linac capability (~10 14 p/sec). The beamline designed for MTA experiments, however, includes specialized insertions for linac beam diagnostics and beam measurements, greatly enhancing the functionality and complexity of the beamline. Installation of the beamline was complete fall, 2008. It represents the only facility in which experiments have direct access to a primary beam.

43 PARTICLE ACCELERATORS↗

LIF Density Measurement Calibration Using a Reference Cell

Flight qualification of ion thrusters typically requires testing on the order of 10,000 hours. Extensive knowledge of wear mechanisms and rates is necessary to establish design confidence prior to long duration tests. Consequently, real-time erosion rate measurements offer the potential both to reduce development costs and to enhance knowledge of the dependency of component wear on operating conditions. Several previous studies have used laser induced fluorescence (LIF) to measure real-time, in situ erosion rates of ion thruster accelerator grids. Those studies provided only relative measurements of the erosion rate. In the present investigation, a molybdenum tube was resistively heated such that the evaporation rate yielded densities within the tube on the order of those expected from accelerator grid erosion. A pulsed UV laser was used to pump the ground state molybdenum at 345.64nm, and the non-resonant fluorescence at 550-nm was collected using a bandpass filter and a photomultiplier tube or intensified CCD array. The sensitivity of the fluorescence was evaluated to determine the limitations of the calibration technique. The suitability of the diagnostic calibration technique was assessed for application to ion engine erosion rate measurements.

Domonkos, Matthew T.↗

Observation of Coherent Optical Transition Radiation in the LCLS Linac

The beam diagnostics in the linac for the Linac Coherent Light Source (LCLS) X-ray FEL project at SLAC includes optical transition radiation (OTR) screens for measurements of transverse and longitudinal beam properties. We report on observations of coherent light emission from the OTR screens (COTR) at visible wavelengths from the uncompressed and compressed electron beam at various stages in the accelerator.

43 PARTICLE ACCELERATORS↗

Microwave Driven Magnetic Plasma Accelerator Studies (CYCLOPS)

A microwave-driven cyclotron resonance plasma acceleration device was investigated using argon, krypton, xenon, and mercury as propellants. Limited ranges of propellant flow rate, input power, and magnetic field strength were used. Over-all efficiencies (including the 65% efficiency of the input polarizer) less than 10% were obtained for specific impulse values between 500 and 1500 sec. Power transfer efficiencies, however, approached 100% of the input power available in the right-hand component of the incident circularly polarized radiation. Beam diagnostics using Langmuir probes, cold gas mapping, r-f mapping and ion energy analyses were performed in conjunction with an engine operating in a pulsed mode. Measurements of transverse electron energies at the position of cyclotron resonant absorption yielded energy values more than an order of magnitude lower than anticipated. The measured electron energies were, however, consistent with the low values of average ion energy measured by retarding potential techniques. The low values of average ion energy were also consistent with the measured thrust values. It is hypothesized that ionization and radiation limit the electron kinetic energy to low-values thus limiting the energy which is finally transferred to the ion. Thermalization by electron-electron collision was also identified as an additional loss mechanism. The use of light alkali metals, which have relatively few low lying energy levels to excite, with the input power to mass ratio selected so as to limit the electron energies to less than the second ionization potential, is suggested. It is concluded, however, that the over-all efficiency for such propellants would be less than 40 per cent.

CYCLOPS PLASMA ACCELERATOR↗

Evidence of electron microbunching in laser-driven modulated downramp injection and prospects for beam-driven implementation

Plasma accelerators can generate high-energy, high-brightness electron beams over centimeter-scale distances, offering novel pathways to compact x-ray free-electron lasers. Generating beams pre-bunched at the desired radiation wavelength would significantly enhance longitudinal coherence and reduce saturation length. Plasma density-modulated downramp injection offers an in-situ way to generate such beams with nanometer-scale bunching. Here we report the first experimental evidence of this mechanism in a laser-driven wakefield accelerator, showing that modulated density downramps generate modulated electron energy spectra absent in unmodulated cases. Particle-in-cell simulations reproduce these observations and reveal bunching factors of 0.05 at 0.4 μm, with a compression factor of approximately 7. Building on this demonstration, we propose a beam-driven implementation for FACET-II to generate multi-GeV beams pre-bunched at hundreds of nanometers wavelength, with sub-micrometer emittance, kiloampere peak current, and sub-percent slice energy spread. Two-stage magnetic compression enables tunable bunching from optical to extreme ultraviolet wavelengths while achieving peak currents exceeding 100 kA. Coherent transition radiation calculations confirm diagnostic feasibility. This approach offers a promising path towards compact, high-energy pre-bunched electron sources for advanced photon science applications.

electron microbunching↗

Coronal Structures in Cool Stars

We have extended our study of the structure of coronas in cool stars to very young stars still accreting from their surrounding disks. In addition we are pursing the connection between coronal X-rays and a powerful diagnostic line in the infrared, the He I 10830Angstrom transition of helium. Highlights of these are summarized below including publications during this reporting period and presentations. Spectroscopy of the infrared He I (lambda10830) line with KECK/NIRSPEC and IRTF/CSHELL and of the ultraviolet C III (lambda977) and O VI (lambda1032) emission with FUSE reveals that the classical T Tauri star TW Hydrae exhibits P Cygni profiles, line asymmetries, and absorption indicative of a continuous, fast (approximately 400 kilometers per second), hot (approximately 300,000 K) accelerating outflow with a mass loss rate approximately 10(exp -11)-10(exp -12) solar mass yr(sup -1) or larger. Spectra of T Tauri N appear consistent with such a wind. The source of the emission and outflow seems restricted to the stars themselves. Although the mass accretion rate is an order of magnitude less for TW Hya than for T Tau, the outflow reaches higher velocities at chromospheric temperatures in TW Hya. Winds from young stellar objects may be substantially hotter and faster than previously thought. The ultraviolet emission lines, when corrected for absorption are broad. Emission associated with the accretion flow and shock is likely to show turbulent broadening. We note that the UV line widths are significantly larger than the X-ray line widths. If the X-rays from TW Hya are generated at the accretion shock, the UV lines may not be directly associated with the shock. On the other hand, studies of X-ray emission in young star clusters, suggest that the strength of the X-ray emission is correlated with stellar rotation, thus casting doubt on an accretion origin for the X-rays. We are beginning to access the infrared spectral region where the He I 108308Angstroms transition occurs. This line is particularly useful as a diagnostic of coronal radiation since it is formed by recombination following photoionization of neutral helium by coronal X-rays. Because the lower level of the transition is metastable, infrared radiation from the stellar photosphere is absorbed which provides a diagnostic of atmospheric dynamics. This transition is useful both in young stars in the T Tauri phase and in active cool star binaries. We will investigate the influence of coronal x-rays on the strength of this transition.

Oliversen, Ronald↗

Recent Advances and New Techniques in Visualization of Ultra-short Relativistic Electron Bunches

Ultrashort electron bunches with rms length of {approx} 1 femtosecond (fs) can be used to generate ultrashort x-ray pulses in FELs that may open up many new regimes in ultrafast sciences. It is also envisioned that ultrashort electron bunches may excite {approx}TeV/m wake fields for plasma wake field acceleration and high field physics studies. Recent success of using 20 pC electron beam to drive an x-ray FEL at LCLS has stimulated world-wide interests in using low charge beam (1 {approx} 20 pC) to generate ultrashort x-ray pulses (0.1 fs {approx} 10 fs) in FELs. Accurate measurement of the length (preferably the temporal profile) of the ultrashort electron bunch is essential for understanding the physics associated with the bunch compression and transportation. However, the shorter and shorter electron bunch greatly challenges the present beam diagnostic methods. In this paper we review the recent advances in the measurement of ultra-short electron bunches. We will focus on several techniques and their variants that provide the state-of-the-art temporal resolution. Methods to further improve the resolution of these techniques and the promise to break the 1 fs time barrier is discussed. We review recent advances in the measurement of ultrashort relativistic electron bunches. We will focus on several techniques and their variants that are capable of breaking the femtosecond time barrier in measurements of ultrashort bunches. Techniques for measuring beam longitudinal phase space as well as the x-ray pulse shape in an x-ray FEL are also discussed.

43 PARTICLE ACCELERATORS↗

BETSI, a new test bench for ion sources optimization at CEA SACLAY

In the framework of several International HPPA projects (such as IFMIF, IPHI, and Spiral2) the CEA handles the design and the developments of several electron cyclotron resonance (ECR) ion sources. For the IFMIF EVEDA demonstrator, a 140 mA cw extracted deuteron beam will be required for high yield of neutron production. For radioactive ion production in the Spiral2 project, several milliamperes of deuterons will be delivered with a permanent magnet source. The optimization of the beam quality at the entrance of the radio frequency quadropole (RFQ) accelerator system triggered the need of a new test bench for ion source optimization and beam qualification. The BETSI ion source test bench will operate up to 50 kV and ignite cw or pulsed hydrogen plasma with a 2.45 GHz magnetron. Great care has already been taken to design electrostatic optics of the extraction system to minimize the emittance growth. Plasma diagnostics will be inserted in the source chamber and several beam diagnostics (emittance and current measurements, beam species analysis) will also be implemented on the low energy beam line transport (LEBT). These diagnostics allow the simultaneous analysis of the beam quality with the plasma parameters of the source. Regional funding request will also be needed to improve the LEBT for space charge compensation measurements. The design of the present and upgraded test bench will be reported as well as the first extracted beam analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Zeeman polarimetry measurement for edge current density determination using Li-beam probe on JT-60U

Zeeman polarimetry system using Li-beam probe has been developed for the edge current density measurement in the JT-60U tokamak, which measures the polarization angle {alpha} (related to the pitch angle of the magnetic field) by means of photoelastic modulators, etalons, and phase sensitive detection using digital lock-in amplifiers with the accuracy in the {alpha} of {Delta}{alpha}{approx}0.1 deg. The diagnostic has 20-channel viewing chords covering the plasma peripheral region of normalized minor radius r/a{approx}0.8-1 with a spatial resolution of up to {approx}1 cm. Li-beam injection with beam current of up to {approx}5 mA has been achieved. A new tuning method of the wavelength for the etalon has been demonstrated, scanning the beam acceleration voltage and keeping a beam current constant during a single shot. The peak wavelength of the etalon is adjusted in the direction to both blue- and redshifts by changing the angle of incidence and increasing the temperature, respectively. Time evolution of the edge current density profile has been determined for the current ramp experiment in the Ohmically heated discharges. In addition, the edge current density profile with the local peak of j{sub ped}{approx}0.15-0.25 MA/m{sup 2} at r/a{approx}0.9 has been identified in the H-mode plasma, which is correlated with large pressure gradient in the pedestal region.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Purification and Concentration of 99 Mo from a UREX raffinate

The medical isotope 99m Tc ( t ½ = 6.0 h) accounts for over 80% of isotopes used in diagnostic nuclear medicine today and is normally derived from its transient equilibrium parent 99 Mo ( t ½ = 66 h). To reduce U.S. dependence on 99 Mo derived from HEU by foreign suppliers, the NNSA/M3 program—under the American Medical Isotope Production Act—has been tasked with facilitating the work of domestic 99 Mo suppliers that do not utilize HEU. Superconducting electron linear accelerators with high-Z converter targets can generate bremsstrahlung photons and neutron fluxes that can induce photonuclear reactions and LEU fission. After sufficient production intervals, targets can be rotated out and processed while another batch is irradiated. The process flow chemistry is shown in Figure 1. The irradiated U 3 O 8 targets are retrieved and dissolved in HNO 3 ; the volatile fission products are expelled and captured during this step. The HNO 3 liquor bearing the uranyl, fission and activation products is injected into the UREX suite of liquid-liquid extraction banks. The uranyl is partitioned in typical fashion using tri-$\textit{n}$-butyl phosphate (TBP) in a hydrocarbon diluent. The raffinate—comprising mainly 99 Mo and fission products—is then injected into the MoLLE (Molybdenum Liquid-Liquid Extraction) flowsheet, where the Mo is selectively extracted by an organophosphorous acid extractant such as di-(2-ethylhexyl phosphoric acid) (HDEHP). Trace amounts of Nb, Zr, Np, I, and Te are co-extracted. The Mo is stripped using acetohydroxamic acid (AHA) and fed onto an anion exchange column. Following a series of hydroxide, HCl, and oxalic acid wash steps, the Mo can be recovered in NaOH/NaCl. A manuscript describing this process chemistry in more detail was recently published.

07 ISOTOPE AND RADIATION SOURCES↗

Extremely rapid radio spikes in flares: A review

Radio spikes of a few to tens of milliseconds of the solar radio emission have recently seen a surge of interest of theoreticians who are fascinated by their high brightness temperature of up to 10 to the 15th power K, their association with hard X-ray bursts, and a possibly very intimate relation to electron acceleration. Their bandwidth and global distribution in frequency were quantitatively measured only recently. This review is intended to emphasize the considerable extend of old and new observational knowledge which is hardly touched upon by theory. The wide range of spike observations is summarized and brought into perspective of recent models. It is concluded that spikes yield a considerable potential for the diagnostics of energetic particles, their origin, and history in astrophysical plasmas.

Benz, A. O.↗