Search NASA⌕ Search

SEARCH · Search NASA

Results for “distribution system optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Fan-beam intensity modulated proton therapy

Purpose: This paper presents a concept for a proton therapy system capable of delivering intensity modulated proton therapy using a fan beam of protons. This system would allow present and future gantry-based facilities to deliver state-of-the-art proton therapy with the greater normal tissue sparing made possible by intensity modulation techniques.Methods: A method for producing a divergent fan beam of protons using a pair of electromagnetic quadrupoles is described and particle transport through the quadrupole doublet is simulated using a commercially available software package. To manipulate the fan beam of protons, a modulation device is developed. This modulator inserts or retracts acrylic leaves of varying thickness from subsections of the fan beam. Each subsection, or beam channel, creates what effectively becomes a beam spot within the fan area. Each channel is able to provide 0–255 mm of range shift for its associated beam spot, or stop the beam and act as an intensity modulator. Results of particle transport simulations through the quadrupole system are incorporated into the MCNPX Monte Carlo transport code along with a model of the range and intensity modulation device. Several design parameters were investigated and optimized, culminating in the ability to create topotherapy treatment plans using distal-edge tracking on both phantom and patient datasets.Results: Beam transport calculations show that a pair of electromagnetic quadrupoles can be used to create a divergent fan beam of 200 MeV protons over a distance of 2.1 m. The quadrupole lengths were 30 and 48 cm, respectively, with transverse field gradients less than 20 T/m, which is within the range of water-cooled magnets for the quadrupole radii used. MCNPX simulations of topotherapy treatment plans suggest that, when using the distal edge tracking delivery method, many delivery angles are more important than insisting on narrow beam channel widths in order to obtain conformal target coverage. Overall, the sharp distal falloff of a proton depth-dose distribution was found to provide sufficient control over the dose distribution to meet objectives, even with coarse lateral resolution and channel widths as large as 2 cm. Treatment plans on both phantom and patient data show that dose conformity suffers when treatments are delivered from less than approximately ten angles. Treatment time for a sample prostate delivery is estimated to be on the order of 10 min, and neutron production is estimated to be comparable to that found for existing collimated systems.Conclusions: Fan beam proton therapy is a method of delivering intensity modulated proton therapy which may be employed as an alternative to magnetic scanning systems. A fan beam of protons can be created by a set of quadrupole magnets and modified by a dual-purpose range and intensity modulator. This can be used to deliver inversely planned treatments, with spot intensities optimized to meet user defined dose objectives. Additionally, the ability of a fan beam delivery system to effectively treat multiple beam spots simultaneously may provide advantages as compared to spot scanning deliveries.

61 RADIATION PROTECTION AND DOSIMETRY↗

Nuclear hybrid energy infrastructure

The nuclear hybrid energy concept is becoming a reality for the US energy infrastructure where combinations of the various potential energy sources (nuclear, wind, solar, biomass, and so on) are integrated in a hybrid energy system. This paper focuses on challenges facing a hybrid system with a Small Modular Reactor at its core. The core of the paper will discuss efforts required to develop supervisory control center that collects data, supports decision-making, and serves as an information hub for supervisory control center. Such a center will also be a model for integrating future technologies and controls. In addition, advanced operations research, thermal cycle analysis, energy conversion analysis, control engineering, and human factors engineering will be part of the supervisory control center. Nuclear hybrid energy infrastructure would allow operators to optimize the cost of energy production by providing appropriate means of integrating different energy sources. The data needs to be stored, processed, analyzed, trended, and projected at right time to right operator to integrate different energy sources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

GPU-resident sparse direct linear solvers for alternating current optimal power flow analysis

Integrating renewable resources within the transmission grid at a wide scale poses significant challenges for economic dispatch as it requires analysis with more optimization parameters, constraints, and sources of uncertainty. This motivates the investigation of more efficient computational methods, especially those for solving the underlying linear systems, which typically take more than half of the overall computation time. In this paper, we present our work on sparse linear solvers that take advantage of hardware accelerators, such as graphical processing units (GPUs), and improve the overall performance when used within economic dispatch computations. We treat the problems as sparse, which allows for faster execution but also makes the implementation of numerical methods more challenging. We present the first GPU-native sparse direct solver that can execute on both AMD and NVIDIA GPUs. We demonstrate significant performance improvements when using high-performance linear solvers within alternating current optimal power flow (ACOPF) analysis. Furthermore, we demonstrate the feasibility of getting significant performance improvements by executing the entire computation on GPU-based hardware. Finally, we identify outstanding research issues and opportunities for even better utilization of heterogeneous systems, including those equipped with GPUs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Integrated Paradigm for the Management of Delivery Risk in Electricity Markets: From Batteries to Insurance and Beyond

If power systems transition to integrate higher amounts of variable renewable energy sources, storage technologies, and distributed energy resources (DERs), new risk management frameworks are necessary to ensure cost-effective and reliable power system operations. Projects funded by the Advanced Research Projects Agency-Energy (ARPA-E) Performance-based Energy Resource Feedback, Optimization, and Risk Management (PERFORM) program aim to contribute new risk management frameworks by developing methods to quantify and manage risk at grid asset and system levels. The National Renewable Energy Laboratory (NREL) led a PERFORM project in collaboration with the Johns Hopkins University, the Electric Power Research Institute (EPRI), kWh Analytics, Packetized Energy, and Imperial Consultants (ICON). The project addressed two challenges related to risk management in electricity markets: managing net load imbalances and flexibility from DERs. This final technical report presents a list of project accomplishments, activities, and outputs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessing hydrogen supply chains: An integrated review of leakage and energy efficiency studies

This paper examines hydrogen leakage and efficiency across the supply chain for liquid, gaseous, and mixed hydrogen systems. These factors are crucial for assessing hydrogen's role in mitigating emissions and facilitating a clean energy transition. Drawing on a comprehensive review of existing literature and model-based analysis, the study compiles leakage rates and efficiency metrics at each stage of the supply chain: production, storage, transmission, distribution, and end-use. These data inform system scenarios that estimate the impact of leakage on overall performance and climate benefits. The analysis also identifies persistent data gaps, particularly for liquid and mixed system configurations, and outlines priorities for future research. A comparison of hydrogen system types shows that gaseous pathways generally achieve the highest efficiencies (28 %–39 %) and the lowest leakage rates (∼4.5 %) across the supply chain. Liquid hydrogen systems, while favorable for long-distance and high-volume transport due to their higher energy density, exhibit lower efficiency (∼28 %) and a greater leakage potential (∼12 %). Mixed systems, which combine gaseous and liquid elements (e.g., pipeline transmission followed by liquefaction and truck distribution), show compounded energy losses and moderate-to-high leakage rates (6.8 %–9.4 %), highlighting trade-offs associated with added system complexity. The study highlights opportunities for technological advancements, including optimizing liquefaction, enhancing insulation for storage and transportation, and refining refueling equipment. These improvements are crucial for maximizing the climate benefits of hydrogen. The results offer actionable insights for researchers, industry, and policymakers working to develop low-leakage, high-efficiency hydrogen infrastructure.

08 HYDROGEN↗

Chromatic-free spatially resolved optical emission spectroscopy diagnostics for microplasma

A chromatic-free spatially resolved diagnostic system for microplasma measurement is proposed and demonstrated, which consists of an optical chromatic-free microscope mirror system, an electron multiplying charge coupled device (EMCCD), and bandpass filters. The diagnostic system free of chromatic aberrations with a spatial resolution of about 6 {mu}m is achieved. The factors that limit the resolution of this diagnostic system have been analyzed, which are optical diffraction, the pixel size of the EMCCD, and the thickness of the microplasma. In this paper, the optimal condition for achieving a maximum resolution power has been analyzed. With this diagnostic system, we revealed the spatial nonuniformity of a microwave atmospheric-pressure argon microplasma. Furthermore, the spatial distribution of the time-averaged effective electron temperature has been estimated from the intensity distributions of 750.4 and 415.8 nm emissions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Visible spectroscopy diagnostics for tungsten source assessment in the WEST tokamak: First measurements

The present work concerns the measurements obtained with the Tungsten (W) Environment in Steady-state Tokamak (WEST) visible spectroscopy system during the first experimental campaign. This system has been developed in the framework of the WEST project that equipped the existing Tore Supra device with a tungsten divertor in order to test actively cooled tungsten Plasma Facing Components (PFC) in view of preparing for ITER operation. The goal of this diagnostic is to measure the PFC sources and the deuterium recycling with spectral, spatial, and temporal resolution adapted to the predicted power deposition profiles on the objects observed. Three kinds of PFCs are monitored: the Ion Cyclotron Resonance Heating (ICRH) antenna and Low Hybrid Current Drive (LHCD) launcher W limiters; one of the 6 W inner bumpers; and the upper and lower W divertors. Large-aperture in-vessel actively cooled optical systems (f-number ~ 3) were installed for each view and connected to optical fibres. A total of 240 optical fibers can be distributed on various detection systems including a fast response-time, multi-channel, filtered photodetector-based “Filterscope” system, developed by Oak Ridge National Laboratory (USA) as well as grating spectrometers optimized for multi-sightline analysis. The first WEST experimental campaign conducted in 2017 has been dedicated to plasma start-up development during which the visible spectroscopy system has provided crucial information related to the impurity content first and then impurity sources. The diagnostic setup for that first experimental campaign was limited to the inner bumper and outer limiters but was sufficient to demonstrate that the optical setup was in accordance with the specifications. The radiance calibration procedure allowed us to estimate fluxes from the main limiter of about 8 × 10 18 atoms/(s m 2 ) and to show a first W source radial profile along the outboard limiter.

Meyer, O.↗

Coordination of Energy Storage and Distributed Generation for Voltage Control and Peak-valley Filling

The increasing penetration of distributed energy resources (DERs) in distribution network (DN) poses challenges on voltage control. In addition, the growing integration of DERs also reshapes the traditional load profile. To comprehensively address the voltage control and peak-valley filling in DN, this paper proposes a model predictive control (MPC) based optimization framework. The proposed method can achieve coordinated voltage control and peak-valley filling by adjusting the reactive power output from distributed generations (DGs) and the charging/discharging of energy storage systems (ESS). The performance of the proposed method is demonstrated by simulations on a modified IEEE-123 bus system.

Zhang, Zhengfa [University of Tennessee, Knoxville↗

SU-F-T-149: Development of the Monte Carlo Simulation Platform Using Geant4 for Designing Heavy Ion Therapy Beam Nozzle

Purpose: The significant issue of particle therapy such as proton and carbon ion was a accurate dose delivery from beam line to patient. For designing the complex delivery system, Monte Carlo simulation can be used for the simulation of various physical interaction in scatters and filters. In this report, we present the development of Monte Carlo simulation platform to help design the prototype of particle therapy nozzle and performed the Monte Carlo simulation using Geant4. Also we show the prototype design of particle therapy beam nozzle for Korea Heavy Ion Medical Accelerator (KHIMA) project in Korea Institute of Radiological and Medical Science(KIRAMS) at Republic of Korea. Methods: We developed a simulation platform for particle therapy beam nozzle using Geant4. In this platform, the prototype nozzle design of Scanning system for carbon was simply designed. For comparison with theoretic beam optics, the beam profile on lateral distribution at isocenter is compared with Mont Carlo simulation result. From the result of this analysis, we can expected the beam spot property of KHIMA system and implement the spot size optimization for our spot scanning system. Results: For characteristics study of scanning system, various combination of the spot size from accerlator with ridge filter and beam monitor was tested as simple design for KHIMA dose delivery system. Conclusion: In this report, we presented the part of simulation platform and the characteristics study. This study is now on-going in order to develop the simulation platform including the beam nozzle and the dose verification tool with treatment planning system. This will be presented as soon as it is become available.

60 APPLIED LIFE SCIENCES↗

SU-G-201-11: Exploring the Upper Limits of Dose Sculpting Capacity of the Novel Direction Modulated Brachytherapy (DMBT) Tandem Applicator

Purpose: To explore and quantify the upper limits in dose sculpting capacity of the novel direction modulated brachytherapy (DMBT) tandem applicator compared with conventional tandem design for {sup 192}Ir-based HDR planning. Methods: The proposed DMBT tandem applicator is designed for image-guided adaptive brachytherapy (IGABT), especially MRI, of cervical cancer. It has 6 peripheral holes of 1.3-mm width, grooved along a 5.4-mm diameter nonmagnetic tungsten alloy rod of density 18.0 g/cc, capable of generating directional dose profiles – leading to enhanced dose sculpting capacity through inverse planning. The external dimensions are identical to that of conventional tandem design to ensure clinical compatibility. To explore the expansive dose sculpting capacity, we constructed a hypothetical circular target with 20-mm radius and positioned the DMBT and conventional tandems at the center. We then incrementally shifted the positions laterally away from the center of up to 15 mm, at 1-mm steps. The in-house coded gradient projection-based inverse planning system was then used to generate inverse optimized plans ensuring identical V100=100% coverage. Conformity index (CI) was calculated for all plans. Results: Overall, the DMBT tandem generates more conformal dose distributions than conventional tandem for all lateral positional shifts of 0-15 mm (CI=0.91–0.52 and 0.99–0.34, respectively), with an exception at the central position due to the ideal circular dose distribution, generated by the {sup 192}Ir, fitting tightly around the circular target (CI = 0.91 and 0.99, respectively). The DMBT tandem is able to generate dose conformity of CI>0.8 at up to 6-mm positional shift while the conventional tandem violates this past 2-mm shift. Also, the CI ratio (=DMBT/conv.) increases rapidly until about 8 mm and then stabilizes beyond. Conclusion: A substantial enhancement in the dose sculpting capacity has been demonstrated for the novel DMBT tandem applicator. While further studies are warranted, the concept is promising for potential clinical translation.

60 APPLIED LIFE SCIENCES↗

HEMS: Home Energy Management System [SWR-15-12] - Stochastic Optimal Scheduling of Residential Appliances with Renewable Energy Sources

The HEMS algorithm schedules residential appliance operation to minimize the weighted sum of occupant discomfort, total energy cost, peak electricity consumption and carbon footprint, weighted according to occupant preferences. A centralized mixed integer linear programming (MILP) based optimization approach is taken, with the HEMS managing all appliances directly, following a Model Predictive Control (MPC) methodology which determines the optimal schedule over the user-specified scheduling horizon and repeats the optimization at configurable time intervals. The HEMS is developed on the General Algebraic Modeling System (GAMS) using the MILP solver. This system is able to effectively deal with the stochasticity in the distributed system by utilizing Monte Carlo simulation where uncertainties in future electricity price, outdoor temperature, water usage, solar and wind generation can be accounted for. The HEMS controls the operation of the heating, ventilation and air conditioning (HVAC) system, water heater, refrigerator, residential batteries, electric vehicles, standalone micro combined heat and power (CHP) generator, dishwasher, washer/dryer, pool pumps, and lighting.

Pratt, Annabelle↗

Cross-scale Efficient Tensor Contractions for Coupled Cluster Computations Through Multiple Programming Model Backends

Coupled-cluster methods provide highly accurate models of molecular structure by explicit numerical calculation of tensors representing the correlation between electrons. These calculations are dominated by a sequence of tensor contractions, motivating the development of numerical libraries for such operations. While based on matrix-matrix multiplication, these libraries are specialized to exploit symmetries in the molecular structure and in electronic interactions, and thus reduce the size of the tensor representation and the complexity of contractions. The resulting algorithms are irregular and their parallelization has been previously achieved via the use of dynamic scheduling or specialized data decompositions. We introduce our efforts to extend the Libtensor framework to work in the distributed memory environment in a scalable and energy efficient manner. We achieve up to 240 speedup compared with the best optimized shared memory implementation. We attain scalability to hundreds of thousands of compute cores on three distributed-memory architectures, (Cray XC30&XC40, BlueGene/Q), and on a heterogeneous GPU-CPU system (Cray XK7). As the bottlenecks shift from being compute-bound DGEMM's to communication-bound collectives as the size of the molecular system scales, we adopt two radically different parallelization approaches for handling load-imbalance. Nevertheless, we preserve a uni ed interface to both programming models to maintain the productivity of computational quantum chemists.

74 ATOMIC AND MOLECULAR PHYSICS↗

Microgrid Energy Management System Integration with Advanced Distribution Management System

The Integrated Distribution Management System (IDMS) project was initiated to demonstrate the interactive operation of microgrid systems and the distribution systems with which they interconnect. The key technologies for this are the microgrid management system and the utility distribution management system. The IDMS project successfully demonstrated that a utility’s advanced distribution management system/distributed energy resources management system (ADMS/DERMS) could effectively manage microgrids to provide visibility and control functionalities as well as use the microgrid as a dispatchable resource to support the utility grid. The DERMS accomplishes this by determining active and reactive power needs at the point of common coupling (PCC) using advanced applications like volt/VAR watt optimization (VVWO) and load relief (LR) with the underlying core applications state estimation (SE) and load flow (LF). The ADMS/DERMS can use the microgrid as a resource to resolve and prevent violations in the grid and to optimize the operational working state of the grid. The IDMS project demonstrated that a utility-operated ADMS with embedded DERMS functionality can flexibly manage a variety of microgrids and other aggregated distributed energy resources (DER) in concert with the wider distribution grid. Microgrids can provide grid services in any number of different ways to meet the operational needs of the distribution utility. The manner of aggregation — microgrid or virtual power plant — is not necessarily relevant to the utility as long as the grid services from the aggregated DER are available and can be managed by its ADMS/DERMS for the stability and reliability of the grid. The IDMS project demonstrated this integrated ADMS concept by combining hardware/software-in-the-loop testing with commercial products from different vendors and a utility’s network model. The project integrated the Schneider Electric EcoStruxure™ ADMS with DERMS with the Schweitzer Engineering Laboratories (SEL) POWERMAX ® Microgrid Control System, and the simulated resources with energy company PECO’s model of a utility-owned microgrid, establishing an operational relationship in which the utility manages the operational functionality of a microgrid at the PCC and that provides the utility with the capability to control the comprehensive power system, inclusive of the macrogrid and microgrid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of the Effects of a Flexible Ramping Ancillary Service Product on Power System Operations: Preprint

The recent increased interest in utilizing variable generation (VG) resources such as wind and solar in power systems has motivated investigations into new operating procedures. Although these resources provide desirable value to a system (e.g., no fuel costs or emissions), interconnecting them provides unique challenges. Their variable, non-controllable nature in particular requires significant attention, because it directly results in increased power system variability and uncertainty. One way to handle this is via new operating reserve schemes. Operating reserves provide upward and downward generation and ramping capacity to counteract uncertainty and variability prior to their realization. For instance, uncertainty and variability in real-time dispatch can be accounted for in the hour-ahead unit commitment. New operating reserve methodologies that specifically account for the increased variability and uncertainty caused by VG are currently being investigated and developed by academia and industry. This paper examines one method inspired by the new operating reserve product being proposed by the California Independent System Operator. The method is based on examining the potential ramping requirements at any given time and enforcing those requirements via a reserve demand curve in the market-clearing optimization as an additional ancillary service product.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Intelligent Monitoring System for Real-time Geologic Storage, Optimization, and Reservoir Management

The objective of the subtask was to develop a near-real-time monitoring system for seismic data at the Decatur, IL, geologic carbon sequestration (GCS) site and specifically include fiber-optic cable derived distributed acoustic signal (DAS) data in the process. Owing to the large volumes of data, we opted to utilize existing deep borehole conventional seismic sensors for detection and pull DAS and shallow borehole seismic data once a detection has been made. Unfortunately, the horizontal fiber-optic cables did not yield microseismic signals for use in locating events near the GCS site. Various stacking and filtering approaches were tested without any coherent detection becoming apparent. We attribute the insensitivity to local microseismic events to a lack of coupling in downhole, vertical cable and the non-ideal alignment of the horizontal fiber-optic cable to the vertically polarized seismic energy. Despite the inability to detect and utilize the DAS data from the fiber-optic cables, we developed a general processing framework that enables easy adaptation for future deployment of fiber-optic cables with better suited alignment at Decatur or elsewhere.

Kaven, J. Ole↗

Decision support for integrated water-energy planning.

Currently, electrical power generation uses about 140 billion gallons of water per day accounting for over 39% of all freshwater withdrawals thus competing with irrigated agriculture as the leading user of water. Coupled to this water use is the required pumping, conveyance, treatment, storage and distribution of the water which requires on average 3% of all electric power generated. While water and energy use are tightly coupled, planning and management of these fundamental resources are rarely treated in an integrated fashion. Toward this need, a decision support framework has been developed that targets the shared needs of energy and water producers, resource managers, regulators, and decision makers at the federal, state and local levels. The framework integrates analysis and optimization capabilities to identify trade-offs, and 'best' alternatives among a broad list of energy/water options and objectives. The decision support framework is formulated in a modular architecture, facilitating tailored analyses over different geographical regions and scales (e.g., national, state, county, watershed, NERC region). An interactive interface allows direct control of the model and access to real-time results displayed as charts, graphs and maps. Ultimately, this open and interactive modeling framework provides a tool for evaluating competing policy and technical options relevant to the energy-water nexus.

13 HYDRO ENERGY↗

Advanced modeling of $\mathrm{DER}$s and $\mathrm{UPFC}$ devices with Sparse Tableau Formulation for $\mathrm{ACOPF}$

Distributed energy resources (DERs) are projected to be significant contributors in electric power grid modernization efforts. Yet many distribution and transmission system operators are concerned about potential reliability and security impacts of high penetration of DERs, and cite the need of greater visibility and controllability of decision variables associated with these DERs. Tractable modeling of DERs in AC optimal power flow (ACOPF) is one of the barriers to their integration into the existing operation, planning and market paradigm. Similarly, as more intermittent renewable resources are deployed, power flow control becomes more valuable, and accurate representation of Flexible AC Transmission System (FACTS) devices in ACOPF will likely grow in importance. Here this paper focuses on the detailed representation of substations with the high penetration of DERs, and on the Unified Power Flow Controller (UPFC) FACTS devices, in OPF. To this end, a novel Sparse Tableau Formulation (STF) for ACOPF is used to accurately model such features as substation reconfiguration to accommodate DERs, and to represent decision variables appropriate to the voltage source converters within UPFCs. Numerical studies are provided to demonstrate the impacts of detailed DER and UPFC representations on optimal operation, and the computational efficiency.

42 ENGINEERING↗