Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,387 records · Page 77

Electrostatic Return of Contaminants

A Model has been developed capable of calculating the electrostatic return of spacecraft-emitted molecules that are ionized and attracted back to the spacecraft by the spacecraft electric potential on its surfaces. The return of ionized contaminant molecules to charged spacecraft surfaces is very important to all altitudes. It is especially important at geosynchronous and interplanetary environments, since it may be the only mechanism by which contaminants can degrade a surface. This model is applicable to all altitudes and spacecraft geometries. In addition to results of the model will be completed to cover a wide range of potential space systems.

Rantanen, R.↗

Demonstration of Wide Area Radiological Decontamination and Mitigation Technologies for Building Structures and Vehicles - 16508

Researchers at the U.S. Environmental Protection Agency in collaboration with the Department of Homeland Security conducted the 'Wide-Area Urban Radiological Contaminant, Mitigation, and Clean-Up Technology Demonstration' in Columbus, Ohio on June 22-25, 2015. EPA's National Homeland Security Research Center (NHSRC) demonstrated five wide-area radiological decontamination technologies (including strippable coatings, gels, and chemical foam technologies) on an urban building. Decontamination technologies were applied to remove the contaminants from the building's surfaces by physical, chemical, or other methods, which in practice could reduce radiation exposure level. In addition, NHSRC teamed with the Department of Homeland Security (DHS) to demonstrate several radiological contaminant mitigation technologies including building and vehicle wash technologies, as well as several approaches to contain wash water and radioactive particles. 'Radiological contaminant mitigation' technologies are measures taken to reduce adverse impacts of radiological contamination on people and the environment, and facilitate such purposes as restoration of first responder services and critical infrastructure. Radiological contaminant mitigation technologies are designed for containing and removing radiological contamination on the surface in the first hours or days following a radiological event (early phase response). Such technologies include 'radiological particle containment', which is design to prevent the spread of particles which might result from vehicle or foot traffic. Radiological particle containment technologies are applicable for early phase response to contain the radionuclides and to reduce radiation dose to responders and the public. Mitigation also includes 'gross decontamination' technologies, which perform a type of decontamination that is conducted with the goal of reducing contamination levels. This reduction may not meet final cleanup levels, but may be useful to mitigate some public hazard or contain contamination. The purpose of the demonstrations was to educate potential end-users and stakeholders of this technology about a 'Toolbox of Options' for radiological decontamination, as well as radiological contaminant mitigation. Both demonstrations were conducted using a 75-year old brick building and the surrounding area (including parking lots) in Columbus, OH. No radioactive contaminants were applied during either demonstration, as the objective was to duplicate and implement realistic operational conditions for these technologies. Surrogate contaminants such as particle tracers were used in several demonstrations. The decontamination technologies were used in a scaled-up setting with application to the building. Contaminant mitigation technologies were demonstrated on the building as well as on vehicles. Example technology application techniques/accessories included an articulating boom lift, repelling boatswain chair, stand-alone surface material structures, high-volume foam applicators, fire truck foam applicator, a vehicle wash tent for vehicles, particle tracers to simulate radiological contaminants, and high- and low-technology liquid containment approaches. Results and stakeholder observations from the demonstration are now publically in a report entitled 'Technical Report for the Demonstration of Radiological Decontamination and Mitigation Technologies for Building Structures and Vehicles' available at http://www.epa.gov/hsresearch Example information that was obtained included decontamination rate, contaminant mitigation and containment capacity, user friendliness of each technology, the required utilities (electric, water, etc.) for each technology, skill of worker required, and the cost. The condition (color, texture, integrity, etc.) of each building material present on the structure along with all structural components such as gutters, windows, doors, etc. were carefully examined and documented. All demonstrations were open to individuals, organizations, and local, state, federal, tribal, and international governments who may be involved with implementing or planning radiological incident response. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Use of XPS to Quantify Thickness of Coatings on Nanoparticles

XPS and other surface sensitive methods are being increasingly used to extract quantitative information about organic and inorganic coatings and contamination on nanoparticles. The extraction of coating thickness information requires combining known information about particle diameter from other measurements, such as electron microscopy, combined with a model that includes the physical processes associated with XPS, including electron path lengths, and particle geometry. Advantages of using XPS include the sensitivity to very thin coatings (or surface contamination) and the abillity to extract important information about organic layers. Single particle information from electron microsocpy combined XPS sensitivity to determine an average coating structure and composition make a powerful combination for nanoparticle anlaysis.

Environmental Molecular Sciences Laboratory↗

A Permeable Active Amendment Concrete (Paac) For Contaminant Remediation and Erosion Control

The final project report for SEED SERDP ER - 2134 describes the development of permeable active amendment concrete (PAAC), which was evaluated through four tasks: 1) development of PAAC; 2) assessment of PAAC for contaminant removal; 3) evaluation of promising PAAC formulations for potential environmental impacts; and 4) assessment of the hydraulic, physical, and structural properties of PAAC. Conventional permeable concrete (often referred to as pervious concrete) is concrete with high porosity as a result of an extensive and interconnected void content. It is made from carefully controlled amounts of water and cementitious materials used to create a paste that forms a coating around aggregate particles. The mixture has a substantial void content (e.g., 15% - 25%) that results in a highly permeable structure that drains quickly. In PAAC, the aggregate material is partly replaced by chemically-active amendments that precipitate or adsorb contaminants in water that flows through the concrete interstices. PAAC combines the relatively high structural strength, ample void space, and water permeability of pervious concrete with the contaminant sequestration ability of chemically-active amendments to produce a new material with superior durability and ability to control contaminant mobility. The high surface area provided by the concrete interstices in PAAC provides significant opportunity for contaminants to react with the amendments incorporated into the concrete matrix. PAAC has the potential to immobilize a large variety of organic and inorganic contaminants by incorporating different active sequestering agents including phosphate materials (rock phosphate), organoclays, zeolite, and lime individually or in combinations.

36 MATERIALS SCIENCE↗

Visual, Optical and Replica Inspections: Surface Preparation of 650 MHz NB Cavity for PIP-II Linac

Surface preparation of niobium superconducting RF cavities is a critical step for achieving good RF performance under the superconducting state. Surface defect, roughness, and contamination affect the accelerating gradient and quality factor of the cavities. We report surface inspection methods used to control the surface processing of 650 MHz cavities designated for the pre-production and prototype cryomodules for PIP-II linac. The cavity surface was routinely inspected visually, with an optical camera, and by microscopic scanning of surface replicas. This article covers details on the surface inspection methods and surface polishing process used to repair the surface.

43 PARTICLE ACCELERATORS↗

Calendar Year 2010 Groundwater Monitoring Report, U.S. Department Of Energy Y-12 National Security Complex, Oak Ridge, Tennessee

This report contains the groundwater and surface water monitoring data that were obtained during calendar year (CY) 2010 at the U.S. Department of Energy (DOE) Y-12 National Security Complex (hereafter referenced as Y-12) on the DOE Oak Ridge Reservation (ORR) in Oak Ridge, Tennessee. The CY 2010 monitoring data were obtained from wells, springs, and surface water sampling locations in three hydrogeologic regimes at Y-12 (Figure A.1). The Bear Creek Hydrogeologic Regime (Bear Creek Regime) encompasses a section of Bear Creek Valley (BCV) between the west end of Y-12 and the west end of the Bear Creek Watershed (directions are in reference to the Y-12 grid system). The Upper East Fork Poplar Creek Hydrogeologic Regime (East Fork Regime) encompasses the Y-12 industrial facilities and support structures in BCV. The Chestnut Ridge Hydrogeologic Regime (Chestnut Ridge Regime) encompasses a section of Chestnut Ridge directly south of Y-12. Section 2 of this report provides background information pertinent to groundwater and surface water quality monitoring in each hydrogeologic regime, including the topography and bedrock geology, surface water drainage, groundwater system, and extent of groundwater contamination. The CY 2010 groundwater and surface water monitoring data in this report were obtained from sampling and analysis activities implemented under the Y-12 Groundwater Protection Program (GWPP) managed by Babcock & Wilcox Technical Services Y-12, LLC (B&W Y-12) and from sampling and analysis activities implemented under several monitoring programs managed by Bechtel Jacobs Company LLC (BJC). Cooperative implementation of the monitoring programs directed by the Y-12 GWPP and BJC (i.e., coordinating sample collection and sharing data) ensures that the CY 2010 monitoring results fulfill requirements of all the applicable monitoring drivers with no duplication of sampling and analysis efforts. Section 3 of this report contains a summary of information regarding the groundwater and surface water sampling and analysis activities implemented under the Y-12 GWPP including sampling locations and frequency; quality assurance (QA)/quality control (QC) sampling; sample collection and handling; field measurements and laboratory analytes; data management and data quality objective (DQO) evaluation; and groundwater elevation monitoring. However, this report does not include equivalent QA/QC or DQO evaluation information regarding the groundwater and surface water sampling and analysis activities associated with the monitoring programs implemented by BJC. Such details are deferred to the respective programmatic plans and reports issued by BJC (see Section 3.0). Collectively, the groundwater and surface water monitoring data obtained during CY 2010 by the Y-12 GWPP and BJC address DOE Order 450.1A (Environmental Protection Program) requirements for monitoring groundwater and surface water quality in areas: (1) which are, or could be, affected by operations at Y-12 (surveillance monitoring); and (2) where contaminants from Y-12 are most likely to migrate beyond the boundaries of the ORR (exit pathway/perimeter monitoring). Section 4 of this report presents a summary evaluation of the monitoring data with regard to the respective objectives of surveillance monitoring and exit pathway/perimeter monitoring, based on the analytical results for the principal groundwater contaminants at Y-12: nitrate, uranium, volatile organic compounds (VOCs), gross alpha activity, and gross beta activity. Section 5 of this report summarizes the most pertinent findings regarding the principal contaminants, along with recommendations proposed for ongoing groundwater and surface water quality monitoring performed under the Y-12 GWPP.

54 ENVIRONMENTAL SCIENCES↗

25 years of environmental remediation in the general separations area of the Savannah river site: lessons learned about what worked and what did not work in soil and groundwater cleanup - 15270

The Savannah River Site, which is owned and administered by the US Department of Energy, covers approximately 900 square kilometers. The General Separation Area is located in the center of the site and includes: radioactive material chemical separations facilities, radioactive waste tank farms, radioactive seepage basins, and the radioactive waste burial grounds. Radioactive wastes were disposed in the General Separation Area from the mid-1950's through the mid-1990's. Operations at the F Canyon began in 1954 and at H Canyon began in 1955. Waste water disposition to the F and H Seepage Basins began soon after operations started in the canyons. The Old Radioactive Waste Burial Ground began operations in 1952 to manage solid waste that could be radioactive from all the site operations, and ceased receiving waste in 1972. The Mixed Waste Management Facility and Low Level Radioactive Waste Disposal Facility received radioactive solid waste from 1969 until 1995. Environmental legislation enacted in the 1970's through 1990's led to changes in waste management and environmental cleanup practices. The US Congress passed the Clean Air Act in 1970 and the Clean Water Act in 1972; the Resource Conservation and Recovery Act was enacted in 1976; the Comprehensive Environmental Response Compensation, and Liability Act was enacted by Congress in 1980; and the Federal Facilities Compliance Act was signed into law in 1992. Environmental remediation at the Savannah River Site essentially began with a 1987 Settlement Agreement between the Savannah River Site and the State of South Carolina. The site manages several of the larger groundwater remedial activities under the Resource Conservation and Recovery Act for facilities recognized early on as environmental problems. All subsequent remediation projects are managed under a tri-party agreement (Department of Energy, Environmental Protection Agency, and South Carolina Department of Health and Environmental Control) through the Federal Facilities Agreement. Environmental remediation activities during the past 25 years have stabilized and capped seepage basins as well as consolidated and capped waste units and burial grounds in the General Separation Area. Groundwater activities include: pump and treat systems in the groundwater, installation of deep subsurface barrier systems to manage groundwater flow, in situ chemical treatments in the groundwater, and captured contaminated groundwater discharges at the surface for management in a forest irrigation system. Concentrations of contaminants in the aquifers beneath the General Separation Area and in surface water streams in the General Separation Area have decreased over the past 25 years. Closure of 65 waste sites and 4 Resource Conservation and Recovery Act facilities has been successfully accomplished. Environmental clean-up has progressed to the stage where most of the work involves monitoring, optimization, and maintenance of existing remedial systems. Many lessons have been learned in the process of remediating the General Separations Area. Geo-textile covers outperform low permeability clay caps, especially with respect to the amount of repairs required to upkeep the drainage layers as the caps age. Passive and enhanced natural processes to address contamination are much more cost effective than pump and treat systems. Forest irrigation can be very effective in water management situations with non-accumulative contaminants such as tritium and volatile organic contaminants. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The influence of man in space observations

The paper evaluates the Skylab missions from the viewpoint of to what extent the presence of men may have been a detriment to scientific observations, either through their movements or through contamination of the spacecraft and instruments. The stability of the instrument canister within the Apollo Telescope Mount was secured by the Experiment Pointing Control System. Angular stability was specified to be within plus or minus 2.5 arc seconds, and was found to be less than 2 arc seconds during normal crew activity. No astronomical observations were reported as being degraded by crew movements. Instrumentation was installed to measure rates of contaminant particle deposition on optical surfaces. Clouds were formed from particles originating in outgassing from vehicle surface materials and from vent apertures. The Coronograph Contamination Measurement Instrument was used to measure the brightness of the induced cloud surrounding Skylab. Preliminary analysis shows no significant degradation of photographic data attributable to contamination.

Hanes, T. E.↗

Sample processing approach for detection of ricin in surface samples

With several ricin contamination incidents reported over the past decade, rapid and accurate methods are needed for environmental sample analysis, especially after decontamination. A sample processing method was developed for common surface sampling devices to improve the limit of detection and avoid false negative/positive results for ricin analysis. Potential assay interferents from the sample matrix (bleach residue, sample material, wetting buffer), including reference dust, were tested using a Time-Resolved Fluorescence (TRF) immunoassay. Test results suggested that the sample matrix did not cause the elevated background fluorescence sometimes observed when analyzing post-bleach decontamination samples from ricin incidents. Furthermore, sample particulates (80 mg/mL Arizona Test Dust) did not enhance background fluorescence or interfere with ricin detection by TRF. These results suggested that high background fluorescence in this immunoassay could be due to labeled antibody quality and/or quantity issues. Centrifugal ultrafiltration devices were evaluated for ricin concentration as a part of sample processing. Up to 30-fold concentration of ricin was observed by the devices, which serve to remove soluble interferents and could function as the front-end sample processing step to other ricin analytical methods. Here, the procedure has the potential to be used with a broader range of environmental sample types and with other potential interferences and to be followed by other ricin analytical methods, although additional verification studies would be required.

54 ENVIRONMENTAL SCIENCES↗

Vertical Transport of Water/Contaminant Due to Intermittent Water Influx on the Ground Surface of Vadose Zone - 20088

For movement of moisture and transport of contaminants in the vertical direction, two equations, the Richards equation and the advection-dispersion equation, are solved in a vadose zone for prescribed water and contaminant influx conditions at the ground surface. Two different boundary conditions are considered, one with a single peak of sinusoidal variation and four peaks of finite duration, each of which is sinusoidal in shape. The moisture migration is solved and then the contaminant transport, which is coupled to moisture movement, is solved. In the case of a single influx on the ground surface, at first the hydraulic head and moisture content show a peak. Then above the peak and below the ground surface, the peaks tend to die out, showing a tendency to return to the initial state. The vertical profile of concentration also shows a single peak, which soon becomes stagnant because downward water migration is faster than concentration profile movement. In the case of four intermittent array of peaks, the hydraulic head and moisture content profiles tend to merge and combine together. The concentration profiles show appearance of four peaks clearly. However, although the peak value of concentration remains quite constant, the values may vary with the sorption coefficient because of repeated influx of water and contaminant through the top boundary, the ground surface. The penetration depth decreases with an increasing sorption coefficient. (authors)

54 ENVIRONMENTAL SCIENCES↗

Calendar Year 2009 Groundwater Monitoring Report, U.S. Department of Energy, Y-12 National Security Complex, Oak Ridge, Tennessee

This report contains the groundwater and surface water monitoring data that were obtained during calendar year (CY) 2009 at the U.S. Department of Energy (DOE) Y-12 National Security Complex (hereafter referenced as Y-12) on the DOE Oak Ridge Reservation (ORR) in Oak Ridge, Tennessee. The CY 2009 monitoring data were obtained from wells, springs, and surface water sampling locations in three hydrogeologic regimes at Y-12. The Bear Creek Hydrogeologic Regime (Bear Creek Regime) encompasses a section of Bear Creek Valley (BCV) between the west end of Y-12 and the west end of the Bear Creek Watershed (directions are in reference to the Y-12 grid system). The Upper East Fork Poplar Creek Hydrogeologic Regime (East Fork Regime) encompasses the Y-12 industrial facilities and support structures in BCV. The Chestnut Ridge Hydrogeologic Regime (Chestnut Ridge Regime) encompasses a section of Chestnut Ridge directly south of Y-12. Section 2 of this report provides background information pertinent to groundwater and surface water quality monitoring in each hydrogeologic regime, including the topography and bedrock geology, surface water drainage, groundwater system, and extent of groundwater contamination. The CY 2009 groundwater and surface water monitoring data in this report were obtained from sampling and analysis activities implemented under the Y-12 Groundwater Protection Program (GWPP) managed by Babcock & Wilcox Technical Services Y-12, LLC (B&W Y-12) and from sampling and analysis activities implemented under several monitoring programs managed by Bechtel Jacobs Company LLC (BJC). Cooperative implementation of the monitoring programs directed by the Y-12 GWPP and BJC (i.e., coordinating sample collection and sharing data) ensures that the CY 2009 monitoring results fulfill requirements of all the applicable monitoring drivers with no duplication of sampling and analysis efforts. Section 3 of this report contains a summary of information regarding the groundwater and surface water sampling and analysis activities implemented under the Y-12 GWPP including sampling locations and frequency; quality assurance (QA)/quality control (QC) sampling; sample collection and handling; field measurements and laboratory analytes; data management and data quality objective (DQO) evaluation; and groundwater elevation monitoring. However, this report does not include equivalent QA/QC or DQO evaluation information regarding the groundwater and surface water sampling and analysis activities associated with the monitoring programs implemented by BJC. Such details are deferred to the respective programmatic plans and reports issued by BJC (see Section 3.0). Collectively, the groundwater and surface water monitoring data obtained during CY 2009 by the Y-12 GWPP and BJC address DOE Order 450.1A (Environmental Protection Program) requirements for monitoring groundwater and surface water quality in areas: (1) which are, or could be, affected by operations at Y-12 (surveillance monitoring); and (2) where contaminants from Y-12 are most likely to migrate beyond the boundaries of the ORR (exit pathway/perimeter monitoring). Section 4 of this report presents a summary evaluation of the monitoring data with regard to the respective objectives of surveillance monitoring and exit pathway/perimeter monitoring, based on the analytical results for the principal groundwater contaminants at Y-12: nitrate, uranium, volatile organic compounds (VOCs), gross alpha activity, and gross beta activity. Section 5 of this report summarizes the most pertinent findings regarding the principal contaminants, along with recommendations proposed for ongoing groundwater and surface water quality monitoring performed under the Y-12 GWPP. Narrative sections of this report reference several appendices. Figures (maps and diagrams) and tables (excluding data summary tables presented in the narrative sections) are in Appendix A and Appendix B, respectively. Appendix C contains construction details for the wells in each regime that were sampled during CY 2009 by either the Y-12 GWPP or BJC. Field measurements recorded during collection of the groundwater and surface water samples and results of laboratory analyses of the samples are in Appendix D (Bear Creek Regime), Appendix E (East Fork Regime and surrounding areas), and Appendix F (Chestnut Ridge Regime). Appendix G contains data for the QA/QC samples associated with monitoring performed in each regime by the Y-12 GWPP.

54 ENVIRONMENTAL SCIENCES↗

Elucidating Bioreductive Transformations within Physically Complex Media: Impact on the Fate and Transport of Uranium and Chromium

In situ stabilization (inclusive of natural attenuation) of toxic metals and radionuclides is an attractive approach for remediating many contaminated DOE sites. By immobilizing toxic metals and radionuclides in place, the removal of contaminated water to the surface for treatment as well as the associated disposal costs are avoided. To enhance in situ remediaton, microbiological reductive stabilization of contaminant metals has been, and continues to be, actively explored. It is likely that surface and subsurface microbial activity can alter the redox state of toxic metals and radionuclides, either directly or indirectly, so they are rendered immobile. Furthermore, anaerobic bacterial metabolic products will help to buffer pulses of oxidation, typically from fluxes of nitrate or molecular oxygen, and thus may stabilize reduced contaminants from oxidative mobilization. Uranium and chromium are two elements of particular concern within the DOE complex that, owing to their abundance and toxicity, appear well suited for biologically mediated reductive stabilization. Subsurface microbial activity can alter the redox state of toxic metals and radionuclides, rending them immobile. Imparting an important criterion on the probability that contaminants will undergo reductive stabilization, however, is the chemical and physical heterogeneity of the media. Our research first examined microbially induced transformation of iron (hydr)oxide minerals and their impact on contaminant attenuation. We revealed that in intricate cascade of geochemical reactions is induced by microbially produced Fe(II), and that during transformation contaminants such as U(VI) can be incorporated into the structure, and a set of Fe(II) bearing solids capable of reducing Cr(VI) and stabilizing resulting Cr(III). We also note, however, that common subsurface constituents such as phosphate can modify iron oxide transformation pathways and thus impact contaminant sequestration—affecting both Cr and U stabilization. We extended our work to explore factors controlling the sequestration of uranium in the subsurface, with a particular emphasis on mineralogic and geochemical complexity. We reveal that one of the primary factors controlling uranium reduction, via both biological and chemical pathways, is the aqueous speciation of U(VI). Specifically, ternary calcium-uranyl-carbonato complexes stabilize U(VI) relative to reduction. However, countering the lack of reduction, we note a novel sequestration pathway in which the U(VI), as the uranate ion, is incorporated into the structure of transformation iron oxides; magnetite and goethite, both products of Fe(II) induced transformation of ferrihydrite, harbor appreciable quantities of uranium. In sum, our results provide important information on predicting and potentially controlling the migration of chromium and uranium within the DOE complex.

54 ENVIRONMENTAL SCIENCES↗

Final Report, Elucidating Bioreductive Transformations within Physically Complex Media: Impact on the Fate and Transport of Uranium and Chromium

In situ stabilization (inclusive of natural attenuation) of toxic metals and radionuclides is an attractive approach for remediating many contaminated DOE sites. By immobilizing toxic metals and radionuclides in place, the removal of contaminated water to the surface for treatment as well as the associated disposal costs are avoided. To enhance in situ remediaton, microbiological reductive stabilization of contaminant metals has been, and continues to be, actively explored. It is likely that surface and subsurface microbial activity can alter the redox state of toxic metals and radionuclides, either directly or indirectly, so they are rendered immobile. Furthermore, anaerobic bacterial metabolic products will help to buffer pulses of oxidation, typically from fluxes of nitrate or molecular oxygen, and thus may stabilize reduced contaminants from oxidative mobilization. Uranium and chromium are two elements of particular concern within the DOE complex that, owing to their abundance and toxicity, appear well suited for biologically mediated reductive stabilization. Subsurface microbial activity can alter the redox state of toxic metals and radionuclides, rending them immobile. Imparting an important criterion on the probability that contaminants will undergo reductive stabilization, however, is the chemical and physical heterogeneity of the media. Our research first examined microbially induced transformation of iron (hydr)oxide minerals and their impact on contaminant attenuation. We revealed that in intricate cascade of geochemical reactions is induced by microbially produced Fe(II), and that during transformation contaminants such as U(VI) can be incorporated into the structure, and a set of Fe(II) bearing solids capable of reducing Cr(VI) and stabilizing resulting Cr(III). We also note, however, that common subsurface constituents such as phosphate can modify iron oxide transformation pathways and thus impact contaminant sequestration—affecting both Cr and U stabilization. We extended our work to explore factors controlling the sequestration of uranium in the subsurface, with a particular emphasis on mineralogic and geochemical complexity. We reveal that one of the primary factors controlling uranium reduction, via both biological and chemical pathways, is the aqueous speciation of U(VI). Specifically, ternary calcium-uranyl-carbonato complexes stabilize U(VI) relative to reduction. However, countering the lack of reduction, we note a novel sequestration pathway in which the U(VI), as the uranate ion, is incorporated into the structure of transformation iron oxides; magnetite and goethite, both products of Fe(II) induced transformation of ferrihydrite, harbor appreciable quantities of uranium. In sum, our results provide important information on predicting and potentially controlling the migration of chromium and uranium within the DOE complex.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimally-controlled hybrid phytoremediation system

A method for treating chemicals below ground is provided. The system includes contacting the chemicals with a rhizosphere to maximize transpiration rate and minimize over-saturation of the rhizosphere. Also provided is a method for using contaminated groundwater as a sole source of irrigation. The method uses extracting the contaminated water and pumping the extracted water to an irrigation zone under the control of an autonomous irrigation system. Each zone includes some trees and the root system for each tree is modified to function as a treatment cell. The invention also provides a system for treating contaminated water, using a contaminated water source situated below ground surface. The system uses a pump for extracting contaminated water from the water source and prevents the contaminated water from directly contacting the atmosphere above the ground surface. Vegetation which defines an underground rhizosphere is adapted to directly receive the water.

Yan, Y. Eugene↗

Genesis Concentrator Target Particle Contamination Mapping and Material Identification

The majority of surface particles were found to be < 5 microns in diameter with increasing numbers close to the optical resolution limit of 0.3 microns. Acceleration grid EDS results show that the majority of materials appear to be from the SRC shell and SLA materials which include carbon-carbon fibers and Si-rich microspheres in a possible silicone binder. Other major debris material from the SRC included white paint, kapton, collector array fragments, and Al. Image analysis also revealed that SRC materials were also found mixed with the Utah mud and salt deposits. The EDS analysis of the acceleration grid showed that particles < 1 m where generally carbon based particles. Chemical cleaning techniques with Xylene and HF in an ultrasonic bath are currently being investigated for removal of small particles by the Genesis science team as well as ultra-pure water megasonic cleaning by the JSC team [4]. Removal of organic contamination from target materials is also being investigated by the science team with the use of UV-ozone cleaning devices at JSC and Open University [5]. In preparation for solar wind oxygen analyses at UCLA and Open University [1, 2], surface particle contamination on three Genesis concentrator targets was closely examined to evaluate cleaning strategies. Two silicon carbide (Genesis sample # 60001 and 60003) and one chemical vapor deposited (CVD) 13C concentrator target (60002) were imaged and mosaic mapped with optical microscopes. The resulting full target mosaic images and particle feature maps were subsequently compared with non-flight, but flight-like, concentrator targets and sample return capsule (SRC) materials. Contamination found on the flown concentrator acceleration grid was further examined using a scanning electron microscope (SEM). Energy dispersive X-ray spectroscopy (EDS) for particle identification was subsequently compared with the optical images from the flown targets. Figure 1 show that all three targets imaged in this report are fully intact and do not show any signs of material fractures. However, previous ellipsometry results and overview imaging of both flown SiC targets show a solar wind irradiation gradient from the center focal point to the outer edge [3]. In addition, due to the hard landing, each target has experienced varying degrees of impacts, scratches, and particle debris from the spacecraft and Utah impact site.

Calaway, Michael J.↗

CONTAMINATION CONTROL FOR ULTRA-SENSITIVE LIFE DETECTION SCIENCE MISSIONS

"This study report summarizes technological developments in science-required contamination control for cost-capped, life-detection missions in the Solar System. Technology advances focus on developing implementable strategies to restrict contamination of the spacecraft and instruments by the launch vehicle hardware. Secondary bake out operations during cruise further reduce molecular contaminants down to femtomolar levels in the sample path. The study validated a full-spacecraft, deployable barrier design as an effective strategy to isolate the spacecraft from the pre-launch processing and launch environment (e.g., fairing acoustic materials). It accommodates late mounting of RTGs and other required prelaunch activities. A new, high-fidelity physics, contamination-transport model for particles (including cells and their parts) and science-relevant molecules (e.g., possible biomolecules) was developed to validate the barrier concept. Importantly, this model takes into account the physics of extremely clean surfaces achieved by the best traditional contamination engineering. The ability to deal with very low levels of particulate and molecular contamination makes this model unique among standard contamination modeling approaches. Modeling also demonstrated that a high-temperature bake out during interplanetary cruise of the sample collector that comprises the largest surface area in the sample path for an Enceladus orbiter reference mission, was extremely effective. This study included the evaluation of other details necessary for an effective contamination control strategy for life detection missions including feasibility of achieving parts per trillion level cleanliness for semi-volatile hydrocarbons in nitrogen purge gas, identification of launch vehicle services required for the baseline contamination control, and defining additional contamination control measures to be taken during launch operations. Key results of the study are: • New spacecraft barrier design that accommodates RTGs is readily cleanable and repairable. Deployment of a 1/3 scale model was successfully demonstrated. • The barrier reduces particle contamination (likely biological) from fairing to spacecraft by 1e-2 to 1e-3. • On-cruise bake-out of critical surfaces significantly reduced molecular contamination (by as much as 1e-12). Subsequently, the probability of a surface contamination particle being transported to an instrument by an ice particle is less than 5.1e-5 (for microbes specifically, 4.39e-10). The report concludes that a full-spacecraft barrier designed specifically for life-detection missions that require stringent control of particulate and molecular contaminates is an effective means of mitigating risks of false positive and negative results for life signature investigations. Further, secondary cleaning steps for critical sections of the sample path can be highly effective at reducing molecular contaminants to low femtomolar levels."

Contamination↗

Contamination Control for Ultra-Sensitive Life-Detection Missions

"This study report summarizes technological developments in science-required contamination control for cost-capped, life-detection missions in the Solar System. Technology advances focus on developing implementable strategies to restrict contamination of the spacecraft and instruments by the launch vehicle hardware. Secondary bake out operations during cruise further reduce molecular contaminants down to femtomolar levels in the sample path. The study validated a full-spacecraft, deployable barrier design as an effective strategy to isolate the spacecraft from the pre-launch processing and launch environment (e.g., fairing acoustic materials). It accommodates late mounting of RTGs and other required prelaunch activities. A new, high-fidelity physics, contamination-transport model for particles (including cells and their parts) and science-relevant molecules (e.g., possible biomolecules) was developed to validate the barrier concept. Importantly, this model takes into account the physics of extremely clean surfaces achieved by the best traditional contamination engineering. The ability to deal with very low levels of particulate and molecular contamination makes this model unique among standard contamination modeling approaches. Modeling also demonstrated that a high-temperature bake out during interplanetary cruise of the sample collector that comprises the largest surface area in the sample path for an Enceladus orbiter reference mission, was extremely effective. This study included the evaluation of other details necessary for an effective contamination control strategy for life detection missions including feasibility of achieving parts per trillion level cleanliness for semi-volatile hydrocarbons in nitrogen purge gas, identification of launch vehicle services required for the baseline contamination control, and defining additional contamination control measures to be taken during launch operations. Key results of the study are: • New spacecraft barrier design that accommodates RTGs is readily cleanable and repairable. Deployment of a 1/3 scale model was successfully demonstrated. • The barrier reduces particle contamination (likely biological) from fairing to spacecraft by 1e-2 to 1e-3. • On-cruise bake-out of critical surfaces significantly reduced molecular contamination (by as much as 1e-12). Subsequently, the probability of a surface contamination particle being transported to an instrument by an ice particle is less than 5.1e-5 (for microbes specifically, 4.39e-10). The report concludes that a full-spacecraft barrier designed specifically for life-detection missions that require stringent control of particulate and molecular contaminates is an effective means of mitigating risks of false positive and negative results for life signature investigations. Further, secondary cleaning steps for critical sections of the sample path can be highly effective at reducing molecular contaminants to low femtomolar levels."

contamination, life detection, barrier, modeling↗