Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibrating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Calibration of Multi-Parameter Models of Avascular Tumor Growth Using Time Resolved Microscopy Data

Abstract Two of the central challenges of using mathematical models for predicting the spatiotemporal development of tumors is the lack of appropriate data to calibrate the parameters of the model, and quantitative characterization of the uncertainties in both the experimental data and the modeling process itself. We present a sequence of experiments, with increasing complexity, designed to systematically calibrate the rates of apoptosis, proliferation, and necrosis, as well as mobility, within a phase-field tumor growth model. The in vitro experiments characterize the proliferation and death of human liver carcinoma cells under different initial cell concentrations, nutrient availabilities, and treatment conditions. A Bayesian framework is employed to quantify the uncertainties in model parameters. The average difference between the calibration and the data, across all time points is between 11.54% and 14.04% for the apoptosis experiments, 7.33% and 23.30% for the proliferation experiments, and 8.12% and 31.55% for the necrosis experiments. The results indicate the proposed experiment-computational approach is generalizable and appropriate for step-by-step calibration of multi-parameter models, yielding accurate estimations of model parameters related to rates of proliferation, apoptosis, and necrosis.

60 APPLIED LIFE SCIENCES↗

The throughput calibration of the VERITAS telescopes

Context. The response of imaging atmospheric Cherenkov telescopes to incident γ -ray-initiated showers in the atmosphere changes as the telescopes age due to exposure to light and weather. These aging processes affect the reconstructed energies of the events and γ -ray fluxes. Aims. This work discusses the implementation of signal calibration methods for the Very Energetic Radiation Imaging Telescope Array System (VERITAS) to account for changes in the optical throughput and detector performance over time. Methods. The total throughput of a Cherenkov telescope is the product of camera-dependent factors, such as the photomultiplier tube gains and their quantum efficiencies, and the mirror reflectivity and Winston cone response to incoming radiation. This document summarizes different methods to determine how the camera gains and mirror reflectivity have evolved over time and how we can calibrate this changing throughput in reconstruction pipelines for imaging atmospheric Cherenkov telescopes. The implementation is validated against seven years of observations with the VERITAS telescopes of the Crab Nebula, which is a reference object in very-high-energy astronomy. Results. Regular optical throughput monitoring and the corresponding signal calibrations are found to be critical for the reconstruction of extensive air shower images. The proposed implementation is applied as a correction to the signals of the photomultiplier tubes in the telescope simulation to produce fine-tuned instrument response functions. This method is shown to be effective for calibrating the acquired γ -ray data and for recovering the correct energy of the events and photon fluxes. At the same time, it keeps the computational effort of generating Monte Carlo simulations for instrument response functions affordably low.

79 ASTRONOMY AND ASTROPHYSICS↗

Development and operational experience of the web based application to collect, manage, and release the alignment and calibration configurations for data processing at CMS

The alignment and calibration workflows at the Compact Muon Solenoid (CMS) experiment are fundamental to provide a high quality physics data and to maintain the design performance of the experiment. To facilitate the operational efforts required by the experiment, the alignment and calibration team has developed and deployed a set of web-based applications to search, navigate and prepare a consistent set of calibrations to be consumed in reconstruction of data for physics, accessible through the Condition DB Browser. The Condition DB Browser hosts also various data management tools, including a visualization tool that allows to easily inspect alignment an calibration contents, an user-defined notification agent for delivering updates on modification to the database, a logging service for the user and the automatic online-to-offline condition uploads. In this paper we report on the operational experience of this web application from 2017 data taking, with focus on new features and tools incorporated during this period.

Md, Hasbuddin↗

AI Driven Experiment Calibration and Control

One critical step on the path from data taking to physics analysis is calibration. For many experiments this step is both time consuming and computationally expensive. The AI Experimental Calibration and Control project seeks to address these issues, starting first with the GlueX Central Drift Chamber (CDC). We demonstrate the ability of a Gaussian Process to estimate the gain correction factor (GCF) of the GlueX CDC accurately, and also the uncertainty of this estimate. Using the estimated GCF, the developed system infers a new high voltage (HV) setting that stabilizes the GCF in the face of changing environmental conditions. This happens in near real time during data taking and produces data which are already approximately gain-calibrated, eliminating the cost of performing those calibrations which vary ±15% with fixed HV. We also demonstrate an implementation of an uncertainty aware system which exploits a key feature of a Gaussian process.

Britton, Thomas↗

CALIBRATING THE JOHNSON-HOLMQUIST CERAMIC MODEL FOR SIC USING CTH

The Johnson-Holmquist ceramic material model has been calibrated and successfully applied to numerically simulate ballistic events using the Lagrangian code EPIC. While the majority of the constants are ''physics'' based, two of the constants for the failed material response are calibrated using ballistic experiments conducted on a confined cylindrical ceramic target. The maximum strength of the failed ceramic is calibrated by matching the penetration velocity. The second refers to the equivalent plastic strain at failure under constant pressure and is calibrated using the dwell time. Use of these two constants in the CTH Eulerian hydrocode does not predict the ballistic response. This difference may be due to the phenomenological nature of the model and the different numerical schemes used by the codes. This paper determines the aforementioned material constants for SiC suitable for simulating ballistic events using CTH.

36 MATERIALS SCIENCE↗

Broad-band efficiency calibration of ITER bolometer prototypes using Pt absorbers on SiN membranes

The energy resolved efficiency of two bolometer detector prototypes for ITER with 4 channels each and absorber thicknesses of 4.5 μm and 12.5 μm, respectively, has been calibrated in a broad spectral range from 1.46 eV up to 25 keV. The calibration in the energy range above 3 eV was performed against previously calibrated silicon photodiodes using monochromatized synchrotron radiation provided by five different beamlines of Physikalische Technische Bundesanstalt at the electron storage rings BESSY II and Metrology Light Source in Berlin. For the measurements in the visible range, a setup was realised using monochromatized halogen lamp radiation and a calibrated laser power meter as reference. The measurements clearly demonstrate that the efficiency of the bolometer prototype detectors in the range from 50 eV up to ≈6 keV is close to unity; at a photon energy of 20 keV the bolometer with the thick absorber detects 80% of the photons, the one with the thin absorber about 50%. This indicates that the detectors will be well capable of measuring the plasma radiation expected from the standard ITER scenario. However, a minimum absorber thickness will be required for the high temperatures in the central plasma. At 11.56 keV, the sharp Pt-L{sub 3} absorption edge allowed to cross-check the absorber thickness by fitting the measured efficiency to the theoretically expected absorption of X-rays in a homogeneous Pt-layer. Furthermore, below 50 eV the efficiency first follows the losses due to reflectance expected for Pt, but below 10 eV it is reduced further by a factor of 2 for the thick absorber and a factor of 4 for the thin absorber. Most probably, the different histories in production, storage, and operation led to varying surface conditions and additional loss channels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser calibration of the DIII-D coherence imaging system

Here, we describe an in situ calibration technique for Coherence Imaging Spectroscopy (CIS) that measures 2-D images of ion flows on DIII-D. A low power CW diode laser that is tuneable in the range 464-468 nm along with a precision wavemeter (10 –5 nm resolution) is used to characterize the interferometer phase as a function of wavelength in the region of C iii (465 nm) and He ii (468 nm). The interferometer is stabilized both mechanically and thermally to minimize drift during the calibration. Optical stirring and an integration sphere are utilized to obtain spatially uniform calibration images. The quality of the calibration data enables a measurement of phase versus wavelength over approximately 10 fringes of the interferometer. These coefficients can also be related to the geometry of the optics and the birefringent crystal of the interferometer. On DIII-D, the integration sphere with the laser light is inserted into the CIS optical system between shots and the laser image and wavelength are automatically recorded, providing a zero velocity reference

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Warm Electron Beam Ion Trap (WEBIT): An instrument for ground calibration of space-borne x-ray spectrometers

The warm electron beam ion trap (WEBIT) at Lawrence Livermore National Laboratory is being developed as a pre-launch, ground calibration source for space-borne, high-throughput, high-resolution x-ray spectrometers, such as the x-ray imaging and spectroscopy mission Resolve quantum calorimeter. Historically, calibration sources for calorimeter spectrometers have relied on characteristic line emission from x-ray tubes, fluorescing metals, and radioactive sources. The WEBIT, by contrast, relies on emission from x-ray transitions in highly charged ions, for example, hydrogen-like and helium-like ions, whose energies are well known and whose line shapes are relatively simple. The WEBIT can create astrophysically relevant ions whose x-ray emission falls in the 0.3-12 keV science bandpass of Resolve and has a portable design advantageous for a calibration source. The WEBIT will be used to help calibrate Resolve’s instrumental line shape and gain scale as a function of various operational parameters during both detector subsystem level testing and instrumental level testing.

47 OTHER INSTRUMENTATION↗

Absolute calibration of GafChromic film for very high flux laser driven ion beams

We report on the calibration of GafChromic HD-v2 radiochromic film in the extremely high dose regime up to 100 kGy together with very high dose rates up to 7 × 10 11 Gy/s. The absolute calibration was done with nanosecond ion bunches at the Neutralized Drift Compression Experiment II particle accelerator at Lawrence Berkeley National Laboratory (LBNL) and covers a broad dose dynamic range over three orders of magnitude. We then applied the resulting calibration curve to calibrate a laser driven ion experiment performed on the BELLA petawatt laser facility at LBNL. Here, we reconstructed the spatial and energy resolved distributions of the laser-accelerated proton beams. The resulting proton distribution is in fair agreement with the spectrum that was measured with a Thomson spectrometer in combination with a microchannel plate detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ex situ calibration of the scattered-light time-history diagnostic on the National Ignition Facility

The scattered-light time-history diagnostic (SLTD) suite measures time-resolved scattered light in three wavelength bands: stimulated Brillouin scattering (350–352 nm), stimulated Raman scattering (430–760 nm), and plasma emission at half the laser frequency (695–735 nm), at 15 locations around the National Ignition Facility (NIF) target chamber. The SLTD, along with the full-aperture backscatter station (FABS), collects scattered light from direct- and indirect-drive inertial confinement fusion experiments. The SLTD calibration was revisited after a discrepancy between FABS and SLTD measurements was observed on NIF polar direct-drive experiments. An integrated calibration of the SLTD was performed for the first time, and individual components were also calibrated for the wavelengths of 351, 527, and 532 nm. The optical transmission of the instrument was measured to be (1.12 ± 0.04) × 10 –7 and (1.96 ± 0.11) × 10 –7 for the wavelengths of 351 and 532 nm, respectively. The revised calibration at 351 nm brings the SLTD measured scattered energy in agreement with the FABS measured scattered energy after additionally accounting for the degradation of an optical element in FABS. Furthermore, this decreased the inferred absorption by 7% for a representative experiment. However, discrepancies remain between FABS and SLTD measurements in the SRS band (532 nm).

47 OTHER INSTRUMENTATION↗

Characterization of the response of radiochromic film to quasi-monoenergetic x rays through a cross-calibration with image plates

Radiochromic film (RCF) and image plates (IPs) are both commonly used detectors in diagnostics fielded at inertial confinement fusion (ICF) and high-energy-density physics (HEDP) research facilities. Due to the intense x-ray background in all ICF/HEDP experiments, accurately calibrating the optical density of RCF as a function of x-ray dose, and the photostimulated luminescence per photon of IPs as a function of x-ray energy, is necessary for interpreting experimental results. Various measurements of the sensitivity curve of different IPs to x rays have been performed [Izumi et al., Proc. SPIE 8850, 885006 (2013) and Rosenberg et al., Rev. Sci. Instrum. 90(1), 013506 (2019)]; however, calibrating RCF is a tedious process that depends on factors such as the orientation in which the RCF is scanned in the film scanner and the batch of RCF used. These issues can be mitigated by cross-calibrating RCF with IPs to enable the use of IPs for the determination of dose on the RCF without scanning the RCF. Here, the first cross-calibration of RCF with IPs to quasi-monoenergetic titanium, copper, and molybdenum K-line x rays is presented. It is found that the IP-inferred dose rates on the RCF for the Ti and Mo x rays agree well with the measured dose rates, while the IP-inferred dose rate for the Cu x rays is larger than the measured dose rate by ∼2×. Explanations for this discrepancy and plans for future work are discussed.

Instruments & Instrumentation↗

Permanent densification of silica glass for pressure calibration between 9 and 20 GPa at ambient temperature

Permanent density increase of silica glass was used to calibrate pressure generation delivered by cupped sintered diamond anvils (‘dimple anvils’) [Haberl B, Molaison JJ, Neuefeind JC, et al. Simple modified Bridgman anvil design for high pressure synthesis and neutron scattering. High Press. Res. submitted] within the Paris-Edinburgh press between approximately 9 and 20 GPa. Raman spectral changes of recovered silica glass with increased density were used to determine the maximum pressure reached by following an established calibration curve [Deschamps T, Kassir-Bodon A, Sonneville C, et al. Permanent densification of compressed silica glass: a Raman-density calibration curve. J. Phys. Condens. Matter. 2013;25:025402]. The monotonic Raman shift of the Main Band spectral region (~200–700 cm-1) of silica glass recovered from 9 to 20 GPa allows for continuous pressure calibration and is applicable to all presses that operate within this pressure range. Radial & axial Raman profiles were conducted to determine the pressure distribution within the sample chamber. This technique has been verified by in situ resistance measurements of the insulator-to-metal phase transition of ZnS near 15 GPa.

catalysis (heterogeneous)↗

CARNEGIE HUBBLE PROGRAM: A MID-INFRARED CALIBRATION OF THE HUBBLE CONSTANT

Using a mid-infrared calibration of the Cepheid distance scale based on recent observations at 3.6 {mu}m with the Spitzer Space Telescope, we have obtained a new, high-accuracy calibration of the Hubble constant. We have established the mid-IR zero point of the Leavitt law (the Cepheid period-luminosity relation) using time-averaged 3.6 {mu}m data for 10 high-metallicity, Milky Way Cepheids having independently measured trigonometric parallaxes. We have adopted the slope of the PL relation using time-averaged 3.6 {mu}m data for 80 long-period Large Magellanic Cloud (LMC) Cepheids falling in the period range 0.8 < log(P) < 1.8. We find a new reddening-corrected distance to the LMC of 18.477 {+-} 0.033 (systematic) mag. We re-examine the systematic uncertainties in H{sub 0}, also taking into account new data over the past decade. In combination with the new Spitzer calibration, the systematic uncertainty in H{sub 0} over that obtained by the Hubble Space Telescope Key Project has decreased by over a factor of three. Applying the Spitzer calibration to the Key Project sample, we find a value of H{sub 0} = 74.3 with a systematic uncertainty of {+-}2.1 (systematic) km s{sup -1} Mpc{sup -1}, corresponding to a 2.8% systematic uncertainty in the Hubble constant. This result, in combination with WMAP7 measurements of the cosmic microwave background anisotropies and assuming a flat universe, yields a value of the equation of state for dark energy, w{sub 0} = -1.09 {+-} 0.10. Alternatively, relaxing the constraints on flatness and the numbers of relativistic species, and combining our results with those of WMAP7, Type Ia supernovae and baryon acoustic oscillations yield w{sub 0} = -1.08 {+-} 0.10 and a value of N{sub eff} = 4.13 {+-} 0.67, mildly consistent with the existence of a fourth neutrino species.

79 ASTRONOMY AND ASTROPHYSICS↗

Weak Lensing Mass Calibration of the ACT DR5 Galaxy Clusters with the DES Year 3 Weak Lensing Data

We use weak gravitational lensing measurements from Year 3 Dark Energy Survey data to calibrate the masses of 443 galaxy clusters selected via the Sunyaev-Zel'dovich effect from Atacama Cosmology Telescope Data Release 5 maps of the cosmic microwave background. We incorporate redshift and SZ measurements for individual clusters into a hierarchical model for the stacked lensing signals and perform Bayesian analyses to constrain the hydrostatic mass bias of the clusters. Our treatment of systematic uncertainties includes a prescription for measuring and accounting for the weak lensing boost factor, consideration of a miscentering effect, as well as marginalization over uncertainties in the source galaxy photometric redshift distributions and shear calibration. The resultant constraints on the normalization of the mass-observable relation have a precision of approximately 7%, with the mean WL halo mass of M $_{500c}$ = 5.4 × 10$^{14}$ M $_{⊙}$. We measure the bias between the true cluster mass and the mass estimated from the SZ signal based on an X-ray-calibrated scaling relation assuming hydrostatic equilibrium, to be 1 - b = 0.74$^{+0.06}$ $_{-0.05}$ over the full sample. When splitting the clusters into high (z = 0.43-0.70) and low (z = 0.15-0.43) redshift bins, we measure 1 - b = 0.58$^{+0.06}$ $_{-0.05}$ and 0.81$^{+0.08}$ $_{-0.06}$, respectively. When introducing additional freedom in redshift and mass to the hydrostatic bias model, we find that 1 - b decreases with redshift (with the power law of -1.8$^{+0.5}$ $_{-0.6}$, 99.95% confidence), consistent with findings from other recent studies, while we do not find any significant trend in mass. We also demonstrate that our result is robust against various systematics such as a scale cut, priors on baryonic and miscentering parameters, and degree of scatter in mass-observable relation. The weak-lensing mass calibration presented in this study will be a useful tool for using the ACT clusters as probes of astrophysics, and as a step towards using their abundance as a cosmological probe.

Shin, T. [Carnegie Mellon U.] (ORCID:0000000263895↗

Photometric Calibration for the Beijing–Arizona Sky Survey and Mayall z -band Legacy Survey

We present the photometric calibration of the Beijing–Arizona Sky Survey and Mayall z-band Legacy Survey, which are two of the three wide-field optical legacy imaging surveys to provide the baseline targeting data for the Dark Energy Spectroscopic Instrument project. The method of our photometric calibration is subdivided into the external and internal processes. The former utilizes the point-source objects of Pan-STARRS1 survey (PS1) as the reference standards to achieve the zero points of the absolute flux for individual exposures. And then the latter revise the zero points to make them consistent across the survey based on multiple tilings and large offset overlaps. Our process achieves a homogeneous photometric calibration over most of the sky with precision better than 10 mmag for g and r bands, 15 mmag for z band. The accuracy of the calibration is better than 1% at the bright end (16–18 mag) over most of the survey area.

79 ASTRONOMY AND ASTROPHYSICS↗

A Web-based application for the collection, management and release of Alignment and Calibration configurations used in data processing at the Compact Muon Solenoid experiment

The Compact Muon Solenoid (CMS) experiment makes a vast use of alignment and calibration measurements in several data processing workflows: in the High Level Trigger, in the processing of the recorded collisions and in the production of simulated events for data analysis and studies of detector upgrades. A complete alignment and calibration scenario is factored in approximately three-hundred records, which are updated independently and can have a time-dependent content, to reflect the evolution of the detector and data taking conditions. Given the complexity of the CMS condition scenarios and the large number (50) of experts who actively measure and release calibration data, in 2015 a novel web-based service has been developed to structure and streamline their management. The cmsDbBrowser provides an intuitive and easily accessible entry point for the navigation of existing conditions by any CMS member, for the bookkeeping of record updates and for the actual composition of complete calibration scenarios. This paper describes the design, choice of technologies and the first year of usage in production of the cmsDbBrowser.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration and performance of the ATLAS Tile Calorimeter during the LHC Run 2

The Tile Calorimeter (TileCal) is the hadronic sampling calorimeter of the ATLAS experiment at the Large Hadron Collider (LHC). TileCal uses iron absorbers and scintillators as active material and it covers the central region | η| < 1.7. Jointly with the other sub-detectors it is designed for measurements of hadrons, jets, tau-particles and missing transverse energy. It also assists in muon identification. TileCal is regularly monitored and calibrated by several different calibration systems: a Cs radioactive source, a laser light system to check the PMT response, and a charge injection system (CIS) to check the front-end electronics. These calibration systems, in conjunction with data collected during proton-proton collisions, Minimum Bias (MB) events, provide extensive monitoring of the instrument and a means for equalizing the calorimeter response at each stage of the signal propagation. The performance of the calorimeter has been established with cosmic ray muons and the large sample of the proton-proton collisions and compared to Monte Carlo (MC) simulations. The response of high momentum isolated muons is also used to study the energy response at the electromagnetic scale, isolated hadrons are used as a probe of the hadronic response. The calorimeter time resolution is studied with multijet events. A description of the different TileCal calibration systems and the results on the calorimeter performance during the LHC Run 2 are introduced. The findings on the pile-up noise and response uniformity studies are also reported on.

47 OTHER INSTRUMENTATION↗

Development of a 127 Xe calibration source for nEXO

Here, we study a possible calibration technique for the nEXO experiment using a 127 Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay (0νββ) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in 136 Xe. To optimize the event reconstruction and energy resolution, calibrations are needed to map the position- and time-dependent detector response. The 36.3 day half-life of 127 Xe and its small Q-value compared to that of 136 Xe 0νββ would allow a small activity to be maintained continuously in the detector during normal operations without introducing additional backgrounds, thereby enabling in-situ calibration and monitoring of the detector response. In this work we describe a process for producing the source and preliminary experimental tests. We then use simulations to project the precision with which such a source could calibrate spatial corrections to the light and charge response of the nEXO TPC.

47 OTHER INSTRUMENTATION↗