Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power system faults”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Cause identification of electromagnetic transient events using spatiotemporal feature learning

This paper presents a spatiotemporal feature learning method for cause identification of electromagnetic transient events in power grids. The proposed method is formulated based on the availability of time-synchronized high-frequency measurements and using the convolutional neural network as the spatiotemporal feature representation along with softmax function for the classification. Despite the existing threshold-based, or energy-based events analysis methods, such as support vector machine autoencoder, and tapered multi-layer perceptron neural network, the proposed feature learning is carried out with respect to both time and space. The effectiveness of the proposed feature learning and the subsequent cause identification is validated through the Electromagnetic Transients Program (EMTP) simulation of different events such as line energization, capacitor bank energization, lightning, fault, and high-impedance fault in the IEEE 30-bus, and the real-time digital simulation of the Western System Coordinating Council (WSCC) 9-bus system.

42 ENGINEERING↗

Cable Tester Box

Cables are very important electrical devices that carry power and signals across multiple instruments. Any fault in a cable can easily result in a catastrophic outcome. Therefore, verifying that all cables are built to spec is a very important part of Electrical Integration Procedures. Currently, there are two methods used in lab for verifying cable connectivity. (1) Using a Break-Out Box and an ohmmeter this method is time-consuming but effective for custom cables and (2) Commercial Automated Cable Tester Boxes this method is fast, but to test custom cables often requires pre-programmed configuration files, and cables used on spacecraft are often uniquely designed for specific purposes. The idea is to develop a semi-automatic continuity tester that reduces human effort in cable testing, speeds up the electrical integration process, and ensures system safety. The JPL-Cable Tester Box is developed to check every single possible electrical connection in a cable in parallel. This system indicates connectivity through LED (light emitting diode) circuits. Users can choose to test any pin/shell (test node) with a single push of a button, and any other nodes that are shorted to the test node, even if they are in the same connector, will light up with the test node. The JPL-Cable Tester Boxes offers the following advantages: 1. Easy to use: The architecture is simple enough that it only takes 5 minutes for anyone to learn how operate the Cable Tester Box. No pre-programming and calibration are required, since this box only checks continuity. 2. Fast: The cable tester box checks all the possible electrical connections in parallel at a push of a button. If a cable normally takes half an hour to test, using the Cable Tester Box will improve the speed to as little as 60 seconds to complete. 3. Versatile: Multiple cable tester boxes can be used together. As long as all the boxes share the same electrical potential, any number of connectors can be tested together.

Lee, Jason H.↗

Development and Calibration of an Online Energy Model for AHU Fan

The model development is necessary for the study of the energy consumption of Heating, Ventilation, and Air Conditioning (HVAC) systems. To predict the HVAC energy consumption accurately, one needs to model the individual HVAC components either from the measured data or based on the knowledge of the underlying physical phenomenon. Online model characterization is critical for improving the performance of real-time model-based fault detection and diagnosis (FDD) strategies. For HVAC control, models can be used to optimize the supervisory and local feedback control strategies to improve the energy consumption efficiency, or for providing ancillary services to the grid. It has been reported that, fans in HVAC systems of commercial buildings alone can provide substantial frequency regulation service, with little change in the indoor environment. In this paper, a real-time data-driven Air Handling Unit (AHU) fan model was developed based on recursive multi regression model. A generic nonlinear polynomial model has been studied to cover scenarios with different combinations of measurement variables, variable orders as well as different training and prediction horizons. Typical measurements including static pressure, mass flow rate, and damper positions are utilized as inputs to model the power consumption of the fan. The developed models have been validated both with simulation data from EnergyPlus-Dymola co-simulation model and with field measurement data for small to medium commercial buildings. The validation results show that the online model proposed can provide an effective prediction of the AHU fan power consumption.

Dong, Jin↗

Design and performance validation of a high-temperature downhole permanent magnet generator used for an electro-pulse boring system in geothermal energy applications

Novel, direct-energy drilling technologies such as electro-pulse boring, have the potential to significantly increase the speed and depth of geothermal drilling but have not achieved widespread adoption due to several economic and technical barriers. One major challenge is that these drilling systems require electric power downhole. The current practice is to supply power to the drill string components by running electric cables down the geothermal well, but at the targeted well depths, this practice is cost-inhibitive, inefficient in terms of power consumption, and adds an additional failure point with the long cabling going through a highly corrosive, high-temperature environment. A solution to this problem is to develop high-temperature electric generator technology that can generate the required power downhole. Such a generator must also operate with high efficiency at the target downhole ambient temperature of 250 °C. In this paper, we investigate the various design considerations for this concept and subsequently design the downhole electric generator using a multi-objective design optimization approach. Through electromagnetic-, thermal- and short-circuit fault condition analysis, it is demonstrated that the optimized downhole electric generator concept presented in this paper can meet the performance requirements within this extreme drilling environment. Most remarkably, it is shown that a generator efficiency of 90% is achieved. In conclusion, to validate the results presented in this paper, a prototype generator is built and its performance is measured at 250 °C using a test bench uniquely developed for this application.

15 GEOTHERMAL ENERGY↗

Damage Detection Response Characteristics of Open Circuit Resonant (SansEC) Sensors

The capability to assess the current or future state of the health of an aircraft to improve safety, availability, and reliability while reducing maintenance costs has been a continuous goal for decades. Many companies, commercial entities, and academic institutions have become interested in Integrated Vehicle Health Management (IVHM) and a growing effort of research into "smart" vehicle sensing systems has emerged. Methods to detect damage to aircraft materials and structures have historically relied on visual inspection during pre-flight or post-flight operations by flight and ground crews. More quantitative non-destructive investigations with various instruments and sensors have traditionally been performed when the aircraft is out of operational service during major scheduled maintenance. Through the use of reliable sensors coupled with data monitoring, data mining, and data analysis techniques, the health state of a vehicle can be detected in-situ. NASA Langley Research Center (LaRC) is developing a composite aircraft skin damage detection method and system based on open circuit SansEC (Sans Electric Connection) sensor technology. Composite materials are increasingly used in modern aircraft for reducing weight, improving fuel efficiency, and enhancing the overall design, performance, and manufacturability of airborne vehicles. Materials such as fiberglass reinforced composites (FRC) and carbon-fiber-reinforced polymers (CFRP) are being used to great advantage in airframes, wings, engine nacelles, turbine blades, fairings, fuselage structures, empennage structures, control surfaces and aircraft skins. SansEC sensor technology is a new technical framework for designing, powering, and interrogating sensors to detect various types of damage in composite materials. The source cause of the in-service damage (lightning strike, impact damage, material fatigue, etc.) to the aircraft composite is not relevant. The sensor will detect damage independent of the cause. Damage in composite material is generally associated with a localized change in material permittivity and/or conductivity. These changes are sensed using SansEC. The unique electrical signatures (amplitude, frequency, bandwidth, and phase) are used for damage detection and diagnosis. An operational system and method would incorporate a SansEC sensor array on select areas of the aircraft exterior surfaces to form a "Smart skin" sensing surface. In this paper a new method and system for aircraft in-situ damage detection and diagnosis is presented. Experimental test results on seeded fault damage coupons and computational modeling simulation results are presented. NASA LaRC has demonstrated with individual sensors that SansEC sensors can be effectively used for in-situ composite damage detection of delamination, voids, fractures, and rips. Keywords: Damage Detection, Composites, Integrated Vehicle Health Monitoring (IVHM), Aviation Safety, SansEC Sensors

Dudley, Kenneth L.↗

Blackstart and Fault Ride-Through Capability of DFIG-Based Wind Turbines

Grid-forming wind turbines must be able to re-energize transmission branches, motor loads, unbalanced loads, and power electronics loads following a blackout. Further, they must ride through faults that can arise during restoration. To tackle these challenges, this paper sets forth a grid-forming control strategy for wind turbines using doubly-fed induction generators (DFIGs). In particular, a special set of feedforward control loops are engineered to mitigate the impacts of restoration transients as well as symmetrical and asymmetrical faults on the regulation of DFIG rotor currents and stator voltages. This paper also leverages two-axis anti-windup regulators to bound two-axis voltage and current commands within ratings. As a result, the controller performance is demonstrated via a high-fidelity simulation model of a notional wind-dominant grid.

17 WIND ENERGY↗

Bounded Universal Droop Control to Enable the Operation of Power Inverters Under Some Abnormal Conditions and Maintain Voltage and Frequency Within Predetermined Ranges

The universal droop control (UDC) can be applied to power inverters having an impedance angle between -pi/2 rad and pi/2 rad to achieve voltage and frequency regulation and accurate proportional power sharing without the need of knowing the type or value of impedance. However, there is an increasing need for voltage and frequency regulation within predetermined ranges even under some abnormal conditions, such as overloading, sensor faults, and large set-point changes, etc. In this paper, a bounded nonlinear dynamics is introduced into the UDC to ensure that the voltage and frequency can always stay within predetermined ranges under normal and some abnormal conditions, up to hardware limits when current protection needs to be triggered. As a result, the proposed controller can extend the operational range of power inverters in terms of voltage and frequency regulation to cover different scenarios. More importantly, the ranges for both voltage and frequency can be chosen independently from each other. Since the original structure of the UDC is kept in the proposed controller, the properties of the UDC, such as without the need of knowing the type or value of impedance, are well maintained. Furthermore, the closed-loop stability of the system is established via the Lyapunov method. Extensive simulation and experimental results are presented to validate the effectiveness of the proposed controller.

14 SOLAR ENERGY↗

S-band Smallsat InSAR Constellation for Surface Deformation Science

Surface deformation studies using repeat-pass interferometric SAR have evolved into a powerful tool for geophysicists studying earthquake fault zones, volcanoes, ice sheet motion, and subterranean aquifers. Longer wavelengths (S-Band and L-Band) are preferred because they do not decorrelate as quickly as shorter wavelengths. Rapid revisit (1-3 days) is preferred because it allows the study of these phenomena at the timescales at which they commonly occur. Global access on such timescales is also required. Vector surface deformation measurements, taken from more than one direction, are a desired feature. This paper describes the conceptual architecture of a longer wave length, Smallsat SAR constellation of up to 12 satellites for rapid revisit surface deformation studies. The key to making such a constellation affordable is to lower launch costs, spacecraft costs, and instrument (SAR) costs. The first two objectives can be achieved using an ESPA-ring class, or Smallsat spacecraft. The third objective requires a SAR instrument sized to fit the mass and volume constraints imposed by such a spacecraft. Current state-of-the-art in miniaturization of electronics means that the radar transmit, receive and data handling functions can easily be implemented in a compact, low mass solution. The most significant challenge in designing a SAR to fit the Smallsat paradigm is in the dimensions of the antenna. The antenna sizing problem is addressed by adopting a smaller antenna than allowed by conventional SAR design rules. The baseline antenna design is simple, requiring no electronic beam-steering or beam-forming capability. Both reflectarray and microstrip patch antenna solutions are considered. The antenna structure is dual-purpose, to limit the overall system mass, with solar panels on the backplane providing power for the radar and spacecraft. The proposed solution easily accommodates radar squint angles of +/-30 degrees for repeat-pass interferometry measurements from multiple direct

Freeman, Anthony↗

Distortion and regulation characterization of a Mapham inverter

Output-voltage total harmonic distortion (THD) of a 20-kHz, 6-kVA Mapham resonant inverter is characterized as a function of its switching-to-resonant frequency ratio, f(s)/f(r), using the EASY5 Engineering Analysis System. EASY5 circuit simulation results are compared with hardware test results to verify the accuracy of the simulations. The effects of load on the THD versus f(s)/f(r) is investigated for resistive, leading, and lagging power factor load impedances. The effect of the series output capacitor on the Mapham inverter output-voltage distortion and inherent load regulation is characterized under loads of various power factors and magnitudes. An optimum series capacitor value which improves the inherent load regulation to better than 3 percent is identified. The optimum series capacitor value is different from the value predicted from a modeled frequency domain analysis. An explanation is proposed which takes into account the conduction overlap in the inductor pairs during steady-state inverter operation, which decreases the effective inductance of a Mapham inverter. A fault protection and current limit method is discussed which allows the Mapham inverter to operate into a short circuit, even when the inverter resonant circuit becomes overdamped.

Sundberg, Richard C.↗

Control of Wind Turbines: Past, Present, and Future

We review the objectives and techniques used in the control of horizontal axis wind turbines at the individual turbine level, where controls are applied to the turbine blade pitch and generator. The turbine system is modeled as a flexible structure operating in the presence of turbulent wind disturbances. Some overview of the various stages of turbine operation and control strategies used to maximize energy capture in below rated wind speeds is given, but emphasis is on control to alleviate loads when the turbine is operating at maximum power. After reviewing basic turbine control objectives, we provide an overview of the common basic linear control approaches and then describe more advanced control architectures and why they may provide significant advantages.

17 WIND ENERGY↗

Characterizing the Benefits of Seismic Isolation of Nuclear Structures in Terms of Reduced Risk and Cost

Seismic isolation is a mature technology that has been implemented in many civil structures, including buildings, bridges, liquid natural gas tanks, and off shore oil platforms, both in the United States and other countries, to mitigate the damaging effects of earthquakes. Seismic isolation has also been used in nuclear structures in France and South Africa, but not yet in the United States: neither in the Department of Energy facilities nor in commercial nuclear power plants (NPPs). This is primarily due to a lack of guidelines, codes and standards for the analysis, design and construction specific to seismically isolated nuclear structures. However, seismic isolation of nuclear structures has seen increased research interest in the recent years and the recently published national consensus standard, America Society of Civil Engineers (ASCE) Standard 4-16 'Seismic analysis of safety related nuclear structures', now incorporates language and commentary (Chapter 12) for seismically isolating surface or near-surface-mounted nuclear facilities, including NPPs. Seismic isolation substantially reduces horizontal seismic loads (demands) on structures, systems, and components. Reduction in demand results in four potential benefits: (1) economic: reduction in capital cost, (2) increased safety: reduction in the mean annual frequency of unacceptable performance, (3) insurance: protection against increases in the known seismic hazard after construction by minimizing the effort to re-qualify and re-certify structures, systems and components, and (4) recertification: the opportunity to certify an existing NPP design for a region of higher seismic hazard. Item (2) above, an increase in safety (reduction of seismic risk), was explored in Huang et al., wherein it was demonstrated that the implementation of seismic isolation reduced seismic risk in nuclear power plant structures. Studies that assess item (1) have not been performed although the use of isolation may lead to large reductions in the capital cost of safety-related nuclear facilities. Funding provided by Nuclear Safety Research and Development in the Department of Energy (DOE) allowed the authors to develop a framework for assessing the economic benefits and reductions in seismic risk afforded by the use of seismic (base) isolation. The framework includes probabilistic risk assessment and estimation of overnight capital costs (OCC's) of a sample generic DOE nuclear facility (GDNF). The project is documented in detail in Bolisetti et al. and Yu et al., and key results are presented here. The GDNF considered in this study is based on a facility constructed at the Idaho National Laboratory. The GDNF is a two-story reinforced concrete building with an embedded basemat and is founded on soft rock at the boundary of Site Class B and Site Class C (B/C boundary) as characterized by ASCE/SEI Standard 7. The GDNF is assumed to handle radiological materials, and its structure, systems and components (SSC's) are designed to effectively confine these materials in the event of an internal failure. The GDNF is populated with components that are generic to safety-related nuclear structures. A single system, which is intended to confine a loss of materials-at-risk (MAR) to the interior of the structure, is chosen for this study. Accordingly, a hypothetical event tree and fault tree are assumed for risk assessment. The isolation system for the GDNF is designed per Chapter 12 of ASCE/SEI 4-16 but is not optimized. The isolation system consists of 38 lead rubber bearings installed in one horizontal plane below the basemat. Details of the GDNF, including the SSC's, event tree and fault tree, and isolation system, are presented in the project report and Yu et al.. This study includes seismic risk assessment and cost estimation for four cases: (1) the GDNF is located at a site of low to moderate seismic hazard and is constructed on a conventional (non-isolated) foundation; (2) the GDNF is located at the same site as case 1, but is seismically isolated; (3) the GDNF is located at a site of high seismic hazard and is constructed on a conventional foundation; and (4) the GDNF is located at the same site of high seismic hazard as case 3, but is seismically isolated. In this study, the DOE site at Idaho National Laboratory (INL) is chosen as the low to moderate seismic hazard site for cases 1 and 2, and the Los Alamos National Laboratory (LANL) is chosen as the high seismic hazard site for cases 3 and 4.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Background Information on the Protection Requirements in IEEE Std 1547-2018

As the DER penetration level has risen significantly in recent times, parameter settings and configuration of installed DERs are having direct impact on local electric distribution utilities as well as bulk power systems during normal and abnormal grid conditions. On the other hand, all grid-connected DERs in the United States of America must conform to the interconnection requirements prescribed in the IEEE Std 1547-2018. Because of these reasons, it is crucial to understand the expected DER performance during abnormal grid conditions considering the requirements of the IEEE Std 1547-2018. The aim of this document is twofold: (1) to summarize requirements in IEEE Std 1547-2018 having direct implications in distribution network protection, and (2) to provide the reader with knowledge and information that will be required for users to apply the requirements specified. Since the focus of this document is on distribution network protection in the presence of DERs, it is assumed that the readers have basic understanding of distribution network protection as well as working principles of DERs. This document starts with a brief introduction on protection systems for distribution network followed by a discussion on the impact of DER on the protection systems. Current practices to provide network protection in the presence of DER is briefly discussed. The document then explores the DER performance requirements in IEEE Std. 1547-2018; especially on those related to distribution network protection. Section 6.1 in IEEE Std. 1547-2018 provides an overview of capabilities and control requirements for DER under abnormal operating conditions. This section also introduces abnormal operating performance categories I, II, III. The DER response to various types of faults and grid conditions such as short-circuit faults and open phase conditions are discussed in section 6.2 in the standard while requirements for coordination with the Area EPS reclosing scheme are provided in section 6.3. Section 6.4 in the IEEE Std 1547-2018 specifies requirements for mandatory voltage tripping and ride-through requirements during low and high voltage disturbances and section 6.5 specifies similar requirements for low and high frequency disturbances. IEEE Std. 1547 requires that the conformance of the DERs to IEEE Std 1547-2018 requirements should be verified in accordance with IEEE Std. 1547. 1. There are several parameters and settings of DERs that need to be properly selected for reliable operation during abnormal grid condition while applying the requirements of IEEE Std 1547-2018. Key decisions for proper selections of parameter and settings are: 1. Determination of required DER abnormal operating performance category, 2. Determination of DER response (shall trip) to abnormal voltages and 3. Determination of DER response (shall trip) to abnormal frequency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distortion and regulation characterization of a Mapham inverter

Output voltage Total Harmonic Distortion (THD) of a 20kHz, 6kVA Mapham resonant inverter is characterized as a function of its switching-to-resonant frequency ratio, f sub s/f sub r, using the EASY5 engineering analysis system. EASY5 circuit simulation results are compared with hardware test results to verify the accuracy of the simulations. The effects of load on the THD versus f sub s/f sub r ratio is investigated for resistive, leading, and lagging power factor load impedances. The effect of the series output capacitor on the Mapham inverter output voltage distortion and inherent load regulation is characterized under loads of various power factors and magnitudes. An optimum series capacitor value which improves the inherent load regulation to better than 3 percent is identified. The optimum series capacitor value is different than the value predicted from a modeled frequency domain analysis. An explanation is proposed which takes into account the conduction overlap in the inductor pairs during steady-state inverter operation, which decreases the effective inductance of a Mapham inverter. A fault protection and current limit method is discussed which allows the Mapham inverter to operate into a short circuit, even when the inverter resonant circuit becomes overdamped.

Sundberg, Richard C.↗

Separators - Technology review: Ceramic based separators for secondary batteries

Besides a continuous increase of the worldwide use of electricity, the electric energy storage technology market is a growing sector. At the latest since the German energy transition ('Energiewende') was announced, technological solutions for the storage of renewable energy have been intensively studied. Storage technologies in various forms are commercially available. A widespread technology is the electrochemical cell. Here the cost per kWh, e. g. determined by energy density, production process and cycle life, is of main interest. Commonly, an electrochemical cell consists of an anode and a cathode that are separated by an ion permeable or ion conductive membrane - the separator - as one of the main components. Many applications use polymeric separators whose pores are filled with liquid electrolyte, providing high power densities. However, problems arise from different failure mechanisms during cell operation, which can affect the integrity and functionality of these separators. In the case of excessive heating or mechanical damage, the polymeric separators become an incalculable security risk. Furthermore, the growth of metallic dendrites between the electrodes leads to unwanted short circuits. In order to minimize these risks, temperature stable and non-flammable ceramic particles can be added, forming so-called composite separators. Full ceramic separators, in turn, are currently commercially used only for high-temperature operation systems, due to their comparably low ion conductivity at room temperature. However, as security and lifetime demands increase, these materials turn into focus also for future room temperature applications. Hence, growing research effort is being spent on the improvement of the ion conductivity of these ceramic solid electrolyte materials, acting as separator and electrolyte at the same time. Starting with a short overview of available separator technologies and the separator market, this review focuses on ceramic-based separators. Two prominent examples, the lithium-ion and sodium-sulfur battery, are described to show the current stage of development. New routes are presented as promising technologies for safe and long-life electrochemical storage cells.

25 ENERGY STORAGE↗

Optimal Allocation of Dynamic Var Sources Using the Voronoi Diagram Method Integrating Linear Programing

Dynamic reactive power (var) sources can effectively mitigate fault-induced delayed voltage recovery (FIDVR) issues. This paper optimizes the sizes of dynamic var sources at given locations against FIDVR issues under severe contingencies. First, the geometric characteristics about the non-convex solution space of this problem are studied. Accordingly, a Voronoi diagram approach integrating linear programming (LP) is proposed, which disperses a number of sample points of potential solutions in the searching space to construct a Voronoi diagram blending the local cost functions over the entire space by Barycentric interpolation in Voronoi regions. New sample points are then recursively added, including the tentative optimal point using LP, the most depopulated area point ensuring global fidelity, and the connecting point, until the stopping criterion is met. The new approach is demonstrated in detail on the WSCC 9-bus system. A case study on the NPCC 140-bus system also validates that the proposed approach can effectively estimate the boundary and the geometry of the feasible solution region in the searching space and find the optimal solution.

barycentric interpolation↗

Digital Grid Twin–Direct Communication Scheme Test Bed for Assessing Relay-to-Relay Radio Antenna and Optical Fiber Performance and Misoperations

This study introduces a novel “Digital Grid Twin–Direct Communication Scheme” test bed. This advanced platform evaluates point-to-point communication between transmitter and receiver relays with optical fiber and radio omnidirectional antenna systems, implemented at the Advanced Protection lab in the Grid Research Innovation and Development Center at Oak Ridge National Laboratory. The increased diversity of energy sources has led to more protective relay misoperations. In North America, microgrid protection schemes now use point-to-point communication along distribution lines between relays to implement advanced logic in nonradial grids that include both high- and low-inertia generators. This trend challenges utilities to minimize misoperations while ensuring rapid fault clearance and accurate selectivity coordination between primary and backup relays. This study assesses relay-to-relay communication schemes by introducing an advanced testing platform based on a digital grid twin protection test bed using a synchronized time source system. The platform evaluates the communication system using radio antennas or optical fiber links by integrating protective relays that operate breakers within the digital twin and record relay events and communication signals. In the experiments, transmitter and receiver relays were configured with inverse time overcurrent and breaker trip detection logic to assess the total time of the communication protection schemes based on the sum of the relay protection element operating time, radio latency, propagation delay, baud rate delay, and relay processing time. These delays were derived from recorded relay events and communication signals from the interface of a real-time simulator set as a digital grid twin. The test bed successfully simulated various electrical faults along a distribution line while ensuring effective and reliable point-to-point communication between transmitter and receiver relays. The radio antenna communication system exhibited latency because of the radio. This latency depends on the baud rate setting and type of radio application; in general, the higher the baud rate, the lower the radio latency. The measured radio latency (for Mirrored Bits with an encryption card at 9,600 bps) was about 9–10 ms. Additionally, calculated propagation delay per mile for radio antennas and optical fiber was 5.36 µs/mi and 8.04 µs/mi, respectively. Optical fiber communication did not demonstrate radio latency. Instead, the protection element operating time depends mainly on the protection logic function set in the relay, and the relay processing time depends on the processing rate of the relay in samples per power system cycle.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utility Experience with Inverter Based Resource Impacts on Transmission Protection

High penetration of inverter-based resources (IBR) can adversely affect the transmission protection schemes in the area. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems because the existing system has been designed based on the fault current response of conventional rotating-machine-based generators. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. It includes a broad review of all challenges that system protection has experienced so far with high penetration of IBRs. Key issues have been identified based on a survey of different utility protection engineers. Finally, fault event recordings are shown to demonstrate some actual cases of mis-operations of relays near IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nonlinear Time Domain Seismic Soil-Structure Interaction (SSI) Deep Soil Site Methodology Development

Currently the Department of Energy (DOE) and the nuclear industry perform seismic soil-structure interaction (SSI) analysis using equivalent linear numerical analysis tools. For lower levels of ground motion, these tools should produce reasonable in-structure response values for evaluation of existing and new facilities. For larger levels of ground motion these tools likely overestimate the in-structure response (and therefore structural demand) since they do not consider geometric nonlinearities (such as gaping and sliding between the soil and structure) and are limited in the ability to model nonlinear soil behavior. The current equivalent linear SSI (SASSI) analysis approach either joins the soil and structure together in both tension and compression or releases the soil from the structure for both tension and compression. It also makes linear approximations for material nonlinearities and generalizes energy absorption with viscous damping. This produces the potential for inaccurately establishing where the structural concerns exist and/or inaccurately establishing the amplitude of the in-structure responses. Seismic hazard curves at nuclear facilities have continued to increase over the years as more information has been developed on seismic sources (i.e. faults), additional information gathered on seismic events, and additional research performed to determine local site effects. Seismic hazard curves are used to develop design basis earthquakes (DBE) that are used to evaluate nuclear facility response. As the seismic hazard curves increase, the input ground motions (DBE’s) used to numerically evaluation nuclear facility response increase causing larger in-structure response. As ground motions increase so does the importance of including nonlinear effects in numerical SSI models. To include material nonlinearity in the soil and geometric nonlinearity using contact (gaping and sliding) it is necessary to develop a nonlinear time domain methodology. This methodology will be known as, NonLinear Soil-Structure Interaction (NLSSI). In general NLSSI analysis should provide a more accurate representation of the seismic demands on nuclear facilities their systems and components. INL, in collaboration with a Nuclear Power Plant Vender (NPP-V), will develop a generic Nuclear Power Plant (NPP) structural design to be used in development of the methodology and for comparison with SASSI. This generic NPP design has been evaluated for the INL soil site because of the ease of access and quality of the site specific data. It is now being evaluated for a second site at Vogtle which is located approximately 15 miles East-Northeast of Waynesboro, Georgia and adjacent to Savanna River. The Vogtle site consists of many soil layers spanning down to a depth of 1058 feet. The reason that two soil sites are chosen is to demonstrate the methodology across multiple soil sites. The project will drive the models (soil and structure) using successively increasing acceleration time histories with amplitudes. The models will be run in time domain codes such as ABAQUS, LS-DYNA, and/or ESSI and compared with the same models run in SASSI. The project is focused on developing and documenting a method for performing time domain, non-linear seismic soil structure interaction (SSI) analysis. Development of this method will provide the Department of Energy (DOE) and industry with another tool to perform seismic SSI analysis.

58 GEOSCIENCES↗