Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Water-Rock Interactions in Outer Solar System Bodies: Evidence from the Coordinated Analysis of Interplanetary Dust

NASA has an ongoing program of collecting interplanetary dust particles (IDPs) in the stratosphere using high altitude research aircraft. The collected IDPs are derived from asteroids and comets and here we report studies of a subset of hydrated IDPs rich in carbonaceous matter that are proposed to have a cometary origin. Our studies are aimed at understanding the evolution of oxygen reservoirs in the Solar System and their interaction with cometary minerals and organic matter. The small size (<20 μm) and fragility of these IDPs present a number of analytical challenges. We have pioneered techniques for performing chemical, mineralogical, isotopic, and spectroscopic measurements on the same sample in a carefully coordinated sequence. Coordinated analyses of nanogram-size samples is made possible by several delicate sample preparation techniques. To avoid organic contamination, we embed IDPs in elemental sulfur and use ultramicrotomy to partly section the particles (the first few micrometers). Multiple thin sections (50-70 nm thick) are placed on different substrates depending on the analysis technique. We use a JEOL 2500SE scanning, transmission electron microscope (STEM) to determine the mineralogy, microstructure, and elemental compositions of constituent minerals in the thin sections through a combination of high resolution imaging, electron diffraction, quantitative energy-dispersive x-ray mapping, and electron energy-loss spectroscopy. Following the STEM analyses, we use a NanoSIMS 50L for high spatial resolution isotopic measurements of H, C, N, and O to search for presolar grains and to understand the origin of the indigenous organic matter. The isotopic analyses are performed on the same sections analyzed in the STEM in order to correlate isotopic properties with the elemental and mineralogical data. We reserve other thin sections for non-destructive analyses utilizing synchrotron-based techniques including Fourier-transform infrared (FTIR) micro-spectroscopy and X-ray absorption near-edge structure (XANES) analyses, especially for functional group analysis of organic matter in the particles. The remainder of the IDP is extracted from the sulfur bead that was used for microtomy and is pressed into Au foil for quantitative analysis (including light elements) using a JEOL 8530F field emission electron probe microanalyzer (EPMA). After the EPMA measurements, high precision oxygen isotopic analyses are obtained using Cameca IMS1270/1290 instruments at UCLA. The hydrated IDPs in this study are dominated by saponitic clays, with minor magnetite, carbonate and abundant organic matter. The remarkable oxygen isotopic compositions, high carbon contents, and the abundance of isotopically anomalous organic matter, together suggest that the high carbon, hydrated IDPs are derived from primitive sources not yet represented in meteorite collections such as outer main belt P- and D-type asteroids or comets.

Keller, Lindsay P.↗

Calibration analysis for a multi-channel infrared scanning radiometer

A procedure for calibrating an infrared scanning spectroradiometer by a computerized parametric error analysis technique was developed. The uncertainties in the radiometric measurements of scene radiance and (for the case of a blackbody scene) temperature due to possible uncertainties in the calibration target temperature, calibration target emissivity, and instrument temperature were calculated for a range of uncertainty levels in the parameters, as well as for a gamut of scent temperatures corresponding to a given spectral channel. This technique is applicable to the radiometric calibration of any infrared radiometer. It was applied specifically to the Cloud-Top Scanning (C.T.S) Radiometer, a three-channel instrument designed for aircraftborne cloud radiance measurements in the 6.75 and 11.5 micron thermal emission spectral regions.

Walden, H.↗

Scanning Seebeck Coefficient Measurement System for Homogeneity Characterization of Bulk and Thin-Film Thermoelectric Materials

Larger-scale production of thermoelectric materials is necessary when mass-producing thermoelectric devices at industrial level. Certain fabrication techniques can create inhomogeneity in the material through composition and doping fluctuations throughout the sample, causing local variations in thermoelectric properties. Some variations are in the range of sub-millimeter scale or larger but may be difficult to detect by traditional materials characterization techniques such as x-ray diffraction or scanning electron microscopy when the chemical variation is small but the doping variation, which strongly affects thermoelectric performance, is large. In this paper, a scanning apparatus to directly detect local variations of Seebeck coefficient on both bulk and thin-film samples is used. Results have shown that this technique can be utilized for detection of defective regions, as well as phase separation in the 100-m range or larger.

Iwanaga, S↗

Structural, electrical and dielectric properties of spinel nickel ferrite prepared by soft mechanochemical synthesis

Graphical abstract: - Highlights: • Sintered NiFe{sub 2}O{sub 4} was prepared by a soft mechanochemical route from mixture powders. • XRD and Raman measurements indicate that the prepared samples have spinel structure. • The activation energy ΔE are 0.653 and 0.452 eV for NiFe{sub 2}O{sub 4} samples. • Ferrite from Ni(OH){sub 2}/Fe{sub 2}O{sub 3} has lower DC conductivity than from Ni(OH){sub 2}/Fe(OH){sub 3} powders. • The values of dielectric constant of samples NiFe{sub 2}O{sub 4} are 70 and 200, respectively. - Abstract: Nickel ferrite, NiFe{sub 2}O{sub 4} was prepared by a soft mechanochemical route from a mixture of (1) Ni(OH){sub 2} and α-Fe{sub 2}O{sub 3} and (2) Ni(OH){sub 2} and Fe(OH){sub 3} powders in a planetary ball mill for 25 h. The powder samples were sintered at 1100 °C for 2 h and were characterized by X-ray diffraction (XRD), Raman spectroscopy and scanning electron microscopy (SEM). Impedance spectroscopy techniques were used to study the effect of grain and grain boundary on the electrical properties of the prepared samples. A difference in dielectric constant (ε) and dielectric loss tangent (tan δ) of NiFe{sub 2}O{sub 4} samples obtained by the same methods but starting from different initial components was observed.

36 MATERIALS SCIENCE↗

Volumetric modulated arc radiotherapy for esophageal cancer

A treatment planning study was performed to evaluate the performance of volumetric arc modulation with RapidArc (RA) against 3D conformal radiation therapy (3D-CRT) and conventional intensity-modulated radiation therapy (IMRT) techniques for esophageal cancer. Computed tomgraphy scans of 10 patients were included in the study. 3D-CRT, 4-field IMRT, and single-arc and double-arc RA plans were generated with the aim to spare organs at risk (OAR) and healthy tissue while enforcing highly conformal target coverage. The planning objective was to deliver 54 Gy to the planning target volume (PTV) in 30 fractions. Plans were evaluated based on target conformity and dose-volume histograms of organs at risk (lung, spinal cord, and heart). The monitor unit (MU) and treatment delivery time were also evaluated to measure the treatment efficiency. The IMRT plan improves target conformity and spares OAR when compared with 3D-CRT. Target conformity improved with RA plans compared with IMRT. The mean lung dose was similar in all techniques. However, RA plans showed a reduction in the volume of the lung irradiated at V{sub 20Gy} and V{sub 30Gy} dose levels (range, 4.62-17.98%) compared with IMRT plans. The mean dose and D{sub 35%} of heart for the RA plans were better than the IMRT by 0.5-5.8%. Mean V{sub 10Gy} and integral dose to healthy tissue were almost similar in all techniques. But RA plans resulted in a reduced low-level dose bath (15-20 Gy) in the range of 14-16% compared with IMRT plans. The average MU needed to deliver the prescribed dose by RA technique was reduced by 20-25% compared with IMRT technique. The preliminary study on RA for esophageal cancers showed improvements in sparing OAR and healthy tissue with reduced beam-on time, whereas only double-arc RA offered improved target coverage compared with IMRT and 3D-CRT plans.

61 RADIATION PROTECTION AND DOSIMETRY↗

Direct measurement of the static and transient magneto-optical permittivity of cobalt across the entire M -edge in reflection geometry by use of polarization scanning

The microscopic state of a magnetic material is characterized by its resonant magneto-optical response through the off-diagonal dielectric tensor component ε xy . However, the measurement of the full complex ε xy in the extreme ultraviolet spectral region covering the M absorption edges of 3d ferromagnets is challenging due to the need for either a careful polarization analysis, which is complicated by a lack of efficient polarization analyzers, or scanning the angle of incidence in fine steps. Here, we propose and demonstrate a technique to extract the complex resonant permittivity ε xy simply by scanning the polarization angle of linearly polarized high harmonics to measure the magneto-optical asymmetry in reflection geometry. Because this technique is more practical and faster to experimentally implement than previous approaches, we can directly measure the full time evolution of ε xy (t) during laser-induced demagnetization across the entire M 2,3 absorption edge of cobalt with femtosecond time resolution. We find that for polycrystalline Co films on an insulating substrate, the changes in ε xy are uniform throughout the spectrum, to within our experimental precision. This result suggests that, in the regime of strong demagnetization, the ultrafast demagnetization response is primarily dominated by magnon generation. Here, we estimate the contribution of exchange-splitting reduction to the ultrafast demagnetization process to be no more than 25%.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Develop Accurate Techniques for Passive SiC Temperature Monitoring of Miniature Samples for Cross-Cutting Applications

Passive thermometry is critically important because most fuels and materials irradiation experiments are not instrumented, and it is necessary to understand the irradiation temperature to properly interpret any post-irradiation examination data, including evolving properties and/or microstructures. The standard passive thermometry approach uses continuous dilatometry to evaluate changes in the instantaneous coefficient of thermal expansion during post-irradiation thermal annealing. This approach has limitations in terms of sample size (minimum length requirements) and the maximum irradiation temperature that can be accurately determined, which is limited by the reduced swelling (and therefore recovery) following higher temperature irradiation and limitations on the furnaces used with push-rod dilatometers. This work evaluates two new proposed techniques for post-irradiation evaluation of passive SiC temperature monitors: differential scanning calorimetry (DSC) and Raman spectroscopy. DSC is an extremely sensitive technique that can be used for any specimen geometry and is capable of higher temperature operation. Raman spectroscopy is similar in that it is a surface technique capable of examining extremely small samples (submillimeter), can be used with a heated stage up to 1,500°C (planned for future work), and is capable of mapping local irradiation temperatures throughout a sample. Existing SiC samples that were previously irradiated over a wide range of temperatures were cut into multiple pieces to allow for annealing studies using multiple different techniques: dilatometry, DSC, and Raman spectroscopy. This approach mitigates the concern that samples analyzed using one technique may have a slightly different irradiation history than those analyzed using a different technique. Recovery was clearly observed during annealing using both DSC and dilatometry. In some cases, a direct comparison could not be made due to some of the DSC runs accidentally including material from multiple specimens and issues with using an alternative DSC sample holder for the highest temperature annealing studies. Nevertheless, one trend was clear: the DSC runs resulted in higher irradiation temperatures compared to those of the dilatometry runs. Part of this could be attributed to the higher temperature ramp rates used during the DSC runs, which are often preferred to reduce noise in the measurements. By comparison, dilatometry has previously been shown to produce better data at lower ramp rates. Future work should further investigate the ideal ramp rate for both techniques to produce consistent results. Additional work should evaluate the best holder material to use for DSC runs exceeding 1,000°C to provide reliable data while preventing interactions between SiC and the holder.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Controlling atomistic processes on Pb films via quantum size effects and lattice rotation

The two main techniques used to record the data in this dissertation were Spot Profile Analysis - Low Energy Electron Diffraction (SPA-LEED) and Scanning Tunneling Microscopy (STM). A specific data analysis technique for LEED data called G(S) curves is described in depth. G(S) curves can provide a great deal of structural information about the surface; including step heights, island size, and island separation. The effects of quantum size effects (QSE) on the diffusion and critical island sizes of Pb and In on Pb films are reported. Pb depositions on the 2D In phases {radical}3 and {radical}31 to see how the phases affect the Pb growth and its strong QSE are reported.

36 MATERIALS SCIENCE↗

Estimation of random bending strain using a scanning laser vibrometer

Results are presented which were obtained from vibration measurements at discrete locations on a randomly excited structure to estimate the power spectral density of bending strain. The technique is intended to be applied using a scanning laser vibrometer to allow a non-contacting measurement of random bending strain over the surface of a structure. The experimental setup is described along with the data analysis procedure. The results presented here indicate that the method is practical and can lead to reliable estimates.

Miles, R. N.↗

Break-up of Pt catalyst surfaces by high CO coverage

Stepped Platinum surfaces were found to undergo extensive and reversible restructuring when exposed to CO at pressures above 0.1 Torr. This radically new and previously unknown restructuring phenomenon, has important implications for Pt based catalytic reactions. Novel Scanning Tunneling Microscopy and Photoelectron Spectroscopy techniques operating under gaseous environments near ambient pressure and temperature revealed that as the CO surface coverage approaches 100percent, the originally flat terraces of stepped Pt crystals break up into nanometer size clusters. At room temperature the crystal surface reverts to its initial flat morphology after pumping away the gas phase CO. Density Functional Theory energy calculations provide a rationale for the observations whereby the creation of increased concentrations of low coordination Pt sites at the edges of the formed nanoclusters relieves the strong CO-CO repulsion in the highly compressed adsorbate film.

36 MATERIALS SCIENCE↗

Effect of Multi-Walled Carbon Nanotubes on Viscoelastic Properties of PP/Reed Flour Composites

The objective of this investigation was to evaluate the influence of multi-wall carbon nanotubes (MWCNTs) on the dynamic mechanical properties of polypropylene (PP)/reed flour (RF) composites. The experimental samples were prepared through the melt mixing of PP/RF at 50% weight ratios, with various amounts of MWCNTs (0, 1, 2, 3 and 5 phr) in a twin-screw extruder, then the samples made by injection molding. The amount of maleic anhydride grafted polypropylene (PP-g-MA) as a coupling agent was fixed at 2 phr for all formulations. Dynamic mechanical analysis (DMA) tests were carried out to investigate the viscoelastic behavior of nanocomposites. The dynamic mechanical properties such as storage modulus (Eʹ), loss modulus (Eʺ), and damping coefficient (tan δ) of nanocomposites were investigated in the temperature range of −80 to 160 °C at a step of 5 °C and frequency of 1 Hz. The morphology of the specimens was characterized using field emission scanning electron microscope (FE-SEM) technique. Results indicated that the storage modulus of samples was found to increase with incorporation of MWCNTs while damping properties registered a decrease, owing to the reinforcing effect of CNTs into the composites. Moreover, CNTs addition leads to a positive shift in glass transition temperature (T{sub g}), which is explained on the molecular mobility of the polymer chains behavior. Additionally, the minimum adhesion factor is related to samples containing 2 phr MWCNTs which provides the best interaction between polymer and fibers. FE-SEM micrographs showed a predominantly homogeneous CNTs distribution through the composites; however, some aggregates were observed at higher CNTs fractions.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Enhancing the local conductivity of Cu films using temperature-assisted agglomerated Cu nanostructures

We investigate the structural and electrical properties of Cu film and reveal their changes as a function of post-annealing temperature. Thermal annealing of a Cu film on a dielectric substrate can improve its crystallinity; however, high-temperature annealing also leads to a morphological transformation that hinders the precise measurement of electrical properties. The enhanced crystallinity of the Cu films is verified with x-ray diffraction as the annealing temperature increases. To examine the electrical properties of the Cu film after the dewetting processes, which promotes the formation of voids and agglomerations, we utilize both conventional micro four-point probe method as well as an advanced four-point probe scanning tunneling microscopy (4P-STM) technique to measure the conductance and evolution of the microscopic structural properties. We could eliminate a deceptive effect of voids with 4P-STM technique, and disclosed a significantly reduced resistivity (1.88 ± 0.07 µΩ∙cm) of Cu nanostructure after post-annealing at 700 °C. We unveiled impact of crystallinity and imperfections of Cu nanostructure, and discussed the critical role of the twin grain boundaries of single-crystalline Cu (1 1 1) on an Al 2 O 3 substrate. We anticipate that understanding the evolution of the structures and the enhanced electrical properties of the post-annealed Cu nanostructures would be important for nanoscale devices where Cu is used as an interconnecting material and could provide a new route to control the plasmonic applications.

36 MATERIALS SCIENCE↗

Characterization of free breathing patterns with 5D lung motion model

Purpose: To determine the quiet respiration breathing motion model parameters for lung cancer and nonlung cancer patients. Methods: 49 free breathing patient 4DCT image datasets (25 scans, cine mode) were collected with simultaneous quantitative spirometry. A cross-correlation registration technique was employed to track the lung tissue motion between scans. The registration results were applied to a lung motion model: X-vector=X-vector{sub 0}+{alpha}-vector{beta}-vector f, where X-vector is the position of a piece of tissue located at reference position X-vector{sub 0} during a reference breathing phase (zero tidal volume v, zero airflow f). {alpha}-vector is a parameter that characterizes the motion due to air filling (motion as a function of tidal volume v) and {beta}-vector is the parameter that accounts for the motion due to the imbalance of dynamical stress distributions during inspiration and exhalation that causes lung motion hysteresis (motion as a function of airflow f). The parameters {alpha}-vector and {beta}-vector together provide a quantitative characterization of breathing motion that inherently includes the complex hysteresis interplay. The {alpha}-vector and {beta}-vector distributions were examined for each patient to determine overall general patterns and interpatient pattern variations. Results: For 44 patients, the greatest values of |{alpha}-vector| were observed in the inferior and posterior lungs. For the rest of the patients, |{alpha}-vector| reached its maximum in the anterior lung in three patients and the lateral lung in two patients. The hysteresis motion {beta}-vector had greater variability, but for the majority of patients, |{beta}-vector| was largest in the lateral lungs. Conclusions: This is the first report of the three-dimensional breathing motion model parameters for a large cohort of patients. The model has the potential for noninvasively predicting lung motion. The majority of patients exhibited similar |{alpha}-vector| maps and the |{beta}-vector| maps showed greater interpatient variability. The motion parameter interpatient variability will inform our need for custom radiation therapy motion models. The utility of this model depends on the parameter stability over time, which is still under investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Portable Vibro-acoustic Testing System for In Situ Microstructure Characterization and Metrology

Portable Vibro-acoustic Testing System for In situ Microstructure Characterization and Metrology James A. Smith, Corrie I. Nichol Idaho National Laboratory, Idaho Falls ID Mostafa Fatemi, Mayo Clinic, Rochester MN There is a need in research reactors like the INL to inspect irradiated materials and structures. The goal of this work is to develop a portable scanning infrastructure for a material characterization technique called vibro-acoustography (VA) that has been developed by INL [1] for nuclear applications to characterize fuel, cladding materials, and structures. The proposed VA technology is based on ultrasound and acoustic waves; however, it provides information beyond what is available from the traditional ultrasound techniques and can expand the knowledge on nuclear material characterization and microstructure evolution. VA is a three-dimensional (3D) imaging modality based on ultrasound-stimulated acoustic emission. VA uses the force caused by the beating of two frequencies to generate an acoustic emission signal. Due to absorption or reflection, the energy density in the object at an acoustic focal point changes to produce a “radiation force.” This force locally vibrates the object, which results in an acoustic field that depends on the characteristics of the object at that point. This acoustic field is detected for every point in the object; the resulting data is used to make an image of the object’s mechanical properties. This technology is fundamentally different from traditional ultrasound imaging. More specifically, VA is: (a) based on the “radiation force,” a nonlinear phenomenon in sound propagation, and (b) sensitive to both high and low frequency dynamic responses of the object. The combination of these two response types provides information about characteristics of the object beyond what is possible by traditional ultrasound imaging. High spatial resolution is achieved, since the radiation force is localized to the focal point of the ultrasound beam. Low-frequency information, which is a representative of structural characteristics, is gained through the radiation force mechanism at a low (beat) frequency. This paper will report on the development of a portable scanning that can be set up to characterize materials and component in open water reactors and canals in situ. We will show some initial laboratory results of images generated by vibro-acoustics of surrogate fuel plates and graphite structures and discus the design of the portable system. 1. Smith, J. A., and Kunerth, D. C., “Vibro-acoustic Sensors for Materials Characterization and Related Methods and Systems,” Patent Application 13226280, 09/06/2011.

36 MATERIALS SCIENCE↗

Riley oxidation: A forgotten name reaction for synthesis of selenium nanoparticles

A simple wet chemical method, involving reaction of acetone with selenium dioxide, has been developed, to synthesize polyvinyl alcohol-stabilized selenium nanoparticles. The method is capable of producing nanoparticles in the size range of about 100-300 nm, under ambient conditions. The synthesized nanoparticles can be separated easily from the aqueous sols by a high-speed centrifuge, and can be re-dispersed in aqueous medium by a sonicator. The effect of concentrations of selenium dioxide, acetone and PVA on the size of the selenium nanoparticles has been studied. The size of the selenium nanoparticles has been found to increase with increase in the reaction time as well as the concentration of selenium dioxide, while it decreases with increase in the concentration of the stabilizer, PVA. The synthesized selenium nanoparticles have been characterized by UV-visible optical absorption spectroscopy, X-ray diffraction, energy dispersive X-ray analysis, differential scanning calorimetry, atomic force microscopy, scanning electron microscopy and transmission electron microscopy techniques.

36 MATERIALS SCIENCE↗

Revealing CO 2 dissociation pathways at vicinal copper (997) interfaces

Size- and shape-tailored copper (Cu) nanocrystals can offer vicinal planes for facile carbon dioxide (CO 2 ) activation. Despite extensive reactivity benchmarks, a correlation between CO 2 conversion and morphology structure has not yet been established at vicinal Cu interfaces. Herein, ambient pressure scanning tunneling microscopy reveals step-broken Cu nanocluster evolutions on the Cu(997) surface under 1 mbar CO 2 (g). The CO 2 dissociation reaction produces carbon monoxide (CO) adsorbate and atomic oxygen (O) at Cu step-edges, inducing complicated restructuring of the Cu atoms to compensate for increased surface chemical potential energy at ambient pressure. The CO molecules bound at under-coordinated Cu atoms contribute to the reversible Cu clustering with the pressure gap effect, whereas the dissociated oxygen leads to irreversible Cu faceting geometries. Synchrotron-based ambient pressure X-ray photoelectron spectroscopy identifies the chemical binding energy changes in CO-Cu complexes, which proves the characterized real-space evidence for the step-broken Cu nanoclusters under CO(g) environments. Our in situ surface observations provide a more realistic insight into Cu nanocatalyst designs for efficient CO 2 conversion to renewable energy sources during C 1 chemical reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Surface grain refinement of casting A380 aluminum alloy by ultrasonic-assisted surface mechanical grinding treatment

A novel surface processing technique, ultrasonic-assisted surface mechnical grinding treatment (U-SMGT), was proposed and applied to modify the surface micriostructure of the casting aluminum alloy (A380). Comprehensive post-process chracterization techniques including 3D profilometry, optical microscope, scanning electric microscopy (SEM), and electron backscatter diffraction (EBSD) were carried out to investigate the surface morphology and microstructure of the processed region (PR). It was found that a surface layer of grain refinement with a thickness of about 50 µm was formed. In the as-received base material (BM), large clusters of dendritic eutectic phase with a size of approximately 20 µm were isolated by α-Al matrix. Nano-indentation tests showed that hardness of the eutectic and α-Al in the as-received BM was 2.15 GPa and 1.2 GPa respectively. After U-SMGT, the large dendritic eutectic phase was broken down into much fine particles with an average size of 0.57 µm. These fine particles were uniformly distributed into the α-Al matrix. Nano-indentation measurement exhibited a hardness of 2.27 GPa within the processed region. The overall high hardness in the processed region is a result of the pinning effect of uniformly distributed fine dendrites and grain refinement of Al-matrix.

36 MATERIALS SCIENCE↗

Characterization of crystalline ceramic waste form

The research conducted in this work package is to collect data in support of future development of ceramic waste forms and to help develop the next generation high performance waste management technologies. This work package collaborates closely with the work conducted under “Ceramics - Savannah River National Laboratory (SRNL) - (FT-15SR030702)” and the NEUP project “Alternative High-Performance Ceramic Waste Forms” – Alfred University (AU) – (DE-AC07-05ID14517)”. The Los Alamos National Laboratory (LANL) is focusing on characterization and testing procedure on the reference crystalline ceramics to further develop the crystalline ceramic waste form to incorporate combined HLW raffinate stream and/or TRU stream from fuels fabrication processes. In Fiscal Year 2015, we are mainly working on cold crucible induction melter (CCIM) test multi-phase crystalline ceramic waste form samples and single phase hollandite materials. Various characterization techniques (including X-ray diffraction, transmission electron microscopy, scanning electron microscopy) were used to characterize CCIM samples. For the radiation stability test, in situ radiation techniques were employed to simulate self-radiation in waste form samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗