Search NASA⌕ Search

SEARCH · Search NASA

Results for “Signal Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Astrometric Microlensing by Primordial Black Holes with the Roman Space Telescope

Abstract Primordial black holes (PBHs) could explain some fraction of dark matter and shed light on many areas of early-Universe physics. Despite over half a century of research interest, a PBH population has so far eluded detection. The most competitive constraints on the fraction of dark matter comprised of PBHs ( f DM ) in the (10 −9 –10) M ⊙ mass ranges come from photometric microlensing and bound f DM ≲ 10 −2 –10 −1 . With the advent of the Roman Space Telescope with its submilliarcsecond astrometric capabilities and its planned Galactic Bulge Time Domain Survey (GBTDS), detecting astrometric microlensing signatures will become routine. Compared with photometric microlensing, astrometric microlensing signals are sensitive to different lens masses–distance configurations and contain different information, making it a complimentary lensing probe. At submilliarcsecond astrometric precision, astrometric microlensing signals are typically detectable at larger lens–source separations than photometric signals, suggesting a microlensing detection channel of pure astrometric events. We use a Galactic simulation to predict the number of detectable microlensing events during the GBTDS via this pure astrometric microlensing channel. Assuming an absolute astrometric precision floor for bright stars of 0.1 mas for the GBTDS, we find that the number of detectable events peaks at ≈10 3 f DM for a population of 1 M ⊙ PBHs and tapers to ≈10 f DM and ≈100 f DM at 10 −4 M ⊙ and 10 3 M ⊙ , respectively. Accounting for the distinguishability of PBHs from stellar lenses, we conclude the GBTDS will be sensitive to a PBH population at f DM down to ≈10 −1 –10 −3 for (10 −1 –10 2 ) M ⊙ likely yielding novel PBH constraints.

79 ASTRONOMY AND ASTROPHYSICS↗

Laser Wakefield Acceleration Driven by a CO2 Laser (STELLA-LW) - Final Report

The original goals of the Staged Electron Laser Acceleration – Laser Wakefield (STELLA-LW) program were to investigate two new methods for laser wakefield acceleration (LWFA). In pseudo-resonant LWFA (PR-LWFA), a laser pulse experiences nonlinear pulse steepening while traveling through the plasma. This steepening allows the laser pulse to generate wakefields even though the laser pulse length is too long for resonant LWFA to occur. For the conditions of this program, PR-LWFA requires a minimum laser peak power of 3 TW and a low plasma density (10^16 cm^-3). Seeded self-modulated LWFA (seeded SM-LWFA) combines LWFA with plasma wakefield acceleration (PWFA). An ultrashort (~100 fs) electron beam bunch acts as a seed in a plasma to form a wakefield via PWFA. This wakefield is subsequently amplified by the laser pulse through a self-modulated LWFA process. At least 1 TW laser power and, for a ~100-fs bunch, a plasma density ~10^17 cm^-3 are required. STELLA-LW was located on Beamline #1 at the Brookhaven National Laboratory (BNL) Accelerator Test Facility (ATF). The ATF TW CO2 laser served as the driving laser beam for both methods. For PR-LWFA, a single bunch was to probe the wakefield produced by the laser beam. For seeded SM-LWFA, the ATF linac would produce two bunches, where the first would be the seed and the second would be the witness. A chicane would compress the first bunch to enable it to generate wakefields via PWFA. The plasma source was a short-length, gas-filled capillary discharge with the laser beam tightly focused in the center of the capillary, i.e., no laser guiding was used, in order to obtain the needed laser intensity. During the course of the program, several major changes had to be made. First, the ATF could not complete the upgrade of the CO2 laser to the 3 TW peak power needed for the PR-LWFA experiment. Therefore, the PR-LWFA experiment had to be abandoned leaving only the seeded SM-LWFA experiment. Second, the ATF discovered that the chicane bifurcated the incoming bunch into two compressed bunches separated in time and energy. With the available equipment it was not possible to stop the bifurcation. In an attempt to still deliver a single compressed bunch to the experiment, a slit was used to block one of the bunches, but this also blocked any witness bunch. Third, the loss of the witness bunch meant a different method for detecting the effect of the laser beam on the wakefield had to be implemented. Hence, a coherent Thomson scattering (CTS) diagnostic was designed and assembled. Unfortunately, further tests with blocking one of the double-bunches showed that wakefield generation was too unstable and difficult to control for the seeded SM-LWFA experiment. Luckily, it was found that a fast-rising (~50 fs) bunch could be created along Beamline #2 that was capable of generating wakefields, did not use the chicane, and was more stable. Thus, as the fourth major change, the entire STELLA-LW apparatus, including the CTS diagnostic, was moved from Beamline #1 to Beamline #2. Because this move occurred near the end of the program, only a single 2-week run could be performed. During the run it was found the laser beam transmission through the capillary discharge was severely degraded when the plasma was on. This loss of transmission appeared to be due to defocusing of the laser beam probably caused by laser-induced ionization creating a lens effect inside the capillary. Defocusing could also cause laser light to strike the capillary wall, thereby producing ablation and localized changes in the plasma density. Any changes in the plasma density would disrupt the plasma resonance condition for the wakefield. It was also discovered after the run that the ATF laser was producing multiple output pulses. The leading pulse could have caused ionization that interfered with transmission of the following pulses. Worse yet, the peak power in each of the pulses was several times smaller than if all the pulse energy was in a single pulse. This meant each pulse had less than 1 TW power. Wakefield formation with no laser beam present was confirmed by observing energy loss of the fast-raising seed bunch passing through the capillary discharge. When the laser beam was sent into the plasma, no CTS signal was detected, probably due to defocusing of the laser light, changes in the plasma density due to laser-induced ionization, and insufficient peak power in the individual pulses. It is for these reasons we were not able to validate the seeded SM-LWFA predictions. In summary, the STELLA-LW experiment was not able to demonstrate seeded SM-LWFA or PR-LWFA primarily because of limitations of the ATF CO2 laser, both in its deliverable peak power and its ability to provide a single laser pulse.

43 PARTICLE ACCELERATORS↗

The footprints of visual attention in the Posner cueing paradigm revealed by classification images

In the Posner cueing paradigm, observers' performance in detecting a target is typically better in trials in which the target is present at the cued location than in trials in which the target appears at the uncued location. This effect can be explained in terms of a Bayesian observer where visual attention simply weights the information differently at the cued (attended) and uncued (unattended) locations without a change in the quality of processing at each location. Alternatively, it could also be explained in terms of visual attention changing the shape of the perceptual filter at the cued location. In this study, we use the classification image technique to compare the human perceptual filters at the cued and uncued locations in a contrast discrimination task. We did not find statistically significant differences between the shapes of the inferred perceptual filters across the two locations, nor did the observed differences account for the measured cueing effects in human observers. Instead, we found a difference in the magnitude of the classification images, supporting the idea that visual attention changes the weighting of information at the cued and uncued location, but does not change the quality of processing at each individual location.

Non-NASA Center↗

Revealing the Anion–Solvent Interaction for Ultralow Temperature Lithium Metal Batteries

Anion solvation in electrolytes can largely change the electrochemical performance of the electrolytes, yet has been rarely investigated. Herein, three anions of bis(trifluoromethanesulfonyl)imide (TFSI), bis(fluorosulfonyl)imide (FSI), and derived asymmetric (fluorosulfonyl)(trifluoro-methanesulfonyl)imide (FTFSI) are systematically examined in a weakly Li + cation solvating solvent of bis(3-fluoropropyl)ether (BFPE). In-situ liquid secondary ion mass spectrometry demonstrates that FTFSI - and FSI - anions are associated with BFPE solvent, while weak TFSI - /BFPE cluster signals are detected. Molecular modeling further reveals that the anion–solvent interaction is accompanied by the formation of H-bonding-like interactions. Further, anion solvation enhances the Li + cation transfer number and reduces the organic component in solid electrolyte interphase, which enhances the Li plating/stripping Coulombic efficiency at a low temperature of -30 °C from 42.4% in TFSI-based electrolytes to 98.7% in 1.5 m LiFTFSI and 97.9% in LiFSI-BFPE electrolytes. The anion–solvent interactions, especially asymmetric anion solvation also accelerate the Li + desolvation kinetics. The 1.5 m LiFTFSI-BFPE electrolyte with strong anion–solvent interaction enables LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811)||Li (20 µm) full cell with stable cyclability even under -40 °C, retaining over 92% of initial capacity (115 mAh g -1 , after 100 cycles). The anion–solvent interactions insights allow to rational design the electrolyte for lithium metal batteries and beyond to achieve high performance.

25 ENERGY STORAGE↗

The vast potential of exoplanet satellites for high-energy astrophysics

The photometric precision, monitoring baselines, and rapid, even sampling rates required by modern satellites designed for detecting the signal of transiting exoplanets are ideally suited to a large number of applications in high–energy astrophysics. I will exemplify this by discussing the results for active galactic nuclei from Kepler and summarizing other high–energy results from Kepler/K2. These precision instruments are currently underutilized for high–energy applications despite their great potential, due in part to complex systematics affecting the data. Here, I will summarize these effects and mitigation approaches, and conclude by discussing how the recently launched Transiting Exoplanet Survey Satellite mission will differ from Kepler /K2 in ways significant to the high–energy community.

79 ASTRONOMY AND ASTROPHYSICS↗

A comparison of pulsed and continuous lasers for high-temperature Raman measurements of anhydrite

Oxygen carrier particles (OCPs) serve as fuel oxidant in emerging chemical looping combustion systems. However, chemical looping combustion process optimization is hindered by the lack of online sensors for measurements of OCP oxidation states at temperatures up to 1,000 °C and pressures up to 10 atm. We are investigating Raman spectroscopy as a potential solution, as this technique is known for its ability to provide noninvasive, molecularly specific information in real time in a wide variety of applications. As a case study, Raman spectra from high–temperature (>1,000 °C) anhydrite, a potential OCP, are presented using pulsed and continuous wave excitation at 532 nm. When pulsed excitation is coupled with time–gated detection, background signal from thermal radiation can be significantly reduced from single pulse spectra, outperforming results using an ungated detector. Also, laser heating of the sample is not observed but laser–induced breakdown spectra increasingly appear with increasing temperature and pulse intensity. Compared with pulsed excitation, continuous wave excitation with longer acquisition time, offers higher signal to noise and avoids the risk for laser–induced breakdown spectra but demonstrates minor sample heating. Finally, the data demonstrate practical utility by (a) providing a calibration of anhydrite's ν 1 (1,017 cm –1 ) Raman temperature–dependent band position and by (b) providing estimates of temperature using the ratios of the Stokes/anti–Stokes ν 1 integrated intensities. Furthermore, these results demonstrate the first high–temperature, pulsed Raman spectra from anhydrite while evaluating challenges associated with high–temperature, Raman measurements of OCP materials in general.

20 FOSSIL-FUELED POWER PLANTS↗

Displaced lepton jet signatures from self-interacting dark matter bound states

We study self-interacting dark matter signatures at the Large Hadron Collider. A light dark photon, mediating dark matter self-interactions, can bind dark matter particles to form a bound state when they are produced via a heavy pseduoscalar in pp collisions. The bound state can further annihilate into a pair of boosted dark photons, which subsequently decay into charged leptons through a kinetic mixing portal, resulting in striking displaced lepton jet signals. After adapting the analysis used in the ATLAS experiment, we explore the reach of the model parameters at the 13 TeV run with an integrated luminosity of 300 fb -1 . For heavy dark matter, the displaced lepton jet searches can surpass traditional monojet signals in setting the lower bound on the pseduoscalar mass. If a positive signal is detected, we can probe the dark matter mass and the dark coupling constant after combining both the displaced lepton jet and monojet searches. We further show the CMS dimuon search can be sensitive to the final state radiation of the dark photon. Our results demonstrate terrestrial collider experiments complement astronomical observations of galaxies in the search of the self-interacting nature of dark matter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Polonium–lead extractions to determine the best method for the quantification of clean lead used in low-background radiation detectors

Very sensitive detectors are used for low-background applications including the detection of environmental radioactivity, double-beta decay, and dark matter. In order to reduce the background noise enough to utilize the sensitivity of these detectors, lead with little or no alpha activity is required to form the shielding. In the past, antiquity lead shielding was used for low-background detectors because lead’s most prominent alpha-emitting isotope, 210Pb, has a short half-life. The microelectronics industry is also greatly affected by alpha activity in lead and solder, and has begun producing “clean” lead for purchase. To quantify how clean the available lead is, 210Pb and, during procedural experiments, a 209Po tracer must be physically or chemically removed from the bulk lead. A reliable procedure for chemical separations that does not use large volumes of ultra-high-purity chemicals has not yet been established. Lead was dissolved and a known amount of 209Po tracer was added. The samples were put through each of two new procedures. The first procedure was based on complete dissolution of the lead followed by a column separation. The second method investigates the utility of a pre-separation step using precipitation of the lead prior to column separation. The resulting solutions were run through strontium resin columns from Eichrom Inc., a United States Transuranium and Uranium Registries (USTUR) electrodeposition procedure, and scheduled to be alpha counted for a minimum of three days. Though neither of the tested procedures had acceptable logistics for large scale implementation, later alpha counting will show which procedure is more promising for further development

Miley, Sarah M↗

Expression of cellular apoptosis susceptibility (CAS) in the human testis and testicular germ cell tumors

Testicular germ cell tumors are the most frequent malignancies found in men between 15 and 44 years old. Although cellular apoptosis susceptibility (CAS) was demonstrated to be upregulated in breast cancer and colon cancer, the expression of CAS in the human testis and testicular germ cell tumors remained elusive. In the present study, CAS-positive signals were detected in the normal testicular tissues, cancer adjacent normal testicular tissues, seminoma, yolk sac tumor, and teratoma. Interestingly, the expression level of CAS in testicular germ cell tumors (TGCTs) (but not seminoma) was significantly lower than that of human testicular tissues and cancer adjacent normal testicular tissues, suggesting that decreased CAS contributed to the progression of TGCTs. Notably, the expression of CAS in seminoma was significantly higher than that of in the non-seminomas, consistent with the results from TCGA database. Furthermore, the localization of CAS is mainly restricted in the nucleus in the lesions of normal human testicular tissue and cancer adjacent normal testicular tissue. Although the expression of CAS was not significantly different between normal testicular tissue and seminoma, CAS was more enriched in cytoplasm in seminoma compared to the normal, cancer adjacent tissue and other types of TGCTs. The current results demonstrated reduced expression of CAS in the human testicular germ cell tumors and the CAS translocation from the nuclear to cytoplasm in seminoma, thereby supporting a possible role in normal testis function and in the development of seminoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nuclear spectroscopy for in situ soil elemental analysis: Monte Carlo simulations

We developed a model to simulate a novel inelastic neutron scattering (INS) system for in situ non-destructive analysis of soil using standard Monte Carlo Neutron Photon (MCNP5a) transport code. The volumes from which 90%, 95%, and 99% of the total signal are detected were estimated to be 0.23 m{sup 3}, 0.37 m{sup 3}, and 0.79 m{sup 3}, respectively. Similarly, we assessed the instrument's sampling footprint and depths. In addition we discuss the impact of the carbon's depth distribution on sampled depth.

54 ENVIRONMENTAL SCIENCES↗

Single-molecule imaging at high fluorophore concentrations by local activation of dye

Single-molecule fluorescence microscopy is a powerful approach to observe biomolecular interactions with high spatial and temporal resolution. Detecting fluorescent signals from individual, labeled proteins above high levels of background fluorescence remains challenging, however. For this reason, the concentrations of labeled proteins in in vitro assays are often kept low compared to their in vivo concentrations. Here, we present a new fluorescence imaging technique by which single fluorescent molecules can be observed in real time at high, physiologically relevant concentrations. The technique requires a protein and its macromolecular substrate to be labeled each with a different fluorophore. Then, making use of short-distance energy-transfer mechanisms, the fluorescence from only those proteins bound to their substrate are selectively activated. This approach is demonstrated by labeling a DNA substrate with an intercalating stain, exciting the stain, and using energy transfer from the stain to activate the fluorescence of only those labeled DNA-binding proteins bound to the DNA. Such an experimental design allowed us to observe the sequence-independent interaction of Cy5-labeled interferon-inducible protein 16 (IFI16) with DNA and the sliding via one-dimensional diffusion of Cy5-labeled adenovirus protease (pVIc-AVP) on DNA in the presence of a background of hundreds of nM Cy5 fluorophore.

59 BASIC BIOLOGICAL SCIENCES↗

Sensitivity of geophysical techniques for monitoring secondary CO 2 storage plumes

For geologic carbon storage, the ability to detect secondary CO 2 plumes—defined as those CO 2 plumes accumulating outside the intended storage reservoir—is fundamental to preventing unexpected CO 2 migration into groundwater resources and for risk and liability management. Understanding the sensitivity of various geophysical methods to secondary plumes is crucial for designing cost-effective monitoring schemes. We use several modeling scenarios to demonstrate the process of assessing sensitivities and detection thresholds of three primary geophysical techniques—surface seismic, borehole-to-surface electromagnetic (EM), and surface and borehole gravity—for early detection of secondary CO 2 plumes in the post-injection phase. While seismic reflection methods are often considered in monitoring strategies to track the evolution of CO 2 plumes, they are also the most expensive. Due to cost considerations, especially for long-term post-injection monitoring, other techniques complement seismic monitoring when designing an adaptive monitoring network. Borehole-to-surface EM or surface gravity surveys are feasible for time-lapse monitoring of deep secondary CO 2 plumes. Furthermore, these surveys could be carried at intervals defined by site-specific conditions. If time-lapse EM and/or gravity surveys detect any signal responses beyond the expected change, it would trigger a need for the higher resolution seismic survey.

58 GEOSCIENCES↗

Structural Characterization of the Predominant Family of Histidine Kinase Sensor Domains

Histidine kinase (HK) receptors are used ubiquitously by bacteria to monitor environmental changes, and they are also prevalent in plants, fungi, and other protists. Typical HK receptors have an extracellular sensor portion that detects a signal, usually a chemical ligand, and an intracellular transmitter portion that includes both the kinase domain itself and the site for histidine phosphorylation. While kinase domains are highly conserved, sensor domains are diverse. HK receptors function as dimers, but the molecular mechanism for signal transduction across cell membranes remains obscure. In this study, eight crystal structures were determined from five sensor domains representative of the most populated family, family HK1, found in a bioinformatic analysis of predicted sensor domains from transmembrane HKs. Each structure contains an inserted repeat of PhoQ/DcuS/CitA (PDC) domains, and similarity between sequence and structure is correlated across these and other double-PDC sensor proteins. Three of the five sensors crystallize as dimers that appear to be physiologically relevant, and comparisons between ligated structures and apo-state structures provide insights into signal transmission. Some HK1 family proteins prove to be sensors for chemotaxis proteins or diguanylate cyclase receptors, implying a combinatorial molecular evolution.

59 BASIC BIOLOGICAL SCIENCES↗

Electrochemical and morphological studies of ionic polymer metal composites as stress sensors

Ionic polymer metal composites (IPMCs) are the backbone of a wide range of ionic devices. IPMC mechanoelectric sensors are advanced nanostructured transducers capable of converting mechanical strain into easily detectable electric signal. Such attribute is realized by ion mobilization in and through IPMC nanostructure. In this study we have investigated electrochemical and morphological characteristics of IPMCs by varying the morphology of their metal composite component (conductive network composite (CNC)). We have demonstrated the dependence of electrochemical properties on CNC nanostructure as well as mechanoelectrical performance of IPMC sensors as a function of CNC morphology. Lastly, it is shown that the morphology of CNC can be used as a means to improve sensitivity of IPMC sensors by 3–4 folds.

36 MATERIALS SCIENCE↗

Novel X-ray scanning technique for in-situ alignment of photo-detectors in the MEGII calorimeter

Here, we describe and show results of a novel technique to measure with high precision the positions of photodetectors installed in the upgraded liquid xenon calorimeter of the MEG II experiment. The measurement was done by detecting the signal in individual photo-detectors as the front surface of the calorimeter was scanned in axial (Z) and azimuthal (Φ) directions with a precisely controlled, thin, collimated beam of X-rays obtained from a 57 CoX-ray source. The measurements were made when the calorimeter was cold and operational, under which conditions they could not otherwise be made. This technique is used to check for changes in the photodetector positions due to the effects of cooling and thermal cycling of the support structure and to provide a reference between the positions of the operational photodetectors and alignment markers on the cryostat exterior. The use of an essentially monochromatic X-ray source allowed ancillary measurements of photodetector properties, including pulse shape, relative gain, and variation in response over the photodetector surface. Measurement uncertainties below 0.6mm in Z and 0.7 mrad in Φ have been achieved, well within the requirements for the MEG II performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of diamond-based diagnostics for next-generation XFELs

The composition and performance of three different diamond sensor based pass-through diagnostics are presented. A position-sensitive quadrant sensor was designed and characterized using the XPP beam at the SLAC LCLS, demonstrating a generated-charge resolution of 0.025 pC and a position sensitivity of 2 μm, measurable pulse-by-pulse at a repetition rate of up to 50 MHz. A compact signal path capable of repetition rates up to 1 GHz was used to characterize the charge collection properties of diamond sensors as a function of the density of electron-hole pairs created within the sensor, finding a limit of approximately 10 16 electron-hole pairs per cm 3 beyond which the collection efficiency and time began to degrade. Finally, a proposed scheme for measuring ionizing radiation at multi-GHz rates is presented, along with results preliminarily demonstrating signal transport capability in excess of 5 GHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tungsten erosion during L-mode discharges in the DIII-D SAS-VW divertor

A series of L-mode plasma discharges was performed in the DIII-D tokamak to assess the impact of outer strike point (OSP) position and toroidal magnetic field direction on erosion and core contamination potential of the recently-installed, tungsten-coated Small Angle Slot (SAS-VW) divertor. In one discharge, in-slot emission spectroscopy measured an<48 % increase in the W gross erosion rate when the OSP was moved 3 cm outwards, away from the V-shaped vertex of the slot divertor. However, the effective W yield (erosion rate divided by the incident D flux) was, overall, insensitive to changes in OSP location. Consistently low estimates of the effective W yield based on measurements taken a few cm outwards from the vertex suggest potentially significant C surface contamination. No W emission signal was detected when orienting the toroidal magnetic field such that the ion B×∇B drift direction is pointed away from the X-point. However, measurements of W content in the plasma core for both toroidal magnetic field directions suggest the presence of additional, unmeasured sources of erosion. The difference in the measured core W density with OSP position is much greater than the difference in the measured erosion rates, which may suggest that the leakage of eroded impurities out of the divertor is governed primarily through the parallel ion temperature gradient and friction forces.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Core-collapse supernova explosion simulations

Neutrinos play important roles in the pre-collapse evolution, explosion, and aftermath of core-collapse supernovae. Detected neutrino signals from core-collapse supernovae would provide insight into the explosion mechanism and unknown neutrino mixing parameters. Achieving these goals requires large-scale, multiphysics simulations. For many years, several groups have performed such simulations with increasing realism. Current simulations and plans for future work of the Oak Ridge group are described.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗