Search NASA⌕ Search

SEARCH · Search NASA

Results for “Simulation methods.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

A fourth-order Lagrangian discontinuous Galerkin method using a hierarchical orthogonal basis on curvilinear grids

The existing high-order Lagrangian discontinuous Galerkin (DG) hydrodynamic methods are restricted to using quadratic meshes with quadratic polynomials (P2), which in turn, yield up to third-order accuracy. Additionally, these existing DG hydrodynamic schemes, when extended to work with cubic meshes and cubic polynomials (P3), can be unstable on strong-shock problems. Therefore, this paper presents a new Lagrangian discontinuous Galerkin (DG) hydrodynamic method to simulate compressible material dynamics ( e.g., gasses, fluids, and solids) with strong-shocks using cubic meshes and cubic polynomials, and delivers up to fourth-order accuracy on smooth flows. The stability on shock problems is achieved using new hierarchical orthogonal basis functions and a new subcell mesh stabilization (SMS) scheme for cubic meshes. The accuracy and robustness of the new high-order accurate Lagrangian DG hydrodynamic method is demonstrated by simulating a diverse suite of challenging test problems covering gas and solid dynamic problems on curvilinear meshes.

97 MATHEMATICS AND COMPUTING↗

Local Measurements of Preisach Density in Polycrystalline Ferroelectric Capacitors

Polarization switching in polycrystalline ferroelectric capacitors is explored using piezoresponse force microscopy (PFM) based first-order reversal curve (FORC) measurements. The band excitation method facilitates decoupling the electromechanical responses from variations in surface elastic properties. A simulated annealing method is developed to estimate the Preisach densities from PFM FORC data. Microscopic and macroscopic Preisach densities are compared, illustrating good agreement between the two.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improving small-scale CMB lensing reconstruction

Over the past decade, the gravitational lensing of the Cosmic Microwave Background (CMB) has become a powerful tool for probing the matter distribution in the Universe. The standard technique used to reconstruct the CMB lensing signal employs the quadratic estimator (QE) method, which has recently been shown to be suboptimal for lensing measurements on very small scales in temperature and polarization data. We implement a simple, more optimal method for the small-scale regime, which involves taking the direct inverse of the background gradient. We derive new techniques to make continuous maps of lensing using this "Gradient-Inversion" (GI) method and validate our method with simulated data, finding good agreement with predictions. For idealized simulations of lensing cross- and autospectra that neglect foregrounds, we demonstrate that our method performs significantly better than previous quadratic estimator methods in temperature; at $L=5000-9000$, it reduces errors on the lensing auto-power spectrum by a factor of $\sim 4$ for both idealized CMB-S4 and Simons Observatory-like experiments and by a factor of $\sim 2.6$ for cross-correlations of CMB-S4-like lensing reconstruction and the true lensing field. Finally, we caution that the level of the neglected small-scale foreground power, while low in polarization, is very high in temperature; though we briefly outline foreground mitigation methods, further work on this topic is required. Nevertheless, our results show the future potential for improved small-scale CMB lensing measurements, which could provide stronger constraints on cosmological parameters and astrophysics at high redshifts.

79 ASTRONOMY AND ASTROPHYSICS↗

Automatic CT simulation optimization for radiation therapy: A general strategy

Purpose: In radiation therapy, x-ray computed tomography (CT) simulation protocol specifications should be driven by the treatment planning requirements in lieu of duplicating diagnostic CT screening protocols. The purpose of this study was to develop a general strategy that allows for automatically, prospectively, and objectively determining the optimal patient-specific CT simulation protocols based on radiation-therapy goals, namely, maintenance of contouring quality and integrity while minimizing patient CT simulation dose. Methods: The authors proposed a general prediction strategy that provides automatic optimal CT simulation protocol selection as a function of patient size and treatment planning task. The optimal protocol is the one that delivers the minimum dose required to provide a CT simulation scan that yields accurate contours. Accurate treatment plans depend on accurate contours in order to conform the dose to actual tumor and normal organ positions. An image quality index, defined to characterize how simulation scan quality affects contour delineation, was developed and used to benchmark the contouring accuracy and treatment plan quality within the predication strategy. A clinical workflow was developed to select the optimal CT simulation protocols incorporating patient size, target delineation, and radiation dose efficiency. An experimental study using an anthropomorphic pelvis phantom with added-bolus layers was used to demonstrate how the proposed prediction strategy could be implemented and how the optimal CT simulation protocols could be selected for prostate cancer patients based on patient size and treatment planning task. Clinical IMRT prostate treatment plans for seven CT scans with varied image quality indices were separately optimized and compared to verify the trace of target and organ dosimetry coverage. Results: Based on the phantom study, the optimal image quality index for accurate manual prostate contouring was 4.4. The optimal tube potentials for patient sizes of 38, 43, 48, 53, and 58 cm were 120, 140, 140, 140, and 140 kVp, respectively, and the corresponding minimum CTDIvol for achieving the optimal image quality index 4.4 were 9.8, 32.2, 100.9, 241.4, and 274.1 mGy, respectively. For patients with lateral sizes of 43–58 cm, 120-kVp scan protocols yielded up to 165% greater radiation dose relative to 140-kVp protocols, and 140-kVp protocols always yielded a greater image quality index compared to the same dose-level 120-kVp protocols. The trace of target and organ dosimetry coverage and the γ passing rates of seven IMRT dose distribution pairs indicated the feasibility of the proposed image quality index for the predication strategy. Conclusions: A general strategy to predict the optimal CT simulation protocols in a flexible and quantitative way was developed that takes into account patient size, treatment planning task, and radiation dose. The experimental study indicated that the optimal CT simulation protocol and the corresponding radiation dose varied significantly for different patient sizes, contouring accuracy, and radiation treatment planning tasks.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predicting the mineral composition of dust aerosols – Part 2: Model evaluation and identification of key processes with observations

A global compilation of nearly sixty measurement studies is used to evaluate two methods of simulating the mineral composition of dust aerosols in an Earth system model. Both methods are based upon a Mean Mineralogical Table (MMT) that relates the soil mineral fractions to a global atlas of arid soil type. The Soil Mineral Fraction (SMF) method assumes that the aerosol mineral fractions match the fractions of the soil. The MMT is based upon soil measurements after wet sieving, a process that destroys aggregates of soil particles that would have been emitted from the original, undisturbed soil. The second method approximately reconstructs the emitted aggregates. This model is referred to as the Aerosol Mineral Fraction (AMF) method because the mineral fractions of the aerosols differ from those of the wet-sieved parent soil, partly due to reaggregation. The AMF method remedies some of the deficiencies of the SMF method in comparison to observations. Only the AMF method exhibits phyllosilicate mass at silt sizes, where they are abundant according to observations. In addition, the AMF quartz fraction of silt particles is in better agreement with measured values, in contrast to the overestimated SMF fraction. Measurements at distinct clay and silt particle sizes are shown to be more useful for evaluation of the models, in contrast to the sum over all particles sizes that is susceptible to compensating errors, as illustrated by the SMF experiment. Model errors suggest that allocation of the emitted silt fraction of each mineral into the corresponding transported size categories is an important remaining source of uncertainty. Evaluation of both models and the MMT is hindered by the limited number of size-resolved measurements of mineral content that sparsely sample aerosols from the major dust sources. In conclusion, the importance of climate processes dependent upon aerosol mineral composition shows the need for global and routine mineral measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploring new frontiers in statistical physics with a new, parallel Wang-Landau framework

Combining traditional Wang Landau sampling for multiple replica systems with an exchange of densities of states between replicas we describe a general framework for simulations on massively parallel Petaflop supercomputers. The advantages and general applicability of the method for simulations of complex systems are demonstrated for the classical 2D Potts spin model featuring a strong first-order transition and the self-assembly of lipid bilayers in amphiphilic solutions in a continuous model.

Vogel, Thomas↗

Assessment of Updraft Modeling Bias Using Computational Fluid Dynamics

Golden Eagle (Aquila chrysaetos) habitats may overlap with wind energy development in some regions of the US. Eagles, and similar soaring bird species, are therefore at risk of collision with wind turbines when flying through wind farms. Recently developed behavioral modeling approaches can predict the presence of eagles near turbines within the rotor-swept layer but require reliable prediction of atmospheric flowfield conditions. In particular, the vertical component of the wind speed dictates a soaring bird's ability to maintain or gain altitude, since they rely on updrafts to subsidize their flight. In this work, we investigate the atmospheric conditions around a wind farm in complex terrain and compare methods for atmospheric characterization. We use computational fluid dynamics (specifically, large-eddy simulations, or LES) to simulate the atmospheric boundary layer over a region encompassing multiple wind farms with high temporal and spatial resolution (seconds and 10's of meters, respectively). We compare traditional non-simulation-based methods of determining the orographic updraft potential based on wind direction, terrain slope and aspect, with the flowfields from LES that include both orographic updrafts alone and combined thermal and orographic updrafts. Preliminary analysis suggests that although the model captures the horizontal pattern of vertical updrafts, their magnitude can be improved with information about the surface heat flux, which is usually correlated with time of the day. Within our study region, we found that the low-fidelity model may over- or underestimate updraft potential by up to 400% at 80 m AGL, depending on local orographic features. This can result in an inaccurate representation of eagle presence and, consequently, risk. Another important finding is that flowfield time-averaging can hide important details about the flight environment, including how thermally generated flow structures within the atmospheric boundary layer (e.g., convective rolls and/or cells) may be important drivers of eagle flight.

atmospheric turbulence↗

Verification and validation of residual stresses in composite structures

Process-induced residual stresses occur in composite structures composed of dissimilar materials. As these residual stresses could result in fracture, their consideration when designing composite parts is necessary. However, the experimental determination of residual stresses in prototype parts can be time and cost prohibitive. Alternatively, it is possible for computational tools to predict potential residual stresses. Therefore, the objectives of the presented work are to demonstrate an efficient method for simulating residual stresses in composite parts, as well as the potential value of statistical methods during analyses for which material properties are unknown. Specifically, a simplified residual stress modeling approach is implemented within Sandia National Laboratories’ SIERRA/SolidMechanics code. Concurrent with the model development, bi-material composite structures are designed and manufactured to exhibit significant residual stresses. Then, the presented modeling approach is rigorously verified and validated through simulations of the bi-material composite structures’ manufacturing processes, including a mesh convergence study, sensitivity analysis, and uncertainty quantification. The simulations’ final results show adequate agreement with the experimental measurements, indicating the validity of a simple modeling approach, as well as a necessity for the inclusion of material parameter uncertainty in the final residual stress predictions.

42 ENGINEERING↗

Impact of plasma response on plasma displacements in DIII-D during application of external 3D perturbations

The effects of applied non-axisymmetric resonant magnetic perturbations (RMPs) are predicted without and with self-consistent plasma response by modeling of the magnetic field structure and two-fluid MHD simulations, respectively. A synthetic diagnostic is used to simulate soft X-ray (SXR) emission within the steep gradient region of the pedestal, 0.98 > ψ > 0.94. The entire pedestal and edge region is characterized by large changes in plasma rotation and current density. Those parameters are expected to strongly affect the plasma response to RMPs. The M3D-C1 code takes into account this response self-consistently. The plasma response is investigated in detail and used in the forward modeling of the simulated local SXR emission, within the framework of the synthetic diagnostic. The resulting synthetic emission is compared to measured SXR data. The latter clearly shows helical m = 11 ± 1 displacements around the 11/3 rational surface of sizes up to 5 cm, which change with the poloidal angle. The synthetic emission with plasma response is used to explain the nature of the measured displacements. Different approaches are tested. One approach is based on the magnetic field structure to simulate local emission, which shows additional structures at the separatrix, that are caused by the lobes. Especially without plasma response, almost only separatrix structures are generated while no significant displacements are found further inside. Another approach to model local emission uses the fluid quantities electron density and temperature, as calculated by M3D-C1. Compared to the previous approach, based on the magnetic field structure, the emission simulated by the fluid approach with plasma response shows better agreement with the measured SXR data. To be specific, it has comparable displacements in the steep gradient region and no lobe structures at all. The helical displacements around the 11/3 surface are identified to be directly related to the kink response, caused by non-resonant amplification of various poloidal RMP modes due to plasma response. Regarding the latter, the role of different plasma parameters is investigated, but it appears that the electron rotation plays a key role in the formation of screening and resonant amplification, while the kinking appears to be sensitive to the edge current density. As a result, it is also hypothesised that the strength of the kink response is also correlated to edge-localized-mode (ELM) stability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Extending continuum models for atom probe simulation

Highlights: • Demonstration of 3D curvature level set methods for APT simulations • Demonstration of non-rotationally symmetric tip shape simulations • Optimised speed for simulations, calculations achievable on minute timescales This work describes extensions to existing level-set algorithms developed for application within the field of atom probe tomography (APT). We present a new simulation tool for the simulation of 3D tomographic volumes, using advanced level set methods. By combining narrow-band, B-Tree and particle-tracing approaches from level-set methods, we demonstrate a practical tool for simulating shape changes to APT samples under applied electrostatic fields, in three dimensions. This work builds upon our previous studies by allowing for non-axially symmetric solutions, with minimal loss in computational speed, whilst retaining numerical accuracy.

36 MATERIALS SCIENCE↗

Auto calibration of a cone-beam-CT

Purpose: This paper introduces a novel autocalibration method for cone-beam-CTs (CBCT) or flat-panel CTs, assuming a perfect rotation. The method is based on ellipse-fitting. Autocalibration refers to accurate recovery of the geometric alignment of a CBCT device from projection images alone, without any manual measurements. Methods: The authors use test objects containing small arbitrarily positioned radio-opaque markers. No information regarding the relative positions of the markers is used. In practice, the authors use three to eight metal ball bearings (diameter of 1 mm), e.g., positioned roughly in a vertical line such that their projection image curves on the detector preferably form large ellipses over the circular orbit. From this ellipse-to-curve mapping and also from its inversion the authors derive an explicit formula. Nonlinear optimization based on this mapping enables them to determine the six relevant parameters of the system up to the device rotation angle, which is sufficient to define the geometry of a CBCT-machine assuming a perfect rotational movement. These parameters also include out-of-plane rotations. The authors evaluate their method by simulation based on data used in two similar approaches [L. Smekal, M. Kachelriess, S. E, and K. Wa, 'Geometric misalignment and calibration in cone-beam tomography,' Med. Phys. 31(12), 3242-3266 (2004); K. Yang, A. L. C. Kwan, D. F. Miller, and J. M. Boone, 'A geometric calibration method for cone beam CT systems,' Med. Phys. 33(6), 1695-1706 (2006)]. This allows a direct comparison of accuracy. Furthermore, the authors present real-world 3D reconstructions of a dry human spine segment and an electronic device. The reconstructions were computed from projections taken with a commercial dental CBCT device having two different focus-to-detector distances that were both calibrated with their method. The authors compare their reconstruction with a reconstruction computed by the manufacturer of the CBCT device to demonstrate the achievable spatial resolution of their calibration procedure. Results: Compared to the results published in the most closely related work [K. Yang, A. L. C. Kwan, D. F. Miller, and J. M. Boone, 'A geometric calibration method for cone beam CT systems,' Med. Phys. 33(6), 1695-1706 (2006)], the simulation proved the greater accuracy of their method, as well as a lower standard deviation of roughly 1 order of magnitude. When compared to another similar approach [L. Smekal, M. Kachelriess, S. E, and K. Wa, 'Geometric misalignment and calibration in cone-beam tomography,' Med. Phys. 31(12), 3242-3266 (2004)], their results were roughly of the same order of accuracy. Their analysis revealed that the method is capable of sufficiently calibrating out-of-plane angles in cases of larger cone angles when neglecting these angles negatively affects the reconstruction. Fine details in the 3D reconstruction of the spine segment and an electronic device indicate a high geometric calibration accuracy and the capability to produce state-of-the-art reconstructions. Conclusions: The method introduced here makes no requirements on the accuracy of the test object. In contrast to many previous autocalibration methods their approach also includes out-of-plane rotations of the detector. Although assuming a perfect rotation, the method seems to be sufficiently accurate for a commercial CBCT scanner. For devices which require higher dimensional geometry models, the method could be used as a initial calibration procedure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microstructure-process relationships in monolithic U-10Mo fuel foil single-pass rolling: A parametric simulation study

In this work, a previously validated coupling of Kinetic Monte Carlo (KMC) Potts Model and finite element method (FEM) simulations was implemented to investigate the effects of microstructural features in as-cast and homogenized monolithic U-10Mo foils on the emergent microstructure after rolling and reheating. Parameters that could potentially affect recrystallization behavior of the rolled U-10Mo foils were considered: grain size distribution, uranium carbide (UC) size distribution, UC volume fraction, spatial distribution of UC, and rolling reduction magnitude. Grain structure and the magnitude of rolling reduction have the strongest influence on recrystallization kinetics and the fabricated grain size distribution. The UC distribution had only a weak effect on the recrystallization kinetics and final microstructures. While particle-stimulated nucleation (PSN) occurred in simulation more frequently as grain size increased, its incidence did not appear to considerably affect the recrystallization kinetics or grain size distribution.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Simulating Marine Stratocumulus Clouds using Lagrangian Superdroplet Method in ERF

This study investigates the simulation of marine stratocumulus (stratoCu) clouds – common in many offshore and coastal wind energy regions - using Lagrangian Superdroplet Method (SDM) implemented in Energy Research and Forecasting (ERF) model. Developed by the Wind Energy Technologies Office (WETO), ERF is a high-resolution atmospheric modeling tool that relies on traditional bulk microphysics schemes. Under an LLNL-led Laboratory Directed Research and Development (LDRD) project, SDM was integrated into ERF to improve cloud process fidelity by explicitly tracking individual “superdroplets”. This enables a realistic representation of the droplet size spectrum, cloud-atmosphere interactions, and potential feedbacks from wind plants on atmospheric flow and cloud structure.

54 ENVIRONMENTAL SCIENCES↗

Monte Carlo simulation of nanoscale material focused ion beam gas-assisted etching: Ga + and Ne + etching of SiO 2 in the presence of a XeF 2 precursor gas

Elucidating energetic particle-precursor gas–solid interactions is critical to many atomic and nanoscale synthesis approaches. Focused ion beam sputtering and gas-assisted etching are among the more commonly used direct-write nanomachining techniques that have been developed. Here, we demonstrate a method to simulate gas-assisted focused ion beam (FIB) induced etching for editing/machining materials at the nanoscale. The method consists of an ion–solid Monte Carlo simulation, to which we have added additional routines to emulate detailed gas precursor–solid interactions, including the gas flux, adsorption, and desorption. Furthermore, for the reactive etching component, a model is presented by which energetic ions/target atoms, and secondary electrons, transfer energy to adsorbed gas molecules. The simulation is described in detail, and is validated using analytical and experimental data for surface gas adsorption, and etching yields. The method is used to study XeF 2 assisted FIB induced etching of nanoscale vias, using both a 35 keV Ga + , and a 10 keV Ne + beam. Remarkable agreement between experimental and simulated nanoscale vias is demonstrated over a range of experimental conditions. Importantly, we demonstrate that the resolution depends strongly on the XeF 2 gas flux, with optimal resolution obtained for either pure sputtering, or saturated gas coverage; saturated gas coverage has the clear advantage of lower overall dose, and thus lower implant damage, and much faster processing.

36 MATERIALS SCIENCE↗

Impacts of stochastic coalescence variability on warm rain initiation using Lagrangian microphysics in box and large-eddy simulations

Various coalescence methods for Lagrangian microphysics schemes are tested in box and large-eddy simulation (LES) models, including the stochastic all-or-nothing super-droplet method (SDM) and a version of SDM (dSDM) that applies a fractional approach similar to the average impact method. In LES, variabilities driven by microphysics and by flow realizations are separated using the “piggybacking” technique. Rain initiation averaged over many realizations of the box model is delayed and rain variability increases as the number of super-drops per collision volume ( N SD ) is decreased using SDM. In contrast, rain initiation time using SDM in LES is insensitive to N SD for 32 ≤ N SD ≤ 512. This is explained through the interaction between LES grid boxes, each acting as a separate collision volume. Variability across the ensemble of LES collision volumes using SDM results in rain quickly initiating in some of the LES grid cells at low N SD and leading to a similar overall timing of rain initiation from the cloud compared to simulations with high N SD . There is a ~20% decrease in the total rain mass and mean rain flux as N SD is increased from 32 to 256, with little additional change as N SD is increased from 256 to 512. The fractional coalescence approach in dSDM leads to reduced microphysical variability and a 15-18 min delay in rain initiation compared to SDM. Finally, an additional LES ensemble with microphysical variability feeding back to the dynamics shows that flow variability dominates the impact of microphysical variability on rain properties. Thus, flow variability must be constrained to isolate impacts of microphysical variability.

54 ENVIRONMENTAL SCIENCES↗

Disentangling the confounding spectroscopy of C 1 molecules: Without symmetry as a guide, everything is allowed

The spectra of C 1 molecules are confounding in that each of the fundamental vibrational modes transform as the same irreducible representation (A) and hence each band consists of a seemingly random distribution of a-, b-, and c-type transitions. This is in contrast to higher symmetry molecules for which band types are readily deduced by simple symmetry rules. Herein, we present a method to simulate the convoluted rotational contours in the gas-phase spectra of C 1 molecules by combining existing ab initio calculations with Colin Western’s PGOPHER rotational contour program. Specifically, ab initio calculations in the NWC HEM suite of programs were employed to predict the components of the dipole moment derivatives along the principal axes of the moments of inertia. This information was then input into PGOPHER to model the fundamental band contours as a sum of a-, b-, and c-type transitions. This method was applied to simulate the rotational contour spectra of a series of representative C 1 molecules which were then compared against both ab initio stick spectra and experimentally measured broadband IR spectra from the Pacific Northwest National Laboratory infrared gas-phase database. In addition to providing further insight beyond what is revealed in a typical stick spectrum, the simulated contours showed good agreement with the measured spectra.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Moving target irradiation with fast rescanning and gating in particle therapy

Purpose: In moving target irradiation with pencil beam scanning, the interplay effect between the target motion and the scanned beam is a problem because this effect causes over or under dosage in the target volume. To overcome this, we have studied rescanning using a gating technique. Methods: A simulation and experimental study was carried out. In the experiment, we used the fast scanning system developed at the HIMAC to verify the validity of phase controlled rescanning method, in which the time for rescanning irradiation of each slice is matched to the gating duration. Results: Simulation and experimental results showed that controlling the scan speed to match the respiration cycle with rescans can deliver the blurred dose distribution. In the comparison between the static measurements and the moving measurements with the phase controlled rescanning method, the dose difference was less than 2% for pinpoint chambers in the target volume. Conclusions: The simulation and experimental results demonstrated that the phase controlled rescanning method makes it possible to deliver the dose distribution close to the expected one. As an experimental result for 3D irradiation, it was estimated that blurring by the probability density function was not only for a lateral distribution, but also for a distal distribution, even in the lateral rescanning.

61 RADIATION PROTECTION AND DOSIMETRY↗

Parallel continuous simulated tempering and its applications in large-scale molecular simulations

In this paper, we introduce a parallel continuous simulated tempering (PCST) method for enhanced sampling in studying large complex systems. It mainly inherits the continuous simulated tempering (CST) method in our previous studies [C. Zhang and J. Ma, J. Chem. Phys. 130, 194112 (2009); C. Zhang and J. Ma, J. Chem. Phys. 132, 244101 (2010)], while adopts the spirit of parallel tempering (PT), or replica exchange method, by employing multiple copies with different temperature distributions. Differing from conventional PT methods, despite the large stride of total temperature range, the PCST method requires very few copies of simulations, typically 2–3 copies, yet it is still capable of maintaining a high rate of exchange between neighboring copies. Furthermore, in PCST method, the size of the system does not dramatically affect the number of copy needed because the exchange rate is independent of total potential energy, thus providing an enormous advantage over conventional PT methods in studying very large systems. The sampling efficiency of PCST was tested in two-dimensional Ising model, Lennard-Jones liquid and all-atom folding simulation of a small globular protein trp-cage in explicit solvent. The results demonstrate that the PCST method significantly improves sampling efficiency compared with other methods and it is particularly effective in simulating systems with long relaxation time or correlation time. We expect the PCST method to be a good alternative to parallel tempering methods in simulating large systems such as phase transition and dynamics of macromolecules in explicit solvent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗