Search NASA⌕ Search

SEARCH · Search NASA

Results for “interval analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

An overview of IACG campaign 4: Solar sources of heliospheric structure observed out of the ecliptic

In 1994, the Inter Agency Consultative Group (IACG), with represenation from ESA, the Japanese Institute of Space and Astronautical Science, the Russian Space Agency, and NASA, initiated a data analysis campaign entitled: 'solar sources of heliospheric structure observed out of the ecliptic' (IACG campaign 4). The primary campaign themes are: the large-scale heliosphere and its dependence on solar photospheric and coronal phenomena; the topology of coronal streamers; the 3D shape of coronal hole boundaries, and solar wind source and acceleration. These themes emphasize the collaborative analysis of remote sensing and in situ data sets for solar features such as coronal holes, coronal mass ejections, and other other solar sources of heliospheric structure. The key observation intervals, covering June 1994 to January 1997, were selected based on the timeline of the unique trajectory of the Ulysses mission. The capabilities and opportunities afforded by the core campaing missions, Ulysses and Yohkoh, and the availability of supportin solar ground observatories and other spacecraft missions, make this campaign of special interest to the solar and heliospheric communities.

Galvin, A. B.↗

Impact of lossy compression on diagnostic accuracy of radiographs for periapical lesions

OBJECTIVES: The purpose of this study was to evaluate the lossy Joint Photographic Experts Group compression for endodontic pretreatment digital radiographs. STUDY DESIGN: Fifty clinical charge-coupled device-based, digital radiographs depicting periapical areas were selected. Each image was compressed at 2, 4, 8, 16, 32, 48, and 64 compression ratios. One root per image was marked for examination. Images were randomized and viewed by four clinical observers under standardized viewing conditions. Each observer read the image set three times, with at least two weeks between each reading. Three pre-selected sites per image (mesial, distal, apical) were scored on a five-scale score confidence scale. A panel of three examiners scored the uncompressed images, with a consensus score for each site. The consensus score was used as the baseline for assessing the impact of lossy compression on the diagnostic values of images. The mean absolute error between consensus and observer scores was computed for each observer, site, and reading session. RESULTS: Balanced one-way analysis of variance for all observers indicated that for compression ratios 48 and 64, there was significant difference between mean absolute error of uncompressed and compressed images (P <.05). After converting the five-scale score to two-level diagnostic values, the diagnostic accuracy was strongly correlated (R (2) = 0.91) with the compression ratio. CONCLUSION: The results of this study suggest that high compression ratios can have a severe impact on the diagnostic quality of the digital radiographs for detection of periapical lesions.

NASA Discipline Space Human Factors↗

Path Loss Prediction Over the Lunar Surface Utilizing a Modified Longley-Rice Irregular Terrain Model

This study introduces the use of a modified Longley-Rice irregular terrain model and digital elevation data representative of an analogue lunar site for the prediction of RF path loss over the lunar surface. The results are validated by theoretical models and past Apollo studies. The model is used to approximate the path loss deviation from theoretical attenuation over a reflecting sphere. Analysis of the simulation results provides statistics on the fade depths for frequencies of interest, and correspondingly a method for determining the maximum range of communications for various coverage confidence intervals. Communication system engineers and mission planners are provided a link margin and path loss policy for communication frequencies of interest.

Foore, Larry↗

Direct Measurement of the Cosmic-Ray Helium Spectrum from 40 GeV to 250 TeV with the Calorimetric Electron Telescope on the International Space Station

We present the results of a direct measurement of the cosmic-ray helium spectrum with the CALET instrument in operation on the International Space Station since 2015. The observation period covered by this analysis spans from October 13, 2015, to April 30, 2022 (2392 days). The very wide dynamic range of CALET allowed for the collection of helium data over a large energy interval, from ∼40 GeV to ∼250 TeV, for the first time with a single instrument in low Earth orbit. The measured spectrum shows evidence of a deviation of the flux from a single power law by more than 8σ with a progressive spectral hardening from a few hundred GeV to a few tens of TeV. This result is consistent with the data reported by space instruments including PAMELA, AMS-02, and DAMPE and balloon instruments including CREAM. At higher energy we report the onset of a softening of the helium spectrum around 30 TeV (total kinetic energy). Though affected by large uncertainties in the highest energy bins, the observation of a flux reduction turns out to be consistent with the most recent results of DAMPE. A double broken power law is found to fit simultaneously both spectral features: the hardening (at lower energy) and the softening (at higher energy). A measurement of the proton to helium flux ratio in the energy range from 60 GeV=n to about 60 TeV=n is also presented, using the CALET proton flux recently updated with higher statistics.

O Adriani↗

Thermo-Mechanical Analysis of Coated Particle Fuel Experiencing a Fast Control Rod Ejection Transient

A rapid increase of the temperature and the mechanical stress is expected in TRISO coated particle fuel that experiences a fast Total Control Rod Ejection (CRE) transient event. During this event the reactor power in the pebble bed core increases significantly for a short time interval. The power is deposited instantly and locally in the fuel kernel. This could result in a rapid increase of the pressure in the buffer layer of the coated fuel particle and, consequently, in an increase of the coating stresses. These stresses determine the mechanical failure probability of the coatings, which serve as the containment of radioactive fission products in the Pebble Bed Reactor (PBR). A new calculation procedure has been implemented at the Idaho National Laboratory (INL), which analyzes the transient fuel performance behavior of TRISO fuel particles in PBRs. This early capability can easily be extended to prismatic designs, given the availability of neutronic and thermal-fluid solvers. The full-core coupled neutronic and thermal-fluid analysis has been modeled with CYNOD-THERMIX. The temperature fields for the fuel kernel and the particle coatings, as well as the gas pressures in the buffer layer, are calculated with the THETRIS module explicitly during the transient calculation. Results from this module are part of the feedback loop within the neutronic-thermal fluid iterations performed for each time step. The temperature and internal pressure values for each pebble type in each region of the core are then input to the PArticle STress Analysis (PASTA) code, which determines the particle coating stresses and the fraction of failed particles. This paper presents an investigation of a Total Control Rod Ejection (TCRE) incident in the 400 MWth Pebble Bed Modular reactor design using the above described calculation procedure. The transient corresponds to a reactivity insertion of $3 (~2000 pcm) reaching 35 times the nominal power in 0.5 seconds. For each position in the core the coated particle temperature and the stress history during a TCRE transient has been computed and the fuel failure probability has been quantified.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A stochastic model of future extreme temperature events for infrastructure analysis

Applying extreme temperature events for future conditions is not straightforward for infrastructure resilience analyses. This work introduces a stochastic model that fills this gap. The model uses at least 50 years of daily extreme temperature records, climate normals with 10%-90% confidence intervals, and shifts/offsets for increased frequency and intensity of heat wave events. Intensity and frequency are shifted based on surface temperature anomaly from 1850-1900 for 32 models from CMIP6. A case study for Worcester, Massachusetts passed 85% of cases using the two-sided Kolmogorov-Smirnov -value test with 95% confidence for both temperature and duration. Future shifts for several climate scenarios to 2020, 2040, 2060, and 2080 had acceptable errors between the shifted model and 10- and 50-year extreme temperature event thresholds with the largest error being 2.67 degrees C. The model is likely to be flexible enough for other patterns of extreme weather such as extreme precipitation and hurricanes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Impact of Glass Irradiation on Laser-Induced Breakdown Spectroscopy Data Analysis

Increased absorption of optical materials arising from exposure to ionizing radiation must be accounted for to accurately analyze laser-induced breakdown spectroscopy (LIBS) data retrieved from high-radiation environments. We evaluate this effect on two examples that mimic the diagnostics placed within novel nuclear reactor designs. The analysis is performed on LIBS data measured with 1% Xe gas in an ambient He environment and 1% Eu in a molten LiCl-KCl matrix, along with the measured optical absorption from the gamma- and neutron-irradiated low-OH fused silica and sapphire glasses. Significant changes in the number of laser shots required to reach a 3σ detection level are observed for the Eu data, increasing by two orders of magnitude after exposure to a 1.7 × 1017 n/cm2 neutron fluence. For all cases examined, the spectral dependence of absorption results in the introduction of systematic errors. Moreover, if lines from different spectral regions are used to create Boltzmann plots, this attenuation leads to statistically significant changes in the temperatures calculated from the Xe II lines and Eu II lines, lowering them from 8000 ± 610 K to 6900 ± 810 K and from 15,800 ± 400 K to 7200 ± 800 K, respectively, for exposure to the 1.7 × 1017 n/cm2 fluence. The temperature range required for a 95% confidence interval for the calculated temperature is also broadened. In the case of measuring the Xe spectrum, these effects may be mitigated using only the longer-wavelength spectral region, where radiation attenuation is relatively small, or through analysis using the iterative Saha–Boltzmann method.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Can the Analysis of ERCC1 Expression Contribute to Individualized Therapy in Nasopharyngeal Carcinoma?

Purpose: To analyze the expression of excision repair cross-complementation group 1 (ERCC1) protein in predicting the clinical outcome of nasopharyngeal carcinoma (NPC). Methods and Materials: The histologic specimens of 258 patients with Stage III to IVB nonkeratinizing NPC who were treated with radiotherapy alone (Group I) or concurrent-adjuvant chemoradiotherapy (Group II) were retrieved. Immunostaining on ERCC1 protein was performed. The relationship of ERCC1 expression and clinical outcomes was analyzed. Results: The median ERCC1 score (proportion score of positively stained cells times intensity) was 200 (range, 0-300), and ERCC1 expression was defined as high if the score was above the median. In Group I high-score tumor had a statistically lower locoregional failure-free rate (LRFFR) compared with low-score tumor (p < 0.05) but not distant failure-free rate (DFFR) and overall survival (OS). In Group II no statistically differences were noted in LRFFR, DFFR and OS with regard to the ERCC1 expression. Resistance to cisplatin-containing chemotherapy in high-ERCC1 score tumor was not observed in Group II. Interestingly, low-score tumor in Group I achieved similar local and distant control compared with Group II. Multivariate analysis showed that ERCC1 score was an independent prognostic factor in LRFFR (p < 0.05) and approached statistical significance in failure-free survival (p = 0.08) and OS (p = 0.07). Tumor with high ERCC1 score had a 2-fold (95% confidence interval, 1.02-3.85) increased risk of locoregional failure. This may imply an association of ERCC1 expression with the repair of radiation damage. Conclusions: High ERCC1 expression predicts poor locoregional control in NPC. Chemotherapy response is not affected by ERCC1 expression. Further validation is required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Planetary Ephemeris Program: Capability, Comparison, and Open Source Availability

We describe for the first time in scientific literature the Planetary Ephemeris Program (PEP), an open-source general-purpose astrometric data-analysis program. We discuss, in particular, the implementation of pulsar timing analysis, which was recently upgraded in PEP to handle more options. This implementation was done independently of other pulsar programs, with minor exceptions that we discuss. We illustrate the implementation of this capability by comparing the postfit residuals from the analyses of time-of-arrival observations by both PEP and Tempo2. The comparison shows substantial agreement: 22 ns rms differences for 1065 pulse time-of-arrival measurements for the millisecond pulsar in a binary system, PSR J1909-3744 (pulse period 2.947108 ms; full width half maximum of pulse 43 μs), for epochs in the interval from 2002 December to 2011 February.

42 ENGINEERING↗

STUDIES IN ASTRONOMICAL TIME SERIES ANALYSIS. VI. BAYESIAN BLOCK REPRESENTATIONS

This paper addresses the problem of detecting and characterizing local variability in time series and other forms of sequential data. The goal is to identify and characterize statistically significant variations, at the same time suppressing the inevitable corrupting observational errors. We present a simple nonparametric modeling technique and an algorithm implementing it-an improved and generalized version of Bayesian Blocks-that finds the optimal segmentation of the data in the observation interval. The structure of the algorithm allows it to be used in either a real-time trigger mode, or a retrospective mode. Maximum likelihood or marginal posterior functions to measure model fitness are presented for events, binned counts, and measurements at arbitrary times with known error distributions. Problems addressed include those connected with data gaps, variable exposure, extension to piecewise linear and piecewise exponential representations, multivariate time series data, analysis of variance, data on the circle, other data modes, and dispersed data. Simulations provide evidence that the detection efficiency for weak signals is close to a theoretical asymptotic limit derived by Arias-Castro et al. In the spirit of Reproducible Research all of the code and data necessary to reproduce all of the figures in this paper are included as supplementary material.

79 ASTRONOMY AND ASTROPHYSICS↗

Core-halo age gradients and star formation in the Orion Nebula and NGS 2024 young stellar clusters

We analyze age distributions of two nearby rich stellar clusters, the NGC 2024 (Flame Nebula) and Orion Nebula cluster (ONC) in the Orion molecular cloud complex. Our analysis is based on samples from the MYStIX survey and a new estimator of pre-main sequence (PMS) stellar ages, Age{sub JX} , derived from X-ray and near-infrared photometric data. To overcome the problem of uncertain individual ages and large spreads of age distributions for entire clusters, we compute median ages and their confidence intervals of stellar samples within annular subregions of the clusters. We find core-halo age gradients in both the NGC 2024 cluster and ONC: PMS stars in cluster cores appear younger and thus were formed later than PMS stars in cluster peripheries. These findings are further supported by the spatial gradients in the disk fraction and K-band excess frequency. Our age analysis is based on Age{sub JX} estimates for PMS stars and is independent of any consideration of OB stars. The result has important implications for the formation of young stellar clusters. One basic implication is that clusters form slowly and the apparent age spreads in young stellar clusters, which are often controversial, are (at least in part) real. The result further implies that simple models where clusters form inside-out are incorrect and more complex models are needed. We provide several star formation scenarios that alone or in combination may lead to the observed core-halo age gradients.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of the Effectiveness of Radiofrequency Ablation With Stereotactic Body Radiation Therapy in Inoperable Stage I Non-Small Cell Lung Cancer: A Systemic Review and Pooled Analysis

Purpose: To performed a systematic review and pooled analysis to compare clinical outcomes of stereotactic body radiation therapy (SBRT) and radiofrequency ablation (RFA) for the treatment of medically inoperable stage I non-small cell lung cancer. Methods and Materials: A comprehensive literature search for published trials from 2001 to 2012 was undertaken. Pooled analyses were performed to obtain overall survival (OS) and local tumor control rates (LCRs) and adverse events. Regression analysis was conducted considering each study's proportions of stage IA and age. Results: Thirty-one studies on SBRT (2767 patients) and 13 studies on RFA (328 patients) were eligible. The LCR (95% confidence interval) at 1, 2, 3, and 5 years for RFA was 77% (70%-85%), 48% (37%-58%), 55% (47%-62%), and 42% (30%-54%) respectively, which was significantly lower than that for SBRT: 97% (96%-98%), 92% (91%-94%), 88% (86%-90%), and 86% (85%-88%) (P<.001). These differences remained significant after correcting for stage IA and age (P<.001 at 1 year, 2 years, and 3 years; P=.04 at 5 years). The effect of RFA was not different from that of SBRT on OS (P>.05). The most frequent complication of RFA was pneumothorax, occurring in 31% of patients, whereas that for SBRT (grade ≥3) was radiation pneumonitis, occurring in 2% of patients. Conclusions: Compared with RFA, SBRT seems to have a higher LCR but similar OS. More studies with larger sample sizes are warranted to validate such findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Data Analysis for Explosive Firesets [Poster]

I analyzed the data from various detonators at different initial voltages to find the RLC values (resistance, inductance, capacitance) of the fireset. The data I was given contained a current and voltage for each time value taken on nanosecond intervals. From this, I was able to make plots of several variables to try and find which if any of variables correlated with a burst or a go. These results will allow us to fully understand what is required to achieve a burst in the bridgewire so that we can know what is safe or what will never cause detonation. We may also be able to predict the outcome of using the same fireset with different detonators or with different sizes or materials of bridgewire.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Lung Cancer in the Mayak Workers Cohort: Risk Estimation and Uncertainty Analysis

The workers at the Mayak nuclear facility near Ozyorsk, Russia are a primary source of information about exposure to radiation at low-dose rates, since they were subject to protracted exposures to external gamma rays and to internal exposures from plutonium inhalation. Here we re-examine lung cancer mortality rates and assess the effects of external gamma and internal plutonium exposures using recently developed Monte Carlo dosimetry systems. Using individual lagged mean annual lung doses computed from the dose realizations, we fit excess relative risk (ERR) models to the lung cancer mortality data for the Mayak Workers Cohort using risk-modeling software. We then used the corrected information matrix (CIM) approach to widen the confidence intervals of ERR by taking into account the uncertainty in doses represented by multiple realizations from the Monte Carlo dosimetry systems. Findings of this work revealed that there were 930 lung cancer deaths during follow-up. Plutonium lung doses (but not gamma doses) were generally higher in the new dosimetry systems than those used in the previous analysis. This led to a reduction in the risk per unit dose compared to prior estimates. The estimated ERR/Gy for external gamma-ray exposure was 0.19 (95% CI: 0.07 to 0.31) for both sexes combined, while the ERR/Gy for internal exposures based on mean plutonium doses were 3.5 (95% CI: 2.3 to 4.6) and 8.9 (95% CI: 3.4 to 14) for males and females at attained age 60. Accounting for uncertainty in dose had little effect on the confidence intervals for the ERR associated with gamma-ray exposure, but had a marked impact on confidence intervals, particularly the upper bounds, for the effect of plutonium exposure [adjusted 95% CIs: 1.5 to 8.9 for males and 2.7 to 28 for females]. In conclusion, lung cancer rates increased significantly with both external gamma-ray and internal plutonium exposures. Accounting for the effects of dose uncertainty markedly increased the width of the confidence intervals for the plutonium dose response but had little impact on the external gamma dose effect estimate. Adjusting risk estimate confidence intervals using CIM provides a solution to the important problem of dose uncertainty. This work demonstrates, for the first time, that it is possible and practical to use our recently developed CIM method to make such adjustments in a large cohort study.

uncertainty, radiation risk estimation, Mayak Prod↗

Final report : multicomponent forensic signature development : interactions with common textiles; mustard precursors and simulants.

2-Chloroethyl phenyl sulfide (CEPS), a surrogate compound of the chemical warfare agent sulfur mustard, was examined using thermal desorption coupled gas chromatography-mass spectrometry (TD/GC-MS) and multivariate analysis. This work describes a novel method of producing multiway data using a stepped thermal desorption. Various multivariate analysis schemes were employed to analyze the data. These methods may be able to discern different sources of CEPS. In addition, CEPS was applied to cotton, nylon, polyester, and silk swatches. These swatches were placed in controlled humidity chambers maintained at 23%, 56%, and 85% relative humidity. At regular intervals, samples were removed from each test swatch, and the samples analyzed using TD/GC-MS. The results were compared across fabric substrate and humidity.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

In Vivo Proton Beam Range Verification Using Spine MRI Changes

Purpose: In proton therapy, uncertainty in the location of the distal dose edge can lead to cautious treatment plans that reduce the dosimetric advantage of protons. After radiation exposure, vertebral bone marrow undergoes fatty replacement that is visible on magnetic resonance imaging (MRI). This presents an exciting opportunity to observe radiation dose distribution in vivo. We used quantitative spine MRI changes to precisely detect the distal dose edge in proton radiation patients. Methods and Materials: We registered follow-up T1-weighted MRI images to planning computed tomography scans from 10 patients who received proton spine irradiation. A radiation dose-MRI signal intensity curve was created using the lateral beam penumbra in the sacrum. This curve was then used to measure range errors in the lumbar spine. Results: In the lateral penumbra, there was an increase in signal intensity with higher dose throughout the full range of 0-37.5 Gy (RBE). In the distal fall-off region, the beam sometimes appeared to penetrate farther than planned. The mean overshoot in 10 patients was 1.9 mm (95% confidence interval, 0.8-3.1 mm), on the order of the uncertainties inherent to our range verification method. Conclusions: We have demonstrated in vivo proton range verification using posttreatment spine MRI changes. Our analysis suggests the presence of a systematic overshoot of a few millimeters in some proton spine treatments, but the range error does not exceed the uncertainty incorporated into the treatment planning margin. It may be possible to extend our technique to MRI sequences that show early bone marrow changes, enabling adaptive treatment modification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Estimation of {alpha}/{beta} for Late Rectal Toxicity Based on RTOG 94-06

Purpose: To estimate {alpha}/{beta}, the parameter ratio from the linear-quadratic (LQ) model, for Grade {>=}2 late rectal toxicity among patients treated on Radiation Therapy Oncology Group (RTOG) protocol 94-06; and to determine whether correcting the rectal dose-volume histogram (DVH) for differences in dose per fraction, based on the LQ model, significantly improves the fit to these data of the Lyman-Kutcher-Burman (LKB) normal-tissue complication probability (NTCP) model. Methods and Materials: The generalized LKB model was fitted to the Grade {>=}2 late rectal toxicity data in two ways: by using DVHs representing physical dose to rectum, and by using a modified approach in which dose bins in the rectal DVH were corrected for differences in dose per fraction using the LQ model, with {alpha}/{beta} estimated as an additional unknown parameter. The analysis included only patients treated with the same treatment plan throughout radiotherapy, so that the dose per fraction to each voxel of rectum could be determined from the DVH. The likelihood ratio test was used to assess whether the fit of the LQ-corrected model was significantly better than the fit of the LKB model based on physical doses to rectum. Results: The analysis included 509 of the 1,084 patients enrolled on RTOG 94-06. The estimate of {alpha}/{beta} from the LQ-corrected LKB model was 4.8 Gy, with 68% confidence interval 0.6 Gy to 46 Gy. The fit was not significantly different from the fit of the LKB model based on physical dose to rectum (p = 0.236). Conclusions: The estimated fractionation sensitivity for Grade {>=}2 late rectal toxicity is consistent with values of {alpha}/{beta} for rectum found previously in human beings and in rodents. However, the confidence interval is large, and there is no evidence that LQ correction of the rectal DVH significantly changes the fit or predictions of the LKB model for this endpoint.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Gaussian CL s method for searches of new physics

Here we describe a method based on the CL s approach to present results in searches of new physics, under the condition that the relevant parameter space is continuous. Our method relies on a class of test statistics developed for non-nested hypotheses testing problems, denoted by ΔT, which has a Gaussian approximation to its parent distribution when the sample size is large. This leads to a simple procedure of forming exclusion sets for the parameters of interest, which we call the Gaussian CL s method. Our work provides a self-contained mathematical proof for the Gaussian CL s method, that explicitly outlines the required conditions. These conditions are milder than that required by the Wilks' theorem to set confidence intervals (CIs). We illustrate the Gaussian CL s method in an example of searching for a sterile neutrino, where the CL s approach was rarely used before. We also compare data analysis results produced by the Gaussian CL s method and various CI methods to showcase their differences.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗