Search NASA⌕ Search

SEARCH · Search NASA

Results for “validation studies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Aerothermodynamic Measurements of Hypersonic Non-Equilibrium Flows

High enthalpy arc-jets are unique facilities particularly suited for producing complex flows in the aerospace field, such as the aerothermodynamics of a re-entry vehicle. Arc-jets are often used to evaluate important design factors that include heat shield materials and vehicle design. Characterization of these facilities is important, as studies often aim to match specific in-flight environments during experiments. Due to the complex environment produced by an arc-jet, with effects such as thermodynamic and chemical non-equilibrium occurring in the flow, characterization experiments are significantly more difficult than in conventional blow-down wind tunnels. The current work aims to characterize an arc-jet facility through spatially-resolved measurements of flow unsteadiness, temperature, and velocity. To achieve this goal, a non-intrusive imaging technique called “planar laser-induced fluorescence” was performed in the NASA Langley Hypersonic Materials Environmental Test System arc-jet facility. The experimental data was analysed to produce the quantitative measurements in multiple regions of the flow around a blunt body specimen. A three-temperature low fidelity numerical solver was created to simulate the flow in order to investigate thermal non-equilibrium effects occurring outside the imaging region in the arc-jet nozzle. Unsteadiness in the test section of the arc-jet was minimized by analyzing a subset of data assessing the gas injection configuration. Radial velocity, rotational temperature and translational temperature measurements are provided that can be used to validate future computational studies. The temperature measurements revealed rotational non-equilibrium occurring behind the bow-shock near the specimen surface. Computational results show the facility is capable of producing thermal non-equilibrium flow in the arc-jet nozzle. This work provides the first experimental and computational evidence of thermal trans-rotational non-equilibrium occurring in multiple regions of this arc-jet facility. Significant improvements to the methodology are also identified as recommendations for future arc-jet characterization studies.

Laser induced fluorescence↗

Preoperative 3-Tesla Multiparametric Endorectal Magnetic Resonance Imaging Findings and the Odds of Upgrading and Upstaging at Radical Prostatectomy in Men With Clinically Localized Prostate Cancer

Purpose: To investigate whether 3-T esla (3T) multiparametric endorectal MRI (erMRI) can add information to established predictors regarding occult extraprostatic or high-grade prostate cancer (PC) in men with clinically localized PC. Methods and Materials: At a single academic medical center, this retrospective study's cohort included 118 men with clinically localized PC who underwent 3T multiparametric erMRI followed by radical prostatectomy, from 2008 to 2011. Multivariable logistic regression analyses in all men and in 100 with favorable-risk PC addressed whether erMRI evidence of T3 disease was associated with prostatectomy T3 or Gleason score (GS) 8-10 (in patients with biopsy GS {<=}7) PC, adjusting for age, prostate-specific antigen level, clinical T category, biopsy GS, and percent positive biopsies. Results: The accuracy of erMRI prediction of extracapsular extension and seminal vesicle invasion was 75% and 95%, respectively. For all men, erMRI evidence of a T3 lesion versus T2 was associated with an increased odds of having pT3 disease (adjusted odds ratio [AOR] 4.81, 95% confidence interval [CI] 1.36-16.98, P=.015) and pGS 8-10 (AOR 5.56, 95% CI 1.10-28.18, P=.038). In the favorable-risk population, these results were AOR 4.14 (95% CI 1.03-16.56), P=.045 and AOR 7.71 (95% CI 1.36-43.62), P=.021, respectively. Conclusions: Three-Tesla multiparametric erMRI in men with favorable-risk PC provides information beyond that contained in known preoperative predictors about the presence of occult extraprostatic and/or high-grade PC. If validated in additional studies, this information can be used to counsel men planning to undergo radical prostatectomy or radiation therapy about the possible need for adjuvant radiation therapy or the utility of adding hormone therapy, respectively.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tropospheric Ozone Assessment Report: Tropospheric Ozone From 1877 to 2016, Observed Levels, Trends and Uncertainties

From the earliest observations of ozone in the lower atmosphere in the 19th century, both measurement methods and the portion of the globe observed have evolved and changed. These methods have different uncertainties and biases, and the data records differ with respect to coverage (space and time), information content, and representativeness. In this study, various ozone measurement methods and ozone datasets are reviewed and selected for inclusion in the historical record of background ozone levels, based on relationship of the measurement technique to the modern UV absorption standard, absence of interfering pollutants, representativeness of the well-mixed boundary layer and expert judgement of their credibility. There are significant uncertainties with the 19th and early 20th-century measurements related to interference of other gases. Spectroscopic methods applied before 1960 have likely underestimated ozone by as much as 11% at the surface and by about 24% in the free troposphere, due to the use of differing ozone absorption coefficients. There is no unambiguous evidence in the measurement record back to 1896 that typical mid-latitude background surface ozone values were below about 20 nmol mol–1, but there is robust evidence for increases in the temperate and polar regions of the northern hemisphere of 30–70%, with large uncertainty, between the period of historic observations, 1896–1975, and the modern period (1990–2014). Independent historical observations from balloons and aircraft indicate similar changes in the free troposphere. Changes in the southern hemisphere are much less. Regional representativeness of the available observations remains a potential source of large errors, which are difficult to quantify. The great majority of validation and intercomparison studies of free tropospheric ozone measurement methods use ECC ozonesondes as reference. Compared to UV-absorption measurements they show a modest (~1–5% ±5%) high bias in the troposphere, but no evidence of a change with time. Umkehr, lidar, and FTIR methods all show modest low biases relative to ECCs, and so, using ECC sondes as a transfer standard, all appear to agree to within one standard deviation with the modern UV-absorption standard. Other sonde types show an increase of 5–20% in sensitivity to tropospheric ozone from 1970–1995. Biases and standard deviations of satellite retrieval comparisons are often 2–3 times larger than those of other free tropospheric measurements. The lack of information on temporal changes of bias for satellite measurements of tropospheric ozone is an area of concern for long-term trend studies.

UV absorption standard↗

Development and Validation of Sensorimotor Assessment Tasks Using Spaceflight Analogs

INTRODUCTION Exploration class missions will require a new level of crew autonomy to self-assess and treat their sensorimotor dysfunction around periods of gravitational transition, where sensorimotor disturbances are at their highest. There is a need to define sensorimotor assessment thresholds that indicate when performance in early extravehicular activities (EVAs) might be impacted or unsafe. The purpose of this study was to develop and validate a set of assessment tasks using sensorimotor spaceflight analogs including the Sensorimotor Disorientation Analog (SDA) and +3G x sustained centrifugation. METHODS For the SDA, forty-one healthy non-astronaut subjects (21 males, 20 females; Mean ± SD, Age: 34.0 ± 7.8 years) volunteered to participate in this study. Subjects attended two testing sessions: 1) familiarization to the tasks and baseline data collection, and 2) tasks completed under two levels of sensorimotor disorientation. Subjects performed a series of seven sensorimotor assessment tasks followed by two operationally relevant EVA analog tasks. The sensorimotor assessments tasks, ordered from least to most provocative of the sensorimotor system, included: postural stability, step test, prone/supine recovery from fall (RFF), four-square-step-test, obstacle negotiation with turns (OTT), kneel-and-reach, and augmented reality full-body coordination. The operational analog tasks included a top-hatch capsule egress and a 5-minute EVA traversal. Disorientation was applied via the SDA which utilized galvanic vestibular stimulation and weighted trunk, wrists, and ankles to target the vestibular and proprioceptive systems such that performance while wearing the SDA mimicked astronaut postflight performance at R+0 and R+1. Sixteen healthy non-astronaut subjects (10 males, 6 females; Age: 35.0 ± 9.5 years) completed +3G x 60-minute sustained centrifugation as an established spaceflight analog replicating the vestibular disruptions seen postflight. Subjects completed a pre-session which included familiarization to the tasks and a 5-minute centrifuge spin. The data collection session included, in order, a baseline data collection, 60-minute centrifuge spin, immediate post-centrifuge data collection, 45-minute seated recovery, and a final data collection. The same assessment and operational analog tasks were conducted as described above. RESULTS Pearsons’ correlation r-values were calculated between assessment and operational analog tasks. The two assessment tasks with the strongest correlations to the operational analog tasks were the RFF (SDA: r≥ 0.57, Centrifuge: r ≥0.55) and OTT (SDA: r≥ 0.66, Centrifuge: r ≥ 0.49). For brevity, repeated measures ANOVA with follow-up paired t-tests are discussed for these two assessment tasks. The SDA found significant differences between all three levels of disorientation for both RFF and OTT (p < 0.001). Significant differences were also found between baseline and immediate post centrifuge testing for both the RFF (p≤ 0.011) and OTT (p = 0.001). Additional results are forthcoming for both disorientation paradigms. DISCUSSION These validation studies provide evidence for down-selection of the assessment tasks that were able to distinguish between levels of sensorimotor disorientation and correlate to performance in operationally relevant tasks for use in upcoming Artemis missions.

S C Moudy↗

Lhermitte Sign After Chemo-IMRT of Head-and-Neck Cancer: Incidence, Doses, and Potential Mechanisms

Purpose: We have observed a higher rate of Lhermitte sign (LS) after chemo-intensity-modulated radiotherapy (IMRT) of head-and-neck cancer than the published rates after conventional radiotherapy. We hypothesized that the inhomogeneous spinal cord dose distributions produced by IMRT caused a 'bath-and-shower' effect, characterized by low doses in the vicinity of high doses, reducing spinal cord tolerance. Methods and Materials: Seventy-three patients with squamous cell carcinoma of the oropharynx participated in a prospective study of IMRT concurrent with weekly carboplatin and paclitaxel. Of these, 15 (21%) reported LS during at least 2 consecutive follow-up visits. Mean dose, maximum dose, and partial volume and absolute volume (in milliliters) of spinal cord receiving specified doses ({>=}10 Gy, {>=}20 Gy, {>=}30 Gy, and {>=}40 Gy), as well as the pattern of dose distributions at the 'anatomic' spinal cord (from the base of the skull to the aortic arch) and 'plan-related' spinal cord (from the top through the bottom of the planning target volumes), were compared between LS patients and 34 non-LS patients. Results: LS patients had significantly higher spinal cord mean doses, V{sub 30}, V{sub 40}, and absolute volumes receiving 30 Gy or more and 40 Gy or more compared with the non-LS patients (p < 0.05). The strongest predictors of LS were higher V{sub 40} and higher cord volumes receiving 40 Gy or more (p {<=} 0.007). There was no evidence of larger spinal cord volumes receiving low doses in the vicinity of higher doses (bath-and-shower effect) in LS compared with non-LS patients. Conclusions: Greater mean dose, V{sub 30}, V{sub 40}, and cord volumes receiving 30 Gy or more and 40 Gy or more characterized LS compared with non-LS patients. Bath-and-shower effects could not be validated in this study as a potential contributor to LS. The higher-than-expected rates of LS may be because of the specific concurrent chemotherapy agents or more accurate identification of LS in the setting of a prospective study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving spot-scanning proton therapy patient specific quality assurance with HPlusQA, a second-check dose calculation engine

Purpose: The purpose of this study was to validate the use of HPlusQA, spot-scanning proton therapy (SSPT) dose calculation software developed at The University of Texas MD Anderson Cancer Center, as second-check dose calculation software for patient-specific quality assurance (PSQA). The authors also showed how HPlusQA can be used within the current PSQA framework.Methods: The authors compared the dose calculations of HPlusQA and the Eclipse treatment planning system with 106 planar dose measurements made as part of PSQA. To determine the relative performance and the degree of correlation between HPlusQA and Eclipse, the authors compared calculated with measured point doses. Then, to determine how well HPlusQA can predict when the comparisons between Eclipse calculations and the measured dose will exceed tolerance levels, the authors compared gamma index scores for HPlusQA versus Eclipse with those of measured doses versus Eclipse. The authors introduce the αβγ transformation as a way to more easily compare gamma scores.Results: The authors compared measured and calculated dose planes using the relative depth, z/R × 100%, where z is the depth of the measurement and R is the proton beam range. For relative depths than less than 80%, both Eclipse and HPlusQA calculations were within 2 cGy of dose measurements on average. When the relative depth was greater than 80%, the agreement between the calculations and measurements fell to 4 cGy. For relative depths less than 10%, the Eclipse and HPlusQA dose discrepancies showed a negative correlation, −0.21. Otherwise, the correlation between the dose discrepancies was positive and as large as 0.6. For the dose planes in this study, HPlusQA correctly predicted when Eclipse had and had not calculated the dose to within tolerance 92% and 79% of the time, respectively. In 4 of 106 cases, HPlusQA failed to predict when the comparison between measurement and Eclipse's calculation had exceeded the tolerance levels of 3% for dose and 3 mm for distance-to-agreement.Conclusions: The authors found HPlusQA to be reasonably effective (79%± 10%) in determining when the comparison between measured dose planes and the dose planes calculated by the Eclipse treatment planning system had exceeded the acceptable tolerance levels. When used as described in this study, HPlusQA can reduce the need for patient specific quality assurance measurements by 64%. The authors believe that the use of HPlusQA as a dose calculation second check can increase the efficiency and effectiveness of the QA process.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-617: A Feasibility Study of Navigation Based Multi Criteria Optimization for Advanced Cervical Cancer IMRT Planning

Purpose: This study aims to validate multi-criteria optimization (MCO) against standard intensity modulated radiation therapy (IMRT) optimization for advanced cervical cancer in RayStation (v2.4, RaySearch Laboratories, Sweden). Methods: 10 advanced cervical cancer patients IMRT plans were randomly selected, these plans were designed with step and shoot optimization, new plans were then designed with MCO based on these plans,while keeping optimization conditions unchanged,comparison was made between both kinds of plans including the dose volume histogram parameters of PTV and OAR,and were analysed by pairing-t test. Results: We normalize the plan so that 95% volume of PTV achieved the prescribed dose(50Gy). The volume of radiation 10, 20, 30, and 40 Gy of the rectum were reduced by 14.7%,26.8%,21.1%,10.5% respectively(P≥0.05). The mean dose of rectum were reduced by 7.2Gy(P≤0.05). There were no significant differences for the dosimetric parameters for the bladder. Conclusion: In comparision with standard IMRT optimization, MCO reduces the dose of organs at risk with the same PTV coverage,but the result needs further clinical evalution.

60 APPLIED LIFE SCIENCES↗

Effects of Mild Hypobaric Hypoxia on Response From Mild Exercise in NASA Exploration Atmosphere Tests

INTRODUCTION: The NASA Exploration Atmosphere study aims to validate a new prebreathe protocol incorporating an alternate habitat atmosphere of 56.5 kPa (8.2psia), 34% O 2 , and 66% N 2 to control and mitigate decompression sickness risk associated with spaceflight extravehicular activities. This alternate atmosphere results in a mild hypoxic environment (PIO 2 of 128 mmHg) that may influence inhabitant physiological responses to exercise. Therefore, the responses to light exercise in relation to the mild hypobaric hypoxic environment were investigated. METHODS: Eight participants (4M/4F; age=38.3±9.0 yr; weight=76.0±13.1 kg; peak aerobic capacity [VO 2 pk]= 3.1±0.7 L/min) were exposed to a mild hypobaric hypoxic environment for 11 days in NASA’s 20-foot hypobaric chamber at Johnson Space Center. Participants alternated test days between a habitat atmosphere of 56.5 kPA/34% O 2 and simulated 6-hour EVA environment, 29.6 kPa/85% O 2 . Participants completed pre-mission graded VO 2 pk tests on a LODE cycle ergometer with ParvoMedics metabolic analyzer. Submaximal aerobic tests were performed pre and during the mission (10-minutes of exercise at a workload of 40% VO 2 pk).Pre-mission, performed submaximal exercise exposed to a breathing air mixture of, 18% O 2 and balance N 2 , to simulate the mildly hypoxic environment within the 20-foot chamber. Linear mixed models (fixed effect: test day; random effects: subject, age) were performed to determine whether physiological responses (oxygen uptake [VO 2 ], carbon dioxide production [VCO 2 ], ventilation [VE], oxygen saturation [SPO 2 ], heart rate [HR], respiratory exchange ratio [RER]) to submaximal exercise performed within the 20-foot hypobaric chamber every 2 days differed from the pre-mission (18% O 2 ) testing. Results are presented as estimated marginal means with lower and upper confidence limits, with significance set to 0.05. RESULTS AND DISCUSSION: Seven of eight participants completed the chamber study. Mixed models for VO 2 , VCO 2 , SpO 2 , HR, and RER indicated negligible impact of the mild hypoxic chamber environment compared to pre-mission testing (all p>0.05).Results for VE indicated a minor impact of chamber environment compared to pre-mission testing (37.0 L/min [30.8, 43.2]), with increased VE at test day 10 (40.4 L/min [34.2, 46.6]; p= 0.029).The aerobic performance data collected suggests limited physiologic responses to mild exercise when performed at normobaric hypoxia and hypobaric hypoxia.

B Siders↗

Fluoride salt static freezing study

Molten salt reactor designs such as the FHR must consider the safety implications of freezing, requiring the development of thermal hydraulics models that account for freezing behavior. Pipe models that couple heat transfer, fluid dynamics, and phase change physics will require verification and validation. A static freezing study is being conducted to provide an initial set of validation data with LiF-BeF{sub 2} (FLiBe). The study will also be performed with LiF-NaF-KF (FLiNaK) in order to quantify the distortion that arises from using FLiNaK as a non-toxic surrogate salt for thermal-hydraulic studies. In order to develop the numerical model, accurate inputs for the thermal hydraulic properties of the two salts of interest need to be measured near the freezing point. For this reason, a series of three experiments including Differential Scanning Calorimetry (DSC) measurements, the Density Measurement Experiment, and the Static Freezing Experiment are being conducted to determine these thermo-physical properties at temperatures near the freezing point. The Static Freezing Experiment is also designed to determine the degree of supercooling that FLiBe and FLiNaK experience. Supercooling is a temperature depression below the freezing point that the liquid experiences before freezing initiates. Increased supercooling in a liquid flowing through a pipe leads to increased dendritic freezing and an increased likelihood of pipe blockage and freeze-shut. Based on previous research on supercooling in water and non-fluoride salts, supercooling is likely affected most strongly by cooling rate and sample size (as well as salt purity). No data has been generated previously on supercooling in fluoride salts such as FLiBe and FLiNaK. The results of this set of DSC, Density Measurement and Static Freezing experiments will be used in an ongoing fluoride salt freezing study being conducted to develop pipe freezing models for molten salts to be used in safety analysis. The thermal hydraulic properties measured in this study will serve as inputs for all future models. With the supercooling behavior of both salts quantified, it can be assessed whether supercooling must be included in future thermal hydraulic models. The validated Static Freezing Experiment model can then serve as the framework for a pipe freezing model and eventually a 1D system code.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Physics-based hybrid machine learning for critical heat flux prediction with uncertainty quantification

Critical heat flux (CHF) is a key quantity in nuclear system modeling due to its impact on heat transfer, safety margins, and reactor performance. This study develops and validates an uncertainty-aware hybrid modeling approach that combines machine learning with physics-based models to predict CHF in cases of dryout. The Biasi and Bowring empirical correlations were paired with three ML uncertainty quantification (UQ) techniques: deep neural network (DNN) ensembles, Bayesian neural networks (BNNs), and deep Gaussian processes (DGPs). A pure ML model without a base model was evaluated for comparison. Model performance was assessed under plentiful (7,350 points) and limited (9 points) training data scenarios using parity, uncertainty distributions, and calibration curves. Results show that the Biasi hybrid DNN ensemble achieved the best overall performance, with a mean absolute relative error of 1.846%, and well-calibrated uncertainty estimates. The BNN-based hybrids showed slightly higher error (2.14%) but superior uncertainty calibration. DGP models underperformed, with over 6% error and poor uncertainty calibration. All hybrid models outperformed pure machine learning configurations, demonstrating resistance against data scarcity. These findings indicate that hybrid modeling significantly improves predictive accuracy, interpretability, and resilience to data scarcity. The integration of uncertainty awareness provides actionable confidence in CHF predictions, which is vital for safety-critical decisions in nuclear applications. This hybrid approach offers a viable pathway for deploying ML models in reactor analysis tools while preserving domain knowledge and physical consistency.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Scaling Study of Microbially-Enhanced Methane Production From Coal (Mecbm): Optimizing Nutrient Delivery For Maximized Methane Production

Microbially-enhanced coalbed methane (MECBM) recovery is a novel method to stimulate gas production in CBM reservoirs. We first develop suitable nutrient recipes for native coals from sites each in the Illinois Basin and in the San Juan Basin. The optimal concentrations for statistically significant parameters are identified and the methane yields at laboratory scale are obtained (Part I & II). We then demonstrate the importance of replicating truly in-situ conditions for bio- gasification studies by investigating methane productivity in a core holder simulating in-situ conditions. Based on the experimental results, the resulting gas production correlates positively with the permeability of the samples. We examine the deliverability of engineered microbial solutions to promote coal bioconversion in coals and demonstrate that greater than milli-darcy permeability is required under in-situ stress conditions (Part III). This constraint is supplemented by imaging and a fractal-based characterization approach to evaluate changes in the physical properties of coal due to bio-gasification. High resolution SEM imaging is used to observe swelling of the coal matrix with sub-micron wide continuous pores observed to persist even after microbial treatment (IV). We explore the potential of generating, propping-open and sustaining the functionality of hydraulic fractures in coal using different fracturing fluids (Part V). The alteration of the nano-pore structure due to MECBM treatment is examined by using small angle X-ray scattering (SAXS) to define the in-situ porosity evolution as a proxy to infer permeability evolution (Part VI). Coupled hydro-mechanical and bio-gasification modeling is applied to determine the effectiveness of nutrient delivery by hydraulic fracturing and its field implementation. Compared with both the unstimulated and hydro-shear-dilated cases of the natural fracture network, hydraulic fracturing demonstrates a significant improvement to enhance nutrient delivery. A preliminary analysis of field-scale methane yield is completed with consideration of the combined influence of permeability evolution, solute transport and microbial growth (Part VII). Developing nutrient solutions for Illinois Basin and San Juan Basin (Task 2): To enhance methane release from coal through bio-gasification, suitable nutrient solutions are needed to stimulate microbial activities toward coal depolymerization and conversion to biogas. Specific for bituminous coal in the Illinois basin, a nutrient recipe that can be used to enhance coal bio- gasification in situ is developed. Based on our previous experience working with Illinois coal and the characteristics of the formation water and the indigenous microbial community, four parameters, Fe powder, methanol, ethanol, and trace minerals are optimized through using a Box-Behnken design. The optimal condition predicted by the models is: Fe-powder at 74 mM, methanol at 97.91 mM, ethanol at 100 mM, and trace minerals at 100%. Under these conditions, the predicted methane yield and content is 1,417.35 ft 3 /ton and 80.7%, respectively. These results are then validated by experimental studies. In addition, each added component is evaluated in terms of its contribution to methane generated. Specifically, the role of coal in the bio-gasification process is studied against two other solid materials. Experimental data from different solid matrices prove that coal is indeed degraded by the studied microbial community.

01 COAL, LIGNITE, AND PEAT↗

Validation of the SCALE/Polaris-PARCS Code Procedure with the ENDF/B-VII.1 AMPX 56-Group Library: Pressurized Water Reactor

This study was conducted to validate the SCALE/Polaris v6.3.0–PARCS v3.4.2 code procedure with the Evaluated Nuclear Data File (ENDF)/B-VII.1 AMPX 56-group library for pressurized water reactor (PWR) analysis, by comparing simulated results with measured data for critical experiments and operating PWRs. Uncertainties of the SCALE/Polaris–PARCS code procedure for PWR analysis were evaluated in the validation for the PWR key nuclear parameters such as critical boron concentrations, reactivity, control bank work, temperature coefficients, and pin and assembly power peaking factors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Comparing deflection measurements of a magnetically steerable catheter using optical imaging and MRI

Purpose: Magnetic resonance imaging (MRI) is an emerging modality for interventional radiology, giving clinicians another tool for minimally invasive image-guided interventional procedures. Difficulties associated with endovascular catheter navigation using MRI guidance led to the development of a magnetically steerable catheter. The focus of this study was to mechanically characterize deflections of two different prototypes of the magnetically steerable catheterin vitro to better understand their efficacy. Methods: A mathematical model for deflection of the magnetically steerable catheter is formulated based on the principle that at equilibrium the mechanical and magnetic torques are equal to each other. Furthermore, two different image based methods for empirically measuring the catheter deflection angle are presented. The first, referred to as the absolute tip method, measures the angle of the line that is tangential to the catheter tip. The second, referred to the base to tip method, is an approximation that is used when it is not possible to measure the angle of the tangent line. Optical images of the catheter deflection are analyzed using the absolute tip method to quantitatively validate the predicted deflections from the mathematical model. Optical images of the catheter deflection are also analyzed using the base to tip method to quantitatively determine the differences between the absolute tip and base to tip methods. Finally, the optical images are compared to MR images using the base to tip method to determine the accuracy of measuring the catheter deflection using MR. Results: The optical catheter deflection angles measured for both catheter prototypes using the absolute tip method fit very well to the mathematical model (R{sup 2} = 0.91 and 0.86 for each prototype, respectively). It was found that the angles measured using the base to tip method were consistently smaller than those measured using the absolute tip method. The deflection angles measured using optical data did not demonstrate a significant difference from the angles measured using MR image data when compared using the base to tip method. Conclusions: This study validates the theoretical description of the magnetically steerable catheter, while also giving insight into different methods and modalities for measuring the deflection angles of the prototype catheters. These results can be used to mechanically model future iterations of the design. Quantifying the difference between the different methods for measuring catheter deflection will be important when making deflection measurements in future studies. Finally, MR images can be used to reliably measure deflection angles since there is no significant difference between the MR and optical measurements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Defining the mechanistic binding of viral particles to a multi‐modal anion exchange resin

A multi‐tiered approach to determine the binding mechanism of viral clearance utilizing a multi‐modal anion exchange resin was applied to a panel of four viral species that are typically used in validating viral clearance studies (i.e., X‐MuLV, MVM, REO3, and PrV). First, virus spiked buffer‐only experiments were conducted to evaluate the virus's affinity for single mode and multi‐modal chromatography resins under different buffer conditions in a chromatography column setting. From these results we hypothesize that the mechanisms of binding of the viruses involve binding to both the hydrophobic and anionic functional groups. This mechanistic view agreed with the general surface characteristics of the different virus species in terms of isoelectric point and relative hydrophobicity values. This hypothesized mechanistic binding was then tested with commercially relevant, in‐process materials, in which competitive binding occurred between the load components (e.g., viruses, target product, and impurities) and the resin. © 2018 American Institute of Chemical Engineers Biotechnol. Prog. , 34:1019–1026, 2018

Brown, Matthew R.↗

Modeling Planar Electrodes and Zero–Gap Membrane Electrode Assemblies for CO 2 Electrolysis

Multiphysics modeling enables probing of conditions inside a CO 2 electrolyzer that are difficult to measure, such as local concentrations and pH, as well as rapid testing of possible design changes. A one-dimensional model for a zero-gap membrane electrode assembly (MEA) CO 2 electrolyzer was developed with the assumption that catalyst layers interact with the membrane ionomer such that the ionomer affects the underlying kinetics. The kinetics for bicarbonate reacting to form hydrogen are fit using a planar electrode model for silver with an ionomer coating. The MEA model results are validated against experimental studies for current density and product selectivity. Flooding of the cathode is modeled using saturation curves, and results show that blocked pores in the microporous layer play a significant role in limiting the mass transport at high potentials (>2.8 V). Sensitivity studies showed that CO Faradaic efficiency can be increased by decreasing catalyst layer thickness and porosity, and decreasing KHCO 3 concentration.

30 DIRECT ENERGY CONVERSION↗

The Twentieth Century Reanalysis Project

The Twentieth Century Reanalysis (20CR) project is an international effort to produce a comprehensive global atmospheric circulation dataset spanning the twentieth century, assimilating only surface pressure reports and using observed monthly sea-surface temperature and sea-ice distributions as boundary conditions. It is chiefly motivated by a need to provide an observational dataset with quantified uncertainties for validations of climate model simulations of the twentieth century onall time-scales,with emphasisonthe statistics of daily weather. It uses an Ensemble Kalman Filter data assimilation method with background ‘first guess’ fields supplied by an ensemble of forecasts from a global numerical weather prediction model. This directly yields a global analysis every 6 hours as the most likely state of the atmosphere, and also an uncertainty estimate of that analysis. The 20CR dataset provides the first estimates of global tropospheric variability, and of the dataset’s time-varying quality, from 1871 to the present at 6-hourly temporal and 2° spatial resolutions. Intercomparisons with independent radiosonde data indicate that the reanalyses are generally of high quality. The quality in the extratropical Northern Hemisphere throughout the century is similar to that of current three-day operational NWP forecasts. Intercomparisons over the second half-century of these surface-based reanalyses with other reanalyses that also make use of upper-air and satellite data are equally encouraging. It is anticipated that the 20CR dataset will be a valuable resource to the climate research community for both model validations and diagnostic studies. Some surprising results are already evident. For instance, the long-term trends of indices representing the North Atlantic Oscillation, the tropical Pacific Walker Circulation, and the Pacific–North American pattern are weak or non-existent over the full period of record. The long-term trends of zonally averaged precipitation minus evaporation also differ in character from those in climate model simulations of the twentieth century.

Meteorology & Atmospheric Sciences↗

$T\overline{T}$-deformed free energy of the Airy model

Sharpening the correspondence of Jackiw-Teitelboim (JT) gravity and its dual matrix model description at a finite radial cutoff λ through the $T\overline{T}$ deformation is of interest. To proceed, we simplify the problem by considering the Airy model and deform Airy correlators in the same way as in $T\overline{T}$ -deformed JT gravity. We use those correlators to compute the annealed and quenched free energies for both λ > 0 and λ < 0 from an integral representation of the replica trick. At the leading order in λ and low temperatures, we confirm that the genus-zero quenched free energy monotonically decreases as a function of temperature when perturbation theory is valid. We then study the all-genus quenched free energy at low temperatures, where we discover and discuss subtleties due to non-perturbative effects in the Airy model, as well as the contributions from the non-perturbative branch under the $T\overline{T}$ deformation.

2D gravity↗