Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Performance of positive ion based high power ion source of EAST neutral beam injector

The positive ion based source with a hot cathode based arc chamber and a tetrode accelerator was employed for a neutral beam injector on the experimental advanced superconducting tokamak (EAST). Four ion sources were developed and each ion source has produced 4 MW @ 80 keV hydrogen beam on the test bed. 100 s long pulse operation with modulated beam has also been tested on the test bed. The accelerator was upgraded from circular shaped to diamond shaped in the latest two ion sources. In the latest campaign of EAST experiment, four ion sources injected more than 4 MW deuterium beam with beam energy of 60 keV into EAST.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Determining the detection efficiency of excited neutral atoms by a microchannel plate detector

We present a method for determining the detection efficiency of neutral atoms relative to keV ions. Excited D* atoms are produced by D{sub 2} fragmentation in a strong laser field. The fragments are detected by a micro-channel plate detector either directly as neutrals or as keV ions following field ionization and acceleration by a static electric field. Moreover, we propose a new mechanism by which neutrals are detected. We show that the ratio of the yield of neutrals and ions can be related to the relative detection efficiency of these species.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temperature Profile of the Solution Vessel of an Accelerator-Driven Subcritical Fissile Solution System

Dynamic System Simulation (DSS) models of fissile solution systems have been developed and verified against a variety of historical configurations. DSS techniques have been applied specifically to subcritical accelerator-driven systems using fissile solution fuels of uranium. Initial DSS models were developed in DESIRE, a specialized simulation scripting language. In order to tailor the DSS models to specifically meet needs of system designers they were converted to a Visual Studio implementation, and one of these subsequently to National Instrument’s LabVIEW for human factors engineering and operator training. Specific operational characteristics of subcritical accelerator-driven systems have been examined using a DSS model tailored to this particular class using fissile fuel.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A polyvalent harmonic coil testing method for small-aperture magnets

A method to characterize permanent and fast-pulsed iron-dominated magnets with small apertures is presented. The harmonic coil measurement technique is enhanced specifically for small-aperture magnets by (1) in situ calibration, for facing search-coil production inaccuracy, (2) rotating the magnet around its axis, for correcting systematic effects, and (3) measuring magnetic fluxes by stationary coils at different angular positions for measuring fast pulsed magnets. This method allows a quadrupole magnet for particle accelerators to be characterized completely, by assessing multipole field components, magnetic axis position, and field direction. In this paper, initially the metrological problems arising from testing small-aperture magnets are highlighted. Then, the basic ideas of the proposed method and the architecture of the corresponding measurement system are illustrated. Finally, experimental validation results are shown for small-aperture permanent and fast-ramped quadrupole magnets for the new linear accelerator Linac4 at CERN (European Organization for Nuclear Research).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multicentimeter long high density magnetic plasmas for optical guiding

We present a platform for producing long plasma channels suitable for guiding lasers over several centimeters by applying magnetic fields to limit the radial heat flux from a preforming laser beam. The resulting density gradient will be used as an optical plasma waveguide. The plasma conditions have been chosen to be consistent with the requirements for laser wakefield acceleration where multi-GeV electrons are predicted. A detailed description of the system used to produce the high (5 T) magnetic fields and initial results that show a 5 cm long plasma column are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prototyping of beam position monitor for medium energy beam transport section of RAON heavy ion accelerator

A heavy ion accelerator, RAON is going to be built by Rare Isotope Science Project in Korea. Its target is to accelerate various stable ions such as uranium, proton, and xenon from electron cyclotron resonance ion source and some rare isotopes from isotope separation on-line. The beam shaping, charge selection, and modulation should be applied to the ions from these ion sources because RAON adopts a superconducting linear accelerator structure for beam acceleration. For such treatment, low energy beam transport, radio frequency quadrupole, and medium energy beam transport (MEBT) will be installed in injector part of RAON accelerator. Recently, development of a prototype of stripline beam position monitor (BPM) to measure the position of ion beams in MEBT section is under way. In this presentation, design of stripline, electromagnetic (EM) simulation results, and RF measurement test results obtained from the prototyped BPM will be described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Acceleration of heavy ions in inverse free electron laser

In conventional linear accelerators, the beam is accelerated with a synchronous harmonic of the radio frequency field where the electric field component is collinear with the beam direction. This approach requires the design of complex accelerating structures, especially for low-energy heavy ions. If the beam motion were sustainably coupled to transverse electromagnetic fields, this could significantly simplify the accelerating structure design, and even allow acceleration with free-space waves. However, despite the long history of the proposed concept for accelerating low-velocity ion beams, it has not found practical application, partially because of the complexity of the technical design. In this paper, we present a practical design approach for this undulator-based accelerator for low-energy heavy-ions, reminiscent of the inverse free electron laser operating principle, but in a different parameter space.

47 OTHER INSTRUMENTATION↗

Advanced Laboratory and Field Arrays (ALFA)/Lab Collaboration Project (LCP) for Marine Energy (Final Scientific/Technical Report)

The objective of the Advanced Laboratory and Field Arrays (ALFA) project was to reduce the Levelized Cost of Energy (LCOE) of Marine and Hydrokinetic (MHK) energy by leveraging research, development, and testing capabilities at Oregon State University, University of Washington, and the University of Alaska, Fairbanks. ALFA is a project within the Pacific Marine Energy Center (PMEC; formerly NNMREC), a multi-institution entity with a diverse funding base that focuses on research and development for marine renewables. The ALFA project aimed to accelerate the development of next-generation arrays of wave energy conversion (WEC) and tidal energy conversion (TEC) devices through a suite of field-focused R&D activities spanning a broad range of strategic opportunity areas identified in the Funding Opportunity Announcement: • Device and/or array operation and maintenance (O&M) logistics development; • High-fidelity resource characterization and/or modeling technique development and validation; • Array-specific component technology development (e.g. moorings and foundations, transmission, and other offshore grid components); • Array performance testing and evaluation; and • Novel cost-effective environmental monitoring techniques and instrumentation testing and evaluation. The objective of the Lab Collaboration Project (LCP) was to accelerate the development of next-generation marine energy conversion systems. The LCP aimed to achieve these project objectives in collaboration with the national laboratories by: • Developing concept generation and assessment tools; • Improving access to existing testing resources; • Validating collision risk models between fish and turbines; and • Advancing analysis and simulation capabilities for wave-WEC interactions and PTO analysis in nonlinear ocean waves. The ALFA portion of the project was comprised of six overarching technical tasks: • Task 1: Debris Modeling, Detection and Mitigation; • Task 2: Autonomous Monitoring & Intervention; • Task 3: Resource Characterization for Extreme Conditions; • Task 4: Robust Models for Design of Offshore Anchoring and Mooring Systems; • Task 5: Performance Enhancement for Marine Energy Converter (MEC) Arrays; and • Task 6: Evaluating Sampling Techniques for MHK Biological Monitoring. The LCP was divided into four overarching technical tasks: • Task 7: Project Management and Reporting • Task 8: Novel Design and Assessment Methodologies for Wave Energy Converter Design (Wave- SPARC) • Task 9: Testing Access for Commercial Marine Renewable Energy Technology Developers • Task 10: Quantifying Collision Risk for Fish and Turbines • Task 11: Nonlinear Ocean Waves and PTO Control Strategy Each ALFA/LCP task listed above functioned as a separate and discreet project. A final Technical Report was written for each individual task and these reports were uploaded to OSTI, after receiving DOE approval. The following document is a compilation of each of these final, approved reports arranged as individual chapters.

13 HYDRO ENERGY↗

TU-FG-201-09: Predicting Accelerator Dysfunction

Purpose: To develop an integrated statistical process control (SPC) framework using digital performance and component data accumulated within the accelerator system that can detect dysfunction prior to unscheduled downtime. Methods: Seven digital accelerators were monitored for twelve to 18 months. The accelerators were operated in a ‘run to failure mode’ with the individual institutions determining when service would be initiated. Institutions were required to submit detailed service reports. Trajectory and text log files resulting from a robust daily VMAT QA delivery were decoded and evaluated using Individual and Moving Range (I/MR) control charts. The SPC evaluation was presented in a customized dashboard interface that allows the user to review 525 monitored parameters (480 MLC parameters). Chart limits were calculated using a hybrid technique that includes the standard SPC 3σ limits and an empirical factor based on the parameter/system specification. The individual (I) grand mean values and control limit ranges of the I/MR charts of all accelerators were compared using statistical (ranked analysis of variance (ANOVA)) and graphical analyses to determine consistency of operating parameters. Results: When an alarm or warning was directly connected to field service, process control charts predicted dysfunction consistently on beam generation related parameters (BGP)– RF Driver Voltage, Gun Grid Voltage, and Forward Power (W); beam uniformity parameters – angle and position steering coil currents; and Gantry position accuracy parameter: cross correlation max-value. Control charts for individual MLC – cross correlation max-value/position detected 50% to 60% of MLCs serviced prior to dysfunction or failure. In general, non-random changes were detected 5 to 80 days prior to a service intervention. The ANOVA comparison of BGP determined that each accelerator parameter operated at a distinct value. Conclusion: The SPC framework shows promise. Long term monitoring coordinated with service will be required to definitively determine the effectiveness of the model. Varian Medical System, Inc. provided funding in support of the research presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase-contrast imaging and tomography at 60 keV using a conventional x-ray tube source

Phase-contrast imaging at laboratory-based x-ray sources using grating interferometers has been developed over the last few years for x-ray energies of up to 28 keV. Here, we show first phase-contrast projection and tomographic images recorded at significantly higher x-ray energies, produced by an x-ray tube source operated at 100 kV acceleration voltage. We find our measured tomographic phase images in good agreement with tabulated data. The extension of phase-contrast imaging to this significantly higher x-ray energy opens up many applications of the technique in medicine and industrial nondestructive testing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Space radiation simulation using blowout plasma wakes at the SAMURAI Lab

We discuss the creation of broadband electron energy spectra using plasma wakefield acceleration at the SAMURAI Lab as part of the UCLA Particle Beam Physics Laboratory group. As the exploration and development of space increases, it will become important to efficiently replicate radiation conditions that exist in low earth orbit and planetary space. Missions such as satellite deployment and exploration of other planets, i.e. the Juno probe launched to explore Jupiter [1], require electronics that are able to withstand the electron radiation spectrum present in these locations. This requires Earth-based testing for development of robust electronics with respect to electron radiation exposure. Conventional accelerators are poorly suited for this purpose because they are designed for monoenergetic electron beams. Current simulation schemes involve the interpolation of discrete exposure tests, with time structures entirely different from space events. This idea poorly captures the radiation damage physics seen in the real world. Conversely, the wakefields produced in the blowout regime of beam plasma wakefield accelerators can be used to create the full spectrum of space radiation including high energy “killer” electrons by injecting a long bunch to excite the plasma blowout. With a long bunch ( k p σ z ≈ 2 ) the beam will feel both accelerating and decelerating fields, resulting in an exponential or power law energy spectrum distribution seen in regions outside the Earth and Jupiter. This can be achieved at the new SAMURAI lab at UCLA resulting in broadband energy spectra with maximum energies up to 100 MeV that correctly reflect the radiative conditions of space in low Earth orbit and around Jupiter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Theoretical and numerical analyses of a slit-masked chicane for modulated bunch generation

Density modulations on electron beams can improve machine performance of beam-driven accelerators and FELs with resonance beam-wave coupling. The beam modulation is studied with a masked chicane by the analytic model and simulations with the beam parameters of the Fermilab Accelerator Science and Technology (FAST) facility. With the chicane design parameters (bending angle of 18o, bending radius of 0.95 m and R 56 ~ –0.19 m) and a nominal beam of 3 ps bunch length, the analytic model showed that a slit-mask with slit period 900 μ m and aperture width 300 μ m induces a modulation of bunch-to-bunch spacing ~ 100 μ m to the bunch with 2.4% correlated energy spread. With the designed slit mask and a 3 ps bunch, particle-in-cell (PIC) simulations, including nonlinear energy distributions, space charge force, and coherent synchrotron radiation (CSR) effect, also result in beam modulation with bunch-to-bunch distance around 100 μ m and a corresponding modulation frequency of 3 THz. The beam modulation has been extensively examined with three different beam conditions, 2.25 ps (0.25 nC), 3.25 ps (1 nC), and 4.75 ps (3.2 nC), by tracking code Elegant. The simulation analysis indicates that the sliced beam by the slit-mask with 3 ~ 6% correlated energy spread has modulation lengths about 187 μ m (0.25 nC), 270 μ m (1 nC) and 325 μ m (3.2 nC). As a result, the theoretical and numerical data proved the capability of the designed masked chicane in producing modulated bunch train with micro-bunch length around 100 fs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved technique for preparation of deuterated-polyethylene targets

An improved method for preparation of self-supporting deuterated polyethylene targets using solvent casting technique is described. The improved method provides recommendations for solvent heating, solvent casting of the thin film, and subsequent heating treatment which is shown to greatly enhance the overall target strength and durability as needed for accelerator experiments. A detailed characterization using both optical and electron microscopy, differential scanning calorimetry, and Fourier transform infrared spectroscopy demonstrates the improvements using the post-casting heating treatment. The effects of heavy ion-induced target degradation and recommendations for use under these conditions is also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inner surface flash-over of insulator of low-inductance high-voltage self-breakdown gas switch and its application

In this paper, the inner surface flash-over of high-voltage self-breakdown switch, which is used as a main switch of pulse modulator, is analyzed in theory by employing the method of distributed element equivalent circuit. Moreover, the field distortion of the switch is simulated by using software. The results of theoretical analysis and simulation by software show that the inner surface flash-over usually starts at the junction points among the stainless steel, insulator, and insulation gas in the switch. A switch with improved structure is designed and fabricated according to the theoretical analysis and simulation results. Several methods to avoid inner surface flash-over are used to improve the structure of switch. In experiment, the inductance of the switch is no more than 100 nH, the working voltage of the switch is about 600 kV, and the output voltage and current of the accelerator is about 500 kV and 50 kA, respectively. And the zero-to-peak rise time of output voltage at matched load is less than 30 ns due to the small inductance of switch. The original switch was broken-down after dozens of experiments, and the improved switch has been worked more than 200 times stably.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PAMELA’S MEASUREMENTS OF MAGNETOSPHERIC EFFECTS ON HIGH-ENERGY SOLAR PARTICLES

The nature of particle acceleration at the Sun, whether through flare reconnection processes or through shocks driven by coronal mass ejections, is still under scrutiny despite decades of research. The measured properties of solar energetic particles (SEPs) have long been modeled in different particle-acceleration scenarios. The challenge has been to disentangle the effects of transport from those of acceleration. The Payload for Antimatter Matter Exploration and Light-nuclei Astrophysics (PAMELA) instrument enables unique observations of SEPs including the composition and angular distribution of the particles about the magnetic field, i.e., pitch angle distribution, over a broad energy range (>80 MeV)—bridging a critical gap between space-based and ground-based measurements. We present high-energy SEP data from PAMELA acquired during the 2012 May 17 SEP event. These data exhibit differential anisotropies and thus transport features over the instrument rigidity range. SEP protons exhibit two distinct pitch angle distributions: a low-energy population that extends to 90° and a population that is beamed at high energies (>1 GeV), consistent with neutron monitor measurements. To explain a low-energy SEP population that exhibits significant scattering or redistribution accompanied by a high-energy population that reaches the Earth relatively unaffected by dispersive transport effects, we postulate that the scattering or redistribution takes place locally. We believe that these are the first comprehensive measurements of the effects of solar energetic particle transport in the Earth’s magnetosheath.

79 ASTRONOMY AND ASTROPHYSICS↗

Spin Physics Capability with Silicon Vertex Tracker for PHENIX

The PHENIX detector is being upgraded with a silicon vertex tracker (VTX) to enhance physics capability both in spin physics and heavy ion physics. In order to check the performance of the VTX, PYTHIA simulation was performed with gamma-jet production events under the condition of center-of-mass energy of 500 GeV and the integrated luminosity of 300 pb{sup -1}. We will report the simulation results of a longitudinal double-spin asymmetry A{sub LL} with the VTX.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

{pi} p and {pi}{pi} scattering at LHC

Can we get the information on {pi} p and {pi}{pi} scattering from the LHC data? We present briefly recent results of the IHEP Diffractive Group, which include all the steps: formulation of the problem, an idea how to solve it, experimental tools, Monte-Carlo simulation and preliminary expectations concerning the first data from the LHC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

J-PARC, facility for hadron physics, the present status and future

J-PARC was almost completed in early 2009 and started its operational era. Hadron Experimental Facility is one of the world-wide research centers for nuclear and hadron physics. The present status of the beamline and spectrometers as well as the physics program for nuclear and hadron physics is described. New beamline and experiments there are also introduced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗