SEARCH · Search NASA
Results for “Building controls”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
A Mathematical Framework for the Analysis of Cyber-Resilient Control Systems
The increasingly recognized vulnerability of industrial control systems to cyber-attacks has inspired a considerable amount of research into techniques for cyber-resilient control systems. The majority of this effort involves the application of well known information security (IT) techniques to control system networks. While these efforts are important to protect the control systems that operate critical infrastructure, they are never perfectly effective. Little research has focused on the design of closed-loop dynamics that are resilient to cyber-attack. The majority of control system protection measures are concerned with how to prevent unauthorized access and protect data integrity. We believe that the ability to analyze how an attacker can effect the closed loop dynamics of a control system configuration once they have access is just as important to the overall security of a control system. To begin to analyze this problem, consistent mathematical definitions of concepts within resilient control need to be established so that a mathematical analysis of the vulnerabilities and resiliencies of a particular control system design methodology and configuration can be made. In this paper, we propose rigorous definitions for state awareness, operational normalcy, and resiliency as they relate to control systems. We will also discuss some mathematical consequences that arise from the proposed definitions. The goal is to begin to develop a mathematical framework and testable conditions for resiliency that can be used to build a sound theoretical foundation for resilient control research.
Low Carbon Technology Strategies: Large Office
This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon large office buildings within their existing building portfolios. Large offices are typically over 50,000 square feet and often include complex heating and cooling systems.
Performance assessment of a real water source heat pump within a hardware-in-the-loop (HIL) testing environment
Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while also maintaining the thermal comfort of building occupants. As the pivotal point between building electricity consumption and indoor thermal comfort, high-efficiency electrical vapor-compression heat pumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on heat pump operation and performance when subjected to different weather conditions, building loads, and grid requests calls for investigation and verification via experimental testing with actual heat pumps integrated with real-time building and grid responses. This study introduces a Water-Source Heat Pump (WSHP) Hardware-in-The-Loop (HIL) Test Facility that is the first of its kind. This testbed utilizes a 2-ton variable speed water-to-air heat pump that is capable of interacting with a virtual environment currently comprised of an EnergyPlus (E+) building simulation, an agent-based occupant behavioral model, and a single U-tube ground-loop heat exchanger (GLHE) model. Detailed descriptions of the testbed’s physical design and operation, virtual environment, as well as their mutual communication is provided. An uncertainty analysis is also performed under manufacturer specified heating and cooling design conditions. This analysis shows that the total load across the WSHP’s demand side heat exchanger, i.e., the sum of its latent and sensible components, can be measured with a relative uncertainty of ± 10.4% and ± 3.6% in cooling and heating mode respectively. The WSHP’s coefficient of performance (COP) can be measured with relative uncertainties of ± 10.4% in cooling mode, and ± 3.7% in heating mode. A preliminary 24-h experimental demonstration is then performed utilizing the DOE prototype small commercial office building model in E+. The simulation takes place in Atlanta, GA on the date of 08/26/15 from 12:00 AM to 11:59 PM using TMY3 weather data. Here, the results from this demonstration show that over the course of this experiment the simulated outputs of zone dry-bulb temperature, zone humidity ratio, and WSHP inlet water temperature can be tracked by testbed emulators up to a root mean squared error (RMSE) of ± 0.27 °C, ± 0.376 g/kg, and ± 0.85 °C respectively. The WSHP’s dynamic behavioral characteristics and performance are also captured, and correspond well with the authors’ previous understanding of heat pump efficiency as a function of evaporator and condenser fluid inlet conditions respectively.
GT Flex: A Coordinated Multi-Building Pilot Study
Buildings are a significant and untapped resource for providing utility electric grid services. Recent studies have estimated that buildings could reduce the peak demand on the electric grid in the U.S. by almost 25% through effective combinations of energy efficiency (EE) measures and load flexibility strategies (Langevin et al. 2021). The U.S. Department of Energy (DOE) has established a goal to triple energy efficiency and demand flexibility in both residential and commercial sections by 2030 compared to 2020 levels (Satchwell et al. 2021). Such findings place buildings alongside electric vehicles, photovoltaics, electric batteries, and other distributed energy resources (DERs) as primary technologies needed for supporting high renewable energy generation grids. Coordinating and optimizing multiple buildings and other DERs is more beneficial and valuable when compared with individual buildings and DERs operating as siloed resources, uncoordinated with others (Olgyay et al. 2020). A pilot study at the Georgia Institute of Technology (GIT) was conducted to evaluate value propositions of a multi-building scale project seeking carbon reduction, energy efficiency and grid-interactive capabilities, by demonstrating the means by which stakeholders can determine the technical and financial merits of grid-interactivity and energy efficiency technologies coordinated across multiple assets. The study focused on analyzing technical feasibility of deploying thermal load flexibility strategies at the multi-building scale, coordinated to not exceed existing infrastructure constraints at the pilot site. Results show that campus can provide 3-3.5 MW of potential load shed over a 4-hour event window through coordinated dispatch of thermal cooling load flexibility without exceeding existing infrastructure capacities. Under future high renewable scenarios, this thermal flexibility resource is also valuable when coordinated to reduce curtailment of intermittent renewables. Economic analyses were performed to effectively communicate various value propositions of grid-interactive and efficient building (GEB) thermal flexibility strategies. Load flexibility presents a financial value proposition to the campus today. By conducting rationalized, coordinated dispatch in response to real time price (RTP) fluctuations, the campus can benefit materially from daily price arbitrage. The RTP signal acts as an aggregating mechanism between the utility and customer to call on demand flexibility resources, with a large portion of the benefit deriving from a relatively small number of days. Realizing and maximizing this benefit with thermal load flexibility requires careful attention to the timing of pricing signals and parameterization of dispatch to overcome efficiency penalties. Grid value and signals are expected to evolve over time, and thermal load flexibility shows potential to adapt dispatch logic to support intermittent renewable generation.
System for Photogrammetric Imaging, Detection, and Ranging (SPIDR)
The System for Photogrammetric Imaging, Detection, and Ranging (SPIDR) project aims to advance the state-of-the-art (SOA) technology in camera tracking. SPIDR will advance this technology in the following ways: 1) perform autonomous tracking of rocket launches, 2) allow modularity for camera payloads to enable various types of imagery capture (standard video, high-speed, infrared, etc.), 3) enable additional imagery assets for increased scope of imagery analysis, and 4) serve as a viable tracking replacement for the existing Kineto Tracking Mount (KTM) system used by the Exploration Ground Systems (EGS) program. The project initially aimed to build an in-house mechanical design and control system, but realigned to a commercial off-the-shelf (COTS) mechanical design. During the FY23 CIF timeline, the SPIDR team made significant advances in building a machine-learning (ML) based object detection model for various rockets and their plumes. The team will continue advancing the model, and begin work on the pan and tilt unit (PTU) control system and tracking algorithm development.
An Assessment of IMPAC - Integrated Methodology for Propulsion and Airframe Controls
This report documents the work done under a NASA sponsored contract to transition to industry technologies developed under the NASA Lewis Research Center IMPAC (Integrated Methodology for Propulsion and Airframe Control) program. The critical steps in IMPAC are exercised on an example integrated flight/propulsion control design for linear airframe/engine models of a conceptual STOVL (Short Take-Off and Vertical Landing) aircraft, and MATRIXX (TM) executive files to implement each step are developed. The results from the example study are analyzed and lessons learned are listed along with recommendations that will improve the application of each design step. The end product of this research is a set of software requirements for developing a user-friendly control design tool which will automate the steps in the IMPAC methodology. Prototypes for a graphical user interface (GUI) are sketched to specify how the tool will interact with the user, and it is recommended to build the tool around existing computer aided control design software packages.
Autonomous Energy Systems
Energy systems are increasingly complicated by the proliferation of clean energy technologies such as solar, wind, storage, electric vehicles, and building automations. Future energy systems will require secure, autonomous, and reliable communications, control, and interoperability among millions of distributed generation points and billions of buildings, vehicles, and more. To enable effective management of the anticipated growth of distributed devices and the deluge of data and extensive metering that will follow, the National Renewable Energy Laboratory (NREL) has developed the concept of autonomous energy systems (AES).
Candidate Structural Materials for In-Core VHTR Application
Graphite moderated gas cooled reactors led the way into the nuclear age with the Chicago Pile-1 reactor, which provided the first sustained critical reaction in December, 1942. The first commercial nuclear plant, Calder Hall in the UK, went critical in 1956 with an outlet gas temperature of {approx}345 C. As depicted in Fig. 1, in five decades since Calder Hall, outlet temperature increased rapidly, reaching a plateau of {approx}950 C. This apparent ceiling is in large part due to limitations in the structural materials utilized within the core (e.g. control systems) and primary loop (hot duct, heat-exchangers etc.) Simply, the operating temperatures of Generation III (HTGR's) are very near performance limits of the structural alloys used, both in terms of elevated temperature and as-irradiated properties. This limitation remains today and is the reason the outlet temperature of the Generation IV Very High Temperature Reactor (VHTR) continues to be revised downward from the original optimistic goal of {approx}1200 C, to it's current target outlet temperature of {approx}950 C, a temperature consistent with the previous generation of HTGR's. An example of the challenges facing Generation IV VHTR is found by considering the control rods. For the Fort St. Vrain Reactor the control system consisted of thirty tubes each containing B4C control material. Alloy 800, originally developed by Inco in the 1950's under the trade-name Incoloy 800 and 800H had found widespread application is steam generators, turbines and was selected for this control rod application. These materials are included for Class 1 Nuclear Component by ASME section III. In addition to Ft. St Vrain, alloy 800H has found control rod application in the German HTR and Japanese HTTR reactors and is the primary choice Pebble Bed Modular Reactor (a HTGR) reactivity control system. Figure 2 gives the ASME allowed stress for Alloy 800H. Due to the loss in creep rupture strength, the allowed design stress for decreases substantially above {approx}500 C. For the operating temperature (and current maximum code temperature) of the Fort St. Vrain reactor ({approx}760 C) the control rod designed from Alloy 800H would be allowed approximately 20 MPa primary stress. For the anticipated temperature of the VHTR that stress would likely be under 10 MPa in the non-irradiated condition. Selection of VHTR in-core structural material will depend on the ability for the material to withstand extreme temperatures and irradiation. The use of Alloy 800H for control rod applications is preferred, but will require designing with a relatively low strength material which becomes brittle upon modest irradiaton. Presently, more fidelity in both design and the available Alloy 800H database are required to judge the lifetime this alloy will have in service. The only currently envisioned alternative to Alloy 800H are the CFC and SiC/SiC composites, which are currently challenged by code qualification issues. As with Alloy 800H, the composite irradiation data-base is inadequate, though it appears that the CFC service lifetime will be limited due to its anisotropic dimensional change under irradiation to doses somewhat higher than Alloy 800H (1-5 x 10{sup 25} n/m{sup 2}), while SiC/SiC composites appear to retain their mechanical properties to doses in excess of the VHTR lifetime dose. As the path to qualification of both CFC and SiC/SiC are similar, it appears that SiC/SiC is more attractive for high-dose Gen IV application unless high thermal conduction is required.
Technology Solutions Case Study: Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate, New Orleans, Louisiana
The purpose of this project by Building Science Corporation was to evaluate the humidity control performance of new single family high performance homes, and compare the interior conditions and mechanical systems operation between two distinct groups of houses: homes with a supplemental dehumidifier installed in addition to HVAC system, and homes without any supplemental dehumidification. The subjects of the study were 10 single-family new construction homes in New Orleans, LA. Data logging equipment was installed at each home in 2012, and interior conditions and various end-use loads were monitored for one year. In terms of averages, the homes with dehumidifiers are limiting elevated levels of humidity in the living space; however, there was significant variation in humidity control between individual houses. An analysis of the equipment operation did not show a clear correlation between energy use and humidity levels. In general, no single explanatory variable appears to provide a consistent understanding of the humidity control in each house. Indoor humidity is likely due to all of the factors we have examined, and the specifics of how they are used by each occupant.
Brilliant Execution of Smart Labs: Employing Best Practices to Improve Safety and Reduce Energy for Sustainable Labs: Preprint
Laboratory buildings often dominate the energy use on research campuses, consuming three to four times the energy of a typical office building. In most cases, these facilities are defined as “mission critical,” with excessive energy use as simply an unfortunate truth that cannot be avoided without compromising safety. However, case studies indicate cost savings opportunities of up to 40% in laboratories (compared to standard practices) by employing energy efficient design strategies that also improve the safety of lab spaces (Better Buildings 2018). To help stakeholders implement improvement measures, the Smart Labs Toolkit describes a proven approach to optimizing performance of laboratories and critical control environments in new or existing facilities. The Toolkit outlines distinct phases for building a successful Smart Labs program that include: Plan, Assess, Optimize, and Manage. Each phase has specific tasks, training videos, and resources to educate users, support the efforts of key stakeholders, and maximize benefits for the organization in implementing high-performance labs. The Toolkit also includes case studies from the 17 Better Buildings Smart Labs Accelerator partners, sharing lessons learned and supporting the Smart Labs approach to safe, efficient world class science. This paper reviews the technology choices for implementing Smart Labs ventilation strategies, controls, and other efficiency measures. Better Building Smart Lab Accelerator partners provide case study examples of safety and energy-savings results of using Smart Labs approaches.
Statistical Analysis of Solar PV Power Frequency Spectrum for Optimal Employment of Building Loads
In this paper, a statistical analysis of the frequency spectrum of solar photovoltaic (PV) power output is conducted. This analysis quantifies the frequency content that can be used for purposes such as developing optimal employment of building loads and distributed energy resources. One year of solar PV power output data was collected and analyzed using one-second resolution to find ideal bounds and levels for the different frequency components. The annual, seasonal, and monthly statistics of the PV frequency content are computed and illustrated in boxplot format. To examine the compatibility of building loads for PV consumption, a spectral analysis of building loads such as Heating, Ventilation and Air-Conditioning (HVAC) units and water heaters was performed. This defined the bandwidth over which these devices can operate. Results show that nearly all of the PV output (about 98%) is contained within frequencies lower than 1 mHz (equivalent to ~15 min), which is compatible for consumption with local building loads such as HVAC units and water heaters. Medium frequencies in the range of ~15 min to ~1 min are likely to be suitable for consumption by fan equipment of variable air volume HVAC systems that have time constants in the range of few seconds to few minutes. This study indicates that most of the PV generation can be consumed by building loads with the help of proper control strategies, thereby reducing impact on the grid and the size of storage systems.
Final Report for Transmission of Information by Acoustic Communication along Metal Pathways in Nuclear Facilities
Transmission of information using elastic waves on existing metallic pipes provides an alternative communication option for a nuclear facility. The advantages of this approach consist of transmitting information through barriers, such as the containment building wall. A viable candidate for acoustic communication channel is a chemical volume control system (CVCS) stainless steel pipe, which penetrates through the containment building wall. A laboratory bench-scale system consisting of a nuclear grade CVCS-like pipe and ultrasonic transducers was assembled for a preliminary communication system analysis. Because of low bandwidth and spectral dispersion of ultrasonic transducers, on off keying (OOK) protocol was chosen for data communication. Operation of the acoustic communication during normal and post-accident conditions involves data transmission on the CVCS pipe, which according to literature guidelines, will be at 50°C and 150°C, respectively. Preliminary communication system development was performed using paintbrush PZT transducers capable of continuous operation at temperatures up to 80°C. Next, high-temperature LiNbO 3 acoustic transducers, originally developed for flow metering applications of EBRII reactor at Argonne, were utilized to develop a high-temperature acoustic communication system. A Gaussian pulse shape filter was introduced to suppress ringing and thus reduce inter-symbol interference. This resulted in enhancement of data transmission bitrate. Heating tapes, temperature controllers, and thermal insulation were installed on the laboratory pipe to study acoustic communication at elevated temperature. This included development of custom insertion heating elements for controlling temperature at pipe ends. Demonstrations of communication at high temperature included transmission of images and text files. Main achievements thus far include demonstration of transmission of 90KB image at the bitrate of 10Kbps with bit error rate smaller than 10 -3 across the pipe heated to 50°C and 150°C. Final phase of project development involved investigating strategies for deployment of the ultrasonic communication system in a representative environment. Mechanisms Engineering Test Loop (METL) facility at ANL was chosen as a viable candidate for communication system demonstration. Analysis of piping manifolds at METL has shown that in a typical scenario, ultrasonic signals have to be transmitted over straight and bent piping sections. This report describes preliminary studies on transmission of information with ultrasonic shear waves across bent piping sections. A test article consisting of a stainless steel pipe bent at 90° was developed for laboratory analysis of ultrasonic signal transmission. The bent piping test article developed by welding two straight pipes to an elbow. For consistency, the diameter and wall thickness of the bent pipe is the same as that of the straight pipe utilized in prior studies. COMSOL computer simulations were performed to study ultrasonic refracted shear wave coupling and transmission across bent piping. Preliminary evaluations of ultrasonic shear wave transmission were conducted with piezoelectric (PZT) and LiNbO 3 transducers, with the signals recorded with previously developed LabView interface. Preliminary results have shown significant dispersion of transmitted signals, most likely due to reflections and scattering by piping welds. Signal distortion compensation algorithm based on time reversal modulation (TRM) was initially investigated for transmission through solids, and demonstrated for signals transmitted over the bent pipe. Using TRM, it was shown that communication bitrates of 100Kbps were achievable, in principle.
Tradeoffs in Prameter Values for Optional Performance
Transmission of information using elastic waves on existing metallic pipes provides an alternative communication option for a nuclear facility. The advantages of this approach consist of transmitting information through barriers, such as the containment building wall. A viable candidate for acoustic communication channel is a chemical volume control system (CVCS) stainless steel pipe, which penetrates through the containment building wall. A laboratory bench-scale system consisting of a nuclear grade CVCS-like pipe and ultrasonic transducers was assembled for a preliminary communication system analysis. Because of low bandwidth and spectral dispersion of ultrasonic transducers, on off keying (OOK) protocol was chosen for data communication. Operation of the acoustic communication during normal and post-accident conditions involves data transmission on the CVCS pipe, which according to literature guidelines, will be at 50°C and 150°C, respectively, In general, continuous operation of most commercial ultrasonic transducers above 50°C is challenging because of transducer material incompatibility with high temperature. High-temperature LiNbO 3 acoustic transducers, originally developed for flow metering applications of EBRII reactor at Argonne, were utilized to develop a high-temperature acoustic communication system. A Gaussian pulse shape filter was introduced to suppress ringing and thus reduce inter-symbol interference. This resulted in enhancement of data transmission bitrate. Heating tapes, temperature controllers, and thermal insulation were installed on the laboratory pipe to study acoustic communication at elevated temperature. This included development of custom insertion heating elements for controlling temperature at pipe ends. Demonstrations of communication at high temperature included transmission of images and text files. Main achievements thus far include demonstration of transmission of 90KB image at the bitrate of 10Kbps with bit error rate smaller than 10 -3 across the pipe heated to 50°C and 150⁰C.
Control Strategies to Reduce the Energy Consumption of Central Domestic Hot Water Systems
Domestic hot water (DHW) heating is the second largest energy end use in U.S. buildings, exceeded only by space conditioning. Recirculation systems consisting of a pump and piping loop(s) are commonly used in multifamily buildings to reduce wait time for hot water at faucets; however, constant pumping increases energy consumption by exposing supply and return line piping to continuous heat loss, even during periods when there is no demand for hot water. In this study, ARIES installed and tested two types of recirculation controls in a pair of buildings in order to evaluate their energy savings potential. Demand control, temperature modulation controls, and the simultaneous operation of both were compared to the baseline case of constant recirculation. Additionally, interactive effects between DHW control fuel reductions and space conditioning (heating and cooling) were estimated in order to make more realistic predictions of the payback and financial viability of retrofitting DHW systems with these controls. Results showed that DHW fuel consumption reduced by 7% after implementing the demand control technique, 2% after implementing temperature modulation, and 15% after implementing demand control and temperature modulation techniques simultaneously; recirculation pump runtime was reduced to 14 minutes or less per day. With space heating and cooling interactions included, the estimated annual cost savings were 8%, 1%, and 14% for the respective control techniques. Possible complications in the installation, commissioning and operation of the controls were identified and solutions offered.
Control Strategies to Reduce the Energy Consumption of Central Domestic Hot Water Systems
Domestic hot water (DHW) heating is the second largest energy end use in U.S. buildings, exceeded only by space conditioning. Recirculation systems consisting of a pump and piping loop(s) are commonly used in multifamily buildings to reduce wait time for hot water at faucets; however, constant pumping increases energy consumption by exposing supply and return line piping to continuous heat loss, even during periods when there is no demand for hot water. In this study, ARIES installed and tested two types of recirculation controls in a pair of buildings in order to evaluate their energy savings potential. Demand control, temperature modulation controls, and the simultaneous operation of both were compared to the baseline case of constant recirculation. Additionally, interactive effects between DHW control fuel reductions and space conditioning (heating and cooling) were estimated in order to make more realistic predictions of the payback and financial viability of retrofitting DHW systems with these controls. Results showed that DHW fuel consumption reduced by 7% after implementing the demand control technique, 2% after implementing temperature modulation, and 15% after implementing demand control and temperature modulation techniques simultaneously; recirculation pump runtime was reduced to 14 minutes or less per day. With space heating and cooling interactions included, the estimated annual cost savings were 8%, 1%, and 14% for the respective control techniques. Possible complications in the installation, commissioning and operation of the controls were identified and solutions offered.
Demonstration of improved vehicle fuel efficiency through innovative tire design, materials, and weight reduction technologies
Cooper completed an investigation into new tire technology using a novel approach to develop and demonstrate a new class of fuel efficient tires using innovative materials technology and tire design concepts. The objective of this work was to develop a new class of fuel efficient tires, focused on the “replacement market” that would improve overall passenger vehicle fuel efficiency by 3% while lowering the overall tire weight by 20%. A further goal of this project was to accomplish the objectives while maintaining the traction and wear performance of the control tire. This program was designed to build on what has already been accomplished in the tire industry for rolling resistance based on the knowledge and general principles developed over the past decades. Cooper’s CS4 (Figure #1) premium broadline tire was chosen as the control tire for this program. For Cooper to achieve the goals of this project, the development of multiple technologies was necessary. Six technologies were chosen that are not currently being used in the tire industry at any significant level, but that showed excellent prospects in preliminary research. This development was divided into two phases. Phase I investigated six different technologies as individual components. Phase II then took a holistic approach by combining all the technologies that showed positive results during phase one development.
Dynamic Assurance of Autonomous Systems Through Ground Control Software
Assurance cases have emerged as a way to build trust in complex autonomous systems. Many assurance case justifications for such systems need to be constantly reevaluated based on the current system context and performance. Autonomous systems, especially those deployed in remote environments, often have a ground control system that enables monitoring and remote operations. In this paper, we propose a dynamic assurance framework that aims at connecting the assurance case with the ground control system. We use the ground control system to facilitate dynamic evaluation of quantitative assurance measures that support various justifications in the assurance case. We demonstrate the proposed dynamic assurance framework on the NASA Ames Research Center project Troupe. We use a combination of in-house and external tools to identify the assurance measures, formalize the related requirements, and generate monitors that feed the data to the external ground control system.