Search NASA⌕ Search

SEARCH · Search NASA

Results for “protocol technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

The Stratospheric Aerosol and Gas Experiment (SAGE) IV Pathfinder

As evidenced by quadrennial holding of this symposium and publishing of the Scientific Assessment of Ozone Depletion, the continued monitoring of and reporting on the stratospheric ozone layer is paramount to determining the efficacy of the Montreal Protocol. Measurements from satellites provided data on the initial decline of ozone in the late 1970s and early 1980s that supported the adoption of the Montreal Protocol, with current observations hinting at recovery. Adequate determination of that recovery requires continuous and, in the case of multiple instruments, overlapping data records. However, most current satellite systems are well beyond their expected lifetimes and are large and expensive. A new measurement paradigm is needed to enable cost-effective, sustainable measurements of atmospheric ozone into the coming decades when ozone is expected to recover. The Stratospheric Aerosol and Gas Experiment (SAGE) IV is a solar occultation imager capable of measuring ozone, aerosol, and other trace gas species with the same quality as previous SAGE instruments (including SAGE III/ISS). Taking advantage of recent technological advancements, a single sensorcraft occupies a 6U CubeSat form-factor providing an order of magnitude reduction in cost over traditional missions. SAGE IV is an example of an innovative and affordable mission that can sustain a crucial science measurement well into the future.

Robert Damadeo↗

Use of Cultivation Data from the Algae Testbed Public Private Partnership as Utilized in NREL's Algae State of Technology Assessments

The Algae Testbed Public Private Partnership (ATP3) conducted algal growth experiments over the course of 16 months termed the Unified Field Studies (UFS). These experiments were conducted at 5 different geographic locations in Arizona (ASU), California (CP), Florida (FA), Georgia (GT), and Hawaii (CELL). The UFS sought to evaluate different algal biomass harvesting strategies using identical ponds, media, and operational conditions through all four seasons across different geographic regions to isolate the effects on productivity attributed to locational climate and seasonal variability, overlaid by the differing harvest strategies. Set up as the baseline against which other experiments would build upon, it must be emphasized that as per the stated, approved experimental goals of the ATP3 UFS, no attempts at growth or lipid accumulation optimization were made; rather, the primary focus of the UFS work was to cultivate algal biomass under deliberate, consistent conditions, time periods, and harvesting protocols, to provide public data on year-round outdoor biomass production that could be directly compared between one site and another (with accompanying climate data for each site). Thus the resulting productivity numbers in effect represent a conservative baseline of non-optimized algal growth one may expect at these sites. Also clearly weather can vary dramatically from season to season and from year to year, and even within a given 'season' where an individual season's data was typically based on 4-6 week operating windows. Thus these numbers also only reflect a short snapshot in time, and must be interpreted carefully in projecting what may be expected over many years or decades (for example, a 30-year facility lifetime as evaluated in techno-economic models).

09 BIOMASS FUELS↗

One-dimensional heterocyclic carbene–Au metal–organic frameworks bridging ultra-high vacuum models and scalable liquid-phase growth

The controlled design of molecule–metal interfaces is central to the development of functional nanomaterials for catalysis, sensing, and molecular electronics. Here we show that the adsorption of a Janus-type diimidazolium precursor on gold yields one-dimensional (1D) N-heterocyclic carbene (NHC)–Au–NHC metal organic frameworks (MOFs) featuring positively charged gold nodes. Using synchrotron X-ray photoemission spectroscopy (XPS), near edge X-ray adsorption fine structure (NEXAFS) spectroscopy and scanning tunnelling microscopy (STM), we demonstrate that thermal activation promotes counterion removal and drives the formation of extended 1D arrays, characterized by ∼1.0 nm Au–Au spacing and adatom densities up to 0.6 atom nm −2 (∼4% of surface atoms). Importantly, we translate this ultra-high vacuum (UHV) benchmark into a scalable solution-phase protocol in ethanol, enabling 1D-MOF growth under mild, base-free, open-air conditions. The resulting films retain structural and electronic signatures of UHV-grown systems, bridging model studies and practical synthesis. This approach establishes NHC–metal frameworks as accessible, tunable platforms for catalysis and materials design.

Gold adatoms↗

Traceable random numbers from a non-local quantum advantage

The unpredictability of random numbers is fundamental to both digital security and applications that fairly distribute resources. However, existing random number generators have limitations—the generation processes cannot be fully traced, audited and certified to be unpredictable. The algorithmic steps used in pseudorandom number generators are auditable, but they cannot guarantee that their outputs were a priori unpredictable given knowledge of the initial seed. Device-independent quantum random number generators can ensure that the source of randomness was unknown beforehand, but the steps used to extract the randomness are vulnerable to tampering. Here we demonstrate a fully traceable random number generation protocol based on device-independent techniques. Our protocol extracts randomness from unpredictable non-local quantum correlations, and uses distributed intertwined hash chains to cryptographically trace and verify the extraction process. This protocol forms the basis for a public traceable and certifiable quantum randomness beacon that we have launched. Over the first 40 days of operation, we completed the protocol 7,434 out of 7,454 attempts—a success rate of 99.7%. Each time the protocol succeeded, the beacon emitted a pulse of 512 bits of traceable randomness. The bits are certified to be uniform with error multiplied by actual success probability bounded by 2−64. Further, the generation of certifiable and traceable randomness represents a public service that operates with an entanglement-derived advantage over comparable classical approaches.

97 MATHEMATICS AND COMPUTING↗

Air kerma based dosimetry calibration for the Leksell Gamma Knife

No accepted official protocol exists for the dosimetry of the Leksell Gamma Knife registered (GK) stereotactic radiosurgery device. Establishment of a dosimetry protocol has been complicated by the unique partial-hemisphere arrangement of 201 individual {sup 60}Co beams simultaneously focused on the treatment volume and by the rigid geometry of the GK unit itself. This article proposes an air kerma based dosimetry protocol using either an in-air or in-acrylic phantom measurement to determine the absorbed dose rate of fields of the 18 mm helmet of a GK unit. A small-volume air ionization chamber was used to make measurements at the physical isocenter of three GK units. The absorbed dose rate to water was determined using a modified version of the AAPM Task Group 21 protocol designed for use with {sup 60}Co-based teletherapy machines. This experimentally determined absorbed dose rate was compared to the treatment planning system (TPS) absorbed dose rate. The TPS used with the GK unit is Leksell GammaPlan. The TPS absorbed dose rate at the time of treatment is the absorbed dose rate determined by the physicist at the time of machine commissioning decay corrected to the treatment date. The TPS absorbed dose rate is defined as absorbed dose rate to water at the isocenter of a water phantom with a radius of 8 cm. Measurements were performed on model B and C Gamma Knife units. The absorbed dose rate to water for the 18 mm helmet determined using air-kerma based calculations is consistently between 1.5% and 2.9% higher than the absorbed dose rate provided by the TPS. These air kerma based measurements allow GK dosimetry to be performed with an established dosimetry protocol and without complications arising from the use of and possible variations in solid phantom material. Measurements were also made with the same ionization chamber in a spherical acrylic phantom for comparison. This methodology will allow further development of calibration methods appropriate for the smaller fields of GK units to be compared to a well established standard.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

"Soiling, Cleaning, and Abrasion: The Results of the Five-Year Photovoltaic Glass Coating Field Study" [Slides]

External contamination ("soiling") of the incident surface is a major limiting factor for solar technologies. A 5-year field glass coupon study was conducted to better understand external contamination and its effects; compare cleaning methods and the use of preventative coatings; and explore the abrasion resulting from cleaning to advise on accelerated abrasion testing. Test sites included the cities of Dubai (UAE), Kuwait City (Kuwait), Mesa (AZ), Mumbai (India), and Sacramento (CA). Through the 5-year cumulative study, dry brush, water spray, and wet sponge and squeegee cleaning methods were compared to no cleaning. Optical microscopy was used to obtain images, including representative color images, grayscale images for object analysis, and oblique images for coating integrity assessment. A thresholding protocol was developed to analyze and distinguish specimens using the ImageJ software. Optical performance was quantified using a spectrophotometer, including comprehensive optical characterization (transmittance, reflectance, and absorptance in addition to forward- and back-scattering). Atomic force microscopy was used to verify the abrasion damage morphology, including the width and depth of surface scratches. Analysis of the results included correlation of optical performance and particle area coverage, rank order (by coating or location), and the acceleration factor for abrasion damage. The efficacy of external cleaning was more readily distinguished from the effectiveness of antisoiling coatings. The acceleration factor for dry brush cleaning of a porous silica coating was found to be on the order of unity.

14 SOLAR ENERGY↗

Update on NASA's Laser Communications Relay Demonstration Project

This paper provides an update on NASA's Laser Communications Relay Demonstration Project (LCRD), a joint project between NASA's Goddard Space Flight Center (GSFC), the Jet Propulsion Laboratory, California Institute of Technology (JPL), and the Massachusetts Institute of Technology Lincoln Laboratory (MIT/LL). LCRD will provide a minimum of two years of high data rate optical communications services to demonstrate a concept of operations for future mission critical Earth relay satellites. LCRD is expected to launch in June 2019 and demonstrate how optical communications can meet NASA's growing need for higher data rates, or for the same data rate provided by a comparable RF system, how it enables lower power, lower mass communications systems on user spacecraft. In addition, LCRD's architecture will allow it to serve as a testbed in space for the development of additional symbol coding, link and network layer protocols, etc. LCRD's mission and architecture has slowly evolved since the project first started and this paper will provide an update of LCRD and planned capabilities and experiments.

Optical Communications↗

Global Arrays Parallel Programming Toolkit

The two predominant classes of programming models for parallel computing are distributed memory and shared memory. Both shared memory and distributed memory models have advantages and shortcomings. Shared memory model is much easier to use but it ignores data locality/placement. Given the hierarchical nature of the memory subsystems in modern computers this characteristic can have a negative impact on performance and scalability. Careful code restructuring to increase data reuse and replacing fine grain load/stores with block access to shared data can address the problem and yield performance for shared memory that is competitive with message-passing. However, this performance comes at the cost of compromising the ease of use that the shared memory model advertises. Distributed memory models, such as message-passing or one-sided communication, offer performance and scalability but they are difficult to program. The Global Arrays toolkit attempts to offer the best features of both models. It implements a shared-memory programming model in which data locality is managed by the programmer. This management is achieved by calls to functions that transfer data between a global address space (a distributed array) and local storage. In this respect, the GA model has similarities to the distributed shared-memory models that provide an explicit acquire/release protocol. However, the GA model acknowledges that remote data is slower to access than local data and allows data locality to be specified by the programmer and hence managed. GA is related to the global address space languages such as UPC, Titanium, and, to a lesser extent, Co-Array Fortran. In addition, by providing a set of data-parallel operations, GA is also related to data-parallel languages such as HPF, ZPL, and Data Parallel C. However, the Global Array programming model is implemented as a library that works with most languages used for technical computing and does not rely on compiler technology for achieving parallel efficiency. It also supports a combination of task- and data-parallelism and is available as an extension of the message passing (MPI) model. The GA model exposes to the programmer the hierarchical memory of modern high-performance computer systems, and by recognizing the communication overhead for remote data transfer, it promotes data reuse and locality of reference. Virtually all the scalable architectures possess non-uniform memory access characteristics that reflect their multi-level memory hierarchies. These hierarchies typically comprise processor registers, multiple levels of cache, local memory, and remote memory. Over time, both the number of levels and the cost (in processor cycles) of accessing deeper levels has been increasing. It is important for any scalable programming model to address memory hierarchy since it is critical to the efficient execution of scalable applications.

ARMCI↗

To automate or not to automate : this is the question.

New protocols and instrumentation significantly boost the outcome of structural biology, which has resulted in significant growth in the number of deposited Protein Data Bank structures. However, even an enormous increase of the productivity of a single step of the structure determination process may not significantly shorten the time between clone and deposition or publication. For example, in a medium size laboratory equipped with the LabDB and HKL-3000 systems, we show that automation of some (and integration of all) steps of the X-ray structure determination pathway is critical for laboratory productivity. Moreover, we show that the lag period after which the impact of a technology change is observed is longer than expected.

59 BASIC BIOLOGICAL SCIENCES↗

Initial approaches in benchmarking and round robin testing for proton exchange membrane water electrolyzers

As ever increasing amounts of renewable electricity enter the energy supply mix on a regional, national and international basis, greater emphasis is being placed on energy conversion and storage technologies to deal with the oscillations, excess and lack of electricity. Hydrogen generation via proton exchange membrane water electrolysis (PEMWE) is one technology that offers a pathway to store large amounts of electricity in the form of hydrogen. The challenges to widespread adoption of PEMWE lie in their high capital and operating costs which both need to be reduced through R&D. An evaluation of reported performance data in literature for PEMWE reveals that there are excessive variations of in situ performance results that make it difficult to draw conclusions on the pathway forward to performance optimization and future R&D directions. In order to enable the meaningful comparison of in-situ performance evaluation across laboratories there is an obvious need for standardization of materials and testing protocols. Herein, we address this need by reporting the results of a round robin test effort conducted at the laboratories of five contributors to the IEA electrolysis annex 30. The effort utilized common sets of test articles, materials, test cells, and employed a set of shared test protocols. The maximum observed deviation between laboratories at 1 A cm-2 at cell temperatures of 60 and 80 degrees C, was 27 and 20 mV, respectively. The deviation of the results from laboratory to laboratory was a factor of 2-3 higher than the lowest deviation observed at one single lab and test station. However, the highest deviations observed were 1/10th of those extracted by a literature survey on similar material sets. The biggest takeaways are that cell temperature control appears to be the most significant source of deviation between results, while care must be taken with respect to break in conditions and cell electrical connections for meaningful performance data.

08 HYDROGEN↗

Low Cost Open-Path Instrument for Monitoring Atmospheric Carbon Dioxide at Sequestration Sites

In the past 48 months of the project, we have accomplished all objectives outlined in the proposal. In the first year, we demonstrated the technology for remote sensing on a bench top scale. The core electronics are designed and fabricated. We achieved results that will safely deliver the specifications outlined in the proposal. In the 2nd year, 2 major technical tasks outlined in the Statement of Objectives, i.e. Build a field test ready prototype of a long-range CO2 monitor, and characterize its performance in the short term and demonstrate that the monitor characteristics meet the goals set in the initial proposal, have been accomplished. We also conducted simulation work that defines the different deployment strategies for our sensors at sequestration sites. In the 3rd year, Specifications and Testing protocols have been developed for the CO2 monitor. 1% accuracy had been demonstrated in short period tests ({approx}1 hour). Unattended system operation and stability over a period of a week has been demonstrated with and without EDFA (laser power amplifier). The sensitivity of the instrument to CO2 leaks has been demonstrated. In the 4th no-cost extension year, we further field tested the system and the experience we accumulated give us a clear picture of what else are needed for final field deployment. These results have shown all the objectives of the project have been fulfilled. In July 2008, along with our commercial partner we won the DOE STTR phase I award to commercialize the instrument developed in this project - a testimony to the achievement of this research.

47 OTHER INSTRUMENTATION↗

On Representative Spaceflight Instrument and Associated Instrument Sensor Web Framework

Sensor Web-based adaptation and sharing of space flight mission resources, including those of the Space-Ground and Control-User communication segment, could greatly benefit from utilization of heritage Internet Protocols and devices applied for Spaceflight (SpaceIP). This had been successfully demonstrated by a few recent spaceflight experiments. However, while terrestrial applications of Internet protocols are well developed and understood (mostly due to billions of dollars in investments by the military and industry), the spaceflight application of Internet protocols is still in its infancy. Progress in the developments of SpaceIP-enabled instrument components will largely determine the SpaceIP utilization of those investments and acceptance in years to come. Likewise SpaceIP, the development of commercial real-time and instrument colocated computational resources, data compression and storage, can be enabled on-board a spacecraft and, in turn, support a powerful application to Sensor Web-based design of a spaceflight instrument. Sensor Web-enabled reconfiguration and adaptation of structures for hardware resources and information systems will commence application of Field Programmable Arrays (FPGA) and other aerospace programmable logic devices for what this technology was intended. These are a few obvious potential benefits of Sensor Web technologies for spaceflight applications. However, they are still waiting to be explored. This is because there is a need for a new approach to spaceflight instrumentation in order to make these mature sensor web technologies applicable for spaceflight. In this paper we present an approach in developing related and enabling spaceflight instrument-level technologies based on the new concept of a representative spaceflight Instrument Sensor Web (ISW).

Kizhner, Semion↗

Adaptive nonequilibrium design of actin-based metamaterials: Fundamental and practical limits of control

The adaptive and surprising emergent properties of biological materials self-assembled in far-from-equilibrium environments serve as an inspiration for efforts to design nanomaterials. In particular, controlling the conditions of self-assembly can modulate material properties, but there is no systematic understanding of either how to parameterize external control or how controllable a given material can be. Here, we demonstrate that branched actin networks can be encoded with metamaterial properties by dynamically controlling the applied force under which they grow and that the protocols can be selected using multi-task reinforcement learning. These actin networks have tunable responses over a large dynamic range depending on the chosen external protocol, providing a pathway to encoding “memory” within these structures. Interestingly, we obtain a bound that relates the dissipation rate and the rate of “encoding” that gives insight into the constraints on control—both physical and information theoretical. Taken together, these results emphasize the utility and necessity of nonequilibrium control for designing self-assembled nanostructures.

59 BASIC BIOLOGICAL SCIENCES↗

Lieb-Mattis States for Robust Entangled Differential Phase Sensing

We explore a two-node, entanglement-enhanced sensor network for differential phase sensing that exploits decoherence-free subspaces to suppress common-mode noise, a primary limitation of many state-of-the-art quantum sensors. We identify a class of entangled states that, while not strictly optimal, achieve the same asymptotic sensitivity scaling as optimal states and can be prepared efficiently from initially unentangled atomic ensembles. Importantly, the preparation time decreases with increasing system size, which makes the states compatible with realistic noise processes in present-day quantum sensors that operate with large particle numbers but lack full error correction. We illustrate these ideas using two cavity-mediated preparation protocols: (i) coherent, unitary entanglement generation analogous to bosonic two-mode squeezing, yielding Heisenberg scaling, and (ii) dissipative preparation through collective emission into a shared cavity mode, providing a square-root improvement beyond the standard quantum limit. Numerical simulations show that both approaches remain effective at experimentally realistic cavity cooperativities, establishing a practical path toward scalable, quantum-enhanced differential phase sensing.

Kaubruegger, Raphael [National Institute of Standa↗

Initial experience with a SiPM-based PET/CT scanner: influence of acquisition time on image quality

Background: A newly introduced PET/CT scanner (Discovery Meaningful Insights—DMI, GE Healthcare) includes the silicon photomultiplier (SiPM) with timeof-flight (TOF) technology first used in the GE SIGNA PET/MRI. In this study, we investigated the impact of various acquisition times on image quality using this SiPM-based PET/CT. Methods: We reviewed data from 58 participants with cancer who were scanned using the DMI PET/CT scanner. The administered dosages ranged 295.3–429.9 MBq (mean ± SD 356.3 ± 37.4) and imaging started at 71–142 min (mean ± SD 101.41 ± 17. 52) after administration of the radiopharmaceutical. The patients’ BMI ranged 19.79–46. 16 (mean ± SD 26.55 ± 5.53). We retrospectively reconstructed the raw TOF data at 30, 60, 90, and 120 s/bed and at the standard image acquisition time per clinical protocol (180 or 210 s/bed depending on BMI). Each reconstruction was reviewed blindly by two nuclear medicine physicians and scored 1–5 (1—poor, 5—excellent quality). The liver signal-to-noise ratio (SNR) was used as a quantitative measure of image quality. Results: The average scores ± SD of the readers were 2.61 ± 0.83, 3.70 ± 0.92, 4.36 ± 0.82, 4.82 ± 0.39, and 4.91 ± 0.91 for the 30, 60, 90, and 120 s/bed and at standard acquisition time, respectively. Inter-reader agreement on image quality assessment was good, with a weighted kappa of 0.80 (95% CI 0.72–0.81). In the evaluation of the effects of time per bed acquisition on semi-quantitative measurements, we found that the only time point significantly different from the standard time were 30 and 60 s (both with P < 0.001). The effects of dose and BMI were not statistically significant (P = 0.195 and 0.098, respectively). There was a significant positive effect of time on SNR (P < 0.001), as well as a significant negative effect of weight (P < 0.001). Conclusions: Our results suggest that despite significant delays from injection to imaging (due to comparison with standard PET/CT) compared to standard clinical operations and even in a population with average BMI > 25, images can be acquired as fast as 90 s/bed using the SiPM PET/CT and still result in very good image quality (average score > 4).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Identification and Evaluation for Fueling of NRIC DOME Reactors Report

The National Reactor Innovation Center (NRIC) has designed a testbed for advanced microreactor experiments that enables and encourages technology developers to bring advanced designs closer to commercial availability. The test bed, Demonstration of Microreactor Experiments (DOME), will be used to facilitate much of the operation experimentation process of the each advanced microreactor including fueling and operational power experiments. This report identifies and evaluates the options for initial fueling the microreactors in DOME. This report also discusses the optional locations that were considered for the initial fueling of microreactor; namely the Transient Reactor Test (TREAT) reactor building, and an unspecified temporary location. But various logistical and construction issues essentially eliminated these other options from further consideration. A brief discussion in this report outlines potential equipment and protocol associated with fueling in DOME.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Monitoring cognitive function and need with the automated neuropsychological assessment metrics in Decompression Sickness (DCS) research

Hypobaric decompression sickness (DCS) research presents the medical monitor with the difficult task of assessing the onset and progression of DCS largely on the basis of subjective symptoms. Even with the introduction of precordial Doppler ultrasound techniques for the detection of venous gas emboli (VGE), correct prediction of DCS can be made only about 65 percent of the time according to data from the Armstrong Laboratory's (AL's) hypobaric DCS database. An AL research protocol concerned with exercise and its effects on denitrogenation efficiency includes implementation of a performance assessment test battery to evaluate cognitive functioning during a 4-h simulated 30,000 ft (9144 m) exposure. Information gained from such a test battery may assist the medical monitor in identifying early signs of DCS and subtle neurologic dysfunction related to cases of asymptomatic, but advanced, DCS. This presentation concerns the selection and integration of a test battery and the timely graphic display of subject test results for the principal investigator and medical monitor. A subset of the Automated Neuropsychological Assessment Metrics (ANAM) developed through the Office of Military Performance Assessment Technology (OMPAT) was selected. The ANAM software provides a library of simple tests designed for precise measurement of processing efficiency in a variety of cognitive domains. For our application and time constraints, two tests requiring high levels of cognitive processing and memory were chosen along with one test requiring fine psychomotor performance. Accuracy, speed, and processing throughout variables as well as RMS error were collected. An automated mood survey provided 'state' information on six scales including anger, happiness, fear, depression, activity, and fatigue. An integrated and interactive LOTUS 1-2-3 macro was developed to import and display past and present task performance and mood-change information.

Nesthus, Thomas E.↗