Search NASA⌕ Search

SEARCH · Search NASA

Results for “AIR INLET”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Effect of exhaust gas recirculation on emissions from a flame-tube combustor using Liquid Jet A fuel

The effects of uncooled exhaust gas recirculation as an inert diluent on emissions of oxides of nitrogen (NO + NO2) and on combustion efficiency were investigated. Ratios of recirculated combustion products to inlet airflow were varied from 10 to 80 percent by using an inlet air ejector nozzle. Liquid Jet A fuel was used. The flame-tube combustor was 10.2 cm in diameter. It was operated with and without a flameholder present. The combustor pressure was maintained constant at 0.5 MPa. The equivalence ratio was varied from 0.3 to 1.0. The inlet air temperature was varied from 590 to 800 K, and the reference velocity from 10 to 30 m/sec. Increasing the percent recirculation from 10 to 25 had the following effects: (1) the peak NOx emission was decreased by 37 percent, from 8 to 5 g NO2/kg fuel, at an inlet air temperature of 590 K and a reference velocity of 15 m/sec; (2) the combustion efficiency was increased, particularly at the higher equivalence ratios; and (3) for a high combustion efficiency of greater than 99.5 percent, the range of operation of the combustor was nearly doubled in terms of equivalence ratio. Increasing the recirculation from 25 to 50 percent did not change the emissions significantly.

Marek, C. J.↗

Knock-Limited Performance of Triptane and Xylidines Blended with 28-R Aviation Fuel at High Compression Ratios and Maximum-Economy Spark Setting

An investigation was conducted to evaluate the possibilities of utilizing the high-performance characteristics of triptane and xylidines blended with 28-R fuel in order to increase fuel economy by the use of high compression ratios and maximum-economy spark setting. Full-scale single-cylinder knock tests were run with 20 deg B.T.C. and maximum-economy spark settings at compression ratios of 6.9, 8.0, and 10.0, and with two inlet-air temperatures. The fuels tested consisted of triptane, four triptane and one xylidines blend with 28-R, and 28-R fuel alone. Indicated specific fuel consumption at lean mixtures was decreased approximately 17 percent at a compression ratio of 10.0 and maximum-economy spark setting, as compared to that obtained with a compression ratio of 6.9 and normal spark setting. When compression ratio was increased from 6.9 to 10.0 at an inlet-air temperature of 150 F, normal spark setting, and a fuel-air ratio of 0.065, 55-percent triptane was required with 28-R fuel to maintain the knock-limited brake power level obtained with 28-R fuel at a compression ratio of 6.9. Brake specific fuel consumption was decreased 17.5 percent at a compression ratio of 10.0 relative to that obtained at a compression ratio of 6.9. Approximately similar results were noted at an inlet-air temperature of 250 F. For concentrations up through at least 20 percent, triptane can be more efficiently used at normal than at maximum-economy spark setting to maintain a constant knock-limited power output over the range of compression ratios tested.

Held, Louis F.↗

Experimental evaluation of two premixing-prevaporizing fuel injection concepts for a gas turbine catalytic combustor

A premixing-prevaporizing fuel system to be used with a catalytic combustor was evaluated for possible application in an automotive gas turbine. Spatial fuel distribution and degree of vaporization were measured using jet A fuel. Two types of air blast injectors were tested, a splash groove injector and a multiple jet cross stream injector. Air swirlers with vane angles of 15 deg and 30 deg were used to improve the spatial fuel distribution in a 12 cm diameter tubular rig. Distribution and vaporization measurements were made 35.5 cm downstream of the injector. The spatial fuel distribution was nearly uniform with the multiple jet contrastream injector and the splash-groove injector with a 30 deg air swirler. The vaporization was nearly 100 percent at an inlet air temperature of 600 K, and at 800 K inlet air temperature fuel oxidation reactions were observed. The total pressure loss was less than 0.5 percent of the total pressure for the multiple jet cross stream injector and the splash groove injector (without air swirler) and less than 1 percent for the splash groove with a 30 deg air swirler.

Tacina, R.↗

Effect of primary-zone water injection on pollutants from a combustor burning liquid ASTM A-1 and vaporized propane fuels

A combustor segment 0.457 meter (18 in.) long with a maximum cross section of 0.153 by 0.305 meter (6 by 12 in.) was operated at inlet-air temperatures of 590 and 700 K, inlet-air pressures of 4 and 10 atmospheres, and fuel-air ratios of 0.014 and 0.018 to determine the effect of primary-zone water injection on pollutants from burning either propane or ASTM A-1 fuel. At a simulated takeoff condition of 10 atmospheres and 700 K, multiple-orifice nozzles used to inject water at 1 percent of the airflow rate reduced nitrogen oxides 75 percent with propane and 65 percent with ASTM A-1 fuel. Although carbon monoxide and unburned hydrocarbons increased with water injection, they remained relatively low; and smoke numbers were well below the visibility limit.

Ingebo, R. D.↗

Effect of water injection on nitric oxide emissions of a gas turbine combustor burning natural gas fuel

The effect of direct water injection on the exhaust gas emissions of a turbojet combustor burning natural gas fuel was investigated. The results are compared with the results from similar tests using ASTM Jet-A fuel. Increasing water injection decreased the emissions of oxides of nitrogen (NOX) and increased the emissions of carbon monoxide and unburned hydrocarbons. The greatest percentage decrease in NOX with increasing water injection was at the lowest inlet-air temperature tested. The effect of increasing inlet-air temperature was to decrease the effect of the water injection. The reduction in NOX due to water injection was almost identical to the results obtained with Jet-A fuel. However, the emission indices of unburned hydrocarbons, carbon monoxide, and percentage nitric oxide in NOX were not.

Marchionna, N. R.↗

Emission Characteristics of an Axially Staged Sector Combustor for a Small Core High OPR Subsonic Aircraft Engine

This paper presents the nitrogen oxides, carbon monoxide, and particulate matter emissions of a single sector axially staged combustor sector designed and fabricated by United Technologies Research Center (UTRC) in partnership with NASA under a compact low-emissions combustor contract supported by the NASA Advanced Air Transport Technology (AATT) N+3 project. The test was conducted at NASA Glenn Research Center's CE-5 combustion test facility. The facility provided inlet air temperatures up to 922 K and pressures up to 19.0 bar. The combustor design concept, called Axially Controlled Stoichiometry (ACS), was developed by Pratt & Whitney (P&W) under NASA's Environmentally Responsible Aviation (ERA) program for an N+2 combustor for use in twin-aisle subsonic aircraft engines. Under the N+3 project the ACS combustor was scaled-down for application to small-core N+3 engines for use in single-aisle aircraft. The results show that the NOx and CO emissions characteristics are similar in both the N+2 and N+3 applications. The non-volatile particulate matter (nvPM) emissions trends are similar to CO emissions with an exception at high fuel-air ratio, as inlet air temperature and pressure conditions change from taxi to approach. Three NOx correlation equations are generated to describe theNOx emissions of this combustor. The percentage landing and takeoff (LTO) NOx reduction of the N+3 ACS combustor is between 82% and 89% relative to the ICAO CAEP/6 standard, which meets the NASA N+3 goal of exceeding 80% LTO NOx reduction.

He, Zhuohui J.↗

High-pressure combustor exhaust emissions with improved air-atomizing and conventional pressure-atomizing fuel nozzles

A high-pressure combustor segment 0.456 meter (18 in.) long with a maximum cross section of 0.153 by 0.305 meter (6 by 12 in.) was tested with specially designed air-atomizing and conventional pressure-atomizing fuel nozzles at inlet-air temperatures of 340 to 755 k (610 deg to 1360 R), reference velocities of 12.4 to 26.1 meters per second (41 to 86 ft/sec), and fuel-air ratios of 0.008 to 0.020. Increasing inlet-air pressure from 4 to 20 atmospheres generally increased smoke number and nitric oxide, but decreased carbon monoxide and unburned hydrocarbon concentrations with air-atomizing and pressure-atomizing nozzles. Emission indexes for carbon monoxide and unburned hydrocarbons were lower at 4, 10, and 20 atmospheres, and nitric oxide emission indexes were lower at 10 and 20 atmospheres with air-atomizing than with pressure-atomizing nozzles.

Ingebo, R. D.↗

Exploratory Investigation of Aerodynamic Flameholders for Afterburner Application

An investigation was conducted to determine the flameholding capabilities of aerodynamic jets at afterburner operating conditions. Stability data for a number of aerodynamic flameholders were obtained in a 5- by 5-inch test section at inlet-air reference velocities up to 600 feet per second, an inlet-air temperature of 1250 F, and a combustor-inlet pressure of 15 inches of mercury absolute. Combustion efficiency and stability data of the more promising combinations were then obtained in a 10- by 12-inch test section at the same test conditions. Both air and stoichiometric mixtures of fuel and air were used in the jets; mixture flow rates were approximately 1 percent by weight of the total air-flow rate. Injection pressures were limited to values that might be available from compressor-bleed air. At a reference velocity of 600 feet per second, aerodynamic flame-holders alone were unable to maintain a stable flame at injection pressures up to 70 pounds per square inches large reductions in velocity were required to achieve flame stabilization. When the aerodynamic jets were used in combination with a V-gutter flameholder with approximately a 30 percent blocked area, flame stabilization was attained at a velocity of 600 feet per second; however, the combustion efficiencies of the various combinations were no greater than that obtained with the V-gutter alone.

Butze, Helmut F.↗

Development of Wing Inlets

Lift, drag, internal flow, and pressure distribution measurements were made on a low-drag airfoil incorporating various air inlet designs. Two leading-edge air inlets are developed which feature higher lift coefficients and critical Mach than the basic airfoil. Higher lift coefficients and critical speeds are obtained for leading half of these inlet sections but because of high suction pressures near exist, slightly lower critical speeds are obtained for the entire inlet section than the basic airfoil.

AIRFOILS - DOUGLAS G-17 - CHAR , MOMENTS & ORDINAT↗

Effects of flameholder blockage on emissions and performance of lean premixed-prevaporized combustors

Results from a parametric study are presented. Tests were on conducted at inlet air pressure of 300,000 and 500,000 pascals, inlet air temperatures of 600K, 700K and 800K, reference velocites from 20 to 35 meters per second, and equivalent ratios from the lean stability limit to 0.7 using Jet A fuel. The tests were conducted in a closed duct test facility. Results from the test support the theory that flameholder blockage is one of the major determinants of the size and shape of the recirculation zone. The test data show that higher blockage with its larger recirculation zone provides more residence time which leads to more NOx formation.

Duerr, R. A.↗

Effect of degree of fuel vaporization on emissions for a premixed-prevaporized combustor system

The impact of the degree of fuel vaporization upon emission from a flametube combustor was studied using an inlet air pressure of 3 x 10 to the 5th power pascals, inlet air temperatures of 600K and 700K, a reference velocity of 35 meters per second and equivalence ratios of .6 and .72 using Jet A fuel. Incoming air was preheated to temperatures from 600K to 700K by a nonvitiating preheater. Jet A fuel was injected into this airstream through two different fuel injectors manifolded together and mounted in series upstream of a watercooled preforated plate flameholder. The fuel-air mixture burned in a watercooled combustor section. Samples of the fuel-air mixture upstream of the flameholder were obtained for analysis to determine the local degree of fuel vaporization and the fuel-air ratio. Samples of the combustion products were analyzed to determine gaseous emissions. The effects of vaporization on carbon monoxide and nitric on carbon monoxide and nitric oxide emissions are presented.

Cooper, L. P.↗

Comparison of Non-Combusting Spray Fields in a Model Combustor using Shadowgraphy

Droplet sizes were measured using shadowgraphy in the spray issuing from the center element of the baseline configuration of the NASA 7-element lean direct injector (LDI) array. Each LDI element consisted of a 60 degree clockwise axial air swirler, converging-diverging venturi, and a pressure-swirl atomizer positioned with its tip at the venturi throat. The non-combusting measurements were conducted using water spray in a 3-inch diameter research combustor operating at pressure of 5 bar and air inlet temperature of 700 K. At these inlet conditions, three air flow rates were used, producing reference velocities of 7.6, 15.2, and 22.9 m/s. Only the center nozzle was used. At each reference velocity, water flow rates were adjusted to simulate a common equivalence. Data were collected at a frame rate of 15 Hz over a range of positions near the LDI dump plane, and downstream, along the combustor centerline. Velocity measurements were achieved by use of a dual head Nd:YAG laser and frame transfer PIV camera. Droplet size and velocity, mass and number density, and volume fraction are compared at these inlet conditions to determine the effect of nozzle pressure drop on the measured properties.

lean direct injection↗

Comparison of Non-Combusting Spray Fields in a Model Combustor using Shadowgraphy

Droplet sizes were measured using shadowgraphy in the spray issuing from the center element of the baseline configuration of the NASA 7-element lean direct injector (LDI) array. Each LDI element consisted of a 60 degree clockwise axial air swirler, converging-diverging venturi, and a pressure-swirl atomizer positioned with its tip at the venturi throat. The non-combusting measurements were conducted using water spray in a 3-inch diameter research combustor operating at pressure of 5 bar and air inlet temperature of 700 K. At these inlet conditions, three air flow rates were used, producing reference velocities of 7.6, 15.2, and 22.9 m/s. Only the center nozzle was used. At each reference velocity, water flow rates were adjusted to simulate a common equivalence. Data were collected at a frame rate of 15 Hz over a range of positions near the LDI dump plane, and downstream, along the combustor centerline. Velocity measurements were achieved by use of a dual head Nd:YAG laser and frame transfer PIV camera. Droplet size and velocity, mass and number density, and volume fraction are compared at these inlet conditions to determine the effect of nozzle pressure drop on the measured properties.

lean direct injection↗

Experimental evaluation of premixing-prevaporizing fuel injection concepts for a gas turbine catalytic combustor

Experiments were performed to evolve and evaluate a premixing-prevaporizing fuel system to be used with a catalytic combustor for possible application in an automotive gas turbine. Spatial fuel distribution and degree of vaporization were measured using Jet A fuel. Three types of air blast injectors, an air assist nozzle and a simplex pressure atomizer were tested. Air swirlers with vane angles up to 30 deg were used to improve the spatial fuel distribution. The work was done in a 12-cm (4.75-in.) diameter tubular rig. Test conditions were: a pressure of 0.3 and 0.5 MPa (3 and 5 atm), inlet air temperatures up to 800 K (980 F), velocity of 20 m/sec (66 ft/sec) and fuel-air ratios of 0.01 and 0.025. Uniform spatial fuel distributions that were within plus or minus 10 percent of the mean were obtained. Complete vaporization of the fuel was achieved with air blast configurations at inlet air temperatures of 550 K (530 F) and higher. The total pressure loss was less than 0.5 percent for configurations without air swirlers and less than 1 percent for configurations with a 30 deg vane angle air swirler.

Tacina, R. R.↗

Performance of a single fuel-vaporizing combustor with six injectors adapted for gaseous hydrogen

The combustor was operated over a range of inlet-air pressures from 5.3 to 24.0 inches of mercury absolute and inlet-air reference velocities from 60 to 100 feet per second. The combustion efficiencies obtained with the six configurations varied from about 65 to 95 percent for a combustor temperature-rise range of 200 degrees to 1400 degrees F. At a temperature rise of 1200 degrees F (near-rated engine conditions), the spread in efficiencies of the six configurations was about 5 percent. Efficiencies in the range of 65 to 85 percent were obtained at operating conditions beyond the burning range of conventional jet fuels. A fuel-injector configuration that fed only gaseous hydrogen fuel into the standard liquid-fuel-vaporizing tubes generally gave the highest efficiencies. This configuration minimizes the possibility of combustion in the fuel-vaporizing tubes and could be easily adapted to the full-scale engine combustor.

Wear, Jerrold D↗

Regenerable Liquid Desiccants for High Efficiency Humidity Control in Microgravity

The NASA X-Hab project aims to design, manufacture, test, and prove functionality of an air humidity control subsystem to dehumidify and re-humidify air from a space cabin. The method of regulating cabin air humidity utilizes vortex phase separation, which uses an ionic liquid (IL) desiccant for air-water phase separation. This subsystem is intended to be integrated with a CO 2 removal system requiring de-humidified air to operate efficiently. The air humidity control subsystem is composed of a cold-desiccant or cold-side Vortex Phase Separator (VPS) that dehumidifies the cabin air. The dehumidified air exits the cold-side (CS) VPS chamber to flow into the CO 2 removal module, and the cold, water-laden liquid desiccant flows to a regenerative heat exchanger. From the heat exchanger the liquid desiccant continues to the heater. After heating, the desiccant flows into a hot-desiccant or hot-side (HS) VPS as the dehumidified air from CO 2 removal module enters through the HS VPS air inlet. The rehumidified air exits the HS VPS into the space cabin. One pump installed at the liquid exit of the CS VPS and one pump installed at the liquid exit of the HS VPS transport the fluid through the system. To evaluate the system’s efficiency and effectiveness, the temperature, pressure, flow rate and relative humidity are read, recorded, and analyzed at critical points along the module.

Gerardo Castro↗

Performance and emission characteristics of swirl-can combustors to near-stoichiometric fuel-air ratio

Emissions and performance characteristics were determined for two full annular swirl-can combustors operated to near stoichiometric fuel-air ratio. Test condition variations were as follows: combustor inlet-air temperatures, 589, 756, 839, and 894 K; reference velocities, 24 to 37 meters per second; inlet pressure, 62 newtons per square centimeter; and fuel-air ratios, 0.015 to 0.065. The combustor average exit temperature and combustor efficiency were calculated from the combustor exhaust gas composition. For fuel-air ratios greater than 0.04, the combustion efficiency decreased with increasing fuel-air ratios in a near-linear manner. Increasing the combustor inlet air temperature tended to offset this decrease. Maximum oxides of nitrogen emission indices occurred at intermediate fuel-air ratios and were dependent on combustor design. Carbon monoxide levels were extremely high and were the primary cause of poor combustion efficiency at the higher fuel-air ratios. Unburned hydrocarbons were low for all test conditions. For high fuel-air ratios SAE smoke numbers greater than 25 were produced, except at the highest inlet-air temperatures.

Diehl, L. A.↗

Pressure control valve

A control valve is provided which is adapted to be connected between a pressure source, such as a vacuum pump, and a pressure vessel so as to control the pressure in the vessel. The valve comprises a housing having a longitudinal bore which is connected between the pump and vessel, and a transversely movable valve body which controls the air flow through an air inlet in the housing. The valve body includes cylindrical and conical shaped portions which cooperate with reciprocally shaped portions of the housing to provide flow control. A filter in the air inlet removes foreign matter from the air. The bottom end of the valve body is screwed into the valve housing control knob formed integrally with the valve body and controls translation of the valve body, and the opening and closing of the valve.

Lambson, K. H.↗