At least 145 records · Page 8

An algorithmic approach to predicting mechanical draft cooling tower fan speeds from infrasound signals

Mechanical draft cooling towers (MDCTs) serve a critical heat management role in a variety of industries. For nuclear reactors in particular, the consistent, predictable operation of MDCTs is required to avoid damage to infrastructure and reduce the potential for catastrophic failure. Accurate, reliable measurement of MDCT fan speed is therefore an important maintenance and safety requirement. To that end, we have developed an algorithm for automatically predicting the rotational speeds of multiple, simultaneously operating fan rotors using contactless, infrasound measurements. The algorithm is based on identifying the blade passing frequencies (BPFs), their harmonics, as well as the motor frequencies (MFs) for each fan in operation. Using the algorithm, these frequencies can be automatically identified in the acoustic waveform’s short-time Fourier transform spectrogram. Attribution is aided by a set of filters that rely on the unique spectral and temporal characteristics of fan operation, as well as the intrinsic frequency ratios of the BPF harmonics and the BPF/MF signals. The algorithm was tested against infrasound data acquired from infrasound sensors deployed at two research reactors: the Advanced Test Reactor (ATR) located at Idaho National Laboratory (INL) and the High Flux Isotope Reactor (HFIR) located at Oak Ridge National Laboratory (ORNL). After manually identifying the MDCT gearbox ratio, the algorithm was able to quickly yield fan speeds at both reactors in good agreement with ground truth. Ultimately, this work demonstrates the ease by which MDCT fans may be monitored in order to optimize operational conditions and avoid infrastructure damage.

42 ENGINEERING↗

Analysis of Radiological Release From Fueled Irradiation Experiments During Manual Handling (Slides)

Irradiation experiments are manually handled at the Advanced Test Reactor (ATR) by qualified operators using long handled tools. Standard handling evolutions include insertion and removal from the reactor vessel, transfer to/from a storage location or cask in the ATR canal, and handling/reconfigurations at a canal working tray. Such routine handling has the potential to result in mechanical damage to the experiment boundary which is credited to retain fission products. Since damage can occur due to operator error, this is an anticipated occurrence. This work determines the radiological consequences to receptors inside the ATR facility, as well as public receptors. Given the wide variety of fuel types tested at the ATR, a generic approach to the analysis is taken. The radiological inventory is determined to bound a variety of fuel types (e.g., ceramic and molten fuel matrices) and fission powers on the U-235 enrichment spectrum. The source term analysis considers different release fractions to bound different fuel types and burnups. The postulated handling events occur underwater; thus, retention of the released isotopic content is considered within the canal water column. Retention of radionuclides in the water column is determined using a modified approach of United States (US) Nuclear Regulatory Commission (NRC) Regulatory Guide (RG) 1.183. Radiological dose to the facility receptor is determined using a compartment release model. Dose to the public receptor is determined using atmospheric dispersion models using site specific atmospheric conditions with the use of the Radiological Safety Analysis Computer (RSAC) program version 7.2.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Modernization of the Radiation Measurements Laboratory at the Advanced Test Reactor Complex

The Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) is a unique, water-cooled, high-flux test reactor capable of performing tests prototypical of PWR operating conditions. The Radiation Measurements Laboratory (RML) was founded in the 1960s to support reactor operations and to conduct independent scientific research. For nearly six decades RML has performed four primary functions: monitoring of radioactivity by gamma-ray spectroscopy of routine reactor samples, fluence rate determinations for irradiation cycles, fission-rate measurements for the ATR-Critical (ATR-C) Facility, and independent research and development of radiation detection systems and applications. Through the decades, RML has seen technological advancements that have been integrated into each of the critical functions of the laboratory. However, many of the measurement and analysis systems employed to this day can be improved by modernization. Recent progess at RML are improving reliability and accuracy of the radiation measurements performed in support of nuclear energy research for the U.S.A. Department of Energy. The control and data collection systems supporting ATR-C have been upgraded. New High-Purity Germanium (HPGe) spectrometers have been procured with liquid nitrogen recycling capabilities to improve up-time and reduce measurement uncertainties. Fluence-rate measurement techniques are also being improved to ensure accuracy, avoid systemic errors, and identify biases. In a parallel effort, new scientific research avenues are being explored which will provide an opportunity to further enhance the utilization of ATR and ensure the sustainability of the RML as nuclear research continues to evolve. The RML is improving the effectiveness of irradiation services provided by ATR while ensuring a sustainable future for nuclear energy research.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modernization of the Radiation Measurements Laboratory at the Advanced Test Reactor Complex

The Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) is a unique, water-cooled, high-flux test reactor capable of performing tests prototypical of PWR operating conditions. The Radiation Measurements Laboratory (RML) was founded in the 1960s to support reactor operations and to conduct independent scientific research. For nearly six decades RML has performed four primary functions: monitoring of radioactivity by gamma-ray spectroscopy of routine reactor samples, fluence rate determinations for irradiation cycles, fission-rate measurements for the ATR-Critical (ATR-C) Facility, and independent research and development of radiation detection systems and applications. Through the decades, RML has seen technological advancements that have been integrated into each of the critical functions of the laboratory. However, many of the measurement and analysis systems employed to this day can be improved by modernization. Recent progress at RML is improving reliability and accuracy of the radiation measurements performed in support of nuclear energy research for the U.S.A. Department of Energy. The control and data collection systems supporting ATR-C have been upgraded. New High-Purity Germanium (HPGe) spectrometers have been procured with liquid nitrogen recycling capabilities to improve up-time and reduce measurement uncertainties. Fluence-rate measurement techniques are also being improved to ensure accuracy, avoid systemic errors, and identify biases. In a parallel effort, new scientific research avenues are being explored which will provide an opportunity to further enhance the utilization of ATR and ensure the sustainability of the RML as nuclear research continues to evolve. The RML is improving the effectiveness of irradiation services provided by ATR while ensuring a sustainable future for nuclear energy research.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Reducing Uncertainty in Hydrodynamic Modeling of ATR Experiments Via Flow Testing, Validation, and Optimization

The development, characterization, and qualification testing of nuclear fuel at Idaho National Laboratory’s Advanced Test Reactor (ATR) requires extensive design and analysis activities prior to the insertion of an irradiation experiment in-pile. Significant effort is made in the design and development phase of all in-pile experiments to ensure that the maximum feasible impacts of all necessary experimental requirements are satisfied. The advancement of fuel, cladding, and in-reactor materials technology in recent years has introduced complexities associated with the design and construct of in-pile experiments necessitating deeper understanding of boundary conditions and increasingly comprehensive observations resulting from the experiment. Each unique experiment must be assessed for neutronics response, thermal/hydraulic/hydrodynamic performance, and structural integrity. This is accomplished either analytically, computationally, or experimentally, or some combination thereof, prior to insertion into the ATR. The various effects are interrelated to various degrees, such as the case with the experiment temperature affecting the thermal cross section of the fuel or the increased temperature of the experiment’s materials reducing the mechanical strength of the assemblies. Additionally, the feedback between the experiment’s response to a reactor transient could alter the neutron flux profile of the reactor during the transient. Each experiment must therefore undergo a barrage of analyses to assure the ATR operational safety review committee that the insertion and irradiation of the experiment will not detrimentally affect the safe operational envelope of the reactor. In many cases, the nuclear fuel being tested can be double-encapsulated to ensure safety margins are adequately addressed, whereas failed fuel would be encased in a protective capsule. In other cases, the experiments can be inserted in a self-contained loop that passes through the reactor core, remaining isolated from the primary coolant. In the case of research reactor fuel, however, the fuel plates must be tested in direct contact with the reactor coolant, and being fuel designed for high neutron fluxes, they are inherently power-dense plates. The combination of plate geometry, high-power density, and direct contact with primary coolant creates a scenario where the neutronic/thermomechanic/hydrodynamic characteristics of the fuel plates are tightly coupled, necessitating as complete characterization as possible to support the safety and programmatic assessments, thus enabling a successful experiment. This paper explores the efforts of the U.S. High-Performance Research Reactor program to thermomechanically/hydromechanically characterize the program’s wide variety of experiments, which range from stacks of miniplate capsules to full-sized, geometrically representative curved plates. Special attention is given to instances where the combination of experimental characterization and analytical assessment has reduced uncertainties of the safety margins, allowing experiments to be irradiated that would otherwise not have passed the rigorous qualification process for irradiation in the ATR. In some cases, the combined processes have exposed flow and heat transfer characteristics that would have been missed using historical methods, which allows for more accurate and representative postirradiation assessments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Retractable Sensors for In-Core Use in Material Test Reactors - conf paper

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 - 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on friction drive wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 - 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology's MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Retractable Sensors for In-Core Service in Material Test Reactors

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 - 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on counter-rotating wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 - 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology's MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Retractable Sensors for In-Core Service in Material Test Reactors

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 – 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on counter-rotating wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 – 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology’s MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Dosimetry for the Boise State University JW 15-8242 Irradiation in ATR (Rev.1)

PNNL project 79550 provides for the analysis of neutron fluence monitors irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory in accordance with MPO 00269673and Statement of Work No. 19704, Rev. 0, PNNL Analysis of NSUF Flux Capsules. This report is for the Boise State University (BSU) JW 15-8242 irradiations which were conducted in positions A6, A7 and A8 of the ATR. We previously reported data for this experiment after about 1 dpa in a report issued in January 2021 (1). This report is for longer irradiations to about 3 dpa. Other experiments included in the statement of work for this project will be reported separately. The neutron fluence monitors were prepared by PNNL and loaded into the BSU assemblies prior to irradiation. Following irradiation, the capsules were returned to PNNL for analysis. The neutron dosimetry capsules were opened, the flux wires were removed for gamma or x-ray analysis, and the measured activities were used to determine the activation rates for various activation products. Following suitable corrections, the measured activation rates were used to adjust calculated neutron spectra at each fluence monitor location. The adjusted neutron spectra were then used to determine displacement per atom (dpa) and gas production for irradiated materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

IMPACT-01 Assembly Overview [Slides]

The Irradiated Material Properties Accelerated Characterization Test (IMPACT) series of experiments will irradiate three metallic fuel alloy specimens with embedded thermal conductivity probes in the Advanced Test Reactor (ATR). Metallic fuel alloys have long been under investigation for use in advanced reactors on account of their high thermal conductivity. Metallic fuel undergoes dramatic microstructural changes early in life due to fission gas swelling until ~2-3 at% burnup when pores interconnect, thus allowing fission gas to escape into the fuel pin plenum and swelling effectively ceases. The evolution of metallic fuel thermal conductivity during this early phase has never been successfully measured in situ. This experiment will be designed to use advances in measurement sciences to characterize how thermal transport properties evolve while in reactor. The IMPACT experiment consists of three metallic fuel rodlets with thermal conductivity probes axially centered within the fuel specimen. This presentation is an overview of the IMPACT-01 assembly process with a focus MFC fuel fabrication and experiment assembly steps.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron Dosimetry for the GE Hitachi 16-10393 Irradiation in ATR

PNNL project 74242 involves the analysis of neutron fluence monitors and melt wires irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory in accordance with MPO 00236287 and Statement of Work (SOW) No. 17370, Rev. 0, PNNL Analysis of NSUF Flux and Melt Wire Capsules. This report is for the GE Hitachi 16-10393 irradiation which was conducted in positions B11 of the ATR. Three other irradiations included in the SOW will be reported separately. The neutron fluence monitors were prepared by PNNL and loaded into the GE Hitachi assemblies prior to irradiation. Following irradiation, the capsules were returned to PNNL for analysis. The neutron dosimetry capsules were opened, the flux wires were removed for gamma analysis. The measured activities were used to determine the activation rates for various activation products. Following suitable corrections, the measured activation rates were used to adjust calculated neutron spectra at each fluence monitor location. The adjusted neutron spectra were then used to determine displacement per atom (dpa) and gas production for irradiated materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Melt Wire Analyses for the Colorado School of Mines (CSM 16-10584) Irradiation in ATR

PNNL project 74242 involves the analysis of neutron fluence monitors and melt wires irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory in accordance with MPO 00236287 and Statement of Work No. 17370, Rev. 0, PNNL Analysis of NSUF Flux and Melt Wire Capsules. This report is for the Colorado School of Mines (CSM 16-10584) experiment which was conducted in position B5 of the ATR. Neutron fluence monitor results were reported in February 2021 in report Neutron Dosimetry for the Colorado School of Mines (CM 16-10584) Irradiation in ATR. This report presents the analyses of the melt wire capsules that were included along with the neutron fluence monitors. Each capsule was identified by the ID stamp on the bottom, then opened to assess the condition of the Pb and Zn-Al wires as well as the Bi powder. Pictures are included to illustrate the results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modeling Summary of ASNF in DOE Sealed Standard Canisters

A pathway for road-ready and final disposition packaging configurations for the aluminum-clad spent nuclear fuel (ANSF) fuel dictates storage within helium backfilled sealed DOE standard canisters. The typical packaging configuration for the 15-foot DOE canisters places 10 advance test reactor (ATR) elements within a Type 1a basket, and three baskets are loaded within each DOE canister. During in-reactor operations and cooling pond storage conditions, oxyhydroxide layers form on the surface of the aluminum clad fuel. These layers produce hydrogen gas over time due to the fuel’s radiation field. As part of the packing procedure, the ATR fuel should be dried to remove any residual physio-/chemi- sorbed water bound to the surface. The results of this modeling will include results at fully saturated and fully dried conditions. In addition, fuels that are currently stored at the Savannah River Site were also studied for their potential for hydrogen and pressure build up. These two additional fuels modeled were the Missouri University Research Reactor (MURR) fuel, which is packaged in the same configuration as the ATR, but with a 10-foot-tall DOE standard canister. This was selected due to its relatively high decay heat compared to other DOE-managed ASNF. The second additional fuel studied with the modeling effort was the High Flux Isotope Reactor (HFIR) fuel. This fuel is modeled as two separate DOE canisters with the inner and outer annulus split for storage. The HFIR was selected for study due to its high aluminum cladding surface area. In the associated experimental work, Task 2 - Oxyhydroxide Layer Radiolytic Gas Generation Resolution, additional tests were completed in a helium environment, and updated G-values for the radiolytic production of hydrogen from the oxyhydroxide layers were provided. These values were 2.92 ×10 -4 µmol/J at 50% relative humidity and 4.12 ×10 -4 µmol/J at 100% relative humidity. These values are lower than the value for Argon that was used in prior modeling results. In addition, prior modeling results have been completed with the G-value applied to just the mass of the corrosion layer, and this has been updated to apply the G-value for hydrogen generation to the full mass of the fuel. These two effects combine to show much smaller pressure and hydrogen build up for the sealed canister model. For a nominal scenario of stored ATR fuel, after 50 years the model results give a 1.36 atm total pressure, 7% mole percent hydrogen, for the upper decay heat, 1.51 atm total pressure, 16% mole percent hydrogen, and for upper decay heat with undried fuel 2.6 atm total pressure, 15% mole percent hydrogen. For the MURR nominal case, the model results give 1.34 atm and 6% hydrogen, for upper decay heat this gives 1.41 atm total pressure with 10.8 % hydrogen, and for upper decay heat with undried fuel, this gives 2.38 atm total pressure with 9.9% hydrogen. The nominal scenario for HFIR fuel gives 1.39 atm total pressure with 9.9% hydrogen, the upper decay heat case gives 1.43 atm with 12.1% hydrogen, and the upper decay heat with undried fuel gives 2.17 atm total pressure with 11.9% hydrogen. These results confirm the ATR scenario bounds the other intact ASNF modeled here. No case modeled yields significant oxygen, and the lower decay heat cases for all fuels modeled have hydrogen concentrations that are under the 4% flammability limit after 50 years of storage. In addition, the modeled pressures for all cases are all significantly below the 500-psi limit for the DOE standard sealed canister.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Enhancing Post-Irradiation Examination (PIE) Efficiency with High-Throughput Experiments

Nuclear materials testing is essential for understanding changes in reactor environments, but traditional methods are costly and time-consuming. High-Throughput Experimentation (HTE) enables rapid screening and optimization of material properties by significantly increasing the number of specimens in the experiment. In this work, HTE methods were employed to irradiate novel materials at the Advanced Test Reactor (ATR) at Idaho National Laboratory. A total of 367 sub-sized tensile specimens were irradiated using the standard capsule design. To facilitate HTE, automated systems such as the Automated Mechanical Testing System were implemented for mechanical testing within hot cell environments, thereby reducing the need for manual interaction with hot cell manipulators and significantly lowering both the cost and duration of experiments. Digital image correlation (DIC) was used to measure displacement during mechanical testing, providing precise, non-contact measurement capabilities. The methodologies developed in this research will support the advancement of HTE techniques for future nuclear materials testing experiments at ATR. This approach allows for more efficient and cost-effective evaluation of new materials, ultimately leading to improved reactor performance, enhanced safety, and extended longevity within the nuclear industry.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

First Annual Progress Report on the Procurement and Post-Irradiation Examination of the Selected Samples of Alloy 800H and Grade 92 and 91 Steels

Ferritic-martensitic steel Grade 92, with Grade 91 as a reference, together with austenitic stainless steel (or Incoloy Alloy) 800H and its grain-boundary-engineered version 800H-TMP (Thermo-Mechanical Processing), is investigated in this project. A total of fifteen Grade 92 samples from two or three heats, four T91 samples from two heats, and six 800H and six 800H-TMP samples from one heat were selected, which were primarily irradiated in the Advanced Test Reactor (ATR) of Idaho National Laboratory (INL), with the rest in the High Flux Isotope Reactor (HFIR) of Oak Ridge National Laboratory (ORNL), BOR-60 of Russia, and Phénix reactor of France. The samples were irradiated in the temperature range of 241 to 720°C and a dose range of 1.28 to ~70 displacements per atom. All the INL and ORNL samples and part of the LANL (Los Alamos National Laboratory) samples have been received at the Irradiated Materials Examination and Testing (IMET) hot cell facility. The selected ORNL samples include six Grade 92 and two 800H samples, which were irradiated in the HFIR to 0.46–14.66 dpa at 400 to ~720°C. The Grade 92 is an optimized heat and named as G92-2b. The two 800H samples have one sample as the standard solution-annealed condition and the other sample as a TMP condition with a maximized fraction of low-Σ coincidence site lattice (CSL) boundaries. Tensile test of the G92-2b samples were conducted at room temperature in the IMET hot cell. The lower temperature irradiation at 400–496.7°C to 0.52–14.66 dpa resulted in minimal changes in tensile properties. However, the higher temperature irradiation at ~683.3–720°C to 0.46–14.63 dpa tended to reduce yield and tensile strength by about –136 to –311 MPa and plastic elongation by –1 to –3% with the increasing dose. The 800H and 800H-TMP samples were tensile-tested at their irradiation temperature 580°C in the IMET hot cell, which showed >40% increase in yield and tensile strength with nearly 9% reduction in elongation for 800H-TMP compared with 800H. Three of the G92-2b samples, i.e., GB04 (7.44 dpa at ~490°C), GB05 (14.66 dpa at 496.7°C), and GB12 (14.63 dpa at ~720°C), were examined at the LAMDA for Vickers hardness measurements and microstructural characterization by SEM and TEM. Vickers hardness was successfully measured on GB12, which was reduced by is – (112.4 ± 12.3) HV1 from the control sample. However, the Vickers hardness measurements were failed on GB04 and GB05 because the samples were polished too thin to prevent the interference from the substrate (epoxy). The other half of the GB04 and GB05 will be polished for the hardness measurements, as well as nanoindentation studies. Fractography by SEM indicated increased numbers of ductile dimples (or voids) with the increasing irradiation dose, while significantly increased numbers and sizes of dimples with the increasing irradiation temperature. TEM characterization exhibited the presence of Cr 23 C 6 , VN, and Laves precipitates at boundaries and matrix, which showed pronounced precipitate-dislocation interactions (pinning effect). Dense dislocations but limited dislocation loops were observed in the samples, which noticeably reduced in GB12. Additionally, some tiny partially amorphized spherical domains were observed in GB12, which had a normal body-centered cubic lattice parameter of 9Cr steels at the surround regions but ~11% smaller than the lattice parameter of the matrix away from the amorphized spherical domains. Further characterization will be pursued to clarify the new findings.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

As-Run ATR Physics Evaluation for the UCF-1 HSIS Experiment

This Engineering Calculations and Analysis Report (ECAR) documents the Advanced Test Reactor (ATR) detailed MCNP full core model physics analysis performed to support the irradiation of the University of Central Florida (UCF-1) Hydraulic Shuttle Irradiation System Experiment in the ATR B-7 position. The purpose of this analysis is to calculate: • The as-run neutron and gamma heating rates for the experiment components (W/g); • The as-run DPA for the experiment specimens after 20 (test train 1) and 2 (test train 2) days of irradiation in the ATR B-7 position (neutrons/cm2-sec); • The radionuclide source term after 2 days and 20 days of irradiation in the ATR B-7 position; • The decay heat associated with the UCF-1 radionuclide source term. These calculations were performed using the computer codes MCNP and ORIGEN2. The neutronics model, analysis details, and results are presented in the attached report.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ATR Firewater Pump Replacement

The objective of this project is to replace two faulty firewater pumps at INL's Advanced Test Reactor (ATR). Around ATR, firewater pumps can serve from one to all three of these functions: emergency core injection, emergency canal makeup, and firefighting. Both pumps serve firefighting functions but one also serves the function of emergency canal makeup, a nuclear function, so it is required to go through nuclear grade dedication. Both pumps are currently in the process of being procured.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Refining Absorber Shroud Geometry to Maximize Power Output and Reduce Power Peaking in ATF Test Train

In the wake of the Fukushima Daiichi nuclear power plant accident in 2011, the accident tolerant fuels (ATF) program was initiated to enhance the safety of light-water reactor fuels, placing significant emphasis on cladding. A crucial step for the broad implementation of ATF in commercial reactors involves irradiation testing of the fuel designs. ATF-2D, the latest experiment in the ATF series, is slated to undergo irradiation in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). ATF-2D is a joint effort of the INL with industry partners General Electric Global Research; Framatome; General Atomics; the Japan Atomic Energy Agency; Hitachi-GE Nuclear Energy, Ltd; Global Nuclear Fuel-Japan Co., Ltd; Nippon Nuclear Fuel Development Co., Ltd; and Mitsubishi Heavy Industries, Ltd. The ATF-2D test train design consists of four tiers, each housing six rodlets. The device will be inserted in Loop 2A within the central flux trap of the ATR, and is anticipated to undergo irradiation throughout three 60-day cycles. Typical pressurized water reactor conditions will be emulated during the irradiation. The objective of the work presented here is to dimension neutron-absorbing hafnium (Hf) components surrounding the fuel rodlets, such that the axial power profile is flattened, while simultaneously ensuring that the total fission power output of the entire test train remains below 200 kW.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗