Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerator Design Technology, and Operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Electron Activity (Secondary Electron & Field Emission ) Suppression by Magnetic Field Placed on the Surface of Metals And Dielectric [Slides]

Secondary electron emission happens when the surface is exposed to an oscillating electromagnetic field. It has extremely dangerous effect when resonance condition of this oscillating field and higher SEY conditions are met. The dependence of the secondary electron on primary electron energy is shown in the figure. This multiplication effect on the number of electrons in oscillating electromagnetic field is called multipacting. The problem with multipacting exist in many scientific fields like LHC, ISS, ITER involving particle accelerator, space science and fusion research. In high intensity proton rings this multiplies electron get trapped inside the potential created by proton beam called electron cloud. In High power microwave sources, rf couplers and rf window to couple the power also hugely affected by multipacting.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Northstar Accelerator Based Mo99 Production Facility Design Support

Facility design support in FY20 centered on transfer of the target insertion and design details to MBraun and Springs, the companies under contract via Northstar to do the hot cell, target insertion and the local target shielding. A significant number of changes have been introduced by these vendors which have been reviewed and critiqued. In addition, the company contracted to produce the Mo100 disks announced that the tolerance on the thickness of 0.5 mm would be ±25%. An alternative design of the target holder was proposed. Bulk shielding and local target shielding design work has continued also and will be reported. Ongoing design and cooling issues continue to arise as the facility takes shape and moves toward completion. LANL is part of the team identifying, analyzing and designing solutions to these issues. Many of these are covered in this report.

43 PARTICLE ACCELERATORS↗

Enhanced Beam Diagnostics with Existing BPPMs via GPU-powered Multi-Particle Simulation

This research aims to utilize the multi-particle code, High-Performance Simulator (HPSim), to realistically model the Side-Coupled-Cavity Linac (CCL) lattice of the LANSCE accelerator. This new model would allow us to predict the beam’s bunch length (the longitudinal spread), which is unavailable for individual accelerating modules or only accessible at the end of the linac. However, a correct bunch length is critical for the high-energy beam transport after the CCL. Its impact would be most significant in the Proton Storage Ring (PSR), where we should be able to reduce losses for the circulating beam. The PSR is scheduled to have a 25% current increase for the neutron spallation target upgrade at the Lujan Center. A highly bunched beam would be necessary to reduce the particle losses and lower the radiation levels produced from the ring. A realistic HPSim model with >1M macro-particles can help tackle the beam losses at the sub-percent level. This new work would also create a realistic surrogate model for future machine learning projects.

43 PARTICLE ACCELERATORS↗

Northstar Mo99 Window Tests

Tests were completed for window to “first disk” (actually a steel plate for these expariments) gaps of 20 mil as per design gap as well as 10 mil and 30 mil gaps to span the range of possible variations. With possible disk distortion in beam, another test with 0 gap was performed. Based on deflections measured during the pressure test, the 0 gap was most likely very near 3 mil.

43 PARTICLE ACCELERATORS↗

New accelerator capabilities with the high-gradient C-band [Slides]

LANSCE accelerator upgrades: Applications such as pRad desire higher proton beam energy. Material science at LANL will benefit from powerful directional high repetition rate X-ray sources. As it considers itself to be the NNSA accelerator laboratory, LANL should play role in developing compact accelerators for various national security missions.

43 PARTICLE ACCELERATORS↗

Beam Coupling Impedances of Inter-cell Section in Scorpius Linac

The following technical note is prepared for distribution to external project collaborators. An inter-cell pumping section in the Scorpius linac contains a pumping grid with slots, bellows, and vacuum plenum. The beam coupling impedances of the inter-cell section are calculated with CST Studio. Important to note that all impedance values in the tech note below should be divided by a factor of 2 to obtain the beam coupling impedances in their standard definition; see reference for details.

43 PARTICLE ACCELERATORS↗

Mo-100 Disk Structural Integrity Tests I

The NorthStar pressed and sintered 29 mm diameter, 0.5 mm thick Mo-100 disks will be subjected to large temperature gradients when in beam during production. The beam preferentially heats the disk center, while the aggressive cooling by the helium keeps areas outside the beam spot relatively cool. The result is a temperature gradient of up to 900°C over the radial distance of 14.5 mm. To test the disk integrity with this high temperature gradient, a special holder for a single disk was made such that proper cooling can be applied as in the design target and the disk heating can be replicated with induction heating. NorthStar press and sintered disks were used for these tests.

36 MATERIALS SCIENCE↗

LANL Report on Northstar Facility Design Support FY21

As Northstar enters a stage of rapid progress in the construction and implementation of their accelerator based Mo99 production facility, LANL has been supporting the effort as requested. This support is often an assistance response to issues as they arise. This report will describe these issues and the LANL contribution in analysis, advice and experimentation.

43 PARTICLE ACCELERATORS↗

LANL Report on Northstar Facility Design Support FY2021

As Northstar enters a stage of rapid progress in the construction and implementation of their accelerator based Mo99 production facility, LANL has been supporting the effort as requested. This support is often an assistance response to issues as they arise. This report will describe these issues and the LANL contribution in analysis, advice and experimentation.

43 PARTICLE ACCELERATORS↗

NorthStar Helium Cooling System. Final Report on LANL Contribution

From the beginning of NNSA support to the NorthStar development of a production facility for the medical isotope Molybdenum-99 (Mo99), LANL has been responsible for the design and testing of a target and its cooling. The target is comprised of a stack of Mo100 disks separated by coolant flow gaps between the disks and between the first disk and a housing window, which separates the target and its coolant from the vacuum of the beam line. The target, and therefore its cooling requirements, evolved steadily over the years of system development

07 ISOTOPE AND RADIATION SOURCES↗

Niowave Flow Testing of the High Power Converter - FY 21

Design work for a 100 kW converter to produce a neutron flux via electron impact on a flowing stream of liquid metal lead-bismuth (LBE) was conducted in FY20. In FY21, the focus shifted to a 20 kW converter which was designed in collaboration with Niowave engineers. A flow visualization model is needed to validate model results for the 20 kW converter and ensure adequate coolant flow over containment structures. This work highlights the mockup that was made with quartz side plates by LANL.

42 ENGINEERING↗

High Brightness High Duty Factor Negative Ion Beam Injector [Slides]

The high brightness negative ion injector combines multiple individual low-duty-factor H- ion sources (multiplexing) in a manner that allows flexibility in final pulse format and beam duty factor up to CW and increases reliability by eliminating an otherwise single-point failure usually associated with using a single ion source. The multiplexing of multiple beams in new injector system also preserves the beam quality of each individual ion source, eliminating a significant source of beam quality degradation usually associated with combining beams.

43 PARTICLE ACCELERATORS↗

Evaluation of Synthetic Diamond Detectors for Fast Neutron and X-ray Detection [Slides]

Element6 has come out of a two year production pause (pre-COVID) with material that lacks their previous QC – some is excellent, but screening is needed. Applied Diamond can now make usable polycrystalline material, for applications not requiring absolute flux calibration. A large area possible (1cm 2 ). Great Lakes Crystal Technology has made great progress in two years, but still needs development to become a trusted supplier of single crystal material. LANL staff (Dongsung Kim) has developed proficient lithography and bonding expertise at CINT to make devices from vendor supplied material. LANL staff has continued and expanded capabilities for device testing at NSLS-II.

42 ENGINEERING↗