Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAMS, RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Characterization of Electronic Materials HgZnSe and HgZnTe Using Innovative and Conventional Techniques

HgZnSe and HgZnTe are electronic materials of interest for potential IR detector and focal plane array applications due to their improved strength and compositional stability over HgCdTe, but they are difficult to grow on Earth and to fully characterize. Conventional contact methods of characterization, such as Hall and van der Paw, although adequate for many situations are typically labor intensive and not entirely suitable where only very small samples are available. To adequately characterize and compare properties of electronic materials grown in low earth orbit with those grown on Earth, innovative techniques are needed that complement existing methods. This paper describes the implementation and test results of a unique non-contact method of characterizing uniformity, mobility, and carrier concentration together with results from conventional methods applied to HgZnSe and HgZnTe. The innovative method has advantages over conventional contact methods since it circumvents problems of possible contamination from alloying electrical contacts to a sample and also has the capability to map a sample. Non- destructive mapping, the determination of the carrier concentration and mobility at each place on a sample, provides a means to quantitatively compare, at high spatial resolution, effects of microgravity on electronic properties and uniformity of electronic materials grown in low-Earth orbit with Earth grown materials. The mapping technique described here uses a 1mm diameter polarized beam of radiation to probe the sample. Activation of a magnetic field, in which the sample is placed, causes the plane of polarization of the probe beam to rotate. This Faraday rotation is a function of the free carrier concentration and the band parameters of the material. Maps of carrier concentration, mobility, and transmission generated from measurements of the Faraday rotation angles over the temperature range from 300K to 77K will be presented. New information on band parameters, obtained by combining results from conventional Hall measurements of the free carrier concentration with Faraday rotation measurements, will also be presented. One example of how this type of information was derived is illustrated in the following figure which shows Faraday rotation vs wavelength modeled for Hg(l-x)ZnxSe at a temperature of 300K and x=0.07. The plasma contribution, total Faraday rotation, and interband contribution to the Faraday rotation, are designated in the Figure as del(p), FR tot, and del(i) respectively. Experimentally measured values of FR tot, each indicated by + , agree acceptably well with the model at the probe wavelength of 10.6 microns. The model shows that at the probe wavelength, practically all the rotation is due to the plasma component, which can be expressed as delta(sub p)= 2pi(e(sup 3))NBL/c(sup 2)nm*(sup 2) omega(sup 2). In this equation, delta(sub p) is the rotation angle due to the free carrier plasma, N is the free carrier concentration, B the magnetic field strength, L the thickness of the sample, n the index of refraction, omega the probe radiation frequency, c the speed of light, e the electron charge, and m* the effective mass. A measurement of N by conventional techniques, combined with a measurement of the Faraday rotation angle allows m* to be accurately determined since it is an inverse square function.

Tanton, George↗

Total-dose radiation effects data for semiconductor devices, volume 2

Total ionizing dose radiation test data on integrated circuits are analyzed. Tests were performed with the electron accelerator (Dynamitron) that provides a steady state 2.5 MeV electron beam. Some radiation exposures were made with a Cobalt-60 gamma ray source. The results obtained with the Cobalt-60 source are considered an approximate measure of the radiation damage that would be incurred by an equivalent dose of electrons.

Price, W. E.↗

Whistler-mode radiation from the Spacelab 2 electron beam

During the Spacelab 2 mission the Plasma Diagnostics Package (PDP) performed a fly-around of the Shuttle at distances of up to 300 meters while an electron beam was being ejected from the Shuttle. A magnetic conjunction of the Shuttle and the PDP while the electron gun was operating in a steady (DC) mode is discussed. During this conjunction, the PDP detected a clear funnel-shaped emission that is believed to be caused by whistler-mode emission from the beam. Ray-path calculations show that the shape of the funnel can be accounted for by whistler-mode waves propagating near the resonance cone. Because the beam and waves are propagating in the same direction, the radiation must be produced by a Landau interaction with the beam. Other types of waves generated by the beam are also described.

Gurnett, D. A.↗

Resistive anode image converter

The invention of an apparatus for imaging soft X-ray and ultraviolet electromagnetic radiation and charged particles was described. The apparatus includes a pair of microchannel electron multiplier plates connected in a cascaded chevron configuration which intercepts an incident beam of radiation or charged particles. Incident photons or charged particles strike the front surface of the chevron configuration causing emission of electrons. The electrons are accelerated by a voltage gradient and strike the inner side walls of the individual channels, causing emission of secondary electrons. Accelerated and multiplied secondary electrons impinge upon a resistive anode after they transverse the chevron configuration. A pulse position circuit converts the magnitude or transit time of the currents flowing from the point of impact of the electrons on the resistive anode to four contact electrodes mounted on their periphery of the resistive anode into the spatial coordinates of electron impact.

Lampton, M. L.↗

SI IV Resonance Line Emission during Solar Flares: Non-LTE, Non-equilibrium, Radiation Transfer Simulations

The Interface Region Imaging Spectrograph routinely observes the Si IV resonance lines. When analyzing quiescent observations of these lines, it has typically been assumed that they form under optically thin conditions. This is likely valid for the quiescent Sun, but this assumption has also been applied to the more extreme flaring scenario. We used 36 electron-beam-driven radiation hydrodynamic solar flare simulations, computed using the RADYN code, to probe the validity of this assumption. Using these simulated atmospheres, we solved the radiation transfer equations to obtain the non-LTE, nonequilibrium populations, line profiles, and opacities for a model silicon atom, including charge exchange processes. This was achieved using the "minority species" version of RADYN. The inclusion of charge exchange resulted in a substantial fraction of Si IV at cooler temperatures than those predicted by ionization equilibrium. All simulations with an injected energy flux F> 5 x 10(exp 10) erg cm(exp -2) s(exp -1) resulted in optical depth effects on the Si IV emission, with differences in both intensity and line shape compared to the optically thin calculation. Weaker flares (down to F ~ 10(exp 9) erg cm(exp -2) s(exp -1)) also resulted in Si IV emission forming under optically thick conditions, depending on the other beam parameters. When opacity was significant, the atmospheres generally had column masses in excess of 5 x 10-6 g cm-2 over the temperature range 40-100 kK, and the Si IV formation temperatures were between 30 and 60 kK. We urge caution when analyzing Si IV flare observations, or when computing synthetic emission without performing a full radiation transfer calculation.

Kerr, Graham S.↗

A lunar rover powered by an orbiting laser diode array

A conceptual design of a high-power, long-duration lunar rover powered by a laser beam is proposed. The laser transmitter in lunar orbit consists of an SP-100 nuclear reactor prime power source providing 100 kW of electricity to a laser array that emits 50 kW of laser radiation. The laser radiation is beamed to the lunar surface where it is received by a GaAlAs solid-state, laser-to-electric converter. This converter provides 22 kW of electrical power to the rover vehicle for science, locomotion, and crew needs. The mass of the laser transmitter is approximately 5000 kg, whereas the mass of the rover power supply is 520 kg. The rover power unit is significantly less massive than alternative rover power units.

De Young, R. J.↗

Particulate sizes from polarization measurements

Radiation measurements from a ground based polarimeter were used to infer the optical properties of atmospheric particles. The inherent nonunigueness in model calculations is discussed. The inverse problem in atmospheric optics is described, along with incident and emergent beams. Emergent radiation was calculated for all possible particulate distributions, and results were catalogued.

Kuriyan, J. G.↗

Alterations in dose and lineal energy spectra under different shieldings in the Los Alamos high-energy neutron field

Nuclear interactions of space radiation with shielding materials result in alterations in dose and lineal energy spectra that depend on the specific elemental composition, density and thickness of the material. The shielding characteristics of materials have been studied using charged-particle beams and radiation transport models by examining the risk reduction using the conventional dose-equivalent approach. Secondary neutrons contribute a significant fraction of the total radiation exposure in space. An experiment to study the changes in dose and lineal energy spectra by shielding materials was carried out at the Los Alamos Nuclear Science Center neutron facility. In the energy range of about 2 to 200 MeV, this neutron spectrum is similar in shape within a factor of about 2 to the spectrum expected in the International Space Station habitable modules. It is shown that with a shielding thickness of about 5 g cm(-2), the conventional radiation risk increases, in some cases by as much as a factor of 2, but decreases with thicknesses of about of 20 g cm(-2). This suggests that care must be taken in evaluating the shielding effectiveness of a given material by including both the charged-particle and neutron components of space radiation.

NASA Discipline Radiation Health↗

Remote balance weighs accurately amid high radiation

Commercial beam-type balance, modified and outfitted with electronic controls and digital readout, can be remotely controlled for use in high radiation environments. This allows accurate weighing of breeder-reactor fuel pieces when they are radioactively hot.

Eggenberger, D. N.↗

Considerations for high accuracy radiation efficiency measurements for the Solar Power Satellite (SPS) subarrays

The relatively large apertures to be used in SPS, small half-power beamwidths, and the desire to accurately quantify antenna performance dictate the requirement for specialized measurements techniques. Objectives include the following: (1) For 10-meter square subarray panels, quantify considerations for measuring power in the transmit beam and radiation efficiency to + or - 1 percent (+ or - 0.04 dB) accuracy. (2) Evaluate measurement performance potential of far-field elevated and ground reflection ranges and near-field techniques. (3) Identify the state-of-the-art of critical components and/or unique facilities required. (4) Perform relative cost, complexity and performance tradeoffs for techniques capable of achieving accuracy objectives. the precision required by the techniques discussed below are not obtained by current methods which are capable of + or - 10 percent (+ or - dB) performance. In virtually every area associated with these planned measurements, advances in state-of-the-art are required.

Kozakoff, D. J.↗

Electron scattering and the distances to cluster cooling flows

Cluster cooling flows have electron-scattering optical depths which are estimated to be about 0.01. Many of the cluster-dominant galaxies centered in cluster cooling flows have active nuclei, and about 1 percent of the luminosity from the active nuclei should appear as diffuse, scattered radiation. It is shown here that detection of this scattered radiation at radio wavelengths can provide a measure of the distance to the cluster that is independent of the Hubble constant. Observations of the scattered surface brightness profile can also be used to test for clumpiness in the gas, for variations in the central radio source on time scales less than 100,000 yr, and for the degree of beaming of radiation from the central source.

Wise, Michael W.↗

Micro-Fresnel Zone Plate Optical Devices Using Densely Accumulated Ray Points

An embodiment generally relates to an optical device suitable for use with an optical medium for the storage and retrieval of data. The optical device includes an illumination means for providing a beam of optical radiation of wavelength .lamda. and an optical path that the beam of optical radiation follows. The optical device also includes a diffractive optical element defined by a plurality of annular sections. The plurality of annular sections having a first material alternately disposed with a plurality of annular sections comprising a second material. The diffractive optical element generates a plurality of focal points and densely accumulated ray points with phase contrast phenomena and the optical medium is positioned at a selected focal point or ray point of the diffractive optical element.

Choi, Sang H.↗

Two-Dimensional Array Beam Scanning Via Externally and Mutually Injection Locked Coupled Oscillators

Some years ago, Stephan proposed an approach to one dimensional (linear) phased array beam steering which requires only a single phase shifter. This involves the use of a linear array of voltage-controlled electronic oscillators coupled to nearest neighbors. The oscillators are mutually injection locked by controlling their coupling and tuning appropriately. Stephan's approach consists of deriving two signals from a master oscillator, one signal phase shifted with respect to the other by means of a single phase shifter. These two signals are injected into the end oscillators of the array. The result is a linear phase progression across the oscillator array. Thus, if radiating elements are connected to each oscillator and spaced uniformly along a line, they will radiate a beam at an angle to that line determined by the phase gradient which is, in turn, determined by the phase difference between the injection signals.The beam direction is therefore controlled by adjusting this phase difference. Recently, Pogorzelski and York presented a formulation which facilitates theoretical analysis of the above beam steering technique. This was subsequently applied by Pogorzelski in analysis of two dimensional beam steering using perimeter detuning of a coupled oscillator array. The formulation is based on a continuum model in which the oscillator phases are represented by a continuous function satisfying a partial differential equation of diffusion type. This equation can be solved via the Laplace transform and the resulting solution exhibits the dynamic behavior of the array as the beam is steered. Stephan's beam steering technique can be similarly generalized to two-dimensional arrays in which the beam control signals are applied to the oscillators on the perimeter of the array. In this paper the continuum model for this two-dimensional case is developed and the dynamic solution for the corresponding aperture phase function is obtained. The corresponding behavior of the resulting far-zone radiation pattern is displayed as well.

Pogorzelski, Ronald J.↗

Microfocus/Polycapillary-Optic Crystallographic X-Ray System

A system that generates an intense, nearly collimated, nearly monochromatic, small-diameter x-ray beam has been developed for use in macromolecular crystallography. A conventional x-ray system for macromolecular crystallography includes a rotating-anode x-ray source, which is massive (.500 kg), large (approximately 2 by 2 by 1 m), and power-hungry (between 2 and 18 kW). In contrast, the present system generates a beam of the required brightness from a microfocus source, which is small and light enough to be mounted on a laboratory bench, and operates at a power level of only tens of watts. The figure schematically depicts the system as configured for observing x-ray diffraction from a macromolecular crystal. In addition to the microfocus x-ray source, the system includes a polycapillary optic . a monolithic block (typically a bundle of fused glass tubes) that contains thousands of straight or gently curved capillary channels, along which x-rays propagate with multiple reflections. This particular polycapillary optic is configured to act as a collimator; the x-ray beam that emerges from its output face consists of quasi-parallel subbeams with a small angular divergence and a diameter comparable to the size of a crystal to be studied. The gap between the microfocus x-ray source and the input face of the polycapillary optic is chosen consistently with the focal length of the polycapillary optic and the need to maximize the solid angle subtended by the optic in order to maximize the collimated x-ray flux. The spectrum from the source contains a significant component of Cu K (photon energy is 8.08 keV) radiation. The beam is monochromatized (for Cu K ) by a nickel filter 10 m thick. In a test, this system was operated at a power of 40 W (current of 897 A at an accelerating potential of 45 kV), with an anode x-ray spot size of 41+/-2 microns. Also tested, in order to provide a standard for comparison, was a commercial rotating-anode x-ray crystallographic system with a pyrolytic graphite monochromator and a 250-micron pinhole collimator, operating at a power of 3.15 kW (current of 70 mA at an accelerating potential of 45 kV). The flux of collimated Cu K radiation in this system was found to be approximately 16 times that in the rotatinganode system. Data on x-ray diffraction from crystals of tetragonal form of lysozyme (protein) in this system were found to be of high quality and to be reducible by use of standard crystallographic software.

Joy, Marshall↗