Search NASA⌕ Search

SEARCH · Search NASA

Results for “CI testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Role of Genetic Polymorphisms in NFKB-Mediated Inflammatory Pathways in Response to Primary Chemoradiation Therapy for Rectal Cancer

Purpose: To investigate whether polymorphisms of genes related to inflammation are associated with pathologic response (primary endpoint) in patients with rectal cancer treated with primary chemoradiation therapy (PCRT). Methods and Materials: Genomic DNA of 159 patients with locally advanced rectal cancer treated with PCRT was genotyped for polymorphisms rs28362491 (NFKB1), rs1213266/rs5789 (PTGS1), rs5275 (PTGS2), and rs16944/rs1143627 (IL1B) using TaqMan single nucleotide polymorphism genotyping assays. The association between each genotype and pathologic response (poor response vs complete or partial response) was analyzed using logistic regression models. Results: The NFKB1 DEL/DEL genotype was associated with pathologic response (odds ratio [OR], 6.39; 95% confidence interval [CI], 0.78-52.65; P=.03) after PCRT. No statistically significant associations between other polymorphisms and response to PCRT were observed. Patients with the NFKB1 DEL/DEL genotype showed a trend for longer disease-free survival (log-rank test, P=.096) and overall survival (P=.049), which was not significant in a multivariate analysis that included pathologic response. Analysis for 6 polymorphisms showed that patients carrying the haplotype rs28362491-DEL/rs1143627-A/rs1213266-G/rs5789-C/rs5275-A/rs16944-G (13.7% of cases) had a higher response rate to PCRT (OR, 8.86; 95% CI, 1.21-64.98; P=.034) than the reference group (rs28362491-INS/rs1143627-A/rs1213266-G/rs5789-C/rs5275-A/rs16944-G). Clinically significant (grade ≥2) acute organ toxicity was also more frequent in patients with that same haplotype (OR, 4.12; 95% CI, 1.11-15.36; P=.037). Conclusions: Our results suggest that genetic variation in NFKB-related inflammatory pathways might influence sensitivity to primary chemoradiation for rectal cancer. If confirmed, an inflammation-related radiogenetic profile might be used to select patients with rectal cancer for preoperative combined-modality treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparing Cetane Number Measurement Methods

Cetane number is one of the most important fuel performance metrics for mixing controlled compression-ignition “diesel” engines, quantifying a fuel’s propensity for autoignition when injected into end-of-compression-type temperature and pressure conditions. The historical default and referee method on a Cooperative Fuel Research (CFR) engine configured with indirect fuel injection and variable compression ratio is cetane number (CN) rating. A subject fuel is evaluated against primary reference fuel blends, with heptamethylnonane defining a low-reactivity endpoint of CN = 15 and hexadecane defining a high-reactivity endpoint of CN = 100. While the CN scale covers the range from zero (0) to 100, typical testing is in the range of 30 to 65 CN. Alternatively, several constant-volume combustion chamber (CVCC)-based cetane rating devices have been developed to rate fuels with an equivalent derived cetane number (DCN) or indicated cetane number (ICN). These devices measure ignition delay for fuel injected into a fixed volume of high-temperature and high-pressure air to simulate end-of-compression-type conditions. In this study, a range of novel fuel compounds are evaluated across three CVCC methods: the Ignition Quality Tester (IQT), Fuel Ignition Tester (FIT), and Advanced Fuel Ignition Delay Analyzer (AFIDA). Resulting DCNs and ICNs are compared for fuels within the normal diesel fuel range of reactivity, as well as very high (~100) and very low DCNs/ICNs (~5). Distinct differences between results from various devices are discussed. This is important to consider because some new, high-efficiency advanced compression-ignition (CI) engine combustion strategies operate with more kinetically controlled distributed combustion as opposed to mixing controlled diffusion flames. These advanced combustion strategies may benefit from new fuel chemistries, but current rating methods of CN, DCN, and ICN may not fully describe their performance. In addition, recent evidence suggests ignition delay in modern on-road diesel engines with high-pressure common rail fuel injection systems may no longer directly correlate to traditional CN fuel ratings. Simulated end-of-compression conditions are compared for CN, DCN, and ICN and discussed in the context of modern diesel engines to provide additional insight. Results highlight the potential need for revised and/or multiple fuel test conditions to measure fuel performance for advanced CI strategies.

47 OTHER INSTRUMENTATION↗

Quantum Package 2.0: An Open-Source Determinant-Driven Suite of Programs

Quantum chemistry is a discipline which relies heavily on very expensive numerical computations. The scaling of correlated wave function methods lies, in their standard implementation, between O(N-5) and O(e(N)), where N is proportional to the system size. Therefore, performing accurate calculations on chemically meaningful systems requires (i) approximations that can lower the computational scaling and (ii) efficient implementations that take advantage of modern massively parallel architectures. QUANTUM PACKAGE is an open-source programming environment for quantum chemistry specially designed for wave function methods. Its main goal is the development of determinant-driven selected configuration interaction (sCI) methods and multireference second-order perturbation theory (PT2). The determinant-driven framework allows the programmer to include any arbitrary set of determinants in the reference space, hence providing greater methodological freedom. The sCI method implemented in QUANTUM PACKAGE is based on the CIPSI (Configuration Interaction using a Perturbative Selection made Iteratively) algorithm which complements the variational sCI energy with a PT2 correction. Additional external plugins have been recently added to perform calculations with multireference coupled cluster theory and range-separated density-functional theory. All the programs are developed with the IRPF90 code generator, which simplifies collaborative work and the development of new features. QUANTUM PACKAGE strives to allow easy implementation and experimentation of new methods, while making parallel computation as simple and efficient as possible on modern supercomputer architectures. Currently, the code enables, routinely, to realize runs on roughly 2 000 CPU cores, with tens of millions of determinants in the reference space. Moreover, we have been able to push up to 12 288 cores in order to test its parallel efficiency. In the present manuscript, we also introduce some key new developments: (i) a renormalized second-order perturbative correction for efficient extrapolation to the full CI limit and (ii) a stochastic version of the CIPSI selection performed simultaneously to the PT2 calculation at no extra cost.

Garniron, Yann↗

Reduced Temperature Cesium Removal from AP-101 Using Crystalline Silicotitanate

The Tank Side Cesium Removal (TSCR) system, currently operational under Washington River Protection Solutions LLC (WRPS), sends initial low-activity Hanford waste tank supernate feed to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIV™ R9140-B), was selected as the ion exchange media at TSCR. Laboratory-scale ion exchange processing using TSCR prototypic unit operations continues to contribute toward WRPS establishing accurate process flowsheets for the individual feed campaigns planned for TSCR. This report describes the small-scale ion exchange testing with 14.0 L of diluted and filtered supernate from tank 241-AP-101 (AP-101DF) at 16 °C (62 °F) to demonstrate processing at temperature conditions that are more prototypic of what the TSCR system could experience during colder seasons of the year. Since CST Cs capacity increases with decreasing contact temperature, testing at the lower operating temperature will help to predict the maximum 137 Cs loading onto the CST in the TSCR system. One of the waste acceptance criteria (WAC) for the WTP Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AP-101DF tank waste to meet this criterion, only 0.144% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 694. Testing with AP-101DF matched TSCR prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 62% Cs breakthrough after processing ~1400 BVs of feed; the 50% Cs breakthrough occurred at 1250 BVs. Testing compared to previous AP-107 testing at 16 °C showed ~80 BV increases in volume processed to reach the WAC limit for both lead and lag columns. A similar slope in breakthrough curves for both tests indicates similar kinetic behavior, with variations in feed matrices (Na and Cs concentrations) likely responsible for the deviations in reaching the WAC limit. The Cs effluent from the lag column reached the WAC limit after processing 875 BVs. Anticipating this breakthrough point, the polish column was preemptively installed at 770 BVs. Cs breakthrough from the lag column began at 300 BVs, reaching 5.32×10 0 µCi/mL, or 5.6 % Cs breakthrough, after processing all 1400 BVs of feed. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Light Duty Engine Performance Characteristics with Dimethyl Ether and Propane

Here, this paper explores the performance characteristics of a compression ignition HYUNDAI 2.2L engine operating with Dimethyl Ether (DME). Test are carried out at three operating conditions that weigh heavily in the FTP75 certification cycle (1000rpm-12Nm, 1500rpm-50Nm, 2000rpm-100Nm). The engine features a high-pressure common rail fuel injection system designed to operate with liquified gases. The main component of the fuel system is a high-pressure pump that incorporates an electronic inlet metering valve commanded on a crank-angle base to control the rail pressure. The pump, which requires no pressure regulator, provides the flow needed to the injectors without flow returning to the inlet. This novel fueling system is leveraged in tests that are conducted to examine the impact of EGR, combustion phasing, injection pressure on efficiency and emissions. In addition, the impact of introducing 15% Propane by mass is examined. During the tests, the engine ECU is aided by an Engine Controller High Speed Oversight unit (ECHO) to provide combustion phasing control, improved cylinder-to-cylinder uniformity, and an effective optimization over the testing effort. The use of DME and Propane allowed for peak thermal efficiency of nearly 43%. These fuels enable significant carbon index (CI) reductions over the baseline Diesel fuel, with indications that 50% reduction in CO 2 over the Diesel engine are possible.

33 ADVANCED PROPULSION SYSTEMS↗

Aqueous alteration on the parent bodies of carbonaceous chondrites: Computer simulations of late-stage oxidation

CI carbonaceous chondrites may be products of hydrous alteration of CV- or anhydrous CM-type materials. The CIs typically contain veins filled with carbonates and sulfates, probably indicating a period of late stage aqueous alteration under oxidizing conditions. To test this idea, computer simulations of aqueous alteration of CV- and CM-type carbonaceous were performed. Simulations were restricted to the oxidation of hydrous mineral assemblages produced in previous simulations in order to determine whether further reaction and oxidation results in the phyllosilicate, carbonate, sulfate and oxide vein assemblages typical of CI carbonaceous chondrites. Our simulations were performed at 1, 25, 100, and 150 C (the appropriate temperature range) for the CV and CM mineral assemblages and using the computer code EQ3/6.

Bourcier, W. L.↗

Ion Exchange Processing of AN-107 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System

The Hanford Site stores an estimated 56 million gallons of mixed radioactive and chemically hazardous waste in large underground tanks. In support of the Direct Feed Low-Activity Waste (DFLAW) Program for expediting Hanford tank waste supernate treatment, laboratory-scale ion exchange processing using prototypic unit operations was conducted on AN-107 tank waste at the Pacific Northwest National Laboratory Radiochemical Processing Laboratory. This report describes the small-scale ion exchange testing with 13.7 L of diluted and filtered supernate from Tank 241-AN-107 (hereafter referred to as AN-107) at 16 °C (62 °F). One of the waste acceptance criteria (WAC) for the Waste Treatment Plant (WTP) Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AN-107 tank waste to meet this criterion, only 0.147% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 678. Testing with AN-107 matched current Tank Side Cesium Removal (TSCR) facility prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the crystalline silicotitanate (CST) bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 40% Cs breakthrough after processing ~1700 BVs of feed; the 50% Cs breakthrough was extrapolated from the breakthrough data to occur at 1873 BVs. Testing compared to previous AP-101 and AP-107 testing at 16 °C showed ~300 BV increases in volume processed to reach the WAC limit for both lead and lag columns. The increase in capacity was determined to be due to the significantly lower K concentration in the AN-107 compared to the other tank waste matrices. A comparison in breakthrough curves for the three tests indicated slightly slower kinetic behavior in the AN-107, with variations in feed matrices (high organic complexants) likely responsible for the deviation. The Cs effluent from the lag column reached the WAC limit after processing 1097 BVs. Anticipating this breakthrough point, the polish column was preemptively installed around 900 BVs. Cs breakthrough from the lag column began at 500 BVs, reaching 3.06×10 0 µCi/mL, or 2.6 % Cs breakthrough, after processing all 1700 BVs of feed. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ion Exchange Processing of AW-105 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System

The Hanford Site stores an estimated 56 million gallons of mixed radioactive and chemically hazardous waste in large underground tanks. In support of the Direct Feed Low-Activity Waste (DFLAW) Program for expediting Hanford tank waste supernate treatment, laboratory-scale ion exchange processing using prototypic unit operations was conducted on AW-105 tank waste at the Pacific Northwest National Laboratory Radiochemical Processing Laboratory. This report describes the small-scale ion exchange testing with 9.2 L of diluted and filtered supernate from Tank 241-AW-105 (hereafter referred to as AW-105) at 16 °C (62 °F). One of the waste acceptance criteria (WAC) for the Waste Treatment Plant (WTP) Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AW-105 tank waste to meet this criterion, only 0.225% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 445. Testing with AW-105 matched current Tank Side Cesium Removal (TSCR) facility prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the crystalline silicotitanate (CST) bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 83% Cs breakthrough after processing ~1500 BVs of feed; the 50% Cs breakthrough was interpolated from the breakthrough data and occurred at 1041 BVs. Despite the AW-105 having a significantly higher K concentration (0.55 M compared to 0.10 M), testing compared to previous AP-107 ion exchange column testing at 16 °C showed no difference in BVs processed to reach the WAC on the lead column and only an approximate ~20 BV decrease in volume processed to reach the WAC limit on the lag column. The negligible differences in capacity despite the 5x concentration differences in K was determined to be due to the significantly lower NO3 concentration in the AW-105 supernate compared to the AP-107 tank waste matrix. A comparison in breakthrough curves for the two tests also indicated slightly faster kinetic behavior in the AW-105, with the variations in feed matrices (lower NO3 concentration) likely responsible for the deviation. The Cs effluent from the lag column reached the WAC limit after processing 772 BVs. Anticipating this breakthrough point, the polish column was preemptively installed around 675 BVs. Cs breakthrough from the lag column began at 300 BVs, reaching 1.10×10 1 µCi/mL, or 14.13 % Cs breakthrough, after processing all 1500 BVs of feed. The polish column processed nominally 830 BVs and reached 2.10×10 -1 µCi/mL, or 0.27 % Cs breakthrough at the conclusion of the test. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Revisiting benzene cluster cations for the chemical ionization of dimethyl sulfide and select volatile organic compounds

Benzene cluster cations were revisited as a sensitive and selective reagent ion for the chemical ionization of dimethyl sulfide (DMS) and a select group of volatile organic compounds (VOCs). Laboratory characterization was performed using both a new set of compounds (i.e., DMS, β -caryophyllene) as well as previously studied VOCs (i.e., isoprene, α -pinene). Using a field deployable chemical-ionization time-of-flight mass spectrometer (CI-ToFMS), benzene cluster cations demonstrated high sensitivity (> 1 ncps ppt &minus;1 ) to DMS, isoprene, and α -pinene standards. Parallel measurements conducted using a chemical-ionization quadrupole mass spectrometer, with a much weaker electric field, demonstrated that ion–molecule reactions likely proceed through a combination of ligand-switching and direct charge transfer mechanisms. Laboratory tests suggest that benzene cluster cations may be suitable for the selective ionization of sesquiterpenes, where minimal fragmentation (< 25 %) was observed for the detection of β -caryophyllene, a bicyclic sesquiterpene. The in-field stability of benzene cluster cations using CI-ToFMS was examined in the marine boundary layer during the High Wind Gas Exchange Study (HiWinGS). The use of benzene cluster cation chemistry for the selective detection of DMS was validated against an atmospheric pressure ionization mass spectrometer, where measurements from the two instruments were highly correlated ( R 2 > 0.95, 10 s averages) over a wide range of sampling conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The effect of school intervention programs on the body mass index of adolescents: a systematic review with meta-analysis

Abstract Effective obesity interventions in adolescent populations have been identified as an immediate priority action to stem the increasing prevalence of adult obesity. The purpose of this meta-analysis was to make a quantitative analysis of the impact of school-based interventions on body mass index during adolescence. Studies were retrieved from PubMed, Scopus, Science Direct and Web of Science databases. Results were pooled using a random-effects model with 95% confidence interval considered statistically significant. Of the 18 798 possible relevant articles identified, 12 articles were included in this meta-analysis. The global result showed a low magnitude effect, though it was statistically significant (N = 14 428), global e.s. = −0.055, P = 0.004 (95% CI = −0.092, −0.017). Heterogeneity was low among the studies (I2 = 9.017%). The funnel plot showed no evidence of publication bias. The rank-correlation test of Begg (P = 0.45641) and Egger’s regression (P = 0.19459) confirmed the absence of bias. This meta-analysis reported a significant effect favoring the interventions; however, future research are needed since the reported the evidence was of low magnitude, with the studies following a substantial range of approaches and mostly had a modest methodological quality.

Saavedra Dias, R.↗

An integral test of the inelastic cross sections of Pb and Mo using measured neutron spectra

Comparison of measurements and calculations of fast neutron spectra from a radioactive neutron source inside spheres of Mo or Pb and from a cylindrical reactor containing a thick Pb or Mo reflector are used as a test of ENDF cross sections. The sphere leakage spectra were measured at a sphere-to-spectrometer distance of 2 meters using a 54 Ci spherical Am-Be neutron source. Reactor leakage spectrum measurements were made at the surface of the ZP-1 reactor when bare, with a Pb radial reflector 21 cm thick, and with a metallic Mo radial reflector 10 cm thick. In the case of the thin Mo sphere there is agreement between the calculation and measurement. The Pb calculation is much lower than the measurement except at the highest neutron energy. Two-dimensional calculations of reactor spectra result indicate that the reactor source is reasonably well known. Significant differences in leakage spectrum shape for both Mo and Pb reflectors suggest that there are large uncertainties in the inelastic cross sections for Pb and some for Mo.

Shook, D. F.↗

Cesium Removal from SY-101 Tank Waste Using Crystalline Silicotitanate

The newly operational Tank Side Cesium Removal (TSCR) system removes radioactive cesium-137 ( 137 Cs) and solids from tank waste supernate in the 200 east area of the Hanford site. Efforts to expand the removal capabilities to the 200 west area are underway by a system anticipated to be called the West Area Risk Management (WARM) system. Laboratory-scale ion exchange processing using expected WARM unit operations were conducted to contribute toward Washington River Protection Solutions (WRPS) establishing accurate process flowsheets for the individual feed campaigns planned for the west area supernate pretreatment. This report describes the small-scale ion exchange testing with 8.0 L of filtered supernate from tank 241-SY-101 (referred to as SY-101) at 16 °C (62 °F) to demonstrate processing conditions that would be prototypic of what the WARM system may experience. One of the waste acceptance criteria (WAC) for the Waste Treatment Plant (WTP) Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the SY-101 tank waste to meet this criterion, only 0.44% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 227. Testing with SY-101 matched current TSCR prototypic operations where a lead-lag configuration is used until the lag column reached the WAC limit. Neither the lead nor lag columns reached the WAC, so a polish column was never utilized during this test. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the crystalline silicotitate (CST) bed, matched the current flowrate at TSCR (an expected flowrate to be used at WARM). The lead column only reached 0.09% Cs breakthrough after processing ~1363 BVs of feed. Cesium breakthrough from the lag column was not observed during the entire processing. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics. Table S.1 and Figure S.1 also summarize the measured SY-101 Cs load performance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analytical Performance Characteristics of the Cepheid GeneXpert Ebola Assay for the Detection of Ebola Virus

The recently developed Xpert® Ebola Assay is a novel nucleic acid amplification test for simplified detection of Ebola virus (EBOV) in whole blood and buccal swab samples. The assay targets sequences in two EBOV genes, lowering the risk for new variants to escape detection in the test. The objective of this report is to present analytical characteristics of the Xpert® Ebola Assay on whole blood samples. Our study evaluated the assay’s analytical sensitivity, analytical specificity, inclusivity and exclusivity performance in whole blood specimens. EBOV RNA, inactivated EBOV, and infectious EBOV were used as targets. The dynamic range of the assay, the inactivation of virus, and specimen stability were also evaluated. The lower limit of detection (LoD) for the assay using inactivated virus was estimated to be 73 copies/mL (95% CI: 51–97 copies/mL). The LoD for infectious virus was estimated to be 1 plaque-forming unit/mL, and for RNA to be 232 copies/mL (95% CI 163–302 copies/mL). The assay correctly identified five different Ebola viruses, Yambuku-Mayinga, Makona-C07, Yambuku-Ecran, Gabon-Ilembe, and Kikwit-956210, and correctly excluded all non-EBOV isolates tested. The conditions used by Xpert® Ebola for inactivation of infectious virus reduced EBOV titer by ≥6 logs. In conclusion, we found the Xpert® Ebola Assay to have high analytical sensitivity and specificity for the detection of EBOV in whole blood. It offers ease of use, fast turnaround time, and remote monitoring. The test has an efficient viral inactivation protocol, fulfills inclusivity and exclusivity criteria, and has specimen stability characteristics consistent with the need for decentralized testing. The simplicity of the assay should enable testing in a wide variety of laboratory settings, including remote laboratories that are not capable of performing highly complex nucleic acid amplification tests, and during outbreaks where time to detection is critical.

60 APPLIED LIFE SCIENCES↗

F-18 FDG PET for assessment of disease activity of large vessel vasculitis: A systematic review and meta-analysis

Background: The aim of this study is to investigate the performance of F-18 fluorodeoxyglucose positron emission tomography (F-18 FDG PET) or positron emission tomography/computed tomography (PET/CT) for the assessment of disease activity in patients with large vessel vasculitis (LVV) through a meta-analysis. Methods: The MEDLINE via PubMed and EMBASE were searched for the studies evaluating the performance of F-18 FDG PET or PET/CT in the assessment of disease activity in patients with LVV. Pooled sensitivity, specificity, diagnostic odds ratios (DORs), and summary receiver-operating characteristic (sROC) curve were estimated across the included studies. Possible publication bias was assessed by Deek’s funnel plot asymmetry tests. Results: A total of 439 PET images from 298 patients pooled from nine studies showed that the pooled sensitivity was 0.88 [95% confidence interval (CI) 0.79-0.93] without heterogeneity (χ{sup 2} = 14.42, P = .07) and the pooled specificity was 0.81 (95% CI 0.64-0.91) with heterogeneity (χ{sup 2} = 63.72, P = .00) for the detection of active LVV. The pooled DOR was 30 (95% CI 8-107). Hierarchical sROC curve indicates that the area under the curve was 0.91 (95% CI 0.89-0.94). There was no significant publication bias (P = .42), and meta-regression analysis revealed that none of the variables was the source of the study heterogeneity. Conclusions: F-18 FDG PET has a good performance for the detection of active disease status in patients with LVV. Revised criteria for the assessment of disease activity incorporated with F-18 FDG PET or PET/CT should be introduced and validated. Further studies are warranted to determine if PET-based treatment of LVV can improve outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enhancing Developer Productivity - L2 Milestone (Final Report)

This report documents the work done as part of the “Enhancing Developer Productivity” level 2 milestone. The team surveyed developers about impediments and successes; improved our CI pipeline monitoring and reporting; developed tools for line coverage reporting and analysis; improved compiler warning adherence in SIERRA; prototyped static analysis, AI, and mutation testing tooling in SIERRA; and developed a 3-5 year SIERRA plan document to help these initiatives continue past this milestone.

97 MATHEMATICS AND COMPUTING↗

Evaluating the Feasibility of Data Simulation for Radiation Research: Estimating RBE Values for HZE Radiation

As the drive for deep space exploration intensifies, a comprehensive understanding of the health effects of radiation exposure becomes paramount to the future of human space flight. However, epidemiological data for radiation exposure, particularly to high-energy (HZE) ions, is limited, partially due to the financial and logistical costs of radiation studies. As an alternative, this study aims to assess the viability of data simulation strategies to accurately model potential study parameters prior to utilizing laboratory conditions. This study estimates a relative biological effectiveness (RBE) factor based on the solid tumor data for outbred mice provided by Edmundson et al. 2020. Excess relative risk (ERR) models for HZE-Fe ions and gamma radiation were estimated using Poisson regression with Weibull models to represent the background solid tumor hazard without radiation. RBE values were calculated from the ratio of the heavy ion linear slope to the gamma linear slope. The parameters from these models were then applied to simulate iterations of 300 datasets across HZE-Fe doses of 0.05, 0.2, 0.4, and 0.75 Gy; gamma radiation doses of 0.75, 2, and 3 Gy, as well as an unirradiated control group. Sample size per dose varied from 100-500 mice across simulations (800-4000 mice total per dataset). 1500 datasets were generated total (300 each for sample sizes 800, 1600, 3200, and 4000). For each dataset, ERR per radiation type and RBE for HZE-Fe were calculated. The RBE from the Edmondson data was calculated to be 5.55. The RBEs from the simulated data converged around this value across the increasing sample sizes. For n = 4000, the mean RBE across the 300 datasets was 5.71 (95% CI: 5.47-5.95). These results suggest that RBEs calculated from simulated data are credible. Based on this exploration, data simulation is a viable method of testing radiation studies. It provides a method of testing study assumptions and refining research questions prior to embarking on costly laboratory experiments.

Sneha Mehta↗

Loading Capabilities of Irradiated 3-D Printed Polymers

Gamma radiation is the emission of a high-energy photon from a radioactive source. The photon then interacts with an atom potentially damaging it. While time has shown that gamma radiation has a little effect on metals, the same cannot be said about plastic. The use of these types of materials in radioactive areas has increased for many reasons ranging from the weight difference between plastics and metals to the costs associated with doing so. For example, a potential use for radiation resistant plastics could be longer lasting, cost effective, and light weight radiation detection devices sent to probe an area that may present unsafe conditions for humans to survey. For these reasons and more, finding a plastic polymer that can withstand radiation for an extended period of time would make a great impact on the nuclear industry. In this experiment, two different polymers will undergo a series of strength tests before and after being exposed to radiation after different amounts of time up to two weeks. There are two sets of plastic polymers that will be used. Each set will consist of an nonirradiated, control subset, and subsets subject to radiation for one day, one week, and two weeks. The radiation source is 1100 Ci cobalt- 60. The specimens are placed on a foam platform such that they will be exposed as evenly as possible. They are then lowered into the radiation chamber where they are surround by cobalt-60 sources and irradiated for the given amount of time. The specimens will be tested for tensile strength and flexural strength according to ASTM standards. For tensile testing, the specimen has a 'dog bone' shape. The specimen is gripped at the wide ends, and pulled away from the center at a constant rate until failure. To test flexural strength, the specimens will be subject to a 3-point bend test. The specimen is held in place by three points, center top side and both ends bottom side. Load is applied at a constant rate on the center of the specimen until failure. The calculations to be considered for comparison after performing these tests include the tensile strength and stress, elongation, flexural stress and strain, and elasticity. Once these tests are completed, testing specimens that have been 3D printed with different print orientations will be considered and tested. The results from both experiments will help create strong, radiation resistant products in a expeditious manner that could really push the current limitations and expand the use of radiation resistant material.

36 MATERIALS SCIENCE↗

Longitudinal SARS-CoV-2 seroprevalence in Portugal and antibody maintenance 12 months after infection

During the COVID-19 pandemic, Portugal has experienced three distinct SARS-CoV-2 infection waves. We previously documented the prevalence of SARS-CoV-2 immunity, measured by specific antibodies, in September 2020, 6 months after the initial moderate wave. Here, we show the seroprevalence changes 6 months later, up to the second week of March 2021, shortly following the third wave, which was one of the most severe in the world, and 2 months following the start of the vaccination campaign. A longitudinal epidemiological study was conducted, with a stratified quota sample of the Portuguese population. Serological testing was performed, including ELISA determination of antibody class and titers. The proportion of seropositives, which was 2.2% in September 2020, rose sharply to 17.3% (95% CI: 15.8–18.8%) in March 2021. Importantly, circulating IgG and IgA antibody levels were very stable 6 months after the initial determination and up to a year after initial infection, indicating long-lasting infection immunity against SARS-CoV-2. Moreover, vaccinated people had higher IgG levels from 3 weeks post-vaccination when compared with previously infected people at the same time post-infection.

60 APPLIED LIFE SCIENCES↗