Search NASA⌕ Search

SEARCH · Search NASA

Results for “CURRENT AMPLIFIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Demonstration of detuning and wavebreaking effects on Raman amplification efficiency in plasma

A plasma-based resonant backward Raman amplifier/compressor for high power amplification of short laser pulses might, under ideal conditions, convert as much as 90% of the pump energy to the seed pulse. While the theoretical highest possible efficiency of this scheme has not yet been achieved, larger efficiencies than ever before obtained experimentally (6.4%) are now being reported, and these efficiencies are accompanied by strong pulse compression. Based on these recent extensive experiments, it is now possible to deduce that the experimentally realized efficiency of the amplifier is likely constrained by two factors, namely the pump chirp and the plasma wavebreaking, and that these experimental observations may likely involve favorable compensation between the chirp of the laser and the density variation of the mediating plasma. Several methods for further improvement of the amplifier efficiency in current experiments are suggested.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance studies of Hamamatsu R9800 photomultiplier tube with a new active base designed for use in the Hall D Broadband tagger Hodoscope

This paper presents the results of a study of a high rate photomultiplier and active base assembly designed for use in scintillator counters of the Hall D Jefferson Lab Broadband fixed-array Tagging Hodoscope. In its standard configuration the fixed-array hodoscope consists of 218 plastic scintillator counters made with Hamamatsu R9800 one inch in diameter photomultiplier tube. All tubes are equipped with designed at JLab new active base. The base comprised of a high voltage divider integrated with amplifiers powered by current flowing through the divider (U.S. Patent No. 6,791,269). This original design allows limiting the PMT anode current to 15-20 uA at a 4 MHz count rate, and allows tube operation at lower high voltage bias voltage while retaining a desired overall gain and dynamic range of output signals. The performance of the PMT assemblies were studied at Jeffeson Lab using a picosecond laser (PLP-10). Subsequently, two hundred fifty PMT and base assemblies were manufactured and tested. The results of testing the R9800 photomultiplier in a new active base are presented and discussed.

Popov, Vladimir↗

Soil carbon cycling proxies: Understanding their critical role in predicting climate change feedbacks

The complexity of processes and interactions that drive soil C dynamics necessitate the use of proxy variables to represent soil characteristics that cannot be directly measured (correlative proxies), or that aggregate information about multiple soil characteristics into one variable (integrative proxies). These proxies have proven useful for understanding the soil C cycle, which is highly variable in both space and time, and are now being used to make predictions of the C fate and persistence under future climate scenarios. As these proxies are used at increasingly larger scales, the C pools and processes that proxies represent must be thoughtfully considered in order to minimize uncertainties in empirical understanding, as well as in model parameters and in model outcomes. The importance of these uncertainties is further amplified by the current need to make predictions of the C cycle for the non steady state environmental conditions resulting from global climate change. To clarify the appropriate uses of proxy variables, we provide specific examples of proxy variables that could improve decision making, adaptation choices, and modeling skill, while not foreclosing on – and also encouraging – continued work on their mechanistic underpinnings. We explore the use of three common soil proxies used to study soil organic matter: metabolic quotient, clay content, and physical fractionation. We also consider emerging data types, specifically genome-sequence data, and how these serve as proxies for microbial community activities. We opine that the demand for increasing mechanistic detail, and the flood of data from new imaging and genetic techniques, does not replace the value of correlative and integrative proxies--variables that are simpler, easier, or cheaper to measure. By closely examining the current knowledge gaps and broad assumptions in soil C cycling with the proxies already in use, we can develop new hypotheses and specify criteria for new and needed proxies.

Bailey, Vanessa L.↗

Water equivalent path length measurement in proton radiotherapy using time resolved diode dosimetry

Purpose: To verify water equivalent path length (WEPL) before treatment in proton radiotherapy using time resolved in vivo diode dosimetry. Methods: Using a passively scattered range modulated proton beam, the output of a diode driving a fast current-to-voltage amplifier is recorded at a number of depths in a water tank. At each depth, a burst of overlapping single proton pulses is observed. The rms duration of the burst is computed and the resulting data set is fitted with a cubic polynomial. Results: When the diode is subsequently set to an arbitrary depth and the polynomial is used as a calibration curve, the ''unknown'' depth is determined within 0.3 mm rms. Conclusions: A diode or a diode array, placed (for instance) in the rectum in conjunction with a rectal balloon, can potentially determine the WEPL at that point, just prior to treatment, with submillimeter accuracy, allowing the beam energy to be adjusted. The associated unwanted dose is about 0.2% of a typical single fraction treatment dose.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Harnessing Ultra-Intense Long-Wave Infrared Lasers: New Frontiers in Fundamental and Applied Research

This review explores two main topics: the state-of-the-art and emerging capabilities of high-peak-power, ultrafast (picosecond and femtosecond) long-wave infrared (LWIR) laser technology based on CO2 gas laser amplifiers, and the current and advanced scientific applications of this laser class. The discussion is grounded in expertise gained at the Accelerator Test Facility (ATF) of Brookhaven National Laboratory (BNL), a leading center for ultrafast, high-power CO2 laser development and a National User Facility with a strong track record in high-intensity physics experiments. We begin by reviewing the status of 9–10 μm CO2 laser technology and its applications, before exploring potential breakthroughs, including the realization of 100 terawatt femtosecond pulses. These advancements will drive ongoing research in electron and ion acceleration in plasma, along with applications in secondary radiation sources and atmospheric energy transport. Throughout the review, we highlight how wavelength scaling of physical effects enhances the capabilities of ultra-intense lasers in the LWIR spectrum, expanding the frontiers of both fundamental and applied science.

43 PARTICLE ACCELERATORS↗

Validation of picogram- and femtogram-input DNA libraries for microscale metagenomics

High-throughput sequencing libraries are typically limited by the requirement for nanograms to micrograms of input DNA. This bottleneck impedes the microscale analysis of ecosystems and the exploration of low biomass samples. Current methods for amplifying environmental DNA to bypass this bottleneck introduce considerable bias into metagenomic profiles. For this study, we describe and validate a simple modification of the Illumina Nextera XT DNA library preparation kit which allows creation of shotgun libraries from sub-nanogram amounts of input DNA. Community composition was reproducible down to 100 fg of input DNA based on analysis of a mock community comprising 54 phylogenetically diverse Bacteria and Archaea. The main technical issues with the low input libraries were a greater potential for contamination, limited DNA complexity which has a direct effect on assembly and binning, and an associated higher percentage of read duplicates. We recommend a lower limit of 1 pg (~100–1,000 microbial cells) to ensure community composition fidelity, and the inclusion of negative controls to identify reagent-specific contaminants. Applying the approach to marine surface water, pronounced differences were observed between bacterial community profiles of microliter volume samples, which we attribute to biological variation. This result is consistent with expected microscale patchiness in marine communities. We thus envision that our benchmarked, slightly modified low input DNA protocol will be beneficial for microscale and low biomass metagenomics.

100 fg↗

Simultaneous Solar Maximum Mission (SMM) and very large array observations of solar active regions

The research deals mainly with Very Large Array and Solar Maximum Mission observations of the ubiquitous coronal loops that dominate the structure of the low corona. As illustrated, the observations of thermal cyclotron lines at microwave wavelengths provide a powerful new method of accurately specifying the coronal magnetic field strength. Processes are delineated that trigger solar eruptions from coronal loops, including preburst heating and the magnetic interaction of coronal loops. Evidence for coherent burst mechanisms is provided for both the Sun and nearby stars, while other observations suggest the presence of currents that may amplify the coronal magnetic field to unexpectedly high levels. The existence is reported of a new class of compact, variable moving sources in regions of apparently weak photospheric field.

Lang, K. R.↗

Infrared Multiple-Quantum-Well Phototransistor

Proposed npn AlxGa1-xAs phototransistor incorporates multiple-quantum-well (MQW) infrared photodetector. Has n-doped contacts and is embedded between p-doped base region and n-doped collector region of transistor. Photocurrent amplified, and dark current suppressed.

Borenstain, Shmuel I.↗

Ab-Initio Description and Prediction of Properties of Carbon-Based and Other Non-Metallic Materials

We have resolved the long-standing problem consisting of 30%-50% theoretical underestimates of the band gaps of non-metallic materials. We describe the Bagayoko, Zhao, and Williams (BZW) method that rigorously circumvents the basis-set and variational effect presumed to be a cause of these underestimates. We present ab-initio, computational results that are in agreement with experiment for diamond (C), silicon (Si), silicon carbides (3C-SiC and 4H-SiC), and other semiconductors (GaN, BaTiO3, AlN, ZnSe, ZnO). We illustrate the predictive capability of the BZW method in the case of the newly discovered cubic phase of silicon nitride (c-Si3N4) and of selected carbon nanotabes [(10,0), and (8,4)]. Our conclusion underscores the inescapable need for the BZW method in ab-initio calculations that employ a basis set in a variational approach. Current nanoscale trends amplify this need. We estimate that the potential impact of applications of the BZW method in advancing our understanding of nonmetallic materials, in informing experiment, and particularly in guiding device design and fabrication is simply priceless.

Bagayoko, D.↗

Artificial Neural Network with Hardware Training and Hardware Refresh

A neural network circuit is provided having a plurality of circuits capable of charge storage. Also provided is a plurality of circuits each coupled to at least one of the plurality of charge storage circuits and constructed to generate an output in accordance with a neuron transfer function. Each of a plurality of circuits is coupled to one of the plurality of neuron transfer function circuits and constructed to generate a derivative of the output. A weight update circuit updates the charge storage circuits based upon output from the plurality of transfer function circuits and output from the plurality of derivative circuits. In preferred embodiments, separate training and validation networks share the same set of charge storage circuits and may operate concurrently. The validation network has a separate transfer function circuits each being coupled to the charge storage circuits so as to replicate the training network s coupling of the plurality of charge storage to the plurality of transfer function circuits. The plurality of transfer function circuits may be constructed each having a transconductance amplifier providing differential currents combined to provide an output in accordance with a transfer function. The derivative circuits may have a circuit constructed to generate a biased differential currents combined so as to provide the derivative of the transfer function.

Tuan A Duong↗

Cryogenic microcalorimeter system for ultra-high resolution alpha-particle spectrometry

Microcalorimeters have been shown to yield unsurpassed energy resolution for alpha spectrometry, up to 1.06 keV FWHM at 5.3 MeV. These detectors use a superconducting transition-edge sensor (TES) to measure the temperature change in an absorber from energy deposited by an interacting alpha particle. Our system has four independent detectors mounted inside a liquid nitrogen/liquid helium cryostat. An adiabatic demagnetization refrigerator (ADR) cools the detector stage to its operating temperature of 80 mK. Temperature regulation with {approx}15 uK peak-to-peak variation is achieved by PID control of the ADR. The detectors are voltage-biased, and the current signal is amplified by a commercial SQUID readout system and digitized for further analysis, This paper will discuss design and operation of our microcalorimeter alpha spectrometer, and will show recent results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fluid amplifier state of the art. volume i- research and development - fluid amplifiers and logic

The report surveys the current state-of-the-art of fluid amplifiers including both theoretical and practical aspects of devices having no mechanically moving parts. It is based on a complete review of the published literature (with an extensive bibliography), information obtained from 20 organizations involved in fluid amplifier development, and work performed by the General Electric Company. Specific areas covered are design techniques, both analytical and experimental; typical elements and assemblies; applications, both now in use and contemplated; fabrication techniques; and instrumentation. The report concludes that, although simple applications are now being made, the fluid amplifier field is still in the early development stage. There continues to be a basis for optimism for space applications requiring extreme environmental tolerance, long life, or the elimination of fluid system interfaces. Specialized military, and commercial applications also look promising. Work now under way should provide a better understanding of the design of devices and increase the number of useful applications.

FLUID AMPLIFICATION↗

Single Frequency, Pulsed Laser Diode Transmitter for Dial Water Vapor Measurements at 935nm

We report a tunable, single frequency, narrow linewidth, pulsed laser diode transmitter at 935.68nm for remote sensing of atmospheric water vapor. The transmitter consists of a CW, tunable, external cavity diode laser whose output is amplified 2OdB using a tapered diode amplifier. The output is pulsed for range resolved DIAL lidar by pulsing the drive current to the diode amplifier at 4kHz with a .5% duty cycle. The output from the transmitter is 36OnJ/pulse and is single spatial mode. It maintains a linewidth of less than 25MHz as its wavelength is tuned across the water vapor absorption line at 935.68nm. The transmitter design and its use in a water vapor measurement will be discussed.

Switzer, Gregg W.↗

The Regenerative Current Mirror: A Very Low Power Front-End Amplifier for Silicon Pixel Detectors

In pixelized detectors, reducing power consumption in the front- end ASIC chips becomes a crucial demand. Optimization based on mature pre-amplifier schemes today is unlikely to bring sufficient improvements. A new CMOS front-end gain stage topology with very low power consumption called regenerative current mirror is developed to fulfill the demand. The circuit takes advantage of high-speed performance of current amplification while operating with relatively low bias current. The regenerative current mirror uses a NMOS current mirror and a PMOS current mirror, both with nominal gain of 1, to form a loop-back topology that provides a positive feedback. An NMOS FET with an external adjustable voltage applied to it gate terminal is used to limit open loop gain of the current mirrors to be slightly lower than 1. This yields a net gain of the positive feedback loop to be much larger than 1 while operating the current mirrors under relatively low bias currents. Simulation shows that in 65 nm fabrication process, the power consumption of the gain stages suitable for silicon pixel detectors can be controlled < 10 micro-Watts per channel. Another novel low-power circuit called Pseudo-Thyristor presented in another document will replace traditional discriminator and the Regenerative Current Mirror plus Pseudo- Thyristor will provide a full solution for the silicon pixel low-power frontend ASIC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Regenerative Current Mirror: A Very Low Power Front-End Amplifier for Silicon Pixel Detectors

In pixelized detectors, reducing power consumption in the front end ASIC chips becomes a crucial demand. Optimization based on mature pre-amplifier schemes today is unlikely to bring sufficient improvements. A new CMOS front-end gain stage topology with very low power consumption called regenerative current mirror is developed to fulfill the demand. The circuit takes advantage of high speed performance of current amplification while operating with relatively low bias current. The regenerative current mirror uses a NMOS current mirror and a PMOS current mirror, both with nominal gain of 1, to form a loop-back topology that provides a positive feedback. An NMOS FET with an external adjustable voltage applied to it gate terminal is used to limit open loop gain of the current mirrors to be slightly lower than 1. This yields a net gain of the positive feedback loop to be much larger than 1 while operating the current mirrors under relatively low bias currents. Simulation shows that in 65 nm fabrication process, the power consumption of the gain stages suitable for silicon pixel detectors can be controlled < 10 micro-Watts per channel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Re-evaluating probable maximum precipitation estimates: sensitivity to transposition domains and storm rotation using modern datasets

This study examines the sensitivity of Probable Maximum Precipitation (PMP) estimates to key methodological decisions embedded in the legacy approach adopted in the U.S. National Weather Service Hydrometeorological Reports No. 51 and No. 52. Although widely used for infrastructure design and risk regulation, fundamental aspects of PMP estimation—such as storm sample size, transposition domain, maximization procedures, and storm rotation—remain poorly constrained and lack formal guidance. Using the Red Rock watershed in Iowa as a case study, and leveraging the 2002–2023 NOAA Analysis of Record for Calibration (AORC) precipitation dataset, we systematically evaluate how each methodological choice, individually and in combination, influences PMP estimates. Our findings demonstrate that PMP is not a fixed physical upper bound but rather a modeling construct shaped heavily by user-defined assumptions. Notably, PMP values derived from modern gridded rainfall datasets can be substantially higher than the legacy estimate used in the original spillway design for Red Rock Dam. Decisions regarding storm sample size, domain extent, climatological window, and particularly storm rotation all contributed to higher PMP estimates. Storm rotation alone—a loosely constrained element in the current PMP practice—can amplify PMP by more than 25%. These results reveal the lack of standardized bounds in current PMP workflows and the need for systematic sensitivity and uncertainty analysis. As PMP estimation shifts toward probabilistic approaches, incorporating physically meaningful storm attributes will be key to developing more transparent, defensible methods for dam safety and climate-resilient infrastructure.

Probable maximum precipitation↗

Low phase noise oscillator using two parallel connected amplifiers

A high frequency oscillator is provided by connecting two amplifier circuits in parallel where each amplifier circuit provides the other amplifier circuit with the conditions necessary for oscillation. The inherent noise present in both amplifier circuits causes the quiescent current, and in turn, the generated frequency, to change. The changes in quiescent current cause the transconductance and the load impedance of each amplifier circuit to vary, and this in turn results in opposing changes in the input susceptance of each amplifier circuit. Because the changes in input susceptance oppose each other, the changes in quiescent current also oppose each other. The net result is that frequency stability is enhanced.

Kleinberg, Leonard L.↗