Search NASA⌕ Search

SEARCH · Search NASA

Results for “Count”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

TU-F-18A-08: Effect of Quantum Detection Efficiency and Energy Bin Selection On Contrast-To-Noise-Ratio for Energy-Resolved Photon-Counting Detectors

Purpose: Energy-resolved photon-counting detectors have the capability to discriminate photons according to their energies. By using optimal energy weighting factors, the contrast-to-noise-ratio (CNR) of the reconstructed image can be improved. In this work, we investigate how quantum detection efficiency (QDE) affects the determination of the optimal energy threshold bins, and therefore the CNR improvement of photon-counting detectors. Methods: In this simulation study a photon-counting detector, based on Silicon (Si), was investigated. A task-oriented algorithm was used to determine the optimal energy bin setting in order to maximize CNR. Projection-based and Image-based energy weighting techniques were implemented. A 13 mm PMMA phantom with two contrast materials, hydroxyapatite (HA) and iodine (I), at different concentrations (100, 200, and 300 mg/mL for HA and 2, 4, and 8 mg/mL for I) was used. TASMIP algorithm was used to generate the spectrum with 2.7 mm Al filter. Different tube voltages, number of energy bins, and bin widths were investigated. Different thicknesses of Si were also investigated to determine the QDE effect on CNR. Results: CNR increased as the detector material thickness increased until it reached 30 mm for Si thickness such that the CNR value was near to the value predicted by an ideal detector. Also, the results indicated that the improvement of CNR due to the QDE is task-dependent when comparing weighted images to photon-counting images. For hydroxyapatite the improvement is approximately 20%, whereas for iodine it is less than 10%. Conclusion: The results showed that the improvement of CNR for an energy-resolved photon-counting detector is highly task-dependent when QDE is taken into account.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing energy dependence and count rate performance of a dual scintillator fiber-optic detector for computed tomography

Purpose: Kilovoltage (kV) x-rays pose a significant challenge for radiation dosimetry. In the kV energy range, even small differences in material composition can result in significant variations in the absorbed energy between soft tissue and the detector. In addition, the use of electronic systems in light detection has demonstrated measurement losses at high photon fluence rates incident to the detector. This study investigated the feasibility of using a novel dual scintillator detector and whether its response to changes in beam energy from scatter and hardening is readily quantified. The detector incorporates a tissue-equivalent plastic scintillator and a gadolinium oxysulfide scintillator, which has a higher sensitivity to scatter x-rays. Methods: The detector was constructed by coupling two scintillators: (1) small cylindrical plastic scintillator, 500 μm in diameter and 2 mm in length, and (2) 100 micron sheet of gadolinium oxysulfide 500 μm in diameter, each to a 2 m long optical fiber, which acts as a light guide to transmit scintillation photons from the sensitive element to a photomultiplier tube. Count rate linearity data were obtained from a wide range of exposure rates delivered from a radiological x-ray tube by adjusting the tube current. The data were fitted to a nonparalyzable dead time model to characterize the time response. The true counting rate was related to the reference free air dose air rate measured with a 0.6 cm{sup 3} Radcal{sup ®} thimble chamber as described in AAPM Report No. 111. Secondary electron and photon spectra were evaluated using Monte Carlo techniques to analyze ionization quenching and photon energy-absorption characteristics from free-in-air and in phantom measurements. The depth/energy dependence of the detector was characterized using a computed tomography dose index QA phantom consisting of nested adult head and body segments. The phantom provided up to 32 cm of acrylic with a compatible 0.6 cm{sup 3} calibrated ionization chamber to measure the reference air kerma. Results: Each detector exhibited counting losses of 5% when irradiated at a dose rate of 26.3 mGy/s (Gadolinium) and 324.3 mGy/s (plastic). The dead time of the gadolinium oxysulfide detector was determined to be 48 ns, while the dead time of the plastic scintillating detector was unable to accurately be calculated due to poor counting statistics from low detected count rates. Noticeable depth/energy dependence was observed for the plastic scintillator for depths greater than 16 cm of acrylic that was not present for measurements using the gadolinium oxysulfide scintillator, leading us to believe that quenching may play a larger role in the depth dependence of the plastic scintillator than the incident x-ray energy spectrum. When properly corrected for dead time effects, the energy response of the gadolinium oxysulfide scintillator is consistent with the plastic scintillator. Using the integrated dual detector method was superior to each detector individually as the depth-dependent measure of dose was correctable to less than 8% between 100 and 135 kV. Conclusions: The dual scintillator fiber-optic detector accommodates a methodology for energy dependent corrections of the plastic scintillator, improving the overall accuracy of the dosimeter across the range of diagnostic energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigating the limits of PET/CT imaging at very low true count rates and high random fractions in ion-beam therapy monitoring

Purpose: External beam radiotherapy with protons and heavier ions enables a tighter conformation of the applied dose to arbitrarily shaped tumor volumes with respect to photons, but is more sensitive to uncertainties in the radiotherapeutic treatment chain. Consequently, an independent verification of the applied treatment is highly desirable. For this purpose, the irradiation-induced β{sup +}-emitter distribution within the patient is detected shortly after irradiation by a commercial full-ring positron emission tomography/x-ray computed tomography (PET/CT) scanner installed next to the treatment rooms at the Heidelberg Ion-Beam Therapy Center (HIT). A major challenge to this approach is posed by the small number of detected coincidences. This contribution aims at characterizing the performance of the used PET/CT device and identifying the best-performing reconstruction algorithm under the particular statistical conditions of PET-based treatment monitoring. Moreover, this study addresses the impact of radiation background from the intrinsically radioactive lutetium-oxyorthosilicate (LSO)-based detectors at low counts. Methods: The authors have acquired 30 subsequent PET scans of a cylindrical phantom emulating a patientlike activity pattern and spanning the entire patient counting regime in terms of true coincidences and random fractions (RFs). Accuracy and precision of activity quantification, image noise, and geometrical fidelity of the scanner have been investigated for various reconstruction algorithms and settings in order to identify a practical, well-suited reconstruction scheme for PET-based treatment verification. Truncated listmode data have been utilized for separating the effects of small true count numbers and high RFs on the reconstructed images. A corresponding simulation study enabled extending the results to an even wider range of counting statistics and to additionally investigate the impact of scatter coincidences. Eventually, the recommended reconstruction scheme has been applied to exemplary postirradiation patient data-sets. Results: Among the investigated reconstruction options, the overall best results in terms of image noise, activity quantification, and accurate geometrical recovery were achieved using the ordered subset expectation maximization reconstruction algorithm with time-of-flight (TOF) and point-spread function (PSF) information. For this algorithm, reasonably accurate (better than 5%) and precise (uncertainty of the mean activity below 10%) imaging can be provided down to 80 000 true coincidences at 96% RF. Image noise and geometrical fidelity are generally improved for fewer iterations. The main limitation for PET-based treatment monitoring has been identified in the small number of true coincidences, rather than the high intrinsic random background. Application of the optimized reconstruction scheme to patient data-sets results in a 25% − 50% reduced image noise at a comparable activity quantification accuracy and an improved geometrical performance with respect to the formerly used reconstruction scheme at HIT, adopted from nuclear medicine applications. Conclusions: Under the poor statistical conditions in PET-based treatment monitoring, improved results can be achieved by considering PSF and TOF information during image reconstruction and by applying less iterations than in conventional nuclear medicine imaging. Geometrical fidelity and image noise are mainly limited by the low number of true coincidences, not the high LSO-related random background. The retrieved results might also impact other emerging PET applications at low counting statistics.

60 APPLIED LIFE SCIENCES↗

An efficient computational approach to model statistical correlations in photon counting x-ray detectors

Purpose: To introduce and evaluate an increment matrix approach (IMA) describing the signal statistics of energy-selective photon counting detectors including spatial–spectral correlations between energy bins of neighboring detector pixels. The importance of the occurring correlations for image-based material decomposition is studied. Methods: An IMA describing the counter increase patterns in a photon counting detector is proposed. This IMA has the potential to decrease the number of required random numbers compared to Monte Carlo simulations by pursuing an approach based on convolutions. To validate and demonstrate the IMA, an approximate semirealistic detector model is provided, simulating a photon counting detector in a simplified manner, e.g., by neglecting count rate-dependent effects. In this way, the spatial–spectral correlations on the detector level are obtained and fed into the IMA. The importance of these correlations in reconstructed energy bin images and the corresponding detector performance in image-based material decomposition is evaluated using a statistically optimal decomposition algorithm. Results: The results of IMA together with the semirealistic detector model were compared to other models and measurements using the spectral response and the energy bin sensitivity, finding a good agreement. Correlations between the different reconstructed energy bin images could be observed, and turned out to be of weak nature. These correlations were found to be not relevant in image-based material decomposition. An even simpler simulation procedure based on the energy bin sensitivity was tested instead and yielded similar results for the image-based material decomposition task, as long as the fact that one incident photon can increase multiple counters across neighboring detector pixels is taken into account. Conclusions: The IMA is computationally efficient as it required about 10{sup 2} random numbers per ray incident on a detector pixel instead of an estimated 10{sup 8} random numbers per ray as Monte Carlo approaches would need. The spatial–spectral correlations as described by IMA are not important for the studied image-based material decomposition task. Respecting the absolute photon counts and thus the multiple counter increases by a single x-ray photon, the same material decomposition performance could be obtained with a simpler detector description using the energy bin sensitivity.

60 APPLIED LIFE SCIENCES↗

Characterizing Shielded Special Nuclear Material by Neutron Capture Gamma-Ray Multiplicity Counting

We present a new neutron multiplicity counting analysis and measurement method for neutron-shielded fissile material using neutron-capture gamma rays. Neutrons absorbed in shielding produce characteristic gamma rays that preserve the otherwise lost neutron multiplicity signature. Neutron multiplicity counting provides estimates of fission parameters, such as neutron leakage multiplication, spontaneous fissioner (e.g. Pu-240) mass, and (α,n) ratio. Standard neutron multiplicity counting can incorporate the new neutron-capture gamma-ray multiplicity counting technique to characterize previously degenerate or intractable source configurations by maximizing the multiplicity signature. The new method decouples neutron source-detector interferences, such as reflection and thermalization time in the detector, that could improve measurements of the mean neutron lifetime. We also develop a detector prototype for the multiplicity counting of neutron-capture gamma rays and present detector design considerations, such as detection material and shielding, to optimize the detection of the 2.2 MeV hydrogen capture gamma ray. We simulate the prototype neutron- capture gamma-ray multiplicity counter against the BeRP ball in polyethylene shells to inform future measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Zero-Truncated Poisson Tensor Decomposition for Sparse Count Data

We propose a novel statistical inference paradigm for zero-inflated multiway count data that dispenses with the need to distinguish between true and false zero counts. Our approach ignores all zero entries and applies zero-truncated Poisson regression on the positive counts. Inference is accomplished via tensor completion that imposes low-rank structure on the Poisson parameter space. Our main result shows that an $\textit{N}$-way rank-R parametric tensor 𝓜 ϵ (0, ∞) $I$Χ∙∙∙Χ$I$ generating Poisson observations can be accurately estimated from approximately $IR^2 \text{log}^2_2(I)$ non-zero counts for a nonnegative canonical polyadic decomposition. Several numerical experiments are presented demonstrating that our zero-truncated paradigm is comparable to the ideal scenario where the locations of false zero counts are known $\textit{a priori}$.

97 MATHEMATICS AND COMPUTING↗

Systematic effects in neutron coincidence and multiplicity counting

Correlated neutron counting, including neutron coincidence and multiplicity counting, is an important tool in nuclear material accountancy verification. The accuracy of such measurements is of interest to the safeguards community because as the accuracy of NDA improves, the number of samples that are required to undergo destructive analysis (DA) decreases. The accuracy of a neutron mUltiplicity measurement can be affected by a number of variables. Monte Carlo neutron transport simulations with MCNPX have been performed to understand how the properties of the sample affect the count rate. These resultant count rates have been analyzed with the 'point model' in order to determine the effect on the deduced plutonium mass. The sample properties that have been investigated are density, sample position within the detector cavity, moisture content, isotopic composition, plutonium to total actinide ratio and heavy metal fraction. These parameters affect the Singles, Doubles and Triples count rates in different ways. In addition, different analysis methods use these measured quantities in different combinations, so that the final sensitivity of the {sup 240}Pu mass to each parameter also depends on the analysis method used. For example, the passive calibration curve method only used the Doubles rate to produce the {sup 240}Pu mass and so is not sensitive to changes in the Singles rate (to first order). The analysis methods considered here were passive calibration curve (non-multiplication corrected), known alpha (multiplication corrected) and multiplicity with known efficiency. The effects were studied on both a small mass MOX sample (1 g Pu) and a large MOX sample (6000 g Pu) both measured in high efficiency neutron multiplicity counters. In order to determine the final effect of each parameter it is necessary to know not only the sensitivity of the plutonium mass to that parameter, but also the range over which the parameter can realistically vary. Some estimates are given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Linear fitting of multi-threshold counting data

The present disclosure provides a system and method for efficiently mining multi-threshold measurements acquired using photon counting pixel-array detectors for spectral imaging and diffraction analyses. Images of X-ray intensity as a function of X-ray energy were recorded on a 6 megapixel X-ray photon counting array detector through linear fitting of the measured counts recorded as a function of counting threshold. An analytical model is disclosed for describing the probability density of detected voltage, utilizing fractional photon counting to account for edge/corner effects from voltage plumes that spread across multiple pixels. Three-parameter fits to the model were independently performed for each pixel in the array for X-ray scattering images acquired for 13.5 keV and 15.0 keV X-ray energies. From the established pixel responses, multi-threshold composite images produced from the sum of 13.5 keV and 15.0 keV data can be analytically separated to recover the monochromatic images through simple linear fitting.

47 OTHER INSTRUMENTATION↗

Faster approximate subgraph counts with privacy

One of the most common problems studied in the context of differential privacy for graph data is counting the number of non-induced embeddings of a subgraph in a given graph. These counts have very high global sensitivity. Therefore, adding noise based on powerful alternative techniques, such as smooth sensitivity and higher-order local sensitivity have been shown to give significantly better accuracy. However, all these alternatives to global sensitivity become computationally very expensive, and to date efficient polynomial time algorithms are known only for few selected subgraphs, such as triangles, k-triangles, and k-stars. In this paper, we show that good approximations to these sensitivity metrics can be still used to get private algorithms. Using this approach, we much faster algorithms for privately counting the number of triangles in real-world social networks, which can be easily parallelized. We also give a private polynomial time algorithm for counting any constant size subgraph using less noise than the global sensitivity; we show this can be improved significantly for counting paths in special classes of graphs

Nguyen, Dung↗

PhotonIDs: ML-Powered Photon Identification System for Dark Count Elimination

Reliable single photon detection is the foundation for practical quantum communication and networking. However, today's superconducting nanowire single photon detector(SNSPD) inherently fails to distinguish between genuine photon events and dark counts, leading to degraded fidelity in long-distance quantum communication. In this work, we introduce PhotonIDs, a machine learning-powered photon identification system that is the first end-to-end solution for real-time discrimination between photons and dark count based on full SNSPD readout signal waveform analysis. PhotonIDs ~demonstrates: 1) an FPGA-based high-speed data acquisition platform that selectively captures the full waveform of signal only while filtering out the background data in real time; 2) an efficient signal preprocessing pipeline, and a novel pseudo-position metric that is derived from the physical temporal-spatial features of each detected event; 3) a hybrid machine learning model with near 98% accuracy achieved on photon/dark count classification. Additionally, proposed PhotonIDs ~ is evaluated on the dark count elimination performance with two real-world case studies: (1) 20 km quantum link, and (2) Erbium ion-based photon emission system. Our result demonstrates that PhotonIDs ~could improve more than 31.2 times of signal-noise-ratio~(SNR) on dark count elimination. PhotonIDs ~ marks a step forward in noise-resilient quantum communication infrastructure.

Linne, Karl C. [Chicago U.] (ORCID:000900091870358↗

Estimating the Effective System Dead Time Parameter for Correlated Neutron Counting

We present that neutron time correlation analysis is one of the main technical nuclear safeguards techniques used to verify declarations of, or to independently assay, special nuclear materials. Quantitative information is generally extracted from the neutron-event pulse train, collected from moderated assemblies of 3 He proportional counters, in the form of correlated count rates that are derived from event-triggered coincidence gates. These count rates, most commonly referred to as singles, doubles and triples rates etc., when extracted using shift-register autocorrelation logic, are related to the reduced factorial moments of the time correlated clusters of neutrons emerging from the measurement items. Correcting these various rates for dead time losses has received considerable attention recently. The dead time losses for the higher moments in particular, and especially for large mass (high rate and highly multiplying) items, can be significant. Consequently, even in thoughtfully designed systems, accurate dead time treatments are needed if biased mass determinations are to be avoided. In support of this effort, in this paper we discuss a new approach to experimentally estimate the effective system dead time of neutron coincidence counting systems. It involves counting a random neutron source (e.g. AmLi is a good approximation to a source without correlated emission) and relating the second and higher moments of the neutron number distribution recorded in random triggered interrogation coincidence gates to the effective value of dead time parameter. We develop the theoretical basis of the method and apply it to the Oak Ridge Large Volume Active Well Coincidence Counter using sealed AmLi radionuclide neutron sources and standard multiplicity shift register electronics. The method is simple to apply compared to the predominant present approach which involves using a set of 252 Cf sources of wide emission rate, it gives excellent precision in a conveniently short time, and it yields consistent results as a function of the order of the moment used to extract the dead time parameter. In addition, this latter observation is reassuring in that it suggests the assumptions underpinning the theoretical analysis are fit for practical application purposes. However, we found that the effective dead time parameter obtained is not constant, as might be expected for a parameter that in the dead time model is characteristic of the detector system, but rather, varies systematically with gate width.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Extension of the Dytlewski-style dead time correction formalism for neutron multiplicity counting to any order

Here, neutron multiplicity counting using shift-register calculus is an established technique in the science of international nuclear safeguards for the identification, verification, and assay of special nuclear materials. Typically passive counting is used for Pu and mixed Pu-U items and active methods are used for U materials. Three measured counting rates, singles, doubles and triples are measured and, in combination with a simple analytical point-model, are used to calculate characteristics of the measurement item in terms of known detector and nuclear parameters. However, the measurement problem usually involves more than three quantities of interest, but even in cases where the next higher order count rate, quads, is statistically viable, it is not quantitatively applied because corrections for dead time losses are currently not available in the predominant analysis paradigm. In this work we overcome this limitation by extending the commonly used dead time correction method, developed by Dytlewski, to quads. We also give results for pents, which may be of interest for certain special investigations. Extension to still higher orders, may be accomplished by inspection based on the sequence presented. We discuss the foundations of the Dytlewski method, give limiting cases, and highlight the opportunities and implications that these new results expose. In particular there exist a number of ways in which the new results may be combined with other approaches to extract the correlated rates, and this leads to various practical implementations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-fast photon counting with a passive quenching silicon photomultiplier in the charge integration regime

An ultra-fast photon counting method is proposed based on the charge integration of output electrical pulses of passive quenching silicon photomultipliers (SiPMs). The results of the numerical analysis with actual parameters of SiPMs show that the maximum photon counting rate of a state-of-art passive quenching SiPM can reac ∼ THz levels which is much larger than that of the existing photon counting devices. The experimental procedure is proposed based on this method. This photon counting regime of SiPMs is promising in many fields such as large dynamic light power detection. (photon detectors)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Calibration of the Accuscan II In Vivo System for Whole Body Counting

This report describes the April 2011 calibration of the Accuscan II HpGe In Vivo system for whole body counting. The source used for the calibration was a NIST traceable BOMAB manufactured by DOE as INL2006 BOMAB containing Eu-154, Eu-155, Eu-152, Sb-125 and Y-88 with energies from 27 keV to 1836 keV with a reference date of 11/29/2006. The actual usable energy range was 86.5 keV to 1597 keV on 4/21/2011. The BOMAB was constructed inside the Accuscan II counting 'tub' in the order of legs, thighs, abdomen, thorax/arms, neck, and head. Each piece was taped to the backwall of the counter. The arms were taped to the thorax. The phantom was constructed between the v-ridges on the backwall of the Accuscan II counter. The energy and efficiency calibrations were performed using the INL2006 BOMAB. The calibrations were performed with the detectors in the scanning mode. This report includes an overview introduction and records for the energy/FWHM and efficiency calibration including performance verification and validation counting. The Accuscan II system was successfully calibrated for whole body counting and verified in accordance with ANSI/HPS N13.30-1996 criteria.

61 RADIATION PROTECTION AND DOSIMETRY↗

Correlated neutron counting for the 21st century

Correlated neutron counting techniques, such as neutron coincidence and multiplicity counting, are widely employed at nuclear fuel cycle facilities for the accountancy of nuclear material such as plutonium. These techniques need to be improved and enhanced to meet the challenges of complex measurement items and future nuclear safeguards applications, for example; the non-destructive assay of spent nuclear fuel, high counting rate applications, small sample measurements, and Helium-3 replacement. At the same time simulation tools, used for the design of detection systems based on these techniques, are being developed in anticipation of future needs. This seminar will present the theory and current state of the practice of temporally correlated neutron counting. A range of future safeguards applications will then be presented in the context of research projects at Los Alamos National Laboratory.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analytical Laboratory Counting and Radiochemistry Group Equipment and Capabilities

The Analytical Laboratory at the Materials and Fuels Complex provides quality analytical results through a variety of instrumental methods. The work of the Counting and Radiochemistry Group focuses on several instrumental techniques: Gamma Spectrometry, Liquid Scintillation Counting, Gas Flow Proportional Counting, and Alpha Spectrometry. This talk will focus on an overview of the Counting and Radiochemistry's capabilities, and will briefly discuss some of the sample preparation methods currently in use by the group.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

500-MHz x-ray counting with a Si-APD and a fast-pulse processing system

We introduce a counting system of up to 500 MHz for synchrotron x-ray high-rate measurements. A silicon avalanche photodiode detector was used in the counting system. The fast-pulse circuit of the amplifier was designed with hybrid ICs to prepare an ASIC system for a large-scale pixel array detector in near future. The fast amplifier consists of two cascading emitter-followers using 10-GHz band transistors. A count-rate of 3.25x10{sup 8} s{sup -1} was then achieved using the system for 8-keV x-rays. However, a baseline shift by adopting AC-coupling in the amplifier disturbed us to observe the maximum count of 4.49x10{sup 8} s{sup -1}, determined by electron-bunch filling into a ring accelerator. We also report that an amplifier with a baseline restorer was tested in order to keep the baseline level to be 0 V even at high input rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Operation of gamma-ray microcalorimeters at elevated count rates using filters with constraints

Microcalorimeter sensors operated near 0.1 K can measure the energy of individual x- and gamma-ray photons with significantly more precision than conventional semiconductor technologies. Both microcalorimeter arrays and higher per pixel count rates are desirable to increase the total throughput of spectrometers based on these devices. The millisecond recovery time of gamma-ray microcalorimeters and the resulting pulse pileup are significant obstacles to high per pixel count rates. Here, we demonstrate operation of a microcalorimeter detector at elevated count rates by use of convolution filters designed to be orthogonal to the exponential tail of a preceding pulse. These filters allow operation at 50% higher count rates than conventional filters while largely preserving sensor energy resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗