Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRON MICROSCOPE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Self-consistent microscopic calculations for electron captures on nuclei in core-collapse supernovae

Calculations for electron capture rates on nuclei with atomic numbers between 𝑍 = 20 and 𝑍 = 52 are performed in a self-consistent finite-temperature covariant energy density functional theory within the relativistic quasiparticle random-phase approximation. Electron captures on these nuclei contribute most to reducing the electron fraction during the collapse phase of core-collapse supernovae. The rates include contributions from allowed (Gamow-Teller) and first-forbidden (FF) transitions, and it is shown that the latter become dominant at high stellar densities and temperatures. Temperature-dependent effects such as Pauli unblocking and transitions from thermally excited states are also included. The new rates are implemented in a spherically symmetric one-dimensional simulation of the core-collapse phase. The results indicate that the increase in electron capture rates, due to inclusion of FF transitions, leads to reductions of the electron fraction at nuclear saturation density, the peak neutrino luminosity, and enclosed mass at core bounce. The new rates reaffirm that the most relevant nuclei for the deleptonization situate around the 𝑁 = 50 and 82 shell closures, but, compared to previous simulations, nuclei are less proton rich. Here, the new rates developed in this work are available, and will be of benefit to improve the accuracy of multidimensional supernova simulations.

Electron & muon capture↗

Workflow Using a Cryogenic Coincident Fluorescence, Electron, and Ion Beam Microscope for Targeted Milling of Cells

This workflow enables lamella production targeting fluorescently labeled biological structures that are small (<1 μm in axial extent) and rare (1 copy per cell) using a cryogenic tri-coincident imaging platform. In conclusion, this platform integrates fluorescence microscopy, focused ion beam milling, and scanning electron microscopy at a single focal position and enables simultaneous fluorescence microscopy while milling.

Wang, Jue [California Institute of Technology (Cal↗

Your Clean Graphene is Still Not Clean

Researchers working with thin samples, such as monolayer graphene, are consistently struggling against contamination. Indeed, the problem of hydrocarbon contamination is known from the earliest days of electron microscopy and efforts to reduce this problem are ubiquitous to almost all high-vacuum experiments. Accurate knowledge of the behavior of such contamination is essential for electron beam (e-beam) based atomic fabrication, where it is aspired to select and control matter on an atom-by-atom basis. Here, the vexing question of hydrocarbon contamination on graphene is taken up. Image intensity is used to directly reveal the presence of diffusing hydrocarbons on ostensibly clean graphene. These diffusing hydrocarbons are previously inferred but not directly observed. Surprising dynamic variations of the concentration of these hydrocarbons impels questions about their origin. Here, some possible explanations are presented and some tentative conclusions are drawn. This work updates the conceptual model of “clean graphene” and offers refinements to the description of e-beam induced hydrocarbon deposition.

atomic fabrication↗

Improved representation of black carbon mixing structures suggests stronger direct radiative heating

Black carbon significantly influences the Earth system because of its strong solar radiation absorption. However, its direct radiative effect remains poorly understood in current climate models, partly because current climate models oversimplify the diverse structures formed when black carbon mixes with other atmospheric components. Here we show that incorporating more realistic, multi-mixing-structure representations of black carbon increases the direct radiative effect. We find that aged black carbon particles, with thicker coatings and higher embedded fractions, enhance the direct radiative effect more efficiently. Using machine learning alongside the Community Earth System Model, we show that the direct radiative effect at the top of the atmosphere in regions with heavy black carbon pollution is 31.6% greater when multi-mixing structures are considered. These findings highlight the importance of modeling complex mixing structures of particle-resolved black carbon to accurately capture their warming impacts on global atmosphere, particularly in highly polluted regions.

54 ENVIRONMENTAL SCIENCES↗

Experimental and theoretical investigation of the crystalline surface, film, and interface properties of antiperovskite Mn 3 GaN grown by molecular beam epitaxy on MgO(001)

Here, we present a study of the epitaxial growth, characterization, and theoretical modeling of thin film antiperovskite Mn 3 GaN, an antiferromagnetic material with kagome structure which is grown on MgO (001) substrates using N-plasma-assisted molecular beam epitaxy. Reflection high energy electron diffraction is used to assess the in-plane evolution of the film structure during growth, and the surface is investigated in-situ using scanning tunneling microscopy and Auger electron spectroscopy. These results are combined with precision measurements done ex-situ determining the film lattice constants using a combination of x-ray diffraction with reciprocal space mapping and scanning transmission electron microscopy. Overall, a uniform, homogeneous film with an atomically smooth vacuum surface and atomically sharp substrate interface is found having very small in-plane tensile strain and mild out-of-plane compressive strain. First-principles theoretical calculations are applied in order to ascertain the lowest energy models for both the Mn 3 GaN surface and the Mn 3 GaN/MgO film/substrate interface. Models including MnGa versus MnN surface layers and MnGa versus MnN interfacial layers are considered as functions of both the Mn and Ga chemical potentials. The predictions are discussed in comparison to the experimental results. The overall findings suggest that Mn 3 GaN on MgO(001) is a viable epitaxial film which can be further explored in connection with antiferromagnetic spintronics.

Density functional theory↗

Photovoltaic Cable Connectors: A Comparative Assessment of the Present State of the Industry

The consequences of failure for balance-of-systems components (such as photovoltaic (PV) cable connectors) include offline module string(s); low system voltage; arc, ground, insulation, and overtemperature faults; triggered fuse(s); system shutdown; and fire. The degradation modes for connectors are studied here through an industry survey and its subsequent examination, which are compared with field-degraded specimens. A total of 117 specimens were obtained from a variety of locations and climates or accelerated tests. A failure analysis for connectors from PV installations was developed (and applied to 54 specimens), including nondestructive examinations (photography, a custom resistance-current scan, and X-ray computed tomography) and destructive examinations (featuring milling of the external plastic, extraction of the internal convolute spring, and potting and polishing in cross section). Surface and through-thickness composition of the metal pins and springs was quantified using scanning electron microscopy with energy-dispersive X-ray spectroscopy. Fourier transform infrared spectroscopy was used to verify the base polymer materials and compare the chemical structure of the connector body, bushing, end nut, and o-ring. Thermogravimetric analysis and differential scanning calorimetry were used to further verify the degradation of the same polymeric components.

cable connectors↗

Instrumentation and Samples (CRADA Final Report)

Instruments which are categorized as shared user instruments at the National Laboratory of the Rockies (NLR) will be utilized for ongoing technical work. Samples will be provided by University of Colorado Boulder (CU) and thus no need for materials at NLR is anticipated.

(Ga1- xZnx)(N1-xOx)↗

Advanced Interactive 3D Visualization Tool for Customizable Analyses of Tomography Datasets in Material Science

Current methods for visualizing and analyzing 3D tomography datasets in materials science often lack the interactivity and depth required for detailed structural insights. This limitation restricts a researchers' ability to accurately interpret complex data, which is critical for advancing material innovations and understanding structural properties. To address this issue, we have developed a novel, web-based interactive 3D visualization and analysis tool from the Trame framework that offers customizable features to enhance data interpretability. The tool allows users to adjust parameters such as visible range, slice planes, data rotation, and layering, providing a more detailed and dynamic view of complex structures. Its user-friendly web interface increases the accessibility and ease of use for both novice and experienced researchers, to visualize large volumetric datasets. The tool supports a diverse range of data formats, making it versatile for various research applications. Unique capabilities include real-time data manipulation, automated feature detection, context-sensitive feedback, and real-time volume calculations and distributions per sliced region or layer, alongside the ability to quickly generate high-quality screenshots and videos for presentations and reports. These advancements offer a comprehensive solution for enhanced 3D data exploration, significantly improving the analysis process and communication of results in materials science.

36 - MATERIALS SCIENCE↗

Web-based Preprocessing and Visualization of 3D FIB Tomography Data for Nuclear Fuel Characterization

Three-dimensional (3D) focused ion beam (FIB) tomography enables reconstruction of internal nuclear fuel features that can't be fully evaluated through surface imaging alone. This capability supports characterization of fuel constituents and defects under thermal and irradiation conditions relevant to microreactor development. However, large tomography datasets can create data-handling, loading, and visualization challenges, especially when image-stack preparation and file conversion must be completed with separate tools. The Computational Ultraspatial Tomography Toolkit for High-Resolution Object Analysis Tools (CUTTRHOAT) is an open-source web application being developed to display FIB tomography datasets available through the Nuclear Research Data System (NRDS). The current alpha version requires prepared HDF5 datasets and has limited integrated data-preparation capabilities. This project improves CUTTHROAT by adding dataset-folder selection, automatic input detection, dataset scanning, missing-slice identification, blank-slice insertion, and image-stack-to-HDF5 conversion. Two applications will be compared: the baseline CUTTHROAT alpha workflow and the updated application containing the integrated data-handling and preprocessing functions. Evaluation will consider dataset detection accuracy, conversion success, loading time, rendering responsiveness, application stability, and user interaction. Preliminary results demonstrate successful loading of existing HDF5 files and converted image stacks, while testing also identified performance reductions caused by excessive blank-slice generation. The updated workflow reduces reliance on external preparation tools and supports more direct movement from image stacks to color-code 3D visualization. Future work includes refining missing-slice handling, integrating additional preprocessing functions, like a denoising feature, parsing TIFF metadata for automatic voxel scaling, and adding manual X, Y, and Z voxel-spacing inputs for PNG and JPEG.

36 - MATERIALS SCIENCE↗

The Auger Radioisotope Microscope: an instrument for characterization of Auger electron multiplicities and energy distributions

We describe a new instrument, the Argonne Auger Radioisotope Microscope (ARM), capable of characterizing the Auger electron (AE) emission of radionuclides, including candidates relevant in nuclear medicine. Our approach relies on event-by-event ion–electron coincidence, time-of-flight, and spatial readout measurement to determine correlated electron multiplicity and energy distributions of Auger decays. We present a proof-of-principle measurement with the ARM using x-ray photoionization of stable krypton beyond the K-edge and identify a bifurcation in the electron multiplicity distribution depending on the emission of K-LX electrons. Extension of the ARM to the characterization of radioactive sources of AE emissions is enabled by the combination of two recent developments: (1) cryogenic buffer gas beam technology to introduce Auger emitters into the detection region with well-defined initial conditions, and (2) large-area micro-channel plate detectors with multi-hit detection capabilities to simultaneously detect multiple electrons emitted in a single decay.

Auger emitters↗

Microscopic Origin of Twist-Dependent Electron Transfer Rate in Bilayer Graphene

Using molecular simulation and continuum dielectric theory, we consider how electrochemical kinetics are modulated by the twist angle in bilayer graphene electrodes. By establishing a connection between the twist angle and the screening length of charge carriers within the electrode, we investigate how tunable metallicity modifies the statistics of the electron transfer energy gap. Constant potential molecular simulations show that the activation free energy for electron transfer increases with screening length, leading to a non-monotonic dependence on the twist angle. Here, the twist angle alters the density of states, tuning the number of thermally accessible channels for electron transfer and the reorganization energy by affecting the stability of the vertically excited state through attenuated image charge interactions. Understanding these effects allows us to express the Marcus rate of interfacial electron transfer as a function of the twist angle in a manner consistent with experimental observations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Temperature-induced degradation of GaN HEMT: An in situ heating study

High-power electronics, such as GaN high electron mobility transistors (HEMTs), are expected to perform reliably in high-temperature conditions. This study aims to gain an understanding of the microscopic origin of both material and device vulnerabilities to high temperatures by real-time monitoring of the onset of structural degradation under varying temperature conditions. This is achieved by operating GaN HEMT devices in situ inside a transmission electron microscope (TEM). Electron-transparent specimens are prepared from a bulk device and heated up to 800 °C. High-resolution TEM (HRTEM), scanning TEM (STEM), energy-dispersive x-ray spectroscopy (EDS), and geometric phase analysis (GPA) are performed to evaluate crystal quality, material diffusion, and strain propagation in the sample before and after heating. Gate contact area reduction is visible from 470 °C accompanied by Ni/Au intermixing near the gate/AlGaN interface. Elevated temperatures induce significant out-of-plane lattice expansion at the SiNx/GaN/AlGaN interface, as revealed by geometry-phase GPA strain maps, while in-plane strains remain relatively consistent. Exposure to temperatures exceeding 500 °C leads to almost two orders of magnitude increase in leakage current in bulk devices in this study, which complements the results from our TEM experiment. The findings of this study offer real-time visual insights into identifying the initial location of degradation and highlight the impact of temperature on the bulk device’s structure, electrical properties, and material degradation.

36 MATERIALS SCIENCE↗

Calibrating cryogenic temperature of TEM specimens using EELS

Cryogenic Scanning/Transmission Electron Microscopy has been established as a leading method to image sensitive biological samples and is now becoming a powerful tool to understand materials' behavior at low temperatures. However, achieving precise local temperature calibration at low temperatures remains a challenge, which is especially crucial for studying phase transitions and emergent physical properties in quantum materials. In this study, we employ electron energy loss spectroscopy (EELS) to measure local cryogenic specimen temperatures. Here we use the temperature-dependent characteristics of aluminum's bulk plasmon peak in EEL spectra, which shifts due to changes in electron density caused by thermal expansion and contraction. We successfully demonstrate the versatility of this method by calibrating different liquid nitrogen cooling holders in various microscopes, regardless of whether a monochromated or non-monochromated electron beam is used. Temperature discrepancies between the actual temperature and the setpoint temperatures are identified across a range from room temperature to 100 K. This work demonstrates the importance of temperature calibrations at intermediate temperatures and presents a straightforward, robust method for calibrating local temperatures of cryogenically-cooled specimens in electron microscopes.

36 MATERIALS SCIENCE↗

Reduced trap state density in AlGaN/GaN HEMTs with low-temperature CVD-grown BN gate dielectric

In this Letter, low-temperature (400 °C) chemical vapor deposition-grown boron nitride (BN) was investigated as the gate dielectric for AlGaN/GaN metal–insulator–semiconductor high electron mobility transistors (MISHEMTs) on a Si substrate. Comprehensive characterizations using x-ray photoelectron spectroscopy, reflection electron energy loss spectroscopy, atomic force microscope, high-resolution transmission electron microscopy, and time-of-flight secondary ion mass spectrometry were conducted to analyze the deposited BN dielectric. Compared with conventional Schottky-gate HEMTs, the MISHEMTs exhibited significantly enhanced performance with 3 orders of magnitude lower reverse gate leakage current, a lower off-state current of 1 × 10−7 mA/mm, a higher on/off current ratio of 108, and lower on-resistance of 5.40 Ω mm. The frequency-dependent conductance measurement was performed to analyze the BN/HEMT interface, unveiling a low interface trap state density (Dit) on the order of 5 × 1011–6 × 1011 cm−2 eV−1. This work shows the effectiveness of low-temperature BN dielectrics and their potential for advancing GaN MISHEMTs toward high-performance power and RF electronics applications.

Physics↗

Dynamic mode decomposition of nonequilibrium electron-phonon dynamics: accelerating the first-principles real-time Boltzmann equation

Abstract Nonequilibrium dynamics governed by electron–phonon ( e -ph) interactions plays a key role in electronic devices and spectroscopies and is central to understanding electronic excitations in materials. The real-time Boltzmann transport equation (rt-BTE) with collision processes computed from first principles can describe the coupled dynamics of electrons and atomic vibrations (phonons). Yet, a bottleneck of these simulations is the calculation of e –ph scattering integrals on dense momentum grids at each time step. Here we show a data-driven approach based on dynamic mode decomposition (DMD) that can accelerate the time propagation of the rt-BTE and identify dominant electronic processes. We apply this approach to two case studies, high-field charge transport and ultrafast excited electron relaxation. In both cases, simulating only a short time window of ~10% of the dynamics suffices to predict the dynamics from initial excitation to steady state using DMD extrapolation. Analysis of the momentum-space modes extracted from DMD sheds light on the microscopic mechanisms governing electron relaxation to a steady state or equilibrium. The combination of accuracy and efficiency makes our DMD-based method a valuable tool for investigating ultrafast dynamics in a wide range of materials.

36 MATERIALS SCIENCE↗

The ABCs of phase retrieval: Connecting the acronyms of scanning transmission electron microscopy

High-resolution scanning transmission electron microscopy (S/TEM) is an indispensable tool for characterizing the structure and properties of materials down to the atomic scale. Conventional S/TEM imaging, however, is limited by the phase problem, whereby the phase of the electron exit wave is lost upon detection. Recent advances in diffractive imaging and 4D-STEM have enabled a range of phase-retrieval techniques that computationally reconstruct the missing information encoded in the phase of the transmission function. These approaches offer improved dose efficiency and enhanced sensitivity to weakly scattering signals, extending quantitative imaging to beam-sensitive materials composed of light elements. In this work, we introduce the phase problem in electron microscopy and survey the diverse landscape of phase-retrieval techniques used in the field. Despite their many acronyms and algorithmic variations, these techniques share a common physical and mathematical foundation. We present a unified framework that connects these seemingly distinct methods, from parallax imaging and tilt-corrected bright-field (tcBF-STEM), to aberration-corrected bright-field (acBF-STEM), optimum bright-field (OBF-STEM) and single-sideband (SSB) ptychography, as well as first-moment integrated center of mass techniques (iCOM) and iterative ptychographic algorithms. Based on these insights, we discuss the opportunities and practical limitations of applying these methods across different materials systems, detector designs, and microscope configurations.Graphical abstractRepresentative electron microscopy configurations used for phase retrieval and diffractive imaging in S/TEM: (a) Zernike phase-contrast transmission electron microscopy (TEM), (b) small-convergence-angle four-dimensional scanning transmission electron microscopy (4D-STEM) for nanobeam-based phase reconstruction methods, and (c) large-convergence-angle 4D-STEM for ptychographic and related diffractive imaging techniques reviewed in this work.

36 MATERIALS SCIENCE↗

Probing electromagnetic nonreciprocity with quantum geometry of photonic states

Reciprocal and nonreciprocal effects in dielectric and magnetic materials provide crucial information about the microscopic properties of electrons. However, experimentally distinguishing the two has proven to be challenging, especially when the associated effects are extremely small. To this end, we propose a contactless detection using a cross-cavity device where a material of interest is placed at its center. We show that the optical properties of the material, such as Kerr and Faraday rotation, or birefringence, manifest in the coupling between the cavity's electromagnetic modes and in the shift of their resonant frequencies. By calculating the dynamics of a geometrical photonic state, we formulate a measurement protocol based on the quantum metric and quantum process tomography that isolates the individual components of the material's complex refractive index and minimizes the quantum mechanical Cramér-Rao bound on the variance of the associated parameter estimation. Our approach is expected to be applicable across a broad spectrum of experimental platforms including Fock states in optical cavities, or coherent states in microwave and THz resonators. Published by the American Physical Society 2025

Petrides, Ioannis (ORCID:0000000174842444)↗

Semiconductor‐Electrocatalyst Contacts: Theory, Experiment, and Applications to Solar Water Photoelectrolysis

The goal of the work supported by this program was to use new types of photoelectrochemical experiments, supported by simulation and theory, to develop an improved microscopic picture of electron transfer in combined semiconductor|catalyst|solution (sem|cat|sol) systems. An emphasis was placed on developing techniques which can directly characterize electronic interfacial phenomena without first assuming a junction model. We then aimed to illustrate the design principles that enhance interfacial processes and enable high-efficiency devices. Our work thus provides deep insight into the processes that, in general, use light to drive chemical reactions.

14 SOLAR ENERGY↗